Page 28 ELECTRICAL INSTALLATION • NetSense, page 28 • Ech2o 5, page 29 • NetSense / Ech2o 5 Jumper Position, page 31 4.3.2.1 NetSense • NetSense Specifications • NetSense Installation 4.3.2.1.1 NetSense Specifications • Stainless Steel with plastic coating • All electronics are sealed in water-proof epoxy • Temperature range:  Operating: 0° to 50° C  Storage: -20° to 60° C • Output format: 0.5 - 5.0 mA • Power requirements: 5.5 - 18 VDC, 10 - 20 mA (max) • Accuracy: 1% Volumetric Soil Moisture  Note: Less accuracy may be experience ...

NMC-PRO Installation Manual

Page 42 ELECTRICAL INSTALLATION 4.5.5 Analog Input Definition  Note: For sensor installation and definition, please refer to Appendix D. 4.5.6 Analog Output Definition 1. In the Installation menu, select Device Layout. 2. In the screen that appears, define the required number of channels as Dosing channels.  Note: The possible number of Dosing Channel depends on the number of installed analog output cards. 3. In the Installation menu, select Analog Output. ...

NMC-PRO Installation Manual

Page 100 SETUP MENU WEATHER STATION • Controller function: Define whether this controller is connected to a weather station directly or through the network.  Local: A weather station is connected to this controller; its data is used locally only and should not be passed or received through the network.  Slave: This controller receives weather station data through the network; the data is collected by another NMC-Pro (or NMC-64 Climate), which is connected directly to a weather station defined as Master. Sensors connected directly to a slave controller will b ...

NMC-PRO Installation Manual

Page 124 INSTALLATION MENU  Note: After making changes, be sure to exit and return again to check for errors. The NMC-Pro will delete and replace conflicting assignments with ‘---‘. Screen 1 Screen 2 Screen 3 Screen 4 Screen 5 ...

NMC-PRO Installation Manual

Page 161 SENSOR INSTALLATION AND DEFINITION 17.8 Sensor and Cable Specifications Sensor Type Measured Values Accuracy Input Range Maximum Cable Length Cable Type Temperature – RTS-s -20° to 50° C/ -4° to 122°F 0.3°C/0.54°F 30 kOhm 500 meter (1640 feet) 2x0.5 mm² (20 AWG) EC 0 to 10 mS (old transmitters used 20 mS) 0.05 to 0.1 mS 4 – 20 mA --- 3x0.5 mm² (20 AWG) Shielded pH 0 - 14 0.1 4 – 20 mA --- RH – RHS-10 0 – 100% ±2% (10%- 90% RH), ±3.5% (90%- 100% RH) 0 – 3 VDC 300 meter (985 feet) 3x0.5 mm² (20 AWG) Solar Radiation- Davis 300-1100 nanom ...

Netafim nmc-pro user guide recommended for: SMART & GREEN 429854, TECHLINE CV, AlphaDisc BLE, AQUA PRO, TECHLINE AS.

⚠️ Download Safety

The Controller Installation manual (167 pages) is completely safe to download (last scan date: 13/11/2025).

Related PDF Instructions for Netafim nmc-pro:

Controller Equipment: Frequently Requested

Have some Questions about Netafim nmc-pro Device?

Get valuable and actionable advices from other Netafim nmc-pro device users. Describe your problem or question, regarding the using of nmc-pro, in as much detail as possible, and other users will be able to answer you.