Fourtec DaqPRO 5300 Operation & User’s Manual

File Specifications

Brand: Fourtec
Category: Data Loggers
Model: DaqPRO 5300 (Operation & User’s Manual), prdd1vkr4oTyw
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 99 pages

Download PDF

Download Fourtec DaqPRO 5300 Manual (99 pages)

Read Online:

Read the Fourtec DaqPRO 5300 Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

© fourtec – Fourier Technologies Ltd.

www.esis.com.au Ph 02 9481 7420 Fax 02 9481 7267 [email protected] ...

Chapter 2 Working with DaqLab

27 If auto run is not working, open My Computer and click on the CD drive folder (d: drive in most cases) and double-click on the setup icon, then follow the on-screen instructions. To uninstall the software: From the Start menu select Settings and click on Control Panel, then use the Add/Remove Programs feature to remove the DaqLab application. When updating the software, always remove the old version before starting a new installation. To install the USB driver on WinXP: 1. Connect your data logger to a USB port on your PC and turn the data logger on. Windows wi ...

Chapter 1 DaqPRO

1.1.5. Alarms Users can define minimum and maximum alarm levels for each input individually. DaqPRO places a small alarm icon next to the corresponding input readings and can switch alarm output if either level is breached. To display alarm warnings in real-time DaqPRO must be in numeric display mode (see page 14). To learn how to enter alarm levels and to activate alarm output, see section 2.5.1.2 on page 49. 1.1.6. Alarm Output DaqPRO can trigger an external event (e.g. sound alarm, warning light or oven). Connect the external current loop to the screw terminals of I/O� ...

Chapter 1 DaqPRO

Connect the sensor to the terminal block at the top of DaqPRO: Figure 2: DaqPRO’s inputs block terminal Sensors must be added successively, starting with input–1. If a single sensor is used it must be connected to Input–1. If two sensors are used, they must be connected to Input-1 and Input-2 and so on. Alarm Output I/O–8 (Input/Output–8) serves either as an input or as alarm output. Polarity Current, voltage, thermocouples and user defined sensors have distinct polarity. Be careful to connect them in the right polarity. Frequency/Pulse Counter Connect the signal w ...

Chapter 2 Working with DaqLab

b. The first column should be the time. The time interval between successive rows must match the time intervals accepted by DaqLab. You can export DaqLab files to Excel to learn about these time formats. For example, refer to the table below: 2. On the File menu, click Save As. 3. In the File name dialog box, type a name for the workbook. 4. In the Save as type list, click the CSV format. 5. Click Save. To import files that were previously exported from DaqLab, open DaqLab and import the file as described above (as they are already in CSV format). 2.3.8. Date F ...

Chapter 3 Troubleshooting

Chapter 3 Troubleshooting Guide Symptom Cause of Problem I pressed the ON key on DaqPRO and it did not turn on. • Try charging the battery, it may be weak. • You are using an unsuitable AC/DC adaptor (refer to page 9). • The internal 3V disk battery is dead. DaqLab was unable to connect to DaqPRO. • DaqPRO is turned off. • The communication cable is not connected properly. • The communication cable is not connected to the correct PC COM Port. • There is no available Serial COM Port. DaqPRO and DaqLab displays a warning message: Illegal sensor • DaqP ...

Chapter 1 DaqPRO

1.1.2. External Connections Figure 1: DaqPRO external connections 1 st input 2. PC USB connection socket 3. Power input (DC 9 – 12V) 1. Sensor Inputs/Alarm output 8 th input/output www.esis.com.au Ph 02 9481 7420 Fax 02 9481 7267 [email protected] ...

Fourtec DaqPRO 5300 user guide recommended for: TRACK-IT, LR5051, RO-1 VW Note, CR800, LabQuest Stream.

⚠️ Download Safety

The Data Loggers Operation & user’s manual (99 pages) is completely safe to download (last scan date: 29/01/2026).

Related PDF Instructions for Fourtec DaqPRO 5300:

Data Loggers Equipment: Frequently Requested

Have some Questions about Fourtec DaqPRO 5300 Device?

Get valuable and actionable advices from other Fourtec DaqPRO 5300 device users. Describe your problem or question, regarding the using of DaqPRO 5300, in as much detail as possible, and other users will be able to answer you.