Netafim nmc-pro Operation & User’s Manual
File Specifications
| Brand: | Netafim |
| Category: | Irrigation System |
| Model: | nmc-pro (Operation & User’s Manual), pr5G/hK60ZIA6 |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 60 pages |
Download PDF
Download Netafim nmc-pro Manual (60 pages)Read Online:
Read the Netafim nmc-pro Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
NMC-PRO User Manual
Page 16 PROGRAM MENU 2.2.5 54BEC Pre-Control Use this option in hydraulic pre-control systems in greenhouses. When collecting excess water from drains, the grower can set an EC target before water goes through an irrigation system. This method reuses excess fertilizer and water, recycling them for a second irrigation run. Note: An EC Pre-Control valve relay must be defined by a technician at installation. EC Pre-Control ON (this enables the control) Define pre-controlled EC target DOSING PROGRAM Program: 1 EC Pre-Control: ON INJECTION PER DOSING CHANNEL ...
NMC-PRO User Manual
Page 11 PROGRAM MENU 2.2 1BDosing Program For every irrigation program, define a Dosing Program that defines the quantity of fertilizer per channel and its delivery method. You can define up to 10 Dosing Programs. Note: If there is more than one fertilizer tank for the selected dosing channel, refer to Selector, page 38. 3. Dosing Dosing can be according to one of the following: • Proportional quantity • Proportional time • Quantity • Time 2.2.1 50BProportional Quantity Proportional Quantity is the quantity of fertilizer distributed per quantity of water. The p ...
NMC-PRO User Manual
Page 31 PROGRAM MENU Example: As sunlight increases, a crop needs lower EC levels. The following screen illustrates increasing in the EC based on radiation. Since Irrigation Pro calculates the decrease in EC proportionally, there will be a 15% decrease when the radiation reaches 600 w/m2. 2.8.3 58BDrainage Influence on Target Radiation Sum Irrigation can be triggered by the Radiation Sum (Rad Sum). This Influence enables adjusting the Rad Sum based on the amount of drainage. To set the Drainage Influence on Rad Sum: 1. In Program > Irrigation, set Contr. to Rad Sum. 2. In ...
NMC-PRO User Manual
Page 10 PROGRAM MENU 2. Water Run Time Qty. Define Time o Define value for "before" and "after" time program Note: Whatever figure you enter in Before/After is deducted from the total run time/quantity. For example if the run time is 15 minutes, a Before time of two minutes and After time of one minute, then the net dosing time is 12 minutes. WATER RUN TIME PROGRAM # Method Water Before After 1 2 3 4 5 6 7 8 9 TIME QTY. QTY. QTY. QTY. QTY. QTY. QTY. QTY 00:15:00 25.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 00:0200 5.000 0.000 0.000 0.000 0.000 0.000 0.000 0 000 00: ...
NMC-PRO User Manual
Page 22 PROGRAM MENU In this example, the seven day cycle begins on the fourth day (04/07). On the fourth day, the irrigation is water only (no dosing). 1 2 3 4 5 6 7 D - D W D - D 2.4 13BIrrigation Based on External Conditions Irrigation can be controlled by input from dry contact or analog sensor triggers. • If the Irrigation Program is active, these programs can only function after the Irrigation Program is completed. • If the Irrigation Program is inactive, these programs can function during the defined time frame. • In both cases, irrigation begins only when exte ...
NMC-PRO User Manual
Page 29 PROGRAM MENU • VPD Sum Limit: This parameter determines the minimal (accumulated) VPD required for irrigation to start. • Minimum Time: When irrigation begins, NMC Pro erases the current VPD sum and restarts the count. Minimum time is the minimal amount of time between irrigation starts, even if the radiation sum has reached its limit. • Maximum Time: This parameter determines the maximum amount of time between irrigation starts, even if the VPD limit has not been reached. 2.7 16BIntroduction to the Influence Program Irrigation Pro enables adjusting irrigation ...
NMC-PRO User Manual
Page 8 GENERAL INFORMATION To change the operation mode, press the LOG IN key Click the MODE icon and insert the password The controller recognizes the operation mode according to the password that is entered: MODE PASSWORD Read Only 0000 User 9785 or 0101 If an incorrect password is entered, this screen appears. The Operation mode can be configured to automatically return to the “Read-Only” mode after a certain amount of time. Note: Refer to the SYSTEM SETUP section in the Installation Manual. SYSTEM SETUP HISTORY History Resolution ► 1 HOUR WEATHER STATION Contr ...
Netafim nmc-pro user guide recommended for: TECHLINE AS, MegaNet 15D, D-Net 6550, NLC-100SH, FROSTIE.
⚠️ Download Safety
The Irrigation System Operation & user’s manual (60 pages) is completely safe to download (last scan date: 16/03/2026).
Related PDF Instructions for Netafim nmc-pro:
-
Netafim NMC-64 Controller User & installation manual
NMC-64100 -
Netafim D-Net 6550 Irrigation System Operation & user’s manual
D-Net 655014 -
Netafim M Series Measuring Instruments Installation, operation and maintenance manual
M Series8 -
Netafim SMART & GREEN 429854 Irrigation System Manual
SMART & GREEN 4298542 -
Netafim nmc-pro Controller Installation manual
nmc-pro167 -
Netafim NETAFLEX 3G Industrial Equipment Operation & user’s manual
NETAFLEX 3G32
Irrigation System Equipment: Frequently Requested
-
FarmTek Growers Supply HydroCycle Irrigation System
22.01.2026Operation guide for the FarmTek Growers Supply HydroCycle Irrigation System. The guide explains operation and installation, safety protocols, safety guidelines, cleaning instructions.Growers Supply HydroCycle, 25 -
Reliable F1 Series Irrigation System
10.12.2025Comprehensive instruction manual for the Reliable F1 Series Irrigation System. It provides instructions for product safety, replacement parts, startup procedures.F1 Series, 6 -
Tyco RAPID RESPONSE Series Irrigation System
12.03.2026Operating manual for the Tyco RAPID RESPONSE Series Irrigation System. This manual provides information on setup, error handling, performance details, energy usage.RAPID RESPONSE Series, 5 -
Hunter Hydrawise Pro-HC Controller
07.12.2025Product usage guide for the Hunter Hydrawise Pro-HC Controller. It describes operating procedures and reset instructions, setup, service procedures.Hydrawise Pro-HC, 72 -
Reliable J112 Pendent Irrigation System
13.04.2026Service and user manual for the Reliable J112 Pendent Irrigation System. It offers guidance for setup and technical guidelines, device instructions, shutdown procedures.J112 Pendent, 7 -
Tyco Fire Product Gem ISSUE D QUARTZOID Irrigation System
25.01.2026User instruction manual for the Tyco Fire Product Gem ISSUE D QUARTZOID Irrigation System. The guide covers usage and detailing setup, maintenance guidelines, network setup, calibration steps.Gem ISSUE D QUARTZOID, 2
Have some Questions about Netafim nmc-pro Device?