Key Pages of Document

To Bed - Sitting

(8 steps) 1 Adjust the Alenti lift to an appropriate height for the transfer. In some cases, it’s easier to transfer if the Alenti lift seat is a little bit higher than the bed. 2 Position the Alenti lift so that its front is facing the side of the bed. (See Fig. 13) 3 Active the brakes on the Alenti lift and make sure that they are locked. 4 Apply the wheel brakes on the bed. 5 Take of the safety belt and put the belt around the upper part of the hand rest-handle arm. 6 Fold back the hand rest-handle arm, away from the patient. 7 Let the patient move himself or herself t ...

Caregiver obligations shall be carried out by personnel with

sufficient Alenti lift knowledge following the instructions in this IFU. Every Day • Disinfect. The Alenti lift has to be disinfected immediately after every use. ArjoHuntleigh disinfectants should be used in recommended concentrations. See section Cleaning and Disinfection Instructions on page 34. Every Week • Check the mechanical attachments by placing a foot on the chassis and pull the seat upwards with both hands. (See Fig. 1) No gaps between the chassis and seat are allowed. • Visually check the sa ...

Design Policy and Copyright

® and ™ are trademarks belonging to the ArjoHuntleigh group of companies. © ArjoHuntleigh AB 2013. As our policy is one of continuous improvement, we reserve the right to modify designs without prior notice.The content of this publication may not be copied either whole or in part without the consent of ArjoHuntleigh AB. WARNING To avoid injury, always read this Instructions for Use and accompanied documents before using the product. Mandatory to read the Instructions for Use ...

The Alenti lift is subject to wear and tear, and the following actions must be performed when specified to make sure

that the product remains within its original manufacturing specification. PREVENTIVE MAINTENANCE SCHEDULE WARNING To avoid malfunction resulting in injury, make sure to conduct regular inspections and follow the recommended maintenance schedule. In some cases due to heavy use of the product and exposure to aggressive environment more frequent inspections should be carried out. Local regulations and standards may be more stringent than this recommended maintenance schedule. CA ...

Before the patient is transferred to the Alenti lift, make sure that:

• the backrest is attached to the correct side of the Alenti lift, • the safety belt is mounted on the Alenti lift, • the patient is undressed and covered. If using a robe, put it on front to back (opening towards patient’s back) and • the patient is in a correct sitting position. After each use, disinfect the Alenti lift to prevent cross- contamination. See section Cleaning and Disinfection Instructions on page 34. From a Standing Position (11 steps) 1 Activate the brakes on the Alenti lift and make sure that t ...

Hand rest - handle arm

5 Backrest - handle arm 6 Hand rest 7 Backrest 8 Transfer handles 9 Safety belt 10 Seat 11 Central Brakes 12 Scale (optional) 13 Control panel 14 Emergency High/Low 15 Battery release button (Emergency stop) 16 Battery 17 Bedpan (optional) 18 Bedpan holder handle (optional) 19 Bedpan holder (optional) 20 Leg support bar with straps (optional) Applied part: Type B. (seat including all attached parts to it) Protection against electric shock in accordance with IEC 60601-1. Part Designations ...

The scale is located on the Alenti lift pillar. (See Fig. 1)

To use the scale, if available, refer to the Scale IFU. Bedpan and Bedpan Holder (optional) (3 steps) 1 Fit the bedpan into the holder. (See Fig. 2) 2 The bedpan holder fits onto the back of the seat of the Alenti lift. (See Fig. 3) 3 Fold up the bedpan holder handle in to a locked position. (See Fig. 4) WARNING To avoid entrapment or pinching of genitals, make sure there is enough clearance during movement over the bathtub edge, toilet, bedpan or other furniture. Fig. 1 Fig. 2 Fig. 3 Fig. 4 Accessory Description ...

From a Standing and Raising Aid

(14 steps) ArjoHuntleigh has compatible standing and raising aids that can be used with the Alenti lift. They are Sara 3000 and Sara Plus. 1 Fold back the Alenti lift hand rest-handle arm. 2 Position the standing and raising aid with the patient in front of the Alenti lift seat. 3 Make sure the Alenti lift is as close as possible to the standing and raising aid, with the patient’s back towards the Alenti lift seat. (See Fig.3) 4 Activate the brakes on the Alenti lift and make sure that they are locked. 5 Lower the patient until he or she is sitting on the A ...

Arjohuntleigh Alenti user guide recommended for: Skin IQ 1000, Alpha Active 3, NIMBUS, maxi sky 440, Flowtron Excel.

⚠️ Download Safety

The Medical Equipment User manual manual (56 pages) is completely safe to download (last scan date: 18/02/2026).

Related PDF Instructions for Arjohuntleigh Alenti:

Medical Equipment Equipment: Frequently Requested

Have some Questions about Arjohuntleigh Alenti Device?

Get valuable and actionable advices from other Arjohuntleigh Alenti device users. Describe your problem or question, regarding the using of Alenti, in as much detail as possible, and other users will be able to answer you.