CF18, CF25, CF35, CF40, CF50

Compressor Cooler Operating manual EN PORTABLE REFRIGERATION CF SERIES

CF18, CF25, CF35, CF40, CF50

2 Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it. The manufacturer cannot be held liable for damage resulting from improper usage or incorrect operation. Contents 1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 5 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 6 Function description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 8 Cleaning and maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 9 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 11 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

CF18, CF25, CF35, CF40, CF50

Explanation of symbols 3 1 Explanation of symbols D ! ! A I 2 Safety instructions The manufacturer accepts no liability for damage in the following cases: • Damage to the product resulting from mechanical influences and excess voltage • Alterations to the product without express permission from the manufacturer • Use for purposes other than those described in the operating manual DANGER! Safety instruction: Failure to observe this instruction will cause fatal or serious injury. WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury. CAUTION! Safety instruction: Failure to observe this instruction can lead to injury. NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product. NOTE Supplementary information for operating the product.

CF18, CF25, CF35, CF40, CF50

4 2.1 General safety D DANGER! • When using the device on boats: If the device is powered by the AC mains, ensure that the power supply is protected with a ground fault interrupter circuit. ! WARNING! • Do not operate the device if it is visibly damaged. • If this device's power cable is damaged, it must be replaced by the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards. • This device may only be repaired by qualified personnel. Improper repairs can lead to considerable hazards. • This device can be used by children aged 8 years or over, as well as by persons with diminished physical, sensory or mental capacities or a lack of experience and/or knowledge, providing they are supervised or have been taught how to use the device safely and are aware of the resulting risks. • Cleaning and user maintenance must not be carried out by children without supervision. • Children must not play with the device. • Children must be supervised to ensure that they do not play with the device. • Always keep and use the device out of the reach of children under the age of 8 years. • Do not store any explosive substances such as spray cans with a flammable propellant in the device. ! CAUTION! • Disconnect the device from the power supply – before each cleaning and maintenance – after every use • Food may only be stored in its original packaging or in suitable containers. A NOTICE! • Check that the voltage specification on the type plate corresponds to that of the energy supply.

CF18, CF25, CF35, CF40, CF50

Safety instructions 5 • Only connect the device as follows: – With the DC cable to a DC plug socket in the vehicle (e. g. cigarette lighter) – Or with the AC connection cable to the AC mains supply • Never pull the plug out of the socket by the cable. • If the cooler is connected to the DC socket: Disconnect the cooler and other power consuming devices from the battery before connecting the quick charging device. • If the cooler is connected to the DC socket: Disconnect the cooler or switch it off when you turn off the engine. Otherwise you may dis- charge the battery. • The cooling device is not suitable for transporting caustic materials or materials containing solvents. • The cooling device contains inflammable cyclopentane in the insulation. The gases in the insulation material require special disposal procedures. Deliver the device at the end of its life-cycle to an appro- priate recycling. 2.2 Operating the device safely ! CAUTION! • Before starting the device, ensure that the power supply line and the plug are dry. A NOTICE! • Do not use electrical devices inside the cooler unless they are recommended by the manufacturer for the purpose. • Do not place the device near naked flames or other heat sources (heaters, direct sunlight, gas ovens etc.). • Danger of overheating! Ensure at all times that there is sufficient ventilation so that the heat that arises during operation does not build up. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate. • Ensure that the ventilation openings are not covered. • Do not fill the inner container with ice or fluid. • Never immerse the device in water. • Protect the device and the cable against heat and moisture.

Scope of delivery

CF18, CF25, CF35, CF40, CF50 6 3 Scope of delivery Item Quantity Description 1 1 Cooler 2 1 Connection cable for DC connection 3 1 Only CF35, CF40, CF50 Connection cable for AC connection 4 2 Only CF35, CF40, CF50 Carrying handle, consisting of: – 2 holders – 1 handle – 4 fastening screws – 1 Only CF18 Plastic grille divider – 1 Only CF35 Powdercoated steel evaporator protector – 1 Only CF40, CF50 Powdercoated steel basket – 1 Operating manual 4 2 3 1 1

CF18, CF25, CF35, CF40, CF50

Accessories 7 4 Accessories Available as accessories (not included in the scope of delivery): If you have questions regarding the accessories, contact your local service partner. 5 Intended use The cooler is suitable for cooling and freezing foods. The cooler is designed to be operated from: • a DC on-board power supply of a vehicle, boat or caravan • a DC auxiliary battery • an AC power supply (CF35, CF40, CF50) For operating CF 18, CF25 at AC mains you need an AC/DC power supply rectifier (accessory). ! 6 Function description The cooler can refrigerate or freeze food products. A fast-acting and efficient cooling system provides low maintenance cooling performance with a compressor and con- trol module. The cooler is designed for mobile use and can be carried by using a folding carrying bracket (CF18), two recessed grips (CF25) or two removable carrying handles (CF35, CF40, CF50). The cooler can withstand a short-term inclination of 30°, for example on boats. Description Ref. no. For CF18, CF25: AC/DC power supply rectifier EPS-817 9109002086 CAUTION! Health hazard! Please check if the cooling capacity of the device is suitable for storing the food or medicine you wish to cool.

CF18, CF25, CF35, CF40, CF50

8 6.1 Scope of functions 6.2 Operating and display elements Latch for lid CF18 CF25 CF35, CF40, CF50 Power supply with priority circuit for connecting to the power supply – –  Battery monitor to protect the vehicle battery 2-level 3-level Turbo mode for rapid cooling –   Display with temperature gauge (switches off automatically at low battery voltage) –   Temperature setting rotary-knob two buttons in steps of 1 °C (2 °F) Removable carrying handles – –  1 CF 25, CF 35, CF 40 2

CF18, CF25, CF35, CF40, CF50

Function description 9 Operating panel and DC power supply inlet (CF18) Item Description Explanation 1 TEMPERATURE Temperature controller, cooling temperature at the end positions: COLD: +10 °C (+50 °F) FREEZE: –18 °C (0 °F) 2 POWER Status indication LED lights up green: Device is switched on and ready for operation LED lights up yellow: Set temperature has been reached 3 ERROR LED flashes red: Device is switched on but not ready for operation 4 BATTERY MONITOR Switch-on device/battery monitor: 0: Device is switched off HIGH: Device is switched on, battery monitor is in HIGH mode LOW: Device is switched on, battery monitor is in LOW mode 5 12/24 Vg DC voltage supply inlet CF 18 1 2 3 4 5 3

CF18, CF25, CF35, CF40, CF50

10 Operating panel (CF25, CF35, CF40, CF50) Item Description Explanation 1 ON OFF Switches the cooler on or off when the button is pressed for between one and two seconds 2 POWER Status indication LED lights up green: Compressor is on LED lights up orange: Compressor is off LED flashes orange: Display switched off automatically due to low battery voltage 3 ERROR LED flashes red: Device is switched on but not ready for operation 4 SET Selects the input mode – Temperature setting – Celsius or Fahrenheit display – Set battery monitor 5 – Display, shows the information 6 UP + Press once to increase the value 7 DOWN – Press once to decrease the value CF 25, CF 35, CF 40, CF 50 ON OFF SET POWER UP + DOWN – ERROR ° 1 3 4 5 6 7 2 4

CF18, CF25, CF35, CF40, CF50

Function description 11 Connection sockets (CF25, CF35, CF40, CF50) Item in fig. 5 Description 1 DC voltage supply inlet 2 Emergency switch Item in fig. 6 Description 1 AC voltage supply inlet 2 Fuse holder 3 DC voltage supply inlet 4 Emergency switch 1 CF 25 EMERGENCY OVERRIDE NORMAL USE 2 5 100-240V~AC FUSE 12/24V DC 1 2 3 CF 35, CF 40, CF 50 EMERGENCY OVERRIDE NORMAL USE 4 6

CF18, CF25, CF35, CF40, CF50

12 7 Operation 7.1 Before initial use I Mounting the handles The handles are enclosed unassembled. If you wish to attach the handles, proceed as follows: ➤ Make a handle by putting two holders (1) and a handle (2) together. ➤ Fasten the grip with the enclosed screws in the holes provided. NOTE Before starting your new cooler for the first time, you should clean it inside and outside with a damp cloth for hygienic reasons (please also refer to the chapter “Cleaning and maintenance” on page 22). 1 2 1 CF 35, CF 40, CF 50 7

CF18, CF25, CF35, CF40, CF50

Operation 13 Turning the lid around (CF50) You can turn the lid around if you want to open the lid from the other side. To do this, proceed as follows: ➤ Open the lid and pull it out (A). ➤ Turn the lid. ➤ Insert the lid in the lid holders on the opposite side of the cooler (B). Selecting the temperature units (CF25, CF35, CF40, CF50) You can switch the temperature display between Celsius and Fahrenheit. This is how to do it: ➤ Switch on the cooler. ➤ Press the “SET” button (fig. 4 4, page 10) twice. ➤ Use the “UP +” (fig. 4 6, page 10) and “DOWN –” (fig. 4 7, page 10) buttons to select Celsius or Fahrenheit. ✓ The selected temperature units then appear in the display for a few seconds. The display flashes several times before it returns to the current temperature. CF 50 A B 8

CF18, CF25, CF35, CF40, CF50

14 7.2 Energy saving tips • Choose a well ventilated location which is protected from direct sunlight. • Allow warm food to cool down first before placing it in the cooling device. • Do not open the cooling device more often than necessary. • Do not leave the cooling device open for longer than necessary. • Defrost the cooling device once a layer of ice forms. • Avoid unnecessarily low temperatures. 7.3 Connecting the cooler Connecting to a battery (vehicle or boat) The cooler can be operated with 12 Vg or 24 Vg. A For safety reasons the cooler is equipped with an electronic system to prevent polarity reversal. This protects the cooler against short-circuiting when connecting to a battery. Using the fused DC plug A ➤ Plug the DC connection cable (fig. 1 2, page 6) into the DC power supply inlet of the cooler (fig. 5 1, page 11/fig. 6 3, page 11). ➤ Connect the connection cable to a DC power outlet. NOTICE! Danger of damage! Disconnect the cooler and other consumer units from the battery before you connect the battery to a quick charging device. Overvoltage can damage the electronics of the device. NOTICE! Danger of damage! For protection of the device the DC cable supplied includes a fuse inside the plug. Do not remove the fused DC plug. Only use the DC cable supplied.

CF18, CF25, CF35, CF40, CF50

Operation 15 Connecting to an AC power supply (e.g. in the home or office) (CF35, CF40, CF50) D The coolers have an integrated multi-voltage power supply with priority circuit for connecting to an AC voltage source. The priority circuit automatically switches the cooler to power supply operation if the device is connected to an AC power supply, even if the DC connection cable is still attached. When switching between the AC power supply and the battery supply, the red LED may light up briefly. ➤ Plug the AC connection cable (fig. 1 3, page 6) into the AC power supply inlet of the cooler (fig. 6 1,page 11). ➤ Connect the connection cable to the AC power outlet. 7.4 Using the battery monitor The device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to an on-board DC supply. If the cooler is operated when the vehicle ignition is switched off, the cooler switches off automatically as soon as the supply voltage falls below a set level. The cooler will switch back on once the battery has been recharged to the restart voltage level. A DANGER! Danger of electrocution! • Never handle plugs and switches with wet hands or if you are standing on a wet surface. • If you are operating your cooler on board a boat from a power supply connection of 100 – 240 Vw, you must install a residual current circuit breaker between the 100 – 240 V AC power supply and the cooler. Seek advice from a trained technician. NOTICE! Danger of damage! When switched off by the battery monitor, the battery will no longer be fully charged. For in-vehicle installations, avoid repeated starting and shutting off of the engine. Allow the vehicle to recharge the battery before powering the cooler on.

CF18, CF25, CF35, CF40, CF50

16 In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and “MED” (see the following table). Selecting the battery monitor mode (CF18) ➤ Slide the selection switch (fig. 3 4, page 9) to select the battery monitor mode. Selecting the battery monitor mode (CF25, CF35, CF40, CF50) ➤ Switch on the cooler. ➤ Press the “SET” button (fig. 4 4, page 10) three times. ➤ Use the “UP +” (fig. 4 6, page 10) and “DOWN –” (fig. 4 7, page 10) buttons to select the battery monitor mode. ✓ Display will be as follows: Lo (LOW), Πed (MED) or HI (HIGH) ✓ The selected mode then appears in the display for a few seconds. The display flashes several times before it returns to the current temperature. I CF18 CF25, CF35, CF40, CF50 Battery monitor mode LOW HIGH LOW MED HIGH Switch-off voltage at 12 V 10.4 V 11.5 V 10.1 V 11.4 V 11.8 V Restart voltage at 12 V 11.5 V 12.5 V 11.1 V 12.2 V 12.6 V Switch-off voltage at 24 V 22.1 V 24.0 V 21.5 V 24.1 V 24.6 V Restart voltage at 24 V 23.6 V 25.4 V 23.0 V 25.3 V 26.2 V NOTE When the cooler is supplied by the starter battery, select the battery monitor mode “HIGH”. If the cooler is connected to a supply battery, the battery monitor mode “LOW” will suffice. If you wish to operate the cooler from the AC power supply, set the battery monitor to the “LOW” position.

CF18, CF25, CF35, CF40, CF50

Operation 17 7.5 Using the cooler A ➤ Place the cooler on a firm foundation. Make sure that the ventilation slots are not covered and that the heated air can dissipate. I ➤ Close the cooler, see chapter “Connecting to a battery (vehicle or boat)” on page 14. I CF18 ➤ Set the slide switch (fig. 3 4, page 9) to "HIGH" when power is supplied by your vehicle's starter battery. ➤ Set the slide switch (fig. 3 4, page 9) to "LOW" when power is supplied by an external DC power supply source. ✓ The “POWER” LED is lit green. ✓ The cooler starts cooling the interior. ✓ When the cooling temperature has been reached, the “POWER” LED is lit yellow. NOTICE! Danger of overheating! Ensure at all times that there is sufficient ventilation so that the heat that generated during operation can dissipate. Ensure that the ventilation slots are not covered. The cooler MUST maintain a MINIMUM of 50 mm away from walls or similar surfaces which could restrict important air flow requirements of the cooling system. NOTE Place the cooler as shown (fig. 1, page 6). If you operate the box in a different position it can be damaged. NOTE If you wish to operate the cooler from the AC power supply, set the battery monitor to the “LOW” position.

CF18, CF25, CF35, CF40, CF50

18 CF25, CF35, CF40, CF50 ➤ Press the “ON/OFF” button (fig. 4 1, page 10) for between one and two seconds. ✓ The “POWER” LED lights up. ✓ The display (fig. 4 5, page 10) switches on and shows the current temperature. I ✓ The cooler starts cooling the interior. I Latching the cooler lid (CF35, CF40) ➤ Close the lid. ➤ Press the latch (fig. 2 1, page 8) down, until it latches in place audibly. 7.6 Setting the temperature A CF18 ➤ Set the cooling level with the temperature controller (fig. 3 1, page 9). CF25, CF35, CF40, CF50 ➤ Press the “SET” button (fig. 4 4, page 10) once. ➤ Use the “UP +” (fig. 4 6, page 10) and “DOWN –” (fig. 4 7, page 10) buttons to select the cooling temperature. ✓ The cooling temperature appears in the display for a few seconds. The display flashes several times and then the current temperature is displayed again. NOTE The temperature displayed is that of the middle of the interior. The temperatures elsewhere can deviate from this temperature. NOTE During low voltage: If switched off by the battery monitor due to low voltage, the display goes blank, and the LED “POWER” flashes orange. NOTICE! Danger from excessively low temperature! Ensure that the only those objects are placed in the cooler that are intended to be cooled at the selected temperature.

CF18, CF25, CF35, CF40, CF50

Operation 19 7.7 Using the Emergency Switch The emergency override switch ((fig. 5 2, page 11 and fig. 6 4, page 11) is located in the connection panel. ➤ For normal operation the switch should be in the NORMAL USE position. ➤ In the unlikely event of an electronic control failure slide the switch to EMERGENCY OVERRIDE. I 7.8 Switching off the cooler ➤ Empty the cooler. ➤ Switch the cooler off. ➤ Pull out the connection cable. If you do not want to use the cooler for a longer period of time: ➤ Leave the lid slightly open. This prevents odor build-up. 7.9 Defrosting the cooler Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity. Defrost the device in good time to avoid this. A To defrost the cooler, proceed as follows: ➤ Remove the contents. ➤ If necessary, place them in another cooling device to keep them cool. ➤ Switch off the device. ➤ Leave the lid open. ➤ Wipe off the defrosted water. NOTE In this position the appliance will run all the time and will therefore per- form as a freezer only. NOTICE! Danger of damage! Never use hard or pointed tools to remove ice or to loosen objects which have frozen in place.

CF18, CF25, CF35, CF40, CF50

20 7.10 Replacing the AC fuse (CF35, CF40, CF50) D ➤ Pull off the connection cable. ➤ Pry out the fuse insert (fig. 6 2, page 11) with a screwdriver. ➤ Replace the defective fuse with a new one that has the same rating (T4AL 250 V). ➤ Press the fuse insert back into the housing. 7.11 Replacing the DC plug fuse ➤ Pull the adapter sleeve (4) off of the plug. ➤ Unscrew the screw (5) out of the upper half of the housing (1). ➤ Carefully raise the upper half of the housing from the lower (6) half. ➤ Take out the contact pin (3). ➤ Replace the defective fuse (2) with a new fuse of the same type and rating (8 A 32 V). ➤ Re-assemble the plug in the reverse order. DANGER! Danger of electrocution! Disconnect the connection cable before you replace the device fuse. 1 2 3 4 5 6 9

CF18, CF25, CF35, CF40, CF50

Operation 21 7.12 Replacing the light bulb (CF25, CF35, CF40, CF50) ➤ Press the switch pin (2) downwards so that the transparent part (1) of the lamp can be removed at the front. ➤ Replace the light bulb. I ➤ Press the transparent part of the lamp back into the housing. NOTE The LEDs in the light bulb must facing the transparent part of the lamp. 1 2 0

Cleaning and maintenance

CF18, CF25, CF35, CF40, CF50 22 8 Cleaning and maintenance ! A ➤ Occasionally clean the device interior and exterior with a damp cloth. ➤ Make sure that the air inlet and outlet vents on the device are free of any dust and dirt, so that heat can be released and the device is not damaged. 9 Guarantee The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer. For repair and guarantee processing, please include the following documents when you send in the device: • A copy of the receipt with purchasing date • A reason for the claim or description of the fault WARNING! Always disconnect the device from the power supply before you clean and service it. NOTICE! Risk of damage • Never clean the cooler under running water or in dish water. • Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the cooler.

CF18, CF25, CF35, CF40, CF50

Troubleshooting 23 10 Troubleshooting Fault Possible cause Suggested remedy Device does not function, LED does not glow. No voltage was detected in the DC power outlet. In most vehicles the ignition must be turned on before power will be supplied to the DC power outlet. No voltage present in the AC voltage outlet. Try using another plug outlet. The device fuse is defective. Replace the device fuse, see chapter “Replacing the AC fuse (CF35, CF40, CF50)” on page 20. The integrated power supply adapter is defective. This can only be repaired by an authorized repair center. The device does not cool (plug is inserted, “POWER” LED is lit). Defective compressor. This can only be repaired by an authorized repair center. The device does not cool (plug is inserted, “POWER” LED flashes orange, display is switched off). Battery monitor is set too high. Select a lower battery monitor setting. Battery voltage is too low. Test the battery and charge it as needed. When operating from the DC outlet: The ignition is on and the device is not working and the LED is not lit. The DC outlet is dirty. This results in a poor electrical contact. If the plug of your cooler becomes very warm in the DC outlet, either the DC outlet must be cleaned or the plug has not been assembled correctly. The fuse of the DC plug has blown. Replace the fuse in the DC plug, see chapter “Replacing the DC plug fuse” on page 20. The vehicle fuse has blown. Replace the vehicle’s DC outlet fuse. Please refer to your vehicle’s operating manual.

CF18, CF25, CF35, CF40, CF50

24 11 Disposal ➤ Place the packaging material in the appropriate recycling waste bins wherever possible. M If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations. The display shows an error message (e.g. “Err1”) and the appli- ance does not cool. The appliance has switched off due to an internal fault. This can only be repaired by an authorized repair center. The interior light of a compartment flashes. The lid of the compartment has been left open for more than three minutes. Close the lid of the compartment. Fault Possible cause Suggested remedy

CF18, CF25, CF35, CF40, CF50

Technical data 25 12 Technical data CF18 CF25 Connection voltage: 12/24 Vg Rated current – 12 Vg: 3.1 A 6.8 A – 24 Vg: 1.9 A 3.0 A – 100 – 240 Vw: – – Cooling capacity: +10 °C to –18 °C (+50 °F to +0.4 °F) Storage volume: 18 l 23 l Climate class: N, ST, T Ambient temperature: 18 °C to 43 °C (+50 °F to 109.4 °F) Noise emission: – Refrigerant quantity: 38 g 40 g CO2 equivalent: 0.054 t 0.057 t Global warming potential (GWP): 1430 Dimensions (W x H x D) in mm: 465 x 414 x 300 260 x 425 x 550 Weight: 12 kg 12.7 kg Test/certificates:

CF18, CF25, CF35, CF40, CF50

26 CF35 CF40 Connection voltage: 12/24 Vg and 100 – 240 Vw Rated current – 12 Vg: 6.0 A – 24 Vg: 3.0 A – 100 – 240 Vw: 1.3 A to 0.7 A Cooling capacity: +10 °C to –18 °C (+50 °F to +0.4 °F) Storage volume: 31 l 37 l Climate class: N, ST, T Ambient temperature: 18 °C to 43 °C (+50 °F to 109.4 °F) Noise emission: 45 dB(A) Refrigerant quantity: 45 g CO2 equivalent: 0.064 t Global warming potential (GWP): 1430 Dimensions (W x H x D) in mm: 360 x 385 x 580 360 x 445 x 580 Weight: 15.5 kg 17.2 kg Test/certificates:

CF18, CF25, CF35, CF40, CF50

Technical data 27 I The refrigerant circuit contains R134a. Contains fluorinated greenhouse gases Hermetically sealed equipment CF50 Connection voltage: 12/24 Vg and 100 – 240 Vw Rated current – 12 Vg: 7.0 A – 24 Vg: 3.0 A – 100 – 240 Vw: 1.3 A to 0.7 A Cooling capacity: +10 °C to –18 °C (+50 °F to +0.4 °F) Storage volume: 47 l Climate class: N, ST, T Ambient temperature: 18 °C to 43 °C (+64.4 °F to 109.4 °F) Noise emission: 45 dB(A) Refrigerant quantity: 45 g CO2 equivalent: 0.064 t Global warming potential (GWP): 1430 Dimensions (W x H x D) in mm: 630 x 480 x 360 Weight: 18.5 kg Test/certificates: NOTE If the ambient temperature is above 32 °C (90 °F), the minimum temperature cannot be attained.

Dometic Austria GmbH

Neudorferstraße 108 A-2353 Guntramsdorf  +43 2236 908070  +43 2236 90807060 Mail: [email protected] BENELUX Dometic Branch Office Belgium Lourdesstraat 84 B-8940 Geluwe  +32 2 3598040  +32 2 3598050 Mail: [email protected] BRAZIL Dometic DO Brasil LTDA Avenida Paulista 1754, conj. 111 SP 01310-920 Sao Paulo  +55 11 3251 3352  +55 11 3251 3362 Mail: [email protected] DENMARK Dometic Denmark A/S Nordensvej 15, Taulov DK-7000 Fredericia  +45 75585966  +45 75586307 Mail: [email protected] FINLAND Dometic Finland OY Mestarintie 4 FIN-01730 Vantaa  +358 20 7413220  +358 9 7593700 Mail: [email protected] FRANCE Dometic SAS ZA du Pré de la Dame Jeanne B.P. 5 F-60128 Plailly  +33 3 44633525  +33 3 44633518 Mail : [email protected] GERMANY Dometic WAECO International GmbH Hollefeldstraße 63 · D-48282 Emsdetten  +49 (0) 2572 879-0  +49 (0) 2572 879-300 Mail: [email protected] HONG KONG Dometic Group Asia Pacific Suites 2207-11 · 22/F · Tower 1 The Gateway · 25 Canton Road, Tsim Sha Tsui · Kowloon  +852 2 4611386  +852 2 4665553 Mail: [email protected] HUNGARY Dometic Zrt. Sales Office Kerékgyártó u. 5. H-1147 Budapest  +36 1 468 4400  +36 1 468 4401 Mail: [email protected] ITALY Dometic Italy S.r.l. Via Virgilio, 3 I-47122 Forlì (FC)  +39 0543 754901  +39 0543 754983 Mail: [email protected] JAPAN Dometic KK Maekawa-Shibaura, Bldg. 2 2-13-9 Shibaura Minato-ku Tokyo 108-0023  +81 3 5445 3333  +81 3 5445 3339 Mail: [email protected] MEXICO Dometic Mx, S. de R. L. de C. V. Circuito Médicos No. 6 Local 1 Colonia Ciudad Satélite CP 53100 Naucalpan de Juárez Estado de México  +52 55 5374 4108  +52 55 5393 4683 Mail: [email protected] NETHERLANDS Dometic Benelux B.V. Ecustraat 3 NL-4879 NP Etten-Leur  +31 76 5029000  +31 76 5029019 Mail: [email protected] NEW ZEALAND Dometic New Zealand Ltd. PO Box 12011 Penrose Auckland 1642  +64 9 622 1490  +64 9 622 1573 Mail: [email protected] NORWAY Dometic Norway AS Østerøyveien 46 N-3232 Sandefjord  +47 33428450  +47 33428459 Mail: [email protected] POLAND Dometic Poland Sp. z o.o. Ul. Puławska 435A PL-02-801 Warszawa  +48 22 414 3200  +48 22 414 3201 Mail: [email protected] PORTUGAL Dometic Spain, S.L. Branch Office em Portugal Rot. de São Gonçalo nº 1 – Esc. 12 2775-399 Carcavelos  +351 219 244 173  +351 219 243 206 Mail: [email protected] RUSSIA Dometic RUS LLC Komsomolskaya square 6-1 RU-107140 Moscow  +7 495 780 79 39  +7 495 916 56 53 Mail: [email protected] SINGAPORE Dometic Pte Ltd 18 Boon Lay Way 06–141 Trade Hub 21 Singapore 609966  +65 6795 3177  +65 6862 6620 Mail: [email protected] SLOVAKIA Dometic Slovakia s.r.o. Sales Office Bratislava Nádražná 34/A 900 28 Ivánka pri Dunaji / +421 2 45 529 680 Mail: [email protected] SOUTH AFRICA Dometic (Pty) Ltd. Regional Office South Africa & Sub-Saharan Africa 2 Avalon Road West Lake View Ext 11 Modderfontein 1645 Johannesburg  +27 87 3530380 Mail: [email protected] SPAIN Dometic Spain S.L. Avda. Sierra del Guadarrama, 16 E-28691 Villanueva de la Cañada Madrid  +34 902 111 042  +34 900 100 245 Mail: [email protected] SWEDEN Dometic Scandinavia AB Gustaf Melins gata 7 SE-42131 Västra Frölunda  +46 31 7341100  +46 31 7341101 Mail: [email protected] SWITZERLAND Dometic Switzerland AG Riedackerstrasse 7a CH-8153 Rümlang  +41 44 8187171  +41 44 8187191 Mail: [email protected] UNITED ARAB EMIRATES Dometic Middle East FZCO P. O. Box 17860 S-D 6, Jebel Ali Freezone Dubai  +971 4 883 3858  +971 4 883 3868 Mail: [email protected] UNITED KINGDOM Dometic UK Ltd. Dometic House, The Brewery Blandford St. Mary Dorset DT11 9LS  +44 344 626 0133  +44 344 626 0143 Mail: [email protected] USA Dometic RV Division 1120 North Main Street Elkhart, IN 46515  +1 574-264-2131 AUSTRALIA Dometic Australia Pty. Ltd. 1 John Duncan Court · Varsity Lakes QLD 4227  1800 212121 · +61 7 55076001 Mail: [email protected] dometic.com 4445102487 02/2018