FEATURES
• All products are UL approved.
• All products offer three-way isolation,
2000-V input/output.
• All products operate from -40 to +185°F
(-40 to +85°C).
• The Industrial DIN Rail Converter
converts unbalanced half- or full duplex
RS-232 signals to balanced full duplex
RS-422 or 2-wire half- or 4-wire full
duplex RS-485.
• Both Industrial DIN Rail Repeaters
boost your data signals, feature optical
isolation, and include 600 W of surge
suppression.
• The Industrial DIN Rail Fiber Driver
enables any two async serial devices
to communicate half- or full duplex
over two multimode ST fibers at
distances up to 2.5 miles (4 km).
Our DIN rail solutions in an industrial setting.
OVERVIEW
Industrial RS-232↔RS-422/RS-485 DIN Rail Converter
• UL® approved.
• Three-way isolation, 2000-V input/output.
• Operates from -40 to +185°F (-40 to +85°C).
• Converts unbalanced half- or full duplex RS-232 signals
to balanced full duplex RS-422 or 2-wire half- or 4-wire
full duplex RS-485.
• Extends communications up to 4000 feet (1219.2 m).
• Features addressing up to 32 nodes.
Industrial RS-422/RS-485 DIN Rail Repeater
• UL approved.
• Three-way isolation, 2000-V input/output.
• Operates from -40 to +185°F (-40 to +85°C).
• Features optical isolation plus 600 W of surge suppression.
• Adds 4000 feet (1219.2 m) and another 32 nodes to an
RS-485 data circuit. Configure one side as RS-422 and the
other side as RS-485 to enable a 4-wire RS-422 device to
communicate with a 2-wire RS-485 device.
Industrial RS-232 DIN Rail Repeater
• UL approved.
• Three-way isolation, 2000-V input/output.
• Operates from -40 to +185°F (-40 to +85°C).
• Features optical isolation plus 600 W of surge suppression.
• Isolates the TD, RD, RTS, and CTS channels.
• Modbus ASCII or RTU compatible.
• Automatic Send Data Control eliminates the need
for driver software.
Industrial DIN Rail RS-232/RS-422/RS-485↔
Fiber Driver
• UL approved.
• Three-way isolation, 2000-V input/output.
• Operates from -40 to +185°F (-40 to +85°C).
• Enables any two async serial devices to communicate
half- or full duplex over two multimode ST fibers at
distances up to 2.5 miles (4 km).
• RS-232 signals are supported up to 115.2 kbps; RS-422
or RS-485 signals are supported up to 460.8 kbps.
Industrial RS-232↔
RS-422/RS-485 DIN Rail
Converter (ICD105A)
Industrial RS-422/RS-485
DIN Rail Repeater
(ICD107A)
DIN Rail RS-422/RS-485
Data-Line Surge Protector
(SPD001A)
Industrial DIN Rail
RS-232/RS-422/RS-485↔
Fiber Drivers (MED101A)
DIN Rail 12-VDC
Power Supply
(PSD100)
DIN Rail 12-VDC
Power Supply
(PSD100)
Time
clocks
Fiber Cable
Conveyor belt
Time clock
Scale
Workstation
Low-Capacitance
Cable (ERN04A)
Low-Capacitance
Cable (ERN04A)
Low-Capacitance
Cable (ERN04A)
Low-Capacitance
Cable (ERN04A)
DB9 Male/Female
Cable (BC00200)
1/22/2007
#26548
724-746-5500
blackbox.com
3 of 3
TECH SPECS
Distance (Maximum) — ICD105A, ICD107A: 4000 ft. (1219.2 m);
ICD108A: 50 ft. (15.2 m);
MED101A: 2.5 mi. (4 km)
Operation — ICD105A: RS-232: Half- or full duplex;
RS-422: Full duplex;
RS-485: 2-wire half-duplex or 4-wire full duplex;
ICD107A: RS-422: Full duplex;
RS-485: 2-wire half-duplex or 4-wire full duplex;
ICD108A: RS-232: Half- or full duplex;
MED101A: RS-232: Half- or full duplex;
RS-422: Full duplex;
RS-485: 2-wire half-duplex or 4-wire full duplex;
Fiber ring: Half-duplex over multimode;
All transmissions are async
Speed — ICD105A: 1200 bps to 115.2 kbps;
2400 bps to 38.4 kbps, switch-selectable;
ICD107A: 2400 bps to 115.2 kbps, switch-selectable;
other rates available up to 460.8 kbps;
ICD108A: Up to 115.2 kbps;
MED101A: RS-232: Up to 115.2 kbps;
RS-422/RS-485: Up to 460.8 kbps
CE Approval — Yes
Connectors — ICD105A: (1) 5-position terminal block, (1) DB9 F (DCE);
ICD107A: (2) 5-position terminal blocks;
ICD108A: (1) DB9 M, (1) DB9 F;
MED101A: (2) 5-position terminal blocks, (1) pair of ST®
Operating Environment — Temperature: -40 to +185°F (-40 to +85°C);
Humidity: Up to 95% noncondensing
Power — +10 to -48 VDC (±20%) or from optional DIN Rail 12-VDC
Power Supply (PSD100)
Size — ICD105A: 4.9"H x 4.1"W x 1.3"D (12.4 x 10.4 x 3.3 cm);
ICD107A: 3.9"H x 2.9"W x 0.9"D (9.9 x 7.4 x 2.3 cm);
ICD108A: 4.9"H x 4.2"W x 1.3"D (12.4 x 10.7 x 3.3 cm);
MED101A: 4.9"H x 4.5"W x 1.3"D (12.4 x 11.4 x 3.3 cm)
1/22/2007
#26548
724-746-5500
blackbox.com
Item
Code
Industrial RS-232↔RS-422/RS-485 DIN Rail Converter ICD105A
Industrial RS-422/RS-485 DIN Rail Repeater
ICD107A
Industrial RS-232 DIN Rail Repeater
ICD108A
Industrial DIN Rail RS-232/RS-422/RS-485↔Fiber Driver
MED101A
For DB9 male/female connections, order…
DB9 Male/Female Cable, 6-ft. (1.8-m)
BC00200
For RS-422 and RS-485 interfaces, order…
Individually Shielded Low-Capacitance Cable—Extra Distance,
PVC Jacket, 4 Conductors (2 Pairs), 2000-ft. (609.6-m)
ERN04A-2000
You may also need…
DIN Rail, 1-m (3.2-ft.)
DR100
DIN Rail DB25 to Terminal Block Adapter
IC980
DIN Rail RS-422/RS-485 Data-Line Surge Protector
SPD001A
To power six converters or repeaters—or four fiber drivers—
order…
DIN Rail 12-VDC Power Supply
PSD100
DIN rail is an industry-standard metal rail, usually installed
inside an electrical enclosure, which serves as a mount for small
electrical devices specially designed for use with DIN rails.
These devices snap right onto the rails, sometimes requiring
a set screw, and are then wired together.
DIN rails are a space-saving way to accommodate com-
ponents. And because DIN rail devices are so easy to install,
replace, maintain, and inspect, this is an exceptionally conven-
ient system that has become very popular in recent years.
A standard DIN rail is 35 mm wide with raised-lip edges,
its dimensions outlined by the Deutsche Institut für Normung,
a German standardization body. Rails are generally available
in aluminum or steel and may be cut for installation.
Depending on the requirements of the mounted components,
the rail may need to be grounded.
Technically Speaking
ICD105A