The Raytector is used for entrapment protection on industrial doors, mainly for

rolling grills. An interruption of the light beam initiates a signal between transmitter and receiver which stops the movement of the power operated Door. The entrapment protection RAYTECTOR is suitable for doors between 1.5 to 10.5 m wide 10.16 Raytector System Door kit For TS 959/970/971 GfA ELEKTROMATEN UK Ltd Unit 1, Titan Business Centre, Spartan Close Warwick CV34 6RR, England. Telephone: 01 926 452452 Fax: 01 926 336417 E-mail: sales@ gfa-elektromaten.co.uk Web Site: www.gfa-elektromaten.co.uk ELECTRICAL WIRINGINSTRUCTIONS

GF304528 RAYTECTOR Connection Drawing

IMPORTANT! READ THE RAYTECTOR INSTRUCTIONS FOR ESSENTIAL INSTALLATION AND TESTING PROCEDURES. 5.1 5.2 5.3 5.4 3.1 3.2 20.3 20.2 20.1 1.8 1.9 F1 = 1,6A t 1 BN 2 WE 4 GN1 5 6 GN2 OSE-C 2300 2 x OSE 1 x OSE RELAY 2 RELAY 1 RELAY 3 TRANSFORMER 34 33 OSE 24 23 REV A1 A2 Power VITECTOR RAYTECTOR RAY - R 1000 Receiver RAY - T 1000 Transmitter light barrier inside VITECTOR RAYTECTOR RAY - T 1000 Transmitter RAY - R 1000 Receiver light barrier outside BROWN WHITE GREEN BROWN WHITE GREEN BROWN WHITE GREEN BROWN WHITE GREEN 4 x BROWN 4 x WHITE 2 x GREEN 2 x GREEN REMOVE LINK TERMINALS 5 - 6 RAYTECTOR HIGH LEVEL ENTRAPMENT PROTECTION BARRIERS