Comtech EF Data CRS-170A Installation And Operation Manual
Read Online
Read the Comtech EF Data CRS-170A Installation And Operation Manual online using the built-in PDF viewer.
Text of the manual
IMPORTANT NOTE: The information contained in this document supersedes all previously published
information regarding this product. Product specifications are subject to change without prior notice.
Part Number MN/CRS170A.IOM / CD-CRS170A Revision 14
CRS-170A
L-Band 1:1 Redundancy Switch
Installation and Operation Manual
Accessory Product for use only with Comtech EF Data CDM-625A, CDM-625,
H64/H32/H16/H8 Heights Remote Gateways, CDM-850, CDM-840, CDM-760,
CDM-750, CDM-570AL, CDM-570L, CDM-710GL, CDM-710, CDM-700,
CDM-600L (CLM-9600L), and SDM-300L3 Modems
(Modem Firmware and Hardware Requirements Apply)
Copyright © Comtech EF Data, 2017. All rights reserved. Printed in the USA.
Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161
Part Number MN/CRS170A.IOM / CD-CRS170A
Revision 14
CRS-170A
L-Band 1:1 Redundancy Switch
Installation and Operation Manual
Accessory Product for use only with Comtech EF Data CDM-625A, CDM-625,
H64/H32/H16/H8 Heights Remote Gateways, CDM-850, CDM-840, CDM-760,
CDM-750, CDM-570AL, CDM-570L, CDM-710GL, CDM-710, CDM-700,
CDM-600L (CLM-9600L), and SDM-300L3 Modems
(Modem Firmware and Hardware Requirements Apply)
TABLE OF CONTENTS
TABLE OF CONTENTS ........................................................................................................... III
TABLES ................................................................................................................................. VIII
FIGURES ................................................................................................................................ VIII
PREFACE ............................................................................................................................... XIII
About this Manual ................................................................................................................................... xiii
Related Documents ................................................................................................................................ xiii
Conventions and References ................................................................................................................... xiv
Patents and Trademarks ......................................................................................................................... xiv
Warnings, Cautions and Notes .............................................................................................................. xiv
Examples of Multi-Hazard Notices ....................................................................................................... xiv
Recommended Standard Designations .................................................................................................. xiv
Safety and Compliance ............................................................................................................................. xv
Electrical Safety and Compliance ........................................................................................................... xv
Electrical Installation .............................................................................................................................. xv
Operating Environment .......................................................................................................................... xv
Equipment Connection ........................................................................................................................... xv
European Union Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive
(1999/5/EC) and EN 301 489-1 ............................................................................................................. xvi
European Union Electromagnetic Compatibility (EMC) Directive (2004/108/EC) ......................... xvi
European Union Low Voltage Directive (LVD) (2006/95/EC) ....................................................... xvii
European Union RoHS Directive (2002/95/EC) .............................................................................. xvii
European Union Telecommunications Terminal Equipment Directive (91/263/EEC) .................... xvii
CE Mark ........................................................................................................................................... xvii
Product Support ...................................................................................................................................... xvii
Comtech EF Data Headquarters .......................................................................................................... xviii
Warranty Policy ..................................................................................................................................... xviii
Limitations of Warranty ...................................................................................................................... xviii
Exclusive Remedies ............................................................................................................................... xix
CHAPTER 1.
INTRODUCTION ........................................................................................ 1–1
1.1
Overview ..................................................................................................................................... 1–1
1.2
Physical Features ....................................................................................................................... 1–3
1.2.1
Modem Side Features .............................................................................................................. 1–3
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
iv
1.2.2
Top and Antenna Side Features ............................................................................................... 1–4
1.3
Functional Description .............................................................................................................. 1–5
1.3.1
Switch / Modem Operation...................................................................................................... 1–5
1.3.2
1:1 IP Redundancy Data Switching ......................................................................................... 1–7
1.3.2.1
Managed Switch Mode for CDM-625A or CDM-625, Heights Remote Gateway,
Advanced VSAT CDM-850 or CDM-840, CDM-760, CDM-750, CDM-710GL, CDM-710, or
CDM-700 ........................................................................................................................................ 1–7
1.3.2.2
Router Mode For CDM-625A or CDM-625 WITH Optional IP Packet Processor ...... 1–10
1.3.2.3
Managed Switch or Router Modes for CDM-570L/AL WITH Optional IP Module or
Packet Processor ............................................................................................................................. 1–12
1.3.3
CRS-170A Operation with CDM-600L (CLM-9600L) and SDM-300L3 Modems ............. 1–15
1.3.3.1
Operation with CDM-600L (CLM-9600L) Modems and CRS-150 Switch ................. 1–15
1.3.3.2
Operation with SDM-300L3 Modems and SMS-301 Switch ....................................... 1–17
1.4
Summary of Specifications ...................................................................................................... 1–18
CHAPTER 2.
INSTALLATION .......................................................................................... 2–1
2.1
Unpack and Inspect the Shipment ............................................................................................ 2–1
2.2
Mount the Unit ........................................................................................................................... 2–2
CHAPTER 3.
SWITCH CONNECTORS AND PINOUTS .................................................. 3–1
3.1
Cabling Connection Types ........................................................................................................ 3–1
3.1.1
Coaxial Cable Connections ..................................................................................................... 3–1
3.1.1.1
Type ‘BNC’ .................................................................................................................... 3–2
3.1.1.2
Type ‘TNC’..................................................................................................................... 3–2
3.1.1.3
Type ‘N’ .......................................................................................................................... 3–2
3.1.1.4
Type ‘F’ .......................................................................................................................... 3–2
3.1.1.5
Type ‘SMA’ (Subminiature Version ‘A’) ....................................................................... 3–2
3.1.2
D-Subminiature Cable Connections ........................................................................................ 3–3
3.1.3
RJ-45, RJ-48 Cable Connections ............................................................................................. 3–3
3.2
CRS-170A User Connectors ...................................................................................................... 3–4
3.2.1
Modem Side Connectors ......................................................................................................... 3–4
3.2.1.1
IF Connectors (50Ω Type ‘N’) ....................................................................................... 3–4
3.2.1.2
J3 | Control Connector (Top) – Modem ‘A’ (DB-9F)..................................................... 3–5
3.2.1.3
J4 | Control Connector (Bottom) – Modem ‘B’ (DB-9F) ............................................... 3–5
3.2.2
Antenna Side Connectors ........................................................................................................ 3–6
3.2.2.1
RF Connectors (50Ω Type ‘N’) ...................................................................................... 3–6
3.2.2.2
Ground Stud .................................................................................................................... 3–6
CHAPTER 4.
MODEM AND SWITCH CONFIGURATION ................................................ 4–1
4.1
Overview ..................................................................................................................................... 4–1
4.2
Configure the CDM-625A or CDM-625 for 1:1 Redundancy ................................................ 4–3
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
v
4.2.1
CDM-625A or CDM-625 Remote User M&C Ethernet Interface .......................................... 4–3
4.2.1.1
For CDM-625A or CDM-625s without the Optional IP Packet Processor ..................... 4–3
4.2.1.2
For CDM-625A or CDM-625s Equipped With the Optional IP Packet Processor ......... 4–4
4.2.2
Configure CDM-625A or CDM-625 Carrier-in-Carrier® for Redundancy Operation ........... 4–4
4.3
Heights Remote Gateways in 1:1 Redundancy ........................................................................ 4–5
4.4
Advanced VSAT CDM-850 or CDM-840 Operation in 1:1 Redundancy ............................. 4–7
4.5
CDM-760 or CDM-750 Operation in 1:1 Redundancy .......................................................... 4–9
4.6
Configure the CDM-570Ls or CDM-570ALs for 1:1 Redundancy ..................................... 4–11
4.6.1
CDM-570L or CDM-570AL Non-IP Redundancy Configuration ........................................ 4–12
4.6.2
IP Redundancy Configuration ............................................................................................... 4–13
4.7
Configure the CDM-710GLs, CDM-710s, or CDM-700s for 1:1 Redundancy .................. 4–15
4.7.1
Non-IP Redundancy Configuration ....................................................................................... 4–16
4.7.2
IP Redundancy Configuration ............................................................................................... 4–16
4.8
CDM-600L (CLM-9600L) Operation in 1:1 Redundancy ................................................... 4–17
4.9
SDM-300L3 Operation in 1:1 Redundancy ........................................................................... 4–17
4.10
CRS-170A DIP Switch Settings .............................................................................................. 4–19
CHAPTER 5.
CABLES AND CONNECTIONS ................................................................. 5–1
5.1
Overview ..................................................................................................................................... 5–1
5.2
Common CRS-170A 1:1 Redundancy Control / IF Interface Cabling Kits ......................... 5–3
5.3
Cabling to the CDM-625A or CDM-625 .................................................................................. 5–5
5.3.1
CRS-170ACDM-625A or CDM-625 Control and IF Interface Connections Using Cabling
Kit KT-0000160 ................................................................................................................................... 5–5
5.3.1.1
Modem-to-Switch Control Interface Connection ........................................................... 5–6
5.3.1.2
Modem-to-Switch IF Interface Connection .................................................................... 5–7
5.3.1.2.1
Modem-to-Switch L-Band (Rx/Tx) IF Interface Connection ................................... 5–7
5.3.1.2.2
Modem-to-Switch L-Band Tx / 70/140 MHz Rx IF Interface Connection .............. 5–8
5.3.2
Modem-to-User Data Interface Connections and Examples ................................................... 5–9
5.3.2.1
Modem-to-User Non-IP Data Interface Connections and Examples .............................. 5–9
5.3.2.1.1
EIA-422/232 Interface Example ............................................................................. 5–10
5.3.2.1.2
HSSI Interface Example ......................................................................................... 5–10
5.3.2.1.3
Quad E1 Interface Example .................................................................................... 5–11
5.3.2.1.4
G.703 Balanced Interface Example ........................................................................ 5–12
5.3.2.1.5
G.703 Unbalanced Interface Example .................................................................... 5–12
5.3.2.1.6
ASI Interface Example ........................................................................................... 5–13
5.3.2.1.7
Overhead Interface Example .................................................................................. 5–13
5.3.2.1.8
Engineering Service Channel (ESC) Interface Example ........................................ 5–14
5.3.2.2
Modem-to-User IP (10/100 Ethernet) Interface Examples ........................................... 5–15
5.3.2.2.1
Data Interface Connections Using IP Sub-Mux ..................................................... 5–15
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
vi
5.3.2.2.2
Managed Switch Mode (with/without the Optional IP Packet Processor) ............. 5–15
5.3.2.2.3
Router Mode (Requires Optional IP Packet Processor) .......................................... 5–18
5.3.2.3
PMSI Interface Example ............................................................................................... 5–20
5.4
Cabling to the Heights Remote Gateway (HRG) .................................................................. 5–21
5.4.1
CRS-170A HRG Control and IF Interface Connections Using Cabling Kit KT-0000160 .......
............................................................................................................................................... 5–21
5.4.1.1
Unit-to-Switch Control Interface Connection ............................................................... 5–22
5.4.1.2
Unit-to-Switch IF Interface Connection ....................................................................... 5–23
5.4.2
Unit-to-User Data Interface Connections and Examples ....................................................... 5–24
5.4.2.1
HRG Managed Switch Mode (Ethernet Bridge Mode) ................................................ 5–24
5.4.2.2
HRG Router Mode ........................................................................................................ 5–26
5.5
Cabling to the Advanced VSAT CDM-850 ............................................................................ 5–27
5.5.1
CRS-170A CDM-850 Control and IF Interface Connections Using Cabling Kit
KT-0000160 ....................................................................................................................................... 5–27
5.5.1.1
Unit-to-Switch Control Interface Connection ............................................................... 5–28
5.5.1.2
Unit-to-Switch IF Interface Connection ....................................................................... 5–29
5.5.2
Unit-to-User Data Interface Connections and Examples ....................................................... 5–30
5.5.2.1
CDM-850 Managed Switch Mode (Ethernet Bridge Mode)......................................... 5–30
5.5.2.2
CDM-850 Router Mode ................................................................................................ 5–32
5.6
Cabling to the Advanced VSAT CDM-840 ............................................................................ 5–33
5.6.1
CRS-170A CDM-840 Control and IF Interface Connections Using Cabling Kit
KT-0000160 ....................................................................................................................................... 5–33
5.6.1.1
Unit-to-Switch Control Interface Connection ............................................................... 5–34
5.6.1.2
Unit-to-Switch IF Interface Connection ....................................................................... 5–35
5.6.2.1
RJ-45 Gigabit Ethernet Data Interface Example........................................................... 5–36
5.7
CDM-840 Block Diagram – G.703 Unbalanced E1 Data Interface Cabling to the CDM-760
or CDM-750 ........................................................................................................................................... 5–38
5.7.1
CRS-170A CDM-760 or CDM-750 Control and IF Interface Connections Using Cabling
Kit KT-0000160 ................................................................................................................................. 5–38
5.7.1.1
Modem-to-Switch Control Interface Connection ......................................................... 5–39
5.7.1.2
Modem-to-Switch IF Interface Connection .................................................................. 5–40
5.7.2
Modem-to-User Data Interface Connections and Examples ................................................. 5–41
5.8
Cabling to the CDM-570AL or CDM-570L ........................................................................... 5–45
5.8.1
CRS-170ACDM-570AL or CDM-570L Interface Connections Using 1:1 Redundancy Kit
KT/10860-1 ........................................................................................................................................ 5–45
5.8.1.1
Modem-to-Switch Control Interface Connection ......................................................... 5–46
5.8.1.2
Modem-to-Switch IF Interface Connection .................................................................. 5–47
5.8.1.3
Modem-to-User Data Interface Connections and Examples ......................................... 5–48
5.8.1.3.1
Modem-to-User Non-IP Data Interface Connections and Examples ...................... 5–48
5.8.1.3.1.1
EIA-422/232 Interface Example ..................................................................... 5–49
5.8.1.3.1.2
G.703 Balanced Interface Example ................................................................. 5–49
5.8.1.3.1.3
G.703 Unbalanced Interface Example ............................................................ 5–50
5.8.1.3.1.4
Modem-to-User IP (10/100 Ethernet) Interface Example ............................... 5–51
5.9
Cabling to the CDM-710GL .................................................................................................... 5–53
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
vii
5.9.1
CRS-170A CDM-710GL Control and IF Interface Connections Using Cabling Kit
KT/12551 ............................................................................................................................................ 5–53
5.9.1.1
Modem-to-Switch Control Interface Connection ......................................................... 5–54
5.9.1.2
Modem-to-Switch IF Interface Connection .................................................................. 5–55
5.9.2
Modem-to-User Data Interface Kit and Connection Examples ............................................. 5–56
5.9.2.1
Modem-to-User Non-IP Data Interface Kit and Connection Examples ....................... 5–56
5.9.2.1.1
Single G.703 E3/T3/STS-1 75Ω Data Interface (CDI-10-1) Kit KT/12583........... 5–57
5.9.2.1.2
HSSI Data Interface (CDI-60) Kit KT/12586 ......................................................... 5–58
5.9.2.2
Gigabit Ethernet Interface (CDI-70) Example .............................................................. 5–59
5.10
Cabling to the CDM-710 ......................................................................................................... 5–61
5.10.1
CRS-170A CDM-710 Control and IF Interface Connections Using Cabling Kit
KT/12551 ........................................................................................................................................... 5–61
5.10.1.1
Modem-to-Switch Control Interface Connection ..................................................... 5–62
5.10.1.2
Modem-to-Switch IF Interface Connection .............................................................. 5–63
5.10.2
Modem-to-User Data Interface Kit and Connection Examples ........................................ 5–64
5.10.2.1
Modem-to-User Non-IP Data Interface Kit and Connection Examples ................... 5–64
5.10.2.1.1
ASI 75Ω Data Interface (CDI-40) Kit KT/12579 ................................................. 5–65
5.10.2.1.2
HSSI Data Interface (CDI-60) Interface Kit KT/12578 ....................................... 5–66
5.10.2.2
Gigabit Ethernet Data Interface (CDI-70) Example ................................................. 5–67
5.11
Cabling to the CDM-700 ......................................................................................................... 5–69
5.11.1
CRS-170A CDM-700 Connections Using Control and IF Interface Cabling Kit
KT/12551 ........................................................................................................................................... 5–69
5.11.1.1
Modem-to-Switch Control Interface Connection ..................................................... 5–70
5.11.1.2
Modem-to-Switch IF Interface Connection .............................................................. 5–71
5.11.2
Modem-to-User Data Interface Kit and Connection Examples ........................................ 5–72
5.11.2.1
Modem-to-User Non-IP Data Interface Kit and Connection Examples ................... 5–72
5.11.2.1.1
Dual G.703 E3/T3/STS-1 75Ω Data Interface (CDI-10) Kit KT/12582 and HSSI
Data Interface (CDI-60) Kit KT/12586 ..................................................................................... 5–73
5.11.2.1.2
155MB Copper Data Interface (CDI-50) Kit KT/12583 ...................................... 5–74
5.11.2.1.3
OC-3 Data Interface (CDI-50) Kits KT/12585 (Single-Mode) or KT/12584 (Multi-
Mode)
.............................................................................................................................. 5–75
5.11.2.2
Gigabit Ethernet Data Interface (CDI-70) Example ................................................. 5–76
5.12
Cabling the CDM-600L (CLM-9600L) .................................................................................. 5–77
5.13
Cabling the SDM-300L3 .......................................................................................................... 5–79
APPENDIX A.
CABLE DRAWINGS ................................................................................... A-1
A.1
Overview ..................................................................................................................................... A-1
A.2
Control Interface Cables ........................................................................................................... A-2
A.2.1
Switch-to-Modem, Universal Control Cable (DB-9MDB-9M) ...................................... A-3
A.2.2
Switch-to-Modem, Adapter Control Cable, RoHS (DB-9MDB-15F) ............................ A-4
A.2.3
Switch-to-Modem, Optional ‘Y’ Splitter Adapter Control Cable ((2X) DB-9MDB-15F) A-
5
A.2.4
Switch-to-Modem, Optional Control Cable, Non-muting (DB-9MDB-15F) .................. A-6
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
viii
A.2.5
Modem-to-Switch (CRS-170A and CRS-150), Data / Control ‘Y’ Cable
(DB-25MDB-25M, DB-9M) ............................................................................................................ A-7
A.2.6
Modem-to-Switch (CRS-170A and SMS-301), Control Cable (DB-9MDB-15M) ........ A-8
A.3
IF / Data Interface Cables ......................................................................................................... A-9
A.3.1
Switch-to-Modem / Modem-to-User, L-Band Coaxial Cable, RoHS, Type ‘N’ 50Ω ...... A-11
A.3.2
Switch-to-Modem / Modem-to-User, 70/140 MHz Coaxial Cable, RoHS, Type ‘BNC’ 75Ω .
........................................................................................................................................... A-12
A.3.3
Modem-to-User, Splitter Cable (DB-25F(2X) DB-25M) ............................................. A-13
A.3.4
Modem-to-User, CDM-625A, CDM-625 Data ‘Y’ Splitter Cable (DB-9F(2X) DB-9M) ....
........................................................................................................................................... A-14
A.3.5
Modem-to-User, Quad E1 ‘Y’ Splitter Adapter Cable (DB-9M(2X) DB-15F) ............ A-15
A.3.6
Modem-to-User, Quad E1 ‘Y’ Splitter Adapter Cable (DB-9M (2X) RJ-48F) ............ A-16
A.3.7
Modem-to-User, Quad E1 ‘Y’ Splitter Adapter Cable Kit (KT-0000122) ....................... A-17
A.3.8
Modem-to-User, Overhead User Data ‘Y’ Splitter Cable (HD-44F(2X) HD-44M) ..... A-18
A.3.9
Modem-to-Modem CDM-625A, CDM-625 CnC® Plus Shielded Multi-drop Cable
(DB-9MDB-9M) ............................................................................................................................. A-19
A.3.10
Modem-to-User, RoHS Optical Gigabit Ethernet Cable Assemblies, Single-Mode OR Multi-
Mode ((2X) Type ‘LC’(4X) Type ‘LC’) ........................................................................................ A-20
A.3.11
Modem-to-User, G.703 Balanced User Data ‘Y’ Splitter Cable (DB-15M(2X) DB-15M) ..
........................................................................................................................................... A-21
A.3.12
Modem-to-User, HSSI User Data ‘Y’ Splitter Cable (HD-50M(2X) HD-50F) ............ A-22
A.3.13
Modem-to-User, RoHS OC-3 Cable Assemblies, Single-Mode OR Multi-Mode (Type
‘SC/UPC’(2X) Type ‘SC/UPC’) ................................................................................................... A-23
TABLES
Table 1-1. CRS-170A Compatibility Summary ........................................................................................ 1–2
Table 3-1. Modem Side Type ‘Type ‘N’ Connectors ............................................................................... 3–4
Table 3-2. J3 | Control A Modem Connector Pinouts ............................................................................... 3–5
Table 3-3. J4 | Control B Modem Connector Pinouts ............................................................................... 3–5
Table 3-4. J7 | Rx and J8 | Tx ‘Type ‘N’ Connectors ............................................................................... 3–6
Table 4-1. CRS-170A “Mode” DIP Switches – Product Compatibility Settings ................................... 4–20
Table 4-2. CRS-170A “Switch Control” DIP Switches – Functional Settings ....................................... 4–20
FIGURES
Figure 1-1. CRS-170A L-Band 1:1 Redundancy Switch Module ............................................................ 1–1
Figure 1-2. CRS-170A – Modem Side Connectors .................................................................................. 1–3
Figure 1-3. CRS-170A – Top and Antenna Side Features ........................................................................ 1–4
Figure 1-4. 1:1 IP Redundancy Managed Switch Mode for CDM-625A or CDM-625, Heights Remote
Gateway, Advanced VSAT CDM-850 or CDM-840, CDM-760, CDM-750, CDM-710GL, CDM-
710, or CDM-700 ............................................................................................................................. 1–8
Figure 1-5. 1:1 IP Redundancy Managed Switch Mode – Switchover for CDM-625A or CDM-625,
Heights Remote Gateway, Advanced VSAT CDM-850 or CDM-840, CDM-760, CDM-750,
CDM-710GL, CDM-710, or CDM-700 ........................................................................................... 1–9
Figure 1-6. CDM-625A or CDM-625 1:1 IP Redundancy Router Mode – ‘A’ Online .......................... 1–10
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
ix
Figure 1-7. CDM-625A or CDM-625 1:1 IP Redundancy Router Mode Switchover (‘B’ Online) ....... 1–11
Figure 1-8. CDM-570L/AL 1:1 IP Redundancy Router Mode – ‘A’ Online ......................................... 1–13
Figure 1-9. CDM-570L/AL 1:1 IP Redundancy Router Mode Switchover – ‘B’ Online....................... 1–14
Figure 1-10. CRS-150 1:1 Redundancy Switch ...................................................................................... 1–15
Figure 1-11. Comtech EF Data SMS-301 1:1 Redundancy Switch ........................................................ 1–17
Figure 2-1. Optional KT/11708 Switch Mounting Kit.............................................................................. 2–2
Figure 3-1. Coaxial Connector Examples ................................................................................................. 3–1
Figure 3-2. D-Subminiature Connector Examples .................................................................................... 3–3
Figure 3-3. CRS-170A – Modem Side Connectors .................................................................................. 3–4
Figure 3-4. CRS-170A – Antenna Side Connectors and Ground Stud (Rev. A and Later Versions) ....... 3–6
Figure 4-1. Heights Remote Gateway HTTP Interface ‘Utility’ Page Example (Page Banner, VFP NOT
SHOWN) .......................................................................................................................................... 4–5
Figure 4–2. Heights Remote Gateway ‘Utility | Utility’ Page “Redundancy” Section:
Online/Offline Examples ............................................................................................................... 4–6
Figure 4-3. Advanced VSAT CDM-850 or CDM-840 HTTP Interface ‘Utility | Utility’ Page Example
(Page Banner, VFP NOT SHOWN) ................................................................................................. 4–7
Figure 4-4. CDM-570L or CDM-570AL Configuration Interface Examples ......................................... 4–11
Figure 4-5. CDM-570L or CDM-570AL CLI 1:1 Redundancy Configuration Screen .......................... 4–14
Figure 4-6. CRS-170A Antenna Side Controls ....................................................................................... 4–19
Figure 5-1. CDM-625A or CDM-625 Modem-to-Switch Control Connections ...................................... 5–6
Figure 5-2. CDM-625A or CDM-625 Modem-to-Switch L-Band IF Connections .................................. 5–7
Figure 5-3. CDM-625A or CDM-625 Modem-to-Switch L-Band Tx / 70/140 MHz Rx IF Connections .....
.......................................................................................................................................................... 5–8
Figure 5-4. CDM-625A or CDM-625 Block Diagram – UserModemSwitchTraffic .................... 5–9
Figure 5-5. CDM-625A or CDM-625 EIA-422/232 1:1 Example ......................................................... 5–10
Figure 5-6. CDM-625A or CDM-625 HSSI 1:1 Example ...................................................................... 5–10
Figure 5-7. CDM-625A or CDM-625 Quad E1 1:1 Example ................................................................ 5–11
Figure 5-8. CDM-625A or CDM-625 G.703 Balanced 1:1 Example ..................................................... 5–12
Figure 5-9. CDM-625A or CDM-625 G.703 Unbalanced 1:1 Example ................................................. 5–12
Figure 5-10. CDM-625A or CDM-625 ASI 1:1 Example ...................................................................... 5–13
Figure 5-11. CDM-625A or CDM-625 Overhead 1:1 Example ............................................................. 5–13
Figure 5-12. CDM-625A or CDM-625 ESC 1:1 Example ..................................................................... 5–14
Figure 5-13. CDM-625A or CDM-625 Block Diagram – 10/100 Ethernet 1:1 Managed Switch Mode .......
........................................................................................................................................................ 5–16
Figure 5-14. CDM-625A or CDM-625 10/100 Ethernet 1:1 Cabling Example – Managed Switch Mode
(with/without Dedicated Management Port) .................................................................................. 5–17
Figure 5-15. CDM-625A or CDM-625 10/100 Ethernet 1:1 Example – Router Mode Block Diagram ........
........................................................................................................................................................ 5–18
Figure 5-16. CDM-625A or CDM-625 10/100 Ethernet 1:1 Cabling Example – Router Mode ............ 5–19
Figure 5-17. CDM-625A or CDM-625 PMSI 1:1 Example ................................................................... 5–20
Figure 5-18. HRG Unit-to-Switch Control Connections ........................................................................ 5–22
Figure 5-19. HRG Unit-to-Switch L-Band IF Connections (H64 Shown) ............................................. 5–23
Figure 5-20. HRG Block Diagram – Gigabit Ethernet 1:1 Managed Switch Mode ............................... 5–24
Figure 5-21. HRG Gigabit Ethernet 1:1 Cabling Example (H64 Shown) – Managed Switch Mode ..... 5–25
Figure 5-22. HRG Gigabit Ethernet 1:1 Cabling Example – Router Mode ............................................ 5–26
Figure 5-23. CDM-850 Unit-to-Switch Control Connections ................................................................ 5–28
Figure 5-24. CDM-850 Unit-to-Switch L-Band IF Connections ............................................................ 5–29
Figure 5-25. CDM-850 Block Diagram –Gigabit Ethernet 1:1 Managed Switch Mode ........................ 5–30
Figure 5-26. CDM-850 Gigabit Ethernet 1:1 Cabling Example – Managed Switch Mode .................... 5–31
Figure 5-27. CDM-850 Gigabit Ethernet 1:1 Cabling Example – Router Mode .................................... 5–32
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
x
Figure 5-28. CDM-840 Unit-to-Switch Control Connections ................................................................ 5–34
Figure 5-29. CDM-840 Unit-to-Switch L-Band IF Connections ............................................................ 5–35
Figure 5-30. CDM-840 Block Diagram – Gigabit Ethernet 1:1 Operation ............................................ 5–36
Figure 5-31. CDM-840 Unbalanced G.703 E3/T375Ω Interface Kit – KT/12542 ................................. 5–37
Figure 5-32. CDM-760 or CDM-750 Modem-to-Switch Control Connections ..................................... 5–39
Figure 5-33. CDM-760 or CDM-750 Modem-to-Switch L-Band IF Connections ................................. 5–40
Figure 5-34. CDM-760 or CDM-750 RJ-45 Gigabit Ethernet 1:1 Example .......................................... 5–41
Figure 5-35. CDM-760 or CDM-750 Optical Gigabit Ethernet 1:1 Example ........................................ 5–42
Figure 5-36. CDM-760 or CDM-750 Block Diagram – UserModemSwitchTraffic .................. 5–43
Figure 5-37. CDM-760 or CDM-750 G.703 E3/T3 PIIC Interface Kit KT/12542 ................................. 5–44
Figure 5-38. CDM-570AL or CDM-570L Modem-to-Switch Control Connections .............................. 5–46
Figure 5-39. CDM-570AL or CDM-570L Modem-to-Switch L-Band Connections .............................. 5–47
Figure 5-40. CDM-570L or CDM-570AL or CDM-570L Block Diagram –
UserModemSwitchTraffic .................................................................................................. 5–48
Figure 5-41. CDM-570L or CDM-570AL or CDM-570L EIA-422/232 1:1 Example .......................... 5–49
Figure 5-42. CDM-570AL or CDM-570L G.703 Balanced 1:1 Example .............................................. 5–49
Figure 5-43. CDM-570AL or CDM-570L G.703 Unbalanced 1:1 Example .......................................... 5–50
Figure 5-44. CDM-570AL or CDM-570L IP (10/100 Ethernet) 1:1 Example ....................................... 5–51
Figure 5-45. CDM-710GL Modem-to-Switch Control Connections ...................................................... 5–54
Figure 5-46. CDM-710GL Modem-to-Switch L-Band IF Connections ................................................. 5–55
Figure 5-47. CDM-710GL Block Diagram – UserModemSwitchTraffic ................................... 5–56
Figure 5-48. CDM-710GL CDI-10-1 Single G.703 E3/T3/STS-1 1:1 Example .................................... 5–57
Figure 5-49. CDM-710GL CDI-60 HSSI 1:1 Example .......................................................................... 5–58
Figure 5-50. CDM-710GL CDI-70 Gigabit Ethernet 1:1 Example ........................................................ 5–59
Figure 5-51. CDM-710 Modem-to-Switch Control Connections ........................................................... 5–62
Figure 5-52. CDM-710 Modem-to-Switch L-Band IF Connections....................................................... 5–63
Figure 5-53. CDM-710 Block Diagram – UserModemSwitchTraffic ........................................ 5–64
Figure 5-54. CDM-710 CDI-40 ASI 1:1 Example.................................................................................. 5–65
Figure 5-55. CDM-710 CDI-60 HSSI 1:1 Example ............................................................................... 5–66
Figure 5-56. CDM-710 CDI-70 Gigabit Ethernet 1:1 Example ............................................................. 5–67
Figure 5-57. CDM-700 Modem-to-Switch Control Connections ........................................................... 5–70
Figure 5-58. CDM-700 Modem-to-Switch L-Band IF Connections....................................................... 5–71
Figure 5-59. CDM-700 Block Diagram – UserModemSwitchTraffic ........................................ 5–72
Figure 5-60. CDM-700 CDI-10 G.703 E3/T3/STS-1, CDI-60 HSSI 1:1 Example ................................ 5–73
Figure 5-61. CDM-700 CDI-50 155MB Copper 1:1 Example ............................................................... 5–74
Figure 5-62. CDM-700 CDI-50 OC-3 1:1 Example (Single-Mode shown) ........................................... 5–75
Figure 5-63. CDM-700 CDI-70 Gigabit Ethernet 1:1 Example ............................................................. 5–76
Figure 5-64. CDM-600L (CLM-9600L) Block Diagram – Cable Connections ..................................... 5–77
Figure 5-65. SDM-300L3 Block Diagram – Cable Connections ............................................................ 5–79
Figure A-1. Universal Control Cable (CA/WR9378-4) ........................................................................... A-3
Figure A-2. Adapter Control Cable (CA/WR12135-1) ............................................................................. A-4
Figure A-3. Optional ‘Y’ Splitter Adapter Control Cable (CA/WR13011-4) .......................................... A-5
Figure A-4. Optional Control Cable (CA-0000187) ................................................................................. A-6
Figure A-5. Data / Control ‘Y’ Cable (CA/WR10456-4) ......................................................................... A-7
Figure A-6. Control Cable (CA/WR10163-1) .......................................................................................... A-8
Figure A-7. Tx/Rx 50Ω Type ‘N’ Coaxial Cable (CA/RF10453-4) ....................................................... A-11
Figure A-8. Tx/Rx/User Data 75Ω Type ‘BNC’ Coaxial Cable (CA/BNC75OHM) ............................. A-12
Figure A-9. 1:1 User Data Splitter Cable (CA/RB10461-1) ................................................................... A-13
Figure A-10. 1:1 User Data ‘Y’ Splitter Cable (CA-0000071) ............................................................... A-14
Figure A-11. Quad E1 User Data ‘Y’ Splitter Adapter Cable (CA-0000163) ........................................ A-15
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
xi
Figure A-12. Quad E1 User Data ‘Y’ Splitter Adapter Cable (CA-0000164) ........................................ A-16
Figure A-13. Quad E1 User Data ‘Y’ Splitter Adapter Cable Kit (KT-0000122) .................................. A-17
Figure A-14. Overhead User Data ‘Y’ Splitter Cable (CA-0000070) .................................................... A-18
Figure A-15. CDM-625A, CDM-625 CnC® Plus Shielded Multi-drop Cable (CA-0000276) .............. A-19
Figure A-16. Optical Gigabit Ethernet User Data Cable Assembly ....................................................... A-20
Figure A-17. G.703 Balanced User Data ‘Y’ Splitter Cable (CA/WR10522-1)..................................... A-21
Figure A-18. HSSI User Data ‘Y’ Splitter Cable (PP/SC3523) .............................................................. A-22
Figure A-19. OC-3 User Data Cable Assembly ...................................................................................... A-23
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM / CD-CRS170A
Table of Contents
Revision 14
xii
BLANK PAGE
About this Manual
This manual provides installation and operation information for the Comtech EF Data CRS-170A L-Band 1:1
Redundancy Switch. This document is intended for anyone who installs or operates the CRS-170A in a 1:1
redundant system.
Related Documents
•
CDM-625A Advanced Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM625A)
•
CDM-625 Advanced Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM625)
•
Heights Networking Platform Spoke (Remote) Site Products Installation and Operation Manual
(including H64, H32, H16, or H8 Heights Remote Gateway)
(CEFD P/N MN-HEIGHTS-SPOKE)
•
CDM-850 Remote Router Installation and Operation Manual
(CEFD P/N MN-CDM850)
•
CDM-840 Remote Router Installation and Operation Manual
(CEFD P/N MN-CDM840)
•
CDM-760 Advanced High-Speed Trunking Modem Installation and Operation Manual
(CEFD P/N MN-CDM760)
•
CDM-750 Advanced High-Speed Trunking Modem Installation and Operation Manual
(CEFD P/N MN-CDM750)
•
CDM-570A/CDM-570AL/CDMR-570AL Satellite Modem Installation and Operation Manual (CEFD
P/N MN-CDM570A)
•
CDM-570/CDM-570L/CDMR-570L Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM570L.IOM)
•
CDM-710G/710GL High-Speed Satellite Modem Installation and Operation Manual (CEFD P/N MN-
CDM710G)
•
CDM-710 Broadcast Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM710.IOM)
•
CDM-700 High-Speed Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM700.IOM)
•
CDM-600L Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM600L.IOM)
•
CLM-9600L Open Network Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CLM9600L.IOM)
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Preface
Revision 14
xiv
•
SDM-300L3 Satellite Modem Installation and Operation Manual
(CEFD P/N MN/SDM300L3.IOM)
•
CRS-150 1:1 Redundancy Switch Installation and Operation Manual
(CEFD P/N MN/CRS150.IOM)
•
SMS-301 Redundancy Switch Installation and Operation Manual
(CEFD P/N MN/SMS301.IOM)
Conventions and References
Patents and Trademarks
See all of Comtech EF Data's Patents and Patents Pending at http://patents.comtechefdata.com.
Comtech EF Data acknowledges that all trademarks are the property of the trademark owners.
Warnings, Cautions and Notes
A WARNING INFORMS YOU ABOUT A POSSIBLE HAZARD THAT MAY CAUSE DEATH
OR SERIOUS INJURY.
A CAUTION informs you about a possible hazard that MAY CAUSE INJURY or
PROPERTY DAMAGE.
A NOTE gives you important information about a task or the equipment.
A REFERENCE directs you to additional information about a task or the equipment.
Examples of Multi-Hazard Notices
Recommended Standard Designations
The Electronic Industries Association (EIA) designations supersede the Recommended Standard (RS)
designations. References to the old designations may be shown when depicting actual text (e.g., RS-232)
displayed on Switch or the individual modem Web Server pages, serial remote interfaces, Telnet Command
Line Interfaces (CLIs), or unit rear panels. All other references in the manual refer to EIA designations.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Preface
Revision 14
xv
CAUTION: You should carefully review the following information.
Safety and Compliance
Electrical Safety and Compliance
The unit complies with the EN 60950 Safety of Information Technology Equipment (Including Electrical
Business Machines) safety standard.
The equipment is rated for operation at ±12 volts DC. It has a maximum power consumption of 4.5
Watts, and draws a maximum of 250 mA at +12 volts DC and 120 mA at -12 volts DC. The power supply
current is, in all circumstances, supplied by either a single Comtech EF Data modem, or a pair of these
modems.
CAUTION: IF THE UNIT IS OPERATED IN A VEHICLE OR MOVABLE INSTALLATION, MAKE
SURE THE UNIT IS STABLE. OTHERWISE, EN 60950 SAFETY IS NOT GUARANTEED.
Electrical Installation
CAUTION: CONNECT THE UNIT TO A POWER SYSTEM THAT HAS SEPARATE GROUND,
LINE AND NEUTRAL CONDUCTORS. DO NOT CONNECT THE UNIT WITHOUT A DIRECT
CONNECTION TO GROUND.
Operating Environment
CAUTION: DO NOT OPERATE THE UNIT IN ANY OF THESE EXTREME OPERATING
CONDITIONS:
•
AMBIENT TEMPERATURES LESS THAN 0° C (32° F) OR MORE THAN 50° C (122° F).
•
PRECIPITATION, CONDENSATION, OR HUMID ATMOSPHERES OF MORE THAN
95% RELATIVE HUMIDITY.
•
UNPRESSURIZED ALTITUDES OF MORE THAN 2000 METRES (6561.7 FEET).
•
EXCESSIVE DUST.
•
FLAMMABLE GASES.
•
CORROSIVE OR EXPLOSIVE ATMOSPHERES.
Equipment Connection
THE CRS-170A IS DESIGNED FOR OPERATION ONLY WITH THE COMTECH EF DATA
PRODUCTS IDENTIFIED IN THIS PREFACE UNDER ‘RELATED DOCUMENTS’. THESE
PRODUCTS SUPPLY DC OPERATING CURRENT (ELECTRONICALLY FUSED AND
PROTECTED) AND CONTROL SIGNALS FOR THE CORRECT FUNCTIONING OF THIS
SWITCH. CONNECTION TO OTHER MANUFACTURERS’ EQUIPMENT COULD RESULT
IN DAMAGE TO THE SWITCH. THE CRS-170A IS NOT COMPATIBLE WITH OTHER
COMTECH EF DATA MODEMS OR PRODUCTS NOT FEATURED IN THIS MANUAL.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Preface
Revision 14
xvi
South Korean Electromagnetic Compatibility
Unofficial translation:
Class A: EMC Registration is done on this equipment for business use only (Class A). Product seller and
user should notice that this equipment is not for household use.
European Union Radio Equipment and Telecommunications Terminal
Equipment (R&TTE) Directive (1999/5/EC) and EN 301 489-1
Independent testing verifies that the unit complies with the European Union R&TTE Directive, its
reference to EN 301 489-1 (Electromagnetic compatibility and Radio spectrum Matters [ERM];
ElectroMagnetic Compatibility [EMC] standard for radio equipment and services, Part 1: Common
technical requirements), and the Declarations of Conformity for the applicable directives, standards, and
practices that follow:
European Union Electromagnetic Compatibility (EMC) Directive
(2004/108/EC)
•
Emissions: EN 55022 Class A – Limits and Methods of Measurement of Radio Interference
Characteristics of Information Technology Equipment.
•
Immunity: EN 55024 – Information Technology Equipment: Immunity Characteristics, Limits,
and Methods of Measurement.
•
EN 61000-3-2 – Harmonic Currents Emission
•
EN 61000-3-3 – Voltage Fluctuations and Flicker.
•
Federal Communications Commission Federal Code of Regulation FCC Part 15, Subpart B.
CAUTION: TO ENSURE THAT THE UNIT COMPLIES WITH THESE STANDARDS, OBEY
THESE INSTRUCTIONS:
•
Use coaxial cable that is of good quality for connections to the L-Band Type ‘N’ Rx (receive)
female connector.
•
Use Type 'D' connectors that have back-shells with continuous metallic shielding.
•
Type ‘D’ cabling must have a continuous outer shield (either foil or braid, or both). The
shield must be bonded to the back-shell.
•
Operate the Switch and modems with their covers on at all times.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Preface
Revision 14
xvii
European Union Low Voltage Directive (LVD) (2006/95/EC)
Symbol
Description
Type of power cord required for use in the European Community.
CAUTION: Double-pole/Neutral Fusing
ACHTUNG: Zweipolige bzw. Neutralleiter-Sicherung
International Symbols
Symbol
Definition
Symbol
Definition
Alternating Current
Protective Earth
Fuse
Chassis Ground
For additional symbols, see the ‘Warnings, Cautions and Notes’ listed elsewhere in this
Preface.
European Union RoHS Directive (2002/95/EC)
This unit satisfies (with exemptions) the requirements specified in the European Union Directive
on the Restriction of Hazardous Substances in Electrical and Electronic Equipment (EU RoHS,
Directive 2002/95/EC).
European Union Telecommunications Terminal Equipment Directive
(91/263/EEC)
In accordance with the European Union Telecommunications Terminal Equipment Directive
91/263/EEC, the unit should not be directly connected to the Public Telecommunications
Network.
CE Mark
Comtech EF Data declares that the unit meets the necessary requirements for the CE Mark.
Product Support
For all product support, please call:
+1.240.243.1880
+1.866.472.3963 (toll free USA)
!
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Preface
Revision 14
xviii
Comtech EF Data Headquarters
http://www.comtechefdata.com
Comtech EF Data Corp.
2114 West 7th Street
Tempe, Arizona USA 85281
+1.480.333.2200
Warranty Policy
Comtech EF Data products are warranted against defects in material and workmanship for a
specific period from the date of shipment, and this period varies by product. In most cases, the
warranty period is two years. During the warranty period, Comtech EF Data will, at its option,
repair or replace products that prove to be defective. Repairs are warranted for the remainder
of the original warranty or a 90 day extended warranty, whichever is longer. Contact Comtech
EF Data for the warranty period specific to the product purchased.
For equipment under warranty, the owner is responsible for freight to Comtech EF Data and all
related customs, taxes, tariffs, insurance, etc. Comtech EF Data is responsible for the freight
charges only for return of the equipment from the factory to the owner. Comtech EF Data will
return the equipment by the same method (i.e., Air, Express, Surface) as the equipment was sent
to Comtech EF Data.
All equipment returned for warranty repair must have a valid RMA number issued prior to
return and be marked clearly on the return packaging. Comtech EF Data strongly recommends
all equipment be returned in its original packaging.
Comtech EF Data Corporation’s obligations under this warranty are limited to repair or
replacement of failed parts, and the return shipment to the buyer of the repaired or replaced
parts.
Limitations of Warranty
The warranty does not apply to any part of a product that has been installed, altered, repaired,
or misused in any way that, in the opinion of Comtech EF Data Corporation, would affect the
reliability or detracts from the performance of any part of the product, or is damaged as the
result of use in a way or with equipment that had not been previously approved by Comtech EF
Data Corporation.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Preface
Revision 14
xix
The warranty does not apply to any product or parts thereof where the serial number or the serial
number of any of its parts has been altered, defaced, or removed.
The warranty does not cover damage or loss incurred in transportation of the product. The
warranty does not cover replacement or repair necessitated by loss or damage from any cause
beyond the control of Comtech EF Data Corporation, such as lightning or other natural and
weather related events or wartime environments.
The warranty does not cover any labor involved in the removal and or reinstallation of
warranted equipment or parts on site, or any labor required to diagnose the necessity for repair
or replacement.
The warranty excludes any responsibility by Comtech EF Data Corporation for incidental or
consequential damages arising from the use of the equipment or products, or for any inability to
use them either separate from or in combination with any other equipment or products.
A fixed charge established for each product will be imposed for all equipment returned for
warranty repair where Comtech EF Data Corporation cannot identify the cause of the reported
failure.
Exclusive Remedies
Comtech EF Data Corporation’s warranty, as stated is in lieu of all other warranties,
expressed, implied, or statutory, including those of merchantability and fitness for a
particular purpose. The buyer shall pass on to any purchaser, lessee, or other user of
Comtech EF Data Corporation’s products, the aforementioned warranty, and shall indemnify
and hold harmless Comtech EF Data Corporation from any claims or liability of such
purchaser, lessee, or user based upon allegations that the buyer, its agents, or employees
have made additional warranties or representations as to product preference or use.
The remedies provided herein are the buyer’s sole and exclusive remedies. Comtech EF Data
shall not be liable for any direct, indirect, special, incidental, or consequential damages,
whether based on contract, tort, or any other legal theory.
Chapter 1. INTRODUCTION
1.1
Overview
Figure 1-1. CRS-170A L-Band 1:1 Redundancy Switch Module
The CRS-170A L-Band 1:1 Redundancy Switch Module (Figure 1-1) is an L-Band Tx-Rx IF signal switch. It is
designed for use with Comtech EF Data L-Band satellite modems in a 1:1 redundant (Online ‘A’ and Backup
‘B’) configuration.
The CRS-170A is compatible for use with the Comtech EF Data modem listed in Table 1-1. This table also
summarizes the CRS-170A 1:1 IF Switch applications, including requirements for supporting data switching
hardware and software.
The CRS-170A monitors the faults of the ‘A’ and ‘B’ modems and determines which modem should be
online. The data switch is built into each terrestrial data interface inside both modems (excluding the
CDM-600L [CLM-9600L] and SDM-300L3 modems, which require ancillary switching devices).
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–2
Table 1-1. CRS-170A Compatibility Summary
Modem
1:1 Data Switch
Firmware/Hardware RequirementNote 3
CDM-625A
Built into the CDM-625A
Firmware Ver. 1.1.1 or higher
CDM-625
Built into the CDM-625
Firmware Ver. 1.1.1 or higher
H64, H32, H16, or H8
Heights Remote Gateway
Built into the modem
Firmware Ver. 2.5.1 or higher
Advanced VSAT CDM-850
Built into the CDM-850
Firmware Ver. 1.7.1.X or higher
Advanced VSAT CDM-840
Built into the CDM-840
Firmware Ver. 1.2.4 or higher
CDM-760
Built into the CDM-760
Firmware Ver. 1.1.1 or higher
CDM-750
Built into the CDM-750
Firmware Ver. 1.1.1 or higher
CDM-570AL
Built into the CDM-570AL
Firmware Ver. 1.1.1 or higher
CDM-570AL w/Optional IP
Packet Processor
User-provided hub or Layer 2 switch
Firmware Ver. 1.2.1 or higher
CDM-570L
Built into the CDM-570L
Firmware Ver. 1.6.7 or higher
CDM-570L 2/optional IP
Module
User-provided hub or Layer 2 switch
Firmware Ver. 1.5.4.2 or higher
CDM-710GL
Built into the CDM-710GL
Firmware Ver. 5.1.1 or higher
CDM-710 (L-Band version) Built into the CDM-710
Firmware Ver. 2.4.1 or higher;
Chassis Rev. A or higher
CDM-700 (L-Band version) Built into the CDM-700
Firmware Ver. 1.1.6 or higher;
Chassis Rev. A or higher
CDM-600L (CLM-9600L)
CRS-150Note 1
Firmware Ver. 1.1.4 or higher;
Hardware Rev. 3 or higher
SDM-300L3
SMS-301Note 1
Special version of SMS-301
1) See Section 1.3.3 for CRS-170A►Modem►Ancillary Switch interoperation information.
For detailed information about the CRS-150 and SMS-301 switches, see their respective
Installation and Operation Manuals:
• CRS-150 1:1 Redundancy Switch Installation and Operation Manual
(CEFD P/N MN/CRS150.IOM)
• SMS-301 Redundancy Switch Installation and Operation Manual
(CEFD P/N MN/SMS301.IOM)
2) This switch and its paired modems use Type ‘N’ connectors for L-Band operation.
3) Firmware updates are free and may be downloaded from the Comtech EF Data web site
(www.comtechefdata.com). If a modem does not meet the hardware requirements,
contact Comtech EF Data Product Support – hardware revision upgrades must be
performed at CEFD.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–3
1.2
Physical Features
1.2.1
Modem Side Features
Figure 1-2 shows the modem side of the CRS-170A. The connectors provided here facilitate all necessary
external connections between the CRS-170A and the compatible Comtech EF Data modems.
J6 TX B
J5 TX A
J3 Control A
J4 Control B
J2 RX B
J1 RX A
Ref Des
Name
Connector Type
Function
Chapter Section
J1
Rx A
Type ‘N’
Input to Modem ‘A’
3.2.1.1
J2
Rx B
Type ‘N’
Input to Modem ‘B’
3.2.1.1
J3
Control A
DB-9F 9-pin Type ‘D’ female
Modem ‘A’ Control Interface
3.2.1.2
J4
Control B
DB-9F 9-pin Type ‘D’ female
Modem ‘B’ Control Interface
3.2.1.3
J5
Tx A
Type ‘N’
Output from Modem ‘A’
3.2.1.1
J6
Tx B
Type ‘N’
Output from Modem ‘B’
3.2.1.1
Figure 1-2. CRS-170A – Modem Side Connectors
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–4
1.2.2
Top and Antenna Side Features
Figure 1-3 shows the CRS-170A top and antenna side features and the chapters that provide more
detailed information.
Feature
Description
Chapter Section
1
4X #6-32 holes for vertical rack mounting (used with Switch Mounting Kit KT/11708)
2.2
2
4X #6-32 holes for horizontal rack mounting (used with Switch Mounting Kit KT/11708)
2.2
3
Ground Stud
2.2, 3.2.2.2
4
“Switch Conditions” DIP Switches
1.3.1, 4.10
5
J7 | Rx Type ‘N’ Input Connector
3.2.2.1
6
J8 | Tx Type ‘N’ Output Connector
3.2.2.1
7
Online LED Indicators
1.3.1
Figure 1-3. CRS-170A – Top and Antenna Side Features
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–5
1.3
Functional Description
The CRS-170A performs the Tx and Rx coaxial switching required for redundant modem operation with
an outdoor BUC and LNB.
The Tx (transmit) side switches four modem output signals that are multiplexed onto the transmit coaxial
cable:
•
950-2250 MHz L-band transmit RF;
•
10 MHz BUC frequency reference;
•
600 KHz BUC FSK control and status communication;
•
BUC DC power supply.
The Rx (receive) side of the switch uses both power dividers and relays to provide the redundant modem
interface for three signals multiplexed onto the LNB coaxial cable:
•
950-2250 MHz L-band receive RF from LNB;
•
10 MHz frequency reference to LNB;
•
DC power supply to LNB.
1.3.1
Switch / Modem Operation
The CRS-170A is configured with two modems to form a complete 1:1 redundant modem system. Within
the CRS-170A, a redundancy controller continually monitors the status of faults for both modems to
determine which modem should be Online and Offline. The control cables between the modems and the
CRS-170A include four signal groups:
•
First, serial full-duplex communication lines are routed from one modem to the other modem
via the CRS-170A. Using these lines, this Online unit can interrogate the Offline unit at regular
intervals to determine its configuration. If a difference in configuration is detected, the Online
unit will reconfigure the Offline unit so that the configurations are always synchronized. This
process is entirely automatic – if the Offline unit is replaced, it does not have to be manually
reprogrammed to match the Online unit.
•
Second, the Modem’s Unit, Tx and Rx faults signals from both modems are routed to the CRS-
170A. This allows the redundancy controller to always know the health status of both modems.
•
Third, the online/offline signals are routed from the CRS-170A to each modem. Based on the
modem faults, the CRS-170A will determine which modem should be Online and Offline. In the
event that both modems indicate faults through some malfunction, the CRS-170A switch will
select, by default, Modem ‘A’.
•
Fourth, +12V is routed from each modem to the CRS-170A for operational power. This power
from both modems is diode OR’d so that the switch remains active if power is lost from one of
the modems.
Mode Switches – The Mode DIP switches, located on the antenna side of the CRS-
170A, allow the switch to operate in two different modes – Normal (Intelligent
Controller) Mode and SDM-300L/CDM-600L (Dumb Controller) Mode:
•
Use Normal (Intelligent Controller) Mode for the CDM-625A or CDM-
625, H64/H32/H16/H8 Heights Remote Gateway, Advanced VSAT
CDM-850 or CDM-840, CDM-760, CDM-750, CDM-710GL, CDM-710, CDM-
700, and CDM570L/AL modems.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–6
•
Use SDM-300L/CDM-600L (Dumb Controller) Mode for SDM-300L and CDM-600L (CLM-9600L)
modems.
IF Switching – The CRS-170A provides L-Band redundancy, but when switching occurs, it accommodates
more than just the L-Band signals:
•
On the Tx side, it switches the Tx L-Band signal, the 10 MHz reference to the BUC, DC power to
the BUC and, on CDM-570L modems, FSK signaling to the BUC.
•
On the Rx side, it switches the 10 MHz reference to the LNB, and DC power to the LNB. The Rx L-
Band signal from the LNB is split in a power divider to continuously drive both the Online and
Offline demodulator. The Offline demodulator can then maintain lock so that it is ready to
quickly assume Online status for receive traffic when a switchover is required.
Data Switching is accomplished inside each modem, in the data interface itself. A ‘Y’ cable connects
both the Online unit and the Offline unit to the terrestrial data source. Transmit data drives both
modems in parallel so that the Backup modulator is always ready to come Online. Termination
impedance for the modem line receivers is active in the Online unit. On the Rx side of the interface, TRI-
STATE® control of the Offline unit line drivers keeps the Offline unit from interfering with the Rx data
traffic. Send timing output from the Offline unit is also TRI-STATE®1.
The Offline Modem holds its Rx terrestrial data in TRI-STATE® as commanded by the CRS-170A
Switch. Because of this, it is very important to power down the Offline Modem before
disconnecting the modem from the Switch.
Manual Switching is user-enabled locally via the Online unit; locally using the modem’s front panel, or
remotely using serial remote control or the modem’s Web Server (HTTP) Interface.
You must control Automatic Switching Selection via the Online unit. Use the
CRS-170A Switch Conditions Unit+Tx and Unit+Rx DIP switches, located on the
antenna side of the CRS-170A, to configure the conditions that cause an
automatic switchover. These settings provide a great deal of flexibility in the
operation of the switch: you can select between Modem Unit faults only; Modem
Unit faults or Receive Traffic faults; Modem Unit faults or Transmit Traffic faults;
or all three.
Section 4.10 CRS-170A DIP Switch Settings
Two green LEDs are located on the antenna side of the CRS-170A. They provide a visual identifier for the
Online unit.
With the ‘bridging’ architecture of the CRS-170A (whereby identical terrestrial data traffic signals are
routed to both Online and Offline units), the redundancy controller can avoid unnecessary switchovers.
By examining the fault status of both modems, it can infer if the fault is external to the system. For
example, you have configured the CRS-170A to switch following Unit Faults or Transmit Traffic Faults,
and your modems have been configured for external clock operation. Now, suppose that the external
equipment (network, multiplex, router, etc.) fails – both the Offline and Online units will now show a
Transmit Traffic fault (No Clock Detected from Terrestrial Port). The CRS-170A Controller State Machine
1 TRI-STATE is a registered trademark of National Semiconductor.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–7
will see that both faults have occurred at the same time (i.e., within a 0.5 second window), and infers
that the fault is external. Therefore, no unnecessary switchover is initiated.
1.3.2
1:1 IP Redundancy Data Switching
1.3.2.1
Managed Switch Mode for CDM-625A or CDM-625, Heights Remote
Gateway, Advanced VSAT CDM-850 or CDM-840, CDM-760, CDM-
750, CDM-710GL, CDM-710, or CDM-700
A standard, user-provided Ethernet Layer 2 Switch is needed if any of the modems listed here are
configured for Managed Switch Mode (also known as “Ethernet Bridge Mode”) terrestrial traffic.
A Layer 2 Switch is designed to limit the traffic that egresses each port by only sending Ethernet packets
out the port that the destination network device is located. The switch maintains a table - known as the
dynamic Content-Addressable Memory (CAM) table - that maps MAC addresses to switch ports. When a
packet arrives, in which an entry for that specific destination MAC is unknown to the switch, it sends the
packet out all ports and waits for response packets in an attempt to identify which port that particular
MAC resides. Once the device responds, the switch is able to map the MAC to the port in the CAM table.
Any new arriving packets destined for that MAC address will be forwarded only out the port identified in
the CAM table. Most switch CAM tables do have a flush or timeout value, but is normally set to a very
high number to limit the amount of times the switch has to broadcast a packet out all ports. It is also
important to note that CAM entries for a specific port are cleared when a port link goes down.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–8
Figure 1-4. 1:1 IP Redundancy Managed Switch Mode for CDM-625A or CDM-625, Heights
Remote Gateway, Advanced VSAT CDM-850 or CDM-840, CDM-760, CDM-750,
CDM-710GL, CDM-710, or CDM-700
Figure 1-4 shows a Managed Switch Mode 1:1 IP Redundancy setup with the Ethernet data interface of both
modems connected to a Layer 2 Switch. Both modems are operational – Modem ‘A’ is Online and connected
to Port 4 of the Layer 2 Switch. Modem ‘B’ is Offline and connected to Port 3 of the Layer 2 Switch, but the
Ethernet link is not active because only the Online unit will have an active Ethernet data interface. Also, Local
PC ‘A’ is connected to Port 1 of the Layer 2 Switch.
When Ethernet traffic is sent from Local PC ‘A’ across the satellite link to remote PC ‘B’, the Layer 2
Switch will “learn” the MAC addresses of both PCs and will have these dynamic entries in its CAM Table:
Port 1 MAC 00-00-00-00-00-11 (Local PC ‘A’)
Port 3 No entries, port down
Port 4 MAC 00-00-00-00-00-22 (Remote PC ‘B’)
As shown in Figure 1-5, in the event of a fault on the Online unit ‘A’, the following will occur:
•
Modem ‘A’ goes offline and disables its Ethernet data interface.
•
Simultaneously, Modem ‘B’ goes online and enables its Ethernet data interface.
•
Layer 2 Switch ‘A’ senses that Port 4 is no longer active and clears the CAM table entries for that
port.
•
When the next Ethernet packet from Local PC ‘A’ destined for Remote PC ‘B’ arrives at Switch
‘A’, there is no CAM entry for the PC ‘B’ MAC, so it will be broadcast to all active ports.
•
When the next Ethernet packet from Remote PC ‘B’ arrives at Switch ‘A’, Switch ‘A’ dynamically
adds the PC ‘B’ MAC to the CAM table for Port 3.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–9
Figure 1-5. 1:1 IP Redundancy Managed Switch Mode – Switchover for CDM-625A or
CDM-625, Heights Remote Gateway, Advanced VSAT CDM-850 or CDM-840, CDM-760,
CDM-750, CDM-710GL, CDM-710, or CDM-700
Note the following:
1) The Managed Switch Mode method of redundancy is intended to be equivalent to pulling the
Ethernet cable from one port and putting it into a different port on the same switch.
2) For the CDM-625A or CDM-625 modems, you may configure one of the modem’s four available
10/100 Ethernet ports for M&C Ethernet. As configured in Dedicated Management Port Mode,
when the modem is offline the M&C-designated port remains functional and available for
operation, while the three remaining ports are unavailable. Otherwise, if none of the 10/100
Ethernet ports are reserved for M&C operation; all four ports become unavailable when the
modem is offline.
This configuration must be enabled on both modems. See the CDM-625A or the
CDM-625 Advanced Satellite Modem Installation and Operation Manual (CEFD
Part No. MN-CDM625A or MN-CDM-625) for instructions to configure one of the
four 10/100 Ethernet ports for each modem for remote Ethernet M&C.
Dedicated Management Port Mode is not configurable for use when the optional
IP Packet Processor is installed and enabled. With the IP Packet Processor
enabled, as a means to avoid Ethernet Networking Loops, only one of the
CDM-625A or CDM-625’s four 10/100 Ethernet ports is used for each modem at
any given time.
3) For CDM-760, CDM-750, CDM-710GL, CDM-710, or CDM-700 modems, when the modem is
offline, although all GigE port(s) are unavailable, the M&C Ethernet port remains functional and
available for operation.
4) Installation must use a true switching device, not a hub device.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–10
1.3.2.2
Router Mode For CDM-625A or CDM-625 WITH Optional IP Packet
Processor
All configuration changes can only be made to the Online unit and will require you to “Save
Parameters to permanent storage” to ensure the configuration change is also applied to the
Backup Modem.
For the CDM-625A or CDM-625 with the optional IP Packet Processor installed and enabled and the
configuration set for Router Mode, you need to provide an external Ethernet switch.
In Router Mode, both modems must be assigned a unique Management IP address on the same subnet
(172.18.10.21/24 and 172.18.10.22/24 as shown in Figure 1-6 and Figure 1-7). This is used to share the
parameters file. A Traffic IP address on the subnet must also be assigned (172.18.10.20/24) in the Online
unit.
The Traffic IP Address must be different from either Management IP Address.
Whichever modem is Online will assume the Traffic IP. When there is a switchover to the backup
modem, this modem will now assume the Traffic IP.
Figure 1-6. CDM-625A or CDM-625 1:1 IP Redundancy Router Mode – ‘A’ Online
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–11
Per Figure 1-7, the backup modem will also broadcast a “gratuitous ARP” which will tell all local devices
to now associate a new MAC address for the Traffic IP 172.18.10.20. Each device will update their ARP
tables and traffic will resume virtually instantaneously.
Figure 1-7. CDM-625A or CDM-625 1:1 IP Redundancy Router Mode Switchover (‘B’
Online)
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–12
1.3.2.3
Managed Switch or Router Modes for CDM-570L/AL WITH Optional
IP Module or Packet Processor
•
Do not use the M&C Ethernet port (bottom RJ-45 connector) when the optional IP Module
is installed.
•
All configuration changes can only be made to the Online unit and will require you to
“Save Parameters to permanent storage” to ensure the configuration change
is also applied to the Backup Modem.
Managed Switch (Ethernet Bridge) Mode: For the CDM-570L/AL in Managed Switch Mode (also known
as “Ethernet Bridge Mode”) you MUST use an external Ethernet hub to insure that traffic will continue
after a switchover. If an Ethernet switch is used, there could be a several minute outage while the
Ethernet Switch “re-learns” the correct output Ethernet port. Using a “dumb” Ethernet hub allows LAN-
to-WAN traffic to continue even after a switchover occurs since both modems will be receiving the LAN
traffic.
In Managed Switch Mode, both modems should be assigned a unique Management IP address on the
same subnet in order to share the parameter file.
Router Mode: For the CDM-570L/AL in Router Mode, you should use an external Ethernet switch.
Router mode does not require a “dumb” hub as with Managed Switch Mode and, for performance
reasons, an Ethernet switch is highly recommended.
In Router Mode, both modems must be assigned a unique Management IP address on the same subnet
(172.18.10.21/24 and 172.18.10.22/24 as shown in Figure 1-8 and Figure 1-9). This is used to share the
parameters file. A Traffic IP address on the subnet must also be assigned (172.18.10.20/24) in the Online
unit.
Whichever modem is Online will assume the Traffic IP. When there is a switchover to the backup
modem, this modem will now assume the Traffic IP. As shown in Figure 1-9, the backup modem will also
broadcast a “gratuitous ARP” that will tell all local devices to now associate a new MAC address for the
Traffic IP 172.18.10.20. Each device will update their ARP tables and traffic will resume virtually
instantaneously.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–13
Figure 1-8. CDM-570L/AL 1:1 IP Redundancy Router Mode – ‘A’ Online
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–14
Figure 1-9. CDM-570L/AL 1:1 IP Redundancy Router Mode Switchover – ‘B’ Online
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–15
1.3.3 CRS-170A Operation with CDM-600L (CLM-9600L) and SDM-300L3
Modems
The CDM-600L (CLM-9600L) and SDM-300L3 modems do not have built-in switching capability for the
terrestrial data side of the link:
•
For the CDM-600L (CLM-9600L), 1:1 redundancy requires both a CRS-150 switch to act as
controller and terrestrial data switch and a CRS-170A to perform the L-Band switching. The
CRS-170A is required because the CRS-150 RF switching is limited to the L-Band band, and will
not handle the high current BUC power supply multiplexed onto the transmit coaxial cable.
•
Similarly, the SDM-300L3 requires an SMS-301 switch together with the CRS-170A.
In both cases, the CRS-170A is controlled by the supporting data switch, and places the ‘A’ or ‘B’ modem RF
Online to match the data switch state. The CDM-600L (CLM-9600L) modems supply redundant power to
the CRS-170A through the CRS-150. The SMS-301 itself has redundant power supplies, and feeds power to
the CRS-170A through the control cable. Online/Backup Modem configuration matching is provided by the
CRS-150 controller communication with the CDM-600L (CLM-9600L) modem. The SMS-301 does not
automatically configure the Backup Modem.
Operation with two CDM-600L (CLM-9600L) modems requires an additional CRS-150 1:1 switch for
terrestrial data switching and 1:1 control, while operation with two SDM-300L3 modems requires an
additional SMS-301 1:1 switch to handle terrestrial data and control. Thus, there are three functional
configurations for the CRS-170A.
1.3.3.1
Operation with CDM-600L (CLM-9600L) Modems and CRS-150
Switch
CRS-150 1:1 Redundancy Switch Installation and Operation Manual (CEFD P/N
MN/CRS150.IOM)
THE CRS-150 IS AN ACCESSORY PRODUCT DESIGNED SPECIFICALLY FOR THE COMTECH EF
DATA CDM-600 AND CDM-600L (CLM-9600L) MODEMS, AND MUST NOT BE USED WITH ANY
OTHER EQUIPMENT.
Figure 1-10. CRS-150 1:1 Redundancy Switch
The CRS-150 1:1 Redundancy Switch (Figure 1-10) connects to Online and Backup modems, monitors the
fault status of these units, and controls the routing of data to and from the units. IF signals, 10MHz
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–16
reference signals, DC power for the BUC and LNB, and FSK signaling to the BUC are switched in the CRS-
170A under control of the CRS-150. In the case of an equipment failure, automatic switching takes place
to protect the traffic circuit.
At the heart of the CRS-150 is a Controller State Machine that is responsible for fault monitoring and
control of switching functions – it is implemented in a Complex Programmable Logic Device (CPLD).
The CRS-150 derives its operating power from the Online and Backup modems via extra power-carrying
wires in the data cable from each modem. Similarly, the CRS-170A derives its +12V power from both
modems through 'Y' cable connection to the same cables. The required online and offline control signals
are also included in these cables. A diode sharing arrangement with a current sharing circuit ensures
that power is taken equally from the two modems in normal operation.
In the event that one of the two units is removed, however, the remaining modem can supply all current
requirements. The modems supply +12 volts DC (at a combined total of 400 mA max) and -12 volts DC
(at a combined total of 120 mA max). Maximum power consumption occurs in a serial LVDS mode at
maximum data rate (20 Mbps). Power consumption in EIA-232 modes is approximately 40% of the
maximum values. The modem employs electronic fuses that prevent excessive current from being
drawn by the CRS-150 should an anomalous condition occur.
Transmit Clock and Data signals entering the CRS-150 via the Data Interface are buffered and fed to both
modems simultaneously; this parallel feed ensures that the Backup unit sees the same traffic conditions
as the ONLINE unit. Rx Data and Clock signals coming from the ONLINE unit are routed through signal
relays to the Data Interface. In the event that a switchover occurs, these relays switch so the Backup unit
then supplies the Data and Clock signals.
As only one modem in the pair (the Online unit) is permitted to transmit its IF carrier signal at any one
instant, the Backup unit is forced to disable its Tx carrier by asserting the Tx Carrier Off signal at the Data
Interface. Additionally, the CRS-170A provides further isolation and security by using an RF relay within
the unit.
The Rx IF signal is fed to both modems simultaneously through the power divider in the CRS-170A. This
divider introduces a loss of approximately 3.5 dB but, given the wide dynamic range of the demodulator
in the CDM-600L (CLM-9600L), this is not considered to be a problem. The advantage of this scheme is
that the demodulators in both Online and Backup units are locked, and therefore if a switchover does
occur, there will be no delay while waiting for the demodulator to acquire lock.
Fault status information is fed from the Online and Backup modems via the Data Interface connector.
Based on the fault status, the Controller State Machine in the CRS-150 decides whether the ‘A’ or ‘B’
unit is to be the ONLINE unit. It asserts a control signal to the Backup unit, which mutes its Tx IF carrier
and simultaneously indicates to the microcontroller within the Backup unit that the unit is no longer
‘Online’. Consequently, the ‘Online’ LED on the front panel of the Backup Modem is extinguished and
the Backup status is also reported over the remote control bus so an external M&C system can
determine the state of the redundancy system. At the same time, a green LED will illuminate on the
front of the CRS-150 to indicate whether the ‘A’ or ‘B’ unit is Online, and the green LEDs on the antenna
side of the CRS-170A will indicate the same status.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–17
Set the DIP switches on the CRS-170A antenna side to establish modem-
specific operation. For the CDM-600L (CLM-9600L), place the Mode switch
in the SDM-300L/CDM-600L (Dumb Controller) position and push the
Switch Condition switches to the OFF position.
Section 4.10 CRS-170A DIP Switch Settings
1.3.3.2
Operation with SDM-300L3 Modems and SMS-301 Switch
SMS-301 Redundancy Switch Installation and Operation Manual
(CEFD P/N MN/SMS301.IOM)
Figure 1-11. Comtech EF Data SMS-301 1:1 Redundancy Switch
The SMS-301 1:1 Redundancy Switch (Figure 1-11) is modified from the standard version that operates
with 70/140 MHz IF SDM-300A modems. All operation as a 70/140 MHz modem switch applies except
that the RF switching is done in the CRS-170A. The BNC IF connectors are replaced by Type ‘N’
connectors, as BNC connectors and internal switching are not suitable for L-Band operation. Signals on
the ‘J14 | Status/Faults’ connector are modified to provide +12VDC power output and A/B switch
control outputs to the CRS-170A. The SMS-301 has its own redundant power supplies, so the CRS-170A
receives redundant power.
Operation here is similar to operation of the CRS-150 1:1 Redundancy Switch with CDM-600L (CLM-
9600L) Online and Backup modems. The SMS-301 operates as the principal switch and controller, with
the CRS-170A providing the required switching for L-Band signals, references, and power supplies that
the SMS-301 cannot handle.
The SMS-301 connects to the Online and Backup SDM-300L3 modems, monitors the fault status of these
two units, and controls the routing of data to and from the units. IF signals, 10MHz reference signals, DC
power for the BUC and LNB, and FSK signaling to the BUC are switched in the CRS-170A under control of
the SMS-301. In the case of equipment failure, automatic switching takes place to protect the traffic
circuit.
Set the DIP switches on the CRS-170A antenna side to establish modem-
specific operation. For the SDM-300L3, place the Mode switch in the
SDM-300L/CDM-600L (Dumb Controller) position and push the Switch
Condition switches to the OFF position.
Section 4.10 CRS-170A DIP Switch Settings
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–18
1.4
Summary of Specifications
Equipment Type
L-Band 1:1 Redundancy Switch
Manufacturer
Comtech EF Data, Tempe, Arizona
Supported Comtech EF Data Modems
•
CDM-625A or CDM-625 Advanced Satellite Modem with/without
optional IP Packet Processor
•
H64/H32/H16/H8 Heights Remote Gateway
•
Advanced VSAT CDM-850 or CDM-840 Remote Router
•
CDM-760 Advanced High-Speed Trunking Modem
•
CDM-750 Advanced High-Speed Trunking Modem
•
CDM-570AL L-Band Satellite Modem with/without optional IP Packet
Processor
•
CDM-570L L-Band Satellite Modem with/without optional IP Module
•
CDM-710GL L-Band High-Speed Satellite Modem
•
CDM-710 L-Band Broadcast Satellite Modem
•
CDM-700 L-Band Satellite Modem
•
CDM-600L (CLM-9600L) with CRS-150 1:1 Data Switch
•
SDM-300L3 with SMS-301 1:1 Data Switch
Operating Modes
•
Fully automatic under control of supporting 1:1 switch.
•
Manual under control of supporting 1:1 switch.
Architecture
•
Full bridging architecture when supported by CRS-150, or SMS-301
data switching and control, with configuration synchronization.
•
Tx redundancy supports all BUC interface signals (RF, 10 MHz
reference, FSK communications, and power supply)
•
Rx IF signal fed to both Online and Backup units. Rx switching
supports all LNB interface signals (RF, 10 MHz reference, and power
supply.)
Switch Conditions
Tx/Rx switching follows state of supporting data switching via control input
from data switch.
IF Switching / Splitting
•
Tx IF: Switched by RF relay (1.5 dB max loss, 40 dB min ON/OFF
isolation)
•
Rx IF: Passive power splitting (7 dB max loss)
BUC Power Switching
Switched by power relay (60VDC max, 4A max)
BUC 10 MHz Reference Switching
Switched by relay (1 dB max loss, 70dB min ON/OFF isolation)
BUC FSK Comms Switching
Switched by relay (70dB min ON/OFF isolation)
LNB Power Switching
Switched by power relay (28 VDC max)
LNB 10 MHz Reference Switching
Switched by relay (1 dB max loss)
Tx-Rx Isolation
90dB min, 950-2250 MHz
IF Impedance
Optimized for 50Ω (> 10 dB return loss on external IF ports)
IF Connectors
50Ω Type N Female
IF Frequency Range
950-2250 MHz
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Introduction
Revision 14
1–19
Weight
1.1lbs (0.5kg)
Dimensions [excluding connectors]
1.7 H x 5.7 W x 4.1 D inches (43 H x 143 W x 104 D mm)
Optional 19-inch rack mounting kit available.(CEFD P/N KT/11708)
Power requirements
•
+ 12 volts DC @ 130 mA (max)
•
Power supplied by modems or from the CRS-150 1:1 Redundancy
Switch (when used in tandem with the CDM-600L [CLM-9600L]
modem), or from the SMS-301 1:1 Redundancy Switch (when used
in tandem with the SDM-300L modem).
Approvals
‘CE’ as follows:
•
EMC
•
Safety
Chapter 2. INSTALLATION
2.1
Unpack and Inspect the Shipment
The CRS-170A L-Band 1:1 Redundancy Switch module and its optional Installation and Operation Manual
(otherwise available online at http://www.comtechefdata.com) were packaged and shipped in a
reusable cardboard carton containing protective foam spacing.
CAUTION: THIS EQUIPMENT CONTAINS PARTS AND ASSEMBLIES SENSITIVE TO
DAMAGE BY ELECTROSTATIC DISCHARGE (ESD). USE ESD PRECAUTIONARY
PROCEDURES WHEN HANDLING THE EQUIPMENT.
Once opened, inspect the shipment:
Step
Task
1
Keep all shipping materials.
2
Check the packing list to make sure the shipment is complete.
3
Inspect the equipment for damage. If damage exists, immediately contact the
carrier and Comtech EF Data to submit a damage report.
4
Read the manual.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Installation
Revision 14
2–2
2.2
Mount the Unit
The CRS-170A switch module’s small size and weight allow it to be freestanding. You may choose to let
the module hang freely, supported only by the interfacing cables.
Comtech EF Data KT/11708 Switch Mounting Kit
CEFD P/N
Qty
Description
FP/PN11575-1
1
Switch Mounting Panel
HW/6-32X3/8FLT
4
#6-32 x 3/8” LG SS Flat Head Machine Screw
Figure 2-1. Optional KT/11708 Switch Mounting Kit
You may also mount the module into a 1RU space at the front or rear of the rack enclosure that houses
the modems. The optional Comtech EF Data KT/11708 Mounting Panel Kit is available for this purpose.
As shown in Figure 2-1, the module can be installed vertically or horizontally to the kit’s slotted
mounting panel. User-supplied screws are then required to secure the panel to the rack enclosure
threaded mounting rails.
CAUTION: PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be connected
to the protective earth connection at all times. It is therefore imperative that the Switch and its
paired modems are properly grounded – using the ground stud provided on the Switch antenna
side panel and the ground studs located on the modem rear panels – during installation,
configuration, and operation.
Chapter 3. SWITCH CONNECTORS
AND PINOUTS
3.1
Cabling Connection Types
The cable and connector types described in this section are commonly used in many Comtech EF Data
products. Each cable type is typically dedicated to a specific mode of operation.
The CRS-170A L-Band 1:1 Redundancy Switch and its compatible Traffic and Redundant Modems may
not use all of these connector types.
The European EMC Directive (EN55022, EN50082-1) requires that you use properly shielded
cables for DATA I/O. These cables must be double-shielded from end-to-end, ensuring a
continuous ground shield.
3.1.1 Coaxial Cable Connections
Figure 3-1 show the coaxial cables (plugs) and their mating connectors (jacks/sockets) that Comtech EF
Data uses with their products: ‘BNC’, ‘TNC’, ‘N’, ‘F’, and ‘SMA’.
Coupling Type
Connector Type
Plug (Male)
Jack (Female)
Bayonet
(Type ‘BNC’ shown)
Threaded
(Type ‘N’ shown)
Figure 3-1. Coaxial Connector Examples
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Switch Connectors and Pinouts
Revision 14
3–2
These connectors are available in two coupling styles: Bayonet or Threaded:
•
Bayonet Coupling Style – The jack has a pair of guideposts that accommodate the plug’s
lockdown slots. This lockdown design provides secure assembly without over-tightening the
connection.
•
Threaded Coupling Style – The jack features external threads. The plug shell features internal
threads, and has either a knurled outer surface to permit hand-tightening of the connection, or
hex flats to accommodate torqued installation.
Connection Instructions:
•
Bayonet Coupling Connections – Use the plug slots to guide, then slide the plug onto the jack
posts. Then, turn the plug clockwise until the jack posts are fully seated within the plug slot.
•
Threaded Coupling Connections – Engage the plug onto the jack threads, and then turn the plug
clockwise until it is fully threaded onto the jack. Do not over-tighten the connection.
3.1.1.1
Type ‘BNC’
BNC connectors feature a Bayonet Coupling design.
3.1.1.2
Type ‘TNC’
TNC connectors feature a Threaded Coupling design similar to Type ‘N’, Type ‘F,’
and Type ‘SMA’ connectors.
3.1.1.3
Type ‘N’
Type ‘N’ connectors feature a Threaded Coupling design similar to Type ‘TNC’,
Type ‘F’, and Type ‘SMA’ connectors.
3.1.1.4
Type ‘F’
Type ‘F’ connectors feature a Threaded Coupling design similar to Type ‘TNC’,
Type ‘N’, and Type ‘SMA’ connectors.
3.1.1.5
Type ‘SMA’ (Subminiature Version ‘A’)
Type ‘SMA’ connectors feature a Threaded Coupling design similar to Type
‘TNC’, Type ‘N’, and Type ‘F’ connectors.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Switch Connectors and Pinouts
Revision 14
3–3
3.1.2 D-Subminiature Cable Connections
Type ‘D’ Connection Type
Example
Chassis Receptacles:
(TOP) Female
(BOTTOM) Male
Type ‘D’ Cable With Jack Screws
(Female Shown)
Figure 3-2. D-Subminiature Connector Examples
D-Subminiature connectors are also called Type ‘D’ or ‘D-Sub’ connectors. The connector pair features
multiple rows of pins (male side) coupled to mating sockets (female side). The cable plug and chassis
receptacle each feature a D-shaped profile that interlock to ensure proper pin orientation and connector
seating.
Either chassis receptacle gender features two jack nuts for secure assembly of the cable plug to the
chassis receptacle.
Whether its gender is male or female, the cable plug features two jack screws for secure connection to
the jack nuts provided on the mating chassis receptacle. The jack screws may be hand tightened or
tightened with a standard flat-blade screwdriver.
Connection Instructions: Orient the plug to the receptacle in the proper position. Press firmly into place.
Use the jack screws to secure the plug to the receptacle jack nuts. Do not over-tighten.
About connector pinout tables: Figure 3-2 identifies the Pin 1 location for either gender connector.
Unless noted otherwise, the connector pinout tables provided in this manual arrange/order information
(i.e., the Pin # column/row) based on this orientation.
3.1.3 RJ-45, RJ-48 Cable Connections
The plug for an RJ-45 or RJ-48 cable features a flexible tab. The RJ-45 or RJ-
48 jack features a mating slot. This design configuration assures proper
installation and pin orientation.
Connection Instructions: Press down the tab on the cable plug, and then insert the plug into the RJ-4x
jack. The connection is complete when the tab ‘clicks’ into position inside the jack.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Switch Connectors and Pinouts
Revision 14
3–4
3.2
CRS-170A User Connectors
3.2.1 Modem Side Connectors
The modem side connectors (Figure 3-3) provide all necessary external connections between the CRS-
170A and the compatible Comtech EF Data modems.
J6 Tx B
J5 Tx A
J3 Control A
J4 Control B
J2 Rx B
J1 Rx A
Figure 3-3. CRS-170A – Modem Side Connectors
3.2.1.1
IF Connectors (50Ω Type ‘N’)
Four 50Ω Type ‘N’ female connectors are provided on the modem side of the CRS-170A.
Table 3-1. Modem Side Type ‘Type ‘N’ Connectors
Ref Des
Name
Description
Direction
J1
Rx A
RX-IF signal
Out
LNB 10 MHz Ref
In
LNB Power
In
J2
Rx B
RX-IF signal
Out
LNB 10 MHz Ref
In
LNB Power
In
J5
Tx A
TX-IF signal
In
BUC 10 MHz Ref
In
BUC FSK Comm.
In/Out
BUC Power
In
J6
Tx B
TX-IF signal
In
BUC 10 MHz Ref
In
BUC FSK Comm.
In/Out
BUC Power
In
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Switch Connectors and Pinouts
Revision 14
3–5
3.2.1.2
J3 | Control Connector (Top) – Modem ‘A’ (DB-9F)
The Modem ‘A’ Control connector is a 9-pin Type ‘D’ female interface. Pins 2, 3, and 4
carry signals looped through the switch module from Modem ‘B’ to Modem ‘A’, while
pins 6, 7, and 8 loop the same signals from Modem ‘A’ through to Modem ‘B’. The
12VDC input, which is diode OR’ed with the corresponding 12VDC input from
Modem ‘B’, powers the switch module.
Table 3-2. J3 | Control A Modem Connector Pinouts
Pin
Signal Name
Signal Function
Direction
5
Ground
Signal Ground
---
9
+12VDC
+12 VDC
In
4
ONLINE_A
Modem ‘A’ Online
Out
8
SERIAL_FAULT_A
Modem ‘A’ Serial Faults
In
3
CLK_OUT_B
Modem ‘B’ Clk Out
Out
7
CLK_IN_A
Modem ‘A’ Clk In
In
2
AUX_SER_TX_B
Modem ‘B’ Tx Comms
Out
6
AUX_SER_TX_A
Modem ‘A’ Tx Comms
In
1
Ground
Signal Ground
---
3.2.1.3
J4 | Control Connector (Bottom) – Modem ‘B’ (DB-9F)
The Modem ‘B’ Control connector is a 9-pin Type ‘D’ female interface. Pins 2, 3, and 4
carry signals looped through the switch module from Modem ‘A’ to Modem ‘B’, while
pins 6, 7, and 8 loop the same signals from Modem ‘B’ through to Modem ‘A’. The
12VDC input, which is diode OR’ed with the corresponding 12 VDC input from Modem
‘A’, powers the switch module.
Table 3-3. J4 | Control B Modem Connector Pinouts
Pin
Signal Name
Signal Function
Direction
5
GROUND
Signal Ground
---
9
+12VDC
+12VDC
In
4
ONLINE_B
Modem ‘B’ Online
Out
8
SERIAL_FAULT_B
Modem ‘B’ Serial Faults
In
3
CLK_OUT_A
Modem ‘A’ Clk Out
Out
7
CLK_IN_B
Modem ‘B’ Clk In
In
2
AUX_SER_TX_A
Modem ‘A’ Tx Comm
Out
6
AUX_SER_TX_B
Modem ‘B’ Tx Comm
In
1
GROUND
Signal Ground
---
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Switch Connectors and Pinouts
Revision 14
3–6
3.2.2 Antenna Side Connectors
•
See Section 1.3.1 in Chapter 1. INTRODUCTION for information about the LED Indicators.
•
See Section 1.3.1 in Chapter 1. INTRODUCTION and Section 4.10 in Chapter 4. MODEM
AND SWITCH CONFIGURATION for information about the “Switch Conditions” and
“Intelligent / Dumb Controller” DIP switches.
Figure 3-4. CRS-170A – Antenna Side Connectors and Ground Stud (Rev. A and Later
Versions)
3.2.2.1
RF Connectors (50Ω Type ‘N’)
Two 50Ω Type ‘N’ female connectors on the antenna side of the CRS-170A
provide the coaxial cable connections to the outdoor receive and transmit
equipment.
Table 3-4. J7 | Rx and J8 | Tx ‘Type ‘N’ Connectors
Ref Des
Name
Connector Type
Function
J7
Rx
Type ‘N’
RF Input
J8
Tx
Type ‘N’
RF Output
3.2.2.2
Ground Stud
CAUTION: PROPER GROUNDING PROTECTION IS REQUIRED. THE INSTALLATION
INSTRUCTIONS REQUIRE THAT YOU MUST ENSURE THE INTEGRITY OF THE PROTECTIVE
EARTH AND THAT YOU MUST MAINTAIN THE EQUIPMENT’S CONNECTION TO THE
PROTECTIVE EARTH AT ALL TIMES.
Use the #10-32 stud provided on the antenna side of the Switch for connecting a common
chassis ground among equipment.
Chapter 4. MODEM AND SWITCH
CONFIGURATION
4.1
Overview
To avoid damage either to the modem pair or the CRS-170A switch, it is important that
you follow this sequence of configuration:
•
First, configure both modems for 1:1 redundant operation as directed in this chapter. This
chapter organizes the modem-specific sections and any specific interface configuration
examples as follows:
For Product...
See Chapter Section
CDM-625A or CDM-625
4.2
H64, H32, H16, or H8 Heights Remote Gateway
4.3
Advanced VSAT CDM-850 or CDM-840
4.4
CDM-760 or CDM-750
4.5
CDM-570L or CDM-570AL
4.6
CDM-710GL, CDM-710, or CDM-700
4.7
CDM-600L (CLM-9600L)
4.8
SDM-300L3
4.9
•
Then, once you properly configure both modems for 1:1 redundant operation, set the DIP
switches on the CRS-170A to the correct modem selection. See Sect. 4.10 CRS-170A Switch
DIP Settings for details.
•
Finally, once you properly configure both modems and the DIP switches, connect the
control and IF cables between the powered OFF modems and switch. See Chapter 5.
CABLES and CONNECTIONS for details.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–2
BLANK PAGE
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–3
4.2
Configure the CDM-625A or CDM-625 for 1:1 Redundancy
•
CDM-625A Advanced Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM625A)
•
CDM-625 Advanced Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM625)
The CDM-625A or CDM-625 Advanced Satellite Modem automatically detects if it is connected to a 1:1
redundancy system – the steps required to configure both modems are therefore minimal, with some
exceptions:
If the CDM-625A or CDM-625 has the optional IP Packet
Processor installed and enabled, 1:1 Redundancy is
controlled from the CDM-625A or CDM-625 HTTP
Interface Redundancy page.
When both the traffic and backup modems are
equipped with the optional IP Packet Processor and
are connected to the CRS-170A L-Band 1:1
Redundancy Switch), there is no need to use the
drop-down menu here, as Packet Processor
Redundancy is enabled automatically.
If you wish to operate either modem outside of the redundant setup as a standalone unit, use the drop-
down menu to select Packet Processor Redundancy for that specific modem as Disabled.
If terrestrial data is not Ethernet and CnC will not be used, then no modem 1:1 redundancy configuration
is needed. Otherwise, if either applies, refer to the sections that follow.
4.2.1
CDM-625A or CDM-625 Remote User M&C Ethernet Interface
4.2.1.1
For CDM-625A or CDM-625s without the Optional IP Packet
Processor
See the CDM-625A or CDM625 Advanced Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM625A or MN-CDM625) for instructions to configure one of the four
10/100 Ethernet ports as the Dedicated Management Port for remote Ethernet M&C.
TO AVOID ETHERNET NETWORKING LOOPS – If you configure more than one Ethernet port
for Ethernet traffic, you must use separate Layer 2 switches unless the Layer 2 switch in use
isolates these ports from one another.
You may configure one of the CDM-625A or CDM-625’s four available 10/100 Ethernet ports for M&C
Ethernet. As configured in Dedicated Management Port Mode, when the modem is offline the M&C-
designated port remains functional and available for operation, while the three remaining ports are
unavailable. Otherwise, if none of the 10/100 Ethernet ports are reserved for M&C operation; all four
ports become unavailable when the modem is offline.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–4
4.2.1.2
For CDM-625A or CDM-625s Equipped With the Optional IP Packet
Processor
TO AVOID ETHERNET NETWORKING LOOPS – While in 1:1 Redundancy mode, with the optional
IP Packet Processors enabled and both units operating in Managed Switch Mode, the Port 1
M&C Ethernet must be isolated from the Ethernet Traffic. Also, if you use more than one of the
Traffic Ports (Ports 2, 3, or 4), you must use separate Layer 2 switches unless the Layer 2
switch in use isolates these ports from one another.
You may not configure your modem for Dedicated Management Port Mode when the optional IP Packet
Processor is installed and enabled. Under such functionality, in 1:1 redundancy Port 1 is available only
for M&C on both modems, while Ports 2, 3, and 4 are disabled when a modem is in the Offline state.
4.2.2
Configure CDM-625A or CDM-625 Carrier-in-Carrier® for
Redundancy Operation
The Pre-Mapped Symbol Interface (PMSI) is associated with DoubleTalk® Carrier-in-Carrier®. It permits
the modulator in a selected unit to provide a direct copy of its output (the outbound interferer) to the
second modem. The other modem may then choose to take the PMSI signal and use it for its own CnC
reference. In 1:1 redundancy, the PMSI is an EIA-485 multi-drop bus system where one device transmits
and the other device on the multi-drop bus is configured to receive.
If you use Carrier-in-Carrier® (CnC), you must configure the CnC control setting to Redundancy mode
using the CDM-625A or CDM-625 front panel menus.
Do these steps to configure the CnC control setting for CDM-625A or CDM-625 1:1 Redundancy:
Step
Task
1
From the modem front panel menu – Use the ◄► arrow and ENTER keys to select the PMSI control
mode menu:
SELECT: Configuration CnC PMSI-control
CnC PMSI mode: Redundancy
(Idle, Redundancy, Talk, Listen) ()
Use the ▲ ▼ arrow keys to select Redundancy, and then press ENTER.
2
You will now need to connect the two modems together via use of a 1:1 PMSI cable (note that this
cable bypasses the CRS-170A).
• Chapter 5. CABLES AND CONNECTIONS
• Appendix A. CABLE DRAWINGS
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–5
4.3 Heights Remote Gateways in 1:1 Redundancy
Heights Networking Platform Spoke (Remote) Side Products Installation and
Operation Manual
(CEFD P/N MN-HEIGHTS-SPOKE)
The H64, H32, H16, or H8 Heights Remote Gateway automatically detect connection to a 1:1
redundancy system. With both units automatically configured for 1:1 operation, the online unit keeps
the offline unit updated as the online unit configuration changes occur.
If you choose to manually force backup of the online unit, you must execute the switchover by using the
Redundancy section of the online unit HTTP Interface ‘Utility | Utility’ page. Figure 4-1 shows an
example of this page, which is subject to update.
Figure 4-1. Heights Remote Gateway HTTP Interface ‘Utility’ Page Example (Page Banner,
VFP NOT SHOWN)
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–6
See Figure 4–2. If the unit is part of a 1:1 redundant pair and the unit is currently online, click [Force
Redundancy Switch] to force this currently active unit to switch to standby mode.
(TOP) Page Section with Switch ONLINE
(BOTTOM) Page Section with Switch OFFLINE
Figure 4–2. Heights Remote Gateway ‘Utility | Utility’ Page “Redundancy” Section:
Online/Offline Examples
Complete operational considerations for this page section are as follows:
•
Current Redundancy State: This lists redundancy status for this unit as “On Line” or “Off Line”.
Click [Force Redundancy Switch] to place the unit into its alternate state.
•
Offline Unit Mgmt IP: Enter the IP Address in the form xxx.xxx.xxx.xxx. Click [Submit] to save.
•
Offline Unit Status: This item defaults to “0000”
•
Redundancy Detect Latch Set: This item identifies whether the unit was previously detected as
part of a redundancy system. Click [Clear] when the unit transitions to standalone operation.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–7
4.4
Advanced VSAT CDM-850 or CDM-840 Operation in 1:1 Redundancy
•
CDM-850 Remote Router Installation and Operation Manual (CEFD P/N MN-CDM850)
•
CDM-840 Remote Router Installation and Operation Manual (CEFD P/N MN-CDM840)
The Advanced VSAT CDM-850 and CDM-840 Remote Routers automatically detect connection to a 1:1
redundancy system. With both units automatically configured for 1:1 operation, the online unit keeps
the offline unit updated as online unit configuration changes occur.
If you choose to manually force backup of the online unit, you must execute the switchover by using the
Redundancy section of the online unit HTTP Interface ‘Utility | Utility’ page. Figure 4-3 shows an
example of this page, which is subject to update.
Figure 4-3. Advanced VSAT CDM-850 or CDM-840 HTTP Interface ‘Utility | Utility’ Page
Example (Page Banner, VFP NOT SHOWN)
If the unit is part of a 1:1 redundant pair and the unit is currently online, click [Force Redundancy
Switch] to force this currently active unit to switch to standby mode.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–8
Notes:
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–9
4.5
CDM-760 or CDM-750 Operation in 1:1 Redundancy
•
CDM-760 Advanced High-Speed Trunking Modem Installation and Operation Manual
(CEFD P/N MN-CDM760)
•
CDM-750 Advanced High-Speed Trunking Modem Installation and Operation Manual
(CEFD P/N MN-CDM750)
The CDM-760 and CDM-750 Advanced High-Speed Trunking Modems automatically detect connection
to a 1:1 redundancy system.
Typical for either product, with both modems automatically configured for 1:1 operation, the online
modem keeps the offline modem updated as online modem configuration changes occur.
You can also manually ‘force’ backup of the online modem. Use the modem front panel to select the
SELECT: Utility 1:1 screen:
Press ENTER key to force Unit into
Standby (1:1 only)
If this unit is currently the online unit in a 1:1 redundant pair, press ENTER to force the unit to switch to
standby mode.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–10
Notes:
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–11
4.6
Configure the CDM-570Ls or CDM-570ALs for 1:1 Redundancy
•
CDM-570/CDM-570L/CDMR-570L Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM570L.IOM)
•
CDM-570A/CDM-570AL Satellite Modem Installation and Operation Manual (CEFD P/N
MN-CDM570A)
For correct operation of the CRS-170A, the CDM-570/A Satellite Modems must have the
following installed:
•
CDM-570L Base Modem Firmware Version 1.6.7 (or higher)
•
CDM-570L with Optional IP Module Firmware Version 1.5.4.2 (or higher)
•
CDM-570L Hardware Revision 3
•
CDM-570AL Base Modem Firmware Version 1.1.1 (or higher)
•
CDM-570AL with Optional IP Packet Processor Firmware Version 1.2.1 (or higher)
If your modems do not meet this requirement, contact Comtech EF Data Product Support.
You may download free Firmware updates from the Comtech EF Data web site. Hardware
revision upgrades must be performed at Comtech EF Data.
Front Panel
Telnet Command Line Interface (CLI)
Ethernet HTTP Interface
Figure 4-4. CDM-570L or CDM-570AL Configuration Interface Examples
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–12
Because the modem automatically detects if it is connected to a 1:1 redundancy system, the steps
required to configure both modems are minimal. Modem configuration, monitor and control are
possible through local or remote means (Figure 4-4):
•
Local Control – Use the modem front panel to fully configure, monitor, and control the modem
operation:
o The LEDs indicate, in a summary fashion, the status of the modem.
o The VFD (Vacuum fluorescent Display) is an active display showing two lines of 24
characters each. It produces a blue light with adjustable brightness. Nested menus
display all available options and prompt you to carry out a required action.
o The keypad comprises six individual keyswitches. The keys have a positive ‘click’ action
that provides tactile feedback. Enter data via the keypad. Data, prompts, and messages
are displayed on the VFD.
•
Serial Remote Control – Configuration, monitoring and control of redundant systems is possible
via remote means over an RS-485 multi-drop bus using Windows Command-Line, where data is
transmitted in asynchronous serial form using ASCII characters.
•
Ethernet Remote Control – Configuration, monitoring and control of redundant systems is
possible via remote means over an Ethernet connection using the Telnet Command Line
Interface (CLI) or the CDM-570L/A HTTP Interface.
4.6.1
CDM-570L or CDM-570AL Non-IP Redundancy Configuration
Do these steps for setup of CDM-570L or CDM-570AL modems for 1:1 Redundancy, when the terrestrial
data type is non-Ethernet (i.e. RS422, G.703).
Step
Task
1
Enable 1:1 Redundancy on both modems:
• From the CLI Main Menu, press ‘E’ to open the 1:1 Redundancy Configuration page.
o
Press ‘R’ to toggle 1:1 Redundancy as [Enabled].
o
Press ‘S’ to ““Save Parameters to permanent storage”.
• Alternately, using the HTTP Interface ‘REDUNDANCY’ page:
o
Use the drop-down list in the 1:1 Redundancy Control section of this page to select Enabled.
o
Click [Submit] to save.
If you submit any changes to this web page when the CDM-570AL optional IP Packet
Processor is INSTALLED, you must also open the ‘Admin | Pap Save’ page and
immediately click [Save PaP Parameters].
2
Connect all cables to the modems and the CRS-170A. This includes the control cable, IF cable and data
‘Y’cables.
Chapter 5. CABLES AND CONNECTIONS
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–13
4.6.2
IP Redundancy Configuration
Before continuing you must remember that, when you use the Command Line Interface
(CLI), you can make configuration changes to the Online modem only. Make sure to press ‘S’
to “Save Parameters to permanent storage” after making any changes to an active CLI page.
This ensures that the configuration change is also applied to the Backup modem.
Do these steps for setup of a CDM-570L or CDM-570AL 1:1 IP Redundancy System:
Step
Task
1
Use a Layer 2 switch (preferred) or hub to establish an Ethernet connection between the two modems.
2
Before you connect the modems to the CRS-170A, you must first use the modem CLI to configure the
following CDM-570L or CDM-570AL IP operation settings:
• Disable 1:1 Redundancy operation – From the Main Menu, press ‘E’ to open the 1:1 Redundancy
Configuration page.
o
Press ‘R’ to toggle 1:1 Redundancy as [Disabled].
• From the Main Menu, press ‘A’ to open the Administration page.
o
Press ‘W’ (Administration Working Mode) and set both modems to the same Working
Mode.
o
Press ‘F’ (Administration Feature Configuration) and make sure to configure, using all
applicable submenus, both modems to have the same IP-related operability and settings.
3
For each modem, use the CLI to enter a unique IP Address that is on the same subnet:
• From the Main Menu, press ‘I’ to open the Interface Configuration page.
• Press ‘E’ to open the Ethernet Interface page (Interface Configuration Ethernet Interface):
• Press ‘I’ to enter the IP Address.
4
Verify that you can ping from one modem to the other:
• From the Main Menu, press ‘O’ to open the Operations and Maintenance page.
• Press ‘G’ to open the Diagnostics page (Operations and Maintenance Diagnostics):
• Press ‘P’ and then enter the IP Address of the other modem in the redundant pair.
5
Re-enable 1:1 Redundancy operation – From the Main Menu, press ‘E’ to open the 1:1 Redundancy
Configuration page.
• Press ‘R’ to toggle 1:1 Redundancy as [Enabled].
6
Power down both modems.
7
Connect the modems to the CRS-170A.
CDM-570/CDM-570L/CDMR-570L Satellite Modem Installation and Operation
Manual (CEFD P/N MN/CDM570L.IOM): Sect. H.6 Cabling with the CDM-570L.
8
Power on both modems at the same time. Observe the CRS-170A Online LEDs to see which modem is
the Online modem. Monitor the CLIs for both modems to confirm the following:
Online modem CLI displays:
1:1 Redundancy (Auto Detected)
Redundancy: PARAM File Connection Established.
Redundancy: Sending PARAM File...
Offline modem CLI displays:
1:1 Redundancy (Auto Detected)
Redundancy: Received PARAM File...
Writing 5447 bytes to PARAM file on Flash
9
On the Online modem, view the CLI 1:1 Redundancy Configuration page (Figure 4-5) to confirm that the
correct Management IP Addresses and Prefix Lengths display for the Local and Redundant Units.
Then, press ‘T’ to set the Traffic IP Address, and ‘M’ to set the Traffic Subnet Prefix Length (these also
need to be in the same subnet as the Management IP addresses).
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–14
Figure 4-5. CDM-570L or CDM-570AL CLI 1:1 Redundancy Configuration Screen
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–15
4.7
Configure the CDM-710GLs, CDM-710s, or CDM-700s for 1:1
Redundancy
•
CDM-710G/710GL Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM710G)
•
CDM-710 Broadcast Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM710.IOM)
•
CDM-700 Satellite Modem Installation and Operation Manual
(CEFD P/N MN/CDM700.IOM)
For correct operation of the CRS-170A, the CDM-710GL, -710, and -700 modems must have
the following installed:
•
For the CDM-710GL:
o Firmware Version 5.1.1 (or higher)
•
For the CDM-710:
o Firmware Version 2.4.1 (or higher)
o Hardware Revision A (chassis with round-buttoned keypad)
•
For the CDM-700:
o Firmware Version 1.1.6 (or higher)
o Hardware Revision A (chassis with round-buttoned keypad)
Note that Hardware upgrades are possible only for the CDM-710 or CDM-700 Rev. A version
chassis and later – 1:1 redundancy operation is not available with hardware versions prior to
Rev. A.
If your modems do not meet these requirements, contact Comtech EF Data Product
Support. You may download free Firmware updates from the Comtech EF Data web site.
Hardware revision upgrades must be performed at Comtech EF Data.
Modem configuration, monitor and control are possible through local or remote means:
•
Local Control – Use the modem front panel to fully configure, monitor, and control the modem
operation:
o The LEDs indicate, in a summary fashion, the status of the modem.
o The VFD (Vacuum fluorescent Display) is an active display showing two lines of 24
characters each. It produces a blue light with adjustable brightness. Nested menus
display all available options and prompt you to carry out a required action.
o The keypad comprises six individual keyswitches. The keys have a positive ‘click’ action
that provides tactile feedback. Enter data via the keypad. Data, prompts, and messages
are displayed on the VFD.
•
Serial Remote Control – Configuration, monitoring and control of redundant systems is possible
via remote means over an RS-485 multi-drop bus using Windows Command-Line, where data is
transmitted in asynchronous serial form using ASCII characters.
•
Ethernet Remote Control – Configuration, monitoring and control of redundant systems is
possible via remote means over an Ethernet connection using the CDM-7XX HTTP Interface.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–16
4.7.1
Non-IP Redundancy Configuration
Do these steps for setup of the CDM-710GL, -710, or -700 modems for 1:1 Redundancy when the
terrestrial data type is non-Ethernet (e.g., ASI, HSSI, G.703):
Step
Task
1
Enable the redundancy state for both modems. From the modem front panel:
CONFIG: AUX (Redundancy Mode) ENA/DIS – set to Enable.
2
Connect all cables – including the control cable, IF cable and data cables – to the modems and the CRS-170A.
Chapter 5. CABLES AND CONNECTIONS
4.7.2
IP Redundancy Configuration
Do these steps for setup of the CDM-710GL, -710, or -700 modems for 1:1 IP Redundancy (i.e., when
the terrestrial data type is Gigabit Ethernet (GigE or GbE)):
Step
Task
1
Before connecting the modems to the CRS-170A, you must first configure the following IP module settings on
each modem. From the modem front panel:
CONFIG: AUX (Redundancy Mode) ENA/DIS set to Disable.
2
Enable the redundancy state for both modems. From the modem front panel:
CONFIG: AUX (Redundancy Mode) ENA/DIS set to Enable.
Press ENTER to save your settings.
3
Connect all cables – including the control cable, IF cable and data cables – to the modems and the CRS-
170A. Additionally, you must use a Layer 2 switch to establish an Ethernet connection between each modem.
Chapter 5. CABLES AND CONNECTIONS
4
Verify that the ONLINE LEDs for the CRS-170A indicate the same online state as displayed by the modems’
front panel LEDs.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–17
4.8
CDM-600L (CLM-9600L) Operation in 1:1 Redundancy
• CLM-9600L Open Network Satellite Modem Installation and Operation Manual (CEFD P/N
MN/CLM9600L.IOM)
• CRS-150 1:1 Redundancy Switch Installation and Operation Manual
(CEFD P/N MN/CRS150.IOM)
1) Correct operation of the CRS-170A requires use of the CRS-150 1:1 Redundancy Switch.
2) While the CDM-600L (CLM-9600L) Open Network Satellite Modems require no unique
1:1 configuration settings, they must have the following installed:
•
Firmware Version 1.1.4 (or higher)
•
Hardware Revision 3
If the modems do not meet this requirement, contact Comtech EF Data Product
Support. Firmware updates are free and may be downloaded from the Comtech EF Data
web site. (www.comtechefdata.com). Hardware revision upgrades must be performed
at CEFD.
4.9
SDM-300L3 Operation in 1:1 Redundancy
• SDM-300L3 Satellite Modem Installation and Operation Manual
(CEFD P/N MN/SDM300L3.IOM)
• SMS-301 Redundancy Switch Installation and Operation Manual
(CEFD P/N MN/SMS301.IOM)
1) Correct operation of the CRS-170A requires use of the SMS-301 Redundancy Switch.
2) While the SDM-300L3 Satellite Modems need no unique 1:1 configuration settings, they
must have the following installed:
•
Firmware Version 1.1.4 (or higher)
•
Hardware Revision 3
If the modems do not meet this requirement, contact Comtech EF Data Product
Support. Firmware updates are free and may be downloaded from the Comtech EF
Data web site. (www.comtechefdata.com). Hardware revision upgrades must be
performed at CEFD.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–18
Notes:
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–19
4.10 CRS-170A DIP Switch Settings
The ‘Switch Conditions’ DIP switches are set depending upon the type of Tx or Rx traffic
conditions resultant of switchover. Some modems have additional settings or alarm
masks that affect conditions – see your individual modem manual for detailed
explanations.
Comtech EF Data’s expansion of compatible product required a change in the labeling on the Antenna
Side (towards the BUC and LNB) of the CRS-170A L-Band 1:1 Redundancy Switch. Figure 4-6 shows the
change to the ‘Mode’ DIP switch labeling between the original and current (i.e., Rev. ‘A’ and later)
production versions of the CRS-170A.
Use these features to set the ‘Mode’ and ‘Switch Conditions’ controls:
•
See Table 4-1 for setting the ‘Mode’ DIP switches. These settings define product/switch
compatibility.
•
See Table 4-2 for setting the ‘Switch Conditions’ DIP switches. These settings define the
conditional switchover functions.
Switch Version
Item
Description
Function
A – Original Chassis Design
B – Rev ‘A’ and LATER Design
1
“Mode Settings” DIP
Switches
Product Compatibility
Selection
2
“Switch Conditions” DIP
Switches
Switchover Functionality
Figure 4-6. CRS-170A Antenna Side Controls
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Modem and Switch Configuration
Revision 14
4–20
Table 4-1. CRS-170A “Mode” DIP Switches – Product Compatibility Settings
Product
DIP Switch
Setup
Left Switch
Right Switch
CDM-625A or CDM-625
Up
Down
Heights Networking Platform
H64/H32/H16/H8 Heights Remote Gateway
Advanced VSAT CDM-850 or CDM-840
CDM-760 (L-Band)
CDM-750 (L-Band)
Up
Down
CDM-570L
CDM-570AL
Up
Down
CDM-710GL
Up
Down
CDM-710 (L-Band)
Up
Down
CDM-700 (L-Band)
Up
Down
CDM-600L (CLM-9600L)
Down
Up
SDM-300L3
Down
Down
Table 4-2. CRS-170A “Switch Control” DIP Switches – Functional Settings
DIP
Left Switch
Right Switch
Functional Result
Down (Off)
Down
Switchover upon a Unit fault
Up
Down
Switchover upon a Unit or Tx Traffic fault
Down
Up
Switchover upon a Unit or Rx Traffic fault
Up
Up
Switchover upon a Unit or Tx Traffic or Rx
Traffic fault
Chapter 5. CABLES AND
CONNECTIONS
5.1
Overview
When assembling a Comtech EF Data 1:1 Redundancy System, in addition to purchasing the modem pair
(one Redundant Modem, one Traffic Modem), you must also purchase a redundancy kit tailored to that
modem choice. Each kit provides the CRS-170A L-Band 1:1 Redundancy Switch module, plus all cables
and components required for interconnection of the redundant configuration to various interfaces (i.e.,
control, IF, and data). This excludes Ethernet operation, which requires user-provided cabling and Layer
2 switching.
1) The cables required between each modem and Switch should be of shielded, twisted-
pair construction, with the grounded shield bonded to the back shell. All data cables
should be wired correctly using the pinout and connection information as specified in
Appendix A. CABLE DRAWINGS.
2) It is physically impossible to connect all available data interface solutions within a single
1:1 redundancy system at a given time. For example, when using the CDM-625A or
CDM-625 in a 1:1 system, you are unable to establish an ASI interface together with a
G.703 Unbalanced interface, or an EIA-422/232 interface together with an HSSI
interface. The quantities of cables and accessories supplied with each redundancy kit
take such operational limitation into consideration.
3) The type of 1:1 Y-Splitter cable required for modem-to-user interconnection depends on
your data interface. It is essential to ensure that the control and IF connections, both Rx
and Tx, are made correctly.
4) The Electronic Industries Association (EIA) designations supersede the Recommended
Standard (RS) designations. References to the old designations may be shown when
depicting actual text (e.g., RS-232) displayed on Switch or the individual modem Web
Server pages, serial remote interfaces, Telnet Command Line Interfaces (CLIs), or unit
rear panels. All other references in the manual refer to EIA designations.
5) The modem-specific sections in this chapter identify the required redundancy kit:
•
Section 5.2 Common CRS-170A 1:1 Redundancy Control / IF Interface Cabling Kits
•
Section 5.3 Cabling the CDM-625A or CDM-625
•
Section 5.4 Cabling the Heights Remote Gateway
•
Section 5.5 Cabling the Advanced VSAT CDM-850
•
Section 5.6 Cabling the Advanced VSAT CDM-840
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–2
•
Section 5.7 Cabling the CDM-760 or CDM-750
•
Section 5.8 Cabling the CDM-570AL or CDM-570L
•
Section 5.9 Cabling the CDM-710GL
•
Section 5.10 Cabling the CDM-710
•
Section 5.11 Cabling the CDM-700
•
Section 5.12 Cabling the CDM-600L (CLM-9600L)
•
Section 5.13 Cabling the SDM-300L3
6) Separately sold interface kits and cable assemblies are available to enable connection
from the modems to a variety of user terrestrial data interfaces. Examples of these cabling
configurations are further identified throughout this chapter.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–3
5.2
Common CRS-170A 1:1 Redundancy Control / IF Interface Cabling
Kits
When assembling a Comtech EF Data 1:1 Redundancy System, in addition to purchasing the desired
modem pair (one Traffic Modem, one Backup Modem), you must also purchase a CRS-170A 1:1
Redundancy Control/IF Interface Cabling Kit tailored to your modem choice. Each kit provides the
CRS-170A L-Band 1:1 Redundancy Switch module and the control and IF cables required for connection
of the switch to the modems in the 1:1 redundancy configuration.
Kit usage, on a per-modem basis, is as follows:
CRS-170A 1:1
Redundancy Control / IF
Interface Cabling Kit
Modem Pair
Control
Connections
Figure
IF Connections
Figure(s)
KT-0000160
CDM-625A or CDM-625
5-1
5-2, 5-3
H64, H32, H16, or H8 Heights Remote Gateway
5-18
5-19
Advanced VSAT CDM-850
5-23
5-24
Advanced VSAT CDM-840
5-28
5-29
CDM-760 or CDM-750
5-32
5-33
KT/12551
CDM-710GL
5-45
5-46
CDM-710
5-51
5-52
CDM-700
5-57
5-58
1) Note these requirements:
•
The CDM-570L and CDM-570AL require a modem-specific redundancy kit, CEFD
P/N KT/10860-1. See Section 5.8.1 for details.
•
Cabling requirements for the CDM-600L (CLM-9600) Open Network Satellite
Modems are shown in Figure 5-64 in Section 5.12.
•
Cabling requirements for the SDM-300L3 Satellite Modems are shown in See
Figure 5-65 in Section 5.13.
2) Excluding Ethernet (which require user-supplied CAT5 Ethernet cables and Layer 2
switches), separately sold kits are available from Comtech EF Data to connect your
modems to a variety of terrestrial data interfaces. See the “Modem-to-User Data
Interface Connections and Examples” sections for each modem in this chapter for
examples of these kits.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–4
5.2.1
KT-0000160 Redundancy Control / IF Interface Cabling Kit
(CDM-625A or CDM-625, Heights or Advanced VSAT Products, CDM-
760 or CDM-750)
KT-0000160 1:1 Redundancy Control / IF Interface Cabling Kit
CEFD Part No.
Qty
Description
Used For
PL/10129-1
1
CRS-170A Switch – Top Assembly
1:1 Redundancy
CA/WR9378-4*
2
Control Cable – Universal, DB-9M DB-9M, 4’
Modem Switch Control
CA/RF10453-4
4
RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type ‘N’, 4’ Modem Switch IF
Interface
* Alternate Cabling Note: CEFD Universal Control Cable CA/WR9378-8 (DB-9M DB-9M, 8’),
sold separately, is available for use in place of CA/WR9378-4
5.2.2
KT/12551 Redundancy Control / IF Interface Cabling Kit
(CDM-710GL, CDM-710, CDM-700)
KT/12551 1:1 Redundancy Control / IF Interface Cabling Kit
CEFD Part No.
Qty
Description
Used For
PL/10129-1
1
CRS-170A Switch – Top Assembly
1:1 Redundancy
CA/WR12135-1*
2
Control Cable – Universal, DB-9M DB-9M, 4’
CDM-710GL Switch
Control
CA/RF10453-4
4
RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type ‘N’, 4’ CDM-710GL Switch IF
Interface
* Alternate Cabling Notes:
1) To provide User access to modem “Fault Summary Relay,” Control ‘Y’ Cable
CA/WR13011-4 (DB-15F DB-9M [4’], DB-9M [6”]), sold separately, is available for use
in place of the CA/WR12135-1 cable.
2) Control Cable CA/WR12135-1 will mute the Offline modem’s Tx IF. If this is not desired,
then an alternate cable, Control Cable CA-0000187 (DB-15F DB-9M, 6’), sold
separately, is available for use in place of the CA/WR12135-1 cable
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–5
5.3
Cabling to the CDM-625A or CDM-625
1) For information on the CDM-625A or CDM-625’s 1:1 auto-enable functionality, see:
• Chapter 4. MODEM AND SWITCH CONFIGURATION
• CDM-625A Advanced Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM625A)
• CDM-625 Advanced Satellite Modem Installation and Operation Manual
(CEFD P/N MN-CDM625)
2) For information on the cables and cable assemblies specified in this section, see
Appendix A. CABLE DRAWINGS.
5.3.1
CRS-170ACDM-625A or CDM-625 Control and IF Interface
Connections Using Cabling Kit KT-0000160
You must order terrestrial data interface components/kits separately. See Section
5.3.2 for CDM-625A or CDM-625 terrestrial data interface configuration and
connection examples and details.
You must use Comtech EF Data’s KT-0000160 1:1 Redundancy Control/IF Interface Cabling Kit (Section
5.2.1) for your control and L-Band Modem-to-Switch cabling connections. Figure 5-1, Figure 5-2, and
Figure 5-3 show how to connect a pair of CDM-625A or CDM-625 modems together with the CRS-170A
L-Band 1:1 Redundancy Switch module. The table included with each figure lists the items you will need
from this kit for your initial setup.
IMPORTANT: It is ESSENTIAL that you correctly make your control and the IF Rx and Tx
connections. See Section 5.3.1.1 for details about the CDM-625A or CDM-625 Modem-to-
Switch Control Interface connection, and Section 5.3.1.2 for details about the CDM-625A or
CDM-625 Modem-to-Switch IF Interface connections.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–6
5.3.1.1
Modem-to-Switch Control Interface Connection
1) Excluding modems, the KT-0000160 CRS-170A L-Band 1:1 Redundancy Kit (Section 5.2.1)
provides all components shown in Figure 5-1.
2) When you connect the Control Interface cables between the CRS-170A and the modems,
make sure that you securely fasten the screw locks on the Type ‘D’ connectors. This
prevents accidental disconnection of the cables, particularly when you are removing and
replacing a standby unit.
CEFD Part No.
Qty
Description
CA/WR9378-4
2
Control Cable – Universal, DB-9M, 4’
Figure 5-1. CDM-625A or CDM-625 Modem-to-Switch Control Connections
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–7
5.3.1.2
Modem-to-Switch IF Interface Connection
Excluding modems, the KT-0000160 CRS-170A L-Band 1:1 Redundancy Kit (Section 5.2.1)
provides all components shown in Figure 5-2.
IMPORTANT: The Tx IF from ‘MODEM A’ connects to the Tx IF port ‘J5 | Tx A’ on the
CRS-170A; similarly, the Tx IF from ‘MODEM B’ connects to the Tx IF port ‘J6 | Tx B’ on the
CRS-170A. The same logic applies for the Rx IF connections. It is important to note that
failure to observe this requirement will result in system malfunction.
5.3.1.2.1
Modem-to-Switch L-Band (Rx/Tx) IF Interface Connection
CEFD Part No.
Qty
Description
CA/RF10453-4
4
RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type ‘N’, 4’
Figure 5-2. CDM-625A or CDM-625 Modem-to-Switch L-Band IF Connections
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–8
5.3.1.2.2
Modem-to-Switch L-Band Tx / 70/140 MHz Rx IF Interface
Connection
If the Tx IF is L-Band and the Rx IF is 70/140MHz, additional items may be purchased for
this option, as shown here in Figure 5-3.
Item
CEFD Part No.
Qty
Description
1
CA/RF10453-4
2
RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type ‘N’, 4’
2
CA/BNC75OHM
2
Cable – IF Type ‘BNC’, 1’
3
RF/SA32KC-IN/OUT
1
Combiner – 2-way w/bracket, 0.25-300 MHz, 75Ω BNC
Figure 5-3. CDM-625A or CDM-625 Modem-to-Switch L-Band Tx / 70/140 MHz Rx IF
Connections
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–9
5.3.2
Modem-to-User Data Interface Connections and Examples
5.3.2.1
Modem-to-User Non-IP Data Interface Connections and Examples
The data cables and components identified in each of the examples that follow in this
section must be purchased separately, as required.
In addition to the control and IF Modem-to-Switch cabling shown previously, a number of data interface
configurations are available for the CDM-625A and CDM-625 Advanced Satellite Modems. The Figure
5-4 block diagram is typical for the examples shown in Sections 5.3.2.1.1 through 5.3.2.1.8.
With the exception of the IP (10/100 Ethernet) Interface configurations shown in Section 5.3.2.3 (which
use customer-supplied Ethernet cables and Layer 2 switches), you must use one cabling and component
kit per 1:1 modem pair for each user interface (see examples for specific quantities).
Figure 5-4. CDM-625A or CDM-625 Block Diagram –
UserModemSwitchTraffic
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–10
5.3.2.1.1
EIA-422/232 Interface Example
CEFD Part No.
Qty
Description
CA/RB10461-1
1
Cable – 1:1 ‘Y’ Splitter, (2X) DB-25MDB-25F
Figure 5-5. CDM-625A or CDM-625 EIA-422/232 1:1 Example
5.3.2.1.2
HSSI Interface Example
CEFD Part No.
Qty
Description
CA/RB10461-1
1
Cable – 1:1 ‘Y’ Splitter, (2X) DB-25MDB-25F
PL-0000307
1
CIC-60 – Interconnect Converter, DB-25MHD-50F (SCSI-II)
Figure 5-6. CDM-625A or CDM-625 HSSI 1:1 Example
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–11
5.3.2.1.3
Quad E1 Interface Example
Use the individual G.703 Balanced and Auxiliary G.703 DB-9F connectors for Quad E1 operation.
1) As shown in Figure 5-7, the CA-0000071 ‘Y’ Cable provides for two ports of E1 (i.e., Ports
1/2 -or- Ports 3/4).
2) If you desires three or four separate ports of E1 (i.e., Port 1 and Port 2 -or- Port 3 and
Port 4), then optional adapter cables may be purchased from Comtech EF Data to adapt
the G.703 Balanced and Auxiliary G.703 DB-9F single connector pairs to outgoing Quad E1
connector pairs as follows:
Cable
CEFD P/N
Converts (1) 9-pin Type ‘D’ (DB-9F) paired connection (e.g.,
Modem A AND Modem B G.703 Balanced connector pair –or–
Modem A AND Modem B Auxiliary G.703 connector pair) to:
See
App. A
Fig.
CA-0000163
(2) 15-pin Type ‘D’ (DB-15F) connectors
A-11
CA-0000164
(2) RJ-48 female connectors
A-12
KT-0000122
(4) BNC 75Ω female connectors – (2) Tx, (2) Rx
A-13
All three cabling options plug into the single ‘To User’ connector side of each
CA-0000071 ‘Y’ Splitter cable used.
Figure 5-7. CDM-625A or CDM-625 Quad E1 1:1 Example
CEFD Part No.
Qty
Description
CA-0000071
2 Note 1
Cable – 1:1 ‘Y’ Splitter, (2X) DB-9M DB-9F, 8”
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–12
5.3.2.1.4
G.703 Balanced Interface Example
CEFD Part No.
Qty
Description
CA-0000071
1
Cable – 1:1 ‘Y’ Splitter, (2X) DB-9MDB-9F, 8”
Figure 5-8. CDM-625A or CDM-625 G.703 Balanced 1:1 Example
5.3.2.1.5
G.703 Unbalanced Interface Example
KT/10553-1 G.703 Unbalanced Interface Kit
CEFD Part No.
Qty
Description
CA/BNC75OHM
4
Cable – IF BNC, 1’
CN/BNC-TEE-JPJ
2
T-Adapter, 50Ω BNC
Figure 5-9. CDM-625A or CDM-625 G.703 Unbalanced 1:1 Example
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–13
5.3.2.1.6
ASI Interface Example
KT/12579 ASI 75Ω Interface Kit
CEFD Part No.
Qty
Description
CA/BNC75OHM
4
Cable – IF BNC, 75Ω, 1’
RF/SA32KC-IN/OUT
2
Combiner – 2-way w/Bracket, 0.25-300 MHz, 75Ω BNC
Figure 5-10. CDM-625A or CDM-625 ASI 1:1 Example
5.3.2.1.7
Overhead Interface Example
CEFD Part No.
Qty
Description
CA-0000070
1
Cable – 1:1 ‘Y’ Splitter, (2X) HD-44MHD-44F, 8”
Figure 5-11. CDM-625A or CDM-625 Overhead 1:1 Example
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–14
5.3.2.1.8
Engineering Service Channel (ESC) Interface Example
CEFD Part No.
Qty
Description
CA-0000071
1
Cable – 1:1 ‘Y’ Splitter, (2X) DB-9MDB-9F, 8”
Figure 5-12. CDM-625A or CDM-625 ESC 1:1 Example
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–15
5.3.2.2
Modem-to-User IP (10/100 Ethernet) Interface Examples
5.3.2.2.1
Data Interface Connections Using IP Sub-Mux
•
Appendix N. IP SUB-MUX in CDM-625A Advanced Satellite Modem Installation and
Operation Manual (CEFD P/N MN-CDM625A)
•
Chapter 15. IP SUB-MUX in CDM-625 Advanced Satellite Modem Installation and
Operation Manual (CEFD P/N MN-CDM625)
Subsystem Multiplex – referred to by CEFD as Sub-Mux – is a secondary framing structure that
combines one to four ports of IP (10/100 Ethernet) traffic (see
) with any currently available combination of framing and interface type (see Figure 5-5 through Figure
5-12) – excluding IP itself. The composite data rate to the modulator and from the demodulator is
referenced to the primary, non-IP data interface rate by a specific user-selected ratio.
5.3.2.2.2
Managed Switch Mode (with/without the Optional IP Packet
Processor)
shows the block diagram for the CDM-625A or CDM-625 1:1 modem configuration using the IP (10/100
Ethernet) Interface in Managed Switch Mode (also called Ethernet Bridge Mode). Figure 5-14 shows the
cabling example for this setup.
This configuration requires no cabling kit – you must use user-provided Ethernet cables and Layer 2
switches for direct connection to the modem via one to four RJ-45 ports. This cabling example shows
use of all four Ethernet ports.
1) When in Managed Switch Mode with the Packet Processor either not installed or
installed but disabled, all Ethernet ports on the Offline modem will be disabled. The
exception is if one of the ports has been set to be the Dedicated Management Port. See
the CDM-625A or CDM-625 Advanced Satellite Modem Installation and Operation
Manual (CEFD P/N MN-CDM625A or MN-CDM625) for instructions on configuring one
of the four 10/100 Ethernet ports as the Dedicated Management Port for remote
Ethernet M&C (Dedicated Management Port is available only without the optional
IP Packet Processor).
2) When in Managed Switch Mode with the optional IP Packet Processor installed and
enabled, only Port 1 of the Offline modem is enabled, while Ports 2, 3, and 4 on the
Offline modem are disabled.
3) TO AVOID ETHERNET NETWORKING LOOPS – When in Managed Switch Mode and
using more than one Ethernet port, the ports must not be connected to the same
Layer 2 Switch unless they are isolated from one another. The ports can be isolated by
connecting each port to a separate Layer 2 Switch (see ), or by
configuring separate VLAN’s for each port on a single Layer 2 Switch.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–16
Figure 5-13. CDM-625A or CDM-625 Block Diagram – 10/100 Ethernet 1:1 Managed Switch
Mode
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–17
Figure 5-14. CDM-625A or CDM-625 10/100 Ethernet 1:1 Cabling Example – Managed
Switch Mode (with/without Dedicated Management Port)
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–18
5.3.2.2.3
Router Mode (Requires Optional IP Packet Processor)
•
When the optional IP Packet Processor is installed and enabled, you should use Port 1 of
each modem for M&C purposes only. Reserve use of Port 2, 3, or 4 for each modem for
Ethernet traffic only.
•
TO AVOID ETHERNET NETWORKING LOOPS – Make sure to connect Port 1 (M&C) and the
designated Traffic Port to separate Layer 2 Switches, unless your Layer 2 Switch is
configured to isolate these ports by using VLANs.
Figure 5-15 shows the block diagram for a CDM-625A or CDM-625 1:1 modem configuration using the IP
(10/100 Ethernet) Interface in Router Mode, with the optional IP Packet Processor installed and
enabled. The Figure 5-16 cabling example shows Ethernet Port 2 as the designated Ethernet traffic
connection.
This configuration requires no cabling kit – you must use user-provided Ethernet cables and Layer 2
switch(es) for direct connection to the modem.
Figure 5-15. CDM-625A or CDM-625 10/100 Ethernet 1:1 Example – Router Mode Block
Diagram
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–19
Figure 5-16. CDM-625A or CDM-625 10/100 Ethernet 1:1 Cabling Example – Router Mode
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–20
5.3.2.3
PMSI Interface Example
The Pre-Mapped Symbol Interface (PMSI) is an EIA-485 point-to-point bus system where one device
transmits, and the other device on the bus is configured to receive. It is a function associated with
DoubleTalk® Carrier-in-Carrier® (CnC®) that permits the modulator in a selected unit to provide a direct
copy of its output (the outbound interferer) to the Offline modem in a 1:1 pair. The Offline modem then
takes the PMSI signal and uses it for its own CnC® reference.
You must take specific configuration steps to enable CnC® in your CDM-625A or CDM-625 1:1 pair before
you can make any switch configurations, This ensures proper operation of the pair within a configured
CRS-170A 1:1 Redundancy System.
Chapter 4. MODEM AND SWITCH CONFIGURATION
Use of PMSI requires that you connect and secure the CDM-625A or CDM-625 Multi-drop CnC® Plus 1:1
Cable CA-0000276 (2X DB-9M, 1’) between the Redundant Modem and the Traffic Modem using CnC.
See Figure 5-17.
The CA-0000276 Multi-Drop CnC PLUS 1:1 Cable bypasses the CRS-170A L-Band 1:1
Redundancy Switch.
CEFD Part No.
Qty
Description
CA-0000276
1
CDM-625A or CDM-625 Data Cable – Shielded, Multi-drop CnC® Plus, 1:1, (2X)
DB-9M, 1’
Figure 5-17. CDM-625A or CDM-625 PMSI 1:1 Example
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–21
5.4
Cabling to the Heights Remote Gateway (HRG)
1) For information on the H64, H32, H16, or H8 Heights Remote Gateway (HRG) 1:1 auto-
enable functionality, see:
• Chapter 4. MODEM AND SWITCH CONFIGURATION
• Heights Networking Platform Spoke (Remote) Site Products Installation and
Operation Manual
(CEFD Part No. MN-HEIGHTS-SPOKE)
2) For information on the cables and cable assemblies specified in this section, see
Appendix A. CABLE DRAWINGS.
3) The figures provided in this section show the H64 Heights Remote Gateway as the
example unit. You must make note of the cabling differences, where applicable, for your
specifically deployed Heights product: The H64 or H32 (common chass, bottom), H16
(center), or H8 (top).
5.4.1
CRS-170A HRG Control and IF Interface Connections Using
Cabling Kit KT-0000160
The HRG employs 10/100/1000 Ethernet (Gigabit Ethernet, also identified throughout this
chapter as GigE or GbE) as its sole terrestrial data interface. All cables and switches are
provided by the user. See Section 5.4.2 for the HRG Gig
abit Ethernet terrestrial data interface configuration and connection examples and details.
You must use Comtech EF Data’s KT-0000160 1:1 Redundancy Control/IF Interface Cabling Kit (Section
5.2.1) for your control and L-Band Unit-to-Switch cabling connections. Figure 5-18 and Figure 5-19 show
how to connect a pair of HRGs together with the CRS-170A L-Band 1:1 Redundancy Switch module. The
table included with each figure lists the items you will need from this kit for your initial setup.
IMPORTANT: It is ESSENTIAL that you make the Control and the IF Rx and Tx connections
correctly. See Section 5.4.1.1 for details about the HRG Unit-to-Switch Control Interface
connection, and Section 5.4.1.2 for details about the HRG Unit-to-Switch IF Interface
connections.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–22
5.4.1.1
Unit-to-Switch Control Interface Connection
1) The KT-0000160 CRS-170A L-Band 1:1 Redundancy Kit (Section 5.2.1) provides all
components shown in Figure 5-18.
2) When you connect the Control Interface cables between the CRS-170A and the HRGs,
make sure that you securely fasten the screw locks on the Type ‘D’ connectors. This
prevents accidental disconnection of the cables, particularly when you are removing and
replacing a standby unit.
CEFD Part No.
Qty
Description
CA/WR9378-4
2
Control Cable – Universal, DB-9M, 4’
Figure 5-18. HRG Unit-to-Switch Control Connections
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–23
5.4.1.2
Unit-to-Switch IF Interface Connection
The KT-0000160 CRS-170A L-Band 1:1 Redundancy Kit (Section 5.2.1) provides all
components shown in Figure 5-19.
IMPORTANT: The Tx IF from ‘Unit A’ connects to the Tx IF port ‘J5 | Tx A’ on the CRS-170A;
similarly, the Tx IF from ‘Unit B’ connects to the Tx IF port ‘J6 | Tx B’ on the CRS-170A. The
same logic applies for the Rx IF connections. It is important to note that failure to observe
this requirement will result in system malfunction.
CEFD Part No.
Qty
Description
CA/RF10453-4
4
RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type ‘N’, 4’
Figure 5-19. HRG Unit-to-Switch L-Band IF Connections (H64 Shown)
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–24
5.4.2
Unit-to-User Data Interface Connections and Examples
In addition to the control and IF Unit-to-Switch cabling shown previously, the HRG features an eight-port
10/100/1000 Gigabit Ethernet data interface.
5.4.2.1
HRG Managed Switch Mode (Ethernet Bridge Mode)
Figure 5-20 shows the block diagram for a HRG 1:1 redundant configuration in Managed Switch Mode
(also called Ethernet Bridge Mode). Figure 5-21 shows the cabling example for this setup. This
configuration requires no cabling kit – you must use user-provided Ethernet cables and Layer 2 switches
for direct connection to the modem via (dependent on the installed product) two, four, or eight RJ-45
Traffic Ethernet ports.
As applicable to the H64 or H32 HRG, both figures depict use of all eight available RJ-45
Traffic Ethernet ports.
Figure 5-20. HRG Block Diagram – Gigabit Ethernet 1:1 Managed Switch Mode
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–25
Figure 5-21. HRG Gigabit Ethernet 1:1 Cabling Example (H64 Shown) – Managed Switch
Mode
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–26
5.4.2.2
HRG Router Mode
Figure 5-22 shows the block diagram and cabling example for an HRG 1:1 redundant configuration using
the Gigabit Ethernet Interface in Router Mode. This configuration requires no cabling kit – you must use
user-provided Ethernet cables and Layer 2 switch for direct connection to the modem via any one of the
two, four, or eight available RJ-45 Traffic Ethernet ports.
Both details in Figure 5-22 show use of ‘GE1’ Traffic Ethernet port for the example. Any
single Traffic Ethernet port may be used.
HRG Block Diagram – Gigabit Ethernet 1:1 Router Mode
Figure 5-22. HRG Gigabit Ethernet 1:1 Cabling Example – Router Mode
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–27
5.5
Cabling to the Advanced VSAT CDM-850
1) For information on the CDM-850’s 1:1 auto-enable functionality, see:
• Chapter 4. MODEM AND SWITCH CONFIGURATION
• CDM-850 Remote Router Installation and Operation Manual
(CEFD Part No. MN-CDM850)
2) For information on the cables and cable assemblies specified in this section, see
Appendix A. CABLE DRAWINGS.
5.5.1
CRS-170A CDM-850 Control and IF Interface Connections Using
Cabling Kit KT-0000160
The CDM-850 employs 10/100/1000 Ethernet (Gigabit Ethernet, also identified throughout
this chapter as GigE or GbE) as its sole terrestrial data interface. All cables and switches
must be user-supplied. See Section 5.5.2 for the CDM-850 Gigabit Ethernet terrestrial data
interface configuration and connection examples and details.
You must use Comtech EF Data’s KT-0000160 1:1 Redundancy Control/IF Interface Cabling Kit (Section
5.2.1) for your control and L-Band Unit-to-Switch cabling connections. Figure 5-23 and Figure 5-24 show
how to connect a pair of CDM-850s together with the CRS-170A L-Band 1:1 Redundancy Switch module.
The table included with each figure lists the items you will need from this kit for your initial setup.
IMPORTANT: It is ESSENTIAL that you make the Control and the IF Rx and Tx connections
correctly. See Section 5.5.1.1 for details about the CDM-850 Unit-to-Switch Control
Interface connection, and Section 5.5.1.2 for details about the CDM-850 Unit-to-Switch IF
Interface connections.
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–28
5.5.1.1
Unit-to-Switch Control Interface Connection
1) Excluding the CDM-850s, the KT-0000160 CRS-170A L-Band 1:1 Redundancy Kit (Section
5.2.1) provides all components shown in Figure 5-23.
2) When you connect the Control Interface cables between the CRS-170A and the
CDM-850s, make sure that you securely fasten the screw locks on the Type ‘D’
connectors. This prevents accidental disconnection of the cables, particularly when you
are removing and replacing a standby unit.
CEFD Part No.
Qty
Description
CA/WR9378-4
2
Control Cable – Universal, DB-9M, 4’
Figure 5-23. CDM-850 Unit-to-Switch Control Connections
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–29
5.5.1.2
Unit-to-Switch IF Interface Connection
Excluding the CDM-850s, the KT-0000160 CRS-170A L-Band 1:1 Redundancy Kit (Section
5.2.1) provides all components shown in Figure 5-24.
IMPORTANT: The Tx IF from ‘Unit A’ connects to the Tx IF port ‘J5 | Tx A’ on the CRS-170A;
similarly, the Tx IF from ‘Unit B’ connects to the Tx IF port ‘J6 | Tx B’ on the CRS-170A. The
same logic applies for the Rx IF connections. It is important to note that failure to observe
this requirement will result in system malfunction.
CEFD Part No.
Qty
Description
CA/RF10453-4
4
RoHS-Compliant Cable – IF (Tx/Rx), 50Ω Type ‘N’, 4’
Figure 5-24. CDM-850 Unit-to-Switch L-Band IF Connections
CRS-170A L-Band 1:1 Redundancy Switch
MN/CRS170A.IOM
Cables and Connections
Revision 14
5–30
5.5.2
Unit-to-User Data Interface Connections and Examples
In addition to the control and IF Unit-to-Switch cabling shown previously, the CDM-850 features an
eight-port 10/100/1000 Gigabit Ethernet data interface.
5.5.2.1
CDM-850 Managed Switch Mode (Ethernet Bridge Mode)
Figure 5-25 shows the block diagram for a CDM-850 1:1 redundant configuration in in Managed Switch
Mode (also called Ethernet Bridge Mode). Figure 5-26 shows the cabling example for this setup. This
configuration requires no cabling kit – you must use user-provided Ethernet cables and Layer 2 switches
for direct connection to the modem via one to eight RJ-45 ports. Both figures depict all eight ports used.
Figure 5-25. CDM-850 Block Diagram –Gigabit Ethernet 1:1 Managed Switch Mode