A zone that will not generate an alarm during the entry delay.

-D- Dealer Lockout An option that disables the default restore code “123456”. Default Program The default program contains the factory parameter settings. For typical installations, the default program minimizes the amount of programming that needs to be performed by the installer. Detailed Display The keypads for each sub-system can be programmed to show a detailed or summarized display of the system. The detailed display includes system troubles, sub-system status, time ...

ADDRESSES 497-498: AC LOSS & RESTORE

497 AC loss report delay. The AC loss report delay determines how many minutes the panel will wait after AC power has been lost before transmitting a message to the central station. Select a value in hexadecimal for the AC loss report delay. For hexadecimal value conversions refer to the hexadecimal conversion chart located in Appendix B. 498 AC restore report delay. The AC restore report delay determines how many minutes the panel will wait after AC power has been regained before transmitting a message to the central station. Select a value in hexadecim ...

A keypad display mode without zone status – see Detailed Display.

Supervised Keypad A supervised keypad generates an alarm when disconnected from the control panel. Swinger Zone A zone from which the number of alarms sent within a predetermined time period is limited. -T- Telephone Com- municator Test A manual test that checks the control panel’s ability to communicate with all programmed telephone numbers. Toll Saver See Callback. Transistor Module Peripheral add-on module that uses transistors instead of relays to provide programmable outputs – See Output Relay. T ...

ADDRESSES 000-127: ZONE PARAMETERS

000-003: Zone # 1 Parameters Each zone is individually defined in four parameter addresses. The following four addresses relate to zone 1 but the method of programming zones 2 - 32 is identical. 000 LCD Zone Descriptor and Entry Delay for Zone #1 Select a zone descriptor and entry delay for zone 1 from the table below. Entry delay options #1, #2 and #3 are set at addresses 382, 383 and 384, respectively. The four custom LCD messages can be programmed at addresses 412-475. No Delay Delay #1 Delay #2 Delay #3 Descriptor No Delay Delay #1 Delay #2 Delay #3 D ...

ADDRESSES 412-475: CUSTOM LCD ZONE DESCRIPTORS

Four of the descriptors that can be assigned to each zone (see Address 000) can be customized to suit a specific installation. A total of sixteen characters, including spaces, can be entered for each LCD custom zone descriptor using the following table. Each custom zone descriptor is entered in a series of consecutive addresses. It is recommended to fill in all 16 characters for each custom zone descriptor. Example: To set Custom Zone Descriptor 1 as “ABC”, enter 41, 42, 43, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20 at addresses 41 ...

3.9: Event Log

The event log records the last 100 events the system has undergone. The event log uses the FIFO (first in, first out) method. Once the log is full, the oldest event will automatically be erased. The event log can only be viewed with the LCD keypad. View Event Log To view the event log: 1. From the View/Log menu select View Log or press SELECT 6, 1. 2. Enter an authorized user code. 3. Scroll through the log by pressing the MENU/NEXT key. The events are displayed starting with the most recent event registered in the log. 4. Press AWAY to exit the log. The following table shows ...

Menu Selections Using the LCD Keypad

To make a menu selection from the menu: 1. Press MENU/NEXT; the main menu will be displayed and the selection pointed to by >. 2. Press MENU/NEXT to scroll through the menu items. Pressing “,“scrolls backwards and pressing any numeric key displays that number’s associated menu item. To abort at any time, press AWAY. 3. Press SELECT to select the displayed menu item (indicated by the arrow). Certain menu items may require an authorized passcode. Example: Selection Display Pressing MENU/NEXT for the first time displays > 1 O P E N / D I S A R M ...

Electronics Line 3208GLD user guide recommended for: infinite prime, iconnect, Penta, SecuPlace, Prime.

⚠️ Download Safety

The Control Panel Installation, operation, and programming manual (51 pages) is completely safe to download (last scan date: 27/01/2026).