Text of the manual

The GS2065 provides primary or backup GSM/GPRS communication for the PC9155 2-way wireless security

suite Specifications: Dimensions : 3.937"x5.875"x0.625" (100mmx150mmx15mm) Weight : 68 g Input Voltage : 10 to 13.8 V (from the PC-Link header) Current Draw : 100 mA at 12V (400 mA during the GSM transmission) Operating Environment : 40 to 104 F (5 to 40 C) Compatible Receivers: Sur-Gard System I Receiver: version 1.10 and higher Sur-Gard System II Receiver: version 2.00 and higher Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver) Features: Back up and primary GSM/GPRS alarm communication Panel remote uploading/downloading support via GSM/GPRS Supervision heartbeats via GSM/GPRS 128-bit AES encryption over GSM/GPRS Full event reporting SIA format PC-Link connection SIM card included Signal strength and trouble display Activating and initializing through Connect 24 Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz

The TL265GS is an Internet and GSM/GPRS Dual-Path alarm communicator for the PC9155 2-way

wireless security suite Specifications: Dimensions : 3.937"x5.875"x0.75" (100mmx150mmx18mm) Weight : 78 g Input Voltage : 10 to 13.8 V (from the PC-Link header) Current Draw : 100 mA at 12V (400 mA during the GSM transmission) Operating Environment : 40 to 104 F (5 to 40 C) Compatible Receivers: Sur-Gard System I Receiver: version 1.10 and higher Sur-Gard System II Receiver: version 2.00 and higher Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver) Features: Fully redundant Internet and GSM/GPRS dual-path alarm communication Integrated call routing Panel remote uploading/downloading support via GSM/GPRS and Internet Supervision heartbeats via GSM/GPRS and Internet 128-bit AES encryption via GSM/GPRS and Internet Full event reporting SIA format PC-Link connection SIM card included Signal strength and trouble display Activating and initializing through Connect 24 Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz

BEFORE YOU BEGIN

Have the following ready before installation: Control panel backup battery Battery connection harness Batteries for WT5500 2-way wireless keypad Screwdriver Prior to installing a GS2065 and TL265GS, contact your monitoring station to determine if it is a master reseller or visit www.connect24.com and become an authorized dealer. In both instances, you will acquire a Profile Number, Installer ID Number and an Installer Password. PLEASE NOTE: You need to activate the SIM card and initialize the communicator 24 HOURS BEFORE INSTALLATION (Steps 1). Summary of Installation Steps Step 1 – Initialize an account via Connect 24 Website (www.connect24.com) Step 2 – Install and wire the communicator to the control panel (on-site) Step 3 – Load the programming and test for best signal strength location Step 4 – Program communication options on the control panel via keypad Step 5 – Test communicator

Step 1 – Initialize an account via Connect 24 Website (www.connect24.com)

Login to Connect 24 website by using Installer ID and Password and initialize an account Select Profile Number Select Product Module Enter SIM card number Enter DNIS number (if necessary) Enter Account Code Select Supervisory Type (if necessary) Enable DHCP (if necessary) Enter IP Address (TL260GS/TL265GS only) Enter Subnet Mask Address (TL260GS/TL265GS only) Enter Gateway Address (TL260GS/TL265GS only) Select Rate Plan Confirm information and submit activation application

Step 1 – 4

Enter DNIS number (if necessary) Enter Account Code Select Supervisory Type (if necessary) Enable DHCP (if necessary) Note: If DHCP is not selected, manual entries of the IP Address, Subnet Mask Address and Gateway Address are required (next page). Enter DNIS Enter Account Code Select Supervisory Type DHCP Option

Step 1 – 5 (only available if DHCP is not selected)

Enter IP Address (TL265GS only) Enter Subnet Mask Address (TL265GS only) Enter Gateway Address (TL265GS only) IP Address Subnet Mask Gateway

Step 2 – Install and wire the communicator to the control panel (on-site)

GS2065/TL265GS: See details in product manual for PC9155 control panel

Step 3 – Load the programming and test for best signal strength location

Ensure the SIM card is inserted Power up the control panel The communicator will be programmed by loading the pre-programmed configuration from Connect 24 automatically Check Green LEDs. You must achieve full or medium signal strength. See details in product manual If signal strength is poor, must relocate the control panel or use an external extension antenna kits

Step 4 – Program communication options on the control panel via keypad

GS2065/TL265GS with PC9155 control panel o [301], [302], [303], [305] Program Communication Path • DCAA - Internal (Ethernet 1, Ethernet 2, GPRS 1, GPRS 2) • DCBB - Ethernet Receiver 1 • DCCC - Ethernet Receiver 2 (backup) • DCDD - GPRS Receiver 1 • DCEE - GPRS Receiver 2 (backup) o [350] option: Program Communication Format (Communicator) • (If Option [301] (above) is set to DCAA, Option [350] must be set to SIA, sub-option 5) o [351] to [376] options: Program Call Direction o [382] option: Enable T-LINK Interface (Option [5]) o [383] option: Program Back up Communication o [167] option: Enable Communication Wait For ACK (Set to 60 seconds) o [401] option: Enable DLS Session Through GPRS or Ethernet (Option [1])

Step 5 – Test communicator

1. Disconnect incoming phone line from TIP and RING on the control panel 2. Verify that LED 2 is on, this indicate that the unit is active 3. Create an alarm transmission 4. Verify alarm transmission by calling monitoring station 5. Re-connect the phone line, if necessary For back-up communication applications, perform steps 1 to 5 For primary communication applications, perform steps 3 and 4 only

Communicator Controlled Call Routing

– Backup (dual-path) – Redundant (dual-path) Required Programming Panel Sections [301], [302],[303] and [305] •Any of them could be programmed as DCAA Communicator Sections [005] Option [4] ‐ Primary and backup path [ON]: GPRS path primary, Ethernet path backup [OFF]: Ethernet path primary, GPRS path backup Option [5] ‐ Redundant between GPRS path and Ethernet path [OFF]: Disable redundancy [ON]: Enable redundancy Backup Mode 1: Ethernet Primary, 4 Receivers Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 GPRS Receiver 2 IP Receiver* 1 IP Receiver 2 IP Receiver 3 IP Receiver 4 Tx 2 failed, TX3 TX 1 Tx 3 failed, Tx4 Tx 1 failed, Tx2

Backup Mode 2:

Ethernet Primary, 2 Receivers Backup Mode 3: GPRS Primary, 4 Receivers Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 GPRS Receiver 2 IP Receiver 1 IP Receiver 2 IP Receiver 3 IP Receiver 4 Tx 2 failed, TX3 TX 1 Tx 3 failed, Tx4 Tx 1 failed, Tx2 Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 GPRS Receiver 2 IP Receiver 1 IP Receiver 2 TX 1 Tx 3 failed, Tx4 Tx 1 failed, Tx2 Tx 2 failed, TX3

Backup Mode 4:

GPRS Primary, 2 Receivers Redundant Mode 1: 4 Receivers – (Redundancy between GSM/GPRS path and Ethernet/Internet path) Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 GPRS Receiver 2 IP Receiver 1 IP Receiver 2 IP Receiver 3 IP Receiver 4 TX1, GPRS path TX 1, Ethernet path TX 1 failed, TX 2 via GPRS path TX1 failed, TX 2 via Ethernet path Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 GPRS Receiver 2 IP Receiver 1 IP Receiver 2 TX 1 Tx 3 failed, Tx4 Tx 1 failed, Tx2 Tx 2 failed, TX3

Redundant Mode 2: 2 Receivers

– (Redundancy between GSM/GPRS path and Ethernet/Internet path) Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 GPRS Receiver 2 IP Receiver 1 IP Receiver 2 TX1, GPRS path TX1 failed, TX 2 via Ethernet path TX 1 failed, TX 2 via GPRS path TX 1, Ethernet path

PC9155 Panel Controlled Call Routing

Backup (triple‐path) Panel section [383] – Options [2],[3] and [4] enabled Panel section [380], Option [6] disabled Redundant (triple‐path) Panel sections [351] – [376] Options enabled Alternate (triple‐path) Panel section [380] – Option [6] enabled Required Programming Panel Sections [301], [302],[303] and [305] • Phone #: Phone number of the receiver • DCBB: Ethernet Receiver 1 • DCCC: Ethernet Receiver 2 • DCDD: GPRS Receiver 1 • DCEE: GPRS Receiver 2 PC9155 Panel Controlled Call Routing –Backup: Panel Section [383] – Options [2],[3] and [4] enabled DC DD [305] DC C C [303] DC BB [302] 1‐800‐xxxxxxx [301] DC DD [305] DC C C [303] DC BB [302] 1‐800‐xxxxxxx [301] Phone Line Receiver 1 IP Receiver 1 IP Receiver 2 IP Receiver 3 Phone Line path Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 TX 1 Tx 1 5 failures, Tx2 Tx 2 5 failures, Tx3 Tx 3 5 failures, Tx4 Example

PC9155 Panel Controlled Call Routing

–Redundant: Panel Sections [351] – [376] Options enabled PC9155 Panel Controlled Call Routing –Alternate: Panel section [380] – Option [6] enabled DC DD [305] DC C C [303] DC BB [302] 1‐800‐xxxxxxx [301] DC DD [305] DC C C [303] DC BB [302] 1‐800‐xxxxxxx [301] Phone Line Receiver 1 IP Receiver 1 IP Receiver 2 IP Receiver 3 Phone Line path Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 TX 1 Tx 1 1 failure, Tx2 Tx 2 1 failure, Tx3 Tx 3 1 failure, Tx4 5 rounds total Example DC DD [305] DC C C [303] DC BB [302] 1‐800‐xxxxxxx [301] DC DD [305] DC C C [303] DC BB [302] 1‐800‐xxxxxxx [301] Phone Line Receiver 1 IP Receiver 2 IP Receiver 3 IP Receiver 4 Phone Line path Ethernet Receiver 1 Ethernet Receiver 2 GPRS Receiver 1 TX 1 TX 1 TX 1 TX 1 Example