Force Flow WIZARD 4000 Installation & Operation Manual
Text of the manual
INSTALLATION & OPERATION
ELECTRONIC 5-GALLON TO 30-GALLON CARBOYS OR DRUMS
WITH WIZARD 4000 (1 TO 4 CHANNEL INDICATOR)
factory calibrated
factory calibrated
s/n __________________
s/n __________________
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 Fax: 925-686-6713
www.forceflow.com / [email protected]
Version: PR128G
R E F : T 4 \ O & M \ C A R B W I Z \ C V R C A R W Z . t c w ( L 0 0 . p d f )
R E F : T 4 \ O & M \ C A R B W I Z \ C V R C A R W Z . t c w ( L 0 0 . p d f )
W I Z A R D 4 0 0 0
W I Z A R D 4 0 0 0
SCALE 1 350 LBS
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
WIZARD 4000
CARBOY-SCALE
CARBOY-SCALE
TM
WIZARD 4000
WIZARD 4000
77
INDICATOR:
INDICATOR:
CARBOY-SCALE
SCALE:
SCALE:
UP TO 4 SCALES PER INDICATOR
UP TO 4 SCALES PER INDICATOR
F L O Q
U I
P
INCLUDES MODELS:
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
WWW.FORCEFLOW.COM / [email protected]
REF: T4\O&M\CARBWIZ\MODELNO.tcw (L0A.pdf)
ELECTRONIC
CARBOY-SCALES
with WIZARD INDICATOR
1- to 4-Channel Indicator
FOR CAPACITIES:
8" (203mm) to 24" (610mm) Diameters
FOR CARBOYS & DRUMS:
COVERING MODELS:
5-Gallon to 30-Gallon Carboys & Drums
WR200-1 to WR200-4 (200 lbs)
WR400-1 to WR400-4 (400 lbs)
WR600-1 to WR600-4 (600 lbs)
NOTE: Carboy-Scale model numbers "WR"
were formerly "DR" and interchangable.
(WR100K-1 to WR100K-4 100 kg.)
(WR200K-1 to WR200K-4 200 kg.)
(WR300K-1 to WR300K-4 300 kg.)
MODEL NUMBERS
(METRIC MODELS)
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
REF: T4\O&M\INDEX.\Y06.tcw etc (Y06.pdf etc)
SECTION
W.2.000
INDICATOR OPERATION
W.2.101
W.2.102
W.2.103
Keyboard Display Selections
Keyboard Menu - Quick Reference
Tank Load Mode
W.3.000
Code 9081 (Field Calibration)
Calibration of Slotted Platforms
Troubleshooting Tips
Parts List
WIZARD Indicator with CARBOY-SCALE
INDEX
Code 9080 (Scale Set Up)
Code 9082-9083 (Feed Rate Format/Display Units)
Code 9084-9086 (Single or Dual Display/Tank Loading/Printer)
Code 9086 (cont...)-9089 (Time/Date/Calibration/Channels)
Code 4200 & 3256 (Set Point Configuration/4-20mA Output Configuration)
Code 3256 (cont...)
Indicator Wiring & Plumbing
Indicator Installation Instructions
Wizard Component Layout
INSTALLATION CHECK OFF LISTS
W.1.301
W.1.305
INDICATOR INSTALLATION
W.1.201
W.1.202-203
W.1.204
Installation Check-Off List
Installation Start-Up Check-Off List
SET-UP CODES - CUSTOM FORMATTING
W.2.201
W.2.202
W.2.203
W.2.204
W.2.205
W.2.206
MEMU OF DAY-TO-DAY OPERATIONS
W.2.104
W.2.105
W.2.106
W.2.107
W.2.108
MISCELLANEOUS
W.3.101
W.3.102
W.3.301
W.3.401
Low Level Alarm & Date Last Cleared
Clear Amount Used & Set Scale Zero
Set Scale Zero cont... & Allarm Reset
Review Daily Usage & Printing Report
Report (example) & Protocol
YOU
ARE
HERE !
INSTALLATION INSTRUCTIONS
W.1.101
W.1.101-4
W.1.102
W.1.103
W.1.104
W.1.105
W.1.106
W.1.108
Scale Drawing
1 to 4 Channel Configuration Drawing
Installation Drawing
Installation Introduction
Installation Instructions Steps 1 thru 4a
Installation Instructions Steps 4b thru 4f
Installation Instructions Steps 4g thru 5
Scale Operation
FORCE FLOW EQUIPMENT
SCALE
SELECT
DISPLAY
SELECT
TOTALS
PRINT
F1
TANK
LOAD
MENU
MENU
DEL
ENTER
0
9
1
2
3 4
5
6 7 8
SCALE 1 150 LBS
SCALE 2 300 LBS
Allows changing of tanks. To maintain accurate usage data,
DO NOT change tanks until STEP 4.
Press TANK LOAD button
Press 1 2 3 or 4 to select which scale, then press ENTER.
Press MENU to select AUTO or MANUAL tare entry, then press ENTER
Change your tank(s) now ! Then press ENTER.
If MANUAL is chosen: Key in tank tare weight(s) via numeric key pad,
then press ENTER.
Toggles through display options:
Net Remaining, Amount Used,
Average Feed Rate, Days Until
Empty, Daily Usage, Tare Weight
and Gross Weight.
Toggles through
display for the
totals of all
scales
Backspace or Escape
Menu Operations
Accept Data or
Proceed to
next function
1
2
3
4
5
TANK
LOAD
DISPLAY
SELECT
TOTALS
DEL
ENTER
CALIBRATION
RING
1-5/8" (41mm)
PLATFORM MOUNTED LEVEL VIAL
ADJUSTABLE BACKSTOP
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
Drawn by: SLP
Date: 01/04/94
Revised: 05/07/98
Scale: NONE
Drawing Number
File: T4\O&M\CARBWIZ\CARBWIZ.tcw (L08.pdf) (WEB: CARBWIZ.pdf) 7/01
30277
ELECTRONIC CARBOY-SCALE
with WIZARD 4000 INDICATOR
FORCE FLOW
WR200
WR400
WR600
(Includes WIZARD 4000 indicator)
Consult factory for other capacities; multiple channels or metric models.
NOTE: Model letters WR were formerly DR and interchangeable.
18 1/2" (470mm)
21 3/4" (546mm)
24" (610mm)
13 1/2"(343mm)
15 3/4" (400mm)
24" (610mm)
FORCE FLOW
F L O Q
U I
P
200 lb cap.
400 lb cap.
600 lb cap.
16 1/2" (419mm)
18 3/4" (475mm)
27" (686mm)
Model Numbers
X
Y
Z
Tank Diameter
8" to 16"
14" to 19"
18" to 24"
W.1.101
UP TO 4 SCALES PER INDICATOR
Three 4-20 mA Output
One 120 Volt AC Power
Four 4-20 mA Output
One 120 Volt AC Power
Two 4-20 mA Output
One 120 Volt AC Power
One 4-20 mA Output
One 120 Volt AC Power
Models:
DR200-3 (Metric: DR100K-3)
DR400-3 (Metric: DR200K-3)
DR600-3 (Metric: DR300K-3)
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
Drawn by: SLP
Date: 04/21/97
Revised: 08/16/00
Scale: NONE
Drawing Number
File: T4\O&M\CARBWIZ\CARBWIZ1.tcw (L01.pdf)
30011
CARBOY-SCALE with WIZARD INDICATOR
Model DR200 thru DR600 Series
(Metric Models also available)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.1.101-4
Models:
DR200 (Metric: DR100K)
DR400 (Metric: DR200K)
DR600 (Metric: DR300K)
Models:
DR200-2 (Metric: DR100K-2)
DR400-2 (Metric: DR200K-2)
DR600-2 (Metric: DR300K-2)
Models:
DR200-4 (Metric: DR100K-4)
DR400-4 (Metric: DR200K-4)
DR600-4 (Metric: DR300K-4)
1 Single Carboy Electronic Scale with
1 Wizard 4000-1 (1 each Channel /4-20mA Output)
Optinoal Accessory: Low Level Alarm (1 required per channel)
3 Single Carboy Electronic Scales with
1 Wizard 4000-3 (3 each Channel /4-20mA Output)
Optinoal Accessory: Low Level Alarm (1 required per channel)
4 Single Carboy Electronic Scales with
1 Wizard 4000-4 (4 each Channel /4-20mA Output)
Optinoal Accessory: Low Level Alarm (1 required per channel)
2 Single Carboy Electronic Scales with
1 Wizard 4000-2 (2 each Channel /4-20mA Output)
Optinoal Accessory: Low Level Alarm (1 required per channel)
Read Installation Instructions thoroughly
before installing.
4
1
2
3
5
Step
Step
Step
Step
Step
1. Place Platform on Floor
2. Level Platform
3. Anchor the Platform
4. Anchor the Load Cell
5. Mounting Additional Scales
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
Drawn by: SLJ
Date: 02/15/93
Revised: 07/29/98
Scale: NONE
Drawing Number
File: T4\O&M\CARBWIZ\CARBO&M5.tcw (LS03.pdf)
30012
CARBOY-SCALE
Electronic Scale for Weighing
5- to 30-Gallon Carboys & Drums
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
S.1.102
W.1.102
Two (2) Adjustable Wrenches
Screw Driver and Tape Measure
Hammer (for pounding in anchor bolts)
Carboy/Drum (for aligning platform)
To prevent possible personal injury or damage to the equipment
through misuse, this equipment should be installed, operated and
serviced only by trained, qualified personnel who are thoroughly familiar with the
entire contents of this Instruction Manual, which should be thoroughly reviewed and
understood prior to installing and operating the equipment.
Power Drill and Drill Bits
Hammer Drill and Masonry Bit (5/16")
Two (2) 1/4" Diameter Anchors (for platform)
Four (4) properly chosen Anchors (for Indicator)
Your Electronic CARBOY-SCALE consists of two basic assemblies:
1. Load Cell System (Load Cell, Cable and Indicator)
2. PVC Platform (Backstop, Platform with Hinge and leveling shims)
Electronic CARBOY-SCALE
If you have any questions regarding the installation, operation or maintenance on your
CARBOY-SCALE, please do not hesitate to call our.... HELP HOTLINE 1-800-893-6723.
COMMENTS:
ITEMS REQUIRED FOR INSTALLATION:
WARNING:
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
WWW.FORCEFLOW.COM / [email protected]
REF: T4\O&M\CARBWIZ\CARBO&M1.tcw (L02.pdf)
S.1.103
W.1.103
1" Clearance between
platform and wall
DO NOT anchor platform to floor until Step 3 !
(A) Place the platform on the floor with the backstop
side of the platform at the wall. (NOTE: Allow at
least 1" clearance between wall and platform)
CAUTION: For proper operation and to avoid possible damage to the scale or injury to yourself, you MUST install
these items in the following Step-by-Step manner. The Electronic CARBOY-SCALE should be used with carboys
which have outside diameters of 8" to 19", and gross weights from 200 to 400 lbs. Remove all items from box.
The load cell system is wired and calibrated at the factory.
(B) Remove stud from Load Cell and place Load Cell
underneath Platform so that the "BLACK DOT" on
Load Button is centered in the hole in the back
of the Platform.
CORRECT
CLOSE-UP DETAIL
PLATFORM
CENTER THE BLACK DOT
LINE OF SIGHT
INCORRECT
STEP 1: PLACE PLATFORM ON FLOOR
INSTALLATION NOTES:
STEP 2: LEVEL PLATFORM
Check the platform-mounted level to assure
that the scale is level from front to rear.
If the platform is not level, either:
(A) Raise rear of platform by placing shims
underneath the load cell, or
(B) Raise front by placing shims
underneath the hinge on the
anchor bolts (shims provided
with scale).
WASHERS
LOAD CELL
FRONT
MOUNTING FOOT
PLATFORM
REAR
A
WASHERS
Platform must not touch wall or scale will not function
properly. Mark mounting holes on the floor. Drill holes
with 5/16" bit and bolt scale to the floor using two (2) 1/4"
diameter anchor bolts. Make sure your anchor bolts
are properly sized and compatible with your floor material !!
To avoid injury caused by a tipping
carboy, DO NOT use until platform
is bolted to floor.
STEP 3: ANCHORING THE PLATFORM
CAUTION:
STEP 4: ANCHORING THE LOAD CELL
(A) Using Platform as a template, mark floor
to drill Load Cell anchoring hole.
Using this hole,
mark on the floor
for load cell anchoring.
LOAD CELL
ALLIGNMENT
B
B
A
. . .Step 4 continued on page 6
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
WWW.FORCEFLOW.COM / [email protected]
REF: T4\O&M\CARBWIZ\CARBO&M2.tcw (L04.pdf)
S.1.104
W.1.104
(D) Slide leveling washer(s) if needed onto stud.
(E) 1. Insert Load Cell Stud into hole
in the floor.
2. Be certain that the Load
Cell is seated "flush" on the floor.
Position Load Cell so that the cable
runs straight out to either side of the
Platform.
(B) After mark is established on the floor, pivot
Platform out of the way. Centerpunch the mark to
ensure accurate hole location. Drill a 5/16" hole
using an appropriate bit. Drill the hole approximately
1 inch deep.
Cable to exit straight
out on either side of
Platform.
Drill 5/16" diameter
hole, 1 inch deep.
(F) Pivot Platform back into place. Site through the
mounting hole on the platform to ensure that the
"BLACK DOT" on the Load Cell button is
centered in the hole on the platform.
Correct
Incorrect
B
(C) Install stud into threaded hole on
Load Cell. FINGER TIGHTEN ONLY !
STEP 4: ANCHORING THE LOAD CELL cont....
C
E1
D
E2
F
F
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
WWW.FORCEFLOW.COM / [email protected]
REF: T4\O&M\CARBWIZ\CARBO&M3.tcw (L05.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.1.105
S.1.105
To mount additional scales side-by-side, be sure to allow for the frame hinge when determining the
distance between platforms (if minimizing floor area) and repeat Step 1 - 5.
(G) If the "BLACK DOT" on the Load Cell Button is not centered
in the hole on the platform loosen the floor anchor bolts slightly and
adjust platform as needed. Once proper alignment is achieved,
tighten the anchor bolts.
Adjust platform for
proper alignment.
Loosen
"BLACK DOT" on
Load Cell should
be centered in hole
on platform.
STEP 4: ANCHORING THE LOAD CELL cont....
STEP 5: MOUNTING ADDITIONAL SCALES
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
WWW.FORCEFLOW.COM / [email protected]
REF: T4\O&M\CARBWIZ\CARBO&M4.tcw (L06.pdf)
S.1.106
W.1.106
The scale accuracy is plus or minus 1% (2 lbs on 200 lb. Dial,
4 lbs. on 400 lb. Dial) of the actual gross weight. If scale weighs light,
loosen nuts on backstop and move backstop back (away from hinge).
If scale weighs heavy, move backstop forward (toward hinge).
OPERATION
NOTE:
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
WWW.FORCEFLOW.COM / [email protected]
REF: T4\O&M\CARBWIZ\CARBPG7.tcw (L07.pdf)
W.1.108
With carboy opening caps in place, roll a carboy onto the platform until the base
of the carboy touches the platform backstop.
FOR ACCURATE MEASUREMENT, THE CARBOY MUST BE
AGAINST THE BACKSTOP.
1)
Follow "TANK LOAD" Instructions in the Section W.2.103.
2)
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
REF: T4\O&M\INDEX.\Y06.tcw etc (Y06.pdf etc)
SECTION
W.2.000
INDICATOR OPERATION
W.2.101
W.2.102
W.2.103
Keyboard Display Selections
Keyboard Menu - Quick Reference
Tank Load Mode
W.3.000
Code 9081 (Field Calibration)
Calibration of Slotted Platforms
Troubleshooting Tips
Parts List
WIZARD Indicator with CARBOY-SCALE
INDEX
Code 9080 (Scale Set Up)
Code 9082-9083 (Feed Rate Format/Display Units)
Code 9084-9086 (Single or Dual Display/Tank Loading/Printer)
Code 9086 (cont...)-9089 (Time/Date/Calibration/Channels)
Code 4200 & 3256 (Set Point Configuration/4-20mA Output Configuration)
Code 3256 (cont...)
Indicator Wiring & Plumbing
Indicator Installation Instructions
Wizard Component Layout
INSTALLATION CHECK OFF LISTS
W.1.301
W.1.305
INDICATOR INSTALLATION
W.1.201
W.1.202-203
W.1.204
Installation Check-Off List
Installation Start-Up Check-Off List
SET-UP CODES - CUSTOM FORMATTING
W.2.201
W.2.202
W.2.203
W.2.204
W.2.205
W.2.206
MEMU OF DAY-TO-DAY OPERATIONS
W.2.104
W.2.105
W.2.106
W.2.107
W.2.108
MISCELLANEOUS
W.3.101
W.3.102
W.3.301
W.3.401
Low Level Alarm & Date Last Cleared
Clear Amount Used & Set Scale Zero
Set Scale Zero cont... & Allarm Reset
Review Daily Usage & Printing Report
Report (example) & Protocol
YOU
ARE
HERE !
INSTALLATION INSTRUCTIONS
W.1.101
W.1.101-4
W.1.102
W.1.103
W.1.104
W.1.105
W.1.106
W.1.108
Scale Drawing
1 to 4 Channel Configuration Drawing
Installation Drawing
Installation Introduction
Installation Instructions Steps 1 thru 4a
Installation Instructions Steps 4b thru 4f
Installation Instructions Steps 4g thru 5
Scale Operation
LOAD CELL/ULTRASONIC CONNECTIONS
RELAYS
#1
#2
#3
#4
RS485/RS232
#1 #2 #3 #4
DISPLAY ANGLE
ADJUSTMENT (BLUE)
EPROM
RAM
CPU
POWER SUPPLY
POWER IN
CONNECTOR SLEEVE
PLASTIC WASHER
RUBBER GROMMET
CABLE
CONDUIT FITTING
BOX
#1 #2 #3 #4
BOX (FRONT VIEW)
1/4" CORD CONNECTOR, USED FOR:
3
2
4
1
6 SLOTTED PAN HEAD SCREWS.
(TIGHTEN SCREWS EVENLY TO
GET UNIFORM SEAL ON COVER GASKET)
3RD: ATTACH TO CONDUIT
OR CABLE CONNECTOR
FITTING ON BOX
2ND: SCREW CONDUIT
CONNECTOR ONTO
CONDUIT
1ST: SLIP CONDUIT
FITTING BASE
OVER CONDUIT
1/2" CONDUIT CONNECTOR, USED FOR:
5
LOAD CELL CABLE
ULTRASONIC CABLE
POWER
4-20 MA SIGNAL
RELAY WIRING
COMMUNICATIONS)
6
NOTE:
Mount Indicator at "EYE LEVEL"
with the mounting fixtures provided.
FUSE
BOX (BOTTOM VIEW)
1
3
4
2
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
Drawn by: SLP
Date: 09/01/95
Revised: 01/17/01
Scale: NONE
Drawing Number
File: T4\O&M\AWIZMSTR\WIZINDI.tcw (B01.pdf)
29893
INDICATOR WIRING &
PLUMBING INSTRUCTIONS
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
4-20mA WIRING,
LOAD CELL CABLE,
ULTRASONIC CABLE
WIRE/CABLE
CLAMP
WIRE/CABLE
CLAMP
OPTIONAL
AUDIBLE
ALARM
CORD
CONNECTION
CONDUIT
CONNECTION
LOAD CELL/ULTRASONIC (1 & 3)
(1/4" CORD CONNECTION)
4-20mA OUTPUT
(1/2" CONDUIT
CONNECTION)
RS485/RS232
(1/2" CONDUIT
CONNECTION)
110V POWER CONNECTION
(1/2" CONDUIT CONNECTION)
RELAYS (1/2" CONDUIT CONNECTION)
OPTINOAL LOAD CELL
or ULTRASONIC (2 & 4)
(1/4" CORD CONNECTION)
BOX
CONDUIT
CONNECTION
CORD
CONNECTION
W.1.201
W.1.201
TURN OFF MAIN POWER BEFORE CONNECTING !! Use a clean 110 Volt AC (or 220 Volt, if provided)
power line, connected directly to the main power panel at the facility. DO NOT connect any other inductive
loads, relays, etc. to this power line ! Resulting power surges can damage the electronics !!! Use far left
bottom port and connect per following: (NOTE: Use 1/2" conduit connector)
QUESTIONS ? Help Hotline: 1-800-893-6723
When routing load cell cable into box, use a separate 1/2" cord connector per cable. DO NOT
run load cell cable with any other inductive load or power cables !! Run load cell cable up right
hand side of enclosure and use the cable clamps provided to keep cables from laying on the
PC board. Connect load cell wires per following: (NOTE: Use 1/2" conduit connector)
All connectors have a "PLUG IN" feature to assist in connecting wires. Remove the connector
from the board before attaching wires.
Your 4-20 MA signals are internally powered for up to 900 OHMS each. DO NOT use external loop power.
Run 4-20 MA wiring up the right hand side of enclosure using the cableclamps to keep wires off of PC Board.
(NOTE: Use 1/2" conduit connector). If more than one (1) 4-20 MA signal is used, you may use the same conduit
and connector, but DO NOT run 4-20 MA signals with any other power lines, which carry an inductive load..
+ EXCITATION
- EXCITATION
INDICATOR INSTALLATION & WIRING
ALWAYS SHUT OFF MAIN POWER, AS WELL AS POWER TO ANY AUXILIARY EQUIPMENT
THAT WILL BE INSTALLED IN THIS UNIT, BEFORE OPENING FRONT OF CASE !!
DESCRIPTION
POWER IN
PC BOARD
DO NOT CUT LOAD CELL CABLE !! This may void your warranty!! Your WIZARD 4000
Indicator is shipped with the load cells connected and ready to power up. Should you
need to run the load cell cable through conduit, first unplug the connector from the board,
then disconnect wires, and remove by unscrewing cord connectors.
+ EXCITATION
+ SIGNAL
- SIGNAL
- EXCITATION
SHIELD
WIRE COLOR
RED
GREEN
WHITE
BLACK
BRAIDED WIRE
PC BOARD
+ X
+ S
- S
- X
SH
+X4
+S4
- S4
- X4
SH
+X3
+S3
- S3
- X3
SH
+X2
+S2
- S2
- X2
SH
+X1
+S1
- S1
- X1
SH
Scale #4
Scale #1
Scale #2
Scale #3
PC BOARD
DESCRIPTION
+
-
+
-
+
-
+
-
11
12
13
14
+
-
Scale #1
110 Volt
Hot
Ground
Common
3 4-20 MA SIGNALS
2 LOAD CELL CONNECTION
1 POWER HOOK-UP
+
G
C
+ G C
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWIZMSTR\WZININST.tcw (B02.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
Scale #2
Scale #3
Scale #4
POWER IN
PC BOARD
230 Volt
Hot
Ground
Hot
+
G
+
+ G +
230 VOLT AC
110 VOLT AC
W.1.202
Use a separate conduit connector for your serial port communication. DO NOT RUN ANY OTHER
CONDUCTIVE LOAD or power lines with your communicationn wiring. Wire your communications
per the following: (NOTE: Use 1/2" conduit connector).
If it is not possible to mount the indicator at eye level, you may adjust the angle of display by
turning the screw potentiometer clockwise (for down) or counterclockwise (for up). Rotate
1/2 turn at a time until display is clear.
CAUTION should be observed whenever box is open to avoid damage or memory loss by static
electricity. DO NOT touch any of the circuit board, other than the intended contact noted in these
instructions. Carpets, especially can build up static electricity.
If ordered NORMALLY CLOSED:
T G R
RS232
Circuit IS complete until relay is activated.
(Example: Turning OFF a pump)
External apparatus (pumps, valves, alarms, etc) may be ordered either normally open
(N O) or normally closed (N C) These relays are rated at 5 AMPS maximum! To
format your relays, see Set-Up Code #4200 in Chapter "SCALE SET-UP CODES".
If more than one relay is being used, you may use the same conduit connector, but
DO NOT run any other wiring with your relays. (NOTE: Use 1/2" conduit connector).
RS232
RS485 PC BOARD DESCRIPTION
+
-
Positive
Negative
PC BOARD
T
G
R
DESCRIPTION
Transmitted Data (printer data output line)
Signal Ground (signal)
Received Data (printer data input line)
RELAYS
If ordered NORMALLY OPEN:
Circuit is NOT complete until the relay is activated.
(Example: Turning ON a warning light). We
recommend normally open for all "low level"
applications.
Before adjusting the Display Angle Adjustment, make sure of the following:
A Indicator is mounted at "Eye Level". (Display angle is factory set for "eye level")
#1
#2
#3
#4
IN (1)
OUT (1)
IN (2)
OUT (2)
IN (3)
OUT (3)
IN (4)
OUT (4)
Be sure that all power coming into the facility is sufficiently protected for transient lighting strikes and power
surges. Improper protection may void your warranty.
B POWER IS OFF !
+ -
STATIC ELECTRICITY PROTECTION
LIGHTNING ~ SURGE PROTECTION:
6 DISPLAY ANGLE ADJUSTMENTS
5 RELAYS
4 PRINTER COMMUNICATIONS
RS485
QUESTIONS ? Help Hotline: 1-800-893-6723
W.1.203
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWIZMSTR\WZININ2A.tcw (5/27/99) (B03.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
Scale #1 #2 #3 #4
- + - + - + - +
11 12 13 14
SH
-X1
+X1
+S1
-S1
+X2
+S2
-S2
-X2
SH
+X3
+S3
-S3
-X3
SH
+X4
+S4
-S4
-X4
SH
3
6
5
4
1
NOTE: For best viewing, mount indicator at "eye level"
with the mounting fixtures provided.
2
LOAD CELLS
or
ULTRASONIC
SENSORS
FUSE
RELAYS
#1
#2
#3
#4
OUR (1)
IN (1)
OUR (2)
IN (2)
OUT (3)
IN (3)
OUT (4)
IN (4)
6"
13"
WIRE CABLE CLAMP
DISPLAY ANGLE
ADJUSTMENT (Blue)
OPTIONAL
AUDIBLE
ALARM
MOUNTING
FIXTURE
4-20mA OUTPUT
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
Drawn by: SLP
Date: 09/01/95
Revised: 05/27/99
Scale: NONE
Drawing Number
File: T4\O&M\AWZMSTR\WIZINDIA.tcw (B04.pdf) 05/27/99
29892
WIZARD INDICATOR
COMPONENT LAYOUT
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
Scale #2
Scale #3
Scale #4
W.1.204
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
REF: T4\O&M\INDEX.\Y06.tcw etc (Y06.pdf etc)
SECTION
W.2.000
INDICATOR OPERATION
W.2.101
W.2.102
W.2.103
Keyboard Display Selections
Keyboard Menu - Quick Reference
Tank Load Mode
W.3.000
Code 9081 (Field Calibration)
Calibration of Slotted Platforms
Troubleshooting Tips
Parts List
WIZARD Indicator with CARBOY-SCALE
INDEX
Code 9080 (Scale Set Up)
Code 9082-9083 (Feed Rate Format/Display Units)
Code 9084-9086 (Single or Dual Display/Tank Loading/Printer)
Code 9086 (cont...)-9089 (Time/Date/Calibration/Channels)
Code 4200 & 3256 (Set Point Configuration/4-20mA Output Configuration)
Code 3256 (cont...)
Indicator Wiring & Plumbing
Indicator Installation Instructions
Wizard Component Layout
INSTALLATION CHECK OFF LISTS
W.1.301
W.1.305
INDICATOR INSTALLATION
W.1.201
W.1.202-203
W.1.204
Installation Check-Off List
Installation Start-Up Check-Off List
SET-UP CODES - CUSTOM FORMATTING
W.2.201
W.2.202
W.2.203
W.2.204
W.2.205
W.2.206
MEMU OF DAY-TO-DAY OPERATIONS
W.2.104
W.2.105
W.2.106
W.2.107
W.2.108
MISCELLANEOUS
W.3.101
W.3.102
W.3.301
W.3.401
Low Level Alarm & Date Last Cleared
Clear Amount Used & Set Scale Zero
Set Scale Zero cont... & Allarm Reset
Review Daily Usage & Printing Report
Report (example) & Protocol
YOU
ARE
HERE !
INSTALLATION INSTRUCTIONS
W.1.101
W.1.101-4
W.1.102
W.1.103
W.1.104
W.1.105
W.1.106
W.1.108
Scale Drawing
1 to 4 Channel Configuration Drawing
Installation Drawing
Installation Introduction
Installation Instructions Steps 1 thru 4a
Installation Instructions Steps 4b thru 4f
Installation Instructions Steps 4g thru 5
Scale Operation
- Route load cell cable to indicator mounting location, per instructions.
INSTALLATION CHECK-OFF LIST
QUESTIONS ? Help Hotline: 1-800-893-6723
W.1.301
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\CYLWIZ\WZINS150.tcw (K10.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
INSTALL SCALE PLATFORM & LOAD CELL
- Mount at proper location, at "eye level".
MOUNT INDICATOR
- Connect dedicated clean 110 volt AC power line through 1/2" conduit connector.
- Connect load cell cables through 1/4" cord connector.
- Connect 4-20mA signals through 1/2" conduit connector.
- Connect communications through 1/2" conduit connector.
- Connect relays through 1/2" conduit connector.
- Adjust "Display Adjust" if necessary
WIRE INDICATOR - TURN OFF ALL POWER BEFORE WIRING !
- Check all default settings in "Set-Up Codes" and if necessary,
make changes to better fit your application.
NOTE: Any changes to Set-Up Code "9080 SCALE SET-UP"
will require recalibration of your scale.
CUSTOM FORMATTING
- Tighten all six (6) door screws to maintain NEMA 4X seal in box.
- Double check all cord connectors for tight seal.
- Double check all 1/2" conduit connectors for tight seal.
SEAL INDICATOR ENVLOSURE TO MAINTAIN 4X RATING !!!
(Section W.1.101: "Instllation of Scale Platform & Load Cell)
(Section W.1.201 thru W.1.204: Installation and Wiring of Indicator)
(Section W.1.201: Installation and Wiring of Indicator)
(Section W.1.201: Installation and Wiring of Indicator)
(Section W.2.201 thru W.3.301: Custom Formatting Your Scale
POWER-UP: Scale display should read "NET WEIGHT REMAINING". The value will be the tare weight
of your SCALE PLATFORM(s) in "PORTABLE" Tank applications, or your VESSEL & PLATFORM in "FIXED" tank
applications.
Press and verify correct time and date. If incorrect, see SET-UP CODE 9087 (Section W.2.204).
Press until "SET SCALE ZERO" appears
on display. Zero scale as per instructions in Section
W.2.106 "Menu of Day-To-Day Operations". For
future reference, record ZERO FACTOR on a
sticker inside Wizard cover. Refer to Section
W.2.204 "Custom Formatting your Scale",
CODE 9088, to obtain zero factor.
Before LOADING Tank(s), press and wait
until Step 4 "CHANGE TANKS NOW" appears.
See instructions on Tank Load Mode Section W.2.103.
NOTE: If you load tank before reaching the "CHANGE TANK NOW" or the "FILL TANK NOW" step, your
usage data will be inaccurate.
TIME
DATE
TANK
LOAD
"PORTABLE" TANKS - Tank is REPLACED
2
1
START-UP CHECK-OFF LIST
Press until "CLEAR AMOUNT USED" appears on display. Clear the memory per
instructions in Menu of Day-To-Day Operations (Section W.2.105).
MENU
6
Apply pressure to platform to see if indicator responds to changes in weight.
3
Review SET-UP CODES, especially 9082, 9084, 9085 and 9089 (Starting at Section W.2.201)
4
QUESTIONS ? Help Hotline: 1-800-893-6723
W.1.305
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\CHKOFF.tcw (J10.pdf) 01/24/02 BD
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
MENU
With EMPTY tank on platform, press
until scale indicator reads "ENTER TARE". Zero scale as
per instructions in Section W.2.106 "Menu of Day-To-Day
Operations". For future reference, record ZERO FACTOR
on a sticker inside Wizard cover. Refer to Section W.2.204
"Custom Formatting your Scale", CODE 9088, to obtain
zero factor.
"FIXED" TANKS - Tank is REFILLED
MENU
"PORTABLE" TANK - Tank is REPLACED
"FIXED" TANK - Tank is REFILLED
Before FILLING Tank(s), press and proceed
as directed. Refer to "Operating Instructions",
Section W.2.103 TANK LOAD MODE.
5
5
7
7
TANK
LOAD
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
REF: T4\O&M\INDEX.\Y06.tcw etc (Y06.pdf etc)
SECTION
W.2.000
INDICATOR OPERATION
W.2.101
W.2.102
W.2.103
Keyboard Display Selections
Keyboard Menu - Quick Reference
Tank Load Mode
W.3.000
Code 9081 (Field Calibration)
Calibration of Slotted Platforms
Troubleshooting Tips
Parts List
WIZARD Indicator with CARBOY-SCALE
INDEX
Code 9080 (Scale Set Up)
Code 9082-9083 (Feed Rate Format/Display Units)
Code 9084-9086 (Single or Dual Display/Tank Loading/Printer)
Code 9086 (cont...)-9089 (Time/Date/Calibration/Channels)
Code 4200 & 3256 (Set Point Configuration/4-20mA Output Configuration)
Code 3256 (cont...)
Indicator Wiring & Plumbing
Indicator Installation Instructions
Wizard Component Layout
INSTALLATION CHECK OFF LISTS
W.1.301
W.1.305
INDICATOR INSTALLATION
W.1.201
W.1.202-203
W.1.204
Installation Check-Off List
Installation Start-Up Check-Off List
SET-UP CODES - CUSTOM FORMATTING
W.2.201
W.2.202
W.2.203
W.2.204
W.2.205
W.2.206
MEMU OF DAY-TO-DAY OPERATIONS
W.2.104
W.2.105
W.2.106
W.2.107
W.2.108
MISCELLANEOUS
W.3.101
W.3.102
W.3.301
W.3.401
Low Level Alarm & Date Last Cleared
Clear Amount Used & Set Scale Zero
Set Scale Zero cont... & Allarm Reset
Review Daily Usage & Printing Report
Report (example) & Protocol
YOU
ARE
HERE !
INSTALLATION INSTRUCTIONS
W.1.101
W.1.101-4
W.1.102
W.1.103
W.1.104
W.1.105
W.1.106
W.1.108
Scale Drawing
1 to 4 Channel Configuration Drawing
Installation Drawing
Installation Introduction
Installation Instructions Steps 1 thru 4a
Installation Instructions Steps 4b thru 4f
Installation Instructions Steps 4g thru 5
Scale Operation
0 1 2 3 4 5 6 7 8 9
SCALE
SELECT
DISPLAY
SELECT TOTALS
TANK
LOAD
MENU
MENU
ENTER
AMOUNT USED
SCALE 1 = 7687 LB
SCALE 2 = 6521 LB
MENU MENU
DEL
DEL
TANK
LOAD
SCALE
SELECT
ENTER
%
TOTALS
Toggles through a
multi-function display
for each scale.
Toggles through a
multi-function display
for the totals of all scales.
Toggles
Between
Individual
Scales
Scrolls
Back
Through
the Menu
OPERATIONS MENU
LOW LEVEL ALARM........................
DATE LAST CLEARED....................
CLEAR AMOUNT USED..................
SET SCALE ZERO/ENTER TARE..
ALARM RESET................................
REVIEW DAILY USE.......................
FUNCTION DESCRIPTION
Entering of low level setpoint
Date the "amount used" was last reset
Clears the "amount used" display
Zero's the display
Resets the low level alarm (if set in
the latching mode)
Reviews past 10 days usage
Backspace
or Escape
Menu Operations
Data Entry
and Menu
Function
Access
"Time" and
"Date"
Displays
Percent
of Full
Reset Button (Resets
screen to opening menu
in case of entry error)
Single or Dual
Display (16
Characters
per Line Screen)
Total Remaining
Total Used
Total Feed Rate
Net Remaining
Amount Used
Average Feed Rate
Days Until Empty
Daily Usage
If applicable:
Tare Weight
Gross Weight
Scrolls
Forward
Through
the Menu
Loading
New Tanks
or Chemicals
Numeric
Data Entry
Key Pad
DISPLAY
SELECT
TIME
DATE
TIME
DATE
%
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
Drawn by: SLP
Date: 09/01/95
Revised: 11/01/99
Scale: NONE
Drawing Number
File: T4\O&M\AWZMSTR\WZBUTTON.tcw (B05.pdf) 10/20/99
29887
WIZ
INDICATOR BUTTON
FUNCTIONS LIST FOR
WIZARD INDICATOR
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.101
KEYBOARD & MENU FUNCTIONS
QUICK REFERENCE GUIDE
QUESTIONS ? Help Hotline: 1-800-893-6723
W.2.102
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZKEYBD2.tcw (B06.pdf) 10/20/99
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
Scrolls forward through individual scales.
SCALE SELECT
Toggles through a multi-function display for each scale in the
following decending order:
DISPLAY SELECT
NET REMAINING............
AMOUNT USED..............
AVERAGE FEED RATE..
DAYS UNTIL EMPTY......
DAILY USAGE................
If applicable:
TARE WEIGHT...............
GROSS WEIGHT...........
Chemical remaining in tank or cylinder
A running total of net chemical used since last reset
Current chemical feed rate in lbs. or gallons per day
Days until empty at the current feed rate
Previous day's total chemical usage
Tank tare weight
Tank tare plus chemical weight
Toggles through a multi-function display for the totals of all scales,
in the following descending order:
TOTALS
TOTAL REMAINING.........
TOTAL USED...................
TOTAL FEED RATE.........
Chemical remaining in all tanks
Chemical used in all tanks
Chemical feed rate of all tanks
Displays NET REMAINING as a PERCENTAGE of full.
%
Time and Date
TIME DATE
Loading new tanks or chemicals and entering tank tare weights.
TANK LOAD
Scroll through a list of day-to-day operations in DESCENDING order.
See Section "OPERATING INSTRUCTIONS", under
"MENU OF DAY-TO-DAY OPERATIONS":
MENU DOWN
LOW LEVEL ALARM...........
DATE LAST CLEARED.......
CLEAR AMOUNT USED.....
SET SCALE ZERO/TARE...
ALARM RESET...................
REVIEW DAILY USE..........
PRINT.................................
Entering of low level set point values
Date the "amount used" display was last cleared
Clears the "amount used" display and "daily usage" display
Zero's the display
Resetsthe low level alarm (if set in the latching mode)
Stores the last 10 days Daily Usage
Outputs date via serial port to a printer
These are the functions that are used on a day-to-day basis.
DO NOT UNLOAD or LOAD tanks until "CHANGE TANKS NOW, THEN
PRESS ENTER" appears on the display. If you load or unload tanks
before reaching this step, the "amount used" and "daily usage" displays
will be incorrect.
It also allows you to enter the tare weight(s) of your tanks if you choose "Manual" tank load mode, or load the
net weight of a cylinder if you chose the "Auto" tank load mode. (See Code Set-up 9085)
Allows you to load new tanks without adversly affecting
the "AMOUNT USED" and "DAILY USAGE" displays.
MENU
Press to enter the tank load mode.
Remove empty tanks and place new tank(s) onto the scale
then press
SCALE #2 TANK #1
TARE = XXXX
NET REMAINING
SCALE 1 = XXXX
Enter the scale NUMBER that you want to load/unload tanks.
This "freezes" or "holds" the AMOUNT USED and DAILY
USAGE displays until feeding resumes).
1
2
ENTER SCALE #
1 THRU 2 X
....If you chose "AUTO" the WIZARD automatically loads the
net weight and goes into the weighing mode (skip Step 6).
ENTER
CHANGE TANKS NOW
THEN PRESS ENTER
WAIT
TARE MODE
*AUTO MANUAL
Press or then
Press to select which method, then press
MANUAL Mode: Requires that you enter tare weight of EACH tank on
EACH scale. (Example: Scale #2, tare weight of TANK #1, then
TANK #2, etc). After entering the tare weights of all your tanks, the
WIZARD 4000 automatically adds them up and subtracts them from
the gross weight.
ENTER
ENTER
TANK
LOAD
Step 6
Digital Display
Action Required - Press "ENTER" after completing each step.
Step 2
Step 4
Step 5
Step 3
Step 1
Wait until this clears to continue.
TANK
LOAD
....If you chose "MANUAL" you will manually enter tank
tare weight in Step 6.
....If MANUAL chosen above in Step 3...
Use "MANUAL" for PARTIALLY FULL containers.
Use "AUTO" for FULL containers.
TANK LOAD MODE
Fill your tank with chemicals, then press
FILL TANK NOW
THEN PRESS ENTER
ENTER
Step 7
"PORTABLE" Tank Applications (Follow Steps 1 thru 6 only)
(such as Ton Containers, Drums and Cylinders)
"FIXED" Tank Applications (Follow Steps 1, 2 and 7 only)
(such as Chem-Scale, Hoppers, Powercells and Ultrasonic)
Skip to STEP 7 in "FIXED" Tank Applications.
QUESTIONS ? Help Hotline: 1-800-893-6723
W.2.103
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZDAY1B.tcw 11/99 (B07.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
REF: T4\O&M\INDEX.\Y06.tcw etc (Y06.pdf etc)
SECTION
W.2.000
INDICATOR OPERATION
W.2.101
W.2.102
W.2.103
Keyboard Display Selections
Keyboard Menu - Quick Reference
Tank Load Mode
W.3.000
Code 9081 (Field Calibration)
Calibration of Slotted Platforms
Troubleshooting Tips
Parts List
WIZARD Indicator with CARBOY-SCALE
INDEX
Code 9080 (Scale Set Up)
Code 9082-9083 (Feed Rate Format/Display Units)
Code 9084-9086 (Single or Dual Display/Tank Loading/Printer)
Code 9086 (cont...)-9089 (Time/Date/Calibration/Channels)
Code 4200 & 3256 (Set Point Configuration/4-20mA Output Configuration)
Code 3256 (cont...)
Indicator Wiring & Plumbing
Indicator Installation Instructions
Wizard Component Layout
INSTALLATION CHECK OFF LISTS
W.1.301
W.1.305
INDICATOR INSTALLATION
W.1.201
W.1.202-203
W.1.204
Installation Check-Off List
Installation Start-Up Check-Off List
SET-UP CODES - CUSTOM FORMATTING
W.2.201
W.2.202
W.2.203
W.2.204
W.2.205
W.2.206
MEMU OF DAY-TO-DAY OPERATIONS
W.2.104
W.2.105
W.2.106
W.2.107
W.2.108
MISCELLANEOUS
W.3.101
W.3.102
W.3.301
W.3.401
Low Level Alarm & Date Last Cleared
Clear Amount Used & Set Scale Zero
Set Scale Zero cont... & Allarm Reset
Review Daily Usage & Printing Report
Report (example) & Protocol
YOU
ARE
HERE !
INSTALLATION INSTRUCTIONS
W.1.101
W.1.101-4
W.1.102
W.1.103
W.1.104
W.1.105
W.1.106
W.1.108
Scale Drawing
1 to 4 Channel Configuration Drawing
Installation Drawing
Installation Introduction
Installation Instructions Steps 1 thru 4a
Installation Instructions Steps 4b thru 4f
Installation Instructions Steps 4g thru 5
Scale Operation
This function allows the user to find out the last time and date the
"Amount Used" display was cleared or reset for each scale.
NOTE: You must have purchased the low level alarm option and your alarm must be
enabled under Code Set-Up #4200 for this function to operate. (See Chapter "SET-UP CODES")
LOW LEVEL ALARM
SCALE 1 = X LB.
Displays DATE and TIME "AMOUNT USED" function was last
cleared is displayed for 8 seconds
Enter low level VALUE via key pad for SCALE 2...
then press (Example: Low level set point 150 lbs)
Enter low level VALUE via key pad for SCALE 1...
then press (Example: Low level set point 100 lbs)
ENTER
ENTER
LOW LEVEL ALARM
THEN PRESS ENTER
Allows you to enter your low level set point values for the optional low level alarm. For this function to work properly,
the alarm must be "enabled" under the Set-up Code #4200. Be sure to read this set-up code thoroughly before
using this function. When a low level condition exists, your display will continuously flash "Low Level Scale #_____"
and the optional 5 AMP relay will be activated. (See Chapter "SET-UP CODES")
LOW LEVEL ALARM
SCALE 2 = X LB.
DATE LAST CLEARED
THEN PRESS ENTER
ENTER SCALE #
1 THRU 2 X
SCALE 2 CLEARED
09/15/95 22:15
(or 1 thru 4)
Press to continue.
Press to continue.
Enter which scale NUMBER... then press
ENTER
ENTER
Digital Display
Action Required - Press "ENTER" after completing each step.
Action Required - Press "ENTER" after completing each step.
Digital Display
Step 1
Step 2
Step 3
Step 1
Step 2
Step 3
This menu contains a list of operations that are used on a frequent basis. Each menu item is followed by
"THEN PRESS ENTER" and has step-by-step operating instructions.
DATE LAST CLEARED
LOW LEVEL ALARM
MENU OF DAY-TO-DAY OPERATIONS
QUESTIONS ? Help Hotline: 1-800-893-6723
W.2.104
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZDAY2.tcw (B08.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
Enter for YES...
Enter for NO
Enter to clear all scales....or (if "1" entered, skip Step 3)
Enter to clear individual scales (go to Step 3)
Clears or resets the "AMOUNT USED" and
"DAILY USAGE" display to zero.
ARE YOU SURE?
1 = Y 0 = N X
ENTER SCALE #
1 THRU 4 X
Enter for YES....or
Enter for NO
Press to continue.
If you chose INDIVIDUAL scales....
Allows the user re-zero the display if it has drifted or changed, OR enter
the TARE WEIGHT of the tank.
SET SCALE ZERO
THEN PRESS ENTER
ENTER
Press to continue.
1
0
1
0
0
1
ENTER
Step 1
Step 2
Step 3
Step 4
Step 1
Step 2
Step 3
Digital Display
Action Required - Press "ENTER" after completing each step.
Digital Display
Action Required - Press "ENTER" after completing each step.
SET SCALE ZERO / TARE
CLEAR AMOUNT USED
PORTABLE TANK APPLICATIONS . . . .
FIXED TANK APPLICATIONS . . . . .
Enter the NUMBER of the scale you want to enter a Tare Weight.
Choose scale 1, 2, 3 or 4
ARE YOU SURE?
1 = Y 0 = N X
ENTER SCALE #
1 THRU 4 X
Enter for YES....or
Enter for NO
ZERO / TARE
THEN PRESS ENTER
Press to continue.
0
1
ENTER
Step 1
Step 2
Step 3
Digital Display
Action Required - Press "ENTER" after completing each step.
Enter the NUMBER of the scale you want to enter a Tare Weight.
Choose scale 1, 2, 3 or 4
Enter the NUMBER of the scale you want to enter a Tare Weight.
Choose scale 1, 2, 3 or 4
CLEAR ALL SCALES
1 = Y 0 = N X
CLEAR AMOUNT USED
THEN PRESS ENTER
ARE YOU SURE?
1 = Y 0 = N X
ENTER SCALE #
1 THRU 4 X
QUESTIONS ? Help Hotline: 1-800-893-6723
W.2.105
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZDAY3A.tcw 06/01/99 (B09.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
Re-sets the optional low level alarm, if your alarm is set in the latching mode.
NOTE: You must correct the low level condition (choose the applicable remedy):
Replace the CL2 or SO2 tank(s)
Fill the tank
before resetting the alarm. Silence the optional internal audible alarm by
pressing
ALARM RESET
THEN PRESS ENTER
ENTER TANK
TARE = XXXX
Press to reset.
Enter for YES....or
Enter for NO
DELETE
Continued . . .
IS TANK EMPTY ?
1 = Y O = N
0
1
ENTER
Step 1
Action Required - Press "ENTER" after completing each step.
Digital Display
Step 4
Step 5
Digital Display
Action Required - Press "ENTER" after completing each step.
Portable Tank:
Stationary Tank/Hopper:
ALARM RESET
SET SCALE ZERO / TARE
FIXED TANK APPLICATIONS cont . . . .
Using the Numeric Keys, input the TARE WEIGHT
(the weight of the empty tank and any other accessories)
QUESTIONS ? Help Hotline: 1-800-893-6723
W.2.106
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZDAY3B.tcw 11/99 (B10.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
The print function allows you to down load display functions to a printer or other aparatus on a
manual or automatic basis. If you chose "Auto Print" under Code Set-Up 9086, the entire report will be printed.
DELETE
Digital Display
Action Required - Press "ENTER" after completing each step.
Press to continue.
Step 2
ENTER SCALE #
1 THRU 2 XXXX
Enter the number of the scale you want to review.
Step 3
SCALE 1 USAGE;
12/25/96 164
ENTER
Allows the user to review past 10 days chemical usage.
Digital Display
Action Required - Press "ENTER" after completing each step.
Step 1
REVIEW DAILY USAGE
THEN PRESS ENTER
Chemical usage on that particular date. Press
for next date, or to escape.
Step 1
PRINT
PRESS ENTER
Press to continue.
ENTER
ENTER
REVIEW DAILY USAGE
PRINT
QUESTIONS ? Help Hotline: 1-800-893-6723
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZDAY4A.tcw 11/99 (B11.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.107
REPORT (example of "REPORT")
PROTOCOL
8/ 15/ 0 14:21
NET REMAINING
SCALE 1 1950 LB
SCALE 1832 LB
---------------------
TOTAL = 3782 LB
AVG FEED RATE
SCALE 1 0 PD
SCALE 2 288 PD
----------------------
TOTAL = 288 PD
Net Chemical Remaining......
in the Tank
................Average Chemical Feed
Rate in Lbs/Days or Lbs/Hr
.....................Time and Date of Report
Protocol for other communication devices.
Baud Rate: 600, 1200, 2400, 4800 or 9600
Bits: 8 Bit, 1 Start Bit, 1 Stop Bit, No Parity
Hand Shake: None
Ready . . .
QUESTIONS ? Help Hotline: 1-800-893-6723
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZPRINTA.tcw 10/20/99 (B12.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.108
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
REF: T4\O&M\INDEX.\Y06.tcw etc (Y06.pdf etc)
SECTION
W.2.000
INDICATOR OPERATION
W.2.101
W.2.102
W.2.103
Keyboard Display Selections
Keyboard Menu - Quick Reference
Tank Load Mode
W.3.000
Code 9081 (Field Calibration)
Calibration of Slotted Platforms
Troubleshooting Tips
Parts List
WIZARD Indicator with CARBOY-SCALE
INDEX
Code 9080 (Scale Set Up)
Code 9082-9083 (Feed Rate Format/Display Units)
Code 9084-9086 (Single or Dual Display/Tank Loading/Printer)
Code 9086 (cont...)-9089 (Time/Date/Calibration/Channels)
Code 4200 & 3256 (Set Point Configuration/4-20mA Output Configuration)
Code 3256 (cont...)
Indicator Wiring & Plumbing
Indicator Installation Instructions
Wizard Component Layout
INSTALLATION CHECK OFF LISTS
W.1.301
W.1.305
INDICATOR INSTALLATION
W.1.201
W.1.202-203
W.1.204
Installation Check-Off List
Installation Start-Up Check-Off List
SET-UP CODES - CUSTOM FORMATTING
W.2.201
W.2.202
W.2.203
W.2.204
W.2.205
W.2.206
MEMU OF DAY-TO-DAY OPERATIONS
W.2.104
W.2.105
W.2.106
W.2.107
W.2.108
MISCELLANEOUS
W.3.101
W.3.102
W.3.301
W.3.401
Low Level Alarm & Date Last Cleared
Clear Amount Used & Set Scale Zero
Set Scale Zero cont... & Allarm Reset
Review Daily Usage & Printing Report
Report (example) & Protocol
YOU
ARE
HERE !
INSTALLATION INSTRUCTIONS
W.1.101
W.1.101-4
W.1.102
W.1.103
W.1.104
W.1.105
W.1.106
W.1.108
Scale Drawing
1 to 4 Channel Configuration Drawing
Installation Drawing
Installation Introduction
Installation Instructions Steps 1 thru 4a
Installation Instructions Steps 4b thru 4f
Installation Instructions Steps 4g thru 5
Scale Operation
This function allows you to format your display by choosing various parameters like "lbs" or "kilos"; how many fixed zeros;
number of decimal places; your increments or "county by"; total number of digits or "resolution", and your capacity.
These Set-Up Codes allow you to custom format your scale for your specific application. They may be accessed when
initially installing your scale, but otherwise, very infrequently. You may change your default setting by entering the
4-digit numeric password and then pressing "ENTER". You may NOT access Set-Up codes while in the "MENU". You
must press delete to escape the Menu.
How many numbers right of the decimal point. Enter "O" or "1"
Example: 1 decimal place = 486.3 pounds.
NOTE: Most applications over 2,000 lbs. will use "O" decimal places.
NUMBER OF
DECIMALS _______
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
All Set-Up Codes have been factory set for your specific application and your
scale(s) has been calibrated.
Model Number of Scale/Sensor: ___________
Quantity of Scale Platforms: ________ (if applicable)
If any of the scale Set-Up functions are changed, your scale must be recalibrated.
WEIGHT UNITS
*LBS or KGS _______
Choose to read either "metric" or "imperial" units. Use arrow keys to select.
FIXED ZEROS ______
This function is displayed only if "0" decimal places is selected. This
represents how many "dead" zeros you want on your display. Enter "0" or "1".
Example: 1 fixed zero = 26,340
NOTE: Most applications under 20,000 lbs. will have "0" fixed zeros.
1, 2, OR 5
COUNT BY _______
Establishes the minimum increments of the display. Enter "1", "2" or "5".
Example: "1" = 1 lb. increments. "5" = 5 lb. increments. Choose 1, 2 or 5.
RESOLUTION
DIGITS = ________
Establishes the number of displayed increments or total "counts".
Choices: 1,000, 2,000, 3,000, 4,000, 8,000 or 12,000. Scroll the Menu Keys
until the desired resolution displays, then press ENTER.
NOTE: This number is not the total "capacity". Capacity will be the
automatic result of the "count by" and "resolution" entry.
CAPACITY _________
BY _________
Displays the result of the above selections. Push ENTER to accept.
SET-UP CODES
NOTE:
9080 SCALE SET-UP
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZSETUP1.tcw (B13.pdf)
QUESTIONS ? Help Hotline: 1-800-893-6723
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.201
(See Chapter "FIELD CALIBRATION, SET-UP CODE 9081")
Allows you to choose between "lbs per day" ("gallons per day") and "lbs. per hour" ("gallons per hour") and allows you
to set your sample time or "update period" for your feed rate function.
Use ARROWS to select:
Rate Update Period In: MIN = Minutes
HOUR = Hours
PERIOD BASE
____MIN ____ HOUR
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
In general, if your feed rates are fairly constant on a daily basis, the longer you set your update period for, the more
accurate your feed rate function will be. However, if your feed rate varies from hour to hour or minute to mintue, choose
a shorter update period to give you a more accurate feed rate at a point in time. You may have to experiment with
different update periods to get the desired result for your application.
*IMPORTANT NOTE: Setting your "Update Period"
For certain applications with very low feed rates (less than 2% of full scale capacity per day), low sample times will not
give you accurate readings.
RATE TIME BASE
____PPH ____ PPD
____KPH ____ KPD
This function allows you to choose your display to read in weight or gallons. If you choose gallons, you must enter
the specific gravity of the chemical being fed.
UPDATE PERIOD
HOURS = _________
Use ARROWS to select update period:
Choice if HOURS: 2, 4, 6, 8, 12 Hours
Choice if MINUTES: 2, 5, 10, 20, 30, 60 Minutes
NOTE: See IMPORTANT NOTE above "Setting your Update Period".
DISPLAY UNITS
*LBS. GAL
*KGS GAL
Use ARROWS to select WEIGHT (Lbs/Kgs) or VOLUME (Gallons).
SPECIFIC GRAVITY
SCALE 1 = X.XXX
If you choose VOLUME, enter the specific gravity of material being fed.
NET REMAINING
SCALE 1 = X.XXX
Displays the result of the above selections.
Digital Display / Default (in red)
Action Required - Press "ENTER" after completing each step
Use ARROWS to select: (If Lbs chosen) (If Kgs chosen)
If calibrated in LBS/KGS: PPH = Lbs. per HOUR KPH = Kgs. per HOUR
PPD = Lbs. per DAY KPD = Kgs. per DAY
Or if calibrated in GALLONS: GPH = Gallons per HOUR
GPD = Gallons per DAY
Use a Longer
Update Period
9083 DISPLAY UNITS
9082 FEED RATE FORMAT
9081 FIELD CALIBRATION
HIGH FEED
CONSTANT
LOW FEED (less than 2% capacity/day)
N/A (Not Accurate)
Use a Short
Update Period
Use a Short or
Long Update Period
FLUCTUATING
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZSETUP2.tcw (B14.pdf)
QUESTIONS ? Help Hotline: 1-800-893-6723
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.202
For applications: This allows the user to either manually enter tank tare weights, or to automatically
load full containers of 2,000 lbs.net weight. However, if container is partially empty, or if you are only loading one
tank on a multiple tank scale, you must use "MANUAL" mode.
For applications: You must use "MANUAL" mode.
Will be displayed if AUTO was chosen above.
Use key pad to enter the net contents of containers.
NET WEIGHT EXAMPLES
2000 lb. = Ton Containers (USA)
150 lb. = 150 lb. Cylinders (USA)
907 kg. = Canadian Ton Containers
1000 kg. = Metric Ton Containers
AUTO NET WT / LB (/KG)
WEIGHT = _______
TARE MODE
___AUTO ___MANUAL
Allows you to format your communications baud rate; print format and whether you want to engage the
datalogging (auto print) function.
Do you want the sceen to automatically alternate between diplays?
Choices: "1" = YES "0" = NO
BTM LINE FEEDS
NUMBER = ______
Enter the number of SPACES at the BOTTOM fo your printout.
Choices: 1 to 100.
Allows display to alternate between scale displays automatically or manually as well as displaying 1 or 2 scales at a time.
USE DEL , ENTER
BAUD = ______
Use ARROW KEY to select your BAUD RATE:
Choices: 300, 600, 1200, 2400, 4800, 9600.
TOP LINE FEEDS
NUMBER = ______
Enter the number of SPACES at the TOP of your printout.
Choices: 1 to 100
Use ARROW KEY to select:
Automatically load the net contents of containers
Manually enter the tare weight of your tanks.
NOTE: "AUTO" applies to CL2 & SO2 tanks only
(and on some Drumm-Scale applications)
AUTO =
MANUAL =
9086 FORMAT PRINTER PORT (RS232 / RS485)
9084 SINGLE or DUAL DISPLAY
9085 TANK LOADING MODE
AUTO SCAN ?
1=Y 0=N
Use ARROW KEY to select:
SINGLE = 1 scale displayed
DUAL = 2 scales displayed
NOTE: Single channel scale CANNOT Auto Scan and will only use
single scale display.
100% / AUTO LOAD
SCALE 1 XXX
Enter the value that represents a full tank.
DISPLAY FORMAT
*SINGLE DUAL
Cl2 & SO2
ALL OTHER CHEMICAL FEED, HOPPER & TANK
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZSET3C.tcw 11/99 (B15.pdf)
QUESTIONS ? Help Hotline: 1-800-893-6723
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.203
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
AUTO PRINT ?
1 = Y 0 = N _____
Do you want to engage the AUTO PRINT (Datalogging) function?
Choices: "1" = YES "0" = NO (by engaging this function, the
WIZARD 4000 will automatically download all display functions
and totals on an hourly or daily basis).
AUTO PRINT TIME
___HOUR ___DAY
Use ARROW KEY to select AUTO PRINTING once per HOUR or
once per DAY.
9086 FORMAT PRINTER PORT (RS232 / RS485) continued .....
XX
XX
XX
XX
XX
Enter the YEAR (last 2 digits only. Example: 96 = 1996)
Enter the MONTH (2 digits. Example: 09 = Sept)
Enter the DAY (2 digits. Example: 02 = 2nd)
Enter the HOUR (military time. Example: 14 = 2pm)
Enter the MINUTE (2 digits. Example: 05 = 5 minutes)
Digital Display / Default (in red)
Action Required - Press "ENTER" after completing each step
Sets time and date
YEAR
MONTH
DAY
HOUR
MINUTE
9087 TIME AND DATE
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
The number displayed should correspond to the calibration factor
recorded on the calibration data inside the front cover. To restore
original factory value, use numeric keypad to enter correct value.
9088 CALIBRATION FACTOR
Allows you to verify Calibration Factor against original factory Calibration Factor.
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
9089 CHANNEL IDENTIFICATION NUMBERS
Allows you to assign an Identification Number (from 1 to 99) to each scale.
CHANNEL 1 SCALE
NUMBER = XX
The number displayed should correspond to the zero factor recorded on the
calibration data inside the front cover. To restore orginal factory value, use
numeric keypad to enter correct value.
Factory setting is 15. DO NOT CHANGE.
Factory setting is 47. DO NOT CHANGE.
SCALE 1 FACTOR
NUMBER = XXXXXX
SCALE 1 MOT CTS
NUMBER = 15
SCALE 1 ZERO
NUMBER = XXXX
SCALE 1 FILTER
NUMBER = 47
Use the numberic keypad to enter any number from 1 to 99 to
identify each scale.
NOTE: Repeat for each additional scale.
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZSET3D.tcw 05/27/99 (B16.pdf)
If 'YES", you will see the following:
QUESTIONS ? Help Hotline: 1-800-893-6723
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.204
This option requires a special access code, which will be provided when this option is supplied.
For Scale ONE. Do you want your alarm latching?
#1 SET POINT LATCHED
1 = Y 0 = N ______
#1 SET POINT ENABLED
1 = Y 0 = N ______
For Scale ONE. Do you want to turn the low level alarm ON or OFF.
Choice: "1" = ON "0" = OFF
Digital Display / Default (in red)
Action Required - Press "ENTER" after completing each step
Enter the PASSWORD to continue. Required to access this option.
(Optional Accessory)
THIS UNIT CONTAINS:
4200 SET POINT CONFIGURATION
Choose: "1" =
Choose: "0" =
NOTE: Questions repeat for each additional scale.
LATCHING (alarm condition exists until
operator acknowledges the alarm by re-setting in the menu)
NON-LATCHING (alarm condition exists until tank is refilled)
ENTER CODE
NUMBER = ______
Dry Contact Relays
Solid State Relay
N/O (Normally Open)
N/C (Normally Closed)
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZSTUP4A.tcw (3/05/02) (B17.pdf)
QUESTIONS ? Help Hotline: 1-800-893-6723
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.205
For ALL Scales: Do you want to invert the operation of the relays?
INVERT RELAYS ?
1 = Y 0 = N ______
Choose "1" =
The relay will be actuated in a NON-ALARM condition.
If an ALARM condition occurs, relay is de-activated.
EXAMPLE:
If "INVERTED RELAY" is selected, a Normally
Closed relay will be actuated (OPENED contact)
in NON-ALARM status. During an ALARM
situation, relay is de-actuated (CLOSED contact).
Choose "0" =
The relay will be actuated when an ALARM situation
is encountered.
EXAMPLE:
If "INVERTED RELAY" is NOT selected, a Normally
Closed relay will NOT be actuated (CLOSED contact)
in NON-ALARM status. During an ALARM
situation, relay is actuated (OPEN contact).
This feature allows configuration of FAIL SAFE alarm
relay contacts.
PORT 1 RANGE FS
NET WT = ________
Enter FULL SCALE range for the scale on PORT 1
NOTE: If you choose "NET WEIGHT": We recommend that you set
your full scale range equal to your scale capacity.
If you choose "RATE": Set your full scale equal to the maximum
feed rate which you expect to see on that scale.
Use ARROW KEY to choose (for the scale on PORT 1), either:
RATE (Rate of Feed) or
NET WT (Net Weight)
___RATE ___NT WT
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZSETUP5.tcw 11/99 (B18.pdf)
QUESTIONS ? Help Hotline: 1-800-893-6723
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.2.206
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
If you have chosen the analog output option, this allows you to select either net weight or feed rate as
your output. This option requires a special access code.
TRANSMIT SCALE
*SINGLE TOTAL
This allows you to choose between transmitting the TOTAL of ALL
SCALES, or transmitting INDIVIDUAL SCALES (when "total" is
chosen, transmitting is ALWAYS done on PORT 1). Use
ARROW KEY to select, then ENTER.
HOW MANY PORTS ?
1 thru 4 _______
How many scales will have transmitters?
Choices: "1", "2", "3" or "4"
PORT 1 SCALE
NUMBER = ______
Which scale will have PORT 1?
NOTE: We recommend using Port 1 for Scale 1,
Port 2 for Scale 2, etc.
ENTER CODE
NUMBER = ______
Enter the PASSWORD to continue. Required to access this option.
(Optional Accessory)
4-20 MA OUTPUT?
1 = Y 0 = N ______
To activate the 4-20 MA option.
Choices: "1" = YES "0" = NO
3256 4-20 MA ANALOG OUTPUT CONFIGURATION
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
REF: T4\O&M\INDEX.\Y06.tcw etc (Y06.pdf etc)
SECTION
W.2.000
INDICATOR OPERATION
W.2.101
W.2.102
W.2.103
Keyboard Display Selections
Keyboard Menu - Quick Reference
Tank Load Mode
W.3.000
Code 9081 (Field Calibration)
Calibration of Slotted Platforms
Troubleshooting Tips
Parts List
WIZARD Indicator with CARBOY-SCALE
INDEX
Code 9080 (Scale Set Up)
Code 9082-9083 (Feed Rate Format/Display Units)
Code 9084-9086 (Single or Dual Display/Tank Loading/Printer)
Code 9086 (cont...)-9089 (Time/Date/Calibration/Channels)
Code 4200 & 3256 (Set Point Configuration/4-20mA Output Configuration)
Code 3256 (cont...)
Indicator Wiring & Plumbing
Indicator Installation Instructions
Wizard Component Layout
INSTALLATION CHECK OFF LISTS
W.1.301
W.1.305
INDICATOR INSTALLATION
W.1.201
W.1.202-203
W.1.204
Installation Check-Off List
Installation Start-Up Check-Off List
SET-UP CODES - CUSTOM FORMATTING
W.2.201
W.2.202
W.2.203
W.2.204
W.2.205
W.2.206
MEMU OF DAY-TO-DAY OPERATIONS
W.2.104
W.2.105
W.2.106
W.2.107
W.2.108
MISCELLANEOUS
W.3.101
W.3.102
W.3.301
W.3.401
Low Level Alarm & Date Last Cleared
Clear Amount Used & Set Scale Zero
Set Scale Zero cont... & Allarm Reset
Review Daily Usage & Printing Report
Report (example) & Protocol
YOU
ARE
HERE !
INSTALLATION INSTRUCTIONS
W.1.101
W.1.101-4
W.1.102
W.1.103
W.1.104
W.1.105
W.1.106
W.1.108
Scale Drawing
1 to 4 Channel Configuration Drawing
Installation Drawing
Installation Introduction
Installation Instructions Steps 1 thru 4a
Installation Instructions Steps 4b thru 4f
Installation Instructions Steps 4g thru 5
Scale Operation
Your scale has been factory calibrated. This function allows you to field calibrate your scales by setting
the zero and span for each scale with known weights.
Enter which scale you want to calibrate. Choice "1", "2", 3" or "4"
ENTER SCALE
NUMBER X
Action Required - Press "ENTER" after completing each step
Digital Display / Default (in red)
NOTE:
DEL FACTORY CAL ?
1 = Y 0 = N X
Do you want to DELETE THE FACTORY CALIBRATION ?
Enter "1" for YES, or "0" for NO. If answered "Y", you will see next question.
WAIT ....
Wait for further instructions.
REMOVE ALL WEIGHT
THEN PRESS ENTER
For Applications: Place test weight(s) on scale.
APPLY WEIGHT
THEN PRESS ENTER
GROSS WEIGHT
SCALE X = XXXX
Your scale is now calibrated and goes into the gross weight display mode.
All Chlor-Scales, Chem-Scales and Drumm-Scales are factory calibrated for your specific
application. Should you notice any error, field calibration can be performed as follows:
WAIT....
Wait for further instructions.
ENTER VALUE
XXXX
For Applications: Key in the combined gross weights (net
WEIGHT contents and tare weights) using the key pad then press enter.
For Applications: Key in the test weight(s) using the key pad,
then press enter.
CL2 & SO2
ALL OTHER
To set your "ZERO", remove all weight from the scale.
For Applications: Place full container(s) on scale.
For Applications. Consult Factory
ALL OTHER
CL2 & SO2
CHEM and DRUM SCALES
9081 FIELD CALIBRATION
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZSETUP6.tcw (B19.pdf)
QUESTIONS ? Help Hotline: 1-800-893-6723
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
W.3.101
Loosen backstop bolts
and slide backstop
toward edge of platform.
IMPORTANT !
To insure accurate weight readings, it is critical
that the load is properly centered
within the "CALIBRATION RING".
1) Loosen the backstop hold-down
nuts and slide the backstop toward
the edge of the platform.
2) Place the container that is to be
weighed (or an empty container that
is the same diameter of the container
to be weighed) on the platform.
Using the CALIBRATION RINGS
on the platform as the "target",
center the container within the
calibration rings.
3) Slide the backstop against the
container and tighten the backstop
hold-down bolts.
When using containers with the same diameter there is no need to readjust the backstop. Simply slide the
new container against the backstop making sure the container is centered in the Calibration Rings.
STEP 2:
Place container on Platform
and CENTER it on the
Calibration Rings.
STEP 3:
Slide backstop
against container
and tighten bolts.
Backstop
Bolts (2)
Container CENTERED in Calibrating Rings
Container OFF CENTER of Calibrating Rings
CALIBRATING THE SCALE
CORRECT
INCORRECT
FOR SCALES WITH SLOTTED PLATFORM(S) ONLY !
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
WWW.FORCEFLOW.COM / [email protected]
REF: T4\O&M\CYLHYD\200SLOT4.tcw (L09.pdf)
C.3.105
X.3.105
S.3.105
W.3.105
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
QUESTIONS ? Help Hotline: 1-800-893-6723
W.3.301
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
File: T4\O&M\AWZMSTR\WZTRBSHT.tcw (B20.pdf)
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
- Exit CODE SET-UP function, then push "arrow" key.
Cannot get INTO the MENU:
PROBLEM
SOLUTION
Cannot get OUT OF the MENU:
Cannot get OUT OF the CODE SET-UP:
AMOUNT USED and DAILY
USAGE values are incorrect.:
NET REMAINING is NOTcorrect:
FEED RATE and DAYS UNTIL
EMPTY is incorrect:
ALARM does NOT operate:
Alarm RESET does NOT operate:
PRINTER does NOT operate:
4-20mA SIGNAL does NOT operate:
READOUT does NOT operate:
Fluctuating readings or
inacurate readings.
- Push DELETE
- Keep pushing ENTER until you get to the display.
- When in the TANK LOAD mode, make sure you wait until the:
"CHANGE TANKS NOW" (for PORTABLE tank applications)
or "FILL TANKS NOW" (for PERMANENT tank applications)
before loading/unloading of tanks/chemicals.
- If using AUTO TARE mode, make sure you are using full tank(s).
- If you are using MANUAL TARE mode, make sure you are entering
the correct tare weight(s) for your tank(s).
- If you don't replace all tanks on a multiple tank scale, you must
use MANUAL mode.
- If all else fails, recalibrate under CODE SET-UP 9081 under field calibration.
- Read CODE SET-UP 9082 under custom formatting thoroughly and adjust accordingly.
- Make sure you purchased this option.
- Make sure alarm for that scale is ENABLED under CODE SET-UP 4200.
- Make sure relay is wired NORMALLY OPEN under indicator wiring instructions.
- You must first correct your alarm condition before attempting to reset
(i.e. fill your tank, or load a full tank beforehand).
- Make sure printer protocol has been set properly (see #4 PRINTER COMMUNICATIONS
in Indicator Installation & Wiring)
- Printer must have at least 24 character width capability and a 2K buffer.
- Make sure you purchased this option.
- Make sure there is no more than 975 Ohms load on 4-20mA loop.
- Make sure 4-20mA signal is formatted properly under CODE SET-UP 3256.
- Check for proper power connections.
- Check fues in Indicator.
- Make sure load cell cable is not in proximity to any other power wiring.
TROUBLESHOOTING
REF: T4\O&M\CARBHYD\PARTCARB.tcw (L10.pdf)
Carboy Platform:
200# Capacity
400# Capacity
600# Capacity
HYDRAULIC: MA-150 Transmitter (24 Volt)
Power Supply
XT: Loop Powered 4-20mA Output (Optional)
ELECTRONIC: Consult Factory
CENTURY: 4-1/2" dia.meter Dial
SOLO 1000
WIZARD 4000-1 or -2
WIZARD 4000-3 or -4
SOLO XT (Battery or Loop Powered)
HYDRAULIC only: RS-150 Reed Switch with
Reset Relay Box
ELECTRONIC WIZARD: W5ASP Alarm Switch
ELECTRONIC SOLO: S5ASP Alarm Switch
HYDRAULIC or XT:
PS-10 Fixed Pressure Switch
REED
SWITCH
RELAY
BOX
PRESSURE SWITCH
5a: ELECTRONIC: Electronic Cable only
5b HYDRAULIC or XT: PVC Copper Tubing only
4b
4
5b
6
7
8
9
7
6
9
8
2
5
1
3
4a: Internal 1.25 Load Cell Diaphragm
4b: Pint of RO-5 Oil
OIL
1
Load Cell (#3b) with PVC Copper
Tubing (#5b)
3b
30174
PARTS LIST
for CARBOY SCALE
200# to 600# Capacities
TRANSMITTER
1150-D Burnett Ave, Concord, CA 94520 USA
1-800-893-6723 US & Canada, Fax: 925-686-6713
www.forceflow.com / [email protected]
Drawn by: SLP
Date: 01/05/89
Revised: 08/15/00
Scale: NONE
Drawing Number
FORCE FLOW
FORCE FLOW
F
F L
L O
O Q
Q
U II
U
P
P
723.4
SOLO 1000
Indicator
WIZARD 4000
0
9
1
2 3
4 5
6 7
8
SCALE 1 150 LBS
SCALE 2 300 LBS
WIZARD 4000
Indicator
CENTURY
Hydraulic Dial Indicator
Electronic
COMPRESSION
LOAD CELL
Hydraulic
LOAD CELL
5a
3a
HYDRAULIC:
or XT
ELECTRONIC: Load Cell (#3a) with
Cable (#5a) (consult factory)
HYDRAULIC or XT SCALES ONLY:
6
6
9
9
7
7
ACCESSORIES
CONSULT FACTORY FOR CURRENT PRICING
1-800-893-6723 Fax: 925-686-6713
PARTS LIST
SCALE PLATFORM
Platform Backstop
2
C.3.401
C.3.401
X.3.401
X.3.401
W.3.401
W.3.401
S.3.401
S.3.401
SOLO XT
CROSS TECHNOLOGY
150
150
6
SOLO XT
Cross Technology
Indicator
9
PRESSURE SWITCH
8