Easy Access Easy-809 Manual 

Text of the manual

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

2 EU809 User Guide EU809 PROGRAMMING INSTRUCTIONS Enrolling Fingerprint Users Ⅰ Ⅰ Ⅰ Ⅰ Enrolling the master Administrator Press ADD button at the outside unit. When the green LED gives three flashes and one beep is heard, enrollment process starts. When the red scanner light turns red, rest the finger on the scanner and hold it. The scanner light will give three flashes. When the scanner light turns off finally, move the finger away. When one long beep is heard and the green LED turns off, the master administrator is enrolled successfully. The default User ID for the master administrator is 01. Ⅱ Ⅱ Ⅱ Ⅱ Enrolling Administrator 02 Press ADD button. When one beep is heard, the green LED gives three flashes and the scanner light turns red, rest the master administrator’s finger on the scanner and move it away when the scanner light turns off. (If the green LED flashes three times, the mater administrator is verified; if the red LED flashes, the master administrator is rejected. In this case, please repeat the above mentioned steps.) Input User ID 02 from the outside keypad. When one beep is heard, the User ID is entered successfully. Rest the finger on the scanner (scanner light will flash three times) and move it away when the light turns off finally. When one long beep is heard, the administrator is enrolled successfully. If three beeps are heard, and the red LED flashes three times, the administrator enrollment fails. You can enter User ID 03 directly at the outside unit to continue to enroll Administrator 03 as soon as Administrator 02 is enrolled. Ⅲ Ⅲ Ⅲ Ⅲ Enrolling general users Press ADD button. When one beep is heard, the green LED flashes three times and the scanner light turns red, rest the administrator’s finger on the scanner and move it away when the scanner light turns off. (If the green LED flashes three times, the administrator is verified; if the red LED flashes, the administrator is rejected. In this case, please repeat the above mentioned steps.) Input the User ID, for example, 08 from the outside keypad. When one beep is heard, the User ID is entered successfully. Rest the finger on the scanner (scanner light will flash three times) and move it away when the light turns off finally. When one long beep is heard, the user is enrolled successfully. If three beeps are heard, and the red LED flashes three times, the user enrollment fails. Notes:

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

3 1) During the above operations, whenever the red LED flashes three times, the operation fails. Please follow the previous steps to try again. If it keeps failing, please change the fingers and try again. 2) As soon as one user is enrolled, the green LED will keep on for a while (5 seconds). Other users can be enrolled with no need to have administrators verified again. If you want to quit from the process, just press any non-numeric button at the outside keypad. Deleting Fingerprint Users Press DEL button. When the red LED and the scanner light turn on, rest the administrator’s finger on the scanner. Move the finger away when the scanner light turns off. (If the green LED flashes three times, the administration is verified successfully.) Enter the ID number of the User who should be deleted (for example, if the ID is 08, enter 08). When three beeps are heard and the green LED flashes three times, User 08 has been deleted successfully. (Other users can be deleted with no need to restart the process as soon as the first one is deleted.) If the red LED flashes three times, the deletion fails. Please check the lock and follow the above steps. Note: As soon as one user is deleted, the red LED will keep on for a while (5 seconds). Other users can be deleted without the need to have administrators verified again. If you want to quit from the processes, just press any non-numeric button at the outside keypad. Setting PIN codes Notes: 1) The PIN code can be 10 digits max. and one digit min. It is a code of any combination of 0 to 9. 2) The lock can have 99 groups of PIN code. All the users can have their own PIN code under the User ID. 3) The factory-set PIN code is 123. I. Enrolling the master Administrator PIN code Enter * (star) + 123 + ADD (red LED flashes one time and green LED flashes three times) + 01 (master Administrator User ID) (green LED flashes one time) + master Administrator PIN code + * (green LED flashes one time)+ mater Administrator PIN code again + * (star). For example: If the master Administrator PIN code which is going to be enrolled is 123456, here is the correct way to enroll it. * (star) + 123 + ADD (red LED flashes one time and green LED flashes three times) + 01 (green LED flashes one time)+ 123456 + * (green LED flashes one time)+ 123456 + *

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

4 When the red LED flashes one time, the green LED turns on and one long beep is heard, the new PIN code is enrolled successfully. If the red LED flashes one time following any of the above operations, the setting fails. Please check it and repeat the previous operation steps. II. Enrolling Administrator 02 PIN code Enter * (star) + the master Administrator PIN code + ADD (red LED flashes one time green LED flashes three times) + 02 (green LED flashes one time) + Administrator 02 PIN code + * (green LED flashes one time)+ Administrator 02 PIN code again + * (star). For example: If the master Administrator PIN code 123456, and Administrator 02 PIN code which is going to be enrolled is 45678, here is the correct way to enroll it. * (star) + 123456 + ADD (red LED flashes one time and green LED flashes three times) + 02 (green LED flashes one time)+ 45678 + * (green LED flashes one time)+ 45678 + * When the red LED flashes one time, the green LED turns on and one long beep is heard, the new PIN code is enrolled successfully. If the red LED flashes one time following any of the above operations, the setting fails. Please check it and repeat the previous operation steps. III. Enrolling User PIN codes Enter * (star) + Administrator PIN code + ADD (red LED flashes one time green LED flashes three times) + User ID (green LED flashes one time) + User PIN code + * (green LED flashes one time)+ User PIN code again + * (star). For example: If the Administrator PIN code 123456, the User ID is 08 and the User PIN code which is going to be enrolled is 32433, here is the correct way to enroll it. * (star) + 123456 + ADD (red LED flashes one time green LED flashes three times) + 08 (green LED flashes one time)+ 32433 + * (green LED flashes one time)+ 32433 + * When the red LED flashes one time, the green LED turns on and one long beep is heard, the new PIN code is enrolled successfully. If the red LED flashes one time following any of the above operations, the setting fails. Please check it and repeat the previous operation steps. Notes: 1) Other PIN codes can be enrolled with no need to restart the process as soon as one PIN code is enrolled. If you want to quit, just press any non-numeric button at the outside

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

5 keypad. 2) The PIN codes for User ID 01 and 02 are both administrator PIN codes which are able to enroll or delete the PIN codes for users. 3) All the PIN codes are individual. No identical PIN codes can be enrolled for different users. IV. Changing PIN codes Enter * (star) + Administrator PIN code + ADD + User ID + New User PIN code + * (star) + New User PIN code again + * For example: If the Administrator PIN code 123456, the User ID is 08 and the new User PIN code which is going to be enrolled is 85000, here is the correct way to enroll it. * (star) + 123456 + ADD (red LED flashes one time and green LED flashes three times) + 08 (green LED flashes one time)+ 85000 + * (green LED flashes one time)+ 85000 + * When the red LED flashes one time, the green LED turns on and one long beep is heard, the User PIN code is changed successfully. If the red LED flashes one time following any of the above operations, the setting fails. Please check it and repeat the previous operation steps. Note: Other PIN codes can be changed with no need to restart the process as soon as one PIN code is done. If you want to quit, just press any non-numeric button at the outside keypad. V. Deleting PIN codes Enter * (star) + Administrator PIN code + DEL (red LED flashes one time and green LED flashes three times) + User ID whose PIN code is going to be deleted For example: If the Administrator PIN code 123456, the User ID whose PIN code is going to be deleted is 08, here is the correct way to enroll it. * (star) + 123456 + DEL (red LED flashes one time and green LED flashes three times) + 08 When the red LED flashes one time, the green LED flashes three times and three beeps are heard, the User PIN code is deleted successfully. If the red LED flashes one time following any of the above operations, the deletion fails. Please check it and repeat the previous operation steps. Note:

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

6 1) Other PIN codes can be deleted s soon as one PIN code is done. If you want to quit, just press any non-numeric button at the outside keypad. 2) The PIN codes for Administrator 01 and 02 are Administrator PIN codes. Neither of them can be deleted individually, but they can be done by resetting the lock. Regarding how to reset the lock, please contact the local dealer or the manufacturer. Setting the Matching Mode There are three choices for how the Polysecu® LP808 will verify enrolled users for access to unlock the door: • 1:N…When this is chosen, all users enrolled at this lock will only need to match their enrolled Fingerprint or PIN Code to successfully unlock the door. • 1:1…When this is chosen, all users enrolled at this lock must enter their User ID, then verify their enrolled Fingerprint to successfully unlock the door. • PIN code & Fingerprint…When this is chosen, all enrolled users at this lock must enter their PIN codes, then verify their enrolled Fingerprints to successfully unlock the door. 1. 1:N (one to many) Enter #3 (green LED flashes one time) + Administrator PIN code + # (red LED flashes one time and green LED flashes three times) + 0 When the green LED turns on and one long beep is heard, the lock is on 1:N opening mode. If the red LED flashes three times, the setting fails. 2. 1:1 (one to one) Enter #3 (green LED flashes one time) + Administrator PIN code + # (red LED flashes one time and green LED flashes three times) + 1 When the green LED turns on and one long beep is heard, the lock is on 1:1 unlocking mode. If the red LED flashes three times, the setting fails. 3. PIN code & Fingerprint Enter #3 (green LED flashes one time) + Administrator PIN code + # (red LED flashes one time and green LED flashes three times) + 2 When the green LED turns on and one long beep is heard, the lock is on PIN code & Fingerprint

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

7 unlocking mode. If the red LED flashes three times, the setting fails. Automatic Locking Mode (ALM) & Temporary Unlocking Mode (TUM) setting 1. Set TUM Enter #1 (green LED flashes one time) + Administrator PIN code + # (red LED flashes one time and green LED flashes three times) + 1. When the green LED turns on and one long beep is heard, the lock is TUM mode. 2. Set ALM Enter #1 (green LED flashes one time) + Administrator PIN code + # (red LED flashes one time and green LED flashes three times) + 0. When the green LED turns on and one long beep is heard, the lock is TUM mode. Notes: 1). TUM or ALM is effective no matter fingerprint or PIN code is used to unlock the door. 2). The system default mode is ALM. Anti Malicious Use Function Setting 1. To arm the Anti Malicious Use function Enter #2 + Administrator PIN code + # (red LED flashes one time and green LED flashes three times) + 1. When the green LED turns on and one long beep is heard, the Anti Malicious Function is armed. 2. To disarm the Anti Malicious User function Enter #2 + Administrator PIN code + # (red LED flashes one time and green LED flashes three times) + 0. When the green LED turns on and one long beep is heard, the Anti Malicious Function is disarmed. Note: 1) When the Anti Malicious User function is armed, the lock will enter the temporary dead condition if there have 5 continuous opening attempts with fingerprints or PIN codes happening to the lock. 2) Under this condition, the lock is completely dead no matter any button is entered at the outside unit. 3) This condition will last 3 minutes once it starts.

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

8 LP808A OPERATION INSTRUCTIONS 1) ) ) )Unlock with fingerprints under 1:N matching mode Press down on the POWER button at the outside unit. Rest the enrolled user’s finger on the scanner when it powers on. When one single beep is heard, and the green LED powers on, turn the knob clockwise to unlock. If three beeps are heard and the red LED flashes, the verification fails and the access is rejected. In this case, please repeat the above operation steps. 2) ) ) )Unlock with PIN codes under 1:N matching mode Enter the added PIN code at the outside keypad directly, and end up with pressing the # button. When one single beep is heard and the green LED powers on, turn the knob clockwise to unlock. If three beeps are heard and the red LED flashes, the verification fails and the access is rejected. In this case, please repeat the above operation steps. 3) ) ) )Unlock with fingerprints under 1:1 matching mode Enter the User ID at the outside keypad directly, and the POWER button as well. Rest the enrolled user’s finger corresponding to the User ID on the scanner when it powers on. When one single beep is heard, and the green LED powers on, turn the knob clockwise to unlock. If three beeps are heard and the red LED flashes, the verification fails and the access is rejected. In this case, please repeat the above operation steps. 4) ) ) )Unlock with PIN Code + fingerprint Enter the added PIN code at the outside keypad directly, and the POWER button as well Rest the enrolled user’s finger corresponding to the User ID on the scanner when it powers on. When one single beep is heard and the green LED powers on, turn the knob clockwise to unlock. If three beeps are heard and the red LED flashes, the verification fails and the access is rejected. In this case, please repeat the above operation steps. 5) ) ) )Unlock with the override keys Insert the key vertically into the keyhole in the outside handle, turn it at 90 degrees clockwise, and then turn the turning knob to unlock. EU809 Operations on the Inside Unit  Key IR: : : :Arming the Infra-Red alarm system Quick Arming  Press down on Key IR and hold it for 2 seconds until a long beeping is heard and

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

9 the lock begins to count down for 15 seconds (one beep every two seconds). Before the down counting finishes, press Key IR again to stop beeping manually, with the outside turn knob entering into the Unlocking Mode immediately. The outside turn knob will be locked again in 6 seconds after then and the lock will send out the arming signal to the Infra-red alarm system. Normal Arming  Press down on Key IR and hold it for 2 seconds until a long beeping is heard and the lock begins to count down for 15 seconds (one beep every two seconds). When the down counting finishes, the outside turn knob will enter into the Unlocking Mode and be locked again in 3 seconds. After then the lock will send out the arming signal to the Infra-red alarm system.  Key : : : :Arming the Non-Infra-red Alarm System Quick Arming  Press down on Key and hold it for 2 seconds until a long beeping is heard and the lock begins to count down for 15 seconds (one beep every two seconds). Before the down counting finishes, press Key again to stop beeping manually, with the outside turn knob entering into the Unlocking Mode immediately. The outside turn knob will be locked again in 6 seconds after then and the lock will send out the arming signal to the Non-Infra-red alarm system. Normal Arming  Press down on Key and hold it for 2 seconds until a long beeping is heard and the lock begins to count down for 15 seconds (one beep every two seconds). When the down counting finishes, the outside turn knob will enter into the Unlocking Mode and be locked again in 3 seconds. After then the lock will send out the arming signal to the Non-Infra-red alarm system.

Easy2Access A/S Easy-809 EU G2 Fingerprint lock

10  Key : Disarming the Alarm system Press this key and hold it for 2 seconds. When a long beep is heard, the lock has sent out the disarming signal to the alarm system.  Key R + Reset Button: Reset the lock Remove the battery cover and find the small Reset button down in the hole underneath the battery holder. Press down the Reset button with a long and slim stick and then press down Key R on the navigation wheel as well. When both the red and green LED turn on, and two long beeps are heard, the lock has been successfully reset.