DirectOut Technologies D.O.TEC M.1k2 Hardware Manual
Read Online
Read the DirectOut Technologies D.O.TEC M.1k2 Hardware Manual online using the built-in PDF viewer.
Text of the manual
page 2 of 44
M.1k2 Hardware Guide - Version 1.3
Copyright
All rights reserved. Permission to reprint or electronically reproduce any document or
graphic in whole or in part for any reason is expressly prohibited, unless prior written
consent is obtained from the DirectOut GmbH.
All trademarks and registered trademarks belong to their respective owners. It cannot
be guaranteed that all product names, products, trademarks, requisitions, regulations,
guidelines, specifications and norms are free from trade mark rights of third parties.
All entries in this document have been thoroughly checked; however no guarantee for
correctness can be given.
DirectOut GmbH cannot be held responsible for any misleading or incorrect
information provided throughout this manual.
DirectOut GmbH reserves the right to change specifications at any time without notice.
DirectOut Technologies® is a registered trademark of the DirectOut GmbH.
© DirectOut GmbH, 2016
page 3 of 44
M.1k2 Hardware Guide - Version 1.3
Table of contents
About This Document
5
How to Use This Document........................................................................... 5
Conventions................................................................................................... 5
CHAPTER 1: Overview
6
Introduction.................................................................................................... 6
Feature Summary........................................................................................... 7
Applications.................................................................................................... 7
CHAPTER 2: Legal issues & facts
8
Before Installing This Device.......................................................................... 8
Defective Parts/Modules .............................................................................. 8
First Aid (in case of electric shock)................................................................. 9
Updates........................................................................................................ 10
Conditions of Warranty................................................................................ 10
Intended Operation ..................................................................................... 10
Conformity & Certificates............................................................................ 11
Contact......................................................................................................... 11
Contents....................................................................................................... 12
CHAPTER 3: Installation
13
Installing the Device..................................................................................... 13
Network integration...................................................................................... 16
CHAPTER 4: Operation
18
Introduction.................................................................................................. 18
Global Control............................................................................................... 18
Device State & RESET................................................................................. 19
User data (Serial, MIDI, GPO)......................................................................20
Clocking........................................................................................................ 21
Remote Operation........................................................................................22
CHAPTER 5: Troubleshooting and Maintenance
23
Troubleshooting............................................................................................23
Maintenance.................................................................................................23
CHAPTER 6: Technical Data
24
Appendix A - Emergency recovery
26
Appendix B - DSUB-9 Pin assignments
27
RS-232......................................................................................................... 27
RS-4xx.......................................................................................................... 27
GPO.............................................................................................................. 27
page 4 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix C - Installing / Replacing I/O modules
28
Modules.......................................................................................................29
Appendix D - How to - Network
30
Appendix E - Firmware Update Instruction
32
Appendix F - USB Serial Driver Installation
36
Index
39
page 5 of 44
M.1k2 Hardware Guide - Version 1.3
About This Document
About This Document
How to Use This Document
This document guides you through the installation and operation of the M.1K2. For
information about the graphical user interface (GUI) please consult the offline help
available from our website or use the online help within the gui.
Use the Table of Contents at the beginning of the manual or Index Directory at the
end of the document to locate help on a particular topic. You can access more
information and latest news by visiting on the DirectOut website at
www.directout.eu.
Conventions
The following symbols are used to draw your attention to:
TIPS!
indicate useful tips and shortcuts.
NOTES!
are used for important points of clarification or cross references.
WARNINGS!
alert you when an action should always be observed.
page 6 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 1: Overview
CHAPTER 1: Overview
Introduction
The M.1K2 is a 16 port MADI Routing System. It provides routing of whole ports
down to single channel level offering a 1024 by 1024 crosspoint matrix.
You can distribute MADI signals en bloc in a port matrix and you may also create
your own MADI stream using the channel matrix. PolySync™ provides the ability
to use different clock sources on individual ports. So the router may be divided into
single ‘clock groups’ that can run at different sample rates.
Port redundancy may be applied to have a spare signal that will be used when an
input signal breaks. Two extra matrices may route serial data and MIDI data - that is
embedded into the MADI signal - independently from the audio signal.
Doppelganger (Device Mirroring) allows one (or more) M.1K2s to be confi gured
to act as a slave to one master device. All confi guration data (crosspoints, port
confi guration, labels etc.) is synchronized continuously.
SNMP Simple Network Management Protocol (v1/v2) allows for monitoring of
essential device information such as power supply state; temperature; MADI
signal/synchronization state.
More features such as I/O labelling, snapshot and user management offer the
chance to personalize your setup all-embracing.
page 7 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 1: Overview
Feature Summary
MADI I/Os
2 x slots with eight MADI ports each
Module types: coaxial (BNC), optical SC (multi-mode)
and SFP (multi-mode)
single-mode upon request
MADI Formats
56/64 channel, 48k/96k Frame, S/MUX 2/4
Sample Rates
30 kHz to 50 kHz
(and their multiples - 2FS, 4FS)
Clock Inputs
1 x Word clock coaxial BNC
75 Ω termination switchable
1 x Video
coaxial BNC
75 Ω termination switchable
Black Burst (PAL, NTSC)
Clock Outputs
2 x Word clock coaxial BNC
Serial Data / MIDI
1 x RS232
DSUB-9
1 x RS422/485 DSUB-9
1 x MIDI in/out (DIN)
GPO
4 x GPO
DSUB-9
Device Monitoring
SNMP v1/v2
Device Mirroring
Doppelgaenger Mode
Control Plug-Ins
Telnet,Pro-Bel SWP-08 (network and serial), MIDI,
Jupiter, JSON
USB Port
USB 2.0 port for virtual COM port (RS 232)
Power Supply
This device is equipped with two wide range power
supplies (84 V to 264 V AC / 47 Hz to 63 Hz / safety
class 1)
Applications
M.1K2 can be used for distribution and creation of whole MADI streams, routing
of single audio channels between MADI streams and independent routing of
embedded serial data and MIDI data.
Typical applications include:
• distribution of audio signals in OB van with integrated switching protocol (e.g.
SWP08)
• central switch in studio environments - PolySync™ and browser control
• connection between remote mic preamps and mixing consoles (serial matrix)
• show control using snapshots
• fallback system - port redundancy, device mirroring
• ...
page 8 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 2: Legal issues & facts
CHAPTER 2: Legal issues & facts
Before Installing This Device
WARNING!
Please read and observe all of the following notes before installing
this product:
• Check the hardware device for transport damage.
• Any devices showing signs of mechanical damage or damage from the
spillage of liquids must not be connected to the mains supply, or
disconnected from the mains immediately by pulling out the power lead.
• All devices must be grounded. The device is grounded through its
IEC power connections.
• All devices must be connected to the mains using the three-cord power
leads supplied with the system. Only supply electrical interfaces with the
voltages and signals described in these instructions.
• Do not use the device at extreme temperatures. Proper operation can
only be guaranteed between temperatures of 5º C and 45º C and a
maximum relative humidity of 80 %, non-condensing.
• The cabinet of the device will heat up. Do not place the device close
to heating sources (e.g. heaters). Observe the environmental conditions.
Defective Parts/Modules
WARNING!
This device contains no user-serviceable parts. Therefore do not open the device.
In the event of a hardware defect, please send the device to your DirectOut
representative together with a detailed description of the fault.
We would like to remind you to please check carefully whether the failure is
caused by erroneous configuration, operation or connection before sending parts
for repair.
page 9 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 2: Legal issues & facts
First Aid (in case of electric shock)
WARNING!
• Do not touch the person or his/her clothing before power is turned off,
otherwise you risk sustaining an electric shock yourself.
• Separate the person as quickly as possible from the electric power source
as follows:
--
Switch off the equipment.
--
Unplug or disconnect the mains cable.
• Move the person away from the power source by using dry insulating
material (such as wood or plastic).
• If the person is unconscious:
--
Check their pulse and reanimate if their respiration is poor.
--
Lay the body down and turn it to one side. Call for a doctor immediately.
• Having sustained an electric shock, Always consult a doctor.
page 10 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 2: Legal issues & facts
Updates
DirectOut products are continually in development, and therefore the information
in this manual may be superseded by new releases. To access the latest
documentation, please visit the DirectOut website:
www.directout.eu.
WARNING!
No compensation can be claimed for damages caused by operation of this unit
other than for the intended use described above. Consecutive damages are also
excluded explicitly. The general terms and conditions of business of DirectOut
GmbH are applied.
Conditions of Warranty
This unit has been designed and examined carefully by the manufacturer and
complies with actual norms and directives.
Warranty is granted by DirectOut GmbH over the period of two years for all
components that are essential for proper and intended operation of the device. The
date of purchase is applied for this period.
Consumable parts (e.g. battery) are excluded from warranty claims.
WARNING!
All claims of warranty will expire once the device has been opened or modified, or
if instructions and warnings were ignored.
For warranty claims please contact the dealer where your device was acquired.
Intended Operation
M.1K2 is designed for distribution of MADI signals (AES10) and routing of serial
data (RS-232 and RS-422/485) and MIDI data.
page 11 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 2: Legal issues & facts
Conformity & Certificates
CE
This device complies with the basic requests of applicable EU guidelines. The
appropriate procedure for approval has been carried out.
RoHS
(Restriction of the use of certain Hazardous Substances)
This device was constructed fulfilling the directive on the restriction of the use of
certain hazardous substances in electrical and electronic equipment 2002/95/EC.
WEEE
(Directive on Waste Electrical and Electronic Equipment)
Due to the directive 2002/96/EC for waste disposal this device must be recycled.
For correct recycling please dispatch the device to:
DirectOut GmbH,
Leipziger Str. 32
09648 Mittweida
Germany
Only stamped parcels will be accepted!
WEEE-Reg.-No. DE 64879540
Contact
DirectOut GmbH, Leipziger Str. 32, 09648 Mittweida, Germany
Phone: +49 (0)3727 5665-100 // Fax: +49 (0)3727 5665-101
www.directout.eu
page 12 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 2: Legal issues & facts
Contents
The contents of your M.1K2 package should include:
• 1 x M.1K2 (19’’, 2 RU)
• 2 x power chord
• 2 x fixing unit for power plug
• 1 x Hardware Guide
To complete the delivery please download from the M.1K2 product page on the
DirectOut website (www.directout.eu):
• USB Serial driver
• latest firmware
Three different types of I/O modules are available:
• BNC coaxial
• SC optical (single-mode or multi-mode or mixed)
• SFP (empty cage, modules not included in delivery)
NOTE!
Check the I/O configuration of your device before proceeding with the installation.
page 13 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 3: Installation
Retain the protective cap if the optical port is unused. This will protect against
soiling which can lead to malfunction.
Avoid damage from condensation by waiting for the device to adapt to the
environmental temperature. Proper operation can only be guaranteed between
temperatures of 5º C and 45º C and a maximum relative humidity of 80%, non-
condensing.
Ensure that the unit has suffi cient air circulation for cooling.
CHAPTER 3: Installation
Installing the Device
1. Open the packaging and check that the contents have been delivered
complete and undamaged.
2. Fix the device in a 19’’ frame with four screws, or place it on a non-slip
horizontal surface.
WARNING!
Do not cover the fan outlets and the slots at the sides of the device!
Do not block the fans by putting objects through the protective grid!
3. Remove the protective cap from the optical MADI port(s) before use.
NOTE!
page 14 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 3: Installation
4. Using the power cord provided connect the PSU to a matching power supply:
WARNING!
This device must be connected to the mains using the three-cord power leads
supplied with the system. Only supply the voltages and signals indicated (84 V –
264 V).
5. Turn on the power switch and check the status of the PSU leds on the front
panel:
6. Network integration of the controller (online wizard for initial setup of the
network connection) - see „Network integration“ on page 16.
7. Check if the latest fi rmware is installed on the device. It is highly
recommended to use the latest version.
To check the fi rmware version, open the GUI in a browser and go to ‘Misc -
Version - System Information’.
NOTE!
For help with the fi rmware update procedure see „Appendix E - Firmware Update
Instruction“ on page 32.
page 15 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 3: Installation
Use the DirectOut Release Map to match your DirectOut device with the latest
firmware or software release.
Link: http://www.directout.eu/upload/dokumente/dotec_release_map.pdf
Keep any packaging in order to protect the device should it need to be dispatched
for service.
8. Optional: Connect a USB cable to the USB port for use of the virtual com
port. This requires the USB Serial driver (Windows) being installed first. The
driver is available from the product page at www.directout.eu.
NOTE!
For help with the USB driver installation see „Appendix F - USB Serial Driver
Installation“ on page 36.
TIP!
TIP!
page 16 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 3: Installation
Network integration
To set up your DirectOut M.1K2 initially (or after a reset) you need a working IP
connection with the controller of the device. M.1K2 is delivered with a fixed IP
address (10.0.0.24). So first you will have to change the network settings of your
computer to setup the IP connection. An online wizard will guide through all
necessary steps then.
NOTE!
For some basics about networking see page 30.
Requirements
• computer with ethernet port - access privileges to network settings required
• standard network cable (e.g. CAT5)
Installation
1. Connect M.1K2 with your computer using a standard network cable (e.g.
CAT5).
WARNING!
The network interface does not comply the requirements of IEEE 802.3af or IEEE
802.3at (aka ‘PoE - power over ethernet’). Connecting to an PoE infrastructure may
damage the device.
2. Go to to the network settings of your operating system
--
Mac OS X: System settings - Network - Ethernet *
--
Windows Control panel - Network and Internet - Network and
Sharing Center - Manage network connections **
* Link:
https://support.apple.com/kb/PH21632?viewlocale=en_US&locale=de_DE
** Link:
http://windows.microsoft.com/en-us/windows/change-tcp-ip-
settings#1TC=windows-7
NOTE!
It is recommended that you store your original network settings before modifying
them.
page 17 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 3: Installation
3. Change IP address setting to manual if set to DHCP and enter:
--
IP address: 10.0.0.20
--
subnet mask: 255.255.255.0
4. Open an internet browser (e.g. Chrome, Firefox) and enter http://10.0.0.24
to open the GUI of the controller. The online wizard will open automatically
and guide you through all necessary steps.
NOTE!
Following you may want to restore the network settings of your computer to the
original values.
5. After setup log in and check the firmware version (go to ‘Misc -Version-
System Information’). If a newer firmware is available, go to ‘Configuration-
Device-Firmware Update’ and perform a firmware update.
The latest version of the firmware is available on the M.1K2 product page at
www.directout.eu.
page 18 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 4: Operation
The green LEDs (PSU 1 & PSU 2) indicate that a working power supply is
connected to the power supply unit. Note that an unlit LED does not guarantee
that the device is free of voltage. To ensure that the device is completely
disconnected from mains voltage, the power chords must be disconnected.
CHAPTER 4: Operation
Introduction
This chapter describes the basic operation of the device.
Global Control
The control on the right of the front panel indicates the power supply. Power
switches are on the back panel:
PSU 1 & PSU 2 (rear)
2 Switches
Enable / disable power supply.
PSU 1 & PSU 2 (rear)
C13 socket
Connect the power supply here (84 - 264 V AC).
PSU 1 & PSU 2 (front)
2 LEDs (green): indicate the status of both
power supply units
LED OFF
= Power supply inactive
LED ON
= Power supply active
LED blinking
4 times per second = The power supply was active,
and is now inactive. Whether
this is a fault state depends
on the circumstances.
If both PSU LEDs are blinking and the fan is blowing at full speed, the FPGA is
being programmed. This only happens during reboot after an update.
NOTE!
page 19 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 4: Operation
Device State & RESET
As most of the system information is available in the GUI (or a telnet shell) only,
the basic system state is indicated by the led ‘STATE’.
If the device can’t be reached via network an emergency recovery may be
executed using the RESET button. See „Appendix A - Emergency recovery“ on
page 26.
STATE
LED (green) indicates current system state.
LED ON
= controller is idle
(normal operation)
LED “heartbeat”
= controller is idle
(normal operation)
LED blinking
once per second
= factory default network
setting is active
LED blinking
4 times per second = unsaved confi guration data,
device will return to idle state
after saving to the fl ash
memory.
RESET
Push button
Press and hold > 5 seconds for emergency recovery.
NOTE!
The behaviour of the led ‘STATE‘ may be confi gured in the GUI. Please consult the
offl ine help available from our website or use the online help within the GUI.
page 20 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 4: Operation
User data (Serial, MIDI, GPO)
For remote application and signaling purposes there are connection possibilities for
RS 232 / 422 / 485, MIDI and General Purpose Output (GPO).
Serial signals can be routed either by using user bits* of a MADI frame. 4 GPOs
can be triggered manually or automatically by a system event.
SERIAL 232
DSUB-9 socket (male)
Connect RS-232 signal here.
Observe the correct pin assignment**. For safe
operation lock the connection using the jack bolts.
SERIAL 4xx
DSUB-9 socket (female)
Connect RS-422 or RS-485 signal here.
Observe the correct pin assignment**. For safe
operation lock the connection using the jack bolts.
GPO
DSUB-9 socket (female)
Connect GPO signals here.
Observe the correct pin assignment**. For safe
operation lock the connection using the jack bolts.
MIDI OUT
DIN socket
Connect MIDI output signal here.
MIDI IN
DIN socket
Connect MIDI input signal here.
* Tunneling of MIDI signals is compatible to the transmission method used by all
other DirectOut devices and RME products. Tunneling of RS-232 and RS-4xx data
is compatible to the transmission method used by Studer / Soundcraft.
** The pin assignment is described in „Appendix B - DSUB-9 Pin assignments“ on
page 27
The USB port may be used as serial port too -
see „Remote Operation“ on page 22.
page 21 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 4: Operation
Clocking
M.1K2 may use a variety of clock sources:
• internal (44.1 kHz / 48 kHz)
• word clock
• video (PAL / NTSC)
• a specifi c MADI input port
The system may be operated with one clock source only or may use different clock
sources at a time (PolySync™). That means that one can use a bunch of ports with
clock source ‘A’ while another portion is clocked by clock source ‘B’.
The selected clock source is output at both word clock outputs.
VIDEO IN
1 x BNC socket (coaxial)
Connect video reference signal here (black burst
PAL or NTSC; the video standard is detected
automatically).
WCK IN
1 x BNC socket (coaxial)
Connect word clock signal here.
WCK OUT
2 x BNC socket (coaxial)
Connect here to receive word clock output signal.
The left socket provides the base rate only (44.1 / 48
kHz). The right socket outputs full sample rate word
clock - also multiples of the base rate (2 FS / 4 FS).
75 Ω
LED (yellow): indicates the termination
status of word clock and video input.
LED ON
= termination enabled
LED OFF = termination disabled
SYNC (VIDEO IN)
LED (green): indicates the sync status of the
incoming video signal
LED ON
= signal locked
LED OFF
= no signal present
LED fl ashing = signal present, not locked
SYNC (WCK IN)
LED (green): indicates the sync status of the
incoming word clock signal
LED ON
= signal locked
LED OFF
= no signal present
LED fl ashing = signal present, not locked
page 22 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 4: Operation
Remote Operation
M.1K2 may be controlled via an ethernet connection or serial data input.
NETWORK
RJ45 socket
Connection for ethernet control
Requires a standard CAT5 cable for connection with
ethernet network (10 / 100 MBit/s).
USB
USB socket (2.0)
USB connection for virtual serial port. Requires a
standard USB cable (Type B).
NOTE!
To use the USB port as virtual serial port a serial USB driver (for Windows®) has
to be installed on the computer fi rst. The driver is available on the M.1K2 product
page at www.directout.eu. See „Appendix F - USB Serial Driver Installation“ on
page 36.
page 23 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 5: Troubleshooting and Maintenance
Troubleshooting
To identify a possible defect with the device please consult the following table.
If the fault cannot be resolved using these instructions, please contact your local
DirectOut representative or visit support.directout.eu.
Maintenance
To clean the device, use a soft, dry cloth. To protect the surface, avoid using
cleaning agents.
The device should be disconnected from the power supply during the cleaning
process.
CHAPTER 5: Troubleshooting and Maintenance
Issue
Possible reason
Solution
Device doesn’t
work.
Power supply is
broken.
Check that the power supply switch
is on, that the device is connected to
the power supply and that the socket
is working. Defective fuses must be
exchanged by qualified service personal
only.
Optical port does
not work.
Optic is dirty.
Use an air supply to carefully remove any
dust.
Never use objects for cleaning.
No signal at the
output port.
Connections (input /
output) are mixed up.
Check the connections and change the
cables if necessary.
Check the routing matrix.
No signal at the
output port.
Signal cable defective.
Exchange the signal cable.
MADI signal at the
input is not stable.
Signal source is
defective
or
bad signal condition
(Jitter > 1 ns) - e.g.
due to exceeded
length or bad
screening attenuation
of signal cable.
Change the source
or
use appropriate cables.
Clicks in the
audiosignal.
Input source is not
in sync with clock
master of the box.
Check the status of input led and check
clock setting of the connected device.
NOTE!
page 24 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 6: Technical Data
CHAPTER 6: Technical Data
Dimensions
• Width 19’’ (483 mm)
• Height 2 RU (89 mm)
• Depth 10’’ (254 mm)
Weight
• about 4 kg
Power Consumption
• typical 0.2 A (@84 V) up to max. 0.1 A (@264 V)
• max. 0.4 A (@84 V) up to max. 0.2 A (@264 V)
Power Supply
• 84 V - 264 V AC / 47 Hz - 63 Hz / Safety class 1
Fuses
• Fuse 250 V - 2 A (slow-blow) – 2 fuses per power supply
Environmental Conditions
• Operating temperature +5°C up to +45°C
• Relative humidity: 10% - 80%, non condensing
MADI Port - coaxial
• 16 x BNC socket (8 x input / 8 x output)
• Impedance: 75 Ω
• 0.3 V up to 0.6 V (peak to peak)
MADI Port - optical SC
• 8 x SC socket FDDI (input / output)
• ISO/IEC 9314-3
• Wave length: 1310 nm
• Multi mode 62.5/125 µm or 50/125 µm
• optional: single mode 9/125 µm
MADI Port - SFP
• 8 x SFP cage without module
• Wave length: depending on used transceiver (typical 1310 nm)
• Multi mode 62.5/125 µm or 50/125 µm
• Single mode 9/125 µm
Sample Rate
•
30 kHz - 50 kHz @ 1 FS
•
60 kHz - 100 kHz @ 2 FS
• 120 kHz - 200 kHz @ 4 FS
page 25 of 44
M.1k2 Hardware Guide - Version 1.3
CHAPTER 6: Technical Data
MADI Format (I/O)
• 48k Frame, 96k Frame
• 56 channel, 64 channel
• S/MUX 2/4
Word Clock
• 1 x BNC socket (75 Ω impedance) - input
• 2 x BNC socket (75 Ω impedance) - output
• Termination 75 Ω switchable
Video
• 1 x BNC socket (75 Ω impedance) - input
• Termination 75 Ω switchable
MIDI
• 2 x DIN socket (input / output)
Serial Communication
• RS-232
• RS-422 / RS-485
General Purpose Output (GPO)
• 4 x Avago ASSR-1411-S optical MOSFETs up to 60 V / 600 mA switching
(AC or DC)
Ethernet
• RJ45 socket (10/100 Mbit/s full duplex - auto negotiation),
• IEEE 802.3i/u
USB
• 1 x USB 2.0 socket (Type B)
• may be used as virtual serial port (Windows® only)
Cable Specifications
• coaxial cable - impedance 75 Ω, screening attenuation better than 85 dB
page 26 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix A - Emergency recovery
Appendix A - Emergency recovery
There is one static network confi guration which you cannot modify, it is called
‘Factory preset’. If you somehow managed to create a dysfunctional set of network
settings or cannot reach the device for other reasons, you can always return to the
factory preset via the front panel.
Procedure: Press the RESET button on the front panel for about 5 seconds. As
soon as you press the button, it will start fl ashing rapidly. When it stops fl ashing,
the factory preset has been activated. You can then access the device via the initial
IP address (10.0.0.24).
The LED STATE indicates the operating condition:
LED
Operating Condition
Constant on
The controller is idle (normal operation).
Heartbeat
The controller is idle (normal operation).
Blinking once per second
The factory default network settings are active.
This state should only be active when confi guring
the device for the fi rst time, or after the RESET
button has been pressed.
You can confi gure the network in ‘Confi guration-
Device-Network’ settings.
Blinking 4 times per second
There is unsaved confi guration data. After the
changes have been written safely to the fl ash
memory, the state LED returns to the idle state.
NOTE!
This procedure will only reset the IP confi guration. All other device settings (e.g.
routing, channel labels, clocking, ...) will remain unchanged.
page 27 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix B - DSUB-9 Pin assignments
Appendix B - DSUB-9 Pin assignments
RS-232
The RS-232 port handles bitrates of 9600, 19200, 38400 and 115200 bps without
RTS/CTS support.
PIN
Signal
2
RX
3
TX
5
GND
RS-4xx
The RS-4xx port can be confi gured to handle RS-422 or RS-485 signals and bitrates
of 9600, 19200, 38400 and 115200 bps.
PIN
Signal
1
GND
2
RS-422 RX+
3
RS-422 TX- / RS-485 RX-
4
GND
5
6
GND
7
RS-422 RX-
8
RS-422 TX+ / RS-485 RX+
9
GPO
M.1K2 has four GPOs which can be switched manually or triggered by certain
events. Ground-free switching is performed by Avago ASSR-1411-S optical
MOSFETs, which can switch up to 60 V, 0.6 A AC or DC.
PIN
Signal
1/6
GPO 1
2/7
GPO 2
3/8
GPO 3
4/9
GPO 4
jack - male
jack - female
jack - female
1
2
3
4
5
9
8
7
6
1
2
3
4
5
9
8
7
6
1
2
3
4
5
9
8
7
6
page 28 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix C - Installing / Replacing I/O modules
Appendix C - Installing / Replacing I/O modules
Three different modules are available to fit in to the two slots of M.1K2. If
necessary the modules may be replaced or swapped executing the following
steps.
Requirements:
• I/O module
• Screwdriver (Phillips 1)
The installation of the module does not require to open the device. The module is
inserted at the front side of the device.
ESD (Electrostatic Discharge)
The components of the module may be damaged by electrostatic discharge.
Observe the precautions (e.g. the use of an antistatic wrist strap) for the handling
of parts that are susceptible to electrical discharge.
1. Remove all cables from the device.
2. Loose both phillips screws at the left and right side of the blind plate using
the screwdriver.
3. Remove the blind plate or module at the front side of the device.
TIP!
As the device must not be operated with an opening, you may want to keep the
blind plate in case of deinstallation of the module.
4. Unpack the module from the protective bag. Touch the module at the metal
plate only.
5. Insert the module with the pins ahead into the guide rails and put it softly
into the device. To connect the pins of the module with the backplane of the
device smart pressure is needed finally.
6. Fix the metal plate of the module screwing both screws in the front panel.
page 29 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix C - Installing / Replacing I/O modules
Modules
BNC - Module, coaxial
SC - Module, optical
SFP - Module, empty cages
page 30 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix D - How to - Network
Appendix D - How to - Network
The following guide aims to familiarize with basic information to setup a TCP/IP
network. Some terms and techniques are explained to conduct you through the
first steps.
Terms
IP Address - Address of a device within your local network. Must be unique.
Example: 192.168.74.15 or 10.0.0.24
Gateway - Address of the network router. When connecting only two devices
‘peer to peer’, use the ip address of one device if it is needed to be declared.
Example: 192.168.74.1 or 10.0.0.20
DNS - Address of Domain Name Server. If you are using a network router with
internet access the IP address of the router can be used here. One may define
a second DNS for use once the first one fails. Example: 192.168.74.1 (same as
gateway) or 8.8.8.8 (Google DNS server) or other…
Network router - device that handles the traffic within a network. Often used
with integrated ADSL modem. Not necessary to setup a peer to peer connection
between two devices only. Has IP address (Gateway).
DHCP - Dynamic host configuration protocol. It is used to assign address
parameters automatically to devices that are connected to a DHCP server. Network
router often act as DHCP server.
NOTE!
You can use the device‘s MAC address (written on the back panel of the M.1K2) in
order to find out the IP address that has been assigned to it by the DHCP server.
Network Mask - a bitmask that splits the network into two parts
• Network contingent: fixed - identical for all devices
• Device contingent: variable - unique for each device, defines the number of
available addresses within the network
The network mask (like the IP address) contains of 32 bits and is often expressed
by decimals. The result of two binary calculations defines both contingents.
Example:
IP address
1100’0000 1010’1000 0100’1010 0000’1111
192.168.74.15
AND
network mask
1111’1111 1111’1111 1111’1111 0000’0000
255.255.255.0
network contingent
1100’0000 1010’1000 0100’1010 0000’0000
192.168.74.0
IP address
1100’0000 1010’1000 0100’1010 0000’1111
192.168.74.15
NAND
network mask
0000’0000 0000’0000 0000’0000 1111’1111
255.255.255.0
device contingent
0000’0000 0000’0000 0000’0000 0000’1111
0.0.0.15
page 31 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix D - How to - Network
24 bits are already set for the network contingent, leaving 8 bits
(28 = 256) left for the variable device contingent. The smallest address
192.168.74.0 defi nes the network and the biggest address 192.168.74.255
is reserved. So there are 254 different IP addresses available (192.168.74.1 -
192.168.74.254).
In a network environment each device (computer, printer, M.1K2…) needs
its own and unique IP address. This can be achieved by a manual setup or by
using a DHCP server within a network.
The use of a DHCP may ease up the administration of a network. However,
if fi xed and known addresses are a need, it is helpful to set up a network
manually.
Example 1 - Peer to Peer
The devices are connected directly. This setup may be used at initial
operation of the M.1K2.
Example 2 - Network with router
Three devices are connected by a router that handles the traffi c within the
network. Each device has its own .
IP Adress: 10.0.0.20
Network Mask: 255.255.255.0
Gateway: 10.0.0.20
DNS: 8.8.8.8
IP Adress: 10.0.0.24
Network Mask: 255.255.255.0
Gateway: 10.0.0.20
DNS 1: 8.8.8.8
DNS 2: 8.8.8.8
IP Adress: 192.168.74.2
Network Mask: 255.255.255.0
Gateway: 192.168.74.1
DNS: 8.8.8.8
IP Adress: 192.168.74.15
Network Mask: 255.255.255.0
Gateway: 192.168.74.1
DNS 1: 192.168.74.1
DNS 2: 8.8.8.8
IP Adress: 192.168.74.5
Network Mask: 255.255.255.0
Gateway: 192.168.74.1
DNS: 8.8.8.8
IP Adress: 192.168.74.1
Network Mask: 255.255.255.0
Gateway: 192.168.74.1
DNS: 8.8.8.8
page 32 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix E - Firmware Update Instruction
Appendix E - Firmware Update Instruction
This instruction describes the firmware update procedure for the M.1K2.
Requirements:
• M.1K2
• Network access to the M.1K2
• Access to the admin account of the controller
NOTE!
It is recommended that you backup the configuration data of the device
(Configuration - Backup/Restore in the GUI) before performing the firmware update
procedure.
Installation
1. Download the update file (‘M.1K2 Firmware’) from the product page at
www.directout.eu
2. Open an internet browser (e.g. Chrome, Firefox) and open the GUI of the
controller. Go to ‘Configuration - Device’.
3. Go to ‘Firmware Update’ by expanding the dialog (‘+’ top right corner).
4. Select ‘Choose File’ and browse to the downloaded update file
(file extension ‘.1k2’).
page 34 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix E - Firmware Update Instruction
5. Select ‘Begin update’. The fi le will be uploaded, checked and detailed update
information will be shown after a few seconds. Please read this carefully!
6. Confi rm the update with ‘Begin update!’.
The update process may take several minutes. While updating the device
is not accessible and audio will not be processed. After update the device is
rebooted automatically. The network confi guration remains unchanged.
7. After the update you need to log in again. You may check the version of the
fi rmware by navigating to ‘Misc - Version’.
page 35 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix E - Firmware Update Instruction
NOTE!
It is strongly recommended to clear the browser cache after the update to ensure
proper browser behaviour at next login.
page 36 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix F - USB Serial Driver Installation
Appendix F - USB Serial Driver Installation
This instruction describes the procedure of installing the USB serial driver on
Windows®.
Requirements
• M.1K2
• USB cable (Type B)
• Windows® PC (supported operating systems: XP, Vista,7, 8, 10)
• USB serial driver from M.1K2 product page at www.directout.eu
Driver details
This driver (m1k2-black-usb.inf) provides access to the virtual COM port. The driver
works with the M.1K2 - black panel version only.
Installation
1. Unpack the driver fi les into a temp directory.
2. Connect the USB port of M.1K2 to an USB port of your computer.
3. Switch the device on.
When connecting the device Windows will try to download driver fi les from the
Windows Update server. As the DirectOut drivers are not distributed through the
Microsoft Update Service this attempt will fail.
4. Open the ‘Device Manager’. It will show an unknown device called ‘M.1K2’.
page 37 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix F - USB Serial Driver Installation
5. Right click on ‘M.1K2’ and select ‘Update Driver Software…’.
6. Browse to the location where you downloaded and unpacked the driver and
select the folder.
7. Click’Next’. A security warning will occur.
8. Click ‘Install…’ to continue.
page 38 of 44
M.1k2 Hardware Guide - Version 1.3
Appendix F - USB Serial Driver Installation
After a successful installation the ‚Device Manager‘ will show a ‚M.1K2 Serial Port‘.
The port number is assigned by Windows automatically.
Deinstallation
To uninstall the driver the device must be connected to the computer.
To remove the USB Serial driver from your system, please execute the following
instructions:
1. Open the ‘Device Manager’.
2. Select the node ‘Ports (COM & LPT)’ and decollapse it.
3. Right click on ‘M.1K2 Serial Port’
4. Select Uninstall
5. Check the ‘Delete the driver software for this device’ fi eld and click ‘OK’.
page 39 of 44
M.1k2 Hardware Guide - Version 1.3
Index
Index
C
Cable Specifications................................. 25
Conformity & Certificates
CE......................................................... 11
RoHS.................................................... 11
WEEE................................................... 11
Contact..................................................... 11
Contents................................................... 12
Conventions................................................ 5
D
Defective Parts/Modules............................ 8
Dimensions............................................... 24
E
Emergency recovery................................. 26
Environmental Conditions......................... 13
F
Feature Summary....................................... 7
Firmware Update...................................... 32
First Aid...................................................... 9
Fuses........................................................ 24
G
GPO
Pin assignments................................... 27
I
Intended Operation................................... 10
M
Modules.................................................... 29
Installing/Replacing............................... 28
N
Network.................................................... 30
DHCP.................................................... 30
DNS...................................................... 30
Gateway............................................... 30
IP Adress.............................................. 30
Network Mask...................................... 30
Network settings
OS X®.................................................. 16
Windows®........................................... 16
P
Peer to Peer.............................................. 31
Pin assignments....................................... 27
R
Reset........................................................ 19
RS-232...................................................... 20
Pin assignments................................... 27
RS-422/485............................................... 20
Pin assignments................................... 27
S
Support..................................................... 23
T
Troubleshooting. 23 See Emergency recovery
U
Updates.................................................... 10
W
Warranty................................................... 10
WEEE See Conformity & Certificates: WEEE
Leipziger Strasse 32
09648 Mittweida
Germany