KYO 100 / KYO 300 � AUGEN S.A.� chée de Bruxelles 408� B6040 - Charleroi (Jumet) TVA : 423145 969� RC Charleroi n° 137.029� Fortis : 001-1611819-46� � URL : http://www.augen.be/� Tél. : +32 (0)71 35 45 33� Fax. : +32 (0)71 35 47 82� � Agréation INCERT : C-4006� Agréation UPEA AIV 017� Ministère de l'intérieur 20046930� Entreprise agréée classe 1 Security Engineering

This system can be programmed using the respective (KYO100 or KYO300) Software Application 1.0 or higher.

Installation of the system must be carried out strictly in accordance with the instructions described in this manual, and in compliance with the local laws and bylaws in force. The KYO100 and KYO300 Control panels have been designed and manufactured to the highest standards of quality and performance. The KYO300 and KYO100 Control panels have no user-friendly components, therefore, should be serviced by authorized personnel only. BENTEL SECURITY shall not assume the responsibility for damage arising from improper application or use. The manufacturer recommends that the installed system should be completely tested at least once a month. Hereby, Bentel Security, declares that KYO300 and KYO100 Control panels comply with the essential requirements and other relevant provisions of Directive 1999/5/EC. The complete R&TTE Declaration of Conformity can be found at www.bentelsecurity.com/dc.html. The KYO300 and KYO100 Control panels comply with CEI 79/2 2nd Ed. 1993 - Performance Level II. The KYO300 and KYO100 Control panels, all their accessories and functions, except those listed below, and unless otherwise specified (see notes marked A), are IMQ Security Systems Grade II Listed. The following accessory items and facilities ARE NOT IMQ listed: OMNIA/4R 4 Relay Module ASD10 Wireless Smoke Detector B-MOD Teleservice Modem B-MOD/RX Teleservice and Telemonitoring Modem TELESERVICE Facility TELEMONITORING Facility FIRE CONTROL Facility BENTEL SECURITY srl. reserves the right to change the technical specifications of these products without prior notice. 2

About the System

5 General Features 6 The System and Accessories 6 Technical Specifications 7 Accessory Items 8 Differences between KYO 300 and KYO 100 8 IDENTIFICATION OF PARTS 9 About the Control panel 9 MIA-D and Alison-DV Keypads 11 Readers and Digital Keys 13 Input and Output Expanders 14 INSTALLING 15 Mounting the Main Unit 15 Connecting Keypads 15 Connecting Readers 16 Connecting Input and Output Expanders 16 The Terminals 17 Main Unit 17 BPI Peripherals 18 The Wiring 19 Connecting BPI Bus Devices 19 BPI bus Wiring Limitations 21 Connecting Detectors 21 Connecting Motion Detectors 22 Glass Break Detectors 24 Connecting Fire Detectors 24 Connecting Alarm Signalling Devices 24 Supervised Outputs (KYO 300 only) 26 Connecting Tamper Terminals 26 Connecting the Telephone Line 28 Connecting a Power Supply 28 Connecting the Mains 29 Auto-configuration 29 RAM Battery (see page 11) 29 Thermal Probe 30 PROGRAMMING 31 Configuration (Enrolling Devices) 31 Keypads Page 32 LED Keypads 33 Input Expanders 33 Output Expanders 33 Readers 33 Power sta 34 Accessories 35 Hardwired Zones 36 Type 37 Command 38 Attributes 39 Balance Type 39 Threshold 40 Inactivity 40 Cycles 41 Partitions 41 Sensitivity 41 Voice Messages 42 Zone in AND Mode 42 Wireless 43 Replacing Wireless Devices 44 Enrolling Wireless Devices 44 Unenrolling Wireless Devices 44 Outputs 44 Type 45 Polarity 45 Attributes 46 Associated Timer 46 Times 46 Oscillation 47 Cycles 47 Events 47 Partitions 47 Telephone 49 Answer 49 Dialling 49 Answering Machine 50 Dialler 51 Dialler book 51 Send Message after ... 51 Messages 52 Options 52 Actions 52 Digital Communicator 53 Actions 54 Auxiliary Communicator (KYO 300 only) 55 Voice Messages 56 Compound Messages 56 Teleservice 57 Enable Test Event 57 Installer Maintenance 58 Central Station Maintenance 58 Logger – Events setup 59 Events-Actions 59 Telephone action priority 59 Colours 60 Events Details 60 Clear 61 Find 61 KYO 300-KYO100 3

Scheduler - Arming

76 Type Description 76 Models 76 Options 77 Examples 77 Scheduler - Timers 78 Type Description 78 Models 79 Options 79 Keypad Codes - User 81 Enable on Partitions 82 Associated Timer 82 User menu access 83 Father PIN 83 New PIN 83 Code Type 83 Enable on LCD Keypad 83 Enable on LED Keypad 83 Programming 83 Codes - Installers 83 Lost Installer Codes 84 Codes - Code Types 84 User Codes 85 Installer Codes 86 Digital keys 87 Allowed Operations 87 Attributes 87 Enable on Key Reader 87 Clock 88 On-site downloading 88 Remote Downloading 89 APPENDIX 91 K3-VOX Voice Board 91 Features 91 Identification of Parts 91 Installation 91 Expanding the Listen-in facility 91 Manual selection 92 Auto-select mode 92 Manual and Auto-select mode 93 K3-PRT Printer Interface 93 Identification of Parts 93 Connecting the Printer 93 Installation instructions 93 K3-AuxCom Auxiliary Communicator 94 Installation 94 VectorRX Receiver 94 Identification of Parts 94 Choosing a Mounting Location 95 Mounting the Receiver 95 Connecting the Receiver 95 Technical Specifications 95 Reset default 95 Reporting Formats 96 TELIM 96 Contact ID 96 SIA 96 New features 96 KYO300 1.10 96 KYO 300 Rev. 1.20 and KYO 100 Rev. 1.20 100 4

About the System

This manual can be used with KYO 300 and KYO 100 Con- trol panels. The term “Control panel” or “System” has been used in the parts where the functions and operating modes are common to both systems. However, in the parts where the functions and operating modes differ, the respective Control panel has been specified. The full-featured KYO 300 and KYO 100 security systems have been especially designed to satisfy all security needs, from residential to advanced industrial applica- tions. The objective of the KYO300 and KYO 100 is to make end-user operation simple and help the Installer im- prove efficiency. This is achieved by reduced complex- ity software and firmware, and remote programming and diagnostic facilities. This system provides impressive application flexibility and many interesting features such as monitoring facili- ties and telephone access (refer to “Telephone func- tions”). KYO 300 has 8 Input zones expandable to 312, and 6 Outputs expandable to 118, whereas KYO 100 has 8 Input zones expandable to 168, and 4 Outputs expand- able to 116. Partitions KYO300 manages 32 independent Parti- tions, whereas the KYO 100 manages 16 — all with Stay/Away control. Each Partition (group of zones) can be programmed with its own Entry/Exit and Auto-Arm/Disarm Times, etc., and can be controlled by digital Keys/Cards, Codes and/or Input zones. Events and Actions KYO300 manages over 3000 events, whereas the KYO 100 manages over 2000. The factory default settings have been purpose pro- grammed to require few or no changes for standard ap- plications. However, the programming flexibility of the Events and Actions (Output, Digital communicator and Voice Dialler Actions) will allow you to customize the system to suit requirements. Telephone Functions The Telephone Communicator manages 50 telephone number. Up to 8 telephone numbers can be assigned to the Digital Communicator. Each Communicator number can have its own Cus- tomer Code and Reporting format (usually assigned by the Central station). The Bentel Security Suite Software and B-Mod Mo- dem (accessory items) reduce on-site time to a mini- mum by allowing you to provide Teleservice (on-line Customer enquiry and assistance facilities). The Teleservice facility can also be used for uploading, downloading and diagnosis. Up to 4 telephone numbers can be assigned to this facility. Voice Board The K3-VOX Voice Board (accessory item) manages 62 recordable Voice messages, and 32 telephone numbers for the Answerphone, Dialler, Memo and Ambient-sound recording facilities. Voice communications to and from the Control panel al- low operations such as: Listen-in; Talk/Listen-in (2Way Audio); Input status enquiry (with Voice answer); Re- mote control of appliances (Turn ON/OFF); Arm/Disarm Partitions; Alarm Reset and Inhibit Calls. Access to all the “over-the-phone” features requires a Telephone Access Code — which can be disabled im- mediately after use. Scheduler The Scheduler can be setup to Arm/Disarm Partitions automatically (on a daily or weekly basis), and to control 64 daily timer events for KYO 300, and 32 daily timer events 32 KYO 100. Wireless Devices This system supports the VectorRX Receiver (accessory item). The VectorRX Receiver ac- cepts up to 32 Wireless devices, such as: PIR Motion Detectors (AMD10); Magnetic Contacts (AMC10); Glass break Detectors (AGB10); Smoke Detectors (ASD10), and up to 16 Wireless Keys (ARC10). Programming This system can be programmed from the Keypad, or via the KYO300 Software Application and a computer. The Software Application (runs under Windows) provides real-time supervisory facilities (via connection to an RS232 Interface or Teleservice), and will allow you to make the fullest use of all the system features. KYO 300-KYO100 INTRODUCTION 5

The KYO 300 Control panel

� Up to 312 Alarm zones: 8 zones on the Main Board; 192 on 32 Input Expanders (6 zones per expander); 64 on 32 MIA-D Keypads (2 zones per keypad); 16 on 16 ALISON/32LP LED Keypads (1 zone per key- pad) and 32 Wireless zones � Up to 118 Outputs: 6 Outputs on the Main Board (3 Relays and 3 Open-Collectors); 96 on 16 Output Ex- panders (6 outputs per expander) and 16 on ALISON/32LP LED Keypads � Up to 32 backlit LCD Keypads for system control � Up to 32 Digital Key/Card Readers � 195 User Codes with programmable ‘View’ option, priority and functions � 10000 Event Logger with date and time details The KYO 100 Control panel � Up to 168 Alarm zones: 8 zones on the Main Board; 96 on 16 Input Expanders (6 zones per expander); 16 on 16 ALISON-S LCD Keypads (1 zone per key- pad); 16 on 16 ALISON/32LP LED Keypads (2 zones per keypad) and 32 Wireless zones � Up to 116 Outputs: 4 Outputs on the Main Board (2 Relays and 2 Open-Collectors); 96 on 16 Output Ex- panders (6 outputs per expander) and 16 on ALISON/32LP LED Keypads � Up to 16 backlit LCD Keypads for system control � Up to 16 Digital Key/Card Readers � 97 User Codes with programmable ‘View’ option, pri- ority and functions � 1500 Event Logger with date and time details Features common to KYO 300 and KYO 100 � Up to 8 power stations � 4 wire Bus (protected against short-circuit) for pe- ripherals � Dual branch bus for protection against tamper � Programmable Balance, Operating mode and Alarm type — for all zones � Input zones can be programmed to send specific commands to the Control panel � Outputs can be programmed as bistable or cyclic with programmable cycle times and standby status � 32 programmable partitions — each with own zones, keypads, readers, outputs and times � 195 User Codes with programmable priority and functions � 500 programmable Digital Keys/Cards � 16 character labels (ID) for the partitions, zones, keypads, readers, codes, keys/cards, etc. — the as- signed label will be shown on the keypad display dur- ing the user operations � 10000 event logger — provides details of the opera- tion type, time and user � RS232 Interface for system programming and moni- toring � Software (runs under Windows) for Control panel Programming, Teleservice and Monitoring Telephone Facilities � Pulse and Touch-tone (DTMF) dialling � 50 Telephone numbers for Telemonitoring, Teleservice and Voice Calls � Integrated Digital Communicator: supports Pulse, DTMF and FSK Reporting formats � 6 Instant Alarm calls from each Keypad � Programmable Test call � Double Call � Line sharing with other Telephone devices � 1200 baud FSK integrated Modem for Teleservice management Telephone facilities with K3-VOX optional Voice Board � Dialler facility: sends recordable voice messages to up to 32 Telephone numbers � Remote Inquiry with Voice answer (requires Access Code) � Remote control of Outputs, Arm/Disarm operations, Alarm Reset (requires Access Code) � Remote Listen-in and multipoint Telephone commu- nication (Talk/Listen-in) � Answerphone facility Scheduler Facility � Daily, Weekly and Monthly scheduling � Holiday and Summertime changeover management � Overtime and Arming delay management � 4 Arm and 4 Disarm operations per day per Partition � 64 independent daily Timer events for KYO 300 and 32 for KYO 100 Event print-out using optional K3-PRT Board � Prints Events on parallel printer � Real-time and/or Event Logger printout from speci- fied date to last Event � Event filter The System and Accessories The Control panel The Control panel is the core of the system. It has 8-zones (KYO 300 expands to 312; KYO 100 to 168), 6 Outputs (KYO 300 expands to 118; KYO 100 to 116) and a 5A Switching Power Supply (3A for KYO 100). Expanders The Control panel manages up to 32 six zone M-IN/6 Input Expanders (16 for KYO 100) and up to 16 M-OUT/6 Output Expanders (6 Open-Collector Outputs per Expander). Control Devices The KYO 300 accepts up to 32 ECLIPSE and/or PROXI Digital Key/Card Readers and/or 16 ALISON/32LP LED Keypads, and/or up to 32 MIA-D and/or ALISON-DV LCD Keypads. The KYO 100 accepts up to 16 ECLIPSE and/or PROXI Digital Key/Card Readers, and/or up to 16 ALISON-S LCD Keypads, and/or up to 16 ALISON/32LPLED Key- pads. The operating principles of the ECLIPSE and PROXI Readers are the same, except: � ECLIPSE Readers accept SAT Keys only and are for indoor use only (unless mounted inside weather- proof boxes); 6

� PROXI Readers have weather strips, and can be in-

stalled indoors or outdoors (IP34 Protection Class) and accept SAT Keys and PROXI-cards. � ECLIPSE and PROXI Systems operate without con- tacts, therefore, are highly resistant to oxidization and wear. � Alison/32LP is a 32 LED Keypad with built-in pro- grammable Proximity Reader function. The operating principles of the MIA-D and ALISON-DV Keypads are the same, except: � MIA-D Keypads have larger displays, 2 on-board zones and 3 sets of Function keys for manual activa- tion of Alarm status; � ALISON-DV Keypads have smaller cases, 1 on-board zone, and an integrated Loudspeaker and Microphone for use with the K3-VOX. � ALISON-S is identical to ALISON-DV but does have a microphone or loudspeaker. K3-VOX The K3-VOX Voice board (accessory item) can be used for Voice Messages, and Telephone Ac- cess. K3-PRT The K3-PRT Printer Interface (accessory item) can be used for real-time and/or Event Logger printout. Power station The Power station has been especially designed for Security system applications. The tamper protected box (protected against delinquency and snatch) can house a battery for power backup during black-out. This control panel supports up to eight BXM12-B/30 3A Power Stations and/or BXM12-B/50 5A Power stations. Management Software The management software (runs under Windows) provides full Programming, Cus- tomer Database and real-time Supervisory facilities, and will allow you to make the fullest use of all the sys- tem features. The B-Mod Modem The B-Mod Modem will allow you to Upload/Download from/to the remote system and carry out Teleservice operations (remote diagnosis and maintenance). The B-Mod/RX will allow you to Up- load/Download from/to the remote system and carry out Teleservice and Telemonitoring (send/receive real-time transmissions). Technical Specifications The following table contains the technical Specifica- tions of the KYO300. Voltage 230 V~ ±10% 50/60 Hz Maximum current draw 0.9 A Insulation Class Class I Power Supply/Battery Charger 13.8 V_ ±1% 5 A (3A for KYO 100) Maximum Current available for Peripherals 3.5 A (1.7A for KYO 100) Battery (Brand and Type) 12 V - 7 Ah or 12 V - 17 Ah YUASA NP 7-12 FR or NP 17-12 FR or similar Case Flame Class UL94-V2 or higher Random Digital Key/Card Codes 4.295.000.000 Operating Temperature 5 ÷ 40 °C Dimensions (W x H x D) 339 x 488 x 108 mm Weight (without battery) 5.55 Kg The following chart shows the current draw (I (mA) col- umn) and size of the accessory components. Component I (mA) Size (WxHxD mm) KYO300-KYO100 Main Board 250 — MIA-D Keypad 50 164 x 133 x 44 ALISON-DV Keypad 40 143 x 115 x 38 ECLIPSE Reader 30 — PROXI Proximity Reader 30 78 x 108 x 22 ALISON/32LP LED Keypad 70 142 x 115 x 35 M-IN/6 Input Expander 20 108 x 101 x 34 M-OUT/6 Output Expander 20 Omnia4R 4 Relay Module 120 K3-VOX + VOX-REM Voice Board + Microphone -Loudspeaker Board 20 — K3-AuxCom Auxiliary Communicator (KYO 300 only) 20 — K3-PRT Printer Interface 40 — BXM12-B/30 Power Station 10 — BXM12-B/50 Power Station 10 — VectorRX Receiver 50 146 x 290 x 28 KYO 300-KYO100 INTRODUCTION 7

� Accessory Items

The following chart shows the Control panel accessory items, and certifications. MIA-D A Backlit LCD Keypad (2 Inputs) ALISON-DV A Backlit LCD Keypad (1 Input) with Microphone + Loudspeaker ALISON-S Backlit LCD Keypad (1 Input) with- out Microphone + Loudspeaker ALISON/32LP 32 LED Keypad (1 Input and 1 Output) M-IN/6 A 6 Input Expander Module M-OUT/6 A 6 Output Expander Module K3-VOX A Voice Board K3-AUXCOM A Auxiliary communicator (KYO300 only) K3-PRT A Printer Interface VOX-REM A Microphone + Loudspeaker for Listen-in facility MINI-BOX A Microphone + Loudspeaker box PROXI A Proximity Reader PROXI-CARD A Proximity Card ECLIPSE3ABI A Flush mounting, Contactless Reader— AVE ECLIPSE3AN A Flush mounting, Contactless Reader— AVE noir ECLIPSE3DEL A Flush mounting, Contactless Reader— DELTA ECLIPSE3DN A Flush mounting, Contactless Reader— DELTA noir ECLIPSE3GE A Flush mounting, Contactless Reader— GEWISS ECLIPSE3GGE A Flush mounting, Contactless Reader— GEWISS noir ECLIPSE3GP A Flush mounting, Contactless Reader— GEWISS playbus ECLIPSE3IN A Flush mounting, Contactless Reader— TICINO international ECLIPSE3LGT A Flush mounting, Contactless Reader— TICINO light ECLIPSE3MA A Flush mounting, Contactless Reader— TICINO magic ECLIPSE3VI A Flush mounting, Contactless Reader— VIMAR idea ECLIPSE3VIB A Flush mounting, Contactless Reader— VIMAR light SAT A Digital Key, Contactless—for Key and Proximity Readers OMNIA/4R — 4 relay Module for Output Expanders BXM12-B/30 — 3 A Power Station BXM12-B/50 — 5 A Power Station B-MOD — Teleservice Modem B-MOD/RX — Teleservice and Telemonitoring Modem CVSER/9F9F — Serial cable for computer link ADSER/9M25F — 25 pin adapter for serial ports SECURITYSUITE A Management Software VECTOR/RX A Wireless Receiver AMD10 A Wireless PIR Detector AMC10 A Wireless Magnetic Contact ARC10 A Wireless Digital Key ASD10 — Wireless Smoke Detector ASNC — Snatch Microswitch for Keypads ASNC-MINI — Snatch Microswitch for Proximity Readers KST — Thermal Probe � Differences between KYO 300 and KYO 100 KYO 300 KYO 100 Readers 32 16 Expander-In 32 16 Expander-Out 16 16 Power Stations 8 8 LCD Keypads 32 16 LED Keypads 16 16 Compatible LCD Keypads MIA-D and ALISON-DV ALISON-S RX Wireless Receiver Yes Yes Zones on-board 8 8 Zones on Keypad 64+16 16+16 Zones on Exp-In 192 96 Wireless Zones 32 32 Total Zones 312 168 Supervised Relay Outputs 3 No On-board Relay Outputs 3 2 Open-drain Outputs on-board 3 2 Open-drain Outputs on- Exp-out 96 96 Total Outputs 102+16 100+16 Partitions 32 16 Total User Codes 195 97 DTMF User Codes 64 (out of 195) 16 (out of 97) Installer Codes 5 3 User Code Types 16 16 Installer Code Types 3 3 Keys/Cards 500 500 Keyfobs (Wireless Keys) 16 16 Events in Logger 10000 1500 Total Events-Actions 3391 2035 Customizable Events 32 32 Timers 64 32 Fuses 10 5 Messages 62 62 K3/VOX Voice Board Yes Yes K3/PRT Printer Board Yes Yes K3-AUXCOM Yes No Numbers in Phonebook 50 50 Telephone Dialler Actions 50 50 Digital Communicator Actions 100+100 100+100 8

IDENTIFICATION OF PARTS

Please read this section carefully to get an overall view of the main components of the system and LED signals. The numbers in boldface (used in this text) refer to the descriptions in the tables and figures in this section. The components are generally numbered in clockwise order. The outlined numbers refer to the common hard- ware components of the BPI devices and are described once only — when first encountered. � About the Control panel Figure 1 shows the maximum configuration of the KYO300, (Figure 2 KYO100) therefore, some of the components may not be present on this system. KYO 300-KYO100 IDENTIFICATION OF PARTS 9 No. DESCRIPTION 1 Frontplate screws (2) 2 Loudspeaker (supplied with K3-VOX Voice Board) 3 Tamper Microswitch 4 Main Board (see fig. 3) 5 Backplate anchor screw locations (4x Ø 5 mm) 6 K3-VOX Voice board (accessory item) 7 K3-AuxCom Auxiliary Communicator (acces- sory item for KYO 300 only) 7a K3-PRT Printer Interface (accessory item) 8 Switching Power Supply (see fig. 4) 9 Thermal probe (accessory item) 10 Housing for 12V – 17Ah max. Battery (not sup- plied) 11 Cable entry 12 Snatch Microswitch 13 Snatch bracket 14 Auxiliary board for future use 15 K3-PRT Printer interface connector 16 Detachable Terminal board for Telephone line connection 17 K3-VOX Voice Board connector 18 Auxiliary Communicator Jumper: // = Disabled (at default) oo = Enabled 19 Auxiliary Communicator connector 20 Flash Memory chip 21 Memory Jumper (M) — if inserted, it will allow the system to save the programmed parameters during black-out: oo = parameters will be deleted (at default); // = parameters will be stored No. DESCRIPTION 22 Switching power Supply connector (connected) 23 RAM chip battery holder 24 Serial Port RS232 25 RESET LED: OFF = Microprocessor OK ON = Microprocessor resetting 26 BPI LED: OFF = BPI Bus OK ON = BPI Bus Trouble 27 MICRO LED: OFF or ON = Microprocessor blocked Flickering = Microprocessor OK 28 MAINS LED: ON = Control panel powered by Mains (230 V); OFF = Mains Failure—the Control panel will be powered by the backup Battery during blackout 29 Fuse — protects KEYBUS [RED] terminal 30 Switching Power Supply Output control (con- nected) 31 Thermal probe connector 32 Detachable Terminal board (KEY BUS) for VectorRX Receiver connection 33 Detachable Terminal board (BPI bus) for BPI device connections 34 Fuse—protects BPI2 bus [+] terminal (F 3.15A 250V) 35 Fuse—protects BPI1 bus [+] terminal (F 3.15A 250V) 36 Fuse—protects [+F1] terminals (F 3.15A 250V) 37 Fuse—protects [+F] terminals (F 3.15A 250V) 38 connectorforMIA-D,ALISON-DVorAlison-SKeypad 39 Microprocessor 40 Detachable Terminal board for Tamper Line and Input device connections (Detectors, etc.) 41 Snatch switch connector (connected) 42 Fuse—protects [+B5] terminal (F 3.15A 250V) 43 Fuse—protects [+B4] terminal (F 3.15A 250V) 44 Fuse—protects terminals [+N3] and [+A3] (F 3.15A 250V) 45 Fuse—protects terminals [+N2] and [+A2] (F 3.15A 250V) 46 Fuse—protects terminals [+N1] and [+A1] (F 3.15A 250V) 47 RAM chip 48 Auxiliary Communicator Jumper: // = Disabled (at default) oo = Enabled 49 Detachable Terminal board for Output device connections (Sirens, etc.)

C3 NC3 NA3

+N3 +A3 C2 NC2 NA2 +A2 +N2 C1 NC1 NA1 +N1 +A1 OC2 OC1 +B5 +B4 OC3 L2 +F +F ASB L3 +F L4 +F L5 +F1 L6 +F1 L7 +F1 L8 +F1 + C R + C R - L1 - LI LE STOP ALARM BL227 RED YEL GRN OPEN SNATCH EXT-CARD VOX BLK TEL VDS OVC PTC SERIAL PORT + C R – M AC/N FG +V GND B+ L B– GND +V AC/L F 3 . 1 5 A / 2 5 Ø V F 6 . 3 A / 2 5 Ø V 1 5 5 2 3 4 1 6 7 8 5 14 13 12 11 10 9 5 7a Figure 1 Kyo300 Control panel components (maximum configuration) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 22 23 24 21 20 19 18 17 25 26 27 28 29 30 31 32 33 34 43 44 45 35 BPI1 38 46 49 50 51 48 47 NC2 NA2 +N2 +A2 C2 C1 NC1 NA1 +N1 +A1 +B1 OC1 OC2 L4 L2 ASB L3 +F L6 +F L7 L8 + C R L1 - LI LE + STOP ALARM B020 RED YELGRN SNATCH EXT-CARD VOX BLK +F L5 +F 39 BPI2 42 + C R - MEM B020 F3.15A 250V OPEN AC/N FG +V GND B+ L B– GND +V AC/L F 3 . 1 5 A / 2 5 Ø V F 6 . 3 A / 2 5 Ø V 1 5 5 2 3 4 1 6 8 5 14 13 12 11 10 9 5 7a Figure 2 Kyo100 Control panel components (maximum configuration)

I Partitions Armed

a Alarms in Memory G Trouble and Zone in Test status M Message in Memory S Open Panel T Tamper Alarm b BPI Device Tamper f False Key/Card at Reader s BPI Device Missing t Teleservice enabled r Answering device enabled i Telephone line engaged KYO 300-KYO100 APPENDIX 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 30 31 32 29 28 27 26 25 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 BPI1 54 55 BPI2 58 59 60 61 62 65 66 67 64 63 NC3 NA3 +N3 +A3 C3 NC2 NA2 C2 +N2 +A2 C1 NC1 NA1 +N1 +A1 OC2 OC1 +B5 +B4 OC3 L2 +F +F ASB L3 +F L4 +F L5 +F1 L6 +F1 L7 +F1 L8 +F1 + C R + C R - L1 - LI LE STOP ALARM BL227 RED YEL GRN OPEN SNATCH EXT-CARD VOX BLK TEL VDS OVC PTC SERIAL PORT + C R – M 15 16 34 40 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 3837 36 35 39 41 42 43 44 45 46 47 49 50 51 48 Figure 3 Kyo300 Main board components AC/N FG +V GND B+ L B– GND +V AC/L F 3 . 1 5 A / 2 5 Ø V F 6 . 3 A / 2 5 Ø V 62 52 57 59 53 54 55 56 58 61 60 Figure 4 Switching Power Supply components No. DESCRIPTION 50 STOP ALARM Jumper: can be used to disable Outputs no. 1, 2 and 3 (terminals +N1, +A1, C1-NC1-NA1, +N2, +A2, C2-NC2-NA2, +N3, +A3, C3-NC3-NA3): oo = Output Enabled (at de- fault) // = Output Disabled 51 Tamper Microswitch connector (connected) 52 Eyelet terminals: to be con- nected to the backup battery 53 Stranded wires: connect the Switching Power Supply to the Main board (connected) 54 Fine Adjustment Trimmer 55 Auxiliary power terminals (13.8 V) 56 Mains terminals (230V / 50 Hz) 57 Switching Power Supply screw 58 Fuse — protects against over- load (F 3.15A 250V) 59 Rivet No. DESCRIPTION 60 Fuse — protects against Battery polarity inversion (F 6,3A 250V) 61 Mains LED 62 Output Voltage Control (con- nected) � MIA-D and Alison-DV Keypads 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 22 23 24 21 20 19 18 17 25 26 27 28 29 30 31 32 33 34 43 44 45 35 BPI1 38 46 49 50 51 48 47 C2 NC2 NA2 +N2 +A2 C1 NC1 NA1 +N1 +A1 +B1 OC1 OC2 L4 L2 ASB L3 +F L6 +F L7 L8 + C R L1 - LI LE + STOP ALARM B020 RED YELGRN SNATCH EXT-CARD VOX BLK +F L5 +F 39 BPI2 42 + C R - MEM B020 F3.15A 250V OPEN 16 22 21 23 17 25 30 31 29 24 26 27 28 34 35 42 37 39 47 49 15 50 51 38 33 32 41 40 20 Figure 5 Kyo100 Main board components

Inserimento A, B, C o D

Disinserimento Aree Reset Memorie Blocco Allarme� Cancella Telefonate Arming Partitions Arming Type A, B, C or D Disarming Partitions Reset Alarms Stop Alarms� Clear Calls Aree Inserite Sabotaggio Centrale Scomparsa Periferica Chiave Falsa Sabotaggio Periferica Sabotaggio Guasto Allarme Messaggio Teleassist. Abilitata Rispondit. Abilitato Telefonata in corso Armed Partitions Alarm Message Warning Panel Tamper Tamper Peripheral Tamper False Ke /Card y Missing Peri heral p Teleservice Enabled Answer Phone ON Call in progress ETIDFBL1ALS-S 0.0 290903 D10 o or 1 2 3 4 5 6 7 8 http:\\www.bentelsecurity.com n. Des. O A B C D o EE EDE ECE 63 69 76 66 67 80 64 70 65 71 75 77 78 79 75 74a 81 82 77 74 66 64a 73 72 71 82a 71 81 76 74 75 Figure 6 Alison-DV and Alison-S (Alison-S does not manage Voice, Microphone+Loudspeaker functions) 2abc 3def 1 5 jkl 6 mn o 4ghi 8tuv 9 7 pq rs 0 A # B C D E S C wx yz OFF ON 1 2 3 4 ON 5 + C R – +F L1 L2 SNATCH BPI 5V 5V 12V BPI LEV BL232 COM NO NC 2abc 3def 1 5 jkl 6 mn o 4 ghi 8 tuv 9 7 pq rs 0 A # B C D E S C wx yz OFF ON 1 3 5 7 2 4 6 8 63 69 71 66 67 66 65 64 70 71 72 80 71 75 74 76 79 7778 76 75 73 74 68 81 74 82 77 74 71 81 Figure 7 MIA-D keypad COM NO NC ETIDFBL1ALSL32P 0.0 030304 D10 1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 8 16 24 32 3 4 5 6 7 8 1 2 http:\\www.bentelsecurity.com n. Des. Stop allarmi Stop alarm Perdita datario Clock Wrong Aree Inserite Armed Part. Allarme Alarm Guasto Warning Pronto Ready Sabotaggio Tamper Sabot. Centrale Panel Tamper Zone Escluse Bypassed Zones Teleassistenza Teleservice Guasto Fusibile Fuse Trouble Mancanza Rete Mains Failure Guasto Batteria Battery Trouble Scomparsa Disp. Missing Device Guasto Linea Tel. Line Down Dati di Fabbrica Default Settings 2 abc A B C D ESC 1 3 def 5 jkl 4 ghi 6 mno 8 tuv 7 pqrs 9 wxyz 0 OFF # ON 2 abc A B C D ESC 1 3 def 5 jkl 4 ghi 6 mno 8 tuv 7 pqrs 9 wxyz 0 OFF # ON OUT 66 67 66 69 64 65 75 75 73 72 76 70 71 77 78 79 71 81 82 77 74 71 71 81 76 74 89 89a 89c 89b 89d Figure 8 Alison/32LP Keypad - The 32 LEDs on ALISON/32LP Keypads represent the 32 Partitions on KYO 300 and the 16 Partitions on KYO 100 (refer to the USER MANUAL for details).

63 Backlit LCD, 2 rows x 16 columns

64 Buzzer 64a Microphone (on ALISON-DV only) 65 Snatch Microswitch Connector 66 Frontplate screws (2) 67 Down flip 68 Microprocessor (solder side on ALISON-DV) 69 BPI Level Jumper: oo = 12 V (at default); // = 5 V 70 Cable entry 71 Board Supports (4) 72 Terminal board 73 BPI Level Jumper: 12V //o 5V = 12 V (at default) 12V o// 5V = 5 V 74 Screw locations (4 on MIA-D; 2 on ALISON -DV and Alison/32LP) for mounting to 10x10 outlet boxes or similar 74a Loudspeaker Input 75 Tamper Microswitches (2) 76 Screw locations (2) for mounting to mod. 503 outlet boxes or similar 77 Screw locations (2) for mounting on single gang, 2-gang or similar 78 PCB Clip 79 Snatch Microswitch (order code: ASNC) 80 Address DIP Switches 81 Board Supports (2) 82 Snatch bracket location 82a Loudspeaker (on ALISON-DV only) � Readers and Digital Keys No. DESCRIPTION 83 Backplate anchor screw locations (2) 84 Microprocessor 85 Connection wires: red = +; white = C; blue = R; black = – 86 Snatch microswitch connector 87 Snatch microswitch (accessory item) 88 Snatch microswitch location 89 Sensitive field 89a Address keypad LEDs 89b Address PROXI LEDs 89c PROXI reader LEDs 89d Address LEDs 90 Cover screw 91 Key slot 92 Command button 93 Snap catch 94 Cable entry 95 Tamper Microswitch KYO 300-KYO100 APPENDIX 13 C NO NC 1 2 3 4 ON 5 – 12V R C 5V + LB092-P BPI 5V BPI LEVEL SNATCH 1 2 3 4 ON 5 d) e) f) 83 a) b) c) 73 85 8687 88 84 80 95 69 94 83 93 80 73 72 89 90 91 92 69 Figure 9 Readers and Digital Key: PROXI Proximity Reader — internal view (a) external view (b); PROXI-CARD for Proximity Reader (c); ECLIPSE Contactless Reader with 5 DIP Switches , Magic Version — side view (d) front view (e); SAT Key for ECLIPSE and PROXI Readers (f)

Status of Reader Partitions

OFF = ALL the Reader Partitions are DISARMED; ON = AT LEAST ONE of the Reader Partitions is ARMED. Slow blinking = AT LEAST ONE of the Reader Partitions presents AT LEAST ONE Alarm or Tamper memory, and all Partitions are DISARMED. Fast blinking = AT LEAST ONE of the Reader Partitions presents AT LEAST ONE Alarm or Tamper memory, and AT LEAST ONE Partition is ARMED. amber A A Mode Arming: OFF = the status of the Keypad Partitions DOES NOT MATCH the A Mode Arming con- figuration; ON = the status of the Keypad Partitions MATCHES the A Mode Arming configuration. green B B Mode Arming: OFF = the status of the Keypad Partitions DOES NOT MATCH the B Mode Arming con- figuration; ON = the status of the Keypad Partitions MATCHES the B Mode Arming configuration. � These descriptions are not valid when a key is present at the Reader. � If ALL THREE LEDs blink, the system HAS NOT RECOGNIZED the Key/Card (false Key/Card). If ONE LED blinks, one or more of the Partition zones is already in Alarm status. � Input and Output Expanders No. DESCRIPTION 96 Snatch microswitch (solder side) 97 Microprocessor 98 Buzzer No. DESCRIPTION 99 Buzzer Mode Jumper: 1 ooo 3 = buzzer OFF (at default) 1 //o 3 = buzzer will activate when terminal [OC6] opens 1o// 3 = buzzer will activate when terminal [OC6] connects to negative 100 Tamper ands Snatch mode Jumper: oo = Microswitches enabled (at default) // = Microswitches disabled 101 Tamper microswitch 102 Terminal Board 103 Frontplate screw locations (4) 104 Expander (Input, Output, etc.) 105 Expander screws (2) 106 Cable entry 107 Screw locations (2) for mounting to 503 outlet box or similar 108 Cable duct entry 109 Surface mounting screw locations (2) 110 Snatch bracket 111 Plastic tooth (closes the Tamper microswitch) 14 5V 12V BPI 5V BL240 TAMP. DIS. BPI LEV. 1 2 3 4 ON 5 R C + L1 L3 L5 +F +F +F L2 L4 L6 1 2 3 4 ON +F +F +F +F R C OC3 OC1 + OC2 OC4 OC5 OC6 BPI 5V 3 1 TAMP. DIS. BPI LEV. 5V BL238 12V 72 a) b) 69 9697 73 72 80 69 73 102 80 101 100 102 96 101 98 99 100 97 Figure 10 M-IN/6 Input Expanders (a) and M-OUT/6 Output Expanders (b) 103 103 103 104 105 96 106 107 108 109 107 111 103 105 101 109 110 Figure 11 Module and Expander box

Mounting the Main Unit

Please read this section carefully to get an overall view of the steps involved in installing the KYO300-KYO100 Main Unit. The KYO300-KYO100 Main Unit should be located in a safe, dry place that is far from sources of interference. Once you have selected a suitable place, create a lay- out of all the system peripherals (Keypads, Readers, Detectors, etc.) and ensure that you will be able to con- nect the Main power, peripherals, and if necessary, the telephone line to the KYO300-KYO100 without diffi- culty. Allow at least 5 cm of free space around the Main Unit for air flow. ! The Main Unit must be at least 2 metres from GSM and radio relay systems. Work carefully through the following steps (see Figure on page 10). 1. Remove the screws 1 and frontplate. 2. Install add-on modules and boards (K3-VOX, K3-AUXCOM (KYO300 only), etc.), refer to the rel- evant paragraphs for instructions. 3. Drill the holes for the cabinet and Snatch bracket anchor screws (5 and 13 respectively). 4. Pull the connection wires through the wire entry 11 then attach the cabinet and Snatch bracket to the wall. � DO NOT over tighten the screws as this may dam- age the Snatch bracket. 5. Complete the connections — DO NOT connect the MAINS until all other wiring has been completed. 6. Connect the Mains Power (refer to “Connecting the Mains Power”). 7. Program the system (refer to the “PROGRAMMING” section and the “PROGRAMMING FROM KEYPAD” Guide for in- structions). � Connecting Keypads Keypads should be located in places where full control of the system is required: MIA-D, Alison-DV, Alison-S and Alison/32LP Keypads can be surface mounted on Mod. 503, 10x10 single gang and double gang outlet boxes or similar. � Keypads should be mounted at eye level for easy viewing. Work carefully through the following steps (see Figures on page 12) and/or respective manuals. 1. Remove the screws 66 and frontplate. If you are installing a MIA-D Keypad go to step 3. If you are installing an Alison-DV Keypad go to step 2. 2. Disconnect the Loudspeaker 82a from its Input 74a. 3. Push the PCB clip 78 upwards to release the PCB. 4. If you are surface mounting the Keypad: drill the holes for the backplate anchor screws 76, and if re- quired, also for the Snatch bracket screw 82. 5. If you are fitting a Snatch microswitch (Order Code: ASNC), push it firmly into its location (79 in Fig. ). Ensure that the Snatch microswitch lever is held firmly in position by the tooth on the Snatch bracket. A Keypads which are not fitted with Snatch microswitches, DO NOT COMPLY with IMQ-SECURITY SYSTEM Performance level II certification. 6. Pull the wires through the wire entry 70. 7. Using the anchor screws, secure the backplate and Snatch bracket to the wall. � Snatch microswitches cannot be fitted to outlet mounted Keypads. 8. Replace the PCB, and if required, connect the Snatch microswitch to the connector 65. If you are installing a MIA-D Keypad go to step 10. If you are installing an Alison-DV Keypad go to step 9. 9. Connect the Loudspeaker 82a to its Input 74a. KYO 300-KYO100 INSTALLING 15

10. Assign the Keypad Address, then set the BPI Level

and complete the connections on the terminal board (refer to “Connecting BPI Peripherals” for in- structions). 11. Reattach the frontplate. � Connecting Readers Readers can be located in places where limited control of the system is required (Arming, A and B Mode Arming, Disarming and Stop Alarm operations). This system supports Digital Key and Proximity Card Readers. Key Readers Key Readers can be flush mounted to most standard domestic light-switch/plug-socket outlet boxes (refer to “Accessory items” in the “INTRODUCTION” for the available models). � Digital Key Readers must be at least 10 cmapart. To install Key Readers, work carefully through the fol- lowing steps (see Figure on page 13). 1. Assign the Reader Address, then set the BPI Level and complete the connections on the terminal board (refer to “Connecting BPI Peripherals” for in- structions). 2. Fit the Reader in its placement (use the standard procedure for fitting domestic light-switches and plug sockets). A In order to comply with the Security System Regu- lations, outdoor Readers, and Readers located off the protected premises must be fitted with tamper protection devices (Fig. 12). Proximity Readers Proximity Readers can be surface mounted, or mounted to Mod. 503 outlet boxes or simi- lar. Proximity Readers are fitted with weather strips (Protection Class IP34), therefore, are suitable for out- door use. � Proximity Readers must be at least 50 cm apart. To install Proximity Readers, work carefully through the following steps (see Figure on page 13). 3. Remove the screw 90 (if fitted), then using a screw- driver or similar tool push down on the catch 93 to release the frontplate. 4. Drill the holes for the backplate and Snatch bracket anchor screws (83 and 88 respectively). 5. If you are fitting a Snatch microswitch (Order Code: ASNC-MINI), push it firmly into its location (87 in Fig. 9) then connect it to the connector 86. Ensure that the Snatch microswitch lever is held firmly in position by the tooth on the Snatch bracket. A Readers that are not fitted with Snatch microswitches, DO NOT COMPLY with IMQ-SECURITY SYSTEM Performance level II certification. 6. Secure the Reader and Snatch bracket to the wall. 7. Assign the Reader Address, set the BPI Level and complete the connections on the terminal board (refer to “Connecting BPI Peripherals” for instruc- tions). 8. Reattach the frontplate. � Connecting Input and Output Expanders Locate the Input and Output Expanders as near as pos- sible to the devices they will be connected to. The Expander box can be surface or flush mounted (see Figure on page 14). 1. Remove the knockout (106 or 108 as required). 2. – Surface mounting: drill the holes for the backplate and Snatch bracket anchor screws (109 and 110 respectively). – Flush mounting to Mod. 503 outlet box or similar: drill the hole for the Snatch bracket anchor screw 107. No other drilling is required for Flush mount- ing. 3. Pull the wires through the wire entry. 4. Secure the back box and Snatch bracket to the wall. 16 COM NO NC to the Tamper line Figure 12 Mounting Key Readers

� The Snatch bracket 110 must be fitted as shown in

the figure on page 14 (with the plastic tooth to the left of its location). 5. Replace the PCB inside the box. 6. Assign the Address, then set the BPI Level and complete the connections on the terminal board 72 (refer to “Connecting BPI Peripherals” for instruc- tions). 7. Remove the Jumper 100 — to enable the Tamper and Snatch microswitches. 8. Using the Jumper 99, set the Output Expander buzzer mode: 1 ooo 3 > buzzer disabled (at default); 1 //o 3 > buzzer will sound when terminal [OC6] opens; 1 o// 3 > buzzer will sound when terminal [OC6] closes to negative. 9. Replace the frontplate. � Ensure that the plastic tooth 111 on the frontplate, closes the Tamper microswitch 101 properly. The Terminals This section describes the Main Unit and BPI device ter- minals. The layout of Terminal Description table is as follows: � the Ter. column shows the terminal identifier; � the DESCRIPTION column provides a brief descrip- tion of each terminal; � the v(V) column shows the terminal voltage (the hy- phen “–” indicates that the voltage cannot be speci- fied for the terminal in question); � the I(A) column shows the maximum current (in Am- peres) that can circulate on the terminal (the hyphen “–” indicates that the current cannot be specified for the terminal in question); � the numbers in brackets refer to the following notes. (1) The total current draw of Main Unit terminals [+A3], [+N3], [+A2], [+N2], [+A1], [+N1], [+B4], [+B5], [+F], [+F1], [+] and [RED] must not exceed 3.5 A for KYO 300, or 1.7 A for KYO 100. (2) The current draw of BPI device [+] terminals is: � Keypad = 0.05 A for MIA-D, and 0.04 for Alison-DV and Alison-S, 0.07A for Alison/32LP � Reader = 0.03 A � Input Expander = 0.02 A � Output Expander = 0.02 A � These values refer to the current draw of the BPI devices with no loads. (3) The total current draw of the Input/Output Expander [+F] terminals should not exceed 0.4 A. � Main Unit Ter. DESCRIPTION v(V) I(A) NA3 NC3 C3 Programmable Output no. 3 (changeover switch contacts) – 3 +A3 Programmable Output no.3 (posi- tive), protected by fuse 44 13.8 3(1) +N3 Programmable Output no. 3 (in- trinsic security), protected by fuse 44 13.8 3(1) NA2 NC2 C2 Programmable Output no. 2 (changeover switch contacts) – 3 +A2 Programmable Output no. 2 (posi- tive), protected by fuse 45 13.8 3(1) +N2 Programmable Output no. 2 (in- trinsic security), protected by fuse 45 13.8 3(1) NA1 NC1 C1 Programmable Output no. 1 (changeover switch contacts) – 3 +A1 Programmable Output no. 1 (posi- tive), protected by fuse 46 13.8 3(1) +N1 Programmable Output no. 1 (in- trinsic security), protected by fuse 46 13.8 3(1) +B4 Positive power supply to peripher- als, protected by fuse 43 (will be powered by the battery during Mains failure) 13.8 3(1) +B5 Positive power supply to peripher- als, protected by fuse 42 (will be powered by the battery during Mains failure) 3(1) M Negative 0 – OC1 Programmable Output no. 4 (Open-Collector) 0 1 OC2 Programmable Output no. 5 (Open-Collector) 0 1 OC3 Programmable Output no. 6 (Open-Collector) 0 1 ASB 10 K�Balance Tamper Line – – L1 : L8 Programmable Input Line – – +F Power supply to detectors (posi- tive), protected by fuse 37 (will be powered by the battery during Mains failure) 13.8 3(1) +F1 Power supply to detectors (posi- tive), protected by fuse 36 (will be powered by the battery during Mains failure) 13.8 3(1) BPI1 1° branch of the BPI bus for the BPI peripherals: + = positive protected by fuse 35 C = Command R = Response – = Negative 13.8 3(1) KYO 300-KYO100 INSTALLING 17

BPI2 2nd branch of the BPI bus for the

BPI peripherals: + = positive protected by fuse 35 C = Command R = Response – = Negative 13.8 3(1) RED BLK YEL GRN KEY BUS: positive protected by fuse 29 negative clock data – 0.5 (1) - Earth Terminal 0 – LE External telephone line terminals – – LI Line-sharing devices terminals (for Answerphone, telephone, fax, mo- dem, etc.) – – NOTE: Only KYO 300 has terminals identified by the numbers 3 or 4 (e.g.. A3....) � BPI Peripherals The terminals shown in the following table are common to all BPI peripherals. Ter. DESCRIPTION v(V) I(A) + Power supply: positive 13.8 (2) C Command – – R Response – – – Power supply: negative 0 – Keypad Keypads have the common BPI bus connec- tion terminals, and the following terminals. Ter. DESCRIPTION v(V) I(A) +F Power supply to Detectors (posi- tive), protected by resettable fuse 13.8 0.4 L1 Programmable Input Line – – L2 Programmable Input Line (MIA-D only) Ter. DESCRIPTION v(V) I(A) MIC SP+ SP– Terminals for the connection of the K3-VOX Voice Board (Alison-DV only) M Power supply to Detectors (nega- tive) 0 – OUT Programmable Open-collector Output (Alison/32LP only) 0 0,15 Input Expanders Input Expanders have the common BPI bus connection terminals, and the following termi- nals. Ter. DESCRIPTION v(V) I(A) +F Power supply to Detectors (posi- tive), protected by resettable fuse 13.8 (3) L1 : L6 Programmable Input Lines – – M Detector Power supply (negative) 0 – Output Expanders Output Expanders have the com- mon BPI bus connection terminals, and the following terminals. Ter. DESCRIPTION v(V) I(A) M Power supply (negative) to the pe- ripherals connected to the Open-Collector Outputs 0 – +F Power supply (positive) to the pe- ripherals connected to the Open-Collector Output, protected by resettable fuse 13,8 (3) OC1 : OC6 Programmable Open-Collector Output 0 0.15 18 + C R – BPI device C R + – BPI device R C + – Panel Power station R C + R C + BPI IN BPI OUT BPI device R C + – Figure 13 Connection of 4 BPI Devices

The section describes how to wire the Main Unit, BPI

bus peripherals and various security devices. Each wiring diagram refers to a specific type of device (BPI bus devices, Detectors and Signalling devices). � Use shielded cable for all connections, with one end connected to negative and the other floating. ! The end of the stranded conductor must not be soft soldered in places where it is subject to contact pressure. ! The Mains wiring must comply with the rules for double or reinforced insulation. � Use an adhesive cable grip to secure the wires to the terminal boards. The wiring diagrams show some of the many tailored solutions this system provides. About the Wiring Diagrams The locations of the ter- minals in the wiring diagrams may be different to those on the board. � the Zone terminals may belong to the Control panel, Keypads or Output Expanders; � the Open-Collector Output terminals may belong to the Control panel or Output Expanders; � the Input zone and the Open-Collector Output termi- nals (in the wiring diagrams) can be found on the Main Unit or Expanders; � only the terminals required for the connection are shown in the wiring diagrams. Connecting BPI Bus Devices The BPI bus supports the following devices: � up to 32 Keypads (16 for KYO 100) � up to 32 Readers (16 for KYO 100) � up to 32 Input Expanders (16 for KYO 100) � up to 16 Output Expanders � up to 8 Power stations � up to 16 LED Keypads Electrical Connections The BPI bus devices must be connected in parallel to terminals [+], [C], [R], [–] on the Main Unit, as shown in Fig. 13. The Power Station has two groups of terminals for the BPI bus connection: the BPI-IN group — for the Power Station; and the BPI-OUT group — for the BPI devices connected downstream of the Power Station. The two groups of terminals are electrically isolated, therefore, all the cables and devices connected down- stream of the Power Station will not load the Control panel BPI bus. Refer to the Power Station Instructions leaflet for further details. � Only one Power Station can be connected to each shunt of the Control panel BPI bus (see Fig. 14). Dual Branch Bus The Control panel BPI bus has two independent branches: Branch 1 (BPI1) — terminals no. 51, 52, 53 and 54; Branch 2 (BPI2) — terminals no. 55, 56, 57 and 58. Each Branch is protected by its own fuse, therefore, short-circuit on one branch will not impair the operating capacity of the other. � The Outdoor Control panel BPI bus peripherals should be connected to one Branch of the BPI bus, and theIndoor peripherals to the other. In this way, tamper on one branch will not impair the operating capacity of the other. KYO 300-KYO100 INSTALLING 19 Yes Yes NO BPI device Panel Power station BPI device BPI device BPI device BPI device Power station BPI device BPI device BPI device BPI device Power station BPI device Power station Figure 14 Connecting a Power Station

Assigning Addresses You must assign an Address

to each of the BPI bus devices. The assigned Address will allow the Control panel to distinguish one device from another. The Peripheral devices are divided into types: Keypads, Readers, Input Expanders, Output Ex- panders and Power Stations. Devices of the same type (e.g. two Readers) must have different Addresses. Devices of different types (e.g. a Keypad and a Reader) are intrinsically different, therefore, may have the same Address. The BPI bus peripheral Addresses can be assigned in any order, using the DIP switches 80 (refer to Table 1). � Output Expanders have 4 DIP switches, and can be assigned to Addresses no. 1 through no. 16 ONLY. For the relevant Address Combinations refer to the numbers in brackets in Table 1. � Refer to the Power Station Instructions leaflet, and the Alison/32LP keypad Instructions leaflet, for the Address setup. Power Stations can be assigned to Addresses no. 1 through no. 8 ONLY. The posi- tion of DIP switch no. 1 in uninfluential. Setting the BPI Level The BPI Level determines the maximum voltage the BPI bus can carry. Some BPI de- vices have 5V and 12V options. � This Control panel operates at 12V, therefore, all the peripheral devices must be set at 12 V. Using the Jumpers 69 and 70, set the BPI Level as fol- lows: BPI Level Jumper 69 Jumper 70 5 V // 5 V 12 V o// 5 V 12 V oo 5 V 12 V //o 5 V � Refer to the Power station Instructions leaflet for the BPI Level setup. ALISON/32LP ASSIGNING ADDRESSES To assign the addresses to the ALISON/32LP Keypad and Prox- imity Reader work carefully through the following step: 1.Remove the frontplate in order to generate a Tamper status. 2.Connect the Keypad to the Control panel BPI BUS (terminals +, C, R, -). 3.Remove the jumper 73: � after 5 seconds the keypad will emit an audible signal and the 4 LEDs on the left (89a in Figure 8) will turn ON; � the four pairs (up/down) of LEDs (89d in Figure 8) will simu- late 4 DIP switches; � one of the first pair of LEDs will blink to indicate ac- cess to the Addressing phase. 4.Assign an Address to the Keypad. � Use A or B to select the LED/DIP switch. � Use C or D respectively, to turn the LED ON or OFF as required, in accordance with the following logic: Upper RED LED ON = DIP switch ON Lower LED ON = DIP switch OFF � �� ��� ���� �� ������ ��� ������� ��� �������� ����� e. � NOTE: You can assign the same Address to the Keypad and Proximity Reader as these devices are intrinsically different. 5.Press E to confirm the selected Address: � after several seconds the Keypad will emit an audi- ble signal, and the 4 LEDs on the right (see 89b in Figure 8) will turn ON to indicate access to the Ad- dressing phase of the built-in Proximity Reader. � If you DO NOT wish to use the Proximity Reader, press o. The ALISON/32LP will go back automati- cally to the Keypad Addressing phase, at which point, go to step 8. in this section. � If you wish to use the Proximity Reader, go to step6. 6.Following the instructions in step 4., assign an Ad- dress to the Reader. � If you wish to cancel the setting and restart, press e. � NOTE: If you press e at this point, the ALISON/32LP will cancel the setting and step back to the Keypad Addressing phase. 7. Once you have assigned the Keypad and Reader Addresses, press E. 20 No. ADDRESS COMBINATIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 (0) off off off off off off off off off off off off off off off off ONONONONONONONONONONONONONONONON 2 (1) off off off off off off off off ONONONONONONONONoff off off off off off off off ONONONONONONONON 3 (2) off off off off ONONONON off off off off ONONONONoff off off off ONONONON off off off off ONONONON 4 (3) off off ONONoff off ONON off off ONON off off ONONoff off ONONoff off ONON off off ONONoff off ONON 5 (4) off ONoff ONoff ONoff ON off ON off ON off ON off ONoff ONoff ONoff ON off ON off ON off ONoff ONoff ON Table 1 Expander Moduleand Power Station Addresses. The No. column shows the DIP switch number (1 through 5 for devices with 5 DIP switches, and 1 through 4 in brackets for devices with 4 DIP switches).

8. Reinsert the Jumper 73 immediately, in accordance

with the selected BPI Level (refer to “Setting up the BPI Level”), then replace the frontplate. � BPI bus Wiring Limitations Due to Voltage drops and stray capacitance caused by the Control panel BPI bus connections, the following wiring limitations must be respected: � the maximum wire length between the Control panel and the BPI peripheral must not exceed 500 metres; � the overall wire length of each branch of the Control panel BPI bus must not exceed 1000 metres. In order to allow the BPI peripherals to operate properly, 11.5V or more must be present across terminals [+] and [–]. If a lower voltage is present, it can be boosted by: � increasing the wire section that supplies the Control panel BPI device (the wires that connect [+] and [–] of the Control panel to terminals [+] and [–] of the BPI device); � connecting some of the BPI peripherals downstream of a Power Station (these devices will be powered by the Power Station, therefore, will not load the Control panel BPI bus); � using a Power Station to provide the voltage for the BPI peripheral load. � The cable length downstream of a Power station should not to be included the overall wire length for each branch of the Control panel BPI bus. Due to Voltage drops and stray capacitance caused by the Power Station BPI bus connections, the following wiring limitations must be respected: � the maximum wire length between the Power Sta- tion (BPIOUT terminals) and the BPI peripheral must not exceed 500 metres; � the overall wire length between the Power Station (BPIOUT terminals) and the BPI bus peripherals must not exceed 1000 metres. Connecting Detectors The KYO300 system has 8 zones, expandable to 3121 zones (to 168 for KYO 100) by means of M-IN/6, MIA-D, Alison-DV and/or Alison/32LP Keypads and the VectorRX: 8 Zones on the Main Unit 64 Zones 16 Zones on32MIA-DKeypads(2ZonesperKeypad) on 16 Alison/32LP Keypads 192 Zones on 32 Input Expanders (6 Zones per Ex- pander) 32 Zones 312 Zones on the Receiver (168 for KYO 100) Total The Receiver zones (wireless zones) are for the wireless detectors. The Main Unit, Keypad and Input Expander zones (hardwired zones) are for the hardwired detectors. This section describes the connection of hardwired de- tectors. The terminals of the hardwired zones are marked [L1], [L2], etc. The following terminals can be used for the power sup- ply to the detectors: either [+F] and [M] (negative) or [+F1] and [M] (nega- tive), for each zone on the Main Unit. 13.8 V positive is present on Main Unit [+F] and [+F1] ter- minals — protected by fuses 37 and 36(F 3.15A 250V). [+F] and [M] (negative) for each pair of zones on Key- pads and Input Expanders. 13.8 V positive is present on Keypad and Input Expander [+F] terminals — protected by resettable fuse (0.4 A). Each zone can support several detectors. However, if more than one detector is connected, the Control panel will be unable to identify the detector in the event of an Alarm. KYO 300-KYO100 INSTALLING 21 BALANCE TYPES R NO NC 10 K 10 K ALARM DOUBLE GLASS BREAK � STANDBY ALARM ALARM ALARM TAMPER TAMPER 10 K ALARM STANDBY STANDBY STANDBY ALARM STANDBY 5 K ALARM STANDBY SHORTED ALARM STANDBY ALARM 0 ALARM STANDBY SHORTED ALARM SHORTED SHORTED Table 2 Balance Types: the R column shows the resistance across the Zone terminal and the Negative during the corresponding status (� indicates that the terminal is open; 0 indicates that the terminal is shorted to negative) 1 If you install MIA-D Keypads (2 on-board zones), the system can be expanded to 312 zones. If you install Alison-DV Keypads (1 on-board zone), the system can be expanded to 280 zones and 16 LED Keypads (1 zone per Keypad).

This system can detect Alarm, Tamper and Short-circuit

on hardwired zones: � Zone Alarm will be signalled by an Alarm on zone no. event; � Zone Tamper will be signalled by a Tamper on zone no. event; � Short-circuit will be signalled by a Tamper on zone no. event. The Zone status depends on several parameters (refer to “Hardwired Zones” in the “PROGRAMMING FROM PC” section). This section refers to the Balance type. If only this parameter is considered, the zone status will depend on the resistance between its terminal and neg- ative, as shown in Table 2. The following paragraphs describe the connections of various types of detectors. � The 10 K� resistors are included in the Resistor pack. The 10 K� resistors have brown, black, orange and gold bands. The last band (gold) indicates the toler- ance, and therefore, may be a different colour. � Connecting Motion Detectors Most Motion detectors have Normally-Closed Contacts (NC in the wiring diagram), and Normally-Closed Tam- per Contacts (AS in the wiring diagram). The zone balance can be programmed as: – Normally Closed – Normally Open – 10 K – 10 K Alarm – Double – Glass Break The connection type depends on the selected balance. In Figures 15, 16 and 17 the: � [+] and [–] terminals represent the positive and nega- tive terminals; � [NC] terminals are the Normally Closed Alarm Con- tacts of the detector; � [AS] terminals are the Normally Closed Tamper Con- tacts of the detector. Normally Closed The wiring diagram in Fig. 15 illus- trates the connection of a detector to a zone with Normally Closed balance. 22 detector N. C. A. L1 +F S. Panel tamper line Input exp. Keypad Figure 15 Connecting a Detector to a zone with Normally Closed balance 10 K� detector N. C. A. L1 +F S. tamper line Panel Input exp. Keypad Figure 16 Connecting a Detector to a zone with 10 K or 10 K Alarm only balance

Normally Closed balance will allow the Control panel to

detect Alarm status on the zone: – the zone will hold Standby status whilst connected to negative; – the zone will trigger Alarm under all other conditions. To provide Tamper detection: connect the Tamper con- tact of the detector to the Control panel Tamper Line, or to a 24h zone (refer to “Connecting Tamper Contacts”). 10 K The wiring diagram in Fig. 16 illustrates the con- nection of a detector to a zone with 10 K, or 10 K Alarm Only balance. ! The 10 K� resistor must be connected to the last detector of the zone. 10 K balance will allow the Control panel to detect Alarm and Short-circuit on the zone: – the zone will hold Standby status when connected to negative via a10 K� resistor; – the zone will trigger short-circuit when connected to negative; – the zone will trigger Alarm under all other conditions. To provide Tamper detection: connect the Tamper con- tact of the detector to the Control panel Tamper Line, or to a 24h zone (refer to “Connecting Tamper Contacts”). 10 K Alarm Only The wiring diagram in Fig. 16 illus- trates the connection of a detector to a zone with 10 K, or 10 K Alarm Only balance. ! The 10 K� resistor must be connected to the last detector of the zone. 10 K Alarm Only balance will allow the Control panel to detect Alarm status on the zone: – the zone will hold Standby status when connected to negative via a10 K�; – the zone will trigger Alarm under all other conditions. Double The wiring diagram in Fig. 17 illustrates the connection of a detector to a zone with Double balance. This type of zone will allow the Control panel to detect zone Alarm, Tamper and Short-circuit: – the zone will hold Standby status whilst connected to negative via a 5 K� resistor (i.e. using two 10 K� resis- tors connected in parallel); – the zone will trigger short-circuit when connected to KYO 300-KYO100 INSTALLING 23 10 K� 10 K� detector N. C. A. L1 +F S. Panel Input exp. Keypad Figure 17 Connecting a Detector to a zone with Double balance L1 +F glass break detector 10 K� glass break detector glass break detector Panel Input exp. Keypad Figure 18 Connecting 3 Glass Break Detectors to a zone with Glass Break balance

– the zone will trigger Tamper when open;

– the zone will trigger Alarm under all other conditions. � Zones with Double balance can detect and signal Alarm and Tamper by means of just two wires. To provide Tamper detection on zones with Normally Closed or 10 K balance: either connect the detector tamper contact to the Con- trol panel Tamper Line — this type of connection does not provide identification of the tampered detector; or connect the detector tamper contact to a 24h zone — this type of connection requires two zones — one for Alarm detection, and the other for Tamper detection (re- fer to “Connecting Tamper Contacts”). � Glass Break Detectors Fig. 18 illustrates the connection of 3 Glass Break de- tectors to a zone with Glass Break balance. ! Glass Break zones accept up to 20 detectors. The continuous lines in the wiring diagram represent the soft-soldered conductors of the detector, and the broken lines represent the copper wires. Connect the Glass Break detectors in parallel between the zone and negative, and a 10 k� resistor in parallel to the last detector. This balance type will allow the Control panel to detect Alarm, Tamper and Short-circuit on the zone: – the zone will hold Standby status whilst connected to negative via a 10 K� resistor; – the zone will trigger short-circuit when connected to negative; – the zone will trigger Tamper when open; – the zone will trigger Alarm under all other conditions. � Connecting Fire Detectors The KYO300 accepts Fire detectors with Alarm -Repeat Outputs that operate at 12 V (e.g. BENTEL SECURITY RT101, RT102 and RF501t). See Fig. 19 for the wiring diagram. Connect the Alarm-Repeat Outputs of the Fire detec- tors in parallel to a FIREzone (Normally Open — 24h). Connect the positive supply terminal of the detectors to terminals [+F]. Connect the negative supply terminal of the Fire detec- tors to an Open-Collector Output programmed as: – Monostable – Normally Closed – 20 seconds ON Time Assign the Output to an event that will reset the Fire de- tectors (e.g. Reset Panel or Reset Partition). In this way, when the programmed event occurs, the negative power supply to the fire detectors will be inter- rupted for 20 seconds thus resetting the Fire detectors. Connecting Alarm Signalling Devices Alarm Signalling Devices, such as: Self-Powered Si- rens, Indoor Sirens, Telephones Diallers, etc., can be classified as follows: � Intrinsic Security Devices (e.g. Self-Powered Si- rens) activated by voltage failure on the relevant ter- minal; � Positive Alarm Line devices(e.g. Indoor Sirens) ac- tivated by positive (12 V) on the relevant terminal. 24 fire detector fire detector fire detector +A +A +A R R R +B +F OC1 L2 +B +B – – – +F L3 +F L4 Panel Input exp. Panel Output exp. Keypad Figure 19 Connecting 3 Fire Detectors to a Zone with Normally Open balance

� Negative Alarm Line devices activated by negative

positive on the relevant terminal. � Balance Alarm Line devices activated by imped- ance unbalance on the relevant terminal. This Control panel has 6 Outputs — expandable to 118 by means M-OUT/6 Outputs Expanders: 6 Outputs on the Main Unit 96 Outputs 16 Outputs 118Outputs on 16 Output Expanders (6 Outputs per Expander) On 16 LED Keypads (1 Output per Key- pad) (116 for KYO 100) Total The three Outputs on the Main Unit (no. 1, 2, and 3) comprise terminals: � +N1, +A1, C1-NC1-NA1 � +N2, +A2, C2-NC2-NA2 � +N3, +A3, C3-NC3-NA3 (KYO 300 only) All other Outputs comprise terminals OC1, OC2, etc. The Standby status of the Outputs can be programmed as follows: � [+N] terminals can be connected to positive (13.8 V) or can be open, and therefore can be used to activate Intrinsic Security Devices; � [+A] terminals can be open or connected to positive (13.8 V), and therefore can be used to activatePosi- tive Alarm Line devices; � [C] terminals can be connected to their respective terminals [NC] or [NA], and therefore, can be used to activate all types of signalling devices; � [OC] terminals can be open or connected to nega- tive, and therefore, can be used to activate Negative Alarm Line devices � The OC terminals on the Main Unit can switch a maximum of 1 A whereas, the OC terminals on the Output Expanders can switch a maximum of 0.15 A. An Omnia/4R Relay board is required to switch higher values. The activation/restoral of Outputs depends on various parameters (refer to “Outputs” under “PROGRAMMING FROM PC”). The wiring diagram in Fig. 20 illustrates connection of a Self-powered Siren and an Indoor Siren to Outputs no. 1 and no. 2 on the Main Unit: � Outputs no. 1 and no. 2 on the Main Unit are pro- grammed as Normally Closed; � [+N] is the positive power and Input of the Self-pow- ered Siren. The Siren will activate when positive (13.8 V) fails on the [+N] terminal; � [+B] is the positive power and Input of the Indoor Si- ren. The Siren will activate when positive (13.8 V) is applied to the [+N] terminal; � [M] and [GND] are the negative power terminals of the Self-powered Siren and Indoor Siren; � [A.S.] and [AS1-AS2] are the Normally Closed Tam- per contacts of the Self-powered Siren and Indoor Si- ren. To provide Tamper detection: connect the Signalling device Tamper contact to the Control panel Tamper Line or to a 24h zone (refer to “Connecting Tamper Contacts”). KYO 300-KYO100 INSTALLING 25 +A2+N2 self-powere siren Panel A. S. AS1 AS2 GND +B +A1+N1 indoor siren tamper line +N Figure 20 Connecting a Self-powered Siren and an Indoor Siren to Main Unit Outputs no. 1 and no. 2

� Supervised Outputs (KYO 300 only)

Outputs no. 1, 2 and 3 can be set up as Supervised Out- puts. This type of output must be programmed as Normally Closed (refer to “Attributes” under “Outputs” in the “PROGRAMMING” section). The Control panel can detect short-circuit and Connection interrupt to termi- nals +A of Outputs with this attribute. The wiring dia- gram in Fig. 21 illustrates the connection of an Indoor Siren to a Supervised Output using a 2.2 K� across ter- minals +A and negative. The two 2.2 K� resistors (included in the package) have 3 red bands and a gold band. The last band (gold) indicates the tolerance, therefore, it may be a different colour. � The 2.2 K� resistor must be connected to the last device on the Output, otherwise it will have no ef- fect. Short-circuit and Connection interrupt to terminal +A of Supervised Outputs, will be signalled by: � Tamper on supervised output — relative to the Output; � flashing on the a indicator on the Keypads. � The a indicator will flash until the cause of Alarm is cleared (memory). The a indicator will stop flashing when the Control panel resets. Connecting Tamper Terminals The Tamper contacts of the security system devices can be connected to the 19 K Balance 24h Tamper Line. The Tamper Line terminal is marked ASB: � The Tamper Line will hold Standby status when con- nected to negative via a 10 K� resistor; � The Tamper Line will trigger an Alarm under all other conditions. Alarm on the Tamper Line will be signalled by: � a Tamper on Main unit event; � flashing on the T indicator on Keypads. � The Tindicator will flash until the cause of Alarm is cleared (memory). The T indicator will stop flash- ing when the Control panel resets. The wiring diagram in Fig. 22 illustrates the connection of 3 Tamper contacts to the Main Unit Tamper Line: � connect the device tamper contacts in series; � connect a 10 K� resistor in series to the last Tamper contact; � connect one end of the series to the [ASB] terminal and the other to the [M] terminal. ! The 10 K� resistor must be connected to the last device on the Output. If the Tamper line is not used, connect a 10 K� resistor across terminals [ASB] and [M]. � If several contacts are connected to the Tamper Line, the tampered device will be unidentifiable. To identify tampered devices: � select Double Balance for Motion detector connec- tions (refer to “Double Balance” under “Connecting Motion Detectors”); � connect each Tamper contact to a 24h zone with 10 K or 10 K ALARM ONLY balance (see Fig. 23). 26 +A3+N3 Panel AS1 AS2 GND +B indoor siren tamper line 2,2 K� Figure 21 Connecting an Indoor Siren to a Controlled Output on the Main Unit

Tamper contact zones can be programmed with

Normally Closed balance, in which case, the 10 K� resistors must not be connected. KYO 300-KYO100 INSTALLING 27 A. A. A. S. ASB S. S. Panel 10 K� Figure 22 Connecting 3 Tamper contacts to the Main Unit Tamper Line — the [A.S.] terminals represent the Normally Closed Tamper contacts of the device A. S. 10 K� L4 +F Panel Input exp. L5 +F L6 +F 10 K� 10 K� A. S. A. S. Keypad Figure 23 Connecting 3 Tamper contacts to three 24h Zones with 10 K or 10 K ALARM ONLY balance — the [A.S.] terminals represent the Normally Closed Tamper Contacts of the device

Connecting the Telephone Line

In order to allow use of the Dialler, Digital communicator and Teleservice facilities, the telephone line must be connected to terminals [LE], as shown in Fig. 24. This Control panel can detect Telephone line trouble (Line down), which will be signalled when the voltage on the [LE] terminals drops below 3 V for over 45 seconds. Telephone line trouble will be signalled by: � the Line-down event; � ON status of the G indicator on Keypads; � flashing on the i indicator on Keypads. The Control panel will signal restoral when the voltage on the LE] terminals returns to 3 V for over 15 seconds. � If the telephone line IS NOT CONNECTED to the Panel, the Telephone line check option must be DISABLED. If it is not Disabled, the Control panel will signal Line-down status persistently (refer to “Telephone” in the “PROGRAMMING” section). Connect Line-sharing devices (Fax, Answerphone, etc.) to the [LI] terminals. This will allow the Control panel to take priority ONLY in the event of an alarm. Connect the [-] terminal to the Mains Earth — this will protect the PCB against surges from the Telephone line. ! Ensure that the Mains Earth is fully intact and operating properly before connecting the Tele- phone line. Connecting a Power Supply In order to comply with the Safety regulations in force, the Mains must be equipped with a bipolar isolating de- vice for protection against over voltage and short-circuit to Earth (e.g. automatic isolating switch). The KYO300 is powered from the Mains (230V/50 Hz) through a Switching power supply, located inside the cabinet. The cabinet can also house a backup battery (not included) for power backup during Mains failure. Programmed data will be protected at all times by the RAM battery. Mains failure will be signalled by the: � OFF status of indicator 28 on the Main board; � ON status of the G indicator on Keypads; � Warning Mains failure event. � The Warning Mains failure event will be signalled after the programmed delay (refer to “Filter Times” in the “PROGRAMMING FROM PC” section). The Control panel will monitor the battery at all times, (refer to Static Test and Dynamic Test). Static Test The Static Test monitors the battery charge during Mains failure. Low battery status (below 11.4 V) will be signalled by the: � Low battery event; � ON status of the G indicator on Keypads. If this occurs, the Mains power must be restored before the battery empties, otherwise, the system will shut- down. Low battery restoral (over 12.3 V) will be signalled by: � the end of the Warning low battery event; � OFF status of the G indicator on Keypad. Dynamic Test The Dynamic Test monitors the oper- ating capacity of the battery. Failed Test (battery does not meet the Test requirements) will be signalled by the: � Warning power trouble event; � ON status of the G indicator on Keypads. If this occurs, the backup battery must be replaced im- mediately, otherwise, the system will be unable to func- tion in the event of Mains failure (black-out). Battery trouble restoral will be signalled by the: 28 telephone plug a LE LI Mains earth This connection is necessary! Panel b c Figure 24 Connecting the Telephone Line to the Main Unit

� end of the Warning power trouble event;

� Off status of the G indicator on Keypads. � Connecting the Mains Work carefully through the following steps (refer to “Parts Identification”). 1. Locate the backup battery in its housing 10. 2. Using the wires 52, connect the backup battery: Red wire to Positive terminal; Black wire to Negative terminal. � In the event of battery polarity inversion, replace the fuse 60 (F 6.3A 250V). 3. Connect the Earth wire to the [Q] terminal on the ter- minal board 56. 4. Connect the Neutral wire to terminal [N], and the Line wire to terminal [L] on the terminal board 56. � The Main Unit Tamper Microswitch is enabled by the initial closure of the Control panel. Therefore, it cannot trigger a Tamper on Panel event on first power up. Likewise, if the Panel is opened during a programming session (via Keypad or computer), the Tamper Microswitch will be inhibited thus unable to trigger a Tamper on Panel event until the Pro- gramming session ends, and the Panel is closed again. � Auto-configuration On first power up, the Control panel will carry out an Auto-configuration. During this phase the Control panel will enroll the BPI Bus peripherals. The auto-configura- tion can be changed during the programming session. The Auto-configuration phase takes approximately 15 seconds. Termination of this phase will be indicated on the LCD Keypads as follows: 00:00 01/01/2000 DDDDDDDD Connect the jumper 21 (M) to enable the RAM battery. � RAM Battery (see page 11) The RAM must be powered by a 3 V GLD CR2032 Lith- ium battery or similar. This battery will allow the system to store the programmed parameters for 71 days of total black-out (Mains and Battery). The RAM battery will last approximately 2 years, after which time it must be replaced. Empty RAM battery will be signalled by the: � ON status of the G indicator; � Warning Generic event. � The ON status of the G indicator, and the Warning Generic event signal many types of Trouble events. The Trouble details can be found on the LCD Keypads (in View Mode). If the trouble is re- lated to the RAM battery the Warn. Lithium batt message will be shown. To Install a Fresh RAM Battery: 1. Ensure that the Control panel is powered by the Mains or backup battery, otherwise, all the programmed param- eters will be cleared when the21 (M) Jumper is removed. 2. Remove the jumper 21 (M). 1. Using a flat screwdriver, remove the battery from its location 23. ! DO NOT TOUCH the PCB with the screwdriver or Battery, as this may provoke short-circuits. 2. Insert the fresh Battery in the battery location 23 (positive to the top). KYO 300-KYO100 INSTALLING 29 L Panel N Automatic Isolating Switch + – Backup Battery Line Neutral Earth 230 V 50 Hz Figure 25 Connecting the Mains power

! ONLY use 3 V GLD CR2032Lithium batteries or

similar, as there is a serious risk of EXPLOSION if other types are used. When dis- posing of used batteries follow the instructions and precautions printed on the battery. 3. Reinsert the Jumper 21 (M). � Thermal Probe This Control panel has an on-board connector 31 for a KST thermal probe (accessory item). The probe will op- timize the backup battery charge process, by regulating the charge voltage in accordance with the temperature of the backup battery. Work carefully through the following instructions (refer to the figure on page 10): 1. Connect the probe 9 to the connector 31 (PTC) on the PCB. 2. Measure the Probe temperature. 3. Using the graph in Figure 26 and/or Table 3, find the value (in accordance with the battery tempera- ture) that the Switching Power supply output volt- age will be based on. 4. Using the trimmer 54, adjust the voltage on the ter- minal board 55 to the required value. 5. Attach the probe to the backup battery, in such a way as to obtain optimum heat transfer. 30 -10 -5 0 5 10 15 20 25 30 35 40 45 50 13,0 13,5 14,0 14,5 VOLTAGE (V) TEMPERATURE (°C) a) 13,7 22 Figure 26 Switching Power Supply Output Voltage graph. To find the Output Voltage using the graph: — indicate the Probe temperature on the TEMPERATURE (°C) axis; draw a line from the temperature value point up to the curve a); draw a line from the intersection point across to the VOLTAGE (V) axis; adjust the Output Voltage of the Switching Power Supply to the resultant value. For example, if the Probe temperature is 22 °C, the Output Voltage of the Switching Power Supply must be set at 13.7 V. TEMPERATURE (°C) -10 -5 0 5 10 15 20 25 30 35 40 45 50 VOLTAGE (V) 14.5 14.4 14,3 14,1 14,0 13,9 13,7 13,6 13,5 13,4 13,3 13,2 13,1 Table 3 Switching Power Supply Output Voltage chart. To find the Output Voltage using the chart: — select the near- est value to the Probe temperature on the TEMPERATURE (°C) row; read the corresponding value on the VOLTAGE (V) row; adjust the Output Voltage of the Switching Power Supply to the indicated value. For example, if the Probe tem- perature is 22 °C, the Output Voltage of the Switching Power Supply must be set at 13.7 V.

You can program the system using a LCD Keypad, or

using the KYO300-KYO100 downloading software from the Bentel Security Suite Software package (ac- cessory item). � You CANNOT program the Hardwired Zone Sen- sitivity and Scheduler parameters — except for the Max. no. overtime requests and Overtime Request options — from the Keypad. You can record and playback Voice Messages, and program the Key/Card Codes ONLY from a Keypad. If you are programming the system from a Keypad, refer to the instructions in the “PROGRAMMING FROM KEYPAD” manual. � This section provides information on the system parameters, and should be referred to also when programming from a Keypad. Read this section thoroughly to learn how to install and use the KYO100-KYO300 software application. 1. Install the KYO100-KYO300 software application as described in the Security Suite manual. 2. Run the KYO100-KYO300 application. 3. Select the Control panel Type (refer to the Cus- tomer data paragraph) and the Firmware Release (refer to the Options paragraph in the Security Suite manual). 4. NOTE: When programming the KYO 100, select File > INIT then setup the Panel Type and Firm- ware Release in the Parameters window. 5. Program the parameters (refer to the relevant para- graphs for instructions). 6. Download the programmed parameters (refer to the relevant paragraph: On-site Programming via Computer or Remote Programming via Com- puter). � The programmed parameters can be saved on hard or floppy disk, and downloaded to the Control panel via modem or on-site. The programmed pa- rameters can be renamed and reused for different Customers (refer to “Save” and “Open Customer” in the “Bentel Security Suite” Manual). The system parameters are organized in Pages. The Programming Pages in this section are congruent with the KYO300 software structure. Configuration (Enrolling Devices) On startup the Control panel will automatically enrol all the BPI Bus peripherals (refer to “Power supply connec- tion” under “INSTALLATION”). Any changes after auto- matic enrollment must be made by the Installer. During the polling process, the Control panel will match the interrogation result with the stored configuration and, in the event of mismatch, will generate the relevant warning. � If the Control Panel is connected to a computer, it will be possible to view the configuration by loading the Configuration page. The Configuration section is divided into pages — one for each type of device (Keypads, Input Expanders, Output Expanders, Readers, Power Supply Stations and Accessories). The following programming instructions refer to param- eters common to all BPI devices. For instructions on how to program the parameters of a specific device, re- fer to the relevant paragraph. KYO 300-KYO100 PROGRAMMING 31

� The devices connected to the BPI Bus must be Se-

lected, otherwise the system will be unable to enrol them. � The Select button (on the bottom of the page) will allow you to select/deselect all the devices on the page at once. The Control panel cannot manage unenrolled peripher- als. If a peripheral device has not been connected properly to the BPI bus, or fails to respond (Device Lost) due to Trouble or Tamper, an X will be shown above the s icon on the Keypad, and the Control Panel will generate the relevant event, as follows: � Warning Readers = Lost Device � Warning BPI Input Expander = Lost Input Ex- pander � Warning Keypads = Lost Keypad � Warning Output Expanders = Lost Output Ex- pander � Warning Power Stations = Lost Power Station � The event will be recorded in the Logger (refer to ID.TYPE for the BPI Device Lost event). No. This field shows the Identifier number of the de- vice. The Identifier number of a BPI Device is also the device Address (refer to “Assigning Addresses” under “Connecting BPI Devices” in the “INSTALLATION” sec- tion). Description This editable field (maximum 16 charac- ters) is for the device label (e.g. Entrance, Kitchen, etc.). This Description will identify the Device in all the operations it is involved in. � Keypads Page The Keypads page will allow you to set up Mia-D, Alison-DV and Alison-S Keypads. The Page layout is as follows. � For information regarding the �, No. and Descrip- tion parameters, refer to the “Configuration” sec- tion. Enabled on Partitions Select the Keypad Partitions. The Keypad will be able to control (Arm, Disarm, etc.) ONLY the Enabled Partitions. � Keypads need not necessarily be enabled on Parti- tions, and can be used for programming, viewing and other non-command related purposes. The Partitions button (bottom of the window) will allow you to deselect the Partitions (None), select all the Par- titions (All), or invert the current setting (Toggle). Quick Arm Code Select the Code that will be used for Quick Arming (refer to “Quick Arm” in the USER MANUAL). A The IMQ SECURITY SYSTEM Approval applies only when the “Quick Arm” feature IS NOT USED FOR DISARM operations. Memo Keypads with this attribute will be able to record and play back Voice Messages. Quick viewing of Partition status If this option is en- abled, it will be possible to view the status of ALL the Keypad Partitions by pressing the ON key (refer to “Fast Status Enquiry” in the USER MANUAL). � If Partition Alarm or Tamper is present the respec- tive character will blink. Alarm/Tamper Beep If this option is enabled, the Key- pad will emit an audible signal (beep), when Alarm or Tamper is detected on any of its Partitions. Viewable Partitions Select the Partitions (1 through 32) that will be shown on the Keypad in question. At default, 32 Figure 27 Keypads page

the first eight characters on the second line of the dis-

play correspond to Partitions 1 through 8. � The Partitions must be selected in successive or- der, therefore, if Partition no. 5 is selected first, Par- titions no. 1 through no. 4 cannot be selected. � LED Keypads The LED Keypads page will allow you to set up LED Keypads. � For information regarding the �, No. and Descrip- tionparameters, refer to the “Configuration” section. � Input Expanders The Input Expanders page will allow you to set up the Input Expanders. � For information regarding the �, No. and Descrip- tionparameters, refer to the “Configuration” section. � Output Expanders The Output Expanders page will allow you to set up the Output Expanders. � For information regarding the �, No. and Descrip- tionparameters, refer to the “Configuration” section. � Readers The Key/Card Readers will allow Users to: � Arm Partitions � Disarm Partitions � Arm in A and B Mode � Stop Partition Alarms � Commands will affect ONLY the Partitions com- mon to both the Reader and Key/Card in use. For example, if you attempt to Arm the system at a Reader that is enabled on Partitions no. 1 and no. 2, with a Key/Card that is enabled on Partitions no. 1 and no. 3, ONLY Partition no. 1 will Arm (Partition no. 1 is common to both the Reader and Key/Card). The Readers page will al- low you to set up the Readers, as follows. � For information regarding the �, No. and Descrip- tionparameters, refer to the “Configuration” section. M This attribute will enable the Reader for Monitoring purposes (i.e. To signal specific events — to be pro- grammed by the Installer). � Monitoring Readers (Readers with the M attrib- ute) CANNOT be used for system control purposes but will be able to generate Valid Key, Key at Reader events and Valid Key on Partition. The Expand button at the bottom of the page will open the Readers table. If you are programming System Control Readers: select the Reader Partitions, and set up the A and B Mode Arming configurations (refer to the following paragraphs). If you are programming Monitoring Readers: select the Events to be monitored (refer to the following paragraphs). RED spot This row will allow you to assign (�) the Reader to the Partitions (01 through 32). To view the Partition Description: click the Descrip- tion button (bottom of page) then position the cursor on the Partition check box. To highlight a Reader: hold down the SHIFT key and click anywhere on the Reader table, then release the SHIFT key. To highlight a group of Readers: hold down the SHIFT key and click anywhere on the tables of the first and last Readers of the group, then release the SHIFT key. To assign the Reader Partitions (quick mode): highlight the relevant Reader, click the Partitions button then select: None — to Disable the highlighted Readers on all Par- titions; All — to Enable the highlighted Readers on all Parti- tions; Toggle — to invert the current status of the highlighted Readers. To Copy data (Enabled Partitions, A and B Mode Arming configuration): highlight the Reader to be cop- ied; right click the mouse; select Copy from the pop-up menu; highlight the Readers to be pasted; right click the mouse, then select Paste from the pop-up menu. YELLOW spot This programming section will allow you to set up the A Mode Arming configuration. If an A Mode Arming request is made at a Reader, the Parti- tions will Arm/Disarm in accordance with the pro- grammed configuration, as follows: � D — the corresponding Partition will Disarm � N — the status of the corresponding Partition will re- main unchanged (None) � A — the corresponding Partition will Arm � S — the corresponding Partition will Arm in Stay mode (i.e. Zones with the Internal Attribute will be Bypassed). � I — the corresponding Partition will Arm in Instant Mode (Stay with zero Entry Delay) GREEN spot As per the YELLOW spot but for B Mode. � Monitoring Readers(Readers with the M attribute) CANNOT be used for system control purposes. Event no. This programming section will allow you to set up the Monitoring Readers events will be able to signal. Enter the Identifier Number of the Event that is to be signalled on the LED, or double-click and select the Event from the Events list, then click OK. � The Event no. section is for Monitoring Readers ONLY (Readers with “M” attribute). KYO 300-KYO100 PROGRAMMING 33

� Power sta

The Power stations page will allow you to setup the system Power Stations. � For information regarding the �, No. and Descrip- tion parameters, refer to the “Configuration” sec- tion. Mains fault warning delay This programming field will allow you to set the Mains fault warning delay (in seconds). Interruption of the Mains power supply to the Power station will trigger the programmed de- lay. If power is not restored before the delay ex- pires, the Control Panel will signal Mains fault. Low battery delay This programming field will allow you to set the Low battery delay (in seconds). If the Power station battery voltage drops below 11.4 V, the Control Panel will trigger the programmed delay. If the Voltage is not restored before the delay expires, the Control Panel will signal Low battery. Valid entries: 1 through 3932 seconds (60 min. 32 sec.). Default setting: 180 seconds The Control Panel can detect and signal: � forced opening or removal of Power stations � interruption of power supply to the Power stations � the status of Power station batteries � the status of Power supply modules � the status of Power station Outputs Forced opening or removal will be signalled by: � the Tamper Power stations event (refer to “Events-Actions” section) � an X above the b icon on the Keypad � the Event details in the Logger TYPE — Tamper BPI EVENT ID. — The Power Station label (Description) Mains power failure (interruption) will be signalled by: � the Warning mains failure on Power station event (refer to “Events-Actions” section) � the ON status of the G LED on the keypads, and the AC Mains Failure message (refer “View Trou- ble Mode” in the USER MANUAL) � the Event details in the Logger TYPE — AC Mains Failure EVENT ID. — The Power Station label (Description) Low Battery (below 11.4 V — refer to “Static Test” under “Connecting Power supplies” in the “IN- STALLATION” section) will be signalled by: � the Warning low battery on Power station event (refer to “Events-Actions” section) � the ON status of the G LED on the keypads, and the Low Battery message (refer “View Trouble Mode” in the USER MANUAL) � the Event details in the Logger TYPE — Low Battery EVENT ID. — The Power Station label (Description) Battery Trouble (refer to “Dynamic Test” under “Con- necting Power supplies” in the “INSTALLATION” sec- tion) will be signalled by: � the Warning power trouble on Power station event (refer to “Events-Actions” section) � the ON status of the G LED on the keypads, and the Troub. pow. syst. message (refer “View Trou- ble Mode” in the USER MANUAL) � the Event details in the Logger TYPE — Troub. pow. syst. EVENT ID. — The Power Station label (Description) Disconnected Battery2 will be signalled by: � the Battery not connected on Power station event (refer to “Events-Actions” section) � the ON status of the G LED on the keypads, and the Batt. disc. pw.s message (refer “View Trou- ble Mode” in the USER MANUAL) � the Event details in the Logger TYPE — Batt. disc. pw.s EVENT ID. — The Power Station label (Description) Power supply module trouble3 will be signalled by: � the Battery charger trouble on Power station event (refer to “Events-Actions” section) � the ON status of the G LED on the keypads, and the Fault chrg.pw.s message (refer “View Trouble Mode” in the USER MANUAL) � the Event details in the Logger TYPE — Fault chrg.pw.s EVENT ID. — The Power Station label (Description) 34 2 If the battery voltage drops below 10.2V, the Power station will disconnect it automatically. This operation will prevent damage to the battery. 3 The Power supply module of the Power station will be considered “out-of-order” if its output voltage reaches 0.5V above, or drops to 0.5V below the preset value. If the Power station is not equipped with a Thermal probe, the output voltage will be 13.8V. If the Power station is equipped with a Thermal probe, the output voltage will depend on the probe temperature.

Disconnected Power supply module4 will be signalled

by: � the Switching not connected on Power station event (refer to “Events-Actions” section) � the ON status of the G LED on the keypads, and the Swtch.disc.pw.s message (refer “View Trouble Mode” in the USER MANUAL) � the Event details in the Logger TYPE — Swtch.disc.pw.s EVENT ID. — The Power Station label (Description) Current draw of a Power station output that exceeds the maximum will be signalled: � the Short circuit output ½/3 on Power Station event (refer to “Events-Actions” section) � the ON status of the G LED on the keypads, and the Out. short pw.s message (refer “View Trouble Mode” in the USER MANUAL) � the Event details in the Logger TYPE — Out. short pw. s EVENT ID. — The label (Description) of the relevant Power Station AGENT: Output number � Accessories The Accessories page will allow you to set up the Wire- less Receiver, Auxiliary Communicator, Voice boards and Printer interface. Wireless module The Present option MUST BE ENABLED, if a VectorRX Receiver is connected to the Control Panel KEY bus. � The Control Panel will enrol the Receiver as soon as it is connected to the Key bus. However, the Wireless module option must be enabled manu- ally, otherwise, it will be impossible to program the wireless devices (refer to “Wireless”). Transmission trouble between the Control Panel and Receiver (due to Fault or Tamper) will be signalled by an X above the s icon on the Keypad, and by the Warning wireless device event. � Receiver Trouble and Lost BPI devices will be sig- nalled in the same way ( X above the s icon on the Keypad. If the signal is due to Receiver Trou- ble, the Keypad will display the Receiver Lost message in the TYPE field in the Events Logger (refer to “Events Logger” in the KEYPAD PROGRAMMING MANUAL). Disable the Present option to clear the Receiver Trou- ble warnings. Time Supervision Zones This programming field will allow you to program the supervisory time for the Su- pervised Wireless Zones (refer to “Supervised” under “Wireless” ). Each wireless zone should send a supervi- sory signal within a programmed interval. If the Re- ceiver does not receive the signal it will generate a Lost wireless zone event. Valid entries: 2 hours and 30 minutes (at default) to 24 hours (in 15-minute steps). A The IMQ SECURITY SYSTEM Approval applies only when the Time Supervision Zones window is set at 2 hours 30 minutes, and the Supervised op- tion is Enabled for ALL the Wireless zones (refer to “Wireless”). Disable Jamming If the system detects RF jamming, and this option is DISABLED (at default), it will be sig- nalled by an X above the b icon on the Keypad, and by the Tamper wireless device event. � Jamming and BPI Device Tamper will be signalled by X above the b icon on the Keypad. Jamming and Receiver Tamper will be signalled by the Tam- per wireless device event. If the signal is due to Receiver Tamper (jamming, opening or removal) the WLS Tamper event will be logged. KYO 300-KYO100 PROGRAMMING 35 4 The Power station will disconnect the Power supply module if its output voltage reaches 0.5V above the preset value.This operation will prevent damage to the peripherals. The power to the peripherals will be provided by the Power station battery. If the Power station is not equipped with a Thermal probe, the preset output voltage will be 13.8 V. If the Power station is equipped with a Thermal probe, the output voltage will depend on the probe temperature.

Auxiliary Communicator The KYO 300 (only) will en-

rol the Auxiliary Communicator as soon as it is con- nected to the Keybus. Transmission trouble between the Control and Auxiliary Communicator (due to Fault or Tamper) will be signalled on the G LED (ON) and by the Trouble auxiliary communicator (VDS) event. � The G LED signals several different Trouble events. If the signal is due to loss of the Auxiliary Communicator, the Keypad (in View Trouble Mode) will show the AuxCom Lost message (re- fer to “View Trouble Mode” in the USER’S MANUAL). To clear the Auxiliary Communicator Trouble warn- ings— select the Not present option. VOX board The Control Panel will enrol the Voice board as soon as it is connected to the Keybus. Trans- mission trouble between the Control panel and Voice Board (due to Fault or Tamper) will be signalled on the G LED (ON). � The G LED signals several different Trouble events. If the signal is due to loss of the Voice Board, the Keypad (in View Trouble Mode) will show the Vox Board Lost message (refer to “View Trouble Mode” in the USER’S MANUAL). Disable the Present option to clear the Voice board Trouble warnings. Print logger If this option is enabled the Control panel will printout the events as they occur (real-time print- out). � This feature is provided by the optional K3-PRT Printer Interface (refer to “K3-PRT Printer Inter- face” in the APPENDIX). Only Enabled events can be printed (refer to “Log- ger — Event settings”). Add line feed Enable this option, if there are over- lapped lines on the printout. Disable this option, if there are empty lines between events. Hardwired Zones The hardwired Zones can be used for system monitor- ing (Alarm Zones), or management (Control Zones). Alarm Zones If Alarm conditions are detected, the Alarm Zones will generate the relevant event (refer to “Type”). The Events-Action page will allow you to as- sociate each event with one or more actions (activation of Hornstrobes, Digital Communicator, Dialler, etc.). The system cannot generate an Alarm event until the Par- titions the Zone is assigned to Arm5 (refer to “Partitions”). � This does not apply to 24h and Fire Zone events, as these events do not depend on Partition status. If the zone is NOT an Exit Delay or Last Exit Zone (re- fer to “Type”) the Control Panel will start monitoring as soon as the Partitions the Zone is assigned to Arm5, otherwise, it will start monitoring when the longest Exit Time of the Armed Partitions the Zone is assigned to ends (refer to “Partitions”). The system will generate an Alarm when the voltage on the Zone terminal falls within the Alarm voltage range (refer to “Voltage Ranges”) for the programmed num- ber of times and/or length of time (refer to “Sensitivity”). Each Alarm Zone can generate the Zone Alarm event for the programmed number of times (refer to “Cycles”). Command Zones Each Command Zone can be pro- grammed to activate one of the following actions: � Switch Partition status � Arm and Disarm Partitions � Arm Partitions only � Disarm Partitions only � Reset Partitions � Reset Control Panel � Cancel telephone calls � Not Ready to Arm � Ready to Arm A The IMQ SECURITY SYSTEM Approval applies only when the Auxiliary command devices — used for Partition Arm/Disarm operations via Command Zones — are IMQ Security Systems Grade II Listed, and their Auxiliary command modules are housed inside the Control Panel. The Command Zones will activate when they are unbal- anced (refer to “Balance”) for the programmed number of times or length of time (refer to “Sensitivity”). The BPI Zones page will allow you to program the Hardwired Zones (for Wireless Zones refer to the “Wire- less” paragraph). 36 5 If the Full Arming alarm option is enabled, ALL the Partitions the Zone is assigned to must be Armed. If the Full Arming alarm option is disabled, AT LEAST ONE of the Partitions the Zone is assigned to must be Armed.

The chart on the left side of the BPI Zones page shows

the available hardwired Zones (refer to “Configuration”). The following information will be shown for each Zone. No. This field shows the Zone ID number that will be used (instead of the Zone Description) in some parts of the application (refer to “Description”). Position This field shows the Description of the hard- ware component the Zone is assigned to. This label can be edited on the Configuration page. � The Position of the Control panel Zones (Main Unit) is non-editable. Device This field shows the ID number (Address) of the device the Zone is assigned to. A hyphen indicates that the Zone is assigned to the Control Panel. Ter. This field shows the Zone terminal tag. Description This 16 character field will allow you to as- sign and/or edit the Zone Description. The label will identify the Zone in all parts of the Software Application. The chart on the right-hand side of the BPI Zones page will allow you to change the Zone settings. The Zone must be selected from the Zones list. � Type The Type determines the affect the Armed/Disarmed status of the system will have on the Alarm signals, and whether the Zone will trigger Alarms immediately or af- ter a programmed delay. � All Zones — other than Fire and 24h — will be clas- sified as Burglar. Instant Violation (refer to “Balance”, “Voltage Range” and “Sensitivity”) of an Instant Zone — that is not Unbypassed or in Test status (refer to “Attributes”); has not run its programmed Cycles (refer to “Cycles”), and whose Partitions are Armed6— will generate the follow- ing events: � Alarm on zone (related to the Zone in question); � Burglar alarm partition, Generic alarm on parti- tion and Generic+Tamper alarm on partition — relative to the Armed Partitions of the Zone; � Burglar alarm on panel, Generic alarm on panel and Generic+Tamper alarm on panel. Entry delay Violation of an Entry Delay Zone — that is not Unbypassed or in Test status; has not run its pro- grammed Cycles, and whose Partitions are Armed6 — will trigger the longest Entry Delay of all of its Parti- tions. All the associated Keypads will beep until the de- lay expires. If the Partitions the Zone is assigned to are not Disarmed7before the delay expires, or if the Zone is violated after the Delay, the system will generate the Events associated with the Instant Zones. The first Zone on the path to a Disarm point (Reader or Keypad) should be programmed as an Entry delay Zone. Entry path Violation of an Entry path Zone — after vi- olation of an Entry delay zone — will trigger the Events associated with the Instant Zones, as soon as the pro- grammed Entry delay expires. If the Entry Time is not active, or has expired, the system will generate the Events associated with theInstant Zones. The Zones leading to a Disarm point (Reader or Key- pad) should be programmed as Entry path Zones. KYO 300-KYO100 PROGRAMMING 37 Figure 28 BPI Zones page 6 If the Full Arming alarm option is enabled, ALL the Partitions the Zone is assigned to must be Armed. If the Full Arming alarm option is disabled, AT LEAST ONE of the Partitions the Zone is assigned to must be Armed. 7 If the Full Arming alarm option is enabled, AT LEAST ONE of the Partitions the Zone is assigned to must be Armed. If the Full Arming alarm option is disabled, ALL the Partitions the Zone is assigned to must be Disarmed.

Exit delay Violation of an Exit delay Zone — during

the Exit Time of its Partition — will not trigger any events. In all other cases, the system will generate the Events associated with the Instant Zones. The Zones leading out of a Partition should be pro- grammed as Exit delay Zones. Last exit Violation of a Last Exit Zone — during the Exit Time of its Partition — will not generate any Events but will clear any residual Exit Time, and trigger the programmed Last Exit Time of its Partition. In all other cases, the system will generate the Events associated with the Instant Zones. This feature will allow the system to Arm as soon as the programmed Last Exit Time expires. The last Zone leading out of a Partition should be pro- grammed as a Last Exit Zone. 24h Violation of a 24h Zone — regardless of the status of its Partition (Armed/Disarmed) will generate the fol- lowing events: � Alarm on zone (relevant to the Zone in question); � 24h alarm on partition, Generic alarm on partition and Generic+Tamper alarm on partition — rele- vant to the Partition the Zone is assigned to; � Tamper alarm on panel, Generic alarm on panel and Generic+Tamper alarm on panel. 24h Zones NEED NOT necessarily be assigned to Par- titions. In which case, they will generate only: � Alarm on zone (relevant to the Zone in question); 24h Zones that are not assigned to Partitions can be used for control applications, such as switching on courtesy lights (using infrared sensors). � 24h Zones which are not assigned to Partitions must be programmed as Repetitive (refer to “Cycles”). Fire Violation of a Fire Zone — regardless of the sta- tus of its Partition (Armed/Disarmed) will generate the following events: � Alarm on zone (relevant to the Zone in question); � Fire alarm on partition, Generic alarm on parti- tion and Generic+Tamper alarm on partition — relevant to the Partition the Zone is assigned to; � Fire alarm on panel, Generic alarm on panel and Generic+Tamper alarm on panel. Duress Violation of an Unbypassed Duress Zone which is not in Test status, and has not run its programmed cy- cles will generate the following Instant Events8: � Alarm on zone (relevant to the Zone in question); � Panic alarm on partition (VDS) no.—relevant to the Partitions the Zone is assigned to. Moreover, the Keypad: � WILL NOT signal Alarms triggered by Duress Zones (the a indicator WILL NOT blink). � WILL NOT signal outgoing calls triggered by Duress Zones (X WILL NOT appear above the i icon). � Command If a Command Zone triggers an Alarm (see “Balance”, “Voltage Range” and “Sensitivity”), the system will gen- erate the programmed Actions. In all other cases (Tam- per and Short Circuit) it will operate as an Alarm Zone. Command Zones will be active at all times, regardless of the status of their Partitions (Armed/Disarmed). Arm/Disarm/Toggle If this command is enabled, all the Partitions the Zone is assigned to will change status when the Zone triggers an Alarm — Armed Partitions will Disarm and visa versa (refer to “Partitions”). Arm/Disarm/Bistable If this command is enabled, all the Partitions the Zone is assigned to will Arm — when the Zone triggers an Alarm, and Disarm — when it re- stores to standby. � Partitions — Armed by an Arm/Disarm/Bistable Com- mand Zone — cannot be Disarmed until all the Zones of that type are in standby status (and CANNOT be Disarmed via Keypad, Reader, Telephone or PC). Arm only If this command is enabled, all the Partitions the Zone is assigned to will Arm when the Zone triggers an Alarm. Disarm only If this command is enabled, all the Parti- tions the Zone is assigned to will Disarm when the Zone triggers an Alarm. Partition Reset If this command is enabled, all the Partitions the Zone is assigned to will Reset when the Zone triggers an Alarm. Panel Reset If this command is enabled, the Control panel will Reset when the Zone triggers an Alarm. Clear Call Queue If this command is enabled, the Call Queue will be cleared when the Zone triggers an Alarm. Extended Not Ready-to-Arm If this command is en- abled, the Zone will trigger a Not Ready-to-Arm parti- tion event — relevant to its Disarmed Partitions. Extended Ready-to-Arm If this command is enabled, the Zone will terminate the Extended not Ready-to-Arm partition event — relevant to its Dis- armed and Armed (Away mode) Partitions. 38 8 The Duress Zone will generate its respective events, regardless of the status of the Partitions it is assigned to.

� If the Partition of the Zone is Disarmed, the Ex-

tended not Ready-to-Arm partition event will ter- minate when ALL the trigger events terminate (refer to Extended not Ready-to-Arm partition event under “Events-Actions”). When the Zone restores to standby, it will generate an Extended not Ready-to-Arm partition event — rele- vant to its Disarmed Partitions. � If the Partition of the Zone is Armed in Away mode, the Extended not Ready-to-Arm partition event will terminate when the Extended Ready-to-Arm Delay expires (refer to “Extended Ready-to-Arm Delay” under “Partitions”). � Attributes � The following attributes apply to Alarm Zones ONLY. Unbypassable Zones with this attribute cannot be By- passed. Chime Violation of a Zone with this attribute — during Disarmed status of its Partition will generate the Chime on partition no. event, and an audible signal (beep) on the assigned Keypads. Violation of a Chime Zone — during Armed status of its Partition will trigger the Ac- tions programmed for the Type parameter. � The Chime Attribute is ineffective on 24h and Fire Zones. Test Violation of a Zone with this attribute will not generate the Alarm on zone no. event. However, the “Alarm - Zone under test” message will be recorded in the Control panel Logger. The Test phase will allow you to check the functionality of the Zones without triggering Alarm signals. At default, the Control panel will record ONLY the Events that occur during Armed status. How- ever, by means of the relevant option, events that occur during Disarmed status can also be recorded (refer to the Options page). � The G LED on the keypad will blink when there is one or more Unbypassed Zones is in Test status. Autobypassable Zones with this attribute will be by- passed automatically, if violated during Armed status of their Partitions. They will be unbypassed when their Partitions are Disarmed. � The Autobypassable attribute is ineffective on Delayed Exit Zones. A The IMQ SECURITY SYSTEM Approval applies only when the Enablement of the Autobypassable attribute is Disabled for Zones with Intrusion, Tamper or Burglar detection. Autobypass with Reset Unbypass Zones with this attribute will be bypassed automatically, if violation oc- curs when their Partitions are Armed. They will be unbypassed when standby is restored. A The IMQ SECURITY SYSTEM Approval applies only when the Autobypass with Reset Unbypass attribute is Disabled for Zones with Intrusion, Tam- per or Burglar detection. Stay Zones with this attribute will be bypassed when their Partitions Arm in Stay mode or Stay with Zero De- lay mode. Delayed on Stay Arming This Attribute can be as- signed to Entry Path Zones ONLY. Zones with this at- tribute will operate as Delayed Entry Zones when AT LEAST ONE of their Partitions is in Stay mode. Delayed and Estimated on Ready to Arm This At- tribute can be assigned to Delayed Exit and Last Exit Zones ONLY. If a Zone with this Attribute is NOT in standby status when the system receives a command to Arm one of its Partitions, it will generate a Not Ready to Arm event. � Balance Type The Balance Type determines the electrical state (on the Zone input terminal) that will trigger Alarms. � The following electrical states must be present on the Zone Input terminals for at least 0.3 seconds. Normally Open Zones with this attribute will trigger Alarms when they short to Negative (e.g. Fire detectors). A The IMQ SECURITY SYSTEM Approval applies only when the Zones are programmed as Normally Closed (Normally Open Zones are not protected against wire cutting). Normally Closed Zones with this attribute will trigger Alarms when they Open. A If Zones are programmed as Normally Closed, the IMQ SECURITY SYSTEM Approval will be down- graded from Grade II to Grade I (Normally Closed Zones are not protected against short circuits). KYO 300-KYO100 PROGRAMMING 39

10K If you apply this Balance Type, the Control panel

will consider the Zone in standby status, when the 10 K resistor (10,000 ohm) is connected between the Zone terminal and Negative. If a 10K Zone shorts to Nega- tive, the Control panel will detect Tamper conditions and generate the following events: � Tamper on zone (relative to the zone in question); � Tamper alarm on partition no. and Generic+Tam- per alarm on partition no. relevant to the Partition the Zone is assigned to; � Tamper alarm on panel and Generic+Tamper alarm on panel; In all other cases (Unbalancing, Open, etc.) the Control panel will signal violation (refer to “Type”). Double If you apply this Balance Type, the Control panel will consider the Zone in standby status when the two 10 K resistors (10,000 ohm) are connected in paral- lel between the Zone terminal and Negative. If one of the resistors disconnects, the Control panel will generate the events associated with the Zone Type (re- fer to “Type”). In all other cases (Zone Open, Con- nected to Negative, etc.), the Control panel will detect Tamper conditions and generate the Events associated with 10K Balance Zones. This Balance Type (using 2 wires) will allow the system to detect open Alarm and Tamper contacts (refer to “Connecting to a Double Balance zone”). Glass Break You must apply this Balance Type to Zones with Glass Break Detectors. 10K Alarm Only If you apply this Balance Type, the Control panel will consider the Zone in standby status when the 10 K resistor (10,000 ohm) is connected be- tween the Zone terminal and Negative. The Control panel will consider all other conditions as violation (Zone open, short-circuit, etc.). 10K Alarm Only Balance Zones will signal Alarm sta- tus when shorted. 10K Balance Zones will signal Tamper status when shorted. Customized You can customize this Balance Type to suit the system requirements (refer to “Threshold”). � Threshold The voltage threshold values will allow the Control Panel to detect and distinguish Zone Alarm, Tamper and Short-circuit conditions. If you apply Customized Balance, you will be able to select the various thresholds (Standby, Alarm, Tamper and Short circuit). Value in ohm This option will allow you to view the zone terminal voltage values (instead of the threshold % values). Standby If you enable this option, the Control panel will consider the Zone in Standby status when the volt- age on its terminal is below the programmed Standby threshold. Alarm If you enable this option, the Control panel will consider the Zone in Alarm status when the voltage on its terminal exceeds the programmed Alarm threshold for the programmed interval, and number of times (re- fer to Sensitivity). Tamper If you enable this option, the Control panel will consider the Zone in Tamper status when the voltage on its terminal exceeds the programmed Tamper threshold for at least 0.3 seconds (300 ms). Short-circuit If you enable this option, the Control panel will consider the Zone “Shorted” when the voltage on its terminal exceeds the programmed Short-circuit threshold for at least 0.3 seconds (300 ms). Thresholds Valid entries: 1% through 98% in steps of 1% (equal to 138 mV with a 13.8V Power supply). The thresholds must be programmed with rising values. � In order to ensure maximum immunity to voltage changes, the thresholds are expressed in percent- age of the Zone power voltage. The Zone Status option (from the INSTALLER MENU) will allow you to view the Zone voltages (refer to “Zone Status” in the “KEYPAD PROGRAMMING MANUAL”). � The Threshold parameter is protected against un- intentional changes. To change the Threshold values, select the button. � Inactivity This function allows the system to monitor Alarm Zone inactivity (non-detection of motion), when the Partitions are Disarmed. The Inactivity function provides protection against the Detector blinding and allows the system to detect Zone malfunction. Under normal circumstances, Users dis- arm the system when they are on the premises, there- fore, the Zones should detect motion (violation) quite frequently. If this does not occur, the system will sup- pose that the User is unable to move (due to serious ill- ness, accident or delinquency) and as a result will generate a Delinquency on Partition event, thus prompting the Central station operator to take the nec- essary action. The Inactivity function can also be applied to automatic Arming. In which case, if the Zone does not detect mo- tion (violation) for the programmed period the system will suppose that no Users are present and will Arm the Partitions the Zone belongs to. � The system will monitor Zone Inactivity ONLY when ALL the Partitions of the Zone are Dis- armed. 40

The Inactivity field will allow you to set the Inactivity pa-

rameters, as follows: None If you enable this option, Zone Inactivity will not be signalled. All Zones are disabled at default. Inactivity If you enable this option, Zone Inactivity will be signalled when the programmed Inactivity Time expires. Zone Inactivity will be signalled by: � the Event delinquency on partition — relating to the Partitions the Zone is assigned to. � The G LED (ON) signals several different types of Trouble events. If the signal is due to Inactivity, the Keypad (in View Trouble Mode) will show the In- activity message (refer to “View Trouble Mode” in the USER’S MANUAL). The following information will be recorded in the Event Logger: � TYPE: Inactivity � ID. EVENT: Description of the Partitions the Zone is assigned to; � AGENT: None; � ID. AGENT: Description of the Zone that triggered the Inactivity event. Zone Inactivity will terminate when the Zone restores standby, or when the Zone triggers an Alarm. The termination of a Zone Inactivity event will be sig- nalled on the G LED (OFF) on Keypads which are en- abled on at least one of the Partitions the Zone belongs to. � The G LED switch OFF ONLY when there are no Inactive Zone or Trouble signals relating to the Keypad Partitions. As the event is a Spot event, the termination of a Zone Inactivity event will not be signalled. Auto-arm on delay If you enable this option, the Parti- tions the Zone belongs to will Arm automatically when the programmed Inactivity Time expires (refer to Inac- tivity Time/Delay). Inactivity Time/Delay This field will allow you to pro- gram the Inactivity window (i.e. the time the system will allow the Zone to be inactive). Valid entries: 1 through 14400 minutes (10 days) 1-min- ute steps. At default, the Inactivity Time is 1 minute. � The programmed Inactivity Time will reset when: — ALL the Partitions the Zone belongs to Disarm; — the Zone is violated; — the Zone Restores to standby. � Cycles This parameter determines the number of times the Zone will be able to trigger the Zone Alarm event. Valid entries: 0 through 254 or Repetitive: � If 0 is selected, the Zone will be unable to trigger Zone Alarm events; � if any number other than 0 is selected, the Zone will be able to trigger the corresponding number of Alarm events; � if Repetitive is selected, the Zone will be able to trig- ger an unlimited number of Zone Alarm events. The Zone Alarm Cycle counter will reset when: � one of the Partitions of the Zone changes status; � one of the Partitions of the Zone Resets; � one of the Partitions of the Zone exits Block Alarm status; � the programming session ends (i.e. when you exit the Installer Menu or complete downloading via the PC); � the Zone is Unbypassed. � A Zone that signals a persistent Alarm condition (e.g. due to Trouble conditions) will generate one Alarm cycle ONLY, in compliance with CEI 79/2 regulations. It will be unable to generate further cy- cles until the Alarm counter has been cleared. � Partitions This table will allow you to assign the Alarm and Com- mand Zones to the Partitions. For Alarm Zones — The selected Partitions will deter- mine which User Codes, Digital Keys/Cards and Oper- ating Times will be associated with the Zone. Each Alarm Zone can be assigned to more than one Partition. � If the Zone is a Delayed Zone (Entry Delay, Path, Exit Delay or Last Exit Delay), the system will apply the longest Entry Delay, Exit Delay or Last Exit De- lay of all its Armed Partitions. For Command Zones — The selected Partitions will de- termine which Partitions the Zone will be able to control. Each Command Zone can operate on more than one Parti- tion. Full Arming Alarm If this option is enabled, the Zone will be able to generate the Alarm on Zone event ONLY when ALL of its Partitions are Armed. If this option is disabled, the Zone will be able to gener- ate the Alarm on Zone event even when AT LEAST ONE of the Partitions it is assigned to is Armed. � Sensitivity The system will signal Zone Alarm status when the volt- age on the Zone terminal exceeds the Alarm threshold for the programmed interval (Within), and/or number of times (Pulses). This section will allow you to program amount of time (Length) and/or the number of times (Pulses), as follows. Standard This field will allow you to set the number of Pulses that will trigger Alarm status. Valid entries: 1 to 3 pulses from 100 ms (0.1 seconds) through 1000 ms (1 second) in steps of 100 ms (0.1 seconds). KYO 300-KYO100 PROGRAMMING 41

If you set more than 1 Pulse, you will be able to set the

Within time (i.e. the interval within which the pro- grammed number of Pulses must occur), and select whether the system will signal Zone Alarm when: — Pulses are detected within the set time (Alarm for n pulses within t Sec., where n stands for the number of Pulses and t the programmed Within time), or when: — 1 pulse is detected which is longer than the pro- grammed Within time (OR single pulse with length > t Sec., where t stands for the programmed Within time). Low This field will allow you to set the minimum Pulse length. If you select Step 500 ms, you will be able to set a Pulse length of 0.5 through 32 seconds in 0.5 second steps. If you select Step 30 sec., you will be able to set a Pulse length of 30 through 1920 seconds (32 minutes) in 30 second steps. � If you select the Step 30 sec. option, the Control panel will round off the Pulse length to the nearest 5 seconds. For example, if you set 30 seconds, the Control panel will trigger an Alarm when it detects a Pulse between 25 and 30 seconds. A The IMQ SECURITY SYSTEM Approval applies only when the Length parameter of Zones with In- trusion, Tamper or Burglar detection devices does not exceed 400 milliseconds; and/or the Within pa- rameter is more than 30 seconds. � Voice Messages This feature is provided by the K3-VOX kit (optional Voice Board + Speaker). If this optional feature is avail- able, you will be able to assign two voice messages to the Zone. These messages will allow the User to make status enquiries (with voice answer) over the phone. The Voice Messages can be recorded, played and de- leted at the Keypad (refer to “Voice Messages”). Standby This field will allow you to select the Message which will be played when the Zone is in Standby sta- tus. � If no message is selected, Standby status will be signalled by a Beep. Alarm This field will allow you to select the Message which will be played when the Zone is in Alarm, Tamper or Short Circuit status. � If no Voice Message is selected, Zone Alarm will be signalled by two Beeps. Zone in AND Mode This option will allow you to set up the system to gener- ate Alarms when violation occurs on a specific group of Zones within a set time. No. This field shows the Identifier number of the AND Zone group. Window This field will allow you to set the time within which ALL the Zones of the respective group must de- tect violation. The And Zones page will allow you to set up to 32 Groups, each with: � up to 8 Zones � a set time (Window) within which ALL the Zones in the respective Group must detect violation. From Standby status, each Group will operate as fol- lows: violation of any of the Zones in the Group will not generate an Alarm but will start the programmed Win- dow. If ALL the Zones in a specific Group detect violation within the programmed window, the system will gener- ate the respective Zone Alarms, and will indicate the Zones concerned on the Keypad. If NOT ALL the Zones in the Group detect violation 42 Figure 29 AND Zones Page

within the programmed Window, the system will refresh

the window and restore to Standby. After generating a Zone Group Alarm, the system will be unable to generate further Alarm cycles until ALL the AND Zones concerned restore to Standby. ‘Reset Partition Alarm’, ‘Arm/Disarm Partition’ or ‘Stop Partition Alarm’ operations will restore ALL the AND Zones of the Partition concerned to standby. The Zones of a Group need not have Partitions in com- mon. AND Zones can be set up via PC only. Wireless Systems with VectorRX Receivers can manage up to 32 Wireless Zones and up to 16 Wireless keys. A Installation of a VectorRX Receiver will downgrade the IMQ SECURITY SYSTEM Approval from Grade II to Grade I. The IMQ SECURITY SYSTEM Approval applies only when no more than 14 Wireless keys are used. The Wireless Zones support the following Detectors: � AMD10 - Wireless Pet-immune Infrared Detector � AMC10 - Wireless Magnetic Contact � AGB10 - Wireless Glass Break Detector � ASD10 - Wireless Optical Smoke Detector � Wireless Devices other than those listed above are not supported by the VectorRX Receiver. Read the “APPENDIX” for further information on the listed Devices. The system can detect Alarm, Tamper, Low Battery and Lost Wireless Detectors. When a Wireless Detector (assigned to a Wireless Zone) detects Alarm conditions, the system will gener- ate the respective Alarm on zone no. - Wireless event, and other events which depend on the programmed “Type” (refer to “Type” under “Hardwired Zones”). When a Wireless Detector (assigned to a Wireless Zone) detects Tamper conditions, the system will gen- erate the respective Tamper on zone no. - Wireless event, and other events which depend on the pro- grammed “Type” (refer to “Type” under “Hardwired Zones”). When the battery of a Wireless Detector (assigned to a Wireless Zone) is Low, the system will generate a Warning low battery on wireless device event . This event will not identify the Wireless detector in question. However, the relevant information will be recorded in the logger as follows: � TYPE - Low Battery � ID. EVENT - Description of the Wireless Zone no. When a Wireless Detector fails to transmit, the system will generate aLost wireless zone event. The Wireless detec- tor in question will not be identified. However, the relevant information will be recorded in the logger as follows: � TYPE - Wireless Device Disapp. � ID. EVENT - Description of the Wireless Zone Wireless keys can Arm in Stay/Away mode and Disarm the Partitions they are assigned to. Wireless keys have an auxiliary button that can gener- ate the following events: � Key F on KeyFob P1 � Key F on KeyFob P2 � Key A on KeyFob P1 � Key A on KeyFob P2 � Key P on KeyFob P1 � Key P on KeyFob P2 The Wireless page will allow you to program the Wire- less Zone and Key parameters, as follows. KYO 300-KYO100 PROGRAMMING 43 Figure 30 Wireless Page

The list on the left side of the page shows the Wireless

Zones and Keys of the system. The following informa- tion is shown for each Wireless Zone and Key. � If the Wireless Device Receiver option is Disabled (refer to the Accessories page), the left side of the Wireless page will be empty. No. This field shows the Wireless Zone or Key ID num- ber which will be used in some parts of the application instead of the Wireless Zone or Key Description. Position This field shows the Description of the hard- ware device the Wireless Zone or Key is assigned to. Description This editable field (16 characters) is for the Wireless Zone or Key label (e.g. the detector place- ment or the name of the Key User). This Description will identify the Wireless Detector or Key in all the oper- ations it is involved in. The right side of the page will allow you to program the parameters of the Wireless Device (to be selected on the left), as follows. � The right side of the page shows the various pa- rameters for the Wireless Zones or Keys. Serial Number This editable field is for the ESN (Elec- tronic Serial Number) of the Wireless detector which is assigned to the selected Wireless Zone. � You cannot program the device parameters until you have entered its ESN. The ESN will allow the Control panel to identify the wire- less device on the system. The ESN may comprise hexadecimal digits (A, B, C, D, E and F), in order to lower the risk of duplicate ESNs. � Some Wireless Devices have 5-digit and 6-digit ESNs (printed on back), use ONLY 6-digit ESNs with this Control panel. Supervised If this option is Enabled, the system will be able to signal the loss of the Wireless detector. The Re- ceiver will trigger the Lost wireless zone event as soon as the programmed Supervisory time expires (refer to the Time supervision zones under “Accessories” in the “Configuration” section). The placement of Wireless detector will not be indicated, however, the relevant in- formation will be recorded in the logger. A The IMQ SECURITY SYSTEM Approval applies only when the Supervised option is Enabled for ALL the Wireless zones, and the Time Supervision Zones interval is set at 2 hours 30 minutes (refer to “Accessories” in the “Configuration” section). Type Refer to “Type” under “BPI Zones”. Voice Messages Refer to “Voice messages” under “Wired Zones”. Attributes Refer to “Attributes” under “Hardwired Zones”. Cycles Refer to “Cycles” under “Hardwired Zones”. Partitions Refer to “Partitions” under “Hardwired Zones”. Full Arming Alarm Refer to “Full Arming Alarm” under “Hardwired Zones”. Inactivity Refer to “Inactivity” under “Hardwired Zones”. � The Inactivity Timeof Wireless Zones must not be less that 5 minutes. � Replacing Wireless Devices To replace a Wireless detector (assigned to a Wireless Zone): select the required Wireless Zone, then enter the ESN of the new Wireless detector in the Serial Number field. To replace Wireless Key: select the required Wireless key, then enter the ESN of the new Wireless Key in the Serial Number field. � Enrolling Wireless Devices To enrol a Wireless detector: select an empty Wireless Zone, then enter the Wireless detector ESN in the Se- rial Number field. To enrol a Wireless Key: select an empty key place- ment (ESN = 0) then enter the Wireless Key ESN in the Serial Number field. � Unenrolling Wireless Devices To unenrol a Wireless detector (assigned to a Wireless Zone): select the required Wireless Zone then enter 000000 in the Serial Number field. To unenrol a Wireless Key: select the required Wireless Key then enter 000000 in the Serial Number field. Outputs Control panel Outputs no. 1, no. 2 and no. 3 (no. 1 and no.2forKYO100)are 3 A double switching relays. The ter- minals for these Outputs are: � Output no. 1 = +N1, +A1, C1-NC1-NA1 � Output no. 2 = +N2, +A2, C2-NC2-NA2 � Output no. 3 = +N3, +A3, C3-NC3-NA3(KYO 300 only) A In order to comply with: CEI EN 60 950:2001 — de- vices controlled by Relay Outputs no. 1, no. 2 and no 3 must have SELV circuits. The Control panel Outputs no. 4, no. 5 and no.6 (no.3 and no. 4 for KYO 100) are 1 A Open-Collectors. The terminals for these Outputs are: OC1, OC2 and OC3. 44

The Expander Outputs are 0.15 A Open-Collectors.

The terminals for these Outputs are OC1, OC2, OC3, OC4, OC5 and OC6. A The IMQ SECURITY SYSTEM Approval applies only when the Expander Open-Collector Outputs are interfaced with relays (installed inside the Ex- pander boxes). The Output Expander Buzzer 98 can be connected to the terminal [OC6] via jumper 99: � 1 ooo 3 = buzzer OFF (at default): � 1 //o 3 = the buzzer will sound when the terminal [OC6] opens; � 1 o// 3 = the buzzer will sound when the terminal [OC6] closes to Negative. The Control Panel Outputs and Expander Outputs can be associated with Events that activate signalling de- vices (Sirens, Flashers, etc.), or used to provide Oper- ating/Trouble status and device control signals. They can also be used to turn ON/OFF electrical appliances at the Keypad or via telephone (Heating, Garden sprin- klers, etc.). The Outputs page will allow you to program the Control Panel and Expander Output parameters, as follows. The table on the left side of the Outputs page shows the Outputs. The number of available Outputs depends on the system (refer to “Configuration”). The following information will be shown for each Output. No. This field shows the Output ID number, used in some parts of the application, instead of the Output De- scription (refer to “Description”). Position This field shows the Description of the Out- put placement. This label can be edited on the Output Expanders page. Device This field shows the Address of the Output place- ment (Control Panel Outputs are indicated by a hyphen). Ter. This field shows the Output terminal tag: � RL1 = +N1, +A1, C1-NC1-NA1 � RL2 = +N2, +A2, C2-NC2-NA2 � RL3 = +N3, +A3, C3-NC3-NA3 Description This editable field (16 characters) is for the Output label (e.g. the detector placement or the name of the Key User). The Parameters on the right side of the Outputs page can be programmed as follows. Type The Output can be programmed as either Mono- stable (M) or Bistable (B). Pol. The Output can be programmed as either Normally Closed (NC) or Normally Open (NO). � Type Bistable This type of Output will activate when AT LEAST ONE of its associated Events occurs, and will stop when ALL of its associated Events end. A The IMQ SECURITY SYSTEM Approval applies only when the Outputs — used for Alarm device activation — are MONOSTABLE. Monostable ThistypeofOutputwillactivatewhenATLEAST ONEofitsassociatedEventsoccurs,andwillstopwhenthepro- grammed ON Time expires (see “ON Time” below). � Polarity This programming field will allow you to program the Output standby polarity . Normally Open The electrical state during standby is: [+N] terminals open; Positive signal (13.8V) on the [+A] terminals; [C] terminals closed to their respective [NO] terminals; [NC] and [OC] terminals open. KYO 300-KYO100 PROGRAMMING 45 Figure 31 Outputs page

Normally Closed The electrical state during standby

is: Positive signal (13.8V) on the [+N] terminals; [+A] terminals open; [C] terminals closed to their respective terminals [NC]; [NO] terminals open; [OC] terminals closed to Negative. � Attributes Reserved This Attribute will allow the User to acti- vate/stop the Output from the Keypad or via telephone (refer to “Activating Outputs” under “KEYPAD OPERATIONS" in the PROGRAMMING FROM KEYPAD MANUAL, and to the “OPERATIONS VIA TELEPHONE” section in the USER MANUAL). � Reserved Outputs CANNOT be associated with the Events on the Events-Actions page. � When you exit a programming session via PC, Mo- dem or Keypad, the Reserved Outputs will restore to the status they were in before the programming session started. Output followed This field will allow you to associate the selected Output with another Output. The selected Output will track the specified Output (i.e. be activated by the same Events, and perform the same Actions). If you DO NOT want the selected Output to track an- other Output, you must select “None” in this field. An Output that is programmed to track another Output will: � activate when the specified Output activates; � restore to standby when the “tow” Output restores to standby. � If you program an Output to track another Output, you will not be able to associate it with the Events on the Events-Actions page. Supervised If the system has been duly set up, this At- tribute will allow the system to monitor the Output for short circuits and interrupted connections (refer to NOTE). � This Attribute can be selected for Outputs no. 1, 2 and 3 (for KYO 300 only). NOTE: Terminal [+A] must be wired in accordance with the instructions in the “Supervised Outputs” paragraph (refer to the “INSTALLATION” section under “Con- necting Signalling Devices”), otherwise, the system will be unable to signal short circuits and interrupted connec- tions on the Supervised Outputs. � Associated Timer This section will allow you to associate a Timer with the Output. The Output can be activated ONLY by the se- lected Timer (refer to “Time Programmer - Timer”). � When the Timer window expires, the Output will re- store to standby, even if the conditions that gener- ated the event are still present. A The IMQ-SECURITY SYSTEM Approval applies only when the Outputs, set up to signal Burglary, Tamper and Duress ARE NOT associated with Timers. � Times This section will allow you to set the On/Off Times of the Output. � The ON Time and OFF Time can be set for Mono- stable Outputs only. 46 ... on set ... end EVENT ... onset ... on standby OUTPUT Bistable ... onset ... on standby OUTPUT Monostable Half cycle ON time OFF time 1st Cycle 2nd Cycle the event ends here if it is associated with a Monostable Output Figure 32 The Effect of the Oscillation and Cycle parameters on Bistable and Monostable Outputs

ON Time This is the maximum activation time of the

Output. Valid entries: � 0.2 through 25.4 seconds, in 0.2-second steps (for sec. option) � 1 through 127 minutes, in 1-minute steps (for Min. option) Default setting: 3 minutes OFF Time This is the minimum OFF Time after restoral of the Output. The Output will be unable to re-activate until the programmed OFF Time expires. Valid entries: 1 through 255 seconds, in 1-second steps. Default setting: 3 minutes � Oscillation Outputs with this attribute will remain active for the pro- grammed time, return to standby for the same amount of time, and then reactivate. Oscillating Outputs can be used to generate visual and audible signals (cause LEDs to blink or buzzers to sound). Oscillation parameters Half Cycle This field will allow you to program the amount of time the Output will be active, and the amount of time it will be in standby status during Oscillation. Valid entries: 200 msec (milliseconds) through 1400 msec in 200 msec steps; If you set 0, the Output will not oscillate. � Cycles Monostable Outputs may continue to run the pro- grammed number of Cycles even after the triggering event has been cleared. During each cycle, the Output will be active for the pro- grammed ON Time and will restore to standby for the programmed OFF Time. If a Half Cycle has been pro- grammed, the Output will oscillate in accordance with the Half Cycle parameters (during the ON Time). This field will allow you to set the number of Output Cycles, as follows. � The parameters in the Cycles section can be set for Monostable Outputs only. Cycles This field will allow you to set the number of cy- cles the Output must run. Valid entries: 1 to 31 Cycles (1 Cycle is set at default). Timeless If this option is enabled, the Output will run an unlimited number of cycles. In which case, the Out- put cycles can be interrupted ONLY by Partition Reset or Control Panel Reset. ! DO NOT associate Outputs with the Timeless attribute with NON Restorable-NON Spot, Spot and Special events, as these events cannot be stopped. � Events The Events button will allow you to view the Events that activate the selected Output. Partitions Each Partition consists of a group of zones that the sys- tem manages independently (Virtual Control Panel). Each Partition can be programmed with its own Codes, Timers, Actions and Parameters. This system manages 32 Partitions. You can setup the Partitions in the BPI Zones and Wireless pages. The layout of the Partitions page is as follows. No. This field shows the Partition ID number, used in some parts of the application instead of the Description (e.g. for Telephone Access). KYO 300-KYO100 PROGRAMMING 47 Figure 33 Partitions page

Description This field is for the Partition Label (16

characters). The Description will identify the Partition in all the operations it is involved in. Entry Time This field will allow you to set the Partition Entry Time. Violation of an Armed Entry Delay Zone will trigger the programmed Entry Time. The Partition Entry Time will be signalled by: � the Entry time on partition event for the Partition; � an audible signal from the Partition Keypads. An Alarm will not be generated if the violated Partition is Disarmed before the Entry time expires. Exit Time This field will allow you to set the Partition Exit Time. Violation of an Armed Exit Delay Zone will trigger the programmed Exit Time. If violation ends before the Exit time expires, the Zone will not generate an Alarm. The Partition Exit Time will be signalled by: � the Exit time on partition event for the relevant Par- tition; � an audible signal on the Partition Keypads. Last Exit Time This field will allow you to set the Last Exit Time. Violation of an Armed Last Exit Zone will trigger the programmed Last Exit Time of its Partition. This feature will allow the system to Arm as soon as the programmed Last Exit Time expires. Valid entries for Entry, Exit and Last Exit Times: 0 minutes and 0 seconds through 59 minutes and 55 seconds, in 5-second steps. If you enter a higher value, it will be converted automati- cally to the maximum admissible value. If you enter a value that is not a multiple of 5 seconds, it will be rounded off to the nearest 5-second step. Default setting: 1 minute. Partition Code This field is for the Partition User Code. When a Partition-related event occurs, the Digital Communicator will send the relevant Partition Code to the telephone numbers with the Send Always option Disabled (refer to “Digital Communicator”). The Partition Code is useful in shared Security system applications (for example, in an apartment building or Shopping Mall, etc.) where it is necessary to identify the Partition in Alarm status rather than the system (the Partition Code will identify the Partition whereas the Customer Code will identify the system). � If the reporting format supports 4 digits, only the first four digits will be sent. If the protocol does not support hexadecimal digits (A, B, C, D and F), they will be converted to 0. Negligence Time Under normal circumstances, Users Arm their systems with a certain regularity, if this does not occur, it may be due to Negligence on the User’s be- half or may mean that the User is in difficulty (due to se- rious illness, accident or delinquency), in which case, this feature will prompt the Central station operator to take the necessary action. This programming field will allow you to set the Negli- gence Time. If the system is not Armed within the pro- grammed time, the Control panel will generate the Neg- ligence on Partition event. Valid entries: 1 through 60000 minutes (41 days and 16 hours) in 1-minute steps. Invalid entries (over 60000 minutes) will generate an er- ror message. If this option is left at default (0), Negligence will not be signalled. Negligence will be signalled by: � the Event negligence on partition event — rele- vant to the Partitions the Zone is assigned to. Auto-Arm Timeout This field will allow you to program the Automatic Arm pre-alert period. For example, if the Timer is set to Arm Partition no. 1 at 17:45 p.m. with a 15-minute Auto-Arm Timeout, the system will generate the Autoarming warning parti- tion no. 1 event at 17.30, and will signal the start of the pre-alert period. The pre-alert signal will warn anyone on the premises that the system is about to Arm. During the pre-alert phase the system will accept Overtime Requests. If no valid Code is entered during this period, the sys- tem will Arm as programmed. The event will end when the programmed Auto-Arm Timeout expires or when the Partition Arms after an Overtime request. Valid entries: 0 through 240 minutes, in 1-minute steps. If you set 0, there will be no warning. If you enter a higher value than the maximum, it will be converted automatically to 240 minutes. Auto-Arm Signal If this option is enabled (�) for the Partition (Enabled at Default), the Partition Keypads will emit an audible signal (beep) during the entire pre-alert period. Extended Ready-to-Arm Delay When a Partition trig- gers an Alarm, the system will generate the relevant Memory alarm on partition event which, as a result, will generate the Extended not Ready-to-Arm parti- tion event (refer to “Extended not Ready-to-Arm parti- tion” under “Events-Actions”). The Extended Ready-to-Arm Delay determines the period between the start of the Partition Alarm and forced termination of the Extended not Ready-to-Arm partition event. Valid entries: 0 through 30 minutes, in 1-minute steps. If you enter a higher value than the maximum, the appli- cation will prompt the maximum setting of 30 minutes. Default setting: 5 minutes. Patrol Time This programming field will allow you to set the Patrol Time. If the system is disarmed by a User Code with the Patrol attribute (refer to “Patrol Code” un- der “Keypad Codes — User”), it will rearm automatically when the programmed Patrol Time expires. Valid entries: 0 through 254 minutes in 1-minute steps Default setting: 10 minutes. 48

Autoreset on Arming If this option is enabled (at de-

fault), the system will Reset Partition Alarms each time it is Armed (refer to “Reset Partition Alarms” under “Keypad Codes — Code Types”). Timer Associated Arming This option provides the system with an Arm command filter. If a Timer is associ- ated with the Partition, the system will execute com- mands to Arm the Partition ONLY when the Timer is ‘ACTIVE’ and the programmed ‘ON Time’ is running (refer to “Scheduler - Timers”). Commands to Arm the Partition during the programmed ‘OFF Time’ will be de- nied. Timer associated Disarming This option provides the system with a Disarm command filter. If a Timer is associated with the Partition, the system will execute commands to Disarm the Partition ONLY when the Timer is ‘ACTIVE’ and the respective ‘ON Time’ is run- ning (refer to “Scheduler - Timers”). Commands to Dis- arm the Partition during the respective ‘OFF Time’ will be denied. Telephone The Telephone page will allow you to program: � the Telephone numbers for the Digital Communica- tor, Dialler, Auxiliary Communicator and Teleservice facilities; � Telephone line parameters; � the Answering Machine parameters. The layout of the Telephone page is as follows. No. This field shows the Telephone ID number. This number will be used instead of the Description (User la- bel) in some parts of the application. Telephone Number This editable field (maximum 20 digits) is for the Telephone number the system will call. Valid entries: digits from 0 to 9, pound (#), star (*) and comma (,). The comma can be used to insert pauses, for example, between a switchboard number and a telephone number. Description This editable field (maximum 16 charac- ters) is for the Telephone Number label (e.g. User Name). The Description at default is [Tel. Number nnn] — (nnn represents the ID number of the Telephone Number). Used by This programming section will allow you to assign the Telephone facilities: � Dial. = Dialler � Dig. = Digital Communicator � Tel. = Teleservice � Answer The Answer section will allow you to program the Con- trol Panel answer mode. � The Control Panel cannot answer incoming calls when the Answering Machine or Teleservice facil- ity is Disabled (refer to “Enable/Disable Teleservice” and “Enable/Disable Answering Ma- chine” in the USER’S MANUAL). Rings This field will allow you to program the number of rings the Control panel must allow before answering an incoming call. � If the Double call option is enabled, the number of Rings will be ignored (refer to “Double call” under “Teleservice”). � Dialling The Dialling section will allow you to program the Con- trol Panel Dialling mode. Line Check If this option is Enabled, the system will supervise the telephone line. The system will signal “Line down” (i.e. voltage on the [L.E.] terminals less than 3V for over 45 seconds) by: KYO 300-KYO100 PROGRAMMING 49 Figure 34 Telephone page

� turning ON the G9 LED;

� generating the Line Trouble signal — an X (blinking) above the i icon; � generating the Telephone line trouble event. The system will signal “Line restoral” (voltage on the [L.E.] terminals more than 3V for 15 seconds) by: � turning OFF the G LED (i.e. unless there are other faults); � clearing the Trouble signal; � terminating the Telephone line trouble event. This option must be Disabled when the Control Panel is not connected to a telephone line, otherwise, the Tele- phone line trouble event will be signalled persistently. Start Telephone Call Delay This field will allow you to program a delay between the start of the Alarm and the first outgoing Alarm call. This delay will give the User time to verify the Alarm and stop outgoing calls in the event of false Alarm. � The Start Telephone Call Delay will be applied to the first Telephone number in the Call Queue. Valid entries: 0 through 1200 seconds (20 minutes), in 1-second steps. Default setting: 0 seconds. Tone Check If this option is enabled, the Control panel will check for the dialling tone before dialling. If the dial- ling tone is not detected within the programmed Time- out for Dial the Control panel will hang-up and retry. Pulse Dial This Control Panel has been set up to dial in DTMF (Touch-tone). If this option is enabled, the Control Panel will dial in Pulse. Tones This option will allow you to select the country. The selected country will allow the Control panel to op- erate properly on the local terrestrial line. � If the country is not listed, select EUROPEAN GENERIC. � If the Control panel is unable to operate properly using EUROPEAN GENERIC, you must Disable the Tone check. � Answering Machine The Answering Machine function will allow you to re- cord a Voice Answer Message. The message will be played each time the Control Panel answers a call after the programmed number of Rings. � The Answering Machine function can be En- abled/Disabled by the User (refer to “Enable/Dis- able Answering Machine” in the USER’S MANUAL). If the Teleservice facility is also Enabled, the Control Panel will emit a beep, wait approximately 6 seconds for the Modem to respond (if connected) and, if no re- sponse is detected, will play the Message. If the An- swering Machine Message has not been recorded the Control panel will emit a beep. The layout of the Answering Machine window is as fol- lows. Answer Message This field will allow you to select the Answering Machine Voice Message (refer to “Voice Messages”). Message Repetitions This field will allow you to pro- gram the number of times the message must be played. Valid entries: 0 through 255; Default setting: 3. Replay Pause This field will allow you to program a pause between Answer Message announcements. Valid entries: 1 through 254, in 1-second steps; Default setting: 5 seconds. PIN Timeout This field will allow you to program the time the User will have to enter the User Code (with re- mote Telephone Access) on the telephone keypad. Valid entries: 1 through 254 seconds, in 1-second steps Default setting: 30 seconds. � Only Codes no. 132 to 195 can access the Control Panel via telephone (refer to the “Codes” para- graph). DTMF Tone Timeout This field will allow you to pro- gram the time (in seconds) the User will have to enter the Command after Code acceptance. If no telephone key is pressed within the programmed time, the Control Panel will end the call. Valid entries: 1 through 254 seconds, in 1 second steps. Default setting: 30 seconds. Dialler The Dialler page will allow you to define up to 50 Ac- tions. Each Action can be associated with one or more Events in the Events-Actions page. The Actions will 50 Figure 35 Answering Machine window 9 The G LED signals several different types of Trouble events. If the signal is due to telephone line trouble, the Keypad (in View Trouble Mode) will show the Tel.Lin.Failure message.

signal via Telephone the start and/or end of their asso-

ciated Events. Each Dialler Action can send a Voice Message to a maximum of 32 Telephone numbers. Message Queue The Dialler will not end the call until all the messages destined for the connected telephone number have been sent. This feature reduces call time and costs. � Events will not be queued when the Call success- ful number option is Enabled (refer to “Options” under “Dialler”). The layout of the Dialler page is as follows. � The Dialler parameters apply to all the numbers in the Dialler book. � Dialler book The Dialler book will allow you to assign up to 32 Tele- phone numbers from the General book (refer to “Tele- phone”) to the Dialler Facility. No. This is the Identifier number (1 through 32) which represents the Telephone number in the Actions win- dow. This Identifier number DOES NOT CORRESPOND to the Telephone Number ID number in the General Phonebook. Telephone Number This field will allow you to select the Telephone Number the Dialler must call. 1. Click on the field you wish to program. 2. Click again on the same field: the program will dis- play the Telephone Numbers in the General Phonebook. 3. Select the required Telephone Number. � The ID numbers can be entered in any order. How- ever, the sequence defined in the Dialler phonebook will determine the call priority. � Send Message after ... This section will allow you to program when the Voice Message announcement. Voice on line If this option is enabled, the Voice mes- sage will be played after detection of a voice response. If the Control Panel does not detect a voice response within the programmed Voice timeout, it will hang-up and generate a Dialler action failed event. Dial If this option is enabled, the Voice message will be played after Dialling. Time out If this option is enabled, the Voice message will be played when the programmed Delay after dial- ling expires. � All calls that comply with the programmed Send Message After conditions will be considered Suc- cessful. However, only the Voice on Line option ensures a proper response to calls, therefore, if you select Dial orTimeout, you should also enable Confirm successful calls option. Voice Timeout This field will allow you to program a pause after dialling. If the Control Panel does not detect a voice answer within the programmed Voice timeout, it will hang-up and generate a Dialler action failed event. � The Voice Timeout applies to the Voice on Line option (under Send Message After ...). Valid entries: 1 through 255 seconds, in 1-second steps Default setting: 15 seconds Delay This field will allow you to program a pause be- tween the end of dialling and the Voice Message an- nouncement. KYO 300-KYO100 PROGRAMMING 51 Figure 36 Dialler page

� The Delay applies to the Timeout option (under

Send Message After ...). Valid entries: 1 through 255 seconds, in 1-second steps Default settings: 5 seconds � Messages The Messages section will allow you to program some of the Voice Message parameters. Message repetitions This field will allow you to pro- gram the number of times the Control Panel must re- peat the Voice Message. Valid entries: 1 through 99 Default setting: 3 Replay Pause This field will allow you to program the pause (in seconds) between Voice Message an- nouncements. Valid entries: 1 through 10 seconds, in 1-second steps Default setting: 1 second � Options The Options section will allow you to program some of the Dialler options. Call successful numbers If this option is enabled, the Telephone numbers of successful calls WILL BE REDIALLED in subsequent call cycles. If this option is disabled (at default), the Telephone numbers of suc- cessful calls WILL NOT BE REDIALLED in subsequent call cycles. � Events WILL NOT be queued when the Call suc- cessful numbers option is enabled (refer to “Events Queue” under “Digital Communicator”). Confirm successful calls If this option is enabled, the Control Panel will not consider a call successful until the call receiver presses the star key on the telephone keypad, in order to generate a feedback signal. � If this option is enabled, you should include a re- quest for the feed back signal (press star) in the message. Attempts This field will allow you to program the maxi- mum number of call attempts the Dialler will make be- fore aborting the call. Valid entries: 1 through 99 Default setting: 5 � Actions Each Dialler Action will trigger a series of telephone calls (Voice Messages). The Actions button opens the Actions window, the layout of which is as follows. No. This field shows the Action identifier number. This number is to be used on the Events-Actions page, to associate the Action with the Events. ! If you select this field, the Action will take absolute Pri- ority over all other Actions. Therefore, if one of its asso- ciated Events occurs, the Control Panel will suspend any ongoing Dialler calls, and will call the telephone numbers of the Priority Action. To assign Priority (!): double click on the corresponding cell. � Only one Dialler Action can take priority. 1 ... 32 Numbers 1 through 32 represent the Dialler Telephone Numbers (refer to the No. column in the Dialler book on the Dialler page). To assign an Action to a Dialler Telephone Number, double click on the corresponding cell (Y indicates that the Action will generate a call to the corresponding Dial- ler Telephone Number. � Each time you click on a Telephone Number cell (1 through 32), the application will display the com- plete Telephone Number and corresponding De- scription (User Label). 52 Figure 37 Dialler settings window

All If this option is enabled, the Control Panel will call

all the Telephone numbers for the corresponding Ac- tion. If this option is disabled (at default). The Dialler will call associated Telephone numbers until one call is suc- cessful. To enable (Y) this option, press ENTER or dou- ble click on the relevant cell. Message 1-2-3-4-5 This option will allow you to setup the Voice Messages (refer to “Voice Messages” and “Preset Messages” for further information). Description This editable field is for the Action label. Hide This button will allow you to hide the Telephone number columns (1 through 32), and Voice Message columns (Messages 1 through 5). Events This button will allow you to view all the Events that generate the selected Action. Digital Communicator The Digital Communicator will allow you to define up to 100 Actions. Each Action can be associated with one or more Events in the Events-Actions page, and will sig- nal (via telephone to Central Stations, etc.), the start and/or end of its associated Events. Each Digital Communicator Action can transmit two dif- ferent event codes to two distinct groups (8 Telephone numbers per group). Thus it will be possible to transmit the same event in two different Reporting formats (e.g. a Trouble signal to the Installer and Central Station). Event Queue The Digital Communicator will not end the communication until all the events destined for the connected service have been transmitted. This feature reduces communication time, and call costs. � Events will not be queued for Telephone numbers which are associated with Reporting formats with the Voice feature. The layout of the Digital Communicator page is as fol- lows. no. This ID number (1 through 8), corresponds to the Telephone number Identifier in the Actions window. This Identifier number DOES NOT CORRESPOND to the Telephone Identifier number in the General Phonebook. Telephone Number to call This field will allow you to select the Telephone Num- bers for the Digital Communicator (from the General Phonebook on the Telephone page). Protocol This field will allow you to select the Re- porting format. This Control Panel supports the Reporting formats shown Table 4. (refer to “Communication Protocols” in the APPENDIX). The first five protocols are also available with the Voice feature. � Both the Control panel and Central Station must be able to manage voice communications, otherwise, Reporting formats with the Voice feature cannot be used. Once the digital transmission has been completed, the Control Panel will open the Voice channel, and the Central Station operator will be able to open a Talk/lis- ten session. The system Users will be able to communicate with the Central Station operator via the VOX-REM Microphone and Speaker boards (refer to “K3-VOX Voice Cards” in the “APPENDIX”). The Voice channel will remain open for the pro- grammed time (refer to “2-way audio”), or until the Cen- tral Station operator ends the session. KYO 300-KYO100 PROGRAMMING 53 Figure 38 Digital Communicator page

� Reporting formats with the Voice feature transmit

ONLY one event per call. Reporting formats with the Voicefeature should only be used when absolutely necessary. For events that do not require the Voice channel feature, use the same Re- porting format without the Voice feature, as follows: 1. Select the same Telephone number (Central Sta- tion number) in two programming fields on the Digi- tal Communicator page. 2. Select the Reporting format “without Voice” in one programming field, and the same Reporting format ”with Voice” in the other. 3. In the Digital Communicator Actions window: for events that DO NOT REQUIRE a Voice channel — select the Central Station that supports the Re- porting format “without Voice”; for events that REQUIRE a Voice channel — select the Central Station that supports the Re- porting format “with Voice”. System Code This field is for the System ID Code (usually assigned by the Central Station). The System Code format (number of digits and valid range) de- pends on the selected Reporting Format (refer to the CUSTOMER CODE column in the Table 4). Send Always If this option is Disabled, the Digital Communicator will transmit the Partition Code when the Action is triggered by a Partition-related event, and will transmit the System Code when the Action is trig- gered by any other type of event. If this option is Enabled, the Digital Communicator will transmit the System Code regardless of the type of event. Attempts This field will allow you to program the maxi- mum number of Call attempts for each Telephone Num- ber. Valid entries: 1 through 99 Default setting: 3 2-way audio This option will allow you to program the 2-way audio session time. Valid entries: 0 through 180 seconds (3 minutes), in 1-second steps. Default setting: 30 seconds � Actions The Actions button opens the Actions window. Each Digital Communicator Action comprises two sub-actions, each of which sends a Code Call to a se- ries of telephone numbers. No. This field shows the Action ID number. This num- ber is to be used on the Events-Actions page to asso- ciate the Action with the Events. ! If this option is enabled, the Action will take absolute Priority over all other Actions. Therefore, if one of its as- sociated Events occurs, the Control Panel will suspend any ongoing Digital Communicator calls, and will call the telephone numbers of the Priority Action. To assign Priority (!): double click on the corresponding cell. � Only one Digital Communicator Action can have priority. Code This field is for the Event Code. The Event Code format depends on the selected Reporting Format (re- fer to the EVENT CODE column in the Table 4). The preset Event Codes of TELIM and SIA Reporting Formats CANNOT be edited (refer to “Reporting For- mats” in the “APPENDIX”). Therefore, the Communica- tor will transmit the preset Event Code. ThepresetEventCodesofCONTACTID canbeedited(refer to “Reporting Formats” in the “APPENDIX”). If the cell is left empty, the Communicator will transmit the preset Event Code, otherwise, it will transmit the edited Event Code. 54 REPORTING FORMAT TYPE CUSTOMER CODE digits (validity) EVENT CODE digits (validity) NOTES ADEMCO/SILENT KNIGHT - Slow 10 baud Pulse 3/4 (0 ÷ F) ½ (0 ÷ F) 0 = A ADEMCO/SILENT KNIGHT - Fast 20 baud Pulse FRANKLIN/SESCOA/DCI/VERTEX - Fast 20 baud Pulse RADIONICS - 40 baud Pulse SCANTRONIC - 10 baud Pulse CONTACT ID DTMF 4 (0 ÷ F) Pre-set (0 ÷ F) 0 = A TELEMAX Pulse 3 (0 ÷ 9) 1 (0 ÷ 9) DIGIFON FOR FUTURE USE! TELIM Pulse 6 (0 ÷ 9) Pre-set CESA FSK 5 (0 ÷ 9) 2 (0 ÷ 9) SIA FSK 4 (0 ÷ 9) Pre-set Table 4 Digital Communicator Reporting Formats

� Contact ID Event Codes must comprise 2 digits. If

you enter one digit only, the application will auto- matically add the letter A ( e.g. 1 will be changed to A1). 1 ... 8 These Numbers represent the Digital Communi- cator Telephone Numbers that will be called when the Action occurs. The Digital Communicator Numbers are represented by their ID Number (see No. column on the Digital Commu- nicator page). To select/deselect a Digital Communicator Number, double click on the relevant cell (YES indicates that the Digital Communicator Number will be called). � If you associate an Action with a Digital Communicator Number which transmits in CONTACT ID, TELIM, CESA or SIA Reporting Format, any other Digital Communicator Numbers, assigned to the Action in question, must transmit in the same Reporting Format. All If this option is Enabled, the Control Panel will call all the numbers when the corresponding Action occurs. If this option is Disabled (at default), the Control Panel will terminate the call cycle after the first successful call. To enable (Y) this option, press ENTER or double click on the relevant cell. Description This editable field is for the Action label. Events This button will allow you to select the Events that will trigger the Action. CONTACT ID If the selected telephone number is as- sociated with CONTACT ID, it is possible to associate this reporting format automatically to priority events, by selecting and confirming CONTACT ID (see the Figure below). Auxiliary Communicator (KYO 300 only) This Control panel can manage a K3-AuxCom Auxil- iary Communicator (accessory item). If the Control panel blocks, this backup device will takeover the com- munication transmissions (refer to “Auxiliary Communi- cator K3-AuxCom” in the “APPENDIX”). The Auxiliary Communicator can send a different Cus- tomer Code and Event Code to up to 8 Telephone Num- bers. The layout of the Auxiliary Communicator page is as follows. � The Auxiliary Communicator parameters cannot be programmed until The Auxiliary Communica- tor Present option (Accessories page) has been Enabled. Telephone Number to call Enter the required Tele- phone number (maximum 20 characters). Valid entries: digits 0 through 9, pound (#), star (*) and comma (,). Use the comma for dialling pauses (e.g. between a switchboard number and telephone number). Protocol This field will allow you to select the Central Station Reporting Format (refer to “Protocol” under “Digital Communicator”). Customer Code This field is for the Control panel ID Code — assigned by the Central Station (refer to “Sys- tem Code” under “Digital Communicator”). Event code This field is for the Control panel “Blocked” Code — assigned by the Central Station (refer to “Codes” under “Digital Communicator). Call successful numbers If this option is enabled, the Auxiliary Communicator will dial all the programmed telephone numbers. If this option is Disabled (at de- fault), the Control Panel will terminate the call cycle af- ter the first successful call. Voice Messages This function is provided by the K3-VOX Voice Board (ac- cessory item). TheK3-VOX will allow the Control Panel to manage up to 62 Voice Messages with programmable quality and length. The amount of message time available depends on the sound quality of the messages, and KYO 300-KYO100 PROGRAMMING 55 Figure 39 Digital Communicator window

ranges from 2 minutes 8 seconds for high sound quality,

to 8 minutes 33 seconds for low sound quality (refer to “K3-VOX Voice board” in the “APPENDIX”). � Message No. 61 can be used for the Memo facility (refer to “Memo” in the USER’S MANUAL) and Message No. 62 for the Continuous Recording fa- cility (refer to “Enable Continuous Recording” un- der “Options”). If the Home Memo and/or Continuous Recording facilities are not used, these messages can be used for other purposes. The Voice messages can be used for the: � Zone status control � Answering Machine message � Dialler messages � Memo facility � Continuous Recording facility � Voice Messages can be recorded and played at the Keypad, as described in the KEYPAD PROGRAMMING MANUAL. The layout of the Voice Messages page is as follows. No. This is the non-editable Message ID Number. This number substitutes the Message Description in some parts of the application. Description This editable field is for the Message label (maximum 16 characters). Quality This field will allow you to select the sound qual- ity, as follows: click the required cell; click again to highlight the program- ming field; click the arrow to open the drop-down menu. Time Enter the Message length (in seconds). Leftover Time This field will show the residual time which can be added to other Voice Messages. The residual time depends on the selected quality. With quality Select the Voice Message quality. � Compound Messages The Control panel Dialler can manage Compound Mes- sages. This type of Message takes up less time than a regular Message. Therefore, if you must record several messages with parts in common, such as an Address, the Compound Message will allow you to save mes- sage time. For example, instead of recording: � Message 1 (regular Message taking 5 seconds) <> � Message 2 (regular Message taking 5 seconds) <> � Message 3 (regular Message taking 5 seconds) <>, you can record: � Message 1 (1 second) <> � Message 2 (1 second) <> � Message 3 (1 second) <> � Message 4 (1 second) <> � Message 5 (4 seconds) <> and combine the messages to obtain the same con- tents, as follows: � Message 1 = Messages 2 + 1 + 5 � Message 2 = Messages 3 + 1 + 5 � Message 3 = Messages 4 + 1 + 5 The three regular Messages take 15 seconds while the three Compound Messages take only 8 seconds, thus saving 7 seconds. Teleservice The B-Mod or B-Mod/RX modem and the Kyo300applica- tion from the Security Suite will allow you to provide the Teleservice facility (access to the system via telephone). Teleservice calls can be made by the installer (Teleservice calls to the Control panel require User au- 56 Figure 40 Auxiliary Communicator page

thorization), or by the User (if the Control panel has

been setup to perform the automatic Test Event). When the Control Panel generates a Teleservice call (manually, by User request, or automatically via the Callback or Enable Test Call options (these options must be Enabled), it will dial the programmed numbers (refer to Enable and Telephone number to call) until a call is successful, or until the programmed call At- tempts cycle ends. The layout of Teleservice page as follows. Double call This option will allow the Control Panel to share the telephone line with another answering device (answering machine, fax, etc.). Under normal circum- stances, the device which allows the least number of rings will answer any incoming calls. However, if this option is Enabled, the Control panel will override the other answering device when it recognizes the Double Call sequence. Double Call sequence: the caller must allow no more than 2 rings, then hang up and callback within 60 sec- onds. The Control panel will answer on the first ring of the second call. � The other answering device must be programmed to answer after 3 or more rings. The B-Modmodem manages the Double call option au- tomatically. To access the system over the phone: ring twice and hang up, then call the Control Panel again within 60 sec- onds. Callback If this option is Enabled, the Control panel will call the Enabled telephone numbers (refer to En- able and Telephone number to call on the Teleservice page). In this way, ONLY authorized per- sons can access the Teleservice facility. Enable This check box will allow you to Enable the Teleservice number. � The application will assign the first four Telephone Numbers in the General book (Telephone page) to the Teleservice facility. If you do not wish to use the preset numbers, Disable the corresponding Enable option. Telephone Number to call Select the Teleservice Telephone Numbers from the General book on the Telephone page. � Disabled Telephone Numbers will not be called. Customer Code This Code will allow the Central Sta- tion to identify the Control Panel. � Any changes made to the Customer code on the Teleservice page will affect the Customer code in the Customer Data window and vice versa. Attempts This programming field will allow you to pro- gram the maximum number of call attempts. Valid entries: 1 through 99 At default: 8 � Enable Test Event If this option is Enabled, the Control panel will make regular Test Calls. The Test call confirms that the Con- trol Panel is operating properly. If the Control panel fails to transmit to the Central station for a long period, it may mean: — the system is operating properly but no events have occurred or, — there is a breakdown in transmissions. If the Central station does not receive the Test Call at the set time, it will be assumed that there is a break- down in transmissions. To set up the Test call, use the Test event and/or Teleservice, as follows. Enable Test Call If this option is Enabled, the Control Panel will make the Test call at regular intervals, in accor- dance with theFirst Test and Repeat test event settings. KYO 300-KYO100 PROGRAMMING 57 Figure 41 Voice Messages page

� If the Enable Test Event is Disabled, the Control

panel will not send the Test call. Enable Test Event If this option is Enabled, the Con- trol panel will generate the Test event in accordance with the First Test and Repeat test event parameters. If this option is Disabled (at default), the Test event will be inhibited. First Test This programming field is for the date and time of the first Test. � Subsequent Test calls depend on the Repeat test event setting. Repeat test event This programming field is for the in- terval between Test calls. Initialize If you are downloading a new Test setting to the Control panel, you must select this button, other- wise the new setting will be ignored. � If the entered date and time are prior to the current date and time on the computer, the Initialize but- ton will be inhibited. The Control Panel must be connected to the PC via serial port or telephone. � Installer Maintenance The Installer Maintenance section will allow you to program the date and time of Installer Maintenance Re- quest signal. TheInstaller Maintenance Request will be signalled by the: � Installer Maintenance event; � ON status of the G indicator on the keypad. � The Trouble indicator G signals various Trouble events. The Trouble details can be found on the LCD Keypads (in View Mode). If the trouble is re- lated to an Installer Maintenance Request, the relevant message will be shown (see the Descrip- tion field in the Installer Maintenance section). The Trouble signal generated by the Installer Mainte- nance Request and Installer Maintenance will termi- nate when: � the Teleservice page is downloaded; � the Date and Time of Installer Maintenance are pro- grammed at the Keypad (refer to “Teleservice” in the KEYPAD PROGRAMMING MANUAL). To set up the Installer Maintenance Request — Enable the Maintenance Request option and set the Date and Time, as follows. Date Enter the date of the Installer Maintenance Re- quest signal. Time Enter the time of Installer Maintenance Request signal. Description Edit the message that will be shown on Keypad (in View Mode) when an Installer Maintenance Request is received. � Central Station Maintenance The Central Station Maintenance section will allow you to program the date and time of the Monitoring Maintenance Request signal. The Monitoring Maintenance Request will be signalled by the : � Central station maintenance event; � ON status of G indicator on the keypad. � The Trouble G indicator signals various Trouble events. The Trouble details can be found on the LCD Keypads (in View Mode). If the trouble is re- lated to a Monitoring Maintenance Request, the relevant message will be shown (refer to the De- scription field in the Central station maintenance section). The Trouble signal generated by the Central station maintenance request and the Central station mainte- nance event will terminate when: 58 Figure 42 Teleservice page

� the Teleservice page is downloaded;

� the Date and Time of Monitoring Maintenance are programmed at the Keypad (refer to “Teleservice” in the KEYPAD PROGRAMMING MANUAL). You must Enable the Central Station Maintenance option and set the Date and Time, as follows. Date Enter the Date of the Central Station Mainte- nance Request signal. Time Enter Time of the Central Station Maintenance Request signal. Description Enter the message that will be shown on the Keypad (in View Mode) when a Central Station Maintenance Request is received. Logger – Events setup The Events setup page will allow you to select the Events that will be recorded in the Logger, and those that will be printed, as follows. � The Event Printout is an accessory feature, and is provided by the optional K3-PRT Printer Interface (refer to “K3-PRT Printer Interface” in the APPENDIX). No. This is the Event ID Number. Description This is the Event label. Enabled Select the Events that will be recorded in the Logger. Printer Select the Events that will be printed. Events-Actions The Events-Actions page determines how the system will operate. The Table in the Events-Actions page will allow you to associate the Events (managed by the Control Panel) with the Output, Digital Communicator and Dialler Ac- tions, as follows. No. This is the Event ID Number. Description This is the Event label: � the round brackets show the label of the device (Key- pad, Reader, etc.) that is associated with the “Object” (Zone, Code, Key, etc.) that generated the event; � the square brackets show the Description of the “Ob- ject” (Zone, Code, Key, etc.) that generated the event. � The events shown depend on the selected detail level (see “Events Details”). Output The ON column is for the ID number of the Out- put that must activate when the Event in question oc- curs (refer to No. column on the Outputs page). Enter 0 if the event is not to activate any Output. � You can select the required Output by double click- ing the corresponding cell in the Output column. Dig. Comm. The ON column is for the ID Number of the Actions the Digital Communicator must generate when the Event in question starts (see No. column in the Actions window on the Digital Communicator page) . The OFF column is for the ID Numbers of the Actions the Digital Communicator must generate when the Event in question ends (see No. column in the Actions window on the Digital Communicator page). Enter 0 in the ON or OFF column if the Digital Commu- nicator for NO Actions. � You can associate the Digital Communicator Ac- tion with the Event by double clicking the corre- sponding cell in the Dig. Comm. ON or Dig. Comm. OFF column. Dialler The ON column is for the ID Numbers of the Ac- tions the Dialler must generate when the Event in question starts (see No. column in the Actions window on the Dialler page). The OFF column is for the ID Numbers of the Actions the Dialler must generate when the Event in question ends (see No. column in the Actions window on the Dialler page). Enter 0 in the ON or OFF column if the Dialler is not to generate any Actions. � You can associate the Dialler Action with the Event by double clicking the corresponding cell in the Dialler ON or Dialler OFF column. � Telephone action priority Priority Actions will override all other Actions in the call queue. The Digital Communicator Action marked with an excla- mation mark (refer to “Actions” in the “Digital Communi- cator” section) has priority over all other Telephone Actions. The Dialler Action marked with an exclamation mark (refer to “Actions” in the “Dialler” section) has pri- ority over all other Telephone Actions except the priority Action set for the Digital Communicator. � The priority Telephone Actions are useful in situa- tions that require quick intervention, such as Medi- cal emergency and Duress. KYO 300-KYO100 PROGRAMMING 59

A The IMQ-SECURITY SYSTEM Approval applies

only when Telephone actions associated with Panic events (e.g. “Alarm zone no.” events with the Panic attribute; “Recognized Code no. events with the Duress attribute; “Special Panic Alarm on Parti- tion no. events)are Priority Telephone Actions. � Colours The Colours button will allow you to assign a colour to each group of events. � Events Details The Events Details button will allow you to filter the events that will be shown, as follows. Highlight programmed events If you Enable this op- tion, Events with AT LEAST ONE associated Action (on an Output, Digital Communicator or Dialler) will be dis- played in bold face. Show only programmed events If you Enable this option, only the Events with AT LEAST ONE associated Action (on an Output, Digital Communicator or Dialler) will be shown. None If you Enable this option, AllEvents will be displayed. Zone If you Enable this option, all the Zone events will be shown. If this option is Disabled, the Zone events will be grouped into the following *Global* Events: � Alarm on zone *Global* � Alarm on zone Via Radio *Global* � Tamper on zone *Global* � Tamper on zone via radio *Global* � Bypass zone *Global* � Bypass zone Via Radio *Global* � Real time of zone *Global* � Real time of zone Via Radio *Global* Partition If you Enable this option, all the Partition events will be shown. If this option is Disabled, the Partition events will be grouped in the following *Global* Events: � Fire alarm on partition *Global* � 24h alarm on partition *Global* � Burglar alarm on partition *Global* � Generic alarm on partition *Global* � Tamper alarm on partition *Global* � Generic+Tamper alarm on partition *Global* � Away alarm on partition *Global* � Stay alarm on partition *Global* � Not Ready-to-arm partition *Global* � Extended not Ready-to-arm partition *Global* � Partial arming partition *Global* � Global arming partition *Global* � Disarming partition *Global* � Exit time on partition *Global* � Entry time on partition *Global* � Autoarming warning partition *Global* � Memory alarm on partition *Global* � Memory tamper on partition *Global* � Alarm stop on partition *Global* � Reset on partition *Global* � Chime on partition *Global* � Event negligence on partition *Global* � Event delinquency on partition *Global* � Memory alarm on partition (VDS) *Global* � Panic alarm on partition (VDS) *Global* � Tamper alarm on partition (VDS) *Global* Digital Key If you Enable this option, all the Key events will be shown. If this option is Disabled, the Key events will be grouped in the following *Global* Event: � Valid Key *Global* Output If you Enable this option, the Supervised Out- put events will be shown. If this option is Disabled, the Supervised Output events will be grouped in the follow- ing *Global* Event: � Tamper on supervised output *Global* Keypad If you Enable this option, the Keypad events will be shown. If this option is Disabled, the Partition events will be grouped in the following *Global* Event: 60 Figure 43 Event-Actions page

� Block keypad *Global*

� Recognized user code on Keypad *Global* FAP Key If you Enable this option, the Super Key events will be shown. If this option is Disabled, the Super Key events will be grouped in the following *Global* Event: � Super key *Global* Keypad Codes If you Enable this option, all the Code events will be shown. If this option is Disabled, the Code events will be grouped in the following *Global* Event: � Recognized user code *Global* User Events If you Enable this option, all the Custom- ized Events will be shown. If this option is Disabled, the Customized Events will be grouped in the following *Global* Event: � User event *Global* Timer If you Enable this option, all the Timer events will be shown. If this option is Disabled, the Timer Events will be grouped in the following *Global* Event: � Timer *Global* Reader If you Enable this option, all the Reader events will be shown. If this option is Disabled, the Reader Events will be grouped in the following *Global* Event: � Key present on reader *Global* � You CANNOT associate Actions with Global Events as they re not single events but represent groups of Events that would not otherwise be shown. Show events concerning The drop-down menu in this section (opened by clicking the arrow) will allow you to filter the details of the Events (Enabled in the Show Details section) that will be viewable, as follows. � All: ALL the events concerning the Enabled Event Types will be viewable. � Zone: ONLY the events concerning the specified Zone will be viewable (the Zone ID Number must be entered in the small box). � Partition: ONLY the events concerning the specified Partition will be viewable (the Partition ID Number must be entered in the small box). � System: ONLY the System events will be viewable. � Digital Key: ONLY the events concerning the speci- fied Key will be viewable (the Key ID Number must be entered in the small box). � Output: ONLY the events concerning the specified Supervised Output will be viewable (the Output ID Number must be entered in the small box). � Keypad: ONLY the events concerning the specified Keypad will be viewable (the Keypad ID Number must be entered in the small box). � FAP Key: ONLY the events concerning the specified SuperKey will be viewable (the SuperKey Number must be entered in the small box). � Keypad Codes: ONLY the events concerning the specified Keypad Code will be viewable (the Keypad Code ID Number must be entered in the small box). � User events: ONLY the events concerning the speci- fied Customized Event will be viewable (the Customized Event ID Number must be entered in the small box). � Timer: ONLY the events concerning the specified Timer will be viewable (the Timer ID Number must be entered in the small box). � Reader: ONLY the events concerning the specified Reader will be viewable (the Reader ID Number must be entered in the small box). � Clear The Clear button will allow you to delete the Output, Digital Communicator and Dialler Actions. Select the Type of Action to be deleted (Output, Digital Communicator or Dialler), then click OK to confirm the operation. � Find This tool will allow you to find Events quickly. You must enter part, or the entire Event label (Description), then click the button. The application will go to the first Event which contains the entered word or combination of words. Click the button again to continue. � Event Description This section describes the conditions that generate, and terminate each event. Zone Events Table 5 shows Zone events associated with Zone alarm and Zone Tamper events. � The conditions which terminate Zone events (ENDSWHEN...column)arevalidONLYwhentheZone Event is NOT associated with a Monostable Output. If the Zone event is associated with a Monostable Out- put, the event will end when the Output OFF Timeout expires, even if the conditions that triggered the event are still present. In all other cases, the event will end when the conditions clear (see Figure 44). A Zone event can be restored to standby by: � changing the status (Armed/Disarmed) of a Partition the Zone is associated with; � running Alarm Reset from a Keypad (the entered User Code and Keypad must be jointly enabled on a Partition the Zone is associated with); � running Alarm Stop from the Keypad (the entered User Code and Keypad must be jointly enabled on a Partition the Zone is associated with); � Using a valid Digital Key/Card at a Reader (both Digi- tal Key and Reader must be jointly Enabled on a Par- tition the Zone is associated with). Partition Events Table 6 shows the Partition Events. The Partition Events encase the Zone Events (Fire, 24h, Burglar, etc.). Each Zone event will in turn generate a KYO 300-KYO100 PROGRAMMING 61

Partition event (on the Partition the Zone is associated

with). The Partition event will not terminate until all the Zone events end, as follows: � The conditions which terminate Partition Events (ENDS WHEN ... column) are valid ONLY when the Partition Event is NOT associated with a Mono- stable Output. Zone Events which are associated with a Monostable Output will not terminate until the Output OFF Timeout has expired (see Figure 44). Partition Events can be restored to standby by: � changing the Partition status (Armed/Disarmed); � running Alarm Reset from a Keypad (the entered User Code and Keypad must be jointly enabled on the Partition in question); � running Alarm Stop from the Keypad (the entered User Code and Keypad must be jointly enabled on the Partition in question) � Using a valid Digital Key/Card at a Reader (both Digi- tal Key and Reader must be jointly enabled on the Partition in question).Control Panel Events Table 7 shows the Control panel Events. The Control panel events comprise all the Zone Events (Fire, 24h, Burglar, etc.) but are totally independent of the Partitions. Con- trol panel events will be generated when the events they comprise occur, and will not terminate until all the events they comprise have ended. � The conditions which terminate the Control Panel Events (ENDS WHEN ... column) are valid ONLY when the Control Panel Event is NOT associated with a Monostable Output. Control Panel Events associated with Monostable Out- puts will not terminate until the Output OFF Timeout has expired (see Figure 44). Control Panel Events can be restored to standby by: � running Alarm Reset from a Keypad (the entered User Code must be enabled for Control Panel Reset — refer to “Keypad codes - Codes types”); � running Alarm Stop from a Keypad (the entered User Code must be enabled for Stop alarms — re- fer to “Digital keys”); � using a Digital Key/Card at a Reader (the Digital Key/Card must be enabled for Stop alarms, refer to “Digital keys”). 62 EVENT OCCURS WHEN... ENDS WHEN... 0001 (0001- 0136) 0280 Alarm on zone no. ... the zone detects Alarm conditions10 ... the zone restores to standby status 0281 (0137 0168) 0312 Alarm on zone no. – Via Radio ... the Wireless zone detects Alarm11 condi- tions ... the Wireless zone restores to standby 0313 (0159- 0304) 0592 Tamper on zone no. ... the zone detects Tamper conditions ... Tamper conditions are no longer present on the zone 0593 (0305- 0336) 0624 Tamper on Zone no. – Via Radio … the Wireless Zone detects Tamper con- ditions ... Tamper conditions are no longer present on the Wireless zone Table 5 Zone Events — The Event numbers for KYO 100 are those in brackets (....) 10The conditions that trigger Alarm and Tamper status on Hardwired Zones depend on the settings programmed on the BPI Zones page. 11The conditions that trigger Alarm and Tamper status on Wireless Zones depend on the settings programmed on the Via Radio (Wireless) page. 10The conditions that trigger Alarm and Tamper status on Hardwired Zones depend on the settings programmed on the BPI Zones page. 11The conditions that trigger Alarm and Tamper status on Wireless Zones depend on the settings programmed on the Via Radio (Wireless) page.

Generic Events These are Control Panel-generated

warnings (e.g. Power Failure). � The conditions which end a Generic Event (ENDS WHEN ... column) are only valid when the Generic Event is NOT associated with a Mono- stable Output. If a Generic Event is associated with a Monostable Out- put, it will not terminate until the Output-OFF Timeout has expired (even if the trouble clears before); in all other cases it will terminate when the trouble has been cleared (see Figure 45). Generic Events can be restored to standby by: KYO 300-KYO100 PROGRAMMING 63 ... alarm ... standby ZONE ... onset ... on standby Monostable OUTPUT ON time OFF time ... onset ... end Zone EVENT ON time OFF time ... onset ... standby Partition/Panel EVENT Figure 44 Zone, Partition and Control Panel event operation — when associated with Monostable Outputs EVENT STARTS WHEN... ENDS WHEN... 0625 (0337- 0352) 0656 Fire alarm on partition no. ...a Fire Zone — associated with the Parti- tion detects Fire Alarm conditions …all events generated by Fire Zones — as- sociated with the Partition restore to standby 0657 (0353- 0368) 0688 24h alarm on partition no. ...a 24h Zone — associated with the Parti- tion detects Alarm conditions ...all events generated by 24h Zones — as- sociated with the Partition restore to standby 0689 (0369- 0384) 0720 Burglar alarm on partition no. ...a Burglar Zone (Instant, Entry delay, En- try path, Exit delay, Last exit) — associ- ated with the Partition detects Alarm conditions ...all events generated by Burglar Zones — associated with the Partition restore to standby 0721 (0385- 0400) 0752 Generic alarm on partition no. ...a Zone (any type) — associated with the Partition detects Alarm conditions ... all Alarm events generated by Zones — associated with the Partition restore to standby 0753 (0401- 0416) 0784 Tamper alarm on partition no. ...a Zone — associated with the Partition detects Tamper conditions ...all Tamper events generated by Zones — associated with the Partition restore to standby 0785 (0417- 0432) 0816 Generic+ Tamper alarm on partition no. ...a Zone— associated with the Partition de- tects Alarm or Tamper conditions ...all Alarm and Tamper events generated by Zones — associated with the Partition restore to standby 0817 (0433- 0448) 0848 Away alarm on partition no. ...the Generic+Tamper alarm on partition event is triggered during Away mode ...the Generic+Tamper alarm on partition event ends 0849 (0449- 0464) 0880 Stay alarm on partition no. ...the Generic+Tamper alarm on parti- tion no. event is triggered during Stay mode ...the Generic+Tamper alarm on parti- tion no. event ends Table 6 Partition Events — The Event numbers for KYO 100 are those in brackets (....).

� running Alarm Reset from a Keypad (the entered

User Code must be enabled for Control Panel Reset — refer to “Keypad codes - Codes types”); � running Alarm Stop from a Keypad (the entered User Code must be enabled for Stop alarms — re- fer to “Digital keys”); � using a Digital Key/Card at a Reader (the Digital Key/Card must be enabled for Stop alarms — refer to “Digital keys”). Spot Events Spot events (see Table 9), such as Rec- ognized User Code, are instant. Therefore, any action undertaken on termination would serve no purpose. Therefore: � Bistable Outputs CANNOT be associated with Spot Events; � Dialler and Digital Communicator Actions CANNOT be associated with restoral of Spot Events. Customized Events These events (refer to Table 10) can be set up to suit particular system requirements. Each Customized Event is generated by the combined effect of two other events (to be programmed in the Customized event settings window). This feature is useful in commercial buildings where, for security reasons for example, two Codes must be entered within a 2 minute window to open a protected door. To set up a Customized Event — select the required event, right click on the mouse, then click Define. Refer to “Customized event settings” for the pro- gramming instructions. Special Events The Special Events (refer to Table 11) operate differently to other event types, as follows. When a Memory alarm on partition (VDS) no. occurs: � if the Partition is Armed in Stay mode, the Control Panel will send the Digital Communicator action and activate the relevant Output; � if the Partition is Armed in Away mode, the Control Panel will send the relevant Digital Communicator call; if the Digital Communicator call is unsuccessful, the Control Panel WILL activate the Output associ- ated with the Event. � Dialler Actions CANNOT be associated with the Memory alarm on partition (VDS) and Tamper alarm on partition (VDS) events. 64 EVENT STARTS WHEN... ENDS WHEN... 0881 (0465) Fire alarm on panel ...a Fire zone — regardless of its Partition detects Fire Alarm conditions ...All events generated by the Fire zones of all Partitions restore to standby 0882 (0466) 24h alarm on panel ...a 24h zone — regardless of its Partition detects Alarm conditions …all events generated by the 24h zones of all Partitions restore to standby 0883 (0467) Burglar alarm on panel ...a Burglar zone — regardless of its Parti- tion detects Alarm conditions (Instant, En- try delay, Entry path, Exit delay, Last exit) ...All events generated by the Burglar zones of all Partitions restore to standby 0884 (0468) Generic alarm on panel ...a Zone — regardless of its Type and Par- tition detects Alarm conditions …All events generated by the zones of all Partitions restore to standby 0885 (0469) Tamper alarm on panel ...a Zone — regardless of its Partition de- tects Tamper conditions ...All Tamper events generated by the zones of all Partitions restore to standby 0886 (0470) Generic+ Tamper alarm on panel ...a Zone — regardless of its Partition de- tects Alarm or Tamper conditions …All Alarm and Tamper events gener- ated by the zones of all Partitions restore to standby 0887 (0471) Tamper on Main unit ...the Control Panel Tamper switch 3 and Snatch switch 12 trip ...the Tamper and Snatch switches are re- stored 0888 (0472) Stop-alarms jumper ... the STOP ALARMS jumper 50 is inserted ...the STOP ALARMS 50 is removed 0889 (0473) Balanced tamper ...the [ASB] terminal is unbalanced … the [ASB] terminal is balanced (grounded with a 10000 ohm resistor) 0890 : 0892 Tamper on supervised output no. ...a Supervised Output is tampered12 ...the Output tamper event ends 0893 (0474) Tamper BPI readers ...the Proximity reader Tamper switch 95 or Snatch switch 87 trips ...the Proximity reader Tamper and Snatch restore 0894 (0475) Tamper BPI input expanders ...the Tamper switch 101 or Snatch switch 96 of an Input Expander with the same BPI bus Address trips ...the Tamper and Snatch switches of all In- put Expanders are closed, and NO two Ex- panders have the same BPI bus address13 Table 7 Control panel events — The Event numbers for KYO 100 are those in brackets (....) 12The conditions that will trigger Tamper on Supervised Outputs are described in the “Outputs” paragraph. 13It may take up to 5 minutes for this event to clear. 12The conditions that will trigger Tamper on Supervised Outputs are described in the “Outputs” paragraph. 13It may take up to 5 minutes for this event to clear.

� The i on the Keypad WILL NOT signal Dialler or

Digital Communicator calls related to Panic alarm on partition (VDS). When aTamper alarm on partition (VDS) no. occurs: � if the Partition is Armed in Stay mode, the Control Panel will send the relevant Digital Communicator call but WILL NOT activate the Output associated with the Event; � if the Partition is Armed in Away mode, the Control Panel will send the relevant Digital Communicator call; if the Digital Communicator call is unsuccessful, the Control Panel WILL activate the Output associ- ated with the Event. � The Dialler Actions CANNOT be associated with the Tamper alarm on partition (VDS) no.Custom- ized Event Settings Setup the Customized Event, as follows. KYO 300-KYO100 PROGRAMMING 65 EVENT STARTS WHEN... ENDS WHEN... 0900 (0481) Warning readers ...an enrolled Reader does not respond to the Control Panel ...ALL Readers respond to the Control Panel 0901 (0482) Warning BPI input expander ...an enrolled Input Expander does not re- spond to the Control Panel ...ALL Input Expanders respond to the Con- trol Panel 0902 (0483) Warning keypads ...an enrolled Keypad does not respond to the Control Panel ...ALL Keypads respond to the Control Panel 0903 (0484) Missing LED Keypad .an enrolled LED Keypad does not respond to the Control Panel ALL LED Keypads respond to the Control Panel 0904 (0485) Warning output expanders ...an enrolled Output Expander does not re- spond to the Control Panel ...ALL Output Expanders respond to the Control Panel 0905 (0486) Warning power stations ...an enrolled Power Supply Station does not respond to the Control Panel ....ALL Power Supply Stations respond to the Control Panel Table 8 Generic Events (continued on next page) — The Event numbers for KYO 100 are those in brackets (....) ... low ... charge BATTERY ... onset ... on standby Monostable OUTPUT ON time OFF time ... onset ... end Low battery EVENT OFF time ON time Figure 45 Operation of Generic Events associated with Monostable Outputs EVENT STARTS WHEN... ENDS WHEN... 0895 (0476) Tamper keypads ...the Keypad Tamper switch 75 or Snatch switch 79 is tripped, or there are at least two Keypads with the same BPI bus Address ...the Tamper and Snatch switches of all Keypads are closed, and NO two Keypads have the same BPI bus Address12 0896 (0477) keypadTamper LED ...the Keypad Tamper switch 75 or Snatch switch 79 is tripped, or there are at least two Keypads with the same BPI bus Address ...the Tamper and Snatch switches of all Keypads are closed, and NO two Keypads have the same BPI bus Address12 0897 (0478) Tamper output expanders ...the Output Expander Tamper switch 101 or Snatch switch 96 is tripped, or there are at least two Output Expanders with the same BPI bus Address ...the Tamper and Snatch switches of all Output Expanders are closed, and NO two Output Expanders have the same BPI bus Address12 0898 (0479) Tamper power stations ...the Tamper switch or Snatch switch of a Power Supply Station is tripped ...the Tamper and Snatch switches of all Power Supply Stations are closed 0899 (0480) Tamper wireless device ...the Tamper switch or Snatch switch of a VectorRX Receiver is tripped ...the Tamper and Snatch switches of all VectorRX Receivers are closed Table 7 Control panel events

...the VectorRX Receiver does not respond

to the Control Panel ...The VectorRX Receiver responds to the Control Panel 0907 (0488) False key ...a false Key/Card is used at a Reader ...ALL false Keys/Cards have been with- drawn from the Readers 0908 (0489) Warning fuse +F ...fuse 37 blows ...fuse 37 is replaced 0909 Warning fuse +F1 ...fuse 36 blows ...fuse 36 is replaced 0910 (0490) Warning fuse +B1 ...fuse 46 blows ...fuse 46 is replaced 0911 Warning fuse +B2 ...fuse 45 blows ...fuse 45 is replaced 0912 Warning fuse +B3 ...fuse 44 blows ...fuse 44 is replaced 0913 Warning fuse +B4 ...fuse 43 blows ...fuse 43 is replaced 0914 Warning fuse +B5 ...fuse 42 blows ...fuse 42 is replaced 0915 (0491) Warning fuse BPI1 ...fuse 35 blows ...fuse 35 is replaced 0916 (0492) Warning fuse BPI2 ...fuse 34 blows ...fuse 34 is replaced 0917 (0493) Warning fuse KEYBUS ...fuse 29 blows ...fuse 29 is replaced 0918 (0494) Warning mains failure ...Mains power has been off for the pro- grammed Timeout (refer to "Options") ...Mains power is restored 0919 (0495) Warning low battery ...Battery voltage drops below 11.4V ...Battery voltage is restored to 12.3V 0920 (0496) Warning power trouble ...a Battery fails the Dynamic Test (refer to "Connecting the Power supply" under "INSTALLINGTHEKYO300"),orfuse60 blows ...Battery meets the Dynamic Test require- ments, or fuse 60 is replaced 0921 (0497) Warning mains failure on Power station ...the programmed Timeout expires (refer to "Power stations" under “Configuration”). The Timeout will start when the Control panel de- tects failure of the Mains supply — to one of the BPI Bus Power Supply Stations. ...Mains power is restored to ALL the BPI Bus Power Supply Stations 0922 (0498) Warning low battery on Power station ...the Battery Voltage of a BPI Power Sup- ply Station drops below 11.4V ...the Battery voltage of ALL BPI Power Supply Stations restores to 12.3V 0923 (0499) Warning power trouble on Power station ...the Battery of a BPI Bus Power Supply Station fails the Dynamic test, and there- fore, is unable to feed and ensure proper functioning of the peripherals; or the Power Supply Station polarity inversion fuse blows ...the Batteries of ALL the BPI Bus Power Supply Stations pass the Dynamic test, or ALL the Power Supply Station polarity in- version fuses are replaced 0924 (0500) Battery not connected on Power station ...the voltage of a Power station battery drops below 10.2 V the voltage of ALL the Power station batter- ies rises above 10.2V 0925 (0501) Battery charger trouble on Power station ...the output voltage of a Power station power supply module is 0.5 V above or be- low the preset value14 ...the output voltage of ALL the Power sta- tion power supply modules is 0.5 V above or below the preset value 0926 (0502) Switching not connected on Power station ...the output voltage of a Power station power supply module is 0.5 V above the preset value ...the output voltage of ALL the Power sta- tion power supply modules is 0.5 V below or equal to the preset value 0927 (0503) Short circuit output 1/2/3 on Power station ...the current draw of a Power station output is over 1.8 A ...the current draw of ALL the Power station outputs is over 1.8 A Table 8 Generic Events (continued on next page) The Event numbers for KYO 100 are those in brackets (....) 14If the Power station is not equipped with a Thermal probe, the preset output voltage will be 13.8 V. If the Power station is equipped with a Thermal probe, the output voltage will depend on the probe temperature. 14If the Power station is not equipped with a Thermal probe, the preset output voltage will be 13.8 V. If the Power station is equipped with a Thermal probe, the output voltage will depend on the probe temperature.

…2 years have passed since the last Reset

Battery Memory expired operation ...the Reset Battery Memory operation is done (refer to "Reset Warning Lithium" un- der "KEYPAD OPERATIONS" in the PROGRAMMING FROM KEYPAD MANUAL) 0929 (0505) Warning low battery on wireless device ...the battery of at least one Wireless Sen- sor is low ...the last Wireless sensor has closed and ALL Wireless Sensor batteries are charged 0930 (0506) Memory tamper BPI device ...the Control panel detects one of the fol- lowing Events: Tamper BPI readers, Tam- per BPI input expanders, Tamper keypads, Tamper output expanders, Tamper power station ...the Control Panel Resets 0931 (0507) Memory balanced tamper ...Balanced tamper event is detected ...the Control Panel Resets 0932 (0508) Memory tamper on main unit ...Tamper on Main unit event is detected ...the Control Panel Resets 0933 (0509) Memory false key ... False key event is detected ...the Control Panel Resets 0934 Memory tamper supervised output ...at least one Tamper on supervised out- put event is detected ...the Control Panel Resets 0935 Trouble auxiliary communicator (VDS) …the Auxiliary Communicator does not re- spond to the Control panel ...the Auxiliary Communicator responds to the Control panel 0936 (0510) Lost wireless zone ...at least one of the Wireless Sensors of a Supervised Wireless zone fails to send a valid signal within the Supervision Time ...ALL Wireless Sensors send valid signals within the Supervision Time 0937 (0511) Warning generic ...at least one of the following events occurs: Stop-alarms jumper, Warning fuse +F, Warning fuse +F1, Warning fuse +B1, Warning fuse +B2, Warning fuse +B3, Warning fuse +B4, Warning fuse +B5, Warning fuse +BPI1, Warning fuse +BPI2, Warning fuse KEYBUS, Warning mains failure, Warning low battery, Warning mains failure on Power station, Warning low battery on Power station, Warning power trouble on Power station, Battery not connected on Power station, Battery charger trouble on Power station, Switching not connected on Power sta- tion, Short circuit output ½/3 on Power station, Warning power trouble, Battery Low Memory, Warning low battery on wireless device, Trouble auxiliary com- municator (VDS), Installer maintenance, Central Station maintenance, Telephone line trouble; or the Control panel cannot find the Voice board, the Control Panel clock is wrong (because the microprocessor has been reset), the Control Panel has been pro- grammed from the PC ...ALL the listed events clear or, the Control panel finds the Voice board; the Control Panel clock is set properly; the Reset Pro- gramming from PC operation is done; the Reset lith. batt. operation is done 0938 (0512) Installer maintenance …the Control panel clock reaches the Time and Date programmed in the Installer main- tenance section on the Teleservice page ...the Teleservice page is downloaded or the Date and Time for Installer Mainte- nance are programmed from a Keypad 0939 (0513) Central station maintenance ...the Control panel clock reaches the Time and Date programmed in the Central station Main- tenance section on the Teleservice page ...the Teleservice page is downloaded or the Date and Time for Central station main- tenance are programmed from a Keypad Table 8 Generic Events — The Event numbers for KYO 100 are those in brackets (....)

...the Enable automatic update standard

time/summer time option is enabled and: the Control panel clock reaches 02.00 hours on the last Sunday in March (switch to daylight saving time) or, at 03.00 hours on the last Sunday in Octo- ber (switch back to standard time) ...the [Upd.leg.sum.time] message is shown on a keypad display in View Trouble mode 0941 (0515- 0530) 0972 Not Ready-to-arm partition no. ...the Partition Disarms AND: at least one of the Extended not Ready-to-Arm Command Zones associated with the Partition detects Alarm conditions OR, at least one of the Zones of the Partition detects Alarm conditions and the Zone IS NOT: — Bypassed or being Tested — an Exit delay or Last exit zone — Autobypassable or Autobypass with reset unbypass or Delayed and esti- mated on ready to arm (the event may be triggered with a delay of up to 2 seconds) ...ALL the Zones listed in the “STARTS WHEN” field restore to standby (the event may take up to 2 seconds to end) 0973 (0531- 0546) 1004 Extended not Ready-to-Arm partition no. …the Partition Disarms AND: ALL the Extended Ready-to-Arm Com- mand Zones associated with the Partition restore to Standby OR, one of the following events occurs: Not Ready-to-arm partition no., Tamper on Main unit, Balanced tamper, Tamper on supervised output, Warning mains failure on Power station, Warning low battery on Power station, Warning power trouble on Power station,Memory balanced tamper, Memory tamper on main unit, Memory tamper supervised output, Warning generic, Memory alarm on partition no., Memory tamper on parti- tion no. ...the Partition Disarms AND: ALL the listed events clear, AND at least one Extended Ready-to-Arm Command Zones belonging to the Partition generates an Alarm ... the Partition is Armed in Away Mode AND, at least one Extended Ready-to-Arm Command Zone belonging to the Partition generates an Alarm OR, terminates the Extended Ready-to-Arm Delay for the Partition. 1005 (0547- 0562) 1036 Partial arming partition no. ...the Partition Arms in Stay Mode with Zero Delay ...the Partition Arms in Away Mode or Dis- arms 1037 (0563- 0578) 1068 Global arming partition no. …the Partition Arms in Away Mode ...the Partition Arms in Stay Mode or Stay Mode with Zero Delay 1069 (0579- 0594) 1100 Disarming partition no. ...the Partition Disarms ...the Partition Arms in Away Mode or Stay Mode or Stay with Zero Delay Mode 1101 (0595- 0610) 1132 Exit time on partition no. ...the Partition Arms in Stay or Away Mode ...the Partition Output Time expires 1133 (0611- 0626) 1164 Entry time on partition no. ...one of the Entry delay Zones belonging to the Partition detects Alarm conditions and the Partition is Armed in Stay or Away Mode ...the Partition Input Time expires or the Partition Disarms 1165 (0627- 0642) 1196 Autoarming warning partition no. …the Control panel signals the start of the programmed Auto-Arm Timeout prior to Au- tomatic Arming of the Partition ...the Partition Arms or an Overtime Re- quest is made for the Partition 1197 (0643- 0658) 1228 Memory alarm on partition no. ...the Generic alarm on partition no. Event occurs ...the Partition Resets Table 8 Generic Events — The Event numbers for KYO 100 are those in brackets (....)

Test ..the Control panel clock signals the Time

programmed on the Teleservice page NOT ALLOWED! 2550 (1596- 1611) 2581 Reset on partition no. ...Alarms Reset is requested using a User Code and Keypad jointly enabled for the Partition NOT ALLOWED! 2582 (1612) Reset on panel ... Panel Reset is requested NOT ALLOWED! Table 9 Spot Events (continued on next page) EVENT STARTS WHEN... ENDS WHEN... 1229 (0659- 0674) 1260 Memory tamper on partition no. ...the Tamper alarm on partition no. Event occurs ...the Partition Resets 1261 (0675- 1174) 1760 Valid key no. ...a Key/Card is used at a Reader ...the Key/Card is removed from the Reader 1761 (1175- 1190) 1792 Key present on reader no. ...a valid Key/Card is used at the Reader ...the Key/Card is removed from the Reader 1793 (1191- 1206) 1824 Valid Key on Partition no. ... a valid Key/Card is inserted/held near a Keypad ...the Key/Card is removed from the Reader 1825 (1207- 1222) 1856 Alarm stop on partition no. ...a Stop Alarms request is made using a User Code enabled for the Partition ...the Control panel exits the Stop Alarms phase 1857 (1223) Alarm stop on panel …a Panel Alarm Stop request is made ...the Control panel exits the Panel Alarm Stop phase 1858 (1224- 1359) 2137 Bypass zone no. ...the Zone is bypassed ...Zone no. is restored 2138 (1360- 1391) 2169 Bypass zone no. – Via Radio ...the Wireless Zone is bypassed ...the Wireless Zone is restored 2170 (1392) Telephone line trouble ...the Telephone Line voltage is less than 3V for 45 seconds. If the Telephone line check is disabled (refer to "Telephone"), the event cannot be generated ...the Telephone Line voltage is higher than 3V for 45 seconds 2171 (1393) Error printer …the Printer is either Disconnected; Im- properly connected to the Printer interface; OFF or Not in line (no paper, no ink/toner, blocked, etc.) …the trouble clears 2172 (1394) Call queue full ...the 254th Telephone Action is queued ...there are no Telephone Actions in the Call Queue 2173 (1395- 1426) 2236 Timer no. ...Timer no. switches ON (see Timer page) ... Timer no. switches OFF 2237 (1427- 1594) 2516 Real time of zone no. ...the voltage (resistance) on Zone no. en- ters the Alarm Range ...voltage (resistance) on Zone no. re- stores to Standby Range 2517 ... 2548 Real time of zone no. – Via Radio ...Wireless Zone no. is violated ...Wireless Zone no. returns to standby Table 8 Generic Events — The Event numbers for KYO 100 are those in brackets (....)

Super key [Fire]

[Keypad nnn] …buttons Ì and Í on the Keypad are pressed simultaneously NOT ALLOWED! Super key [Assistance] [Keypad nnn] ...buttons P and p on the Keypad are pressed simultaneously NOT ALLOWED! Super key [Police] [Keypad nnn] ...buttons À and Á on the Keypad are pressed simultaneously NOT ALLOWED! Super key [Key 1] [Keypad nnn] ...button 1 on the Keypad is pressed and held down for 3 seconds NOT ALLOWED! Super key [Key 2] [Keypad nnn] ...button 2 on the Keypad is pressed and held down for 3 seconds NOT ALLOWED! Super key [Key 3] [Keypad nnn] ...button 3 on the Keypad is pressed and held down for 3 seconds NOT ALLOWED! Key F on KeyFob Pno. …the G button of a Group 1 or Group 2 Wireless key is pressed and held down for 2 seconds NOT ALLOWED! Key A on KeyFob Pno. ...the G button of a Group 1 or Group 2 Wireless key is pressed and held down for 2 seconds NOT ALLOWED! Key P on KeyFob Pno. ...the G button of a Group 1 or Group 2 Wireless key is pressed and held down for 2 seconds NOT ALLOWED! 2829 (1715- 1730) 2860 Chime on partition no. ...a Zone with the Chime Attribute belong- ing to the Partition detects Alarm conditions when the Partition is Disarmed NOT ALLOWED! 2861 (1731- 1746) 2892 Event negligence on partition n. … the Negligence Time expires NOT ALLOWED! 2893 (1747- 1762) 2924 Event delinquency on partition no. ...the Inactivity Time expires NOT ALLOWED! 2925 (1763- 1794) 2972 Block Keypad no. ...the Keypad locks NOT ALLOWED! 2973 (1795- 1891) 3167 Recognized user code no. ....O, o, E, A, B, C or D is pressed af- ter entry of a valid User Code PIN NOT ALLOWED! 3168 (1892- 1923) 3215 Recognized user code on Keypad no. ...a Valid User Code PIN is entered at the Keypad NOT ALLOWED! 3216 (1924- 1939) 3247 Recognized user code on Partition no. ...a Valid User Code PIN is entered for the partition NOT ALLOWED 3248 (1940) Invalid code ....O, o, E, A, B, C or D is pressed af- ter entry of an Invalid User Code PIN NOT ALLOWED! 3249 (1941) Recognized installer code …the Installer Menu is quitted NOT ALLOWED! 3250 (1942) Second dialler on For future use! 3251 (1943) Kissoff recognized ...the Control panel detects the Kissoff tone15 NOT ALLOWED! Table 9 Spot Events (continued ...) — The Event numbers for KYO 100 are those in brackets (....) 15The Kissoff tone is the signal the receiver uses to communicate reception of a data block 15The Kissoff tone is the signal the receiver uses to communicate reception of a data block

Event 1 Enter the ID Number of the first event (associ-

ated with the Customized event), or double click the Event 1 field and select the event from the Table. Event 2 Enter the ID Number of the second event (as- sociated with the Customized event), or double click the Event 2 field and select the event from the Table. � Enter 0 in the Event 1 and Event 2 fields, if the Customized event is not required. NOT If this option is enabled, the Event logic will CHANGEOVER. For example, if the NOT option is enabled for an Alarm on zone event, the event will START when the zone RESTORES TO STANDBY, and END when the zone SIGNALS ALARM STATUS, instead of vice versa. � The NOT option cannot be enabled for Spot Events, and for NON-Spot events with the AND Operator. Window This parameter determines the period within which the associated events (Events 1 and 2) must oc- cur. If these events do not occur within the pro- grammed Window, the system will not generate the Customized event. Disable the NONE option then enter the required value. Valid entries: 1 through 13106 seconds (3 hours, 38 minutes and 26 seconds) in 1 second steps. � The Customized Event can be associated with Spot events (which end almost instantly), and NON-Spot events (which have a duration). If you associate two Spot events with the Custom- ized Event, you MUST program the Window in or- der to provide the Spot events with a “virtual” end. The “virtual” end of Spot events will occur when the Window expires. The Window will start when either Event 1 or Event 2 occurs. � The Window cannot restart until both events end (see Fig. 46: b3). Operator Select the Operator (AND, OR or XOR) for Events 1 and Event 2. The selected Operator deter- KYO 300-KYO100 PROGRAMMING 71 EVENT STARTS WHEN... ENDS WHEN... 3263 (1955- 1986) 3294 Customized event no. ...the logic expression defined for the Cus- tomized Event is true ...the logic expression defined for the Cus- tomized Event is false Table 10 Customized Events EVENT STARTS WHEN... ENDS WHEN... 3252 (1944) Start telephone call ...the Control Panel engages the telephone line NOT ALLOWED! 3253 (1945) Teleservice requested ...the Control Panel answers a Teleservice call NOT ALLOWED! 3254 (1946) Start Teleservice ...the Teleservice connection is generated after recognition of the Installer PIN NOT ALLOWED! 3255 (1947) Dialler action OK ...a Dialler call is successful NOT ALLOWED! 3256 (1948) Action on digital communicator OK ...a Digital Communicator call — using a protocol other than Contact ID — is suc- cessful NOT ALLOWED! 3257 (1949) Digital communicator OK ...a Digital Communicator call — using a protocol other than Contact ID — is suc- cessful NOT ALLOWED! 3258 (1950) Teleservice action OK ...a Teleservice call is successful NOT ALLOWED! 3259 (1951) Dialler action failed ...a Dialler call fails NOT ALLOWED! 3260 (1952) Action on digital communicator failed ...a Digital Communicator call — using a protocol other than Contact ID fails NOT ALLOWED! 3261 (1953) Digital communicator action failed ...a Digital Communicator call — using Contact ID protocol fails NOT ALLOWED! 3262 (1954) Teleservice action failed ...a test call or other user-requested Teleservice call fails NOT ALLOWED! Table 9 Spot Events — The Event numbers for KYO 100 are those in brackets (....)

mines the operating mode of the Customized Event, as

follows. � AND The AND Operator will signal when BOTH the associ- ated events start. The AND Operator depends on the event types (NON-Spot and/or Spot), and on whether or not the Window has been programmed, as follows. � Event 1 and Event 2 NON-Spot, NO Window The system will generate the Customized Event, when Event 1 AND Event 2 start (see Fig. 46: a1 and a3). The system will end the Customized Event when either Event 1 OR Event 2 ends (see Fig. 46: a2 and a4). � Event 1 and Event 2 NON-Spot, WITH Window The system will generate the Customized Event when Event 1 AND Event 2 BOTH start within the pro- grammed Window (see Fig. 46: b1 and b4). The system will end the Customized Event when the programmed Window expires (see Fig. 46: b2 and b5). � One Spot Event and one NON-Spot Event, NO Window The system will generate the Customized Event when the NON-Spot Event starts after the Spot Event (see Fig. 46: c1) or, when the Spot Event starts after the NON-Spot Event (see Fig. 46: c3). The system will end the Customized Event when the NON-Spot Event ends (see Fig. 46: c2 and c4). � One Spot Event and one NON-Spot Event, WITH Window The system will generate the Customized Event when the NON-Spot Event starts after the Spot Event within the Window (see Fig. 46: d1) or, when the Spot Event starts after the NON-Spot event within the Window (see Fig. 46: d3). The system will end the Customized Event when the NON-Spot Event ends (see Fig. 46: d2 and d4). � Event 1 and Event 2 Spot, NO Window � If you apply the AND Operator to two Spot Events, you MUST program the Window. � Event 1 and Event 2 Spot, WITH Window The system will generate the Customized Event when either one of its associated Events starts after the other within the Window (see Fig. 46: e1). The system will end the Customized Event when the Window expires (see Fig. 46: e2). � OR The OR Operator will signal when ONE of the associ- ated events starts. The OR Operator depends on the Event types (NON-Spot and/or Spot), and on whether or not the Window has been programmed, as follows. � Event 1 and Event 2 NON-Spot, NO Window The system will generate the Customized Event when ei- ther Event 1 OREvent 2 starts (see Fig. 47: a1 and a3). The system will end the Customized Event when Event 1 AND Event 2 end (see Fig. 47: a2 and a4). � Event 1 and Event 2 NON-Spot, WITH Window 72 EVENT STARTS WHEN... ENDS WHEN... 3295 (1987- 2002) 3326 Memory alarm on partition (VDS) no. ...the Partition generates an Alarm status (Instant, Entry delay, Entry path, Exit de- lay, Last exit zone) ...the Partition Resets 3327 (2003- 2018) 3358 Panic alarm on partition (VDS) no. ...a Duress Zone belonging to the Partition generates Alarm status NOT ALLOWED! 3359 (2019- 2034) 3390 Tamper alarm on partition (VDS) no. ...a Zone belonging to the Partition gener- ates Tamper status ...all Tamper events generated by the Zones belonging to the Partition restore to Standby 3391 (2035) VDS Trouble ...at least one of the following events occurs: Warning readers, Warning BPI input ex- pander, Warning keypads, Warning out- put expanders, Warning power station, Warning wireless device, Warning mains failure, Warning low battery, Warning power trouble, Warning mains failure on Power station, Warning low battery on Power station, Warning power trouble on Power station, Battery not connected on Power station,Battery charger trouble on Power station, Switching not connected on Power station, Short circuit output ½/3 on Power station, Battery low memory, Telephone line trouble ...ALL events clear (Warning readers, Warning BPI input expander, etc.) 3392 (2036) Memo present … a message is recorded on the Answerphone .....the message is played Table 11 Special Events — The Event numbers for KYO 100 are those in brackets (....)

� If you apply the OR Operator to two NON-Spot

Events, the Window will be uninfluential. � One Spot Event and one NON-Spot Event, NO Window The system will generate the Customized Event when either Event 1 OR Event 2 starts (see Fig. 47: b1, b2, b4, b6 and b8). The system will end the Customized Event when Event 1AND Event 2 end (see Fig. 47: b1, b3, b5, b7 and b8). � If you apply the OR operator to a Spot Event and a NON-Spot event, the Customized Event may in some cases operate as a Spot Event (i.e. end al- most instantly). Therefore, if you assign a Tele- phone Action to the start and end of the Customized Event, the relevant telephone calls will be placed in the Call queue almost instantly. If you assign a Bi- stable Output to the Customized Event, the Output may activate for approximately 1 second. � One Spot Event and one NON-Spot Event, WITH Window The system will generate the Customized Event when Event 1 OREvent 2 starts (see Fig. 47: c1, c3, c5 and c7). The system will end the Customized Event when the NON-Spot Event ends (Fig. 42: c2, c4 and c8) or, when KYO 300-KYO100 PROGRAMMING 73 Event 1 Event 2 Window Event 1 Event 2 AND AND b) c) Event 1 Event 2 AND d) Event 1 Event 2 Window AND e) Event 1 Event 2 Window AND a) 1 2 3 4 1 2 3 1 2 3 4 1 2 3 4 1 2 4 5 Figure 46 The AND Operator mode

the Spot Event ends, and no other NON-Spot Events

have occurred in the meantime (Fig. 42: c6). � Event 1 and Event 2 Spot, NO Window (NOT ALLOWED) � If you apply the OR Operator to two Spot Events, you MUST program the Window. � Event 1 and Event 2 Spot, WITH Window The system will generate the Customized Event when Event 1 OR Event 2 starts (see Fig. 47: d1, d3 and d5). The system will end the Customized Event when the Window expires (see Fig. 47: d2, c4 and d6). � XOR The XOR Operator will signal when the status of Event 1 is different from that of Event 2. The XOR Operator depends on the event types (NON-Spot and/or Spot), and on whether or not the Window has been programmed, as follows. � Event 1 and Event 2 NON-Spot, NO Window The system will generate the Customized Event when the status of Event 1 is different from that of Event 2 (see Fig. 48: a1, a3, a5 and a7). The system will end the Customized Event when the status of Event 1 is the same as that of Event 2 (see Fig. 48: a2, a4, a6 and a8). � Event 1 and Event 2 NON-Spot, WITH Window The system will generate the Customized Event when the status of Event 1 is different from that of Event 2 within the Window (see Fig. 48: b1, b4 and b7). The system will end the Customized Event when the status of Event 1 is the same as that of Event 2 (see Fig. 48: b2, b5 and b9). � The system WILL NOT generate the Customized Event if the status of Event 1 is different from that of Event 2 when the Window is not running (see Fig. 48: b3, b6 and b9). � One Spot Event and one NON-Spot Event, NO Window The system will generate the Customized Event when the status of Event 1 is different from that of Event 2 (see Fig. 48: c1, c2, c4, c7 and c9). The system will end the Customized Event when the status of Event 1 is the same as that of Event 2 (see Fig. 48: c1, c3, c6 and c8), that is, unless the Spot Event starts after the NON Spot event (see Fig. 48: c5). 74 Event 1 Event 2 OR b) Event 1 Event 2 OR c) Event 1 Event 2 Window OR d) Event 1 Event 2 Window OR a) 1 2 3 4 1 3 5 1 2 3 5 1 2 2 4 4 6 7 8 6 7 8 3 5 4 6 Figure 47 The OR Operator mode

� If you apply the XOR operator to a NON-Spot event

and a Spot Event, the Customized event may, in some cases, operate as a Spot Event (i.e. end al- most instantly). Therefore, if you assign a Tele- phone Action to the start and end of the Customized Event, the relevant telephone calls will be placed in the Call queue almost instantly. If you assign a Bi- stable Output to the Customized Event, the Output may activate for approximately 1 second. � One Spot Event and one NON-Spot Event, WITH Window When calculating the XOR result of a Spot Event and a NON-Spot Event, you must consider the Spot Event as ending when the Window expires. Thus the Customized Event will start when the status of Event 1 is diferent from that of Event 2 within the Window (see Fig. 48: d1, d4, d7 and d9). The Customized Event will end when the status of the Event 1 is the same as that of Event 2 (see Fig. 48: d2, d5, d8 and d10). � The system will not generate the Customized event, if the status of Event 1 is different fromthat of Event 2, when the Window is not running (see Fig. 48: b3, b6 and b9). � Event 1 and Event 2 Spot, NO Window (NOT ALLOWED) � If you apply the XOR Operator to two Spot Events, you MUST program the Window. � Event 1 and Event 2 Spot, WITH Window KYO 300-KYO100 PROGRAMMING 75 Event 1 Event 2 Window Event 1 Event 2 XOR XOR b) c) Event 1 Event 2 XOR d) Event 1 Event 2 Window XOR e) Event 1 Event 2 Window XOR a) 1 2 4 5 1 2 4 1 3 4 6 1 2 3 4 1 2 3 5 7 2 5 7 8 9 6 3 5 4 6 5 7 8 9 10 3 6 7 8 6 8 9 Figure 48 The XOR Operator mode

When calculating the XOR result of two Spot Events,

you must consider them as both ending when the Win- dow expires. In this way, the Customized Event will start when the status of Event 1 is different from that of Event 2 (see Fig. 48: e1, e3 and e5). The Customized Event will end when the status of Event 1 is the same as that of Event 2 (see Fig. 48: e2, e4, and e6). Scheduler - Arming You can program the Scheduler to manage up to 16 Day Models (e.g. Weekday, Holidays, etc.), each with up to 4 Arm and 4 Disarm operations per Partition. ! The Scheduler Actions will be ignored during the programming session. You can program the automatic Arm/Disarm parame- ters in the Arming page. To create the Day Models — click the Models tab. Partitions This field shows the Partition Descriptions (to be programmed in the Partitions page). 1st Dis. / 2nd Dis. / 3rd Dis. / 4th Dis. These fields will allow you to set up to 4 Disarm times for the corresponding Partition. Valid format: hh.mm — where hh represents the hour (00 to 23) and mm represents the minutes (00 to 59). For example, to set 7:45 a.m. — enter 07.45. to set 5:45 p.m. enter 17.45. If you enter an invalid value, the application will display an error message. 1st Arm. / 2nd Arm. / 3rd Arm. / 4th Arm. These fields will allow you to set up the automatic arming times for the corresponding Partition. 1st Type / 2nd Type / 3rd Type / 4th Type These fields will allow you to select the Arming Mode (Type) for that Partition: � A = Away � S = Stay � I = Stay with 0 Delay (Instant) � Type Description The Type Descr. button opens a window for the Model labels (Weekday, Half-day, Holiday, Christmas holiday, Summer Holiday, etc.). No. This non-editable field shows the Model ID Num- ber. Description This field will allow you to edit the Model label (maximum 16 characters). � Models The Models button will open the programming window of the parameters described in this section. Day This field will allow you to select the Day number. Valid entries: 1 through 31 or Asterisk *. � If you select an asterisk (*), the Day number (1 through 31) will be irrelevant for the Model. � If you select a Day number, you will not be able to se- lect a Weekday. � If you select an invalid number, the application will automatically rectify it to last day of the relevant month, when you click Download. Month This field will allow you to select the relevant Month. � If you select an asterisk (*) the Month will be uninfluential. Year This field will allow you to select the relevant Year. Valid entries: 2002 through 2016: � If you select an asterisk (*) the Year will be uninfluential. Interval You must select this field, if the corresponding line indicates the Start of an Interval such as: Summer holidays, Bank holiday week-end, Christmas, etc. To program an Interval: select the start of the Interval on one line and the end of the Interval on the following line, then click the Start field. If the entry is valid the words Start and Stop will be shown. Valid entries: 1 through 31 (Day Number) or Monday, Tuesday, etc. (Weekday). � The Interval MUST Start and Stop within the same month. Day of Week This field will allow you to select the rele- vant Day. � If you select an asterisk (*), the Day of the week will be uninfluential. � If you select a Weekday, you will not be able to spec- ify the Day Number (1 through 31). Type This field will allow you to select the Description (label) of the Model. � If you do not select a Description, the corresponding Model will not be saved. � You must select the Description of the Model on the Start line of the interval. You cannot select the De- scription on the Stop line as this field is automatic (*). Sort Models This button will allow you to prioritize the Models. NOTE: Some days may belong to several Models. If this occurs, the Scheduler will apply the Times of the least frequent Model. 76

For example, the Christmas Holiday Model is applied

once a year, therefore, it will take priority over the Weekday Model that is applied 5 days per week. � Options The Options button will open the programming window of the parameters described in this section. Max. Overtime Requests This option will allow you to set the maximum number of Overtime Requests. EXAMPLE: If a Timer controlled Partition is scheduled to Arm at 17:45 — and the Overtime request period is set at 60 minutes, and the Max. No. of Overtime re- quests is set at 2 — Arming can be postponed until 19:45 by two Overtime requests (17:45 + 2 x 60 min- utes), after which, Overtime requests will be ignored. The maximum Overtime request is 180 minutes. � If you select an invalid value, the application will rec- tify it to the highest accepted value. � If you select 0, the program will rectify it to 1. � Overtime Requests will affect the imminent Arming event ONLY. Example: If the 1st Arm event of a Partition is sched- uled for 12:45 and the 2nd Arm event is scheduled for 15:30, and the User makes four 1-hour Overtime Re- quests at 12.30 — with the intention of overlapping the 2nd Arm event (12:45 + 4 h = 16.45), the system will ig- nore the overlap and will Arm the Partition at 15.30 as scheduled. Overtime request This is the delay before a sched- uled Arming Time. Example: If a Partition is scheduled to Arm at 17:45 and the Overtime Request is set at 60 minutes, and the User makes an Overtime Request at 17.30, the Parti- tion will Arm at 18:45 (17:45 + 1 h) unless the User makes further Overtime Requests in the meantime. Valid entries: 0 through 60 minutes, in 1-minute steps. � If you enter a value of over 60 minutes, it will be recti- fied automatically to 60 minutes. � If you enter 0 minutes, Overtime Requests will be ig- nored. � Examples The following Models show: Weekday, Half-day, Bank holiday, Summer holiday and Christmas holiday. Weekdays This Model includes weekdays, regardless of the Day number, Month and Year. The Weekdays Model is an Interval and must be setup on two lines. On the upper line, select an asterisk (*) in the Day, Month and Year fields, and Monday in the Day of Week field. On the lower line, select an asterisk (*) in the Day, Month and Year fields, and Friday in the Day of Week field. Click the Interval field of the upper line: the words Start and Stop will be shown. Select Weekdays in the Type field. DayMonth Year Interval Day of week Type * * * Start Monday Weekdays * * * Stop Friday * Half-day This Model is for Half-day Closing. Select an asterisk (*) in theDay, Month andYear fields, and Saturday in the Day of Week field. Select Half-day in the Type field. DayMonth Year Interval Day of week Type * * * * Saturday Half-day Summer Holiday This Model is an Interval and must be setup on two lines. On the upper line, select the number of the first day of the holiday period (e.g. 8) in the Day field, and the rele- KYO 300-KYO100 PROGRAMMING 77 Figure 49 Scheduler - Arming Page

vant Month in the Month field (e.g. August).

Select an asterisk (*) in the Year and Day of Week fields. On the lower line, select the number of the last day of the holiday period (e.g. 23) in the Day field, and the rele- vant Month in the Month field (e.g. August). Select an asterisk (*) in the Year and Day of Week fields. Click the Interval field of the upper line: the words Start and Stop will be shown. Select Summer holidays in the Type field. DayMonth Year Interval Day of week Type 8 August * Start * Summer Holiday 23 August * Stop * * Christmas Holidays This Model can be setup in the same way as the Summer Holiday period. However, if the Christmas holiday period continues into the New year (e.g. 24th December to 3rd January), it must be setup on two blocks of 2 lines, as follows. � Days from the 24th to the 31st of December in the first block � Days from the 1st to the 2nd of January in the second block. DayMonth Year Interval Day of week Type 24 Dec. * Start * ChristmasHolidays 31 Dec. * Stop * * 1 January * Start * ChristmasHolidays 2 January * Stop * * Bank Holiday This Model is for Bank Holidays. Select the Day number (e.g 20) and Month (e.g. April) in the respective fields. Select Bank holiday in the Type field. DayMonth Year Interval Day of week Type 20 April * * * Bank holiday Model Priority Some days may belong to more than one Model, therefore, the Scheduler will apply the Times of the least frequent Model. For example, Christmas Holiday Model — is applied once a year, therefore, will take priority over the Week- day Model that is applied 5 days per week. Scheduler - Timers You can define up to 16 Models, each with a maximum of 4 different ON and 4 different OFF Times for each of the 64 (32 for KYO 100) Control panel Timers. Each Timer is associated with a Timer Event on the Events-Actions page. When the Timer triggers the ON signal, the correspond- ing Event will occur (e.g. the Garden Sprinkler will turn ON). When the Timer triggers the OFF signal, the corre- sponding Event will be terminated (e.g. the Garden Sprinkler will turn OFF). The ON/OFF operations of each Timer will be recorded in the Logger, as follows: � Type: Timer ON or Timer OFF � IDENT.: Timer Description � TIME: Time and Date of the ON and OFF operations The Timers can be programmed with the ON/OFF Times of domestic appliances such as Garden Sprin- klers, Courtesy lights, Heating systems, etc., or with the ACTIVE/INACTIVE Times of the system Outputs, Codes and Keys. � The user can enable/disable the Timers (refer to “En./Dis. Timers” in the USER MANUAL). If a User disables a Timer during its programmed ON Time, the corresponding Timer event will end. If a User enables a Timer during its programmed ON Time, the corresponding Timer event will start within the minute. Example: If a Timer — with a programmed ON Time of 21.00 to 24.00 — is enabled at 22:02:01 the corre- sponding Timer event will be triggered at 22:03:00 The ENABLE/DISABLE operations of each Timer will be recorded in the Logger, as follows: � Type: Timer Enabled or Timer Disabled � IDENT.: Timer Description � USER: Keypad Description � USER ID.: Code Description � TIME: Time and Date of the ON and OFF operations The Timers page will allow you to program the Timer parameters, as follows. Select the required Day Model, then select the tag of the Day model timer you wish to set up, in the lower part of the table. No. This non-editable field shows the Timer ID Num- ber. Description Enter the relevant Timer label (e.g. Heater, Sprinkler, etc.). This label will be used to iden- tify the Timer in all the operations it is involved in. 1st ON / 2nd ON / 3rd ON / 4th ON This field will al- low you to set the ON Time (refer to 1st Dis. / 2nd Dis. / 3rd Dis. / 4th Dis. for the Time format). 1st OFF / 2nd OFF / 3rd OFF / 4th OFF This field will allow you to set the OFF Time (refer to 1st Dis. / 2nd Dis. / 3rd Dis. / 4th Dis. for the Time format). � Type Description Refer to “Types Description” under “Scheduler - Timers”. 78

Refer to “Models” and “Events” under “Scheduler -

Timers”. Options This page will allow you to setup the options that deter- mine the operating mode of the system. Disable Tamper Memory Reset with User code If this option is enabled, only the Installer Codes will be able to delete the Zone, Partition and Control Panel Tamper memories. Maintain Zone Test Attribute If this option is en- abled, any Alarms generated by Zones in Test status will be recorded in the Events Logger, also when the Partition is Disarmed. Enable dynamic battery test timeout after mains restoral After providing power during a Mains blackout, the bat- tery will be quite low, and therefore, unable to meet the Dynamic Battery Test requirements (refer to “Power supply connection” under “Installation”). If this option is enabled, the Dynamic Battery Test will restart 5 hours after Mains restoral (instead of immediately) thus allow- ing the battery to recharge. Disable Alarm Memory Reset With Installer Code If this option is enabled, only enabled User Codes will be able to delete Alarm memories. LEDs OFF on Readers If this option is enabled, the Reader LEDs will not signal the system status (all LEDs OFF) until a valid Key/Card is used at the Reader. � The LEDs of Readers which have the M option En- abled (refer to “Readers” under “Enrolling”), will al- ways show the status of their associated events, regardless of the status of the LEDs OFF on Readers option. Bypass Tamper on Zone If this option is enabled, by- passed Zones will not generate Tamper Alarms. A The IMQ-SECURITY SYSTEM Approval applies only when the Bypass Tamper on Zone option is Disabled. Disable Arming on Battery Trouble If this option is enabled, Arming requests will be denied when any of the following events is in progress: � Warning low battery � Warning power trouble � Warning low battery on Power station � Warning power trouble on Power station Lock Installer Code If this option is enabled, restoral of the default settings WILL NOT default the PIN of Code no. 200 (MASTER Installer Code). Disable Arming with Partition Alarm If this option is enabled, Arm commands from Keypads or Readers will not be carried out if the system detects Partitions in alarm status. � This option does not apply to Arming operations done via a Command zone, Timer, remote Tele- phone or computer. Enable Automatic Update of Standard Time/Summer Time If this option is en- abled, the Control Panel will manage the Daylight Saving Time changeover automatically, as follows: � the Clock will be put forward 1 hour at 2 am on the last Sunday in March; � the Clock will be put back 1 hour at 3:00 am on the last Sunday in October. The system will signal Automatic Changeover by: � generating the Standard time/Summer time changed event; � switching ON the G LED. � The G LED signals several different types of Trou- ble events. If signalling is due to the Standard time/Summer time changeover, the Keypad (in View Trouble Mode) will show the [daylighttimeUpdt] message. Voice guide for commands via telephone If this option is enabled, the User will be able to access the voice guided menu and operate the system from a remote phone. Access to this facility requires entry of a valid Telephone Access Code. Once the communica- tion has been established, the Control panel will play message 60 which will explain the functions associated with keys 1, 2, 3, 4, 5, 6, 7, 8, 9, # and *. � If key 1 is pressed, the Control panel will play mes- sage 55 which contains the instructions for the DTMF menu Listen-in options, that is, the functions of keys 1, 2 and #. � If key 2 is pressed, the Control panel will play mes- sage 56 which contains the instructions for the DTMF menu Zone and Partition status enquiry options, that is, the functions of keys 1+nnn, and 2+nnn. � If Key 3 is pressed, the Control panel will play mes- sage 57 which contains the instructions for the DTMF menu Activate/Deactivate Reserved Outputs op- tions, that is, the functions of keys 0+nnn, and 1+nnn. � If key 4 is pressed, the Control panel will play mes- sage 58 which contains the instructions for the DTMF menu options, that is, the functions of keys 1, 2, 3, 4, 5 and 6. KYO 300-KYO100 PROGRAMMING 79

� If key 5 is pressed, the Control panel will play mes-

sage 59 which contains the instructions for the DTMF menu Arm/Disarm single Partitions options, that is, the functions of keys 0+nn and 1+nn. Messages 55, 56, 57, 58, 59 and 60 of the Voice Guide must be recorded by the Installer. The Voice Message recording instructions, and some examples of typical messages can be found in the “Voice Message” sec- tion. For example, message 55: “Press 1 to activate Re- mote Listen-In, press 2 to activate the 2-way Audio channel, press # to go back to the Main menu”. � If key 7 is pressed, the Control panel will play mes- sage 54 which contains the instructions for the DTMF menu Record/Play Memos option, that is, key 1 (Re- cord memo) and Key 0 (Play memo). New Teleservice Link-up Enable this option ONLY when Teleservice fails to operate at default settings. Display Zones in Alarm on Keypad If this option is enabled, the LCD Keypad will provide real-time infor- mation — during Disarmed status — regarding Alarm conditions on Zones associated with any of its Parti- tions. Display Chime Zone on Keypad (real-time) If this option is enabled, the LCD Keypad will provide real-time information — during Disarmed status — re- garding Alarm conditions on Chime Zones associated with any of its Partitions. Signalling will stop when the Zones concerned restore automatically to standby status. Display Chime Zone on Keypad (memory) This op- tion is irrelevant if the “Display Chime on Keypad (real-time)” option is disabled. If this option is enabled, the LCD Keypad will provide real-time information — during Disarmed status — re- garding Alarm conditions on Chime Zones associated with any of its Partitions. Signalling will continue until the Partition concerned is reset manually. � The above-mentioned “Display … on Keypad” op- tions will soon be available for programming via Keypad. Enable Continuous Recording If this option is en- abled, the Control Panel will use Message No. 62 to continuously record any sounds picked up by the micro- phones of the Voice board and connected Micro- phone-Speaker boards. If any of the Events listed in the Events enabled to stop continuous recording Table occurs, the Control Panel will stop recording after the programmed Time- out stop continuous recording. In this way, Message No. 62 will record ambient sounds picked up before and after the programmed events (refer to “Continuous Re- cording” in the USER MANUAL). Events Enabled to Stop Continuous Recording If this option is enabled, you will be able to select the Events that will stop the Continuous Record- ing facility. At default, only Generic+Tamper alarm on partition will stop the Continuous Recording facility. To change an Event: 1. Double click on the No. field, or on the field of the Events enabled to stop continuous recording. 2. Select the required Event from the list. 3. Click OK. To delete an Event: 4. Select the No. field of the Event; 5. Press Canc button on the computer keypad. Timeout Stop Continuous Recording This field will allow you to program the interval (in seconds) between the start of an Event — selected on the Events enabled 80 Figure 50 Options page

to stop continuous recording list — and termination

of recording. Valid entries: 0 seconds to 75% of the programmed length of Message No. 62 Default: 10 seconds Lock Keypad on Invalid Code If this option is en- abled, the Keypad will lock for the programmed time (re- fer to “Lock time in min.”) when an Invalid PIN is entered for the programmed number of times (refer “Max. Num- ber of Attempts”). Attempts This field will allow you to program the number of wrong PIN entries allowed before keypad lock out. The wrong PIN counter will reset when the valid PIN is entered or when the Lock Time min. expires. Valid entries:1 through 10. Default: 3 Lock Time min. This field will allow you to set the Key- pad Lock time (in minutes). Valid entries: 1 through 20 minutes, in 1-minute steps Default: 3 minutes Mains Fault Timeout This field will allow you to set the amount of time that must expire before the Warning mains failure event occurs. Valid entries: 0 through 5400 minutes, in 1-minute steps Default: 3 minutes Keypad Codes - User The Keypad Codes and Digital Keys/Cards allow the Users and Installer to access the system. 200 Codes Available for KYO300 (100 for KYO100) T KYO 300 manages a total of 200 Codes — 195 User Codes (1 through 195), 4 Installer Codes (196 through 199) and a Master Installer Code (200). KYO 100 manages a total of 100 Codes — 97 User Codes (1 through 97), 2 Installer Codes (98 and 99) and a Master Installer Code (100). Each User Code can be programmed to control specific functions and Partitions. Each Code must be assigned at least 1 Father code (up to 3 dif- ferent Father codes can be assigned). A Code can be assigned to itself, thus becom- ing its own Father code. Only the Father code can change the PIN, Available and Active status of its assigned Codes. PIN The PIN is the combination of digits that allows access to Code functions. The PIN can be a 4, 5 or 6 digit number. Keypads and User Codes Each Keypad and User code can be programmed to control specific Partitions. Therefore, the outcome of a command entered at a Keypad depends on the User code and Keypad in use (commands will affect ONLY the Partitions common to both the User Code and Keypad). This dual level of control greatly increases application flexibility, for example, a Code can be programmed to control a certain group of Partitions when entered at one Keypad, and a different group when entered at another. This fea- ture simplifies User control, as the same operation will have a different outcome on different Keypads. User Code Recognition Event Each time a Control panel recognizes a Valid Code, it will generate the Rec- ognized user code Event. Like all other Control Panel Events, this Event can be assigned to an Output or Telephone Action — regardless of whether or not the Code is enabled to request Control Panel actions. Therefore, an opportune combination of Events and Outputs will eliminate some of the hitches linked with access control and/or limitations. The Users page will allow you to program the Code at- tributes, as follows (the Installer Codes can be pro- grammed on the Installers page). The Code list (195 Codes for KYO 300; 97 Codes for KYO 100), on the left side of the Userspage, shows the following information for each Code. No. This non-editable field shows the Code ID Num- ber. Description This editable field (maximum 26 charac- ters) is for the Code label (e.g. User’s Name). The label will identify the User Code in all the operations it is in- volved in. The parameters of the Codes selected on the left side of the Users page can be programmed on right, as fol- lows. � You cannot change the attributes of a Code without first entering its Father code PIN. Available If this option is enabled, the corresponding Code can be programmed and used for system access. Many applications require fewer Codes. This option will allow you to enable only the required number of Codes, KYO 300-KYO100 PROGRAMMING 81 Figure 51 Users — Code access page

thus simplifying the programming process while in-

creasing the security level. Codes which have not been made Available can be considered inexistent. � NON-Available Codes will be assigned their de- fault PINs. � You cannot toggle the Available status of a Code, without first entering its Father code PIN. You cannot toggle the Available status of a Code when the Active option is Enabled. Active An Active Code can access and control the system in accordance with its access level. A Non-Active Code cannot access the system, how- ever, it can still be programmed using its Father Code. Father Codes can toggle the Active status of their as- signed Codes (also via the User Menu). � You cannot toggle the Active status of a Code that is the sole Father of another Code. AT Default: ONLY Code No. 001 is Active. Duress Code If this option is enabled, any Telephone actions (calls or reports) associated with the Recog- nized user code event (generated by the Code in question) will not be signalled on the keypad (i.e. <@255> will not appear over the i icon). Patrol Code If this option is enabled, the Code will be able to perform Disarm and Arm operations ONLY, re- gardless of its assigned Code Type. Furthermore, if a Partition is Disarmed by a Code with the Patrol attrib- ute, it will remain Disarmed for the programmed Pa- trol Time ONLY, after which, it will Rearm automati- cally (refer to “Patrol Time” under “Partitions”). Father Code 1 - 2 - 3 This drop-down list will allow you to select the Father codes. � Each Code can have up to 3 Father codes; � a Code can be programmed as its own Father. A Father Code can: � Change the PIN of its assigned Codes (Sons); � Enable/Disable the Active status of its assigned Codes, that is, if they are not Fathers of other Codes; � Enable/Disable the Available status of its assigned Codes. � YOU CANNOT assign a new Father code to a code without first entering the PIN of one of its cur- rent Father codes. For KYO 300 — Codes no. 132 to 195 (the 64 Tele- phone Access Codes) CANNOT be Father codes For KYO 100 — Codes no. 82 to 97 (the 16 Tele- phone Access Codes) CANNOT be Father codes. Father codes can be changed by the User. At default: � Code no. 001 is its own Father code; � Codes no. 002 to 131 (Codes no. 002 to 81 for KYO 100) have two Father codes: themselves and Code no. 001; � Codes no. 132 to 195 (Codes no. 82 to 97 for KYO 100) have one Father code: Code no. 001. � Enable on Partitions The Enable on Partitions Table will allow you to select the Partitions the Code will be able to control and set the A, B, C and D Arming modes, as follows. Partitions The Partitions line (first line) shows the Control Panel Partition ID Numbers. � If you click the Description button (at the bottom of the page), the application will show the Partition Description. The check boxes on the second line will allow you to se- lect the Code Partitions. � Box ticked: the Code CAN operate on the corre- sponding Partition. � Box empty: the Code CANNOT operate on the corre- sponding Partition. To DISABLE the Code on all the Partitions: click the Partitions button (bottom of page) then select None. To ENABLE the Code on all the Partitions: click the Par- titions button (bottom of page) then select All. To toggle the current Enabled/Disabled status of the Code: click Partitions button (bottom of page) then se- lect Invert selection. � Code commands will affect ONLY the Partitions (and subsequently the Zones) common to both the Code and Keypad in use. A This line will allow you to select the A Mode Arming configuration of the Partitions. Double click on the Partition field until the required mode is shown (D, N, A, S or I), or right click the Parti- tion field then select the required mode from the drop-down list. Arming Modes � D = Partition will Disarm � N = no operation � A = Partition will Arm in Away mode � S = Partition will Arm in Stay mode � I = Partition will Arm in Stay mode with zero delay (In- stant) B As forA but for B Mode Arm commands at a Keypad. C As forA but for C Mode Arm commands at a Keypad. D As forA but for D Mode Arm commands at a Keypad. � Associated Timer If a Code is associated with a Timer, it will function only during the programmed Timer slots (refer to “Scheduler - Timers”). 82

� User menu access

This section of the User page will allow you to limit the number of operations a code can perform (Arm, Arm Type A, B, c or D, Disarm and Access User Menu). Always If this option is enabled, the Code will be able to perform an UNLIMITED number of operations. If this option is disabled, you will be able to LIMIT the number of operations the Code will be able to perform via the Max. option. � ONLY Codes with Always status can be Father codes. You CANNOT disable the Always status of Fa- ther codes. A Code that DOES NOT HAVE Always status (Always option disabled) can be its own Father code, in which case, the Always attribute will be enabled automatically. Max. This field will allow you to program the number operations the Code will be allowed to perform. Valid entries: 1 through 254 The Code operation counter will count all the Arm, Arm Type A, B, c or D, Disarm and Access User Menu oper- ations. Once the Code reaches the Max. number of operations allowed, it will be automatically disabled. If an attempt is made to use a Code that has reached the Max. number of operations (therefore disabled), the display will show the [code not active] message. You must change the Code PIN, if you wish to refresh the Code operation counter. � ALL the Code operation counters will be refreshed automatically each time the User page is down- loaded. � Father PIN A Code’s Available status, Active status, Father codes and PIN cannot be changed without entering one of its programmed Father codes. � The Code PIN at default is 0 followed by the Code ID Number. Example: PIN of Code No. 001 is 0001. � New PIN This programming field will allow you to change the de- fault PIN, as follows: � enter the Code’s Father Code (to activate the New PIN programming field); � enter the New digits in the New PIN and Redigit New PIN fields, then click OK. The digits will be masked by asterisks (*). A PIN can have 4, 5 or 6 digits. WARNING: The default PINs of all Available Codes must be changed for security reasons. � You cannot change a Code’s Father code/s with- out first entering the PIN of one of its Father codes. Redigit New PIN Enter the digits of the New PIN in this field. If the entry is correct (both fields match), the PIN fields will clear when you click OK, and the New PIN will be- come Valid. In the event of mismatch, the PIN fields will not clear, and it will be necessary to repeat the procedure. � Code Type This parameter determines the Code functions — pro- grammed in the Code Types page (refer to “Keypad codes - Codes types”). � Enable on LCD Keypad The “Enable LCD keypad” table will allow you enable the code concerned on the LCD Keypads (16 keypads for KYO 100 and 32 for KYO 300). � Enable on LED Keypad The “Enable LED keypad” table will allow you enable the code concerned on the LED Keypads (16 keypads max). � Programming Due to the extreme importance of Code functions (sys- tem access and security), the programming procedure is different from that normally used. Full downloading of all the parameters on the User page depends on whether or not the Code PIN entries (entered at Computer) match the Control panel PINs (programmed at the system Keypad). In the event of mismatch, a dialogue box will inform you of the incon- gruity: <>. If you select OK you will be able to program the De- scription, Enabled Partitions, Associated Timers, User menu access and Code Type ONLY. If you wish to program the Code parameters (Available status, Active status, Panic attribute, Patrol attribute Father Codes and PIN), you must first upload the Users page from the Control panel. Matching Code entries All the programmed Code data will be downloaded, including any user modified parameters. Mismatching Code entries Only the following param- eters will be sent: � Description � Enabled Partitions Functions � Associated Timer � Code Type Codes - Installers The Installer Codes can access the system for pro- gramming and maintenance purposes. KYO 300-KYO100 PROGRAMMING 83

The MASTER Installer code is always Active and can

perform a limited number of programming and mainte- nance operations. The four Installer Codes (two for KYO 100) can be made Activated as required, and programmed to perform a lim- ited number of programming and maintenance opera- tions. � The Installer Code can program and change all pa- rameters via computer. The Installers page will allow you to program Installer code attributes, as follows. � You cannot program an Installer Code without first entering its Father Installer Code PIN. The Installer Code hierarchy is set at factory and CANNOT be changed: � Installer codes no. 196, 197, 198 and 199 (98 and 99 for KYO 100) have two Father codes which cannot be changed: themselves and Code no. 200 (no.100 for KYO 100); � Code no. 200 (no.100 for KYO 100) is its own Father code and cannot be changed. The Table on the left side of the Installers page shows the 5 Installer Codes (3 for KYO 100) . The page layout is as follows: No. Refer to “No.” in the “Keypad codes - Users” section. Description Refer to “Description” in the “Keypad codes - Users” section. On the right side of the Installers page you can set the parameters for the Codes selected on the left side of the page, as described below. Active Refer to “Active” in the “Keypad codes - Users” section. � The Active status of Installer Code no. 200 (Code no. 100 for KYO 100) is irreversible. Father PIN Refer to “Father PIN” in the “Keypad codes - Users” section. � At default the Installer Code PIN is 0 followed by the Code ID Number. For KYO 300 for example, the PIN of Code no. 200 is 0200; for KYO 100 the PIN of Code no. 100 is 0100. New PIN Refer to “New PIN” in the “Keypad codes - Users” section. Redigit New PIN Refer to “Redigit New PIN” in the “Keypad codes - Users” section. Code Type Refer to “Code Type” in the “Keypad codes - Users” section. � The Installer Code type CANNOT be changed. The Code Type for Installer Codes no. 196 and 197 (no. 98for KYO100) isInstall.Type1andCANNOTbechanged. The Code Type for Installer Codes no. 198 and 199 (no. 99forKYO100) isInstall.Type2andCANNOTbechanged. The Code Type for Installer Codes no. 200 (no. 100 for KYO 100) is a MASTER and CANNOT be changed. � Lost Installer Codes For the instructions on how to restore the default PIN 0200 for KYO 300, or 0100 for KYO 100, refer to the “Restore De- fault Settings” paragraph. ! If the Installer Codes Lock option is enabled (refer to “Options”), restoral of the default set- tings WILL NOT restore the Installer Code PIN. NOTE: If this occurs, contact your Service dealler. Codes - Code Types When programming the Codes, you must also select which functions are to be enabled. The system manages 19 Code Types: � 16 User Codes � 2 Installer Codes � Code Type 19 is reserved for Installer Code No. 200 (no. 100 for KYO 100), and CANNOT be pro- grammed. The Code Types page will allow you to select the User Code and Installer Code functions, as follows. On the left side of the Code Types page is a Table with a list of the 19 Code types. No. This is the Code Type ID Number: � Code Types no. 01 to 16 are reserved for User Codes; � Code Types no. 17 and 18 are reserved for Installer Codes; � Code Type no. 19 is reserved for Installer Code No. 200 (no. 100 for Kyo100) and CANNOT be pro- grammed. Description This editable field (16 characters) is for the label that will identify the Code Type. The label will be used in the Code Type on the Users and Installers pages. The functions of the Code Type (selected from the Code Type list) can be programmed on the right side of the page. The User Code functions are described in the following paragraph. The Installer Code functions are described in the “In- staller Codes” paragraph. 84

� User Codes

This paragraph provides a general description of the User Code functions — refer to the USER’S MANUAL for further information. � The Partition related functions will affect ONLY those Partitions common to both the Code and Keypad in use. Panel Reset This operation will: � terminate all the Control Panel Events (refer to Ta- ble 7 on page 64) and Generic Events (see Table 8 on page 65); � restore to standby any Outputs associated with the terminated events (refer to the previous points); � delete memory of BPI Device Tamper, Tamper Line Alarm, Control Panel Tamper, False Key and Super- vised Output Tamper events. � If the Alarm conditions are still present after Reset (approx. 2 seconds), the Control panel will trigger the relative Alarm Events again. Stop Alarms As per Panel Reset but for the Stop Alarms option. NOTE: If the Stop Alarms option is enabled, the events listed in the previous paragraph will be ignored. Arm/Disarm from User Menu If this option is en- abled, the Code will be able to Arm (in Stay/Away mode and Stay 0 Delay mode) and Disarm its Partitions, via the Arm option from the USER MENU. Request Overtime If this option is enabled, the Code will be able to make Overtime Requests for its Parti- tions. Request Teleservice If this option is enabled, the Code will be able to Enable/Disable Teleservice. Enab./Disab. Scheduler If this option is enabled, the Code will be able to Enable/Disable the Scheduler on its Partitions. Enab./Disab. Teleservice If this option is enabled, the Code will be able to Enable/Disable Teleservice. Enab./Disab. Answering Machine If this option is en- abled, the Code will be able to Enable/Disable An- swering facility. Enab./Disab. Keypad Buzzer If this option is en- abled, the Code will be able to Enable/Disable the Key- pad buzzer. Phone Number Modify If this option is enabled, the Code will be able to edit the Telephone Numbers in the General Phonebook. Date/time Modify If this option is enabled, the Code will be able to set the Control Panel date and time. Reset Warning PC Progr. If this option is enabled, the Code will be able to restore fault signals triggered by computer or Keypad programming. Keypad Test If this option is enabled, the Code will be able to run the Keypad test. Squawk If this option is enabled, the Code will be able to run the test on Output no. 1. Output ON/OFF If this option is enabled, the Code will be able to switch the Reserved Outputs ON and OFF. Bypass/Unbypass Zones If this option is enabled, the Code will be able to Bypass/Unbypass and view the sta- tus of the Zones of its Partitions. Reset/Play/Restart Continuous Rec. If this option is enabled, the Code will be able to manage the Continu- ous Recording facility. KYO 300-KYO100 PROGRAMMING 85 Figure 52 Codes Type page

Play/Rec. Memo If this option is enabled, the Code will

be able to listen to and record Voice Memos at the Key- pad. View Logger If this option is enabled, the Code will be able to view and print the Events — relative to its Parti- tions — in the Control panel Logger. � This feature is provided by the optional K3-PRT Printer Interface (refer to “K3-PRT Printer Inter- face” in the APPENDIX). Only Enabled events can be printed (refer to “Log- ger — Event settings”). Clear Call Queue If this option is enabled, the Code will be able to stop outgoing calls. Enable Timer Control If this option is enabled, the Code will be able to program specific Timers (refer to “Controlled Timers”) via the USER MENU. If this option is disabled, the Timers can be selected in the “Con- trolled Timers” section. Enable Key Control If this option is enabled, the Code will be able to enable/disable any Keys which op- erate on the Partitions it is assigned to. Each Enable/Disable Key operation, complete with the Code and Keypad concerned, will be recorded in the event logger. The Maximum Operations’ counters of ‘limited’ Keys (i.e. Keys programmed with a maximum number of operations) will refresh automatically when the Key is deactivated. Enable Timers Control If this option is enabled, the Code will be able to Enable/Disable the Timers selected in the ‘Controllable Timers’ section. Clear phone queue on Partition in stop/reset If this option is enabled, outgoing calls — triggered by events associated with the Code Partitions — will be aborted when the Code is used to stop/reset Alarms. Clear phone queue on Panel in stop/reset If this option is enabled, outgoing calls — triggered by events associated with the Control panel — will be aborted when the Code is used to stop/reset Alarms (refer to the Table 7 on page 64). Clear phone queue on disarming If this option is en- abled, outgoing calls — triggered by events associated with the Code Partitions — will be aborted when the Code is used to Disarm the system. Reset Partition Alarms If this option is enabled, Resets Partition Alarm operations requested by the Codes will: � terminate all Partition Events (refer to Table 6 on page 63) and Zone Events (refer to Table 5 on page 62) associated with the Code Partitions; � restore to standby the Outputs associated with the terminated events (refer to the previous points); � delete Generic Partitions and Partitions Tamper Alarms generated by the Code Partitions. � If the Alarm conditions are still present after Reset (approx. 2 seconds), the Control panel will trigger the respective Alarm Events again. Stop Partition Alarms As for Reset Partition Alarms but for the Stop Alarms option. NOTE: If this option is enabled, the events listed in the previous paragraph will be ignored. Arming A with User Code If this option is enabled, the Code will be able to perform A Mode Arming operations. Arming B with User Code If this option is enabled, the Code will be able to perform B Mode Arming operations. Arming C with User Code If this option is enabled, the Code will be able to perform C Mode Arming opera- tions. Arming D with User Code If this option is enabled, the Code will be able to perform D Mode Arming opera- tions. Away Arming with User Code If this option is en- abled, the Code will be able to Arm all the Partitions com- mon to both the Code and Keypad in use in Away mode. Disarming with User Code If this option is enabled, the Code will be able to Disarm all the Partitions com- mon to both the Code and Keypad in use. � Installer Codes This paragraph provides a general description of the func- tions that can be performed by the Installer Codes: refer to the KEYPAD PROGRAMMING MANUAL for details. View logger If this option is enabled, the Code will be able to view and print the events recorded in the Log- ger. � This feature is provided by the optional K3-PRT Printer Interface (refer to “Printer Interface” in the APPENDIX). Only the enabled events will be printed (refer to “Logger — Events setup”). Zone Status If this option is enabled, the Code will be able to view the status (Standby, Alarm, Short, Tamper, Bypass) of all the Control Panel Zones, and the per- centage of the Voltage value. Zone Test If this option is enabled, the Code will be able to Test all the Control Panel Zones. Output Test If this option is enabled, the Code will be able to Stop all the Control Panel Outputs. Clear Call Queue If this option is enabled, the Code will be able to clear the Call Queue. Voice Functions If this option is enabled, the Code will be able to record and listen to Voice Messages. 86

Change Installer PIN If this option is enabled, the

Code will be able to change its own PIN, and the PINs of its assigned codes (sons). User Codes If this option is enabled, the Code will be able to program the User codes from the Keypad. Digital Keys If this option is enabled, the Code will be able to the Digital Keys from the Keypad. Panel Programming If this option is enabled, the Code will be able to program the Control Panel from the Keypad. Enrol Wireless If this option is enabled, the Code will be able to enrol Wireless Devices from the Keypad. Keypad Broadcast If this option is enabled, the Code will be able to edit the Keypad strings. Change date/time If this option is enabled, the Code will be able to change the system Date and Time from the Keypad. Digital keys The Digital Keys page will allow you to program the pa- rameters of the Digital Keys, as follows. � Digital Keys can be enrolled at the Keypad (refer to the KEYPAD PROGRAMMING Manual. The Table on the left side of the Digital Keys page shows the Keys the Control Panel can manage. � Select the required Keys: Box checked (�) = Key Enabled Box empty = Key Disabled Press the Select button at the bottom of the page to En- able/Disable all the Keys. � The system will consider Disabled Keys as False, even if they have been enrolled. No. This is the Key ID Number. Description This editable field (16 characters) is for the Key label (e.g. User’s Name). The label will identify the key in all the operations it is involved in. The parameters of the key (selected on the left side of the page) can be programmed on the right side of the Keys page, as follows. Enable on Partitions This line will allow you to assign the Key to the Partitions. Box checked (�) = the Key is Enabled on the corre- sponding Partition Box empty = the Key is Disabled on the corresponding Partition To DISABLE the Key on all the Partitions: click the Par- titions button (bottom of page) then select None. To ENABLE the Key on all the Partitions: click the Partitions button (bottom of page) then select All. To toggle the current Enabled/Disabled status of the Key: click Partitions button (bottom of page) then se- lect Invert selection. Stop Alarms If this option is enabled, the Key will be able to stop Control panel Alarms (refer to “Stop Alarms” under “Codes - Code types”). Stop Partition Alarms If this option is enabled, the Key will be able to stop Partition Alarms (refer to “Stop Alarms” under “Codes - Code types”). Clear Call Queue on disarming If this option is en- abled, the Key will be able to stop outgoing Alarm calls (refer to “Clear Call Queue upon Disarming” under “Codes - Code types”). Associated Timer If this option is enabled, the Key will be able to perform its programmed functions ONLY dur- ing its Timer slots (refer to “Scheduler - Timers”). � Allowed Operations This section of the Digital Keys Page will allow you to set up the amount of times a Key can operate the sys- tem (i.e. perform Arm/Disarm in Away, A and B Mode operations) before it is locked out automatically. Unlimited If this option is enabled, the Key will be able to perform an unlimited number of operations. If this op- tion is disabled, the required number of operations can be programmed in the Operations field. Maximum Operations This programming field will al- low you to program the amount of times the Key can op- erate the system (accepted values: 1 to 254). The system will disable the Key automatically when the ‘Maximum Operations’ counter reaches its limit. The ‘Maximum Operations’ counter can be cleared and the Key re-enabled by entering a valid User Code (refer to “Enable Key Control” under “User Code Type”). � Attributes Patrol If this attribute is enabled, the Key will be able to Disarm and Re-arm the Control panel during the pro- grammed Patrol Time. If a Partition is disarmed by a Key with the Patrol attribute, the Partition will Re-arm automatically when the programmed Patrol time of the Partition concerned expires (refer to “Patrol Time” in the “Partitions” section). � Enable on Key Reader The “Enable Key Reader” table will allow you enable the code concerned on the Key Reader (16 Readers for Kyo100 and 32 for Kyo300). KYO 300-KYO100 PROGRAMMING 87

Proper functioning of the Scheduler/Timers depends on

the Clock setting (Clock page), therefore, the Control panel clock must be set with extreme precision. Actual Date Set the current date. Actual Time Set the current time. Date format Select the Keypad date format: � dd/mm/yyyy = day/month/year � mm/dd/yyyy = month/day/year � yyyy/mm/dd = year/ month/day On-site downloading Once the operating parameters have been set up, they must be downloaded to the relevant Control Panel, as follows. � Access to Programming requires the Installer Code PIN. 1. Connect the Control Panel serial port (24) to one of the PC serial ports, as follows: – using a CVSER/9F9F link (accessory item), or a cable similar to the one in Figure 53a, connect the Control Panel to the PC; – if the PC serial port has 25 pins, use an ADSER/9M25F adapter (accessory item), or a ca- ble similar to the one in Figure 53b. 2. Select the PC serial port used for connection with the Control panel, as follows: – select Serial Ports from the Settings menu; – select the serial port (Control Panel section); – select the number of attempts (Attempts box) and Baud Rate; – click Download (Baud Rate section) or OK. 88 5 4 6 5 4 3 2 1 9 18 8 19 17 16 15 14 7 20 21 22 23 24 25 6 3 7 2 8 9 10 11 12 13 1 DB9 female connector a) b) 7-wire cable shield DB25 female connector 5 5 4 4 9 9 8 8 7 7 6 6 3 3 2 2 1 1 DB9 female connector 7-wire cable shield DB9 female connector Figure 53 Wiring diagram for the serial link between the Control panel and PC

Select the parameters to be downloaded, as fol-

lows: – select Parameters from the Settings menu; – enter a valid Installer code in the Installer code field; –select the Control panel type from the Panel type menu; –select the relevant firmware release from the Firmware Release menu; – click OK. 4. To download a specific page: click the Download button on the page in question. 5. To Download several pages: – select the required page from the Folders menu, right click, select Tag (a � on the page Icon indi- cates that it will be downloaded); – repeat the procedure for all the required Pages; – right click again then select Download. � To download a family of pages, select the root. ! If you send the User page with other pages, the Control panel WILL STORE the Description, En- abled Partitions, Associated Timers, User Menu Access and Code type parameters, but WILL NOT STORE the Available status, Active status, Duress Code, Patrol Code and Father Code parameters. � If changes to the Descriptions are not shown on the Keypads, use the Broadcast Keyp.command from the INSTALLER MENU. For example: – to download all the Configuration re- lated pages, select Configuration from the Folders menu; to download All the Pages, select KYO 300 (or KYO 100) from the Folders menu. 6. To view the parameters of the connected Control Panel, work carefully through point 4. then select Upload instead of Download. Remote Downloading You can download the programming data via telephone line, using a B-Mod or B-Mod/RX modem, as follows. � Telephone access requires entry of the Installer code PIN, and will ONLY be allowed when the Teleservice option has been Enabled by the User (refer “En- able/Disable Teleservice” in the USER’S MANUAL). 1. Using the serial cable (the same as used for On-site Down- loading),connecttheModemtooneofthePCserialports. 2. Select the PC serial port for connection with the Modem, as follows: – select Serial Ports from the Settings menu; – select the serial port (Modem section); – select OK. 3. Select Connecting from the Modem menu: this command will open the Connecting window (see Figure 54). 4. Program the following parameters: – Telephone Number – enter the Control panel telephone number; – Disable Tone Check – Enable/Disable this op- tion as required. If this option is Enabled, the Modem will not check for the dialling tone before dialling; – Double call – refer to the Teleservice page; – Call back – refer to the Teleservice page; – Installer Code – enter a valid Installer code PIN (enabled for Downloading) When the Connecting window opens, the above pa- rameters (except for Disable Tone Check) will have the programmed settings. � The parameters in the Connecting window can be changed temporarily without affecting the pro- grammed parameters of the open Customer. 5. Press Dial: the connection status will be shown in the box at the bottom of the Connecting window (refer to “Messages”). If the connection is com- pleted properly, the following message will be shown: KYO 300 ACK 01.00 CONNECTION 6. Select OK: the Connecting window will close. At this point, it will possible to download/upload to/from the connected Control panel. 7. To program and view the parameters of the con- nected Control panel, work carefully through steps 4. and 5. in the “On-site Downloading” section. 8. Select On-hook from the Modem menu to end the connection. Messages The connection status will be shown in the box at the bottom of the Connecting window, as follows. KYO 300-KYO100 PROGRAMMING 89 Figure 54 Connecting Window

MODEM v. x.xx This is the release of the Modem that

is connected to the PC serial port Modem not recognized The application cannot find the Bmod on the specified serial port. Check the cable and serial port settings Receiving... The Modem/PC system is waiting for an incoming call. This is the status when the Connections window opens RING The modem detects rings on the telephone line BUSY The dialled number is busy BACKRING the dialled number is ringing KYO 300 ACK A KYO300 Control Panel has been recognized 1.20 This is the Firmware Release of the Control panel CONNECTION The Modem and Control Panel are connected ON HOOK The Modem has released the line Installer Code reading error The Control panel cannot read the PIN — probably due to a poor quality signal on the telephone line Lost Connection It is impossible to communicate with the Control Panel — probably due to a poor quality signal on the telephone line 90 LED MIC +12 SPK+ EXT.SP EN.MIC RST.MSG 112 113 114 115 116 117 Figure 55 Voice board components

K3-VOX Voice Board

! Disconnect the Mains and battery power before starting the installation procedure. The K3-VOX Voice board records and plays Voice messages. The recorded voice messages can be as- signed to the: � Status enquiry � Answer message � Dialler messages � Memo � Continuous recording � Features � Messages stored on ChipCorder � Manages up to 62 Voice messages with programma- ble sound quality and duration — varying from 2 min- utes 8 seconds of high sound quality to 8 minutes 33 seconds of low sound quality � Speaker for Message playback � Telephone-dialler � Answerphone � Telephone access � Listen-in and remote 2way Speaker system (Teleassistance) � Identification of Parts No. DESCRIPTION 112 Save Message Jumper: oo= if power to the Voice board fails, the recorded messages will be deleted (at default); //= if power to the Voice board fails, the recorded messages will be stored for at least 2 hours 113 Main Unit Voice board connector 114 Microphone 115 Local Microphone Jumper (114): // = Local Microphone enabled (at default) oo = Local Microphone disabled 116 Speaker Connector 117 Terminal board (for Microphone board connec- tion) (VOX-REM) � Installation Work carefully through the following steps (see Fig- ure 55 and Figure 3 on page 11). 1. Insert the Speaker into one part of the plastic holder. 2. Join the two parts then twist to lock in place. 3. Screw the Speaker onto the backplate. 4. Plug the Voice board into the connector 17, secure it firmly in position by means of the screws. 5. Plug the Speaker into the connector 116 on the Voice board. 6. Insert the jumper 112 (to store recorded messages during blackout). � Expanding the Listen-in facility You can expand Listen-in coverage by connecting sev- eral Microphone-Speaker boards to the Voice board. This is especially useful for large premises, or in places where there is a high risk of sound muffling caused by walls or heavy machinery, etc. � In the text and diagrams in this section, the term “Voice Module” refers to VOX-REM Microphone-Loudspeaker board and the Alison-DV Keypad. The VOX-REM Microphone-Speaker board can be housed in custom made accessory boxes with wire en- try knockouts (order code: MINI-BOX). The MINI-BOX can be wall mounted, or flush mounted to 503 outlet boxes or similar. The installation instructions can be found in the MINI-BOX package. � The Microphone and Loudspeaker should be housed in separate boxes. “Voice Modules” should be mounted in places which allow easy access. DO NOT mount VOX-REM Microphone-Speaker boards until you have tested the placements for squealing. Connect the “Voice Modules” in parallel to the Voice board, as shown in Figure 56. The number of “Voice Modules”, and the connection lengths can affect sound quality, therefore: � DO NOT connect more than 4 “Voice Modules” to the Voice board. � DO NOT use more than 50 metres of cable between each “Voice Modules” and the Voice board. KYO 300-KYO100 APPENDIX 91

! Terminals [M], [SP+], [SP-] and [MIC], on the

Alison-DV, must be connected to the Voice Board by a separate cable to the one used for the connection of terminals [+], [C], [R] and [-] to the Control panel BPI Bus. � In order to improve message quality, use the Voice Board Microphone, and temporarily disconnect the other “Voice Modules”. All “Voice Modules” will be interconnected during Teleassistance mode thus allowing users to communi- cate with one another. � Manual selection Installation of several “Voice Modules” will allow the user to listen-in on the various parts of the premises at the same time, however, sound tracing will not be possible. For sound tracing—complete the connections, as shown in Figure 57. The wiring diagram shows the Voice board and 4 “Voice Modules”, and also: � a 6-Output expander M-OUT/6 � a 6-Input expander M-IN/6 � two Omnia/4R Relay modules The Control panel must be programmed as follows: � all the Expander Outputs must be Reserved (man- ual), Bistable and Normally Open. � the Input expander zones must be: Instant, Repeti- tive and Normally Open (DO NOT assign these to Partitions). The zones must be associated with a Standby Voice message that identifies the location of the zones (e.g. Kitchen, Sitting room, etc.). Enable Remote Listen-in via Telephone 1. Press 3 (to access Outputs Management). 2. Press 1 (to select ON), then enter the number (3 digits) of the required “Voice Module” Output. 3. Press 1 (to start the Remote Listen-in session). For example, if the Output-expander is assigned to Ad- dress no. 01, its hardware Outputs OC1, OC2, OC3 and OC4 will correspond to software Outputs 7, 8, 9 and 10. Therefore, to activate the first “Voice Module” (connected to hardware Output OC1 — software Output no. 7) en- ter: 310071 (3 to access Outputs Management; 1 to se- lect O; 007 to select Output no. 7; and 1 to start the Listen-in session). 4. To Listen-in on other parts of the premises during the same call: press # (to stop the active “Voice Mod- ule”.); 3 (to access Outputs Management); 0(to se- lect OFF); enter the Identifier number of the active “Voice Module” Output (3 digits — 007 in the exam- ple), then repeat steps 1 through 3. � Auto-select mode The Auto-select mode will allow the Control panel to se- lect the nearest “Voice Module” to the zone in alarm. Figure 57 shows the necessary wiring. The Outputs and Event-Actions must be programmed, as follows. Software Outputs 7, 8, 9and 10 (available for this appli- cation) must be: Monostable and Normally open (DO NOT program these Outputs as Reserved). The ON Time of the Output determines how long the “Voice Module” will stay ON after activation, therefore, must be long enough to allow the User to Listen-in on the location. Each Output, connected as shown in the wiring diagram (Figure 57) will be able to control one “Voice Module”. Use the Partition and/or Control panel Events in the Event-Actions page to activate the Dialler and Tele- phone Communicator Outputs. In this way, the zone events will be available for “Voice Module” manage- ment. Program the zone events (relevant to the loca- tion in question) to activate the Output that controls the respective “Voice Module”. Repeat this procedure for the other Outputs, as required. Auto-select mode will allow the User (during a dialler call) to activate Remote listen-in on the location that generated the Alarm. 92 SPK+ SP+ SP+ SP+ SP+ SPK- SP- SP- SP- SP- MIC MIC MIC MIC MIC Voice board VOX-REM Alison-DV VOX-REM Alison-DV +12 Figure 56 Connection of a VOX-REM Microphone Board and 2 Alison-DV Keypads to the Voice Board

� Manual and Auto-select mode

Manual and Auto-select Listen-in can be integrated. This will allow the User to select (manually) specific lo- cations during standby status. Use 4 Outputs for Manual-select Listen-in mode, and 4 Outputs for Auto-select listen-in mode. The Outputs must be connected in two’s — one Manual and one Auto, as shown in Figure 57. To ensure proper functioning of Auto-select mode, the man- ually controlled Outputs must be in standby status. There- fore, the Outputs must always be restored to Standby when a manually controlled listen-in session ends. K3-PRT Printer Interface ! Disconnect the Mains and battery power before starting the installation procedure. The optional K3-PRT Printer Interface will allow you to connect the Control panel to a parallel printer for: — Real-time printout of events (refer to “Accessories” under “Configuration” in the Programming” section); — Entire Logger printout (refer to “Print Logger” under “Keypad Codes – User” in the Programming” section and/or “Event Logger” under “Operating your system from a Keypad” in the USER MANUAL); — Specific events printout (refer to “ Logger — Events Setup” under “Programming”). � Identification of Parts The following Table describes the parts illustrated in Figure 58. The numbers in boldface in this section, refer to parts in Figure 58 (unless otherwise specified). No. DESCRIPTION 118 Interface connector 119 Printer connector � Connecting the Printer If you prefer to chase the lead, use a plug-free cable (re- fer to Table 12 for the wiring specifications and see also Figure 59). Moulded plug leads (usually supplied with the printer) cannot be chased. � Installation instructions Work carefully through the following steps (see Fig- ure 58 and Figure 3 on page 11). 1. Lay the cable between the printer and the Control panel. 2. Plug the Printer interface into the connector 15 on the Control panel PCB then, using the screws, se- cure it in place. KYO 300-KYO100 APPENDIX 93 SPK+ SP+ SP+ SP+ SP+ SPK- RL1 RL1 SP- SP- SP- SP- MIC RL2 OC2 OC2 OC2 L2 OC4 OC4 OC4 L4 OC3 OC3 OC3 L3 OC1 OC1 OC1 L1 RL2 RL3 +12 +F +12 RL3 RL2 RL2 MIC MIC MIC MIC Voice board Output exp. 01 Input exp. 01 Omnia/4R Omnia/4R 1 Voice module st 2 nd Voice module 3 Voice module rd 4 Voice module th +12 * * * * Connect ONLY the [+] terminals of the board to the terminal [+12] of the Voice Board. The [+] terminals of Keypads must be connected to the [+] terminal of the Control panel. VOX-REM Alison-DV * Figure 57 Wiring for Manual-select Listen-in mode

Connect the Printer lead to the connector 119 on

the Printer Interface. K3-AuxCom Auxiliary Communicator ! Disconnect the Mains and battery power before starting the installation procedure. The K3-AuxCom Auxiliary Communicator (accessory item for KYO 300 only) supports the most widely used reporting formats. It manages up to 8 Telephone numbers. Each of which can be associated with a different User and Event Code. The K3-AuxCom will trigger the programmed event calls when the Control panel Microprocessor blocks. � Installation Please read this section to get an overall view of the steps involved in installing the K3-AuxCom Auxiliary Communicator (see Figure 3 page 11). 1. Insert the K3-AuxCom into the Auxiliary Communi- cator connector 19 on the Control panel PCB then, Using the screws, secure it firmly in position. 2. Remove the jumpers 18 and 48 to enable the Auxil- iary Communicator. � The K3-AuxCom cannot function when jumpers 18 and 48 are inserted. If you disconnect the K3-AuxCom, you must RE-INSERT jumpers 18 and 48, otherwise, the Con- trol panel will be isolated from the Telephone line. VectorRX Receiver The VectorRX Receiver (accessory item) will allow your sys- tem to manage up to 32 Wireless detectors (PIRs, Magnetic Contacts, Smoke detectors), and up to 16 Wireless keys. Please read this section to get an overall view of the steps involved in installing the VectorRX Receiver. � Identification of Parts The following Table describes the components of the VectorRX Receiver (see Figure 60). The numbers in boldface in this section, refer to the descriptions in the Table and Figure. No. DESCRIPTION 120 Spring catch slots (2) 121 Anchor screw locations (3 x ø 4.6 mm) 122 Antennas (2) 123 Microprocessors (2) 124 Snatch Microswitch 125 Tamper button 126 Screws (2) 127 Wire entry (10 x 6.4 mm) 94 118 119 Figure 58 Printer Interface components 18 20 21 22 23 24 25 Printer side: Centronics connector, male: pins from 15 to 17 and 19 through 30 must be connected together and to pin 19 of the DB25 connector 18 wire shielded cable : the shield must be soldered to the metallic casing of both connectors (max. length 10 m) Interface side: DB25 connector male 13 12 11 10 9 8 7 6 5 4 3 2 1 14 15 16 17 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 15 18 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 Figure 59 Wiring diagram of parallel printer cable Interface connector: DB25 connector, male 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 wire cable + shield: the shield must be soldered to the metal casing of both connectors 1 2 3 4 5 6 7 8 9 10 11 12 13 14 32 31 36 15÷17/19÷30 Printer side: Centronics connector, 36 pin, male Table 12 Wiring diagram of the cable between the parallel printer and the Printer Interface

128 Spring Catch

129 Terminal board � Choosing a Mounting Location � Mount the Receiver and Wireless Devices after the placement tests. Choose a place that is: � Dry � Central to the proposed placement of all Wireless Devices � As close to the ceiling as possible � Far from sources of interference such as: electrical noise (computers, televisions, electric motors in ap- pliances, and heating and air-conditioning units), and large metal objects (heating ducts and plumbing) which may shield the antennas. Ensure that no electrical wires run over the Receiver antennas. When mounting in a basement, place the module as high and as close to the underside of the first floor as possible. The range of the Receiver will be re- duced if the unit is mounted below ground level. � Mounting the Receiver When choosing the mounting location ensure that the mounting surface is flat, as uneven surfaces may impair proper functioning of the snatch switch 20. Read the following instructions carefully before mount- ing the Receiver (refer to the Figure 60). 1. Loosen the screws 22 (it is not necessary to re- move them). 2. Press down on the tab 24 to release the backplate from the frontplate. 3. Lift the frontplate upwards to a 90° angle, then pull the frontplate away from the backplate. 4. Pull the connection wires through the wire entry 23. 5. Place the backplate in the proposed placement, mark the screw positions 17 then drill the screw holes. ! Be careful to avoid conduits and plumbing when drilling. 6. Place the backplate in the proposed placement, pull the wires through the wire entry 23, then secure the backplate to the wall (use anchor screws). 7. Complete the connections on the terminal board 25 (refer to “Connecting the Receiver”). 8. Push the frontplate spring catches into the slots on the backplate then push the bottom of the frontplate into place. 9. Fasten the screws 22. � Connecting the Receiver Connect the Receiver terminal 25 to the Interface termi- nal 15 (as shown in Figure 61). � Use Shielded cable for the connection: connect one end of the shield to terminal BLK on the Inter- face, and leave the other end free. Do not use more than 50 metres total wire length. � Technical Specifications The following table contains the technical Specifica- tions of the VectorRX Receiver. Voltage 13.8 V_ Current draw 50 mA Frequency 433 MHz Dimensions (W x H x D) 146 x 290 x 28 mm Weight 483 g Reset default To reset the factory default programming: KYO 300-KYO100 APPENDIX 95 NO WIRING IN THIS AREA RED BLK YEL GRN GND11 ATN1 GND1 ATN1 GND22 GND2 ® 121 125 124 123 123 122 129 121 120 120 121 126 127 128 126 122 Figure 60 The Receiver components

Remove all power from the Control panel (Mains

and battery). 2. Remove the jumper 21 (M). 3. Wait at least 20 seconds. 4. Replace the jumper 21 (M). 5. Restore power to the Control panel (refer to “Con- necting the Power Supply” under “INSTALLING THE KYO300”). ! Jumper 21 (M) must be disconnected for at least 20 seconds in order to ensure full reset of the factory default programming, and to avoid problems that may occur when the power sup- ply is restored. Installer code locked If the Lock Installer code op- tion is enabled, the Installer PIN will not be able to reset to factory default (refer to Lock Installer code in the Op- tions section). Reporting Formats This paragraph describes the structures of the main re- porting formats supported by the system. � TELIM The TELIM protocol transmits as follows: � User Code (4 digits — 0 through 9); � Event Code: 41 in the event of Alarm or Tamper on the first 16 zones of the Control panel, 0 in all other cases; � 2 byte (16 bit) representing the status of the first 16 zones — 0 Standby; 1 = Alarm or Tamper. � Contact ID Contact ID transmits as follows: � User Code (4 hexadecimal digits — 0 through F ); � Qualifier: 1 = new event or Disarming operation; 3 event restore event or Arming operation � Class Code (CL. column): identifies the type of event (Alarm, Trouble, Fire, etc.); � Event Code (CODE column): identifies the event (Event Codes can be changed, refer to “Actions” un- der “Digital Communicator” in the “PROGRAMMING” section); � Group Number (GROUP column), where possible, identifies the Partition of the “object” which gener- ated the event; � Zone Number (ZONE column), where possible, identifies the “object” (Zone, Code, Key, etc.) which generated the event. � SIA SIA is a FSK (Frequency Shift Keying) format, that transmits alternatively in two slightly different frequen- cies. The frequency shift is usually 170 Hertz, and the two frequencies are associated with 0 and 1 of the bi- nary digit which transmits the following data: � User Code (4 digits — 0 through 9) � Function Code (1 digit; N=new event, O=restore event) � Date (month-day-year) � Time (hour-minutes-seconds) � Event Type (refer to the TYPE column in Table 13) � Event Agent (refer to the 1st and 2nd columns in Ta- ble 13). New features This section describes the new features of the Up- graded KYO300. � The Control panel release can be read on the Mi- croprocessor (see Part no. 39 on page 11), or on any of the system Keypads, by means of the Re- lease option from the INSTALLER MENU. � KYO300 1.10 Enable/Disable Timer 78, 86 This feature allows User Codes to enable/disable the Timers. Turn ON/OFF Timers 78 This feature allows the Control panel to record all Timer operations (ON/OFF) in the Event Logger. 96 Receiver GRN RED Panel YEL BLK GRN RED YEL BLK Figure 61 Connecting the receiver to the Control panel

16 character labels can be assigned to each Timer.

Power Station Management 7, 19, 34, 66, 98 The Control panel Bus accepts up to 8 x 2 A and/or 5 A Power Stations. Duress Code 82 This attribute allows User Codes to generate call and/or report transmission associated events, without generat- ing audible or visual signalling on Keypads. Patrol Code 48, 82 This attribute allows User Codes to Disarm Partitions for the programmed Patrol Time, and Rearm them be- fore the programmed Patrol Time expires. User menu access 83 This feature allows User Codes to carry out an unlim- ited/limited number of operations. Autoreset on Arming 48 This feature allows Partitions to Reset automatically each time they Arm. Customized Events 64, 65 This feature allows the system to manage up to 32 Cus- tomized events. Each Customized Event will be gener- ated by the combined effect of two other events (selected as required) that must occur within a pro- grammed interval (window). The Operator (AND, OR or XOR) of the two selected Events will determine the op- erating mode of the Customized Event. This feature is particularly useful in commercial buildings where, for security reasons, two Codes must be entered within a 2 minute window, to open a safe-room door. Full Arming Alarm 41, 44 This feature allows Zones to generate Alarms when AT LEAST ONE of their associated Partitions is Armed. Auto-arm on delay 40 This feature allows Zones to Arm their associated Parti- tions automatically. If a Zone DOES NOT DETECT mo- tion within a programmed interval, the system will assume that no Users are present and will Arm the Par- titions the Zone belongs to. KYO 300-KYO100 APPENDIX 97 EVENT CONTACT ID SIA CL. CODE GROUP ZONE TYPE 1st 2nd Alarm on zone 1 30 00 zone no. BA/BR 0000 zone no. Tamper on zone 1 37 00 zone no. TA/TR 0000 zone no. Fire alarm on partition 1 10 part. no. 000 FA/FR part. no. 000 24h alarm on partition 1 33 part. no. 000 BA/BR part. no. 000 Burglar alarm on partition 1 30 part. no. 000 BA/BR part. no. 000 Generic alarm on partition 1 30 part. no. 000 BA/BR part. no. 000 Tamper alarm on partition 1 37 part. no. 000 TA/TR part. no. 000 Generic+Tamper alarm on partition 1 37 part. no. 000 TA/TR part. no. 000 Away alarm on partition 1 30 part. no. 000 BA/BR part. no. 000 Stay alarm on partition 1 30 part. no. 000 BA/BR part. no. 000 Fire alarm on panel 1 10 00 000 FA/FR 0000 000 24h alarm on panel 1 33 00 000 BA/BR 0000 000 Burglar alarm on panel 1 30 00 000 BA/BR 0000 000 Generic alarm on panel 1 30 00 000 BA/BR 0000 000 Tamper alarm on panel 1 37 00 000 TA/TR 0000 000 Generic+Tamper alarm on panel 1 37 00 000 TA/TR 0000 000 Tamper on Main unit 1 37 00 000 TA/TR 0000 000 Stop-alarms jumper 3 00 00 000 RO/RC 0000 000 Balanced tamper 1 37 00 000 TA/TR 0000 000 Tamper on supervised output 3 24 00 000 YA/YH 0000 000 Tamper BPI readers 3 41 00 000 ET/ER 0000 000 Tamper BPI input expanders 3 41 00 000 ET/ER 0000 000 Tamper on keypads 3 41 00 000 ET/ER 0000 000 Tamper output expanders 3 41 00 000 ET/ER 0000 000 Tamper power stations 3 41 00 000 ET/ER 0000 000 Tamper wireless device 3 41 00 000 ET/ER 0000 000 Warning readers 3 33 00 000 ET/ER 0000 000 Table 13 Structure of the main Reporting formats supported by the System (continued ...)

CL. CODE GROUP

ZONE TYPE 1st 2nd Warning BPI input expander 3 33 00 000 ET/ER 0000 000 Warning keypads 3 33 00 000 ET/ER 0000 000 Warning output expanders 3 33 00 000 ET/ER 0000 000 Warning power stations 3 33 00 000 ET/ER 0000 000 Warning wireless device 3 33 00 000 ET/ER 0000 000 False key 4 21 00 000 DD/DR 0000 000 Warning fuse +F 3 00 00 000 YP/YQ 0000 000 Warning fuse +F1 3 00 00 000 YP/YQ 0000 000 Warning fuse +B1 3 00 00 000 YP/YQ 0000 000 Warning fuse +B2 3 00 00 000 YP/YQ 0000 000 Warning fuse +B3 3 00 00 000 YP/YQ 0000 000 Warning fuse +B4 3 00 00 000 YP/YQ 0000 000 Warning fuse +B5 3 00 00 000 YP/YQ 0000 000 Warning fuse BPI1 3 00 00 000 YP/YQ 0000 000 Warning fuse BPI2 3 00 00 000 YP/YQ 0000 000 Warning fuse KEYBUS 3 00 00 000 YP/YQ 0000 000 Warning mains failure 3 01 00 000 AT/AR 0000 000 Warning low battery 3 02 00 000 YT/YR 0000 000 Warning power trouble 3 00 00 000 YM/YR 0000 000 Warning mains failure on Power station 3 01 00 000 AT/AR 0000 000 Warning low battery on Power station 3 02 00 000 YT/YR 0000 000 Warning power trouble on Power station 3 03 00 000 YM/YR 0000 000 Battery not connected on Power station 3 00 00 000 YP/YQ 0000 000 Battery charger trouble on Power station 3 00 00 000 YP/YQ 0000 000 Switching not connected on Power station 3 00 00 000 YP/YQ 0000 000 Short circuit output ½/3 on Power station 3 00 00 000 YP/YQ 0000 000 Battery low memory 3 07 00 000 YT/YR 0000 000 Warning low battery on wireless device 3 38 00 000 XT/XR 0000 000 Memory tamper BPI device 3 41 00 000 ET/ER 0000 000 Memory balanced tamper 1 37 00 000 TA/TR 0000 000 Memory tamper on main unit 1 37 00 000 TA/TR 0000 000 Memory false key 4 21 00 000 DD/DR 0000 000 Memory tamper supervised output 3 21 00 000 YA/YR 0000 000 Trouble auxiliary communicator (VDS) 3 33 00 000 ET/ER 0000 000 Lost wireless zone 3 33 00 000 ET/ER 0000 000 Warning generic 3 00 00 000 BT/BJ 0000 000 Installer maintenance 6 00 00 000 QA/QH 0000 000 Central station maintenance 6 00 00 000 QA/QH 0000 000 Standard time/Summer time changed 6 25 00 000 JD/UX 0000 000 Not Ready-to-arm partition 3 00 part. no. 000 NF/NF part. no. 000 Extended not Ready-to-Arm partition 3 00 part. no. 000 NF/NF part. no. 000 Partial arming partition 4 41 part. no. 16 NL/OP part. no. 000 Global arming partition 4 00 part. no. 16 CL/OP part. no. 000 Disarming partition 4 00 part. no. 16 OP/CL part. no. 000 Table 13 Structure of the main Reporting formats supported by the System 16The Digital Communicator will transmit the User Code ID Number less 1, of the User Code which generated the event (000 through 194), or the Digital Key/Card ID Number plus 199, of the Key/Card which generated the event (200 through 699). For example, if an event is generated by User Code no. 001, the Digital Communicator will transmit 000 (001 - 1); if an event is generated by Digital Key/Card no. 1, the Digital Communicator will transmit 200 (199 + 1). 16The Digital Communicator will transmit the User Code ID Number less 1, of the User Code which generated the event (000 through 194), or the Digital Key/Card ID Number plus 199, of the Key/Card which generated the event (200 through 699). For example, if an event is generated by User Code no. 001, the Digital Communicator will transmit 000 (001 - 1); if an event is generated by Digital Key/Card no. 1, the Digital Communicator will transmit 200 (199 + 1).

Stop Partition Alarms (with Key/Card)

87 This feature allows Keys/Cards to stop Partition Alarms. KYO 300-KYO100 APPENDIX 99 EVENT CONTACT ID SIA CL. CODE GROUP ZONE TYPE 1st 2nd Exit time on partition 6 00 part. no. 000 UX/UX part. no. 000 Entry time on partition 6 00 part. no. 000 UX/UX part. no. 000 Autoarming warning partition 6 00 part. no. 000 UX/UX part. no. 000 Memory alarm on partition 1 30 part. no. 000 BA/BR part. no. 000 Memory tamper on partition 1 37 part. no. 000 TA/TR part. no. 000 Valid key 4 22 00 key no. JP/UX 0000 key no. Key present on reader 4 22 00 reader no. JP/UX 0000 reader no. Valid key on partition 4 22 00 partition no. JP/UX 0000 partition no. Alarm stop on partition 6 00 part. no. 000 BC/UX part. no. 000 Alarm stop on panel 6 00 00 000 BC/UX 0000 000 Bypass zone 5 70 00 zone no. BB/BU 0000 zone no. Telephone line trouble 3 51 00 000 LT/LR 0000 000 Error printer 3 36 00 000 VT/VR 0000 000 Call queue full 6 24 00 000 JL/UX 0000 000 Timer 6 00 00 000 UX/UX 0000 000 Real time of zone 6 00 00 zone no. UA/UH 0000 zone no. Test 6 02 00 000 RP/UX 0000 000 Reset on partition 6 00 part. no. 000 BC/UX part. no. 000 Reset on panel 6 00 00 000 BC/UX 0000 000 Super key 6 00 00 000 UX/UX 0000 000 Key F on KeyFob 6 00 00 000 UX/UX 0000 000 Key A on KeyFob 6 00 00 000 UX/UX 0000 000 Key P on KeyFob 6 00 00 000 UX/UX 0000 000 Chime on partition 6 00 part. no. 000 UX/UX part. no. 000 Negligence on partition 4 04 part. no. 000 CD/UX part. no. 000 Delinquency on partition 6 00 part. no. 000 BT/BU part. no. 000 Block keypad 4 21 00 000 JA/UX 0000 000 Recognized user code 4 22 00 code no. JP/UX 0000 code no. Recognized user code on Keypad 4 22 00 keypadno. JP/UX 0000 keypadno. Recognized user code on Partition 4 22 00 partition no. JP/UX 0000 partition no. Invalid code 4 21 00 000 DD/DR 0000 000 Recognized installer code 6 27 00 000 LB/LX 0000 000 Second dialler on 3 50 00 000 UX/UX 0000 000 Kissoff recognized 3 50 00 000 UX/UX 0000 000 Start telephone call 3 50 00 000 UX/UX 0000 000 Teleservice requested 6 01 00 000 UX/UX 0000 000 Start Teleservice 6 01 00 000 RB/RS 0000 000 Dialler action OK 3 50 00 000 UX/UX 0000 000 Action on digital communicator OK 3 50 00 000 UX/UX 0000 000 Digital communicator action OK 3 50 00 000 UX/UX 0000 000 Teleservice action OK 3 50 00 000 UX/UX 0000 000 Dialler action failed 3 54 00 000 UX/UX 0000 000 Action on digital communicator failed 3 54 00 000 UX/UX 0000 000 Table 13 Structure of the main Reporting formats supported by the System