Comelit VIP System Installer Manual

Specifications

Brand: Comelit
Category: Intercom System
Model: VIP System (Installer Manual)
File Type: PDF
File Size: —
Pages: 88

Read Online

Read the Comelit VIP System Installer Manual online using the built-in PDF viewer.

Text of the manual

Fonts are (c) Bitstream (see below). DejaVu changes are in public domain.

Glyphs imported from Arev fonts are (c) Tavmjong Bah (see below) Bitstream Vera Fonts Copyright ------------------------------ Copyright (c) 2003 by Bitstream, Inc. All Rights Reserved. Bitstream Vera is a trademark of Bitstream, Inc. Permission is hereby granted, free of charge, to any person obtaining a copy of the fonts accompanying this license ("Fonts") and associated documentation files ("Font Software"), to reproduce and distribute the Font Software, including without limitation the rights to use, copy, merge, publish, distribute, and/or sell copies of the Font Software, and to permit persons to whom the Font Software is furnished to do so, subject to the following conditions: The above copyright and trademark notices and this permission notice shall be included in all copies of one or more of the Font Software typefaces. The Font Software may be modified, altered, or added to, and in particular the designs of glyphs or characters in the Fonts may be modified and additional glyphs or characters may be added to the Fonts, only if the fonts are renamed to names not containing either the words “Bitstream” or the word “Vera”. This License becomes null and void to the extent applicable to Fonts or Font Software that has been modified and is distributed under the "Bitstream Vera" names. The Font Software may be sold as part of a larger software package but no copy of one or more of the Font Software typefaces may be sold by itself. THE FONT SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF COPYRIGHT, PATENT, TRADEMARK, OR OTHER RIGHT. IN NO EVENT SHALL BITSTREAM OR THE GNOME FOUNDATION BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, INCLUDING ANY GENERAL, SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF THE USE OR INABILITY TO USE THE FONT SOFTWARE OR FROM OTHER DEALINGS IN THE FONT SOFTWARE. Except as contained in this notice, the names of Gnome, the Gnome Foundation, and Bitstream Inc., shall not be used in advertising or otherwise to promote the sale, use or other dealings in this Font Software without prior written authorization from the Gnome Foundation or Bitstream Inc., respectively. For further information, contact: fonts at gnome dot org. Arev Fonts Copyright ------------------------------ Copyright (c) 2006 by Tavmjong Bah. All Rights Reserved. Permission is hereby granted, free of charge, to any person obtaining a copy of the fonts accompanying this license ("Fonts") and associated documentation files (the "Font Software"), to reproduce and distribute the modifications to the Bitstream Vera Font Software, including without limitation the rights to use, copy, merge, publish, distribute, and/or sell copies of the Font Software, and to permit persons to whom the Font Software is furnished to do so, subject to the following conditions: is furnished to do so, subject to the following conditions: The above copyright and trademark notices and this permission notice shall be included in all copies of one or more of the Font Software typefaces. The Font Software may be modified, altered, or added to, and in particular the designs of glyphs or characters in the Fonts may be modified and additional glyphs or characters may be added to the Fonts, only if the fonts are renamed to names not containing either the words "Tavmjong Bah" or the word "Arev". This License becomes null and void to the extent applicable to Fonts or Font Software that has been modified and is distributed under the "Tavmjong Bah Arev" names. The Font Software may be sold as part of a larger software package but no copy of one or more of the Font Software typefaces may be sold by itself. THE FONT SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF COPYRIGHT, PATENT, TRADEMARK, OR OTHER RIGHT. IN NO EVENT SHALL TAVMJONG BAH BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, INCLUDING ANY GENERAL, SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF THE USE OR INABILITY TO USE THE FONT SOFTWARE OR FROM OTHER DEALINGS IN THE FONT SOFTWARE. Except as contained in this notice, the name of Tavmjong Bah shall not be used in advertising or otherwise to promote the sale, use or other dealings in this Font Software without prior written authorization from Tavmjong Bah. For further information, contact: tavmjong @ free. fr. Chapter 1: Introduction to the VIP system ..............................................................................................................................5 What is the VIP system? ...............................................................................................................................................................................5 Main features .................................................................................................................................................................................................5 General structure of a VIP system ...............................................................................................................................................................5 Chapter 2: Description of products and accessories ............................................................................................................6 Software .........................................................................................................................................................................................................6 VIP Manager Art. 1449 VIP system configuration software ......................................................................................................................6 Power supply units and system connection accessories .........................................................................................................................6 VIP system riser power supply unit 120 W Art. 1441A ..............................................................................................................................6 VIP system riser power supply unit 100 W Art. 1441 ................................................................................................................................6 Power supply unit Art. 1395 / Art. 1595 for external units .........................................................................................................................7 VIP system POE power supply unit for monitor Art. 1451 ........................................................................................................................7 Switch Art. 1440 ........................................................................................................................................................................................7 VIP system riser signal repeater module Art. 1447 ...................................................................................................................................8 VIP system device barcode reader Art. 1450 ...........................................................................................................................................8 Internal units ..................................................................................................................................................................................................9 Planux backplate Art. 6231 and Planux monitor Art. 6202 ........................................................................................................................9 7Stelle monitor Art. 6501 ..........................................................................................................................................................................10 Smart monitor Art. 6304 ............................................................................................................................................................................10 Easycom door-entry phone Art. 6203 .......................................................................................................................................................11 VIP switchboard Art. 1952 ........................................................................................................................................................................11 Powercom series external units ..................................................................................................................................................................12 Powercom module Art. 3331/0 - 1 - 2 for audio/video units ......................................................................................................................12 Powercom series colour audio/video unit for VIP system Art. 4662C .......................................................................................................12 Powercom call button module Art. 3337/3 - 4 - 6 ......................................................................................................................................12 Powercom series backlit indication module Art. 3327 ...............................................................................................................................13 Powercom series digital call module for VIP system Art. 3370 .................................................................................................................13 IKall series external units .............................................................................................................................................................................14 IKall module Art. 33400 - 33401 - 33402 for audio units ...........................................................................................................................14 Warning • Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force. In mains-powered devices, do not tamper with the internal elements offering protection against short circuits and overcurrents. • All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper use of the apparatus, for any alterations made by others for any reason or for the use of non-original accessories or materials. • All the products comply with the requirements of the 2014/30/UE, 2014/35/UE directives, as certified by the CE mark they carry. • Do not route the riser wires in proximity to power supply cables (230/400V). • Installation, mounting and assistance procedures for electrical devices must only be performed by specialised electricians. • The electrical system of the building must be fitted with an (easily accessible) omnipolar mains switch with a contact opening of at least 3 mm, which is capable of cutting off the power supply for mains-powered devices. • Cut off the power supply before carrying out any maintenance work. • Place the protection back over the terminals and close the inspection door after every procedure. • The device conforms to standard EN60950-1 relating to the safety of information technology equipment. • Do not press and hold the audio hook while the handset is lifted. TABLE OF CONTENTS

IKall module Art. 33410 - 33411 - 33412 for audio/video units .................................................................................................................14

IKall series audio unit for VIP system Art. 1682 ........................................................................................................................................14 IKall series colour audio/video unit for VIP system Art. 4682C .................................................................................................................15 IKall call button module Art. 33433 - 33434 - 33436 .................................................................................................................................15 IKall series digital call module for VIP system Art. 3360A .........................................................................................................................15 Vandalcom series external units .................................................................................................................................................................16 Vandalcom series digital call module for VIP system Art. 3270, for Powercom external unit Art. 4662C .................................................16 Vandalcom series digital call module for VIP system Art. 3070B, for Powercom external units Art. 4662C and IKall external units Art. 4682C .....16 Vandalcom series digital call module for VIP system Art. 3272, for Powercom external unit Art. 4662C .................................................17 Vandalcom series digital call module for VIP system Art. 3072B, for Powercom external units Art. 4662C and IKall external units Art. 4682C .....17 Module Art. 3268I/0 -1 - 2 designed for a/v units, iKall series ...................................................................................................................18 Module Art. 3269/0 - 1 - 2 designed for a/v units, Powercom series ........................................................................................................18 Module Art. 3262I/0 -1 - 2 designed for audio units, IKall series ..............................................................................................................18 Vandalcom series 4-button module Art. 3064/C for VIP system ...............................................................................................................18 VIP system accessories ...............................................................................................................................................................................19 Remote camera module Art. 1445 ............................................................................................................................................................19 VIP system actuator relay module Art. 1443 .............................................................................................................................................20 PAL / NTSC video output module Art. 1446 ..............................................................................................................................................21 Expansion module Art. SK9071 ................................................................................................................................................................21 Chapter 3: System preparation and specifications ................................................................................................................22 Connection distances ...................................................................................................................................................................................22 Connection distances from power supply unit Art. 1395 / Art. 1595 to external unit .................................................................................22 Connection distances between external unit and Switch Art. 1440 ..........................................................................................................22 Connection distances between 2 Switches Art. 1440 ...............................................................................................................................22 Connection distances from Switch Art. 1440 / Repeater Art. 1447 to door-entry phones / door entry monitors .......................................23 Connection distances from Switch Art. 1440 / Repeater Art. 1447 to switchboard Art. 1952 ...................................................................23 Expanding a system using repeater Art. 1447 ..........................................................................................................................................23 Guide to fitting a UTP / STP RJ45 Direct network cable ............................................................................................................................24 Chapter 4: Mounting external units and internal units ..........................................................................................................27 Mounting Powercom series external units .................................................................................................................................................28 Mounting external unit Art. 4662C and additional buttons Art. 3337/3 - 4 - 6 ...........................................................................................28 Mounting actuator module Art. 3327 .........................................................................................................................................................29 Mounting digital directory Art. 3370 ..........................................................................................................................................................29 Mounting IKall series external units ............................................................................................................................................................30 Mounting external unit Art. 4682C and additional buttons Art. 33433 - 33434 - 33436 ............................................................................30 Mounting digital directory Art. 3360A ........................................................................................................................................................31 Mounting Vandalcom series external units ................................................................................................................................................32 Connecting audio-video unit Art. 4662C for use with buttons on Vandalcom external unit Art. 3269/1 - 2 ...............................................32 Connecting audio unit 1682 or audio-video unit Art. 4682C for use with buttons on Vandalcom external unit Art. 3262I/1 - 2 and Art. 3268I/1 - 2 ....33 Mounting audio-video unit Art. 4662C or 4682C for use with additional buttons Art. 3064/C ...................................................................34 Mounting digital directories Art. 3270 - 3272 with Powercom external unit Art. 4662C ............................................................................35 Mounting digital directories Art. 3070B - 3072B with IKall external unit Art. 4682C..................................................................................36 Mounting internal units ................................................................................................................................................................................37 Mounting Planux monitor Art. 6202 with flush-mounted box Art. 6117 .....................................................................................................37 Mounting Planux monitor Art. 6202 with wall bracket Art. 6120 ................................................................................................................38 Mounting Sette Stelle monitor Art. 6501 ...................................................................................................................................................39 Mounting 7Stelle monitor Art. 6501 with flush-mounted box Art. 6517 .....................................................................................................40 Mounting Easycom monitor Art. 6203 .......................................................................................................................................................41 Mounting Smart monitor Art. 6304 with wall bracket Art. 6320 .................................................................................................................42 Mounting Smart monitor Art. 6304 with flush-mounted box Art. 6117 .......................................................................................................43 Chapter 5: Installation programming ......................................................................................................................................44 Mac Address ..................................................................................................................................................................................................44 VIP code .........................................................................................................................................................................................................44 Reset procedure for external unit Art. 4662C and 4682C ..........................................................................................................................44 Manually programming buttons on external unit Art. 4662C ....................................................................................................................46 Manually programming buttons on external unit Art. 4682C ....................................................................................................................47 Assigning module index to additional button products Art. 3337/3 - 4 - 6 .............................................................................................48 Assigning module index to additional button products Art. 33433 - 33434 - 33436 ...............................................................................49 Programming internal units .........................................................................................................................................................................50 Planux monitor Art. 6202 and Smart monitor Art. 6304 (only with optional buttons Art. 6332) .................................................................50 Accessing the installer menu ..............................................................................................................................................................50 Setting the menu language ................................................................................................................................................................50 Programming the VIP code for main Planux monitors .......................................................................................................................51 Programming the VIP code for secondary Planux monitors ...............................................................................................................51 Configuring 1 - 2 or Self-ignition buttons ............................................................................................................................................52 Configuring the key button .................................................................................................................................................................53 Configuring the Privacy / Doctor button ..............................................................................................................................................54 Configuring the intercom directory .....................................................................................................................................................54 Configuring the self-ignition directory .................................................................................................................................................55 Configuring the Actuator Directory .....................................................................................................................................................56 Setting the Door Open function ..........................................................................................................................................................57 Setting the Alarm function ..................................................................................................................................................................58 Setting the ringtone repetition ............................................................................................................................................................58 Setting call times ................................................................................................................................................................................59 Setting automatic answer ...................................................................................................................................................................59 Video memory records always ...........................................................................................................................................................60 Activate output ....................................................................................................................................................................................60 Call divert ...........................................................................................................................................................................................61 Reset configuration ............................................................................................................................................................................61

7Stelle monitor Art. 6501 ..........................................................................................................................................................................62

Accessing the installer menu ..............................................................................................................................................................62 Configuring buttons ............................................................................................................................................................................62 Configuring functions ..........................................................................................................................................................................62 Intercom function .........................................................................................................................................................................62 Self-ignition function .....................................................................................................................................................................62 Alarm function ..............................................................................................................................................................................63 Lock-release function ...................................................................................................................................................................63 Actuator function ..........................................................................................................................................................................63 Activate output function ................................................................................................................................................................63 Configuring the monitor ......................................................................................................................................................................64 VIP address .................................................................................................................................................................................64 About ............................................................................................................................................................................................64 Reset configuration ......................................................................................................................................................................64 Special Settings ..................................................................................................................................................................................64 Actuator Directory ........................................................................................................................................................................64 Camera Directory .........................................................................................................................................................................65 Intercom Directory ........................................................................................................................................................................65 Set ringtone repetition ..................................................................................................................................................................65 Set call times ................................................................................................................................................................................65 Call divert .....................................................................................................................................................................................66 Alarms ..........................................................................................................................................................................................66 Door open ....................................................................................................................................................................................66 Activate output .............................................................................................................................................................................66 Automatic answer ........................................................................................................................................................................66 Video memory records always .....................................................................................................................................................66 Porter switchboard Art. 1952 ....................................................................................................................................................................67 Accessing the installer menu ..............................................................................................................................................................67 Setting the VIP Address .....................................................................................................................................................................67 Setting the associated camera ...........................................................................................................................................................67 Setting the associated video output ...................................................................................................................................................67 Programming the self-ignition key ......................................................................................................................................................68 Programming the lock-release key .....................................................................................................................................................68 Activating / deactivating the OFF key .......................................................................................................................................................68 Setting the call times .................................................................................................................................................................................69 Setting call divert ......................................................................................................................................................................................69 Setting activations on call .........................................................................................................................................................................69 Chapter 6: Wiring diagrams .....................................................................................................................................................70 Connecting Powercom call button module Art. 3337/3-4-6 .......................................................................................................................70 Connecting Powercom series digital call module Art. 3370 .....................................................................................................................71 Connecting backlit module with actuator relay Art. 3327 .........................................................................................................................72 Connecting IKall call button module Art. 3343/3-4-6 .................................................................................................................................73 Connecting IKall series audio unit for VIP system Art. 1682 ....................................................................................................................74 Connecting IKall series digital call module Art. 3360A .............................................................................................................................75 Connecting Vandalcom series digital call modules Art. 3070B and Art. 3072B with IKall series external units Art. 4682C or 1682 .76 Connecting Vandalcom series digital call modules Art. 3270 and Art. 3272 with Powercom series external unit Art. 4662C ...........77 Connecting Art. 3064/C with audio-video unit 4682C or audio unit Art. 1682 ........................................................................................78 Connecting remote camera module Art. 1445 ............................................................................................................................................79 Connecting PAL / NTSC module Art. 1446 ..................................................................................................................................................80 Connecting repeater module Art. 1447 .......................................................................................................................................................81 Connecting IO module Art. 1443 and expansion device Art. SK9071 ......................................................................................................82 Request to exit (RTE) button input variant .................................................................................................................................................83 Planux VIP output and input variant ...........................................................................................................................................................83 7Stelle output and input variant ..................................................................................................................................................................84 Smart output and input variant ....................................................................................................................................................................84 Easycom output and input variant ..............................................................................................................................................................85 Connection of Vandalcom nameplate lighting lamp with audio unit Art. 1682 or audio-video unit Art. 4682C (Ikall) .........................85 Connecting Planux VIP additional ringtone variant ...................................................................................................................................86 Connecting 7Stelle additional ringtone variant ..........................................................................................................................................86 Connecting Smart additional ringtone variant ...........................................................................................................................................86 Connecting Easycom additional ringtone variant .....................................................................................................................................86

Chapter 1: Introduction to the VIP system

What is the VIP system? The VIP system is the new IP video entry phone system combining powerful performance with ease of installation. The VIP network, based on a connection via Ethernet cable, connects an infinite number of users in simultaneous conversations and with no distance restrictions. It integrates a video entry phone system, burglar alarm, video surveillance, home automation and access control functions into a single system. The VIP System can be used to create either a dedicated, proprietary network or integrated into an existing LAN, creating a video entry phone system that runs in parallel with other existing systems. General structure of a VIP system Below is a synoptic diagram providing a general illustration as to how a VIP system can be laid out. The optimal freedom offered by the VIP system means that networks can be created using cascade or branch connections, with no restrictions. Main features The VIP System delivers optimal performance across an intelligible infrastructure, untangling the communication, control, security, automation and monitoring apparatus needed for access and building control. • Multiple simultaneous audio-video conversations • An unlimited number of users and devices can be plugged into the network • No limits on the number of connected entrance panels, internal units, switchboards and cameras • All network devices are connected to the network via RJ45 plug • Simultaneous communication capabilities between all network users • Memovideo function installed as standard on all monitors • Interface management for lifts and additional floors • Integrated access control and video surveillance options • Alarms or panic messages can be sent to porter switchboards • Audio and text messages between users and switchboards • "Follow me" and data transfer to external applications (PC or telephone) • Remote home automation management

Chapter 2: Description of products and accessories

Power supply units and system connection accessories +V+V -V -V N L Power supply unit Art. 1441A, to power all accessories connected to the riser (not including external units). Technical characteristics Input voltage 100 - 240 V~ (3 A) Output voltage 48 V DC (2.5 A) Power 120 W Frequency 50/60 Hz Temperature thresholds -30°C / +55°C Dimensions 4 DIN modules / H: 12.5 cm W: 6.5 cm D: 10.7 cm VIP system riser power supply unit 120 W Art. 1441A Terminal blocks for connection +V +V -V -V: Riser power supply terminals. L N: Alternating 230 V~ network terminals. : Earth. connection terminal. Terminal blocks for connection +V -V: Riser power supply terminals. L N: Alternating 230 V~ network terminals. Power supply unit Art. 1441, to power all accessories connected to the riser (not including external units). Technical characteristics Input voltage 100 - 240 V~ (3 A) Output voltage 56 V DC (1.8 A) Power 100 W Frequency 50/60 Hz Temperature thresholds -30 +55 Dimensions 6 DIN modules / H: 9.3 cm W: 9.9 cm D: 5.3 cm VIP system riser power supply unit 100 W Art. 1441 Software CD-ROM software for PC installation, for the programming and configuration of all wired devices in the system. Also allows button programming and management of names in external unit directories. Includes a special cable for connection between switch 1440 and PC. When connecting a PC to a VIP system, the special cable supplied with software Art. 1449 must be used VIP Manager Art. 1449 VIP system configuration software • Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force. Do not tamper with the internal elements offering protection against short circuits and overcurrents. • The electrical system of the building must be fitted with an (easily accessible) omnipolar mains switch with a contact opening of at least 3 mm, which is capable of cutting off the power supply of the device. • Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force. Do not tamper with the internal elements offering protection against short circuits and overcurrents. • The electrical system of the building must be fitted with an (easily accessible) omnipolar mains switch with a contact opening of at least 3 mm, which is capable of cutting off the power supply of the device.

Power supply unit Art. 1395 / Art. 1595 for external units

VIP system POE power supply unit for monitor Art. 1451 The power supply unit converts an Ethernet connection into a POE-type connection supplying an internal unit. The power supply unit is necessary if VIP devices (door entry monitors / door-entry phones) are installed on existing Ethernet networks with non-POE (Power Over Ethernet) connections. Indicator LED ON: Power supply enabled indication FAULT: Error indication CONNECT: Ethernet cable connected to OUT port indication Technical characteristics Input voltage 100 - 240 V~ (0.95 A) Output voltage 56 V (0.35 A) Power 33.6 W Frequency 50 - 60 Hz Temperature thresholds -20 / +50°C Dimensions H: 3.7 cm W: 6.5 cm D: 16.4 cm Ethernet ports OUT: for the connection of internal units IN: for the connection of a non-POE Ethernet network Switch Art. 1440 The Ethernet Switch module Art. 1440 performs two main functions: • Directing data VIP system data packages. • Provide a power supply for the extensions connected to it and to any switch/repeaters connected in cascade. Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 36/57 V 3A Max. Temperature thresholds -30 / +55°C Dimensions 4 DIN modules / H: 6.2 cm W: 7.2 cm D: 9 cm Ethernet port status indicator LED Lit steadily: port in standby Flashing: data passing through the port Off: port not connected IN1 IN2 100 Mb riser Ethernet ports. Used for the connection of distributors, such as repeaters, switches, internal units etc. OUT1 OUT2 OUT3 OUT4: 10 Mb extension Ethernet port. Used for the connection of distributors, such as repeaters, switches, internal units etc. + -: External power supply terminals. Connection of power supply unit Art. 1441 or Art. 1441A For correct operation of the system protecting Art. 1440, the riser must be connected with input on port IN1 and output on port IN2 Technical characteristics Art. 1395 Art. 1595 Input voltage 207 - 257 V~ (3 A) 120-230 V~ (0,8 A) Output voltage 12 V~ (1,8 A) 33 V ± 3% (0,5 A) Power 60 W Frequency 50/60 Hz Temperature thresholds -20 / +40°C Dimensions 4 DIN modules / H: 9 cm W: 7.15 cm D: 6.2 cm Terminal blocks for connection Art. 1395 230V ~: Alternating 230 Vac network terminals. 0 12~: Power supply output terminals. Terminal blocks for connection Art. 1595 120-230 V ~: Power supply terminals. + -: Power supply output terminals. • Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force. Do not tamper with the internal elements offering protection against short circuits and overcurrents. • The electrical system of the building must be fitted with an (easily accessible) omnipolar mains switch with a contact opening of at least 3 mm, which is capable of cutting off the power supply of the device.

The repeater module Art. 1447 is used to extend networks, making it possible to connect a VIP device at a greater distance than would be possible

using a single section of point-to-point Ethernet and, if necessary, to connect two risers to each other. 1. Ethernet In port 2. Ethernet Out port 3. JP2 Jumper: negative pole separation (GND) 4. JP1 Jumper: positive pole separation (+) Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 36/57 Vdc 3A Max. Temperature thresholds -30 / +55°C Dimensions 4 DIN modules / H: 3.6 cm W: 6.5 cm D: 8.3 cm The two Ethernet ports are polarised as an IN input port and an OUT output port. In general, the repeater will receive power from the input port and supply power to the remote device (door-entry phone, switch, repeater) via the output port. This distinction was made to interrupt power supply propagation between the In port and the Out port by removing Jumpers JP1 and JP2, in order to separate - for example - the power supplies to two risers. The device even operates correctly if the output port is switched with the input port. In this case, however, it will no longer be possible to interrupt power supply propagation. VIP system riser signal repeater module Art. 1447 Barcode reader for identifying the unique code of the devices making up the VIP system, for example: door-entry phones, door entry monitors, external units, actuators, etc... Technical characteristics Power supply USB VIP system device barcode reader Art. 1450

Planux backplate Art. 6231 and Planux monitor Art. 6202

1 2 3 4 0V PAN CFP S+ 0V OP- OP+ 0V AL OUT 1 Reference for CFP and PAN terminals Panic contact terminal Floor door call contact terminal Additional ringtone terminals Optically coupled input terminals Reference for OUT1 and AL terminals Output terminal 12 V MAX 100 mA Alarm contact terminal 0V PAN CFP S+ 0V OP- OP+ 0V AL OUT 1 Technical characteristics Absorption Min. 0.7 W Max. 2.6 W (value for complete backplate + monitor product) Power supply 36/57 Vdc 3A Max. Dimensions H: 6.2 cm W: 7.2 cm D: 9 cm 1. Connection terminals 2. VIP - POE selector for fitting to the latter if the internal unit is used on a standard - not VIP - PoE network 3. RJ45 Ethernet connector for connecting the internal unit to the VIP network 4. SD Card slot For wiring details, refer to the diagrams section at the end of this manual. We recommend using VIP Manager software Art. 1449 to configure the internal unit (see specific manual). However, the main parameters can also be configured directly, on the device itself (see page 50).

Min. 0.7 W Max. 2.6 W

Power supply 36/57 Vdc 3A Max. 3 1 2 4 7Stelle monitor Art. 6501 Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 36/57 Vdc 3A Max. 0V OUT1 AL 0V PAN CFP S+ OP- OP+ Reference for CFP, PAN and S+ terminals Panic contact terminal Floor door call contact terminal Additional ringtone terminals Optically coupled input terminals Reference for OUT1 and AL terminals Output terminal 12 V MAX 100 mA Alarm contact terminal Smart monitor Art. 6304 0V OUT1 AL 0V PAN CFP S+ IN1 Reference for CFP, PAN and S+ terminals Panic contact terminal Floor door call contact terminal Additional ringtone terminals Reference for OUT1 and AL terminals Output terminal 12 V MAX 100 mA Alarm contact terminal Input terminal 1 0V OUT1 AL 0V PAN CFP S+ IN1 1 2 3 4 1. Connection terminals 2. VIP - POE selector for fitting to the latter if the internal unit is used on a standard - not VIP - PoE network 3. RJ45 Ethernet connector for connecting the internal unit to the VIP network 4. SD Card slot For wiring details, refer to the diagrams section at the end of this manual. We recommend using VIP Manager software Art. 1449 to configure the internal unit (see specific manual). However, the main parameters can also be configured directly, on the device itself (see page 62). 1. Connection terminals 2. VIP - POE selector for fitting to the latter if the internal unit is used on a standard - not VIP - PoE network 3. RJ45 Ethernet connector for connecting the internal unit to the VIP network 4. Optional buttons Art. 6332 For wiring details, refer to the diagrams section at the end of this manual. We recommend using VIP Manager software Art. 1449 to configure the internal unit (see specific manual). However, the main parameters can also be configured directly, on the device itself (see page 50).

GND AL CFP S-

S+ Floor door call contact terminal Alarm contact terminal Common terminal for alarm contact and floor door call Ringtone repetition terminals Easycom door-entry phone Art. 6203 VIP switchboard Art. 1952 1. Connection terminals 2. VIP - POE selector for fitting to the latter if the internal unit is used on a standard - not VIP - PoE network 3. RJ45 Ethernet connector for connecting the internal unit to the VIP network For wiring details, refer to the diagrams section at the end of this manual. Use VIP Manager software Art. 1449 to configure the internal unit (see specific manual). For wiring details, refer to the diagrams section at the end of this manual. We recommend using VIP Manager software Art. 1449 to configure the internal unit (see specific manual). However, the main parameters can also be configured directly, on the device itself (see page 67). Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 36/57 Vdc 3A Max. Dimensions H: 16 cm W: 9.1 cm D: 2.7 cm Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 36/57 Vdc 3A Max. The Easycom door-entry phone Art. 6203 manages up to 3 slave devices, not 15 as with other internal units.

Module designed for audio/video speaker units. Requires audio/video unit Art. 4662C to complete installation. Versions with 0, 1 and 2 buttons are

available. Additional call button module. Versions with 3, 4 and 6 buttons are available. VIP system audio-video unit with terminal block, complete with spherical lens adjustable colour camera. NC / NO: Door lock connection terminals COM: Common terminal DO: Door Open terminal RTE / -: Timed relay control terminals ~ ~: Power supply terminals TX- / TX+: Ethernet transmission line terminals RX- / RX+: Ethernet reception line terminals Technical characteristics Power supply 12 Vac Temperature thresholds -30 / +55°C Dimensions H: 10.2 cm W: 5.5 cm D: 3.5 cm Powercom series external units Powercom module Art. 3331/0 - 1 - 2 for audio/video units Powercom series colour audio/video unit for VIP system Art. 4662C Powercom call button module Art. 3337/3 - 4 - 6 For wiring details, refer to the diagrams section at the end of this manual. 1. 4-pole cable connector For wiring details, see page 28. 1

Backlit module with LEDs for various indications and additional 10 A relay.

Technical characteristics Power supply 12 Vac 3A Temperature thresholds -30 / +55°C Dimensions H: 8.9 cm W: 11.2 cm D: 4 cm Powercom series backlit indication module Art. 3327 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : Technical characteristics Power supply 12 Vac Temperature thresholds -30 / +55°C Dimensions H: 18 cm W: 11.2 cm D: 4 cm Digital call module complete with electronic directory with graphic LCD display. Also functions as a coded electronic key module. Names can be scrolled using the two search buttons or by entering the initial letter of the required name. Once the right name has been found, press the call button. The user code can also be entered to make a direct call. 1 ~ ~: Power supply terminals PR -: Programming terminals TX RX: RS232 line terminals (not used) -: RS232 line negative terminal (not used) D- D: RS485 data line N.B. Up to this point, the functions linked to the RS485 line have not been implemented. Powercom series digital call module for VIP system Art. 3370 For wiring details, see page 29. 1. 4-pole cable connector For wiring details, refer to the diagrams section at the end of this manual.

IKall series external units

Module preset for audio/video speaker units. Requires audio/video unit Art. 4682C to complete installation. Versions with 0, 1 and 2 buttons are available. IKall module Art. 33410 - 33411 - 33412 for audio/video units Module with facility for audio porter units. Requires audio unit Art. 1682 to complete installation. Versions with 0, 1 and 2 buttons are available. IKall module Art. 33400 - 33401 - 33402 for audio units Door-entry phone porter unit for VIP system, complete with terminal block. Technical characteristics Power supply 33 Vdc Temperature thresholds -30 / +55°C Dimensions H: 10.2 cm W: 5.5 cm D: 3.5 cm IKall series audio unit for VIP system Art. 1682 SE GND -V +V 1 SE: Door lock connection terminals NC / NO: Normally closed and normally open output terminals COM: Common terminal RTE / GND: Timed relay control terminals -V +V: Power supply terminals TX- / TX+: Ethernet transmission line terminals RX- / RX+: Ethernet reception line terminals For wiring details, refer to the diagrams section at the end of this manual. 1. 8-pole cable connector

24 Vac - 33 Vdc

Temperature thresholds -30 / +55°C Dimensions H: 18 cm W: 11.2 cm D: 4 cm GND 485 D+ S 24Vac 24Vac 485 D- PRG 1 24 Vac: Local power supply terminals (for use when a dedicated power supply unit needs to be connected for module Art. 3360A) PRG GND: Programming terminals 485 D- 485D+: RS485 data line VIP system audio-video unit with terminal block, complete with mini lens adjustable colour camera. Technical characteristics Power supply 33 Vdc Temperature thresholds -30 / +55°C Dimensions H: 10.2 cm W: 5.5 cm D: 3.5 cm IKall series colour audio/video unit for VIP system Art. 4682C SE GND -V +V 1 SE: Door lock connection terminals NC / NO: Normally closed and normally open output terminals COM: Common terminal RTE / GND: Timed relay control terminals -V +V: Power supply terminals TX- / TX+: Ethernet transmission line terminals RX- / RX+: Ethernet reception line terminals Additional call button module. Versions with 3, 4 and 6 buttons are available. IKall call button module Art. 33433 - 33434 - 33436 Digital call module complete with electronic directory with graphic LCD display. Also functions as a coded electronic key module. Names can be scrolled using the two search buttons or by entering the initial letter of the required name. Once the right name has been found, press the call button. The user code can also be entered to make a direct call. IKall series digital call module for VIP system Art. 3360A For wiring details, refer to the diagrams section at the end of this manual. 1. 8-pole cable connector For wiring details, see page 30. 1. 8-pole cable connector For wiring details, refer to the diagrams section at the end of this manual.

-30 / +55°C

Dimensions H: 18 cm W: 11.2 cm D: 4 cm D D- TX RX PR- S 12~~ ⁕ ~ 12~ - - Programming terminals NOT USED NOT USED Powercom power supply terminals NOT USED Vandalcom series external units Digital call module complete with electronic directory with graphic LCD display. Also functions as a coded electronic key module. The user code can be entered directly to make a call. Vandalcom series digital call module for VIP system Art. 3270, for Powercom external unit Art. 4662C D D- TX RX PR- S 12~~ ⁕ ~ 12~ - - Data connection terminal for the external unit NOT USED NOT USED Digital call module complete with electronic directory with graphic LCD display. Also functions as a coded electronic key module. The user code can be entered directly to make a call. Vandalcom series digital call module for VIP system Art. 3070B, for Powercom external units Art. 4662C and IKall external units Art. 4682C Technical characteristics Power supply 12 Vac - 33 Vdc Temperature thresholds -30 / +55°C Dimensions H: 18 cm W: 11.2 cm D: 4 cm D+ 485 D- 485 TX RX PR- S 12~ 12~ - - V+ V- Programming terminals Ikall power supply terminals Data connection terminal for the external unit Common terminal Common terminal D+ 485 D- 485 TX RX PR- S 12~ 12~ - - V+ V- NOT USED NOT USED NOT USED Powercom power supply terminals For wiring details, refer to the diagrams section at the end of this manual. For wiring details, refer to the diagrams section at the end of this manual.

-30 / +55°C

Dimensions H: 18 cm W: 11.2 cm D: 4 cm Digital call module complete with electronic directory with graphic LCD display. Name scrolling is carried out using two search buttons. Once the right name has been found, press the call button. Vandalcom series digital call module for VIP system Art. 3272, for Powercom external unit Art. 4662C D D- TX RX PR- S 12~~ ⁕ ~ 12~ - - Programming terminals. NOT USED NOT USED Powercom power supply terminals NOT USED D D- TX RX PR- S 12~~ ⁕ ~ 12~ - - Data connection terminal for the external unit NOT USED NOT USED Common terminal Digital call module complete with electronic directory with graphic LCD display. Name scrolling is carried out using two search buttons. Once the right name has been found, press the call button. Vandalcom series digital call module for VIP system Art. 3072B, for Powercom external units Art. 4662C and IKall external units Art. 4682C Technical characteristics Power supply 12 Vac - 33 Vdc Temperature thresholds -30 / +55°C Dimensions H: 18 cm W: 11.2 cm D: 4 cm D+ 485 D- 485 TX RX PR- S 12~ 12~ - - V+ V- Programming terminals Data connection terminal for the external unit Common terminal D+ 485 D- 485 TX RX PR- S 12~ 12~ - - V+ V- NOT USED NOT USED NOT USED Ikall power supply terminals Powercom power supply terminals For wiring details, refer to the diagrams section at the end of this manual. For wiring details, refer to the diagrams section at the end of this manual.

Module Art. 3268I/0 -1 - 2 designed for a/v units, iKall series

Module designed for audio/video porter units. Requires audio/video unit Art. 4682C to complete installation. Versions with 0, 1 and 2 buttons are available. Module Art. 3269/0 - 1 - 2 designed for a/v units, Powercom series Module preset for audio/video speaker units. Requires audio/video unit Art. 4662C to complete installation. Versions with 0, 1 and 2 buttons are available. Module Art. 3262I/0 -1 - 2 designed for audio units, IKall series Module with facility for audio porter units. Requires audio unit Art. 1682 to complete installation. Versions with 0, 1 and 2 buttons are available. Vandalcom series 4-button module Art. 3064/C for VIP system Module with 4 additional call buttons. For wiring details, see page 33. For wiring details, see page 33. For wiring details, see page 32. For wiring details, see page 34.

12 - 24 V DC power supply terminal

Earth terminal 1 2 3 5 4 2 3 5 4 1. Video signal from cameras input terminals 2. Secondary power supply terminals. To be used if the POE network power supply is insufficient Input terminal for composite video signal from camera 1 Input terminal for composite video signal from camera 2 Input terminal for composite video signal from camera 3 Input terminal for composite video signal from camera 4 Camera 1 shield terminal Camera 2 shield terminal Camera 3 shield terminal Camera 4 shield terminal VIP system accessories Remote camera module Art. 1445 Remote camera module Art. 1445 transmits the video signals received from 4 cameras. D+ D- GND Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 36/57 Vdc 3A Max. Temperature thresholds -30 / +55°C Dimensions 4 DIN modules / H: 3.6 cm W: 6.5 cm D: 8.3 cm N.B. Up to this point, the functions linked to the RS485 line have not been implemented. 4. RS485 line terminals. 3. Network connection Ethernet port. 5. RS485 line closure jumper Earth terminal RS485 data line For wiring details, refer to the diagrams section at the end of this manual.

Art. Sk9071 12 VDC power supply terminals

1 3 2 4 3 2 4 IO module Art. 1443 can be used to control 1 relay on board the device itself or on board any expansion units Art. SK9071 connected to it. Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 36/57 Vdc 3A Max. Temperature thresholds -30 / +55°C Dimensions 4 DIN modules / H: 3.6 cm W: 6.5 cm D: 8.3 cm 1. Terminal block for on-board relay inputs and output 2. Terminals for connection of expansion module Art. SK9071 3. Network connection Ethernet port 4. VIP - Standard POE power supply selector Input terminal 1 Open collector output terminal Common terminal for NC / NO Earth terminal Input terminal 2 On-board relay normally closed terminals Earth terminal Art. Sk9071 connection terminals On-board relay normally open terminals VIP system actuator relay module Art. 1443 For wiring details, refer to the diagrams section at the end of this manual.

Module Art. 1446 provides an outgoing video signal from the system in PAL or NTSC format.

Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 36/57 Vdc 3A Max. Temperature thresholds -30 / +55°C Dimensions 4 DIN modules / H: 3.6 cm W: 6.5 cm D: 8.3 cm 1. Terminal block for video outputs 3. Network connection Ethernet port S-VIDEO video output terminals CVBS video output terminals Terminal not used Terminal not used + - D+ D- A B Expansion module Art. SK9071 for use in conjunction with the IO module Art. 1443. Technical characteristics Absorption Min. 0.7 W Max. 2.6 W Power supply 12 Vdc Temperature thresholds -30 / +55°C Dimensions 8 DIN modules / H: 5.5 cm W: 14 cm D: 9.5 cm 1. Connection terminal blocks Terminals not used Art. 1443 connection terminals Art. 1443 12 VDC power supply terminals A B J1...J10 Relay output terminals PAL / NTSC video output module Art. 1446 Expansion module Art. SK9071 For wiring details, refer to the diagrams section at the end of this manual. For wiring details, refer to the diagrams section at the end of this manual. OUT 2 OUT 1 Generic open collector output terminal (in closure to GND) Terminal not used IN2 COM IN1 Terminal not used Terminal not used Terminal not used 2. Terminal block for open collector outputs 4. Input terminal block

Chapter 3: System preparation and specifications

Connection distances from power supply unit Art. 1395 / Art. 1595 to external unit The connection distance varies depending on the port used on Switch Art. 1440. Art. 1440 10 Mb 250 m Art. 1440 100 Mb 120 m Using the 10 Mb port Using the 100 Mb port The connection distance varies depending on the ports used on Switches Art. 1440. Art. 1440 10 Mb 250 m Art. 1440 10 Mb Art. 1440 10 Mb 250 m Art. 1440 100 Mb Art. 1440 100 Mb 250 m Art. 1440 10 Mb Art. 1440 100 Mb 120 m Art. 1440 100 Mb Connection distances Connection distances between external unit and Switch Art. 1440 Connection distances between 2 Switches Art. 1440 Art.1395 Art.1595 A Max 0,5 mm2 (Ø 0,8 mm - AWG 20) 10 m 25 m 0,5 mm2 (Ø 0,8 mm - AWG 20) Comelit Art. 4576-4578 10 m 25 m 1 mm2 (Ø 1,2 mm - AWG 17) 25 m 50 m 1 mm2 (Ø 1,2 mm - AWG 17) Comelit Art. 4577 / 4579 25 m 50 m 1 mm2 (Ø 1,2 mm - AWG 17) 25 m 50 m 1,5 mm2 (Ø 1,4 mm - AWG 15) 40 m 75 m 2,5 mm2 (Ø 1,8 mm - AWG 13) 60 m 100 m Art.1395 Art.1595

The connection distance varies depending on the port used on Switch Art. 1440.

Using the 10 Mb port Using the 100 Mb port Expanding a system using repeater Art. 1447 Repeaters Art. 1447 can be connected in series to increase the connection distance between two Switches Art. 1440 (Max. 8). The connection distance between a Switch and a Repeater varies depending on the port used on Switch Art. 1440. 250 m Art. 1440 Art. 1447 10 Mb 120 m Art. 1440 Art. 1447 100 Mb 120 m Art. 1447 Art. 1447 Art. 1447 120 m The connection distance between 2 Repeaters is always 120 m. See diagram VIP/005 Connection distances from Switch Art. 1440 / Repeater Art. 1447 to door-entry phones / door entry monitors Connection distances from Switch Art. 1440 / Repeater Art. 1447 to switchboard Art. 1952

Guide to fi tting a UTP / STP RJ45 Direct network cable

The recommended cables are: • UTP (Unshielded Twisted Pair): not protected from electromagnetic interference, maximum length 100 metres. We recommend the use of a Panduit cable code NUL5C04BU-CE. • STP (Shielded Twisted Pair): similar to the UTP but with a metal sheath. The UTP and STP can fall into various categories. Category 5 (CAT 5) cables or greater must be used for the VIP system. • Crimping pliers 6-P 8-P. We recommend using 8-pole Panduit pliers code MPT5-8A. • Tester for RJ45 cables. The tester must only be used while the system is off The tools required for fi tting are as follows: • 2 RJ45 connectors for each section of cable. We recommend using Panduit connectors code MP588-L.

1. Most crimping pliers have two pairs of blades, one pair on one side to strip the wires and another pair on the other side to cut the wires. If the pliers do

not allow you to cut the cable sheath, you should use a blade and cut the sheath with it, removing a length of about three centimetres. Be especially careful not to cut or scratch the wires inside the sheath; once cut, most sheaths break if they are folded or pulled. 2. When you have removed the sheath, you will have four pairs of wires, twisted together two by two and of different colours. Untwist the wire pairs so you have 8 separate wires, but make sure you mark them if they are not of different colours (in some cables, the white/colour wires are completely white). 3. Spread the wires out into a fan, in the order in which you need to crimp them from left to right. The cable configuration is illustrated in Table 1 and Figure A. Table 1 Connector 1 Connector 2 White / Orange White / Orange Orange Orange White / Green White / Green Blue Blue White / Blue White / Blue Green Green White / Brown White / Brown Brown Brown N.B.: if the cable colours are different, simply maintain the correct correspondences FIGURE A 30mm 1 20mm 1 20 1 20 4. Hold the wires tightly between two fingers and flatten them so that they are side by side, then straighten them by pulling them taut with your fingers to remove slight curves caused by the previous twisting. Make sure they stay in the correct order. 5. Continuing to hold them taut, trim the excess by 2 centimetres, so that they are all the same length. 30mm 20mm

6. Insert the wires into the RJ45 connector, still holding them tightly between your fingers. The connector tab should be facing downwards and not

visible. The insulating sheath should just reach the edge of the connector. 7. Make sure the wires are fully inserted by inspecting the side of the transparent connector. Next, insert the connector into the crimping pliers and, using both hands, crimp the connector so as to secure the wires. The pliers should not open if they did not close fully. 8. Now repeat steps 1 to 7 above, to crimp the cable on the other side. Complete connector example

Chapter 4: Mounting external units and internal units

Mac Address VIP Address Description 00252900082B 00002001 South gate external unit 00252900086C 00002002 North gate external unit 00252900023R 00000139 Apartment 1 internal unit 00252900052A 00000127 Smith apartment internal unit During the installation of various products, we recommend a document is compiled to keep track of the location of the device within the system. An example of how to compile such a document is provided below: For all products, the VIP address is programmed using VIP Manager software Art. 1449, with the exception of monitors Art. 6202, Art. 6304, Art. 6501 and Art. 1952, which can be used to set the VIP address, even locally. The Mac address for the product is indicated by a label on the packaging box and another label applied directly to the product itself.

3337/3 - 4 - 6

7 4662C 4662C 360û 360° 5 4 2 3 3337/3 - 4 - 6 8 4662C 4662C 3331/0-1-2 3331/0-1-2 360û 2 1 3 360° 5 4 2 3 1 3337/3 - 4 - 6 9 Mounting Powercom series external units Mounting external unit Art. 4662C and additional buttons Art. 3337/3 - 4 - 6 4662C 4662C 3331/0-1-2 3331/0-1-2 360û 2 1 3 360° 5 4 2 3 1 3337/3 - 4 - 6 1 4662C 4662C 3331/0-1-2 3331/0-1-2 360û 2 1 3 360° 5 4 2 3 1 3337/3 - 4 - 6 2 4662C 4662C 3331/0-1-2 3331/0-1-2 360û 2 1 3 360° 5 4 2 3 1 3337/3 - 4 - 6 3 4662C 4662C 3331/0-1-2 3331/0-1-2 360û 1 360° 5 4 2 3 1 3337/3 - 4 - 6 4 4662C 4662C 3331/0-1-2 3331/0-1-2 360û 2 1 3 360° 5 4 2 3 1 3337/3 - 4 - 6 5 4662C 4662C 3331/0-1-2 3331/0-1-2 360û 2 1 3 360° 5 4 2 3 1 3337/3 - 4 - 6 6 OPTIONAL

Mounting actuator module Art. 3327

1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : 360û 360° 2 1 3 PR TX RX 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : PR TX RX 1 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : 360û 360° 2 1 3 PR TX RX 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : PR TX RX 2 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : 360û 360° 2 1 3 PR TX RX 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : PR TX RX 3 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : 360û 360° 2 1 3 PR TX RX 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : PR TX RX 4 Mounting digital directory Art. 3370 NC C NO LP LP 360û 360° 2 1 3 1 NC C NO LP LP 360û 360° 2 1 3 2 NC C NO LP LP 360û 360° 2 1 3 4 NC C NO LP LP 360û 360° 2 1 3 3

Mounting IKall series external units

Mounting external unit Art. 4682C and additional buttons Art. 33433 - 33434 - 33436 33410 33411 33412 4682C 4682C 3 5 2 1 4 33433 33434 33436 33410 33411 33412 6 3 2 1 4 8 3 2 1 33410 33411 33412 4682C 33433 33434 33436 4682C 1 3 2 1 33410 33411 33412 4682C 3 1 33433 33434 33436 33410 33411 33412 4682C 2 C 4682C 3 5 2 1 4 33 34 36 33410 33411 33412 3 3 2 1 4682C 4 3 2 1 4682C 5 33410 33411 33412 4682C 4682C 3 5 2 1 4 33433 33434 33436 33410 33411 33412 7 OPTIONAL

Mounting digital directory Art. 3360A

360° 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : 360û 360° 2 1 3 PR TX RX PR TX RX PR TX RX 2 1 3 PR TX RX 1 360° 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : 360û 360° 2 1 3 PR TX RX 2 1 3 PR TX RX 2 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : PR TX RX PR TX RX 3 360° 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 PQRS 7 T U V 8WXYZ 9 X 0 . , : 360û 360° 2 1 3 P 2 1 3 PR TX RX 4

Connecting audio-video unit Art. 4662C for use with buttons on Vandalcom external unit

Art. 3269/1 - 2 Mounting Vandalcom series external units Only applies to Art. 4662C Art. 2G60000120 included in Art. 4662C package Art. 2G60000616 = black ALTO ALTO black orange blue black 3269/2 3269/2 4662C 4662C 4662C 4662C 2 black blue orange ALTO ALTO black orange blue black 3269/2 3269/2 4662C 4662C 4662C 4662C 3 black ALTO ALTO black orange blue black 3269/2 3269/2 4662C 4662C 4662C 4662C 1 black blue orange ALTO ALTO orange blue 3269/2 3269/2 4662C 4662C 4662C 5 black blue orange ALTO ALTO black orange blue black 3269/2 3269/2 4662C 4662C 4662C 4662C 4

Connecting audio unit 1682 or audio-video unit Art. 4682C for use with buttons on Vandalcom

external unit Art. 3262I/1 - 2 and Art. 3268I/1 - 2 orange orange ALTO ALTO ALTO white green orange 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 3262I/2 3268I/2 2 orange white green white green orange ALTO ALTO ALTO white green orange ALTO 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 3262I/2 3268I/2 3262I/2 3268I/2 3 ALTO ALTO ALTO white green orange 4682C 1682 4682C 1682 4682C 1682 4682C 1682 3262I/2 3268I/2 1 orange white green white green orange ALTO ALTO ALTO white green orange ALTO 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 3262I/2 3268I/2 3262I/2 3268I/2 2 orange white green white green orange ALTO ALTO ALTO white green orange ALTO 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 3262I/2 3268I/2 3262I/2 3268I/2 3 orange ALTO ALTO ALTO white green orange 1682 4682C 1682 4682C 1682 3262I/2 3268I/2 1

Mounting audio-video unit Art. 4662C or 4682C for use with additional buttons Art. 3064/C

2 3 1 5 4 6

Mounting digital directories Art. 3270 - 3272 with Powercom external unit Art. 4662C

Vandalcom digital directories Art. 3270 and Art. 3272 can only be connected with Powercom external unit Art. 4662C Art. 4662C Art. 3270 Art. 3272 - S 12 12 ~ ~ ~ ~ * - PR 1 Art. 4662C Art. 3270 Art. 3272 - S 12 12 ~ ~ ~ ~ * - PR 2 Art. 4662C Art. 3270 Art. 3272 - S 12 12 ~ ~ ~ ~ * - PR 3 Art. 4662C - S - PR 6 Art. 4662C Art. 3270 Art. 3272 - S 12 12 ~ ~ ~ ~ * - PR 4 Art. 4662C Art. 3270 Art. 3272 - S 12 12 ~ ~ ~ ~ * - PR 5

Mounting digital directories Art. 3070B - 3072B with IKall external unit Art. 4682C

Vandalcom digital directories Art. 3070B and Art. 3072B can be connected with both IKall external unit Art. 4682C and Powercom external unit Art. 4662C. For mounting with external unit Art. 4662C, see page 34 Art. 3070B Art. 3072B Art. 4682C 4682C V+ S V- 1 Art. 3070B Art. 3072B Art. 4682C 4682C S V- 2 Art. 3070B Art. 3072B Art. 4682C 4682C V+ S V- 3 Art. 3070B Art. 3072B Art. 4682C 4682C S V- 4 Art. 3070B Art. 3072B Art. 4682C 4682C 3 Art. 3070B Art. 3072B Art. 4682C 4682C V+ S V- 4

Mounting internal units

Mounting Planux monitor Art. 6202 with flush-mounted box Art. 6117 ALTO UP HAUT OBEN 14,5 cm 14,5 cm 1 2 2 3 145-150 cm 115-125 cm ALTO UP HAUT OBEN 4,5 cm 14,5 cm 1 2 2 3 145-150 cm 115-125 cm 2 3 4 5 1 145-150 cm 115-125 cm ALTO UP HAUT OBEN 14,5 cm 14,5 cm 1 2 2 3 145-150 cm 115-125 cm 2 3 4 5 1 1 3 2 ALTO UP HAUT OBEN 1 2 2 3 1 2 3 4 5 6 2 3 4 5 1 145-150 cm 115-125 cm 2 3 4 5 1 7 8

Mounting Planux monitor Art. 6202 with wall bracket Art. 6120

145-150 cm 115-125 cm 145-150 cm 115-125 cm 145-150 cm 115-125 cm 145-150 cm 115-125 cm 145-150 cm 115-125 cm 1 2 3 4 5 6 145-150 cm 115-125 cm 145-150 cm 115-125 cm 7 8 9

Mounting Sette Stelle monitor Art. 6501

23 cm 16,7 cm 150 cm 23 cm 16,7 cm 150 cm 23 cm 16,7 cm 150 cm 23 cm 16,7 cm 150 cm 1 2 3 4 23 cm 16,7 cm 150 cm 5

Mounting Easycom monitor Art. 6203

2 1 2 CLICK ! 3 3 16 cm 9 cm 2,8 cm 115 - 125 cm 140 - 145 cm 2 1 2 CLICK ! 3 3 16 cm 9 cm 2,8 cm 115 - 125 cm 140 - 145 cm 2 1 2 CLICK ! 3 3 16 cm 9 cm 2,8 cm 115 - 125 cm 140 - 145 cm 2 1 2 CLICK ! 3 3 16 cm 9 cm 2,8 cm 115 - 125 cm 140 - 145 cm 2 1 2 CLICK ! 3 3 16 cm 9 cm 2,8 cm 115 - 125 cm 140 - 145 cm 2 1 2 CLICK ! 3 3 16 cm 9 cm 2,8 cm 115 - 125 cm 140 - 145 cm 1 2 3 4 5 6 2 1 2 CLICK ! 3 3 16 cm 9 cm 2,8 cm 115 - 125 cm 140 - 145 cm 7

Mounting Smart monitor Art. 6304 with wall bracket Art. 6320

13,8 cm 13,8 cm 160 cm 130 cm Lmax = 7 cm Lmin = 6,5 cm 1 2 1 2 2 2 1 13,8 cm 13,8 cm 160 cm 130 cm Lmax = 7 cm Lmin = 6,5 cm 1 2 1 1 2 2 1 2 2 1 1 m 160 cm 130 cm Lmax = 7 cm Lmin = 6,5 cm 1 2 2 1 1 130 c Lmax = 7 cm Lmin = 6,5 cm 1 2 2 2 1 1 1 130 c Lmax = 7 cm Lmin = 6,5 cm 1 1 2 2 2 1 1 13,8 cm 13,8 cm 160 cm 130 cm Lmax = 7 cm Lmin = 6,5 cm 1 2 1 2 1 2 2 1 2 2 1 1 1 2 3 4 5 6 1 2 1 2 1 2 1 2 2 1 2 2 1 7 8 13,8 cm 13,8 cm 160 cm 130 cm Lmax = 7 cm Lmin = 6,5 cm 1 2 1 2 1 2 2 1 2 2 1 1 9

Mounting Smart monitor Art. 6304 with flush-mounted box Art. 6117

Lmax = 10 cm ALTO UP HAUT OBEN 2 3 4 5 1 160 cm 130 cm 13,8 cm 13,8 cm 1 2 Lmin = 6 cm 2 1 2 1 2 1 Lmax = 10 cm ALTO UP HAUT OBEN 2 3 4 5 1 160 cm 130 cm Lmin = 6 cm 2 ALTO UP HAUT OBEN 16 130 cm Lmax = 10 cm 2 3 4 5 1 Lmin = 6 cm 1 2 1 2 1 2 1 1 2 2 Lmax = 10 cm ALTO UP HAUT OBEN 2 3 4 5 1 160 cm 130 cm Lmin = 6 cm 1 2 1 2 1 Lmax = 10 cm ALTO UP HAUT OBEN 2 3 4 5 1 160 cm 130 cm 13,8 cm 13,8 cm 1 2 Lmin = 6 cm 1 2 1 2 3 4 5 6 1 2 1 2 1 1 2 2 1 1 2 1 1 2 2 7 8 Lmax = 10 cm 2 3 4 5 1 Lmin = 6 cm 1 2 1 2 1 2 1 1 2 2 9 0 cm 6 cm 1 2 2 1 2 1 1 2 2 10

Chapter 5: Installation programming

Every VIP product is identified by the factory with a unique code called the Mac address. The Mac address for the product is indicated by a label on the packaging box and another label applied directly to the product itself. Mac Address VIP Address * Description 00252900082B 00002001 South gate external unit 00252900086C 00002002 North gate external unit 00252900023R 00000139 Apartment 1 internal unit 00252900052A 00000127 Smith apartment internal unit Each system device must be programmed with a different code, called the VIP address. The VIP address is an 8-digit code identifying each extension and can be entered as desired, without following any pre-set sequence. However, we recommend using a logic diagram to keep track of the addresses entered. A logic diagram (optional) for entering the VIP address is provided below. Example: Building/staircase/floor/apartment • 01041156 • 00021022 • 01001223 • 01030009 • 00000012 VIP code Mac Address During the installation of various products, we recommend a document is compiled to keep track of the location of the device within the system. An example of how to compile such a document is provided below: * For all products, the VIP address is programmed using VIP Manager software Art. 1449, with the exception of monitors Art. 6202 and Art. 5900, which can be used to set the VIP address, even locally. Reset procedure for external unit Art. 4662C and 4682C 1. Cut off the power supply to the external unit. 2. Enable programming mode by moving the relevant slider. 3. Set the dip switch activation code: dip switches 1-2-3 to ON, the other dip switches to OFF. 4. Restore the power supply to external unit. 5. The external unit will now beep twice to request the confirmation code. 6. Set the dip switch confirmation code: dip switches 1-2-3 to OFF, the other dip switches to ON (i.e. the opposite of the activation code). 7. Exit programming mode by moving the relevant slider. 8. The external unit will now beep for 2-3 seconds to indicate that the configuration has been reset. 9. When the beep has ended, the external unit will start up with its factory set configuration values.

Dip switch ON

Nome / Name Codice / Code Dip switch ON Nome / Name Codice / Code Dip switch ON Nome / Name Codice / Code Dip switch ON Nome / Name 1 1 65 1.7 129 1.8 193 1,7,8 2 2 66 2.7 130 2.8 194 2,7,8 3 1.2 67 1,2,7 131 1,2,8 195 1,2,7,8 4 3 68 3.7 132 3.8 196 3,7,8 5 1.3 69 1,3,7 133 1,3,8 197 1,3,7,8 6 2.3 70 2,3,7 134 2,3,8 198 2,3,7,8 7 1,2,3 71 1,2,3,7 135 1,2,3,8 199 1,2,3,7,8 8 4 72 4.7 136 4.8 200 4,7,8 9 1.4 73 1,4,7 137 1,4,8 201 1,4,7,8 10 2.4 74 2,4,7 138 2,4,8 202 2,4,7,8 11 1,2,4 75 1,2,4,7 139 1,2,4,8 203 1,2,4,7,8 12 3.4 76 3,4,7 140 3,4,8 204 3,4,7,8 13 1,3,4 77 1,3,4,7 141 1,3,4,8 205 1,3,4,7,8 14 2,3,4 78 2,3,4,7 142 2,3,4,8 206 2,3,4,7,8 15 1,2,3,4 79 1,2,3,4,7 143 1,2,3,4,8 207 1,2,3,4,7.8 16 5 80 5.7 144 5.8 208 5,7,8 17 1.5 81 1,5,7 145 1,5,8 209 1,5,7,8 18 2.5 82 2,5,7 146 2,5,8 210 2,5,7,8 19 1,2,5 83 1,2,5,7 147 1,2,5,8 211 1,2,5,7,8 20 3.5 84 3,5,7 148 3,5,8 212 3,5,7,8 21 1,3,5 85 1,3,5,7 149 1,3,5,8 213 1,3,5,7,8 22 2,3,5 86 2,3,5,7 150 2,3,5,8 214 2,3,5,7,8 23 1,2,3,5 87 1,2,3,5,7 151 1,2,3,5,8 215 1,2,3,5,7.8 24 4.5 88 4,5,7 152 4,5,8 216 4,5,7,8 25 1,4,5 89 1,4,5,7 153 1,4,5,8 217 1,4,5,7,8 26 2,4,5 90 2,4,5,7 154 2,4,5,8 218 2,4,5,7,8 27 1,2,4,5 91 1,2,4,5,7 155 1,2,4,5,8 219 1,2,4,5,7.8 28 3,4,5 92 3,4,5,7 156 3,4,5,8 220 3,4,5,7,8 29 1,3,4,5 93 1,3,4,5,7 157 1,3,4,5,8 221 1,3,4,5,7.8 30 2,3,4,5 94 2,3,4,5,7 158 2,3,4,5,8 222 2,3,4,5,7.8 31 1,2,3,4,5 95 1,2,3,4,5.7 159 1,2,3,4,5.8 223 1,2,3,4,5,7,8 32 6 96 6.7 160 6.8 224 6,7,8 33 1.6 97 1,6,7 161 1,6,8 225 1,6,7,8 34 2.6 98 2,6,7 162 2,6,8 226 2,6,7,8 35 1,2,6 99 1,2,6,7 163 1,2,6,8 227 1,2,6,7,8 36 3.6 100 3,6,7 164 3,6,8 228 3,6,7,8 37 1,3,6 101 1,3,6,7 165 1,3,6,8 229 1,3,6,7,8 38 2,3,6 102 2,3,6,7 166 2,3,6,8 230 2,3,6,7,8 39 1,2,3,6 103 1,2,3,6,7 167 1,2,3,6,8 231 1,2,3,6,7.8 40 4.6 104 4,6,7 168 4,6,8 232 4,6,7,8 41 1,4,6 105 1,4,6,7 169 1,4,6,8 233 1,4,6,7,8 42 2,4,6 106 2,4,6,7 170 2,4,6,8 234 2,4,6,7,8 43 1,2,4,6 107 1,2,4,6,7 171 1,2,4,6,8 235 1,2,4,6,7.8 44 3,4,6 108 3,4,6,7 172 3,4,6,8 236 3,4,6,7,8 45 1,3,4,6 109 1,3,4,6,7 173 1,3,4,6,8 237 1,3,4,6,7.8 46 2,3,4,6 110 2,3,4,6,7 174 2,3,4,6,8 238 2,3,4,6,7.8 47 1,2,3,4,6 111 1,2,3,4,6.7 175 1,2,3,4,6.8 239 1,2,3,4,6,7,8 48 5.6 112 5.67 176 5,6,8 240 5,6,7,8 49 1,5,6 113 1,5,6,7 177 1,5,6,8 241 1,5,6,7,8 50 2,5,6 114 2,5,6,7 178 2,5,6,8 242 2,5,6,7,8 51 1,2,5,6 115 1,2,5,6,7 179 1,2,5,6,8 243 1,2,5,6,7.8 52 3,5,6 116 3,5,6,7 180 3,5,6,8 244 3,5,6,7,8 53 1,3,5,6 117 1,3,5,6,7 181 1,3,5,6,8 245 1,3,5,6,7.8 54 2,3,5,6 118 2,3,5,6,7 182 2,3,5,6,8 246 2,3,5,6,7.8 55 1,2,3,5,6 119 1,2,3,5,6.7 183 1,2,3,5,6.8 247 1,2,3,5,6,7,8 56 4,5,6 120 4,5,6,7 184 4,5,6,8 248 4,5,6,7,8 57 1,4,5,6 121 1,4,5,6,7 185 1,4,5,6,8 249 1,4,5,6,7.8 58 2,4,5,6 122 2,4,5,6,7 186 2,4,5,6,8 250 2,4,5,6,7.8 59 1,2,4,5,6 123 1,2,4,5,6.7 187 1,2,4,5,6.8 251 1,2,4,5,6,7,8 60 3,4,5,6 124 3,4,5,6,7 188 3,4,5,6,8 252 3,4,5,6,7.8 61 1,3,4,5,6 125 1,3,4,5,6.7 189 1,3,4,5,6.8 253 1,3,4,5,6,7,8 62 2,3,4,5,6 126 2,3,4,5,6.7 190 2,3,4,5,6.8 254 2,3,4,5,6,7,8 63 1,2,3,4,5.6 127 1,2,3,4,5,6,7 191 1,2,3,4,5,6,8 255 1,2,3,4,5,6,7.8 64 7 128 8 192 7.8 Dip switch programming table EXAMPLE setting code 200.

Manually programming buttons on external unit Art. 4662C

1. Perform the wiring for the external unit. 2. Power up the external unit, carry out steps (1-4). Set the Dip switch on the rear of the module Art. 4662C with the same code assigned to the internal unit, in accordance with the information provided in the programming table on page 45. The following procedure can be used to program buttons with VIP codes in the range between 1 and 255 only. To program higher VIP addresses, use VIP Manager software Art. 1449. PR PR PR 1 2 4 PR 3

Manually programming buttons on external unit Art. 4682C

1. Perform the wiring for the external unit. 2. Power up the external unit, carry out steps (1-4). Set the Dip switch on the rear of the module Art. 4682C with the same code assigned to the internal unit, in accordance with the information provided in the programming table on page 45. The following procedure can be used to program buttons with VIP codes in the range between 1 and 255 only. To program higher VIP addresses, use VIP Manager software Art. 1449. PR PR 1 2 PR 3 PR 4

Assigning module index to additional button products

Art. 3337/3 - 4 - 6 1. Perform module and button wiring. 2. Power up the external unit, carry out steps (1-4). Set the Module index code using the dip switches, see table on page 45. Follow the procedure below for each module Art. 3337 connected to the system. Make a note of the address which has just been set on module Art. 3337 and the VIP address of the external unit to which it is connected, as in the following example. Art. 4662C VIP address Art. 3337 Module index 00000600 236 This procedure is used to assign an index to modules Art. 3337. The module index must then be used with the VIP Manager software to complete module programming (see manual for VIP Manager software Art. 1449). PR PR PR 1 2 4 PR 3

Assigning module index to additional button products

Art. 33433 - 33434 - 33436 1. Perform module and button wiring. 2. Power up the external unit, carry out steps (1-4). Set the Module index code using the dip switches, see table on page 45. Follow the procedure below for each module Art. 3343 connected to the system. Make a note of the address which has just been set on module Art. 3337 and the VIP address of the external unit to which it is connected, as in the following example. Art. 4682C VIP address Art. 3337 Module index 00000600 236 This procedure is used to assign an index to modules Art. 3343. The module index must then be used with the VIP Manager software to complete module programming (see manual for VIP Manager software Art. 1449). PR PR PR 1 2 4 PR 3

1. Press button

and select the Settings menu using buttons , . SETTINGS MENU Installer menu ENTER PASSWORD 1 2 3 4 5 6 7 8 9 0 C ENTER PASSWORD 1 2 3 4 5 6 7 8 9 0 C **** ENTER PASSWORD 1 2 3 4 5 6 7 8 9 0 C **** 2. Press button to access and select the Installer menu using buttons , . 3. Press to access it. 4. Select the digits using , and enter by pressing . 5. When you have fi nished entering digits, select the icon . The password for the installer menu is 0000. The password cannot be changed. • Accessing the installer menu Programming internal units We recommend using VIP Manager software Art. 1459 to program the internal units. However, the main parameters of some internal units (Planux, 7Stelle, Smart and CPS) can be set directly on the product itself, where necessary. Planux monitor Art. 6202 and Smart monitor Art. 6304 (only with optional buttons Art. 6332) • Setting the menu language 1. Access the installer menu. 2. Select the Set language menu using buttons , . INSTALLER MENU Set language 3. Press to access it. LANGUAGES MENU Italiano English Franḉais Español Português Deutsch 4. Select the language using , and set by pressing . 5. Press to exit and save the changes.

1. Access the installer menu.

2. Select the Confi gure monitor menu using buttons , . 3. Press to access it. 4. Press button to access the VIP address menu. 5. Change the address using buttons , . Use buttons , to pass from one digit to the next. INSTALLER MENU Configure monitor • Programming the VIP code for main Planux monitors CONFIGURE MONITOR Reset configuration About ViP address CONFIGURE VIP ADDRESS ViP address 0 Master Slave 0 0 Left Right 0 0 0 0 0 0 1 1. Access the installer menu. 2. Select the Confi gure monitor menu using buttons , . 3. Press to access it. 4. Press button to access the VIP address menu. 5. Set the logic address for the main monitor in the same residential unit using buttons , . Use buttons , to pass from one digit to the next. 6. Move over the Slave option using buttons , and press to confi rm. 7. Move over the Slave address option using buttons , and change the address using buttons , . INSTALLER MENU Configure monitor CONFIGURE MONITOR Reset configuration About ViP address • Programming the VIP code for secondary Planux monitors CONFIGURE VIP ADDRESS ViP address 0 Master Slave 0 0 Left Right 0 0 0 0 0 0 1 CONFIGURE VIP ADDRESS ViP address 0 Master Slave 0 0 Left Right 0 0 0 0 0 0 1 CONFIGURE VIP ADDRESS ViP address 0 Master Slave 0 1 Left Right 0 0 0 0 0 0 1

If the Self-ignition function is selected:

CONFIGURE SELF-IGNITION Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Edit 1. Press the button. 2. Press to activate the function. Left Right CONFIGURE SELF-IGNITION Active: Automatic camera Camera number ViP address 0 0 0 0 0 0 0 0 1 3. Select the fi elds which can be changed using , and change the value using , or . If the Alarm function is selected: 1. Select the type of call you wish to assign to the button using , and press to confi rm. Alarms Alarm Panic Fire Priority call 4 For call confi guration, see page 54. If you press the button a priority call will be sent to the confi gured VIP address. • Confi guring 1 - 2 or Self-ignition buttons 1. Access the installer menu. 2. Select the Confi gure buttons menu by pressing , and press to access it. INSTALLER MENU Configure buttons 3. Select the Confi gure Self-Ignition menu by pressing , and press to access it. BUTTON PROGRAMMING MENU Configure Self-Ignition 1 2 CONFIGURE SELF IGNITION Intercom Self-ignition Alarms Edit Lock-release Actuator Activate output Function disabled 4. Select the function you wish to assign to the button using , and press to confi rm. 5. Once the desired function has been selected, press to change the settings. If the Intercom function is selected: CONFIGURE VIP ADDRESS 0 0 0 0 0 1 0 1 ViP address: Left Right Slave Master Backplate: 1 Active: f Select the fi elds which can be changed using , and change the value using , or . • The VIP address function determines the address of the internal unit to be called once the button is pressed. • The Backplate function determines whether to call the main or secondary internal unit with the same VIP address. 1 - 2 and Self-ignition buttons are programmed in the same way and can perform the same functions. The programming procedure, which applies to all 3 buttons, is described below. • The VIP address function determines the address of the external unit or remote camera module Art. 1445. • Select the Automatic camera function to link the camera for external unit Art. 4662C. • Select the Camera number function and enter the input number from the 4 available when using a remote camera module Art. 1445.

If the Lock-release function is selected:

1. Select the mode for which you wish to change the function using , and press to confi rm. CONFIGURE RELAY Configuration at rest time Configuration during call 2. Select the fi elds which can be changed using , and change the value using , or . RELAY DURING CALL Door 0 0 0 0 0 0 0 0 Interlocutor Active: Left Right Relay 1 Door 0 0 0 0 0 0 0 0 Interlocutor Active: Relay 1 • Confi guring the key button 1. Access the installer menu. INSTALLER MENU Configure buttons 2. Select the Confi gure buttons menu by pressing , and press to access it. 3. Press to access it. CONFIGURE BUTTONS Configure key button 1 2 4. Select the mode for which you wish to change the function using , and press to confi rm. CONFIGURE RELAY Configuration at rest time Configuration during call 5. Select the fi elds which can be changed using , and change the value using , or . RELAY DURING CALL Door 0 0 0 0 0 0 0 0 Interlocutor Active: Left Right Relay 1 Door 0 0 0 0 0 0 0 0 Interlocutor Active: Relay 1 6. Press to exit and save the changes. ACTUATOR SETTING 0 0 0 0 0 1 0 1 ViP address: Left Right Output Module 255 Active: 0 1 If the Actuator function is selected: • The VIP address fi eld identifi es actuator module Art. 1443. • In the Module fi eld, select whether to activate the relays on board the module (255) or those on the expansion module Art. SK9071 connected to it (1 to 10). • In the Output fi eld, select the relay you intend to activate. 1 or 2 if you enter 255 in the module fi eld. 1 to 10 if you enter an expansion module in the module fi eld. If the Activate Output function is selected: The button will control an NC/NO output which can be programmed as monostable or bistable. For output confi guration, see page 56.

• Confi guring the intercom directory

1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Press button to access the Call menu. SPECIAL SETTINGS MENU Alarms Door open Self-ignition Call Set ringtone repetition Set call times 4. Press button to access the Intercom Directory menu. CALL Intercom Directory 5. Press the button. INTERCOM CALLS DIRECTORY Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Edit 6. Press button to access the Confi gure name menu. CONFIGURE DIRECTORY Configure ViP address Configure name • Confi guring the Privacy / Doctor button 1. Access the installer menu. INSTALLER MENU Configure buttons 2. Select the Confi gure buttons menu by pressing , and press to access it. 3. Select the Confi gure Privacy/Doctor menu by pressing , and press to access it. CONFIGURE BUTTONS Configure Privacy/Doctor 1 2 4. Select the function you wish to assign to the button using , and press to confi rm. CONFIGURE PRIVACY / DOCTOR Doctor mode Privacy Doctor + privacy mode 5. Press to exit and save the changes. The Privacy function disables the ringtone for calls from the external unit and intercom. The Doctor function, as well as disabling the door-entry phone ringtone in the same way as the Privacy function, also enables automatic activation of the lock-release in response to a call from the external unit.

7. Enter the desired name using buttons

, to change the letters, , to move right or left and to delete. EDIT ENTRY Configure Name S M I T H Left Right Edit 8. Press button to return to the previous menu. CONFIGURE DIRECTORY Configure ViP address Configure name 9. Select the Confi gure VIP address menu by pressing , and press to access it. CONFIGURE VIP ADDRESS 0 0 0 0 0 1 0 1 ViP address: Left Right Slave Master Backplate: 1 Active: 10. Select the fi elds which can be changed using , and change the value using , or . • The VIP address function determines the address of the internal unit to be called once the button is pressed. • The Backplate function determines whether to call the main or secondary internal unit with the same VIP address. 11. Press to exit and save the changes. • Confi guring the self-ignition directory 1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Self-ignition menu by pressing , and press to access it. SPECIAL SETTINGS MENU Alarms Door open Self-ignition Call Set ringtone repetition Set call times 4. Press button to access the Camera directory menu. SELF-IGNITION Camera directory 5. Press the button. CAMERA DIRECTORY Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Edit 6. Press button to access the Confi gure name menu. CONFIGURE DIRECTORY Configure ViP address Configure name

• Confi guring the Actuator Directory

1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Actuator menu by pressing , and press to access it. SPECIAL SETTINGS MENU Door open Actuator Self-ignition Call Alarms Set ringtone repetition 4. Press the button. 5. Press button to access the Confi gure name menu. ACTUATOR DIRECTORY Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Edit 6. Enter the desired name using buttons , to change the letters, , to move right or left and to delete. CONFIGURE DIRECTORY Configure ViP address Configure name EDIT ENTRY Configure Name Left Right Edit S o u t h g a t e 7. Enter the desired name using buttons , to change the letters, , to move right or left and to delete. EDIT ENTRY Configure Name S M I T H Left Right Edit CONFIGURE DIRECTORY Configure ViP address Configure name CONFIGURE VIP ADDRESS 0 0 0 0 0 1 0 1 ViP address: Left Right Camera number Automatic camera 1 8. Press button to return to the previous menu. 9. Select the Confi gure VIP address menu by pressing , and press to access it. 10. Select the fi elds which can be changed using , and change the value using , or . • The VIP address functions determines the address of external unit Art. 4662C or remote camera module Art. 1445. • Select the Automatic camera function to link the camera for external unit Art. 4662C. • Select the Camera number function and enter the input number from the 4 available when using a remote camera module Art. 1445. 11. Press to exit and save the changes.

8. Select the Confi gure VIP address menu by pressing

, and press to access it. CONFIGURE DIRECTORY Configure ViP address Configure name 9. Select the fi elds which can be changed using , and change the value using , or . ACTUATOR SETTING 0 0 0 0 0 1 0 1 ViP address: Left Right Output Module 255 Active: 0 1 10. Press to exit and save the changes. • The VIP address fi eld identifi es actuator module Art. 1443. • In the Module fi eld, select whether to activate the relays on board the module (255) or those on the expansion module Art. SK9071 connected to it (1 to 10). • In the Output fi eld, select the relay you intend to activate: 1 or 2 if you enter 255 in the module fi eld, or 1 to 10 if you enter an expansion module in the module fi eld. 7. Press button to return to the previous menu. • Setting the Door Open function The function can be used to monitor the input of an external unit programmed with the Door Open function. When the input is opened or closed the key LED on the monitor lights up to indicate that the door is open. 1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Door open menu by pressing , and press to access it. SPECIAL SETTINGS MENU Actuator Self-ignition Call Alarms Set ringtone repetition Door open 4. Press the button. DOOR OPEN Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Edit 5. Select the fi elds which can be changed using , and change the value using , or . • The VIP address fi eld identifi es the external unit you wish to monitor. CONFIGURE VIP ADDRESS 0 0 0 0 0 1 0 1 ViP address: Left Right Active: 6. Press to exit and save the changes.

1. Access the installer menu.

2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Set ringtone repetition menu by pressing , and press to access it. SPECIAL SETTINGS MENU Alarms Door open Self-ignition Call Set ringtone repetition Set call times SET RINGTONE REPETITION Floor door call Intercom call External call Left Right 0 0 1 0 0 1 0 0 1 4. Use buttons , to select for which type of call you wish to set the function. 5. Use buttons , to change the number of repetitions as desired for the type of call selected. SET RINGTONE REPETITION Floor door call Intercom call External call Left Right 0 0 3 0 0 1 0 0 1 6. Press to exit and save the changes. • Setting the ringtone repetition • Setting the Alarm function This menu can be used to set the VIP address which will be contacted when a priority call is sent. The procedure applies for all 4 call types; the example below illustrates a Panic priority call. 1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Alarms menu by pressing , and press to access it. SPECIAL SETTINGS MENU Actuator Self-ignition Call Set ringtone repetition Door open Alarms 4. Select the call type and press . Alarms Panic Alarm Fire Priority call 4 5. Select the fi elds which can be changed using , and change the value using , or . CONFIGURE ALARMS 0 0 0 0 0 2 0 0 ViP address: Left Right Active: Audio message 6. Press to exit and save the changes.

• Setting automatic answer

If the Automatic answer function is enabled, the audio will be activated automatically on receipt of a call from the external unit, internal unit or switchboard. 1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings SET AUTOMATIC ANSWER Automatic answer SET AUTOMATIC ANSWER Automatic answer 3. Select the Set automatic answer menu by pressing , and press to access it. 4. Press to enable it. 5. Press to exit and save the changes. • Setting call times 1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Set call times menu by pressing , and press to access it. SPECIAL SETTINGS MENU Alarms Door open Self-ignition Call Set ringtone repetition Set call times SET CALL TIMES Intercom talk time Talk time Reply wait time Reset wait time 4. Select the Reply wait time menu by pressing , and press to access it. 5. Change the value using buttons , . SET REPLY WAIT TIME Reply wait time 0 6 0 6. Press to exit and save the changes. Within this menu, the time can be set for various functions. The Reply wait time setting is shown below, as an example which also applies for the other functions. • Reply wait time: this is the time for which a call from the external or internal unit remains active and waiting for the user to answer. • Talk time: this is the time for which the audio remains active, once a call from the external unit has been accepted. • Intercom talk time: this is the time for which the audio remains active, once a call from an internal unit or from the switchboard has been accepted. • Reset wait time: this is the time for which the audio remains active once a call has ended. The conversation can be resumed if the audio button is pressed again within the set time period.

Planux monitors are equipped with an NC/NO output which can be

programmed as monostable or bistable. This output can be controlled by one of the buttons on board the monitor, or by one of the inputs if suitably confi gured with the Activate output function. • Activate output 1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Activate output menu by pressing , and press to access it. SPECIAL SETTINGS MENU Set automatic answer Set call times Set ringtone repetition Alarms Video mem. records always Activate output 4. Select the fi elds which can be changed using , and change the value using , or . Activate output Seconds Activation period Left Right Normally open Monostable 0 5 , 0 0 Minutes 0 0 Hours Days 0 0 0 0 • The output is set as Normally open by default; tick the box next to Normally open to change this setting to Normally closed. • The output is set as Monostable by default; tick the box next to Monostable to change this setting to Bistable. • Fill in the Activation period fi elds for Monostabile mode. 5. Press to exit and save the changes. • Video memory records always If activated, this function can be used to record images and audio (10 sec.) from the external unit, even if the call is answered. 1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Video memory records always menu by pressing , and press to access it. VIDEO MESSAGE RECORDING Video mem. records always 4. Press to enable it. VIDEO MESSAGE RECORDING Video mem. records always 5. Press to exit and save the changes.

• Call divert

1. Access the installer menu. 2. Select the Special Settings menu by pressing , and press to access it. INSTALLER MENU Special Settings 3. Select the Call divert menu by pressing , and press to access it. SPECIAL SETTINGS MENU Video mem. records always Set automatic answer Set call times Set ringtone repetition Activate output Call divert 4. Select the fi elds which can be changed using , and change the value using , or . Call divert Left Right 0 0 0 0 0 1 0 1 ViP address: Wait time 1 0 Active: • The VIP address fi eld identifi es the internal unit or CPS to which you want to divert the call. • The Wait time fi eld identifi es the wait time before the call is diverted. 5. Press to exit and save the changes. • Reset confi guration This function can be used to restore the factory set values of the monitor, deleting all confi gurations applied in the meantime. 1. Access the installer menu. 2. Select the Confi gure monitor menu using buttons , . 3. Press to access it. 4. Select the Reset confi guration menu using buttons , . 5. Press to access it. INSTALLER MENU Configure monitor CONFIGURE MONITOR Reset configuration About ViP address RESET CONFIGURATION Continue? 6. Press to confi rm. 7. Press to cancel.

Sat 15/06/13 01:21

1. Press PROGRAMMER to access the INSTALLER MENU. 2. Enter the password. 3. Press to confirm the password and access the INSTALLER MENU. The password for the installer menu is 0000. To change the password, please refer to the technical manual for VIP Manager Art. 1449. • Accessing the installer menu • Configuring buttons 1. Access the Installer menu. 2. Access the Configure buttons menu. The buttons on the Sette Stelle internal unit Art. 6501 can be programmed with various functions. The procedure to be used for all buttons is detailed below. INSTALLER MENU Configure buttons Configure monitor Special Settings 3. Select the button you wish to configure. 4. Press next to the function you want to assign to the button. Actuator KEY BUTTON Lock-release • Configuring functions Press the name of the function to access the corresponding configuration menu. ◊ Intercom function This function can be used to send an intercom call to a specific device. Master INTERCOM Configure ViP address Slave 1 1. Access the Configure VIP address menu to set the address of the device you want to associate with the intercom function. 2. Select whether to call the Master or Slave backplate for the set address. If you select Slave, you will also need to set the exact number of the slave as desired. ◊ Self-ignition function This function can be used to view the images transmitted by the camera for one or more devices connected to the system. SELF-IGNITION 00002003 C 1. Press the + icon to add a device to be assigned to the function Automatic camera SELF-IGNITION Configure ViP address Camera number 1 2. Access the Configure VIP address menu to set the address of the device you want to associate with the self-ignition function. 3. Select which device camera you wish to use, from Automatic (in the case of external units or camera number one of modules Art. 1445) or Camera number (if you want to use the camera of a device Art. 1445). 4. To remove a device from the list, press icon C followed by the device. 5. To edit the settings of a device on the list, press the pencil icon followed by the device. 7Stelle monitor Art. 6501

◊ Alarm function

This function can be used to link an alarm call to the button. Panic ALARMS Alarm Fire Priority call 4 1. Press next to the call you want to assign to the button. ◊ Lock-release function This function has two statuses: ◊ Lock-release during call: it will perform one or two actions when a call with the external unit is in progress ◊ Lock-release at rest time: it will perform one or two actions when there are no calls in progress Configuration at rest time CONFIGURE LOCK-RELEASE Configuration during call 1. Select which status you wish to configure. 2. Select which action you wish to configure. Interlocutor CONFIGURE LOCK-RELEASE External unit Relay 1 3. Select which relay you wish to activate. 4. Select whether to interact with the relay of the external unit making the call or a different one. If you select External unit you will need to configure its VIP address. ◊ Actuator function This function is used to activate the relay output of an IO actuator module or that of an expansion device connected to it. Configure ViP address ACTUATOR Module 1 Output 1 1. Access the Configure VIP address menu to set the address of the IO device you want to associate with the actuator function. 2. Select whether to associate one of the expansion modules (1 to 10) or to directly associate one of the two IO module relay outputs (255). 3. Select which output to use (1 to 10 for expansion modules and 1 or 2 for IO module). This function can be used to activate the internal unit NC/NO output by pressing the button. ◊ Activate output function For priority call configuration, see page 62. For output configuration, see page 62.

• Confi guring the monitor

◊ VIP address This menu can be used to confi gure the VIP address of the internal unit. Master CONFIGURE MONITOR Configure ViP address Slave 1 1. Access the Confi gure VIP address menu to set the address of the device. 2. Select whether to set the device as Master or Slave. If you select Slave, you will also need to set the exact number. Master By Master we mean the main internal unit in an apartment. Every Master internal unit in the system must have a different VIP code. The Master internal unit manages all external unit / switchboard / intercom calls. It is essential that, in an apartment, one of the internal units is set as a Master. Slave By Slave we mean one or more secondary internal units (MAX. 15) in an apartment. Each Slave has the same VIP address as the Master internal unit. ◊ About This menu can be used to view system data. CONFIGURE MONITOR About ViP address Reset configuration CONFIGURE MONITOR About ViP address Reset configuration OK MAC: 00:25:34:08:00:DC IP: 169.254.241.41 (A/16) GW: 0.0.0.0 ID: 00000001, SUB: 0 SW: 1.5.3 ◊ Reset confi guration This function can be used to restore the factory set values of the monitor, deleting all confi gurations applied in the meantime. CONFIGURE MONITOR About ViP address Reset configuration CONFIGURE MONITOR About ViP address Reset configuration CONFIRM Continue? CANCEL • Special Settings ◊ Actuator Directory This menu can be used to manage the directory of actuators connected to the system. ACTUATOR DIRECTORY Actuator 1 Abc C 1. Access the Actuator setting menu by pressing the + icon to add a new device to the directory. Configure ViP Address ACTUATOR SETTING Configure Name Module 255 Output 1 2. Access the Confi gure Name menu to associate the actuator with the name which will appear in the directory. 3. Access the Confi gure VIP address menu to enter the address of the actuator module Art. 1443. 4. In the module fi eld, select whether to control the relay on board the module itself (255) or one on board an expansion module connected to it (1 to 10). 5. In the output fi eld, select the exact relay you wish to control. 1 or 2 for relays on board the module art.1443, or 1 to 10 for relays of an expansion module connected to it.

◊ Camera Directory

This menu can be used to manage the directory of cameras connected to the system. CAMERAS DIRECTORY CAMERA 1 Abc C 123 1. Access the Configure camera menu by pressing the + icon to add a new device to the directory. Configure ViP Address CONFIGURE CAMERA Configure Name Automatic camera Camera number 1 2. Access the Configure Name menu to associate the camera with the name which will appear in the directory. 3. Access the Configure VIP address menu to enter the address of the cameras module Art. 1445 or the video external unit. 4. Select whether to use the automatic camera (in the case of an external unit) or indicate the number of the device connected to a cameras module Art. 1445. ◊ Intercom Directory This menu can be used to manage the intercom call directory. INTERCOM CALLS DIRECTORY SMITH Abc C 123 1. Access the Configure intercom menu by pressing the + icon to add a new entry to the directory. Configure ViP Address CONFIGURE INTERCOM Configure Name Master Slave 1 2. Access the Configure Name menu to set the name which will appear in the directory. 3. Access the Configure VIP address menu to enter the address of the device you want to associate with the call. 4. Select whether to call the Master or Slave device. If you select Slave, you will also need to set the exact number of the device to call. ◊ Set ringtone repetition This menu can be used to set the number of times the ringtone is repeated on receipt of a call. SET RINGTONE REPETITION Floor door call 1 Intercom call 1 External call 1 1. Select the number of times the ringtone is repeated for each type of call. ◊ Set call times This menu can be used to change the various call time values. SET CALL TIMES Intercom conversation 90 Conversation 90 Awaiting reply 60 Reset wait times 10 1. Set the duration in seconds for each value. ◊ Awaiting reply: wait time in which, if there is no answer, the call is ended. ◊ Conversation: maximum duration of a conversation with an external unit. ◊ Intercom conversation: maximum duration of a conversation with an internal unit. ◊ Reset wait time: maximum time in which it is possible to pick up the audio line if it is cut off.

◊ Call divert

This menu can be used to set the call divert function. CALL DIVERT Configure ViP Address Activate timed divert Activate divert when busy Wait time 10 1. Access the Configure VIP address menu to enter the address of the device to which the call will be diverted. 2. Set the wait time before the call is diverted. 3. Select whether to divert the call after a set period of time, if the line is busy or in both cases. ◊ Alarms This menu can be used to set the VIP address of the device which will be called when a priority call is made. The configuration for Alarm calls is illustrated below, as an example. The same procedure also applies to the other 3 priority call types. ALARMS Configure ViP Address Audio message 1. Access the Configure VIP address menu to set the address of the device which will be called when an alarm call is made. 2. Select whether to activate the audio message when the call is sent. ◊ Door open This menu can be used to set the address of the external units to be monitored. DOOR OPEN 00002003 C 1. Access the Address menu by pressing the + icon to add the address of the door to be monitored. ◊ Activate output This menu can be used to set the operating mode of the relay on board the monitor. ACTIVATE OUTPUT Monostable Bistable Normally open Normally closed 1. Select whether the output is normally closed or normally open. 2. Select whether the output should be activated in Monostable or Bistable mode. If you select Monostable mode, you will also need to set its switching duration time. ◊ Automatic answer If you activate this option, the monitor will automatically pick up the audio line on receipt of a call. ◊ Video memory records always If you activate this option, the monitor will record the video conversation with the external unit, even if the call is answered.

• Accessing the installer menu

Settings menu Door open Calibration Short cut keys Advanced 1 PASSWORD: 2 3 4 5 6 7 8 9 0 C Enter password **** • Setting the VIP Address Advanced Settings ViP address About Associated camera Associated video output Advanced Settings ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address Confirm Cancel Advanced Settings ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address Confirm Cancel 00000001 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 # ABC DEF MNO JKL GHI WXYZ TUV PQRS • Setting the associated camera Advanced Settings ViP address About Associated camera Associated video output Advanced Settings ViP address About Associated camera Associated video output 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 # ABC DEF MNO JKL GHI WXYZ TUV PQRS ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Active: Confirm Cancel Camera ViP address Automatic camera Camera number Advanced Settings ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Active: Confirm Cancel Camera ViP address Automatic camera Camera number 00002001 • Setting the associated video output Advanced Settings ViP address About Associated camera Associated video output Advanced Settings ViP address About ssociated camera Associated video output 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 # ABC DEF MNO JKL GHI WXYZ TUV PQRS ViP address About ssociated camera Associated video output ViP address About ssociated camera Associated video output Active: Confirm Cancel Video output ViP address Advanced Settings ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Active: Confirm Cancel Video output ViP address 00003001 Porter switchboard Art. 1952 This function can be used to associate a camera with the switchboard, via module Art. 1445. The images from this camera will be displayed on the internal unit monitor during the conversation. This function should be used in conjunction with the previous function (Associated camera). If the VIP address of an IP/PAL module Art. 1446 on the connected monitor is set to the same as the latter, the images from the associated camera will be displayed when the switchboard enters conversation mode.

• Programming the lock-release key

Advanced Settings Associated camera Associated output Self-ignition key Lock-release key Advanced Settings ViP address About Associated camera Associated video output 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 # ABC DEF MNO JKL GHI WXYZ TUV PQRS Advanced Settings ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Active: Confirm Cancel Porter Address Relay number 1 ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Active: Confirm Cancel Porter Address Relay number 1 00002003 Activating / deactivating the OFF key Advanced Settings Associated video output Self-ignition key Lock-release key OFF key disabled • Programming the self-ignition key Advanced Settings About Associated camera Associated output Self-ignition key Advanced Settings ViP address About Associated camera Associated video output 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 # ABC DEF MNO JKL GHI WXYZ TUV PQRS Advanced Settings ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Confirm Cancel Camera ViP address Automatic camera Camera number ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Confirm Cancel Camera ViP address Automatic camera Camera number 00002001 This function can be used to view the images transmitted by the camera for one or more devices connected to the system. • The VIP address function determines the address of the external unit or remote camera module Art. 1445. • Select the Automatic camera function to associate the camera for the external unit. • Select the Camera number function and enter the input number from the 4 available when using a remote camera module Art. 1445. This function can be used to activate a relay for the associated external unit. • In the Porter Address fi eld, enter the VIP address of the external unit you want to associate with the function. • In the Relay number fi eld, enter which of the two external unit relays you want to activate. If activated, the OFF key can be used to switch the switchboard on and off.

Setting the call times

Advanced Settings Lock-release key OFF key disabled Call times Call divert Set call times 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 # ABC DEF MNO JKL GHI WXYZ TUV PQRS Awaiting reply (in) Expressed as min:sec Awaiting ans.serv.act. Conversation Pause Awaiting reply (out) 01:00 00:30 01:30 01:30 00:30 Setting call divert Advanced Settings Lock-release key OFF key disabled Call times Call divert Set call times 2002 Setting activations on call Advanced Settings OFF key disabled Call times Call divert Activations on call Advanced Settings Alarm Panic Fire Call priority 4 Advanced Settings Active: Confirm Address Builtin Module Output Cancel 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 # ABC DEF MNO JKL GHI WXYZ TUV PQRS When this function is active, on receipt of a specifi c type of call the switchboard will activate the output of an actuator module Art. 1443, or of an extension unit connected to it. The following example illustrates the function confi guration procedure for an Alarm call; the same also applies for the other types available in the menu. In the module fi eld, select whether to activate an output on board the actuator Art. 1443 (Builtin), or specify the number of the expansion device with which you want to interact. In the output fi eld, enter the exact number of the output you want to activate (1 or 2 for module art.1443, or 1 to 10 for an expansion device). ◊ Awaiting reply (in): wait time in which a call is ended if it is not answered. ◊ Awaiting ans.serv.act.: maximum time after which the answering service is activated if a call is not answered. ◊ Conversation: maximum conversation duration. ◊ Pause: maximum time a call can be put on hold. ◊ Awaiting reply (out): wait time in which, if there is no answer, the call is ended. This function can be used to divert incoming calls to another switchboard on the list. In the address fi eld, enter the VIP address of actuator Art. 1443.

Chapter 6: Wiring diagrams

Connecting Powercom call button module Art. 3337/3-4-6 VIP/001 J1 3337/4 J1 J2 1395 0 3 2 0 0 1 2 RX- + RX TX + - ~ E T R D O N O N C ~ TX C O M - 4662C L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 + - OUT 1 N C 6203W N - + V V + - AL G N D P F C S S + S 6231 6202W+ 0 V P A N C F P V 0 C N 1 OP + OP- 0 V 1 OUTAL 6304 OUT 1 AL 1 N C P F C IN 1 S N A P + V 0 V 0 AL OUT 1 V 0 - OP + OP 3 N C S + P F C N A P V 0 6501 1 2

Connecting Powercom series digital call module Art. 3370

VIP/002 L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 + - OUT 1 N C 6203W N - + V V + - AL G N D P F C S S + S 6231 6202W+ 0 V P A N C F P V 0 C N 1 OP + OP- 0 V 1 OUTAL 1395 0 3 2 0 0 1 2 3370 D - D - X R X T - R P ~ ~ RX- + RX TX + - ~ E T R D O N O N C ~ TX C O M - 4662C J1 J2 J1 J2 6304 OUT 1 AL 1 N C P F C IN 1 S N A P + V 0 V 0 AL OUT 1 V 0 - OP + OP 3 N C S + P F C N A P V 0 6501 1 2

Connecting backlit module with actuator relay Art. 3327

VIP/003 L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 + - OUT 1 N C 6203W N - + V V + - AL G N D P F C S S AL OUT 1 V 0 - OP + OP 1 N C 0 V P F C N A P V 0 6202W+ 6231 S + + S 6231 6202W+ 0 V P A N C F P V 0 C N 1 OP + OP- 0 V 1 OUTAL S S C F P D N G AL - + 6203W C N 1 4662C+3327 - M O C TX ~ C N O N O D R T E ~ - + TX RX + - RX 2 1 0 0 2 3 0 1395 ~ N O N C ~ C O M SW1 12 12

Connecting IKall call button module Art. 3343/3-4-6

VIP/001I7 J1 J1 J2 L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 + - OUT N - + V V + S 6231 6202W+ 0 V P A N C F P V 0 C N 1 OP + OP- 0 V 1 OUTAL E S NC NO D N G - V V + M O C 4682C R T E RX- + RX TX + - TX - + 1595 120-230 V 33436 AL OUT 1 V 0 - OP + OP 3 N C S + P F C N A P V 0 6501 100-240 V 1 2 6304 OUT 1 AL 1 N C P F C IN 1 S N A P + V 0 V 0

Connecting IKall series audio unit for VIP system Art. 1682

VIP/001IE J1 J1 J2 L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 + - OUT N - + V V E S NC NO D N G - V V + M O C 1682 R T E RX- + RX TX + - TX - + 1595 120-230 V 33436 1 N C 6203W/ + - AL G N D P F C S S 100-240 V 6203B 1 N C 6203W/ + - AL G N D P F C S S 6203B

Connecting IKall series digital call module Art. 3360A

VIP/004I L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 + - OUT N - + V V S V 1 1445 + - CN 1 S V 2 H H S V 3 H S V 4 H D D G N D A U X G N D E S NC NO D N G - V V + M O C 4682C R T E RX- + RX TX + - TX RX + RX - TX + TX - ORANGE WIRE WHITE/ORANGE WIRE WHITE/GREEN WIRE GREEN WIRE - + 1595 120-230 V Vac 24 Vac 24 485 D+ - D 485 P R G D N G S 3360A J2 J1 J2 J1 1952 1 N C 6304 OUT 1 AL 1 N C P F C IN 1 S N A P + V 0 V 0

"V " BLUE

- - S D- 3072B 12 ~ 12 ~ P - R X R - T X 12 ~ 12 ~ - V V + - V V + "V+" BROWN 2E7T000696 + + D D Connecting Vandalcom series digital call modules Art. 3070B and Art. 3072B with IKall series external units Art. 4682C or 1682 VIP/002DVI

" " ORANGE

- ~* ~ - S D- D 3272 12 ~ 12 ~ P - R X R - T X 2M1500299 Connecting Vandalcom series digital call modules Art. 3270 and Art. 3272 with Powercom series external unit Art. 4662C VIP/001IE

4682C + 3268I

1682 + 3262I Connecting Art. 3064/C with audio-video unit 4682C or audio unit Art. 1682 Use the cable included in Art. 3262I, Art. 3268I Remove jumper

Connecting remote camera module Art. 1445

VIP/004 L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 + - OUT N - + V V + S 6231 6202W+ 0 V P A N C F P V 0 C N 1 OP + OP- 0 V 1 OUTAL S V 1 1445 + - CN 1 S V 2 H H S V 3 H S V 4 H D D G N D A U X G N D 1952 1 N C 6304 OUT 1 AL 1 N C P F C IN 1 S N A P + V 0 V 0 E S NC NO D N G - V V + M O C 4682C R T E RX- + RX TX + - TX RX + RX - TX + TX - ORANGE WIRE WHITE/ORANGE WIRE WHITE/GREEN WIRE GREEN WIRE - + 1595 120-230 V Vac 24 Vac 24 485 D+ - D 485 P R G D N G S 3360A J2 J1 J2 J1

Y - V

M O C K P S E S NC NO D N G - V V + M O C 4682C R T E RX- + RX TX + - TX RX + RX - TX + TX - ORANGE WIRE WHITE/ORANGE WIRE WHITE/GREEN WIRE GREEN WIRE - + 1595 120-230 V Vac 24 Vac 24 485 D+ - D 485 P R G D N G S 3360A J2 J1 J2 J1 MONITOR 1952 1 N C 6304 OUT 1 AL 1 N C P F C IN 1 S N A P + V 0 V 0 Connecting PAL / NTSC module Art. 1446 VIP/007I

Connecting repeater module Art. 1447

VIP/005

A D- D+ - +

B A B A B A B A B A 1234 67 5 8 ON SW 4902 SK9071 B A B A B A B A B A D- D+ - + B A B A D- D+ - + B A B A B A B A B A 1234 67 5 8 ON + 12Vcc ~ ~ + - - Connecting IO module Art. 1443 and expansion device Art. SK9071 VIP/010

Request to exit (RTE) button input variant

VIP/RTE Planux VIP output and input variant VIP/FMP

7Stelle output and input variant

VIP/FM7 Smart output and input variant VIP/FMS

Easycom output and input variant

VIP/FME + - Vin Vout + - 2G60000653 CV1 4682C+3268I E S NC NO D N G - V V + M O C R T E RX- + RX TX + - TX - + 1595 120-230 V 1682+3262I 2G60001021 12Vdc 16Vdc MAX N° 4 Connection of Vandalcom nameplate lighting lamp with audio unit Art. 1682 or audio-video unit Art. 4682C (Ikall)

* 20 m MAX

AL OUT 1 V 0 - OP + OP 1 N C 0 V P F C N A P V 0 S + * 1 2 V V + - N OUT - + 1440 IN 1 2 IN 1 2 OUTOUT 3 4 OUT 1441 L O N C N C - + 12/24V AC/DC 1122/A (12V) 470nF AL OUT 1 V 0 - OP + OP 3 N C S + P F C N A P V 0 6501 1229 * * * 20 m MAX AL OUT 1 V 0 - OP + OP 3 N C S + P F C N A P V 0 V V + - N OUT - + 1440 IN 1 2 IN 1 2 OUTOUT 3 4 OUT 1441 L O N C N C - + 12/24V AC/DC 1122/A (12V) 470nF 6304 OUT 1 AL 1 N C P F C IN 1 S N A P + V 0 V 0 OUT 1 AL 1 N C P F C IN 1 S N A P + V 0 V 0 1229 * * 20 m MAX * V V + - N OUT - + 1440 IN 1 2 IN 1 2 OUTOUT 3 4 OUT 1441 L O N C N C - + 12/24V AC/DC 1122/A (12V) 470nF 1 N C 6203W/ + - AL G N D P F C S S 6203B 1229 * * 20 m MAX 1 N C + - AL G N D P F C S S * Connecting Smart additional ringtone variant VIP/FMSS Connecting Easycom additional ringtone variant VIP/FMES Connecting Planux VIP additional ringtone variant VIP/FMPS Connecting 7Stelle additional ringtone variant VIP/FM7S

w w w . c o m e l i t g r o u p . c o m

Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy 2nd edition Rev.4 03/2016 code 2G40001073

Other Intercom System Manuals