A&D EM Series Instruction Manual

Specifications

Brand: A&D
Category: Scales
Model: EM Series
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the A&D EM Series Instruction Manual online using the built-in PDF viewer.

Text of the manual

Step 1 Pass the cable B through the pole.

Step 2 While taking care not to pinch the cable, secure the pole to the weighing platform, using two screws. This manual describes how the EM Series Digital Platform Scales work. Step 3 Secure the bracket to the pole, using a nut and screw. Please read this manual completely before using the scale. Step 4 Connect cable A to cable B. Step 5 Bundle the excess cable and insert it into the pole. Step 6 Attach the display to the bracket. CAUTION  The scale is a precision instrument. When installing the scale, consider the following conditions to get the most out of your scale. Install the scale where it is not exposed to direct sunlight, where the temperature and relative humidity is stable and where there is no dust and draft. Install the scale on a solid and level surface which is free from vibration. The scale is not waterproof. Do not use it where it will get wet. Do not disassemble the scale. Do not open the case to repair or modify it. That may cause a fire or damage to the scale. Damage caused under such conditions will void the warranty. If the scale malfunctions, stop using it immediately. Contact the local A&D dealer. Three weight display resolutions are available, normal (1/3000), high (1/6000 or 1/7500), and higher (1/12000 or 1/15000). Two weighing platform sizes are available. The EM-KAM has a smaller pan and the EM-KAL has a larger pan. As a power source, either the AC adapter or internal rechargeable battery can be used. The counting function easily counts the number of objects of the same weight. The optional EM-03 serial interface can transmit the weight value to a personal computer or a printer. The following options are available for the EM series: EM-03 RS-232C serial interface EM-12 Adjustable bracket EM-13 Stabilizing foot ( for EM-30KAM , -60KAM ) EM-14 Desktop / Wall-mount stand When unpacking, check whether all of the following items are included. EM-15 Protective cover ●The EM series scale ●screws and nut ●AC adapter ●Instruction manual EM-16/17 Extension cable ( 3m/5m ) Note: Confirm the AC adapter type is correct for your local voltage Adjust the level of the scale, using the leveling feet. Confirm that the bubble of and receptacle type. the spirit level is in the center of the level. The best installation conditions are: stable temperature (-10℃ to 40℃) and relative humidity ( less than 85% ), solid and level surface, no drafts or vibration, no direct sunlight. Do not install the scale where there may be static electricity or sudden changes in temperature. EM series (Common for all models) Step 1 Press the 【ON/OFF】 key to turn the power ON. The display shows “ - - - - - ” if there is something placed on the weighing pan or the scale is unstable. Step 2 Press the 【UNITS/MODE】 key to select “kg” ( kg mode ). Step 3 When the display doesn't show zero, press the 【RE-ZERO】 key. Step 4 When a tare ( container ) is used, place the container on the weighing pan and press the 【RE-ZERO】 key to set the display to zero. Scale weighing range = weighing capacity - tare weight Step 5 Place the object to be weighed on the weighing pan or in the container. Wait for the STABLE indicator to turn on and read the value. Step 6 Remove the objects from the weighing pan. Step 7 Press the 【ON/OFF】 key to turn the power OFF. When the auto power-off function is enabled, the scale turns off automatically after 5 minutes of stable condition and Error displayed. Display and symbols Step 1 Press the 【UNITS/MODE】 key to select “pcs”. Step 2 Press and hold the 【UNITS/MODE】 key to enter the sample unit weight storing mode. ( The figure on the left is the number of samples. ) Step 3 To change the number of samples, press the 【ON/OFF】 key. It may be set to 5, 10, 20, 50 or 100. Step 4 If necessary, place a container on the weighing pan and press the 【RE-ZERO】 key. Confirm that the right side of the number of samples shows zero. Step 5 Place the correct number of samples on the weighing pan or in the container. In this example, place 20 pieces of samples. Step 6 Confirm that the STABLE indicator is turned on. Press the 【UNITS/MODE】 key to calculate and store the unit weight. The scale is set to count object with this unit weight. The unit weight is stored in memory, even if the power is turned off. Note The total weight of samples should be more than shown below, regardless of the number of samples. Weighing capacity of 30 kg :100g, capacity of 60 kg :200g, capacity of 150 kg:500g If not, the display shows “ lo ut ” and returns to the display of step 5. Increase the number of samples (step 3) and try again. Turns on when the weight value is stable. Turns on when the scale shows zero. STABLE ZERO NET Turns on when the NET weight is displayed. ( The tare operation is in progress. ) HOLD Turns on when the scale hold the weight. Battery indicator Changes as the battery capacity decreases as shown to the left. Weighing units “kg”:Basic weighing mode in kg. “pcs” (pieces):Counting mode which determines a unit weight (the weight of one piece) from the known pieces of samples and calculates how many pieces are on the weighing pan using the unit weight. / 1WMPD4002222C 1.1. Precautions 1.2. Features 1.3. Unpacking 1. INTRODUCTION EM SERIES Digital Platform Scale 3. INSTALLATION 3.1. Setting up the Scale Screw Step 2 Cable A Bracket Cable B Step 4 Step 1 Step 5 Step 3 Step 6 Display Nut Pole Leveling foot 3.2. Installing the Scale 2.  DESCRIPTION OF EACH PART Display Leveling foot Weighing pan Spirit level Pole AC adapter jack Calibration switch Battery indicator STABLE indicator NET indicator ZERO indicator ON/OFF key RE-ZERO key Weighing units UNITS / MODE key → → 4. BASIC WEIGHING OPERATION 5. COUNTING MODE 0 pcs 5 0 pcs Number of samples 20 0 pcs Confirm zero 20 - pcs 20 pcs Container Weighing pan Spirit level Screws HOLD indicator EM-03 option RS232C (D-sub 9 pin)

This function adjusts the scale for accurate weighing. Calibrate the scale when it is

Step 1 Follow the function setting procedure to display “ init”. first used, when it has been moved, when the ambient environment has changed or Step 2 Press the 【RE-ZERO】 key. The STABLE indicator for regular calibration. turns on. Note: Step 3 Press the 【UNITS/MODE】 key. The scale displays Before calibration using a weight, set the gravity acceleration value. “end”. The function settings have restored to the factory setting values. Step 1 Press the 【ON/OFF】 key to turn the power on. Step 2 Press the Calibration switch to display “Cal”. Step 3 To perform a calibration using a weight, press the 【RE-ZERO】 key to display “Cal 0”. Go to step 4. To compensate the gravity acceleration value, press the 【UNITS/MODE】 key to display the gravity acceleration value (example “9.7885”). Go to step 7. Do not disassemble the scale. Contact your local A&D dealer if the scale needs service or repair. Calibration using a weight (from step 3) Use the original packaging for transportation. Step 4 Confirm that nothing is placed on the weighing pan The scale is not waterproof. Ensure no water is allowed inside the scale. and the STABLE indicator is turned on. Use the scale under the specified operation conditions: Temperature of -10 ℃ Press the 【RE-ZERO】 key. The scale calibrates to 40℃, relative humidity of less than 85% without condensation. the zero point and displays “Cal 20”. If you do not The rechargeable battery naturally self-discharges without usage. Do not leave need SPAN calibration, turn the power off. 【CAL】 the battery for more than 30 days in storage and charge the battery periodically. Step 5 Place a calibration weight on the pan with the same value (kg) as displayed on the weighing pan. 【CAL】 Indicates that an object beyond the weighing capacity has To change the displayed value. been placed on the weighing pan. 【UNITS/MODE】 Remove the object. To calibrate with the weighing capacity. (“Cal f”) Indicates that the weight sensor received strong force Step 6 Wait for the STABLE indicator to turn on. Press the upward. There is a possibility that the weight sensor or 【RE-ZERO】 key. The scale calibrates SPAN, displays internal circuit have a failure. “end” and returns to the weighing mode. Remove the weight. The display shows zero automatically. Indicates that the sample weight is too light to set the unit. Increase the number of samples. Gravity acceleration correction (form step 3) Step 7 Change the gravity acceleration value using the following keys. Indicates that the battery is depleted. Charge the battery. It takes approximately 8 hours to charge in full. 【UNITS/MODE】 To shift the blinking digit. Indicates that the voltage of the AC adapter is too high. 【RE-ZERO】 Use the specified AC adapter. To increase the value of the blinking digit by one. Check the Load Cell cable connection. ( See 3.1. Setting up the Scale) Step 8 Press and hold the 【UNITS/MODE】 key and press the The internal circuit may have a failure. (“*”indicates the 【RE-ZERO】 key. Then, release the 【UNITS/MODE】 error number.) Contact the local A&D dealer. key. “end” is displayed and the new value is stored. If the errors described above can not be released or other errors are displayed, For further information on calibration, contact the local A&D dealer. contact the local A&D dealer. Step 1 Press the 【ON/OFF】 key to turn the power off. Step 2 Press and hold the 【RE-ZERO】 key and press the 【ON/OFF】 key. The software version is displayed. “**” indicates the software version number. Step 3 Press the 【UNITS/MODE】 key to display the first item. “ ” indicates the current setting. Step 4 Change the item or parameter using the following keys. 【UNITS/MODE】 ⇒ To display the next item. 【RE-ZERO】 ⇒ To increase the parameter value by one. Step 5 When the parameter is changed (the STABLE indicator is turned off) press the 【UNITS/MODE】 key to store the change. After “end”, the next item is displayed. This interface allows the scale to be connected to a printer or a personal computer. Use a D-sub 9 pin cable (straight type) . (Ex.) 8 bits / Non parity Baud rate: 2400 , 4800 , 9600 bps Start bit: 1 bit Stop bit: 1bit Data bits: set “ btpr ” Terminator: CRLF (CR: 0Dh, LF: 0Ah ) Start bit Data bits Stop bit Example of output data: Weight data “kg” Unstable weight data “kg” Counting data “pcs” Out of weighing range “kg” Header Unit Command list “Q” command : Command to request the current weight value. “Z” command : Same operation as the RE-ZERO switch. Reply to the command   Factory setting If the received command is not for the EM series scale. 【RE-ZERO】 【UNITS】 Selects a decimal point type ※Depending on your location Selecting Units “Unit” High(1/6000 or 1/7500) Higher(1/12000or1/15000) Zero tracking disabled Zero tracking enabled 0 The STABLE indicator indicates that the unit is selected and can be used for weighing. Terminator 9600 bps Stream mode Command mode Not used 8 bits / Non parity 7 bits / EVEN 7 bits / ODD Always on Auto Auto power-off enabled Normal(1/3000) Hold enabled Separator DATA Units are displayed in turn, as shown below: g → kg → lb → oz → lb oz → pcs Hold the averaged weight. The display will not show Stable indicator. Dot ( .) Comma( ,) 2400 bps 4800 bps Item Parameter Auto power-off function “poff” 0 1 Always off Auto-print ± data mode Auto-print + data mode Hold disabled “Auto”:The backlight turns off automatically after 3 seconds of stable condition Tracks the zero drift Backlight “lit” Display resolution “re5o” Zero tracking function “trc” Decimal point “pnt” Serial interface Baud rate “bp5” Serial interface Data bits / parity “btpr” 2 When the optional EM-03 serial interface is used. Set the parameters of the data format ( “bp5” and “btpr” )and data output mode. 2 Hold function “Hold” 1 2 0 1 2 Serial interface Data output mode “prt” 3 4 0 0 1 1 0 1 0 0 1 2 1 Weighing capacity Model 0 1 Linearity Sensitivity drift Turns the power off automatically after 5minutes of stable condition. Changes ”d”, minimum display Description Auto power-off disabled 30 kg 60 kg 150 kg 10 g 20 g EM-30KAM EM-60KAM / EM-60KAL EM-150KAL 2 g 5 g 10 g 10 g 20 g 50 g 5 g 150 kg 5 g 10 g 20 g Approximately 200 hours at 25℃ (Backlihgt off) Approximately 70 hours at 25℃ (Backlihgt on) ±0.01% / ℃ (5℃ to 35℃) 7-segment LCD with backlight, Character height of 26 mm. Approximately 10 times per second ( Without EM-03 ) EM-KAM:300x560x450mm / EM-KAL: 400x710x750mm EM-KAM: 4 kg / EM-60KAL: 7kg / EM-150KAL: 9.5kg ±10 g ±20 g ±50 g EM-KAM:300x350mm / EM-KAL: 400x500mm Confirm the AC adapter type is correct for your local voltage and receptacle type. AC adapter or rechargeable battery -10℃ to 40℃, 85%RH or less, No condensation 30 kg 60 kg Weighing pan size Display Display update rate Operation conditions Restores the setting to the factory setting values. Read “7.1. Initialization” Initialization “init” Minimum display “d” With high resolution With higher resolution Repeatability (Standard deviation) Power supply Battery life Dimensions Mass (approximately) Calibration weight 97885 6. CALIBRATION 97885 97885 7.  FUNCTION SETTING Cal Cal 0 end Cal 0 97885 97895 end p-1.** poff 1 poff 0 re5o 0 end Weighing pan Weight 7.1. Initialization init init end 8. MAINTENANCE 8.1. Notes on Maintenance 8.2. Error Display Oe -e lo ut Olb OHb error* 9. SPECIFICATIONS 9.1. Specifications 9.2. Serial Interface LSB 0 1 2 3 4 5 6 MSB 7 Q CR LF Z CR LF ? CR LF S T , 0 0 1 2 3 . 4 5 k g CR LF + Q T , 0 0 0 1 0 0 0 0 P C CR LF + O L , 9 9 9 9 9 . 9 9 k g CR LF + U S , 0 0 1 2 3 . 4 5 k g CR LF + Cal 20 Cal 30 ------

Other Scales Manuals