IBM 3708 Planning And Installation

Text of the manual

Fourth Edition (February 1988)

This edition obsoletes GA27-3766-2. Changes are made periodically to the information herein; before using this publication in connection with the operation of IBM systems or equipment, consult the latest IBM System/370, 30xx and 4300 Processors Bibliography, GC20-0001; System/38 Bibliography, GH30-0233; and 8100 Bibliography, GC20-8100, for the editions that are applicable and current. Any reference to an IBM licensed program in this document is not intended to state or imply that only IBM's licensed program may be used. Any functionally equivalent program may be used instead. It is possible that this material may contain reference to, or information about, IBM products (machines and programs), programming, or services that are not announced in your country. Such references or information .must not be construed to mean that IBM intends to announce such IBM products, programming, or services in your country. Publications are not stocked at the address given below; requests for IBM publications should be made to your IBM representative or to the IBM branch office serving your locality. A form for reader's comments is provided at the back. of this publication. If the form has been removed,. comments may be addressed to IBM Corporation, Communication Products Information Development; Department E02, P.O. Box 12195, Research Triangle Park, North Carolina, U.S.A. 27709. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation wha~ver .. You may, of course, continue to use the information you supply. ©Copyright 1986,1987,1988

Federal Communications Commission (FCC) Statement

Warning: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. Instructions to User: In many instances, shielded cables and connectors must be used for connection to peripherals. Proper IBM cables are available from authorized dealers. The manufacturer is not responsible for any radio or television interference caused by using other than the recommended cables or by unauthorized modifications to this equipment; it is the responsibility of the user to correct such interference. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: How to Identify and Resolve Radio-TV Interference Problems This booklet is available from the following: FOB Public Contact Branch Room 725 1919 M St. NW Washington, DC 20554 Tele. (202) 634-1940 Consumer Assistance and Small Business Division Room 254 1919 M St. NW Washington, DC 20554 Tele. (202) 632-7000 The information in this document is current as of the date of its publication but is subject to change by IBM at any time without notice. The cable information contained in this document is not intended to be a specification for cable structures and/or cable connectors and all liability for patent infringements due to manufacture use or sale of cables and/or connectors in accordance with this document is expressly disclaimed by IBM. No license express or implied is intended or granted under any patents of IBM or others to make, use, sell, or combine these structures and/or connector structures alone or in combination with any other devices. Proper operation of the cable as well as quality ormanufacture are the responsibility of the user and the selected supplier. This manual contains several trademarks and registered trademarks. Viewpoint is a registered trademark of Applied Digital Data Systems, Inc. Beehive is a trademark of Beehive International. Dasher is a registered trademark of the Data General Corporation. DEC is a registered trademark of the Digital Equipment Corporation. ESPRIT I and ESPRIT II are trademarks of Esprit Systems, Inc. FALCO 500 is a registered trademark of Falco Data Products, Inc. Dumb Terminal is a registered trademark of Lear Siegler, Inc. Displayphone is a trademark of Northern Telecom, Inc. TeleVideo is a registered trademark ofTeleVideo Systems, Inc. WY-50 is a registered trademark ofWyse Technology. iii

About This Book

This book contains planning and installation information about the IBM 3708 Network Conversion Unit. This information is for people who plan for and install the 3708. To use the information, you should be familiar with the following: • American National Standard Code for Information Interchange (ASCII) • Asynchronous (start-stop) devices • IBM 3270 Information Display System • Systems Network Architecture (SNA). It is recommended that you read the information in the planning chapters before installing the 3708. If the configuration planning and site preparation are complete, begin with the procedures in "Installing the 3708." How This Book Is Organized This book is divided into three parts: "Introducing the 3708" contains the following chapters: • Chapter 1, "The 3708 and Its Advantages" provides general information about the 3708. • Chapter 2, "Operating Mode Functions" describes the functions that the 3708 provides in protocol conversion, protocol enveloping, and ASCII pass-through modes. • Chapter 3, "Host and ASCII Device Interfaces" describes the connections between the 3708 and the hosts, and between the 3708 and the ASCII end-user devices; "Planning for the 3708" contains the following chapters: • Chapter 4, "Planning Checklist" provides a planning checklist and planning forms. • Chapter 5, "Planning for Installation" describes the physical requirements for installing the 3708. • Chapter 6, "Planning for Service" provides service and warranty information for the 3708. • Chapter 7, "Planning for Microcode Updates" describes the 3708 microcode update procedure. • Chapter 8, "Planning for Central Site Configuration" provides planning information for IBM 3708 Network Conversion Unit Feature 3525 (pluggable Cartridge with Central Site Configuration). About This Book V

• Chapter 9; "Planning for File Transfer" describes supported file transfer

programs. • Chapter 10, "Planning for Cables" provides information to help you plan for the cables and the cable connections for the 3708. • Chapter 11, "Ordering the 3708" describes items that can be ordered for the 3708. "Installing the 3708" contains the following chapters: • Chapter 12, "Installation Procedures" explains how to configure the 3708 ports for SNA and ASCII hosts and for end-user devices. • Chapter 13, "Configuration Procedures" describes the screen sequences that are used for configuring the 3708. • Chapter 14, "Defining the General Definition" describes the "General Definition" screen. • Chapter 15, "User-Defined Terminal Tables" describes user-defined terminal tables and explains how to create new ones. • Chapter 16, "Converting Between Standard and Enhanced UDTs" explains how to convert standard terminal tables to enhanced, and vice versa. • Chapter 17, "Creating a User-Defined Translate Table" describes user-defined translate tables and explains how to create new ones. This manual also contains 14 appendixes: • Appendix A, "IBM-Supplied Configuration" • Appendix B, "3708 Configuration Example" • Appendix C, "3708 Configuration Forms" • Appendix 0, "Cable Requirements" • Appendix E, "Screen Sequences" • Appendix F, "3708 Control Terminal Messages" • Appendix G, "Default Terminal Tables" • Appendix H, "Predefined User-Defined Terminal Tables and Keyboard Mappings" • Appendix I, "Terminal Switch Settings" • Appendix J, "Terminal XON/XOFF Pacing Support" • Appendix K, "Manuals for Default Protocol Conversion Displays" • Appendix L, "IBM-Supplied Translate Tables" • Appendix M, "End-User-Device Reference Cards Order Form" • Appendix N, "Binary to Hexadecimal Conversion Table." vi 3708 Planning and Installation

Related 3708 Library Publications

The following lists manuals and information for the 3708: • IBM 3708 Network Conversion Unit Setup, GA27-3611, is shipped with the 3708 and describes how to set up and test the 3708, how to handle setup problems, and how to prepare the 3708 for relocation. • IBM 3708 Network Conversion Unit Description, GA27-3768, describes the external interfaces and operational characteristics of the 3708. • IBM 3708 Network Conversion Unit Problem Determination, GA27-3767, provides procedures for solving 3708 problems. • Unpacking instructions are printed on the 3708 shipping carton and show how to unpack the 3708. • IBM 3708 Network Conversion Unit Problem Report, GA27-3638, which is shipped with the 3708, provides a means of recording problem diagnosis information that is used by repair center representatives. • IBM 3708 Network Conversion Unit End-User Reference, GA27-3765, describes the procedures for operating terminals attached to the 3708. • IBM 3708 Network Conversion Unit Registration Address Form is shipped with the 3708. This form must be completed and returned to IBM for you to automatically receive notification of changes in the 3708 microcode. • IBM 3708 reference cards describe the keyboard functions of ASCII displays that can be connected to a 3708 and describe the general procedures for terminal users. See Appendix M, "End-User-Device Reference Cards Order Form," for a list of the end-user devices and the 3708 reference card order numbers. Service Information For service on 3708 hardware and microcode problems, call the following number in the United States or Puerto Rico: 1 800 428-2569 (toll free) In other countries, call the appropriate support group. About This Book vii

Changes Since the Last Edition

This edition contains the following new information: • Descriptions of enhanced terminal support IBM 3270 Model 2, 3, 4, and 5 emulation - Customized UDT names - Customized Terminal Logon Initialization Sequence. • Default terminal tables and switch settings for the following terminals: IBM 3151 - FALCO-500® - WY-50®. • A description of a new host port inactivity time out option • A description of a new printer capability option, "Perform Newline at Begin Bracket (LU_3)" • Descriptions of additional support in the non-standard operations field. Changes Since the Last Edition ix

Introducing the 3708

Chapter 1. The 3708 and Its Advantages ...................... . Overview ........................................ . Physical Description .................................. . Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Network Configurations ............................. . Control Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . Summary of Advantages ........ ....... . . . . . . . . . . . . . Chapter 2. Operating Mode Functions . . . . . . . . . . . . . . . . . . Protocol Conversion .......................... . Protocol Enveloping .......................... . ASCn Pass-Through ................................. . Function Summary .......................... . Chapter 3. Host and ASCn Device Interfaces . . . . . . . . . . . . SNA Hosts ............................... . ASCn Hosts .............................. . Ascn End-User Devices 1-1 1-1 1-1 1-2 1-2 1-4 1-5 2-1 2-1 2-4 2-4 2-5 3-1 3-1 3-2 3-2 Planning for the 3708 Chapter 4. Planning Checklist ...................... . Planning Configuration Parameters . . . . . . . . . . . . . . . . . Device Information Form ........................ . Network Planning Form ....................... . Port Definition Form ......................... . Chapter 5. Planning for Installation Specifications and Location Requirements Interface Requirements ......... . Power Requirements ........... . Safety and Security Consid,erations .. . Chapter 6. Planning for Service ..................... . Reviewing the Service and Warranty Options ............. . Calling for Service ............................. . 4-1 4-2 4-3 4-4 4-5 5-1 5-1 5-2 5-2 5-5 6-1 6-1 6-3 Chapter 7. Planning for Microcode Updates ..................... 7-1 How to Register ..................................... 7-1 What to Expect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 7-1 How to Order ...................................... 7-1 What to Do with Outdated Cartridges ........................ 7-2 Chapter 8. Planning for Central Site Configuration ................ 8-1 IBM 3708 Pluggable Cartridge with Central Site Configuration ......... 8-1 Hardware Requirements ................................ 8-2 Software Requirements ................................. 8-2 Contents xi

Installing the 3708

Software Options that Enhance CSC 3708 Configuration Requirements .. Modem Configuration Requirements Technical Assistance ..... . Ordering Information ........ . 8-3 8-4 8-5 8-5 8-5 Chapter 9. Planning for File Transfer ................... 9-1 IBM PC/HOST File Transfer and Terminal Emulator Program ......... 9-1 Personal Services/PC ....................... 9-3 A User-Written File Transfer Program ........................ 9-3 Chapter 10. Planning for Cables .......... . · . . . . . . . . . .. 10-1 Cable Descriptions ...................... . · . . . . . . . . . .. 10-1 Examples of 3708 Cable Connections ....... . · ........... 10-2 3708 Connection to the IBM Cabling System .. . 3708 Problems Related to Cables or Equipment · . . . . . . . . .. 10-11 . . . . . . . . . . .. 10-12 Chapter 11. Ordering the 3708 Order Forms .......... . 11-1 11-1 Chapter 12. InstaUation Procedures ............... 12-1 Step 1. Testing the 3708 ..................... 12-2 Step 2. Setting Up the Control Terminal . . . . . . . . . 12-4 Step 3. Logging onto the Control Terminal ......... . . . . .. 12-5 Step 4. Entering the Configuration Data ........... . . . . .. 12-9 Step 5. Activating the Configuration ......................... 12-9 Step 6. Ending the Control Terminal Session . . . . . . . . . . . . . . . . . .. 12-10 Step 7. Connecting the Cables . . . . . . . . . . . . . . . . . . . . . . .. 12-13 Chapter 13. Configuration Procedures ........................ 13-1 Defining a Port for a SNA Host ........................... 13-2 Defining a Port for an ASCII Host ..................... 13-10 Defining a Port for an End-User Device ...................... 13-15 What To Do Next ................................... 13-35 Protocol Enveloping Definition for an End-User Device (Screen CI23.4) 13-36 Defining the Printer Authorization Matrix ............... 13-41 Chapter 14. Defining the General Definition General Definition (Screen CI27.1) .... Chapter 15. User-Defined Terminal Tables Standard and Enhanced Terminal Tables Creating a User-Defined Terminal Table Looking at the Terminal Table Format Chapter 16. Converting Between Standard and Enhanced UDTs '" Converting Standard to Enhanced . . . . . . . . . . . . . . . . . . . Converting Enhanced to Standard .............. . Chapter 17. Creating a User-Defined Translate Table ... . Looking at the Translate Table Format ................ . Defining a New Translate Table ..................... . 14-1 14-1 15-1 15-1 15-2 15-3 16-1 16-3 16-3 17-1 17-1 17-2 xii 3708 Planning and Installation

Appendix A. IBM-Snpplied Configuration ...................... A-I

PORTS 1 through 5 ................................... A-I PORTS 6 through 9 ................................... A-3 PORT 10 ......................................... A-4 Appendix B. 3708 Configuration Example ...................... B-1 Ports Configured for Hosts ............................... B-3 Ports Configured for Terminals Only ......................... B-5 Ports Configured for Multiple LUs .......................... B-9 Ports Configured for Printers Only ......................... B-13 Appendix C. 3708 Configuration Forms ....................... C-l End-User Device Definitions .............................. C-2 Host Definitions ..................................... C-4 Appendix D. Cable Requirements ........................... D-l Section 1. 3708 EIA 232C Interface Cables from IBM .............. D-l Section 2. Minimum Connections Required for IBM 3708 EIA 232C Cable D-6 Section 3. IBM 3708 EIA 422A Interface Cables ................ D-I0 Section 4. IBM 3708 EIA 422A Interface to IBM Cabling System ...... D-13 Appendix E. Screen Sequences ............................ E-l SNA Hosts ........................................ E-l ASCII Hosts ....................................... E-2 Printers .......................................... E-3 Displays, Protocol Conversion Only ......................... E-4 Displays, Protocol Enveloping Only or Dynamic .................. E-5 Displays with Printers, Protocol Conversion Only ................. E-6 Display with Printer, Dynamic ............................ E-7 Appendix F. 3708 Control Terminal Messages ................... F-l Unnumbered Messages ................................. F-l Numbered Messages ................................... F-3 Appendix G. Default Terminal Tables ........................ G-i ADDS (Applied Digital Data Systems) Viewpoint® ................ G-1 Beehive™ ATL-078 ................................... G-6 Data General Dasher® D210 Display Terminal ................. G-l1 DEC® Model VT52 .................................. G-16 DEC® Models VT100 (or VT220 Emulating a VT100) ............. G-21 DEC® Model VT220 ................................. G-26 FALCO 500® (Emulating a DEC® Model VT220) ............... G-31 Hazeltine Esprit ITM and Esprit IITM ........................ G-36 Hazeltine 1500 ..................................... G-4l Hewlett-Packard 2621B Interactive Terminal ................... G-46 IBM PC/FTTERM Color .............................. G-51 IBM PCfFTTERM Monochrome .......................... G-56 IBM 3101 and IBM PC in 3101 Emulation Mode ................ G-61 IBM 3151/62 (Model 5 Emulation) ......................... G-66 IBM 3151, 3161, 3162, and 3163 ASCII Display Stations ,........... G-71 IBM 3151/61/62/63 with 3708 Feature ....................... G-76 IBM 3164 ASCII Display Station .......................... G-81 IBM 3164 with 3708 Feature ............................. G-86 COntents xiii

Lear Siegler ADM 3A Dumb Terminal® .................... .

Northern Telecom Displayphone™ ........................ . ROLM Cypress, Cedar, and Juniper ....................... . Teletype 5410 Asynchronous Display Terminal and 5420 Buffered Display TeleVideo® 910 ................................... . TeleVideo® 950 ................................... . WY-50® ........................................ . G-91 G-96 G-lOl G-106 G-ll1 G-116 G-121 Appendix H. Predefined User-Defined Terminal Tables and Keyboard Mappings H-l ADDS (Applied Digital Data Systems) Viewpoint®/18 .............. H-l Lear Siegler ADM 24E Video Display Terminal .................. H-7 Lear Siegler ADM 31 Intermediate Terminal™ Video Display Unit H-12 TeleVideo® 912C ................................... H-17 Appendix I. Terminal Switch Settings ........................ . ADDS Viewpoint® ................................... . ADDS Viewpoint®/78 ................................. . Beehive™ ATL-078 ................................... . Data General® D210 Display Terminal ....................... . DEC® VT100 and VT52 ................................ . DEC® VT220 (Emulating a VT100) ......................... . DEC®VT220 ...................................... . FALCO 500® ...................................... . Hazeltine ESPRIT ITM ................................ . Hazeltine ESPRIT IJTM ................................ . Hazeltine 1500 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 1-10 1-11 1-12 Hewlett-Packard 2621B Interactive Terminal .................... 1-13 IBM PC/FTTERM (Color and Monochrome) ................... 1-14 IBM PC in 3101 Emulation Mode .......................... 1-15 IBM 3101 Models 10, 12, 13, 20, 22, 23 ....................... 1-16 IBM 3151 ASCII Display Station ........................... 1-17 IBM 3161 ASCII Display Station ............................ 1-19 IBM 3162 ASCII Display Station ........................... 1-21 IBM 3163 ASCII Display Station ........................... 1-23 IBM 3164 ASCII Display Station ........................... 1-25 Lear Siegler ADM 24E Video Display Terminal .................. 1-27 Lear Siegler ADM 3A Dumb Terminal® ...................... 1-29 Lear Siegler ADM 31 Intermediate Terminal™ Video Display Unit ...... 1-30 Northern Telecom Displayphone™ .......................... 1-31 ROLM® Cypress™, Cedar™, and JuniperTM .................... 1-32 Teletype 5410 Asynchronous Display Terminal ................... 1-33 Teletype 5420 Buffered Display ............................ 1-34 TeleVideo® 910 ..................................... 1-36 TeleVideo® 912C .................................... 1-37 TeleVideo® 950 ..................................... 1-38 WY-50® .......................................... 1-39 Appendix J. Terminal XONjXOFF Pacing Support ............... . J-l Appendix K. Manuals for Default Protocol Conversion Displays ......... K-1 Appendix L. mM-Supplied Translate Tables .................... L-l Standard Default EBCDIC to ASCII Translate Table ............... L-2 Standard Default ASCII to EBCDIC Translate Table ............... L-8 Appendix M. End-User-Device Reference Cards Order Form ........... M-1 xiv 3708 Planning and Iqstallation

Appendix N. Binary to Hexadecimal Conversion Table .............. N-I

list of Abbreviations ................................... X-I Glossary ...... . Index ........ . x-s X-I3 Contents XV

3708 Network Conversion Unit

Two Kinds of SNA Host Connections SNA and ASCII Host Connections Network Planning Form .......................... . Network Planning Form Example .................... . Port Definition Form ........................... . Port Definition Form Example ...................... . Power Plugs by Country .......................... . Power Plugs and Receptacles ....................... . 3708 M120 screen .............................. . UDT Conversion Screen (MI28.0) .................... . Sample 3708 Configuration ........................ . SNA Hosts .................................. . ASCII Hosts ................................. . Printers .................................... . Displays, Protocol Conversion Only ................... . Displays, Protocol Enveloping Only, or Dynamic ........... . Displays with Printer, Protocol Conversion Only ........... . Display with Printer, Dynamic ...................... . 1-2 1-3 1-4 4-4 4-5 4-6 4-7 5-3 5-4 16-1 16-2 B-2 E-l E-2 E-3 E-4 E-5 E-6 E-7 Figures xvii

This part contains the following chapters:

Chapter 1. The 3708 and Its Advantages Overview ..... . Physical Description Operating Modes .. Network Configurations Control Terminal Summary of Advantages Chapter 2. Operating Mode Functions Protocol Conversion Display Support Printer and Keyboard Printer Support Multiple Logical Unit Support Protocol Enveloping ASCII Pass-Through Function Summary Chapter 3. Host and ASCII Device Interfaces SNA Hosts ....... . ASCII Hosts ...... . ASCII End-User Devices Protocol Conversion Mode Default Mappings . User-Defined Keyboard Mappings Printers and Keyboard Printers Protocol Enveloping Mode ASCII Pass-Through Mode .. Introducing the 3708 1-1 1-1 1-1 1-2 1-2 1-4 1-5 2-1 2-1 2-1 2-3 2-3 2-4 2-4 2-5 3-1 3-1 3-2 3-2 3-2 3-3 3-4 3-4 3-5 3-5 Introducing the 3708

Chapter 1. The 3708 and Its Advantages

Overview This chapter provides the following general information about the 3708: • Overview • Physical description • Operating modes • Network configurations • Monitoring and controlling the 3708 • Summary of advantages. The 3708 provides a physical and logical interface for connecting ASCII end-user devices! to an SNA network. It has 10 communication ports that can be defined for various network configurations and operating modes. The network can contain ASCII hosts, which include personal computers, as well as SNA hosts. Physical Description The 3708, which is shown in Figure I-Ion page 1-2, is small, lightweight, and portable. It consists of two modular, customer-replaceable hardware components: a base and a cartridge. The back panel of the base contains 10 numbered ports for connecting hosts and ASCII end-user devices. The 3708 measures 400 mm by 355 mm by 105 mm (15.8 in. by 14.0 in. by 4.1 in.), weighs approximately 5.6 kg (12.3Ib), and can be placed on a shelf in a standard 19-inch rack. 1 ASCII end-user devices use asynchronous start~stop data transmission and include displays, printers, keyboard printers, keyboard displays with attached printers, plotters, personal computers, and devices that use ANSI X3.64. Chapter 1. The 3708 and Its Advantages 1-1

Figure 1-1. 3708 Network Conversion Unit

Operating Modes Cartridge Light '-----Base Power On/Off Light Not Ready Light The 3708 provides three modes of operation, which it can perform simultaneously, for different network configurations: • 3270 applications running on an SNA host. The 3708 provides protocol conversion mode for communication between an ASCII end-user device and 3270 applications running on an SNA host. This mode changes a start-stop data stream from an ASCII device into a 3270 data stream and provides 3274 Control Unit functions, including 3270 full-screen support. • Line-by-line applications running on an SNA host. The 3708 provides protocol enveloping mode for communication between an ASCII end-user device and line oriented applications running on an SNA host. In this mode, the 3708 surrounds the data stream from an ASCII device with SNA headers. Devices that normally communicate with host applications through the start-stop support of the Network Terminal Option (NTO) can communicate through the 3708. NTO start-stop support is not required for 3708 operations and can be eliminated from the communication controller. • Applications running on an ASCII host. The 3708 provides ASCII pass-through mode for communication between an ASCII display and applications running on an ASCII host. This mode passes a start-stop data stream between an ASCII display and an ASCII host without changing the data stream in any way. Network Configurations The 3708 provides 10 communication ports that can be defined for various configurations of SNA hosts, ASCII hosts, and AscII end-user devices. The host may be directly attached or may be remotely attached over nonswitched (leased) lines. ASCII devices may be directly attached or may be. remotely attached over switched or nonswitched lines. Line speeds of up to 19200 bps can be used. 1-2 3708 Planning and Installation

As many as two ports can be defined for SNA hosts. Each of these ports can

connect to separate hosts, or both can connect to the same host. SNA Host* 3708 ASCII Devices ASCII Devices Figure 1-2. Two Kinds of SNA Host Connections * For a list of SNA hosts that the 3708 supports, refer to "SNA Hosts" on page 3-1. As many as nine ports can be defined for ASCII hosts. Each of these ports can connect to separate hosts, or multiple ports can connect to the same host, depending on the host. Figure 1-3 on page 1-4 shows a configuration with one SNA host and one ASCII host. Chapter 1. The 3708 and Its Advantages 1-3

Figure 1-3. SNA and ASCII Host Connections

* For a list of SNA hosts that the 3708 supports, refer to "SNA Hosts" on page 3-1. When a 3708 port is connected to an SNA host, multiple end-user devices can communicate at the same time over that one line. When a 3708 port is connected to an ASCII host, only one end-user device at a time can communicate over that line. However, multiple devices can communicate at the same time with an ASCII host if each device has a separate line to the host. Control Terminal A control terminal can be used for monitoring and controlling the 3708. Any display that operates in protocol conversion mode can be the control terminal if it is logged on to the 3708 in control terminal mode. The 3708 allows only one display at a time to be logged on in control terminal mode. The control terminal can be either directly or remotely connected to the 3708. The control terminal is also used to define the configuration of the 3708. An IBM-supplied configuration allows many types of displays to be used as a control terminal for defining the initial configuration of the 3708. The 3708 provides default keyboard mappings for these terminals. (Refer to "ASCII End-User Devices" on page 3-2 for a list of the default terminals.) You must have one of these terminals to define the initial configuration for the 3708. After initial configuration, other types of displays can be defined for use as a control terminal. "Step 3. Logging onto the Control Terminal" on page 12-5 contains step-by-step procedures for logging on to the control terminal. 1-4 3708 Planning and Installation

The control terminal operator can perform the following functions:

• Define or change: Host ports and host access Device ports Control terminal access Control terminal password Port passwords Translate table Keyboard mappings Printer access World Trade language to be used for 3708 logon Suppression of 3708 logon screens. • Display information, such as: Configuration data Response time statistics Alert log and other error information. • Monitor the 3708 by checking: - Port status - Data transmitted on lines connected to the 3708. Note: If a printer is connected to the 3708, the control terminal screens showing configuration information can be printed as a local copy operation. Summary of Advantages The 3708 provides the following advantages: • It reduces communication costs by reducing the number of telecommunications lines needed, by reducing the number of communication controller ports needed, and by allowing a display with a connected printer to share a single communication downstream line. • It supports personal computer file transfer through the IBM PC/HOST File Transfer and Terminal Emulator Program (FTTERM). • It allows you to manage the configuration and microcode fixes of the 3708s in a network from a central control point. This management capability is provided by 3708 Feature 3525 (pluggable Cartridge with Central Site Configuration) and its associated PC aid. • It supports network management by sending alert messages to NetView or to the Network Problem Determination Application (NPDA) and response time statistics to NetView or to the Network Logical Data Manager (NLDM) for displays that are connected for protocol conversion, and by notifying an SNA host of changes in the power status of attached ASCII end-user devices. • It supports multiple modes of operation. Protocol conversion, protocol enveloping, and ASCII pass-through modes can be supported simultaneously. • It eliminates the need for NTO start-stop support in the communication controller by providing protocol enveloping for ASCII end-user devices that are compatible with TWX 33/35. Chapter 1. The 3708 and Its Advantages 1-5

• It cQnnects to most ASCII displays using standard 128.:.character ASCII in

protocol conversion mode. The 3708 provides ASCII~to-3270 keyboard mappings for many displays and allows additional keyboard mappings to be defined at the control tenriinal. • It supports IBM 3270 Models 2,3,4, and 5 emulation when operating in protocol conversion mode. • It allows the sharing of printers. The printer can be defined to allow output from the host, local screen copies from one or more ASCII displays operating in protocol conversion mode, or both host output and local screen copies. It also supports printers that are connected to displays (MLU). • It reduces terminal costs by allowing inexpensive ASCII end-user devices to be used in an SNA network. • It provides flexibility by allowing a single ASCII device to be connected to either an SNAhost or an ASCII host (which may be a personal computer) and by allowing access to ASCII and 3270 applications at an SNA host. • It helps in migrating to SNA by allowing end users to access 3270 application programs through ASCII devices. • It provides security for data and applications by allowing an optional password for each port, by allowing host and printer access to be defined, and by ending a session whenever it detects an abnormal disconnection. • It provides an optional inactivity time-out that may be used to disconnect terminals, thus reducing security exposures and limiting dial charges on switched lines. • It connects to devices that use special characters or nonstandard codes by providing ASCII-to-EBCDIC translate tables. An additional translate table can be defined using the control terminal. • It allows the SN A host to dial out to devices in protocol enveloping mode. • It alliJws a display to dial out to an ASCII host in ASCII pass-through mode. • It supports transparent operations in protocol enveloping. Ports can be defined to allow transparent data flow to and from the host. This feature provides support for devices such as graphics displays, printers, and plotters. • It allows an operator to define the 3708 configuration and to monitor and control the 3708 by using an ASCII display as a control terminal. A password protects access to control terminal functions. When not used as a control terminal, the ASCII display is available as an end-user device. • It allows a port to be defined to allow protocol conversion, protocol enveloping, or both depending on the type of session requested by a host All ports can be defined to allow ASCII pass~through. • It allows a port to be defmed to automatically determine the parity and line speed (from 110 to 4800 bps and 9600 bps) for both switched and nonswitched lines. • It attaches to the IBM cabling system. 1-6 3708 Planning and Installation

• It has a built-in diagnostic test that runs each time you power on or initiate a

restart at the control terminal. • It has a built-in, optional, extended diagnostic test program that is available with port external wrap testing. • It provides a one-year warranty and is supported by IBM service. Chapter 1. The 3708 and Its Advantages 1-7

Chapter 2. Operating Mode Functions

This chapter describes the functions that the 3708 provides in protocol conversion, protocol enveloping, and ASCII pass-through modes. Protocol Conversion Display Support In protocol conversion mode, the 3708 provides all the functions in IBM 3274 Configurati

• It provides a numeric lock function that reduces the chance of the end-user

entering non-nuinetic data when the application expects numeric data.. The 3708 allows the end-user to override this function by typing: Any upper case character or symbol into the numeric field. A blank into the first position in the numeric field. While the blank occupies the first position in the field, the user can type any character into the numeric field. • It provides type-ahead key queuing, that allows the user to enter new keystroke sequences on the keyboard while a preceding keyboard sequence is being processed. This function allows a user to request the next screen before the current screen is completely displayed. The user can turn type-ahead key queuing on and off. • It provides enhanced null/blank processing, that allows the user to use either the space bar or the cursor move keys to edit and separate fields. The 3708 allows trailing blanks or nulls to move off the end of a line when the user is inserting data in that line. When the data is sent to the host, the 3708 converts imbedded nulls to blanks. The user can turn eDhanced null/blank processing on and off. • It supports highlighting and color for certain classes of displays. Refer to IBM 3708 Network Conversion Unit Description for more information. Light-pen operations can be simulated using a Cursor Select key sequence. • It supports the following 3270 commands: Erase All Unprotected Erase/Write Erase/Write Alternate Read Buffer Read Modified Read Modified All Write. • It supports the following buffer formatting and control orders: Start Field Set Buffer Address Inset Cursor Program Tab Repeat to Address Erase Unprotected to Address. • It notifies the user when it detects a framing or parity error by updating the status line. To continue, the user must reset the display using the 3270 reset function. This function can be suppressed by configuring the nonstandard operating bit 5 to 1. Refer to "Non-Standard Operations" on page 14-3 for more information. • It allows the conttol terminal operator to display response-time statistics and error information, such as the alert log, at the control terminal. In addition, the response~time statistics and alerts can be displayed at the host using NetView or Network Logical Data Manager (NLDM) and the Network Problem Determination Application (NPDA). Full support for 3708 alerts is available only through NetView. 1-1 3708 Planning and Installation

Printer and Keyboard Printer Support

In protocol conversion mode, an ASCII printer or keyboard printer looks like an IBM 3287 Printer, Model I or 2 to the SNA host. The ASCII printer or keyboard printer can be configured to operate in three ways: System mode. The host sends print data to the printer, which is either an LU type I or an LU type 3. The output format for an LU type I printer is controlled by SNA character string (SCS) characters. For an LU type 3 printer, the output can be formatted or unformatted. Unformatted output is controlled by 3270 data stream compatibility (DSC) print orders. Local mode. A copy of the screen of a display that is operating in protocol conversion mode is printed at the printer. The host can start a local copy by sending a command, or the user of the display can select it with a print key sequence. When a printer port is configured for local mode, it cannot be used for LU type I or LU type 3 print operations. Shared mode. The printer is available for both system mode and local mode operation. A local copy can be performed whenever the printer is not being used for an LU type I or LU type 3 print operation. Keyboard printers operating in protocol conversion mode are supported as output devices and must be defined as printers. Up to 256 characters (8-bit data with no parity) can be used with an output device operating in L U type I SCS transparency mode. The 3708 supports the following input from a keyboard printer that is directly connected to the 3708: • Hold Print/Enable Print • Cancel Print (LU type I SCS only) • PAl and PA2 (LU type I SCS only). Multiple Logical Unit Support A printer connected to an auxiliary port on a display that supports remote access to its auxiliary port can be defined as a second LU on the 3708 port to which the display is connected. The printer can then be used in system mode, local mode, or shared mode. This support is referred to as multiple logical unit (MLU) support and operates only in protocol conversion mode. If a printer is connected to an auxiliary port on a display and is not defined to the 3708, the printer can be used only for screen copy operations that are initiated by the user. The user enters a predefined key sequence that the 3708 echoes back to the display. Input from devices that are connected to the auxiliary port of a display is not explicitly supported; any such input is assumed to be for the display. Chapter 2. Operating Mode Functions 2-3

In prptocol enveloping mode, the 3708 supports an ASCII end-user device as an LU

type 1 with a Network Terminal Option (NTO) appearance. The 3708 does not provide any device-specific support other than that provided by NTO for devices that are compatible with TWX 33/35. The application program must provide any device-specific support. The 3708 supports the following functions in protocol enveloping mode: • It mayor may not modify the ASCII data, depending on how the port is configured. The data can be modified by using a translate table, delay characters, substitution characters, and other options that are defined during configuration. If the data is translated from ASCII to EBCDIC, the 3708 can use one of two standard translate tables or a user-defined translate table. • It can provide a delay after a Carriage Return, Vertical Tab, Form Feed, or Horizontal Tab. • It can use either a default substitution character or a user-defined substitution character when it detects a data error. When it detects a parity error in a character, the 3708 can replace the character with the Parity Error Substitution character configured in the 3708. When it detects a framing error, the 3708 always replaces the framing error with the Parity Error Substitution character. • It can use up to five different turnaround characters, which are defined during configuration, to control communication. When the 3708 receives a line turnaround character from an end-user device, the 3708 sends data from the device to the host. Because the 3708 does not control the keyboard in protocol enveloping, users must know when they can and cannot enter data. A character string that tells the user when to enter data can be defined for each port. To define the character string, see "Send Read Prompt" on page 13-40. In addition, a port can be configured to enable the 3708 to echo characters that are entered at the keyboard. • It can provide for transparent data flow. The 3708 can support 256-character sets and output-only devices, such as printers and plotters. • It can allow the host to dial out to devices. For more information, refer to IBM 3708 Network Conversion Unit Description. ASCII Pass-Through In ASCII pass-through mode, the 3708 serves as a wire connection between an ASCII end-user device and an ASCII host. The host and the end-user device are responsible for data and protocol error checking. N~te: A programmable modem can be installed on a port configured as an ASCII host. The 3708 allows the user to dial out through the programmable modem in ASCII pass-through mode and gain access to an ASCII host, printer, or other device. 2-4 3708 Planning and Installation

The following table summarizes the functions that the 3708 provides.

Protocol Protocol ASCII Function Conversion Enveloping Pass-Through IBM 3178/3278/3279 Model 2, 3, 4, or 5, Display Standard n/a n/a Station emulation IBM 3287 printer, Models 1 and 2 emulation Standard n/a n/a Four color support (3279-2A and 3179 emulation) Optional n/a n/a Highlighting support Optional n/a n/a Light pen emulation Optional n/a n/a Type-ahead Optional n/a n/a Enhanced null/blank processing Optional n/a n/a User-defined terminals Optional n/a n/a 3270 status line emulation Standard n/a n/a Response time monitor (RTM) Standard n/a n/a Alerts (Alerts generated for ASCII pass-through are Standard Standard Standard transmitted to SNA hosts.) NTO-like function (LU type 1 NTO emulation) n/a Standard n/a Full duplex operations Standard Optional Standard Half duplex operations n/a Optional n/a Parity and framing checking Standard Optional n/a Ignore parity n/a Optional Standard Character echoplexing Standard Optional nja No character echoplexing n/a Optional Standard 128-ASCII-character support Standard Optional Optional 256-ASCII -character support n/a Optional Optional 256-ASCII-character support (LU type 1 SCS) Optional n/a n/a Choose one of two standard translate tables Optional Optional n/a User-defined translation table Optional Optional n/a No translation n/a Optional Standard 3708 accepts XON/XOFF pacing Optional Optional n/a 3708 transmits XON/XOFF pacing Optional Optional n/a LU type I SCS printer data stream support Optional n/a nja LU type 3 DSC printer data stream support Optional n/a n/a System, local, or shared printer support Optional n/a n/a MLU support (a printer attached to the auxiliary port Optional n/a n/a of a display.) Chapter 2. Operating Mode Functions 2-5

Autobaud/parity for 110 through 4800 and 9600 bps

Optional Optional Optional for downstream devices Line speeds up to 19200 bps Optional Optional Optional EIA 232C support for (SNA and ASCII) host Standard Standard Standard connection EIA 232C support for downstream device connection Optional Optional Optional EIA 422A support for downstream device connection Optional Optional Optional Selection of 3708 logon screens Optional Optional Optional 2-6 3708 Planning and Installation

Chapter 3. Host and ASCII Device Interfaces

SNA Hosts This chapter describes the connections between the 3708 and the hosts and between the 3708 and the ASCII end-user devices. The 3708 can be connected to as many as two SNA hosts using either point-to-point or multipoint links. It is defined as a separate physical unit (PU) to each SNA host link. In addition, the connection to the host can be direct, or it can be remote using a nonswitched (leased) line. Line speeds as high as 19200 bps can be used. SNA host connections use the EIA 232C interface. The 3708 uses the SDLC protocol to communicate with an SNA host, and it uses half duplex data transmission on either full duplex or half duplex communication facilities. If a particular end-user device will always be used with one specific SNA host, the 3708 port to which the device is connected can be defined to suppress the 3708 logon and/or host-selection screens. Because the service priority of the 3708 is in descending order, ports 10 and 9 are recommended for SNA host connections. Connect the first SNA host to port 10 and the second SNA host to port 9. The 3708 can be connected to an SNA host through any of the following: • IBM 3720 Communications Controller • IBM 37x5 Communications Controller • IBM 3710 Network Controller • IBM 43xx with an Integrated Communication Adapter • IBM 4701 Model 003 Finance Communication Controller (using Alternate Line Attachment adapter, SNA Primary to attach to the 4700) • IBM 4702 Branch Automation Processor (using the Alternate Line Attachment adapter, SNA Primary to attach to the 4700) • IBM 8100 System Data Link or Direct Attach • IBM System/36 Communications Attachment (using the 3274 Remote Attach Support) • IBM System/38 Communications Attachment (using the 3274 Remote Attach Support). Chapter 3. Host and ASCII Device Interfaces 3-1

For network management at the host, the following programs can be used:

• NetViewfully supports the 3708 alerts and response time monitor (RTM) data. NetView contains both Network Problem Determination Application (NPDA) and Network Logical Data Manager (NLDM). • Network Problem Determination Application (NPDA), Version 3 or later, supports only the specific and general cause codes of 3708 alerts. • Network Logical Data Manager (NLDM), Release 2 or later, supports response time statistics. The 3708 can be connected to multiple ASCII hosts using point-to-point links. The connection can be direct, or it can be remote using a nonswitched (leased) line. ASCII host connections use the EIA 232C interface. Line speeds as high as 19200 bps can be used. The speed used by the host.and the. speed used by the end-user device should be the same. Full duplex transmission must be used. ASCII End-User Devices The 3708 can be connected to ASCII end-user devices using either a direct or remote connection. End-user device connections use the EIA 232C interface or, for distances over 15 meters (50 feet), the EIA 422A interface. A remote connection can use either switched or nonswitched lines. Line speeds can be as high as. 19200 bps. Protocol Conversion Mode For protocol conversion mode, the 3708 supports various displays, printers, and keyboard printers. 3-2 3708 Planning and Installation

The 3708 provides default keyboard mappings for the following displays:l

• IBM 3101 Display Terminal Models 10, 12, 13,20,22, and 23 • IBM Personal Computer (PC) in 3101 emulation mode with standard 3101 keyboard functions • IBM PC with a color monitor running the IBM PC/HOST File Transfer and Terminal Emulator Program (FTTERM) • IBM PC with a monochrome monitor running the IBM PC/HOST File Transfer and Terminal Emulator Program (FTTERM) • IBM 3151 ASCII Display Station • IBM 3151 with cartridge to emulate IBM and DEC® terminals (Feature No. 8235) • IBM 3151 Connectivity Feature Cartridge (Feature No. 8525) • IBM 3151 with Expansion Feature Cartridge (Feature No. 8535) • IBM 3161 ASCII Display Station • IBM 3161 with Enhanced 3708 Attachment (Feature No. 8371) • IBM 3162 ASCII Display Station • IBM 3162 with 3708 Support Functions (Feature No. 8232) • IBM 3163 ASCII Display Station • IBM 3164 ASCII Color Display Station • IBM 3163/3164 VT100/3708 Emulation Cartridge (Feature No. 8313) • ADDS (Applied Digital Data Systems) Viewpoint® • Beehive™ ATL-078 • Data General Dasher® D210 Display Terminal • DEC® (Digital Equipment Corporation) Models VT52, VT100, and VT220 • FALCO 500® • Hazeltine 1500, ESPRIT I™, and ESPRIT IITM • Hewlett-Packard 2621B Interactive Terminal • Lear Siegler ADM 3A Dumb Terminal® • Northern Telecom Displayphone™ • ROLM Cypress, Cedar, and Juniper (connected through ROLM CBX II) • Teletype 5410 Asynchronous Display Terminal and 5420 Buffered Display • TeleVideo® 910 and 950 • WY-50® (Wyse 50) • Other terminals and personal computers emulating and compatible with one of the named devices. Appendix K, "Manuals for Default Protocol Conversion Displays" contains a list of sources for more information about these displays. Refer to Appendix M, End-User-Device Reference Cards Order Form for the reference cards. 1 The list of displays contains several trademarks and registered trademarks. Viewpoint is a registered trademark of Applied Digital. Data Systems, Inc. Beehive is a trademark of Beehive International. Dasher is a registered trademark of the Data General Corporation. DEC is a registered trademark of the Digital Equipment Corporation. ESPRIT I and ESPRIT II are trademarks of Esprit Systems, Inc. FALCO 500 is a registered trademark of Falco Data Products, Inc.. Dumb Terminal is a registered trademark of Lear Siegler, Inc. Displayphone is a trademark of Northern Telecom, Inc. TeleVideo is a registered trademark of TeleVideo Systems, Inc. WY-50 is a registered trademark of Wyse Technology. Chapter 3. Host and ASCII Device Interfaces 3-3

User-Defined Keyboard Mappings

In addition, the user can define as many as six user-defined keyboard mappings for other ASCII displays that have the following characteristics: • Operate in character mode using asynchronous full duplex communications • Use either EIA 232C interface or the EIA 422A signaling • Use standard .128-character ASCII (7-bit data with odd, even, or no parity) Note: The 3708 does not support Shift-In and Shift-Out. • Use duplex communications on a 2- or 4-wire communication facility • Position the cursor using one of the seven predefined cursor addressing classes (see page 15-8) • Provide settings for host echo instead of local terminal echo only • Use DC1 and DC3 as XON and XOFF for pacing. Printers and Keyboard Printers The 3708 supports ASCII printers and keyboard printers that have the following characteristics: • Use asynchronous duplex full communications • Use the EIA 232C serial interface • Use standard 128-character ASCII (7-bit data with or without parity) • Have a maximum line length of 132 characters • Support X I OD I for carriage return and X I OA I for Line Feed • Do not generate a Line Feed upon receipt of a Carriage Return • Do not generate a Carriage Return upon receipt of a Line Feed • Ignore delete characters (X I 7F I ) • Use DCl and DC3 as XON and XOFF for pacing • Operate at speeds from 110 bps to 19200 bps • Do not require any special sequences to be sent by the 3708 for initialization. Note: Keyboard printers operating in protocol conversion mode are supported only as printers. 3-4 3708 Planning and Installation (

Protocol. Enveloping Mode

For protocol enveloping mode, the 3708 supports ASCII devices that have the following characteristics: • Operate in character mode • Use either the BIA 232C interface or BIA 422A signaling • Use 8 bits, which mayor may not include parity • Use DCI and DC3 as XON and XOFF for pacing • Are compatible with TWX 33/35. ASCII Pass-Through Mode For ASCII pass-through mode, the 3708 supports ASCII devices that have the following characteristics: • Operate in character mode • Use either the BIA 232C interface or BIA 422A signaling • Use 8 bits, which mayor may not include parity. Chapter 3. Host and ASCII Device Interfaces 3-5

Planning for the 3708

This part provides the following planning information: Chapter 4. Planning Checklist ... Planning Configuration Parameters Device Information Form Network Planning Form Port Definition Form Chapter 5. Planning for Installation Specifications and Location Requirements Size and Weight ...... . Service and Setup Clearances Environment . . . . Interface Requirements Power Requirements . Branch Circuits and Grounding Power Plugs ...... . Safety and Security Considerations Chapter 6. Planning for Service ....... . Reviewing the Service and Warranty Options Service Options ..... . Warranty Options Remote Access Capability Installation Technical Assistance Replacement Elements and Remote Problem Assistance Calling for Service ..... . Calling the 800 Number Receiving Remote Assistance Hardware and Configuration Requirements Traces and Logs .... Locating the RID Number Chapter 7. Planning for Microcode Updates How to Register What to Expect ............ . How to Order ............ . What to Do with Outdated Cartridges Chapter 8. Planning for Central Site Configuration ...... . IBM 3708 Pluggable Cartridge with Central Site Configuration Hardware Requirements Software Requirements Software Options that Enhance CSC Configuration Downloads from an SNA Host Control Terminal Emulation 3708 Configuration Requirements .. Modem Configuration Requirements Technical Assistance . Ordering Information Chapter 9. Planning for File Transfer 4-1 4-2 4-3 4-4 4-5 5-1 5-1 5-1 5-1 5-1 5-2 5-2 5-2 5-3 5-5 6-1 6-1 6-1 6-1 6-2 6-2 6-2 6-3 6-3 6-4 6-4 6-4 6-5 7-1 7-1 7-1 7-1 7-2 8-1 8-1 8-2 8-2 8-3 8-3 8-3 8-4 8-5 8-5 8-5 9-1 Planning for the 3708

IBM PC/HOST File Transfer and Terminal Emulator Program

9-1 Benefits and Functions 9-1 Required Host Programs 9-2 IBM 3708 Plug-In Support 9-3 Technical Assistance 9-3 Ordering Information 9-3 Personal Services/PC 9-3 A User-Written File Transfer Program 9-3 Chapter 10. Planning for Cables 10-1 Cable Descriptions ...... 10-1 IBM-Supplied Cables 10-1 Non-IBM Supplied Cables 10-2 Examples of 3708 Cable Connections 10-2 SNA Host to a 3708 10-3 Remote: Using Modems .. . 10-3 Local: Using a Modem Eliminator or Null Modem 10-4 Local: Direct Connection Using an EIA 232C DTE Cable (8100 Only) 10-5 Local: Direct Connection Using a Host EIA 232C DTE Cable and a 3708 EfA 232C DCE Cable ........ 10-6 Local: Direct Connection Using a Host EIA 232C DCE Cable and a 3708 ErA 232C DTE Cable 10-7 ASCII Hosts and End-User Devices to a 3708 ...... 10-8 Remote: Using Modems . . . . . . 10-8 Local: Using Modem Eliminators and Null Modems 10-8 Local: Direct Connection Using a 3708 ETA 232C DTE Cable (Male - Male and Male - Female) . . . . . . 10-9 Local: Direct Connection Using a 3708 EIA 422A Cable 10-10 3708 Connection to the IBM Cabling System 10-11 3708 Problems Related to Cables or Equipment 10-12 Chapter 11. Ordering the 3708 11-1 Order Forms . . . . . . . . 11-1 3708 Planning and Installation

Chapter 4. Planning Checklist

This chapter provides a planning checklist to help prepare for the installation of the 3708. The steps in the planning process are: 1. Plan the 3708 network. The following section, "Planning Configuration Parameters" on page 4-2, contains the forms and information for planning the network. 2. Plan for the site and other physical requirements of the 3708. See Chapter 5, "Planning for Installation" for more information. 3. Plan for service. See Chapter 6, "Planning for Service" for more information. 4. Plan for microcode updates. See Chapter 7, "Planning for Microcode Updates" for more information. - 5. Plan for central site configuration. See Chapter 8, "Planning for Central Site Configuration" for more information. 6. Plan for file transfer. See Chapter 9, "Planning for File Transfer" for more information. 7. Plan for cables. See Chapter 10, "Planning for Cables" for more information. 8. Plan for the parts that need to be ordered. See Chapter 11, "Ordering the 3708" for more information. 9. When the site and configuration planning is complete, follow the procedures in Chapter 12, "Installation Procedures" to install the 3708 and to enter the configuration parameters. Chapter 4. Planning Checklist 4-1

Planning Configuration Parameters

Use the following procedures to plan the 3708 configuration: • Complete the Network Planning Form on page 4-4 to help visualize the physical connections to the 3708. • Complete the Port Definition Form on page 4-5 to help organize and plan the network connections for the terminals, hosts,and printers. "Protocol Conversion Mode" on page 3-2 lists the terminals that the 3708 supports. • After you have defined the types of devices (hosts, terminals, printers) that are connected to each port, plan the configuration parameters for each device. Follow the procedures in Chapter 13, "Configuration Procedures" to configure each port. Chapter 12 provides the following information about the parameters for each type of device: The screens that are displayed on the control terminal for each type of device The options that you can enter for each field on the screens. Before starting the configuration, you need the following information: Host configuration. Prepare the host system generation. Refer to IBM 3708 Network Conversion Unit Description for more information. Downstream devices. Gather information about XONjXOFF, line speed, parity, interface type (EIA 232C or EIA 422A), and line type (switched or leased) for the devices that you are connecting to the 3708. Refer to the user manuals for the devices for more information. For a list of device manuals, see Appendix K, "Manuals for Default Protocol Conversion Displays." Use the Device Information Form on page 4-3 to collect the information for each device. Communications network environment. When attaching devices to the 3708 through modems, telephone lines, and public access networks, you should be aware of certain parameters associated with the connection facilities that can affect the 3708 operation, such as XONjXOFF, parity, stop bits, and communication speed. 4-2 3708 Phullling and Installation

To plan each port before entering the configuration parameters at the control

terminal, use the configuration forms in Appendix C, "3708 Configuration Forms" to indicate the correct option for each configuration parameter. Appendix B, "3708 Configuration Example" contains an example configuration, that may be helpful when you are deciding what to enter on the configuration screens. Appendix A, "IBM-Supplied Configuration" contains the IBM-supplied configuration that is shipped with the 3708. This configuration allows you to connect a control terminal for initially configuring the 3708. Because the SNA host port is excluded, the IBM-supplied configuration is not an operating network configuration. Device Information Form Device Names 1 2 3 4 5 6 7 8 9 10 Use the Device Information Form to collect device-specific information for each port. Interface Type Switched or EIA 232C or Leased Line EIA422A Line Speed Parity XON/XOFF Chapter 4. Planning Checklist 4-3

Network Planning Form

The Network Planning Form (Figure 4-1) allows the planner to identify the hosts and end-user devices and the 3708 ports to which they connect. 10 9 1 8 ~ / 2 7 3708 V '\ 4 5 Figure 4-1. Network Planning Form To complete the Network Planning Form, do the following: 1. In each box, write the host or end-user device that connects to the 3708. The lines between the 3708 and the boxes correspond to the ports on the 3708. 2. In the blank beside each box, write the other port numbers with which the host or end-user device can communicate. Figure 4-2 on page 4-5 shows a completed example of the Network Planning Form. See Appendix B, "3708 Configuration Example" for details on the network configuration. 4-4 3708 Planning and Installation

2 (displa.y) 1

I8tr1 4201 I"ILU 2 (prinfer) I8~ PC-AT RlJnning FTTE~ 3(disp!ay)2 (d,splay) IB~ '12()1 I'1LU 3 (printer)2 (pr"n~r) SiVA lIosfA IBI1 3011 SNA 1105+8 IB~ J090 7 4 2 (diSplo.y) ASCII #osf 7 of VT100 10 fl 2 (prti?fer) Exclvded 10 3 (tf/splay) IB/'1 PC-XT 1.0 9 g 2 (pr/fller) -FHEIU'1 /ie.fer.s to the I81'1 PC/ Hos! hie Transfe.r and E,-"ula.+or Pr~l'Om Figure 4-2. Network Planning Form Example Pori Definition Form The Port Definition Form (Figure 4-3 on page 4-6) can be used to enter data for each port on the 3708. Figure 4-4 on page 4-7 and Appendix B, "3708 Configuration Example." illustrate completed forms for the example in Figure 4-2. Chapter 4. Planning Checklist 4-5

PORTS TO COMMUNICATE

# NAME WITH LOCAL REMOfE DIRECT/ MODEM NULL MODEM/ DESC. MODEMELIM. I 2 3 4 5 6 7 8 9 10 I 2 3 ~ 5 6 7 8 9 10 Figure 4-3. Port Definition Form 4 .. 6 3708 Plannil!g and Installation

PORTS TO COMMUNICATE

WITH /I !'

Chapter 5. Planning for Installation

This chapter provides the following information about planning ·a 3708 installation: • Specifications and location requirements • Interface requirements • Power requirements • Safety and security considerations. Specifications and Location Requirements Size and Weight This section provides information about the size, weight, environment, and power specifications for the 3708. The following table shows the weight and dimensions of the 3708. Weight 5.3 kg (11.7lb) without cartridge 5.6 kg (12.3 lb) with cartridge Width 400 mm (15.8 in.) Length 355 mm (14.0 in.) Height 105 mm (4.1 in.) Service and Setup Clearances Environment The following table shows the recommended service and setup clearances for the 3708. Front 600 mm Back 600 mm Sides 40 mm Note: If the 3708 is shelf-mounted in a 19-inch rack, center it in the rack for proper ventilation. Ventilation slots are located on both sides of the 3708. If the 3708 is table-mounted, allow 40 mm (1.5 in.) on each side for proper ventilation. The 3708 operates in normal business environments. The following table shows the environmental specifications. Relative Maximum Environment Temperature Humidity Wet Bulb Operating 100 to 40.60 C 8% to 80% 26.70 C (80 0 F) (500 to 1050 F) Non-Operating 100 to 51.7 0 C 8% to 80% 26.7 0 C (80 0 F) (50 0 to 1250 F) Storage 0.60 to 600 C (330 5% to 80% 0.6 0 to 29.4 0 C to 1400 F) (33 0 to 85 0 F) Shipment _400 to 60 0 C 5% to 100% 0.60 to 29.40 C (_400 to 1400 F) (330 to 85 0 F) Chapter 5. Planning for Installation 5-1

The 3708 uses two types of interfaces, EIA 232C and EIA 422A. The following

table shows the hosts and end-user devices with which each interface can be used. Host/Device Type SNA host ASCII host ASCII printer ASCII display Interface Type EIA 232C EIA 232C EIA 232C ASCII keyboard printer EIA 232C or EIA 422A EIA 232C or EIA 422A Power Requirements The following table shows the electrical specifications of the 3708. Phase Power Frequency Voltage range: Noniinal voltage: Single phase 0.1 kVA 50/60 Hz ± 3 Hz Low voltage (90 to 137 V) High voltage (180 to 257 V) Low voltage (120 V) High voltage (230 V) Power Cord Length 4.3 meters (14.1 feet), shipped with the 3708 Notes: 1. You can order a 1.5-meter (6-foot) power cord in addition to the cord that is shipped with the 3708. 2. High voltages are not available in the USA and Canada. Make sure that your site has the electrical power to match the order. Branch Circuits and Grounding A dedicated branch circuit of 15 amperes is recommended for the 3708. For safety and proper machine operation, each branch circuit must be grounded to a dedicated equipment ground, not to a neutral ground. The branch circuit must have an insulated grounding conductor that is equal to the size of the phase conductor and is tied to a common ground point at the distribution panel. A single insulated and isolated grounding wire should run from the distribution panel ground point to the service ground or to a suitable building ground. Conduit must not be used as the only means of grounding. 5-2 3708 Planning and Installation

Figure 5-1 shows, by country, which power plugs are shipped with the 3708. The

alphabetic references in this table refer to the power plugs shown in Figure 5-2 on page 5-4. Low- High- Low- High- Country Voltage Voltage Country Voltage Voltage Argentina • Japan • • Australia • Korea • Austria • Netherlands • Belgium • New Zealand • Brazil • Norway • Bulgaria • Peru • Canada • Poland • Chile • Portugal • Czechoslovakia • Rumania • Denmark • South Africa f) Finland • Spain • France • Sweden • Germany DR • Switzerland • Germany FR • Taiwan • Greece • United Kingdom • Hungary • United States • Ireland • Venezuela • Israel • Yugoslavia • Italy • Figure 5-1. Power Plugs by Country Chapter 5. Planning for Installation 5-3

Plug (3-D View) I Receptacle

Plug (3-D View) I Receptacle .@ @ ~ov~ e 125v 15A 16A !ov.@ 15A ~ .~ 250V Q 0 16A ~ @ • ~~ !ov~ @ 250V 13A 10A 0) XJ~ .~~ 250V 250V. 0 0 16A 10A • ~ (2) !ov~~ 250V 10A 16A ~ .. ~ © 250V 10A Figure 5-2. Power Plugs and Receptacles 5-4 3708 Planning and Installation

Safety and Security Considerations

Electrical grounding of the 3708 is essential for safety and proper machine operation, so be sure the power receptacle is properly grounded. If you have any questions about the grounding of the receptacle, contact an electrician. Since the 3708 is small and lightweight, one person can move it safely during installation or relocation. If the 3708 cables are not installed under a raised floor, be sure the cables are arranged so there is adequate space for people to move around the 3708 safely. The 3708 cables, particularly those for a direct connection using the EIA 422A interface, are not protected against lightning. They must not be placed outdoors. To ensure the physical security of the 3708, do the following: • Allow only authorized persons to press switches on the 3708 and to use the control terminal. • Use unique passwords for port access and control terminal functions rather than the default passwords. • Exclude control terminal access to public ports. Chapter 5. Planning for Installation 5-5

Chapter 6. Planning for Service

This chapter describes the 3708 maintenance service offerings, tells who to call for installation technical assistance, outlines how to get remote assistance for problems not solved by problem handling-procedures, and gives the location of the repair identification number. The 3708 problem determination and service procedures provide the following: • Comprehensive internal diagnostics • Only two replaceable elements, which are a base and a plug-in cartridge • Communication network management support by providing alerts and by collecting performance statistics • Control terminal support for configuration, monitoring, and problem determination for either local or remote connection • Remote assistance for diagnosing machine problems and for applying microcode fixes through a modem and phone line access that you provide. These features reduce the cost of maintenance and the problem resolution time. Reviewing the Service and Warranty Options Service Options Warranty Options This section describes various service and warranty options that are available for the 3708. The IBM Maintenance Agreement provides maintenance service options. The following service options are available: Service Option Description Customer on-site exchange IBM arranges for the delivery of an exchange unit to your location and for pick up of the failing unit. IBM on-site exchange An IBM representative comes to your location and exchanges a functioning unit for the failing unit. If you purchase the IBM on-site exchange option, you can also purchase optional periods of maintenance service, which extend the hours in which service is available. The warranty period is for 1 year and is serviced under the customer on-site exchange service option. However, you can select the IBM on-site exchange service option during the warranty period for an additional charge. Contact the local IBM branch office for more information on warranties and maintenance agreements. Chapter 6. Planning for Service 6-1

Remote Access Capability

The 3708 is designed for remote access by both you and IBM service representatives. For example, the network personnel using a control terminal from a remote location can access 3708 alert data and review error logs to perform problem determination. You can also use the control terminal to monitor data and signaling lines on the 3708's downstream ASCII ports. Remote assistance is part of the 3708 maintenance service offerings. It allows an IBM service representative to dial out to a 3708, to run extensive diagnostic tests, and to apply microcode fixes if necessary. Remote assistance can minimize outages that would otherwise require the unnecessary iep1acement of the base or cartridge and can minimize the delay in waiting to receive a new cartridge with updated microcode. To receive remote assistance, you must provide a modem and phone line access for the IBM service representative. Installation Technical Assistance Contact the marketing representative where the 3708 was purchased if you have technical questions about any of the following: • Ordering information for the 3708 base, cartridge, and cables • Installation • Configuration • System integration • Application/host programming considerations. Replacement Elements and Remote Problem Assistance Before calling for service, use the problem-determination procedures in IBM 3708 Network Conversion Unit Problem Determination to isolate the problem to a failing unit if possible. After completing problem determination, contact IBM for service as described in "Calling for Service" on page 6-3. To be eligible for this assistance, the 3708 must be either under warranty or covered by an active IBM service agreement. 6-2 3708 Planning and Installation

Calling for Service

Use the following telephone number to receive replacement units, existing microcode fixes (MCFs), or problem assistance: • In the continental United States or Puerto Rico, call the following number: 1 800 428-2569 (toll free) • In other countries, call the appropriate support group. Note: The telephone numbers are subject to change. If the number has changed, call the IBM marketing representative or the local IBM branch office. Calling the 800 Number When you call the 800 number, an IBM customer service coordinator briefly discusses your situation and asks for the type of machine, the machine serial number, the repair identification (RID) number (see page 6-5), the name of your company, and a phone number where you can be reached. The customer service coordinator also performs an entitlement check to determine the type of contract or warranty agreement in effect. The IBM customer service coordinator is not the IBM service representative for the 3708. If you wish to obtain existing microcode fixes (MCFs) for your level of microcode, the customer service coordinator will forward your request to the IBM service representative, who will make arrangements with you for the installation of the MCFs. If you have a problem and have successfully completed the problem determination procedures and isolated the problem to a unit, you are given instructions on how to receive a replacement unit. If you are unable to complete the problem determination procedures or if the procedures indicate a microcode problem, further assistance in problem determination will be provided. The information about the problem will be forwarded to a 3708 specialist who will call you back. The service representative will call you and either provide a solution for the problem or work with you to solve the problem. Chapter 6. Planning for Service 6-3

Receiving Remote Assistance

IBM can help through remote assistance if you are unable to resolve a 3708 problem using the procedures in IBM 3708 Network Conversion Problem Determination and if one of the following is true: (1) the 3708 is still under the I-year warranty, or (2) you have purchased IBM maintenance service. Remote assistance can include consultation with an IBM service representative for problem diagnosis by IBM through a remote connection (through a modem and phone line access that you provide). The network management personnel can also use the modem for configuration and problem management of devices that are connected to the 3708. Hardware and Configuration Requirements Traces and Logs For remote assistance, you must provide telephone facilities for a 1200 bps switched, auto-answer connection. This includes a modem with the following characteristics: • For the USA only, use a direct-connect, Bell 2I2A-compatible modem with operating speeds up to 1200 bps in full duplex mode when connected to the direct distance dial network. The modem must operate over a 2-wire switched line. For countries other than the USA, use a V.22-compatible modem. • EIA 232C compatible interface. Any downstream port used for remote assistance must be configured identically to port 3 as described in Appendix A, "IBM-Supplied Configuration." If this is not compatible with the normal mode of operation, reconfigure a port for that mode before receiving remote assistance by temporarily reinstating the IBM -supplied configuration. (Refer to IBM 3708 Network Conversion Unit Problem Determination for more information.) When not in use for remote assistance, the port is available for connection to an end-user device. The 3708 can be configured to deny access to the host from a port that is assigned to remote service. Microcode Fixes (MCFs), patches, and diagnostic traps are applied and stored in the base unit hardware (EEPROM). They are not stored in the cartridge. If you replace your base unit, you must have any MCFs, patches, or traps applied to the new base unit. As part of the problem determination process, the IBM representative often requires you to provide certain additional materials. The most frequently requested are an NCP Line Trace, a VT AM Buffer Trace, or a PT2 Trace of both upstream link and the failing downstream line. Please be prepared to obtain and provide these traces when requested. Also, you may be requested to obtain and provide copies of the 3708 Error Log and 3708 Alert Log at the time of failure. Making this information available can greatly enhance problem determination and speed the resolution of your problem. 6-4 3708 Planning and Installation

Locating the RID Number

The repair identification (RID) number enables the IBM customer service coordinator to perform an entitlement check to determine the warranty or service option that is in effect. Locate the machine type and repair identification (RID) number of the failing unit. The RID number is in the following locations: • Just above the power cord on the back of the base • On the cartridge. Apply the RID label that is shipped with the 3708 to the cartridge when the 3708 first arrives. • In the vital product data storage area on the logic board of the 3708 base. The RID number is displayed on the 3708 logon screens when logging on to the 3708. Generally, the RID number located on the cartridge and the base is the same as the RID number displayed on the 3708 logon screens. If they are not (they will differ if you have exchanged the base element), use the control terminal to enter the RID number located on the base (and cartridge) into the 3708's vital product area (EEPROM). EEPROM is a nonvolatile logic circuit in the 3708 that retains information regardless of whether the 3708 power is on or off. Maintaining the same RID number on the base, the cartridge, and within the 3708's vital product area ensures smoother and faster service if you need to exchange 3708 elements or need remote service for microcode. Chapter 6. Planning for Service 6-5

Chapter 7. Planning for Microcode Updates

This chapter describes the 3708 microcode update procedure. It includes how to register for microcode update notification, what to expect in the notification, how to order microcode updates, and what to do with outdated microcode. Note: The cartridge holds all of the 3708's operational microcode. This code cannot be downloaded from a host. Microcode fixes (MCFs) and patches are stored in the base unit and can be downloaded from the host. Refer to Chapter 8, "Planning for Central Site Configuration" for more information. How to Register What to Expect How to Order To register for microcode update notification, you MUST fill out the registration form that comes with the 3708 and send it to the address indicated on the form. You must fill out and send in this registration form to be notified of any microcode updates. After you send in your registration form, IBM 3708 Microcode Support personnel will notify you with Engineering Change (EC) Memos as new engineering changes for microcode become available. The memo gives you the new EC number for the microcode and a list of the improvements and corrections contained in the update. Even if you have not encountered any problems, it is recommended that you install the updated microcode level to prevent possible future problems that may occur because of any changes in your operating environment. To order microcode updates without charge do one of the following: 1. Fill out the IBM 3708 Enhanced-Cartridge Ordering Form that is attached to the notification memo and send this form to the address indicated on the back of the ordering form. No postage is necessary. 2. Call the 800 number shown below, and be ready to give your RID number, customer number, address, and your name or the name of a person to contact. If you reach a recording when you call, please leave a message on the recorder and someone will return your call as soon as possible. If you have questions about receiving replacement cartridges: • In the continental United States or Puerto Rico, call the following number: 1 800 247-7118 (ton free) • In other countries, call the appropriate support group. Chapter 7. Planning for Microcode Updates 7-1

What to Do with Outdated Cartridges

The new microcode will be accompanied by a copy of 3708 Enhanced Cartridge Receive/Exchange/Re~urn Instructions. The instructions tell you how to do the , following: 1. Install the new 3708 microcode 2. Return the old cartridge by: a. Packing the old cartridge in the shipping carton used to send you the new microcode. Please be sure the RID number is identified on all cartridges being returned. b. Attaching the prepaid mailing label enclosed in the carton c. Mailing the old cartridge within 5 working-days of receiving the new microcode. To receive future releases of updated microcode, you must return outdated cartridges to ffiM. 7-2 3708 Planning and Installation

Chapter 8. Planning for Central Site Configuration

This chapter provides planning information about IBM 3708 Feature 3525 (pluggable Cartridge with Central Site Configuration), Feature 3525 consists of a plug-in cartridge and a set of diskettes. Together, the cartridge and the diskettes allow you to manage and distribute configuration updates and microcode fixes to 3708s in a network from a central location. This feature eliminates the task of entering repeatedly the same configuration or MCF /Patch data into all 3708s in a network. IBM 3708 Pluggable Cartridge with Central Site Configuration IBM 3708 Central Site Configuration (CSC) uses the IBM PC to support configuration and Microcode Fix (MCF) management for the IBM 3708 Network Conversion Unit. For central site configuration, you must install the 3708 Feature 3525 plug-in cartridge. Central site configuration provides the following advantages: • A single data base of configuration information for all of the IBM 3708s in an installation • Menu-driven, user-friendly facilities for the creation, replication, and modification of IBM 3708 configuration information including these features: Port definition for host links and downstream terminals User-defined terminal definitions User-defined translate table definition. • A check of configuration information as it is entered and a warning to the user if potential errors exist • Configuration summary screens, including a quick reference port summary, a detailed port summary, a host configuration summary, and printer configuration summary • A method to retrieve existing configuration information from an IBM 3708 through a downstream port • A method to load configuration information through a downstream port or the SNA host link with NetView or NCCF V2R2 • A method to retrieve a microcode patch area from a 3708 that has been upgraded by IBM and the ability to distribute the microcode patch area to other 3708s in the network • Item-specific help screens and an online user's guide. Chapter 8. Planning for Central Site Configuration 8-1

The following hardware is required for central site configuration:

• A 3708 with Feature 3525 (pluggable Cartridge with Central Site Configuration) Note: Central site configuration is available with 3708 Feature 3525 only. • An IBM PC with: - A 5.25-inch diskette drive A fixed disk An IBM Color/Graphics or Monochrome adapter attached to an 80-column display A minimum of 512K bytes of storage (640K bytes of storage are required if the PC is to run in control terminal mode). You can use an IBM Personal System/2. To run CSC on the Personal System/2, you must first convert the 5.25-inch diskettes shipped with the CSC Cartridge to the 3.5-inch format. If you plan to perform central site configuration through one of the 3708's downstream ports, you will need: • An asynchronous communications adapter operating in primary mode • A normal voice-grade, switched communications line (for switched connections only) • Modems (for switched connections only). A manual-dial Bell 212A-compatible or auto-dial modem that supports the . Attention Command Set and result codes, such as an IBM PC 2400 bps or IBM 58422400 bps Modem is required for switched connections. Modem eliminators, null modems, or 3708 DTE cables may also be used to attach the IBM PC to the 3708. For a description of modem connections as well as modem eliminator, null modem, and 3708 DTE cabling configurations, refer to, "ASCII Hosts and End-User Devices to a 3708" on page 10-8. Software Requirements The following software is required for central site configuration: • IBl\l PC DOS Version 2.0 or later • eZ-VU II Runtime Facility Version 2 (6317025). 8-2 3708 Planning and Installation

Software Options that Enhance esc

The following features are enhanced by the 3708 central site configuration feature and other network software options. Configuration Downloads from an SNA Host The IBM 3708 central site configuration aid can prepare configuration information in the form of NetView CLISTs for downloading through the SNA host link to the IBM 3708. NetView and NCCF Version 2 Release 2 support this method of transfer. The file transfer software support that sends the CLIST from the IBM PC to the SNA host must be provided by the end-user. For example, the IBM PC/HOST File Transfer and Terminal Emulator Program, FTTERM, (6476052) can be installed in the IBM PC to upload CLIST files to the SNA host. New 3708s with the CSC feature have port 10 defined as an active host port with the following characteristics: Option Station Address NRZI Data Encoding Permanent Request to Send Line Speed Line Type Field Length (2) (1) (1) (2) (1) Port 10 X'08' 1 (Yes) o (No -- Use Controlled Request to Send) 00 (External Clocking) L (Leased) This configuration allows new 3708s to be configured remotely from the host site. For multipoint lines, no other devices on the line can have SDLC Station Address of X '08'. If two or more 3708s are to be installed on a single line, each 3708 needs to be configured from the host one at a time. The SDLC Station Address X' 08 ' should be reserved as a utility address because 3708 hardware or software errors and user interaction can temporarily or permanently re-instate the IBM-supplied configuration. If the host line parameters are not compatible with the user's environment, new 3708s can be configured for host line characteristics at a main site, shipped to remote locations, and configured over the SDLC links. Control Terminal Emulation The 3708 control terminal diagnostic routines can be accessed through the use of the IBM PC and the central site configuration aid running in control terminal mode. In this mode, the IBM PC can retrieve the alerts and error logs. IBM software products that can support this feature are FTTERM, and the IBM 3101 Emulator Program (6024042). Notes: 1. If you plan to use your PC as a control terminal for the 3708 and you want CSC to log you on as a control terminal automatically, you must have the FTTERM or the IBM 3101 Emulation program installed. The emulation program must reside in the same directory on your fixed disk as the central site configuration program. 2. The IBM PC must have 640K bytes of memory to support this function. Chapter 8. Planning for Central Site Configuration 8-3

3708 Configuration Requirements

If central site configuration is perfonned through one of the 3708's downstream ports or the IBM PC is to run in control terminal mode, at least one downstream 3708 port must be dermed for the following parameters: • Port Excluded = N • Logon Screens Excluded = N • Terminal Type Screen (C2) = y • Host Selection Screen (C3) = Y • Control Terminal Access = Y • Password Retry Limit = 3 or greater • Transmit XONjXOFF = 1 • Line speed = 1,2,4,5,6,8, 10, 12, or 19 (110, 150, 300, 600, 1200,2400,4800, 9600 bps, or Autobaud) • Device Class = 1 (Keyboard Display) • Operating Mode = 1 or 2 (protocol Conversion or Dynamic) • Interface Type = 0 (EIA 232C) • Parity = 2, 3, or 6 (Odd, Even, or Autoparity) • Receive Queue Size = M or L • Bits/Character = 7 • Auto On-Hook = 1 (for switched lines) • Send Answertone = 0 (for switched lines) • Full Duplex Line = 1 • Echoplex = 1 • Pennanent Request to Send = 1. Note: Ports 3 and 7 in the IBM-supplied configuration for the 3708 are compatible with central site configuration. Refer to Chapter 13, "Configuration Procedures" for a complete description of these and other 3708 configuration parameters. 8-4 3708 Planning and Installation

Modem Configuration Requirements

If modems are used, the modem at the PC and the modem at the 3708 must be configured as follows: • Modems detect a change in Data Terminal Ready (DTR) signal and go on hook when DTR drops. • Data Set Ready (DSR) is raised only when a connection is established (not applicable for internal modems). • Carrier Detect shows whether or not Carrier is on. • Modems use the Attention Command Set and send the modem responses in words (verbose mode) and not in number codes (terse mode). • PC modem does not answer incoming calls. • The 3708 modem does answer incoming calls. • Modems do not echo characters. • Modems do not take over flow control (that is, the modem does not strip out XONjXOFF characters from the IBM PC or the IBM 3708). Technical Assistance See your IBM representative for assistance with problems related to the central site configuration aid. Ordering Information The Pluggable Cartridge with Central Site Configuration can be ordered with an IBM 3708 Network Conversion Unit. Spare Pluggable Cartridges with Central Site Configuration can be ordered by part number. A set of S.2S-inch, double-sided, double-density diskettes containing the central site configuration aid is included with each Pluggable Cartridge with Central Site Configuration feature. Chapter 8. Planning for Central Site Configuration 8-5

Chapter 9. Planning for File Transfer

This chapter describes 3708 support for the following file-transfer programs: • IBM PC/HOST File Transfer and Terminal Emulator program (PN 6476052) • IBM Personal Services/PC program (Version 1.4 or higher) • A user-written file transfer program. IBM PC/HOST File Transfer and Terminal Emulator Program This section describes the function of the IBM PC/HOST File Transfer and Terminal Emulator Program (FTTERM). It also describes the benefits of using FTTERM and lists the environments under which it works. Benefits and Functions FTTERM is a licensed program that supports IBM PCs communicating with an IBM SNA host through a 3708. The program gives the user of an IBM PC full-screen 3270 terminal emulation and file transfer capability when operating in protocol conversion mode with the 3708. The connection between the IBM PC and the 3708 is through the IBM PC's asynchronous communication adapter. An IBM PC running FTTERM can also emulate an IBM 3101 terminal and connect to the 3708 in protocol enveloping mode. This connection provides access to asynchronous applications at the IBM SNA host that formerly interfaced to the Network Terminal Option (NTO) licensed program in the 37x5. The IBM PC can also operate through the 3708 to an ASCII/asynchronous host connected to another port on the 3708. In addition, FTTERM can access network services independent of the 3708. The features of the PC/HOST File Transfer and Terminal Emulator program are summarized as follows: • Provides IBM PC file transfer capability both to and from the IBM host 3270 personal computer file-transfer programs while operating in protocol conversion mode with the 3708. See "Required Host Programs" on page 9-2 for the program product numbers. • Provides full-screen 3270 emulation, status line support, and four color or highlighting while operating in protocol conversion mode through a 3708. • Supports the 3708 feature that allows a printer and a display to share a single port in protocol conversion mode. • Provides 3101 emulation (character mode only) to: Asynchronous applications at an IBM host in protocol enveloping mode An ASCII/asynchronous host connected to another port on the 3708 - Online information services, such as the IBM Information Network. Chapter> 9. Planning for File Transfer 9-1

• Allows an IBM PC user to redefine the PFandPA keys to 3270 AID functions,

• Provides a resident option that permits the IBM PC user to load FTTERM only once a day. • Allows concurrent file transfer and IBM PC DOS application operation. • Provides key sequence switching between the IBM PC DOS session, the host session, and file transfer operation without disconnection or loss of the IBM host session. • Supports error checking and automatic retransmission of file transfer. • Provides status messages for monitoring the progress of the file transfer. • Supports the following text or binary file-transfer operations: An IBM host file to an IBM PC DOS file or to a personal computer printer An IBM PC DOS file to a host file or to an IBM PC printer An IBM host screen to a host file, to an IBM PC DOS file, or to an IBM PC printer An IBM PC DOS screen to a host file, to an IBM PC DOS file, or to an IBM PC printer Multiple files without operator intervention. • Provides an online help facility. • Provides for stored keystroke sequences for repetitive operations, such as a modem-dialing keystroke sequence. • Supports the PROFS PC Support Feature, Version 2 (5664-309) while running FTTERM. This support provides file transfer capability both to and from the host PROFS while operating in protocol conversion mode with the 3708. Required Host Programs File transfers are performed with the following IBM 3270 PC file-transfer programs installed at the host. One of the following programs must be· installed at the host to . run FTTERM. Environment MVSjTSO VMjSP CICS (MVS and VSE) VSE 2.11 Host File Transfer Program 5665-311 5664-281 5798-DQH 5666-316 1 The PC/HOST File Transfer and Terminal Emulator program works with the integrated Intelligent Work Stations (IWS) program, which is shipped with VSE, Release 2.1 and higher. 9;.2 3708 Planning and Installation

IBM 3708 Plug-In Support

The 3708 plug-in cartridge supports the PC/HOST File Transfer and Terminal Emulator Program with the following two types of terminals: • IA - IBM PC/FTTERM COLOR. Customers using FTTERM with color monitors would select this option. • IB - IBM PC/FTTERM MONO. Customers using FTTERM with monochrome monitors would select this option. Technical Assistance Eligible customers can receive installation and usage assistance from the IBM Workstation Customer Assistance Center (WSCAC). Assistance is provided through ASKINFO, an electronic data base that provides current information on selected products. Assistance is also provided by telephone call back. When requesting assistance from the ASKINFO personnel, your customer technical coordinators should use the key word FTTERM for search inquiries and questions. The ASKINFO personnel will then call you back. Contact the IBM marketing representative to determine if you are eligible to receive ASKINFO support. Ordering Information Both a 5.25- and a 3.5-inch diskette are included with a user's guide when you order the PC/HOST File Transfer and Terminal Emulator Program. Ask the marketing representative to order feature number 0914 of 5875-MMA. Personal Services/PC Personal Services/PC is an office-oriented mail management program for the IBM personal computer. It provides a comprehensive and easy-to-use set of office systems functions, such as automatic dialing, receiving and transmitting mail, and printing and viewing documents. Document transfer to the host is performed in conjunction with the DISOSS program product. Personal Services/PC is supported by the 3708 in protocol enveloping mode. For more information about the Personal Services/PC, refer to How To Use Personal Services/PC, SC30-3316. A User-Written File Transfer Program For information on developing a user-written file transfer program for personal computers connected to a 3708, refer to IBM 3708 Network Conversion Unit Description. Chapter 9. Planning for File Transfer 9-3

Chapter 10. Planning for Cables

This chapter provides information to help you plan for the cables and the cable connections for the 3708. Cable Descriptions This section describes the cable requirements for the 3708. IBM-Supplied Cables The part numbers for the cables are listed in the following table according to length, interface, and application. Host devices Interface (See note 2.) Cable Type (See note 1.) Connectors 3 meters (10 feet) 8 meters (25 feet) 15 meters (50 feet) Up to 122 meters (400 feet) (See note 4.) Between 122 meters (400 feet) and 1219 meters (4000 feet) (See note 4.) 38 meters (125 feet) (See note 5.) Notes: SNAand SNA and ASCII hosts, ASCII hosts, ASCII printers ASCII printers and displays and displays EIA 232C EIA232C DCE DTE Male-Male Male-Female PN 6405390 PN 6405393 PN 6405391 PN 6405394 PN 6405392 PN 6405395 SNA and ASCII hosts, ASCII printers ASCII displays and displays (See Dote 1) EIA232C EIA 422A DTE DTE Male-Male Male-Male PN 6405421 PN 6405422 PN 6405423 PN 6405396 PN 6405397 (See note 3.) PN 6405398 1. A 3708 DCE cable connects a 3708 to a modem, a modem eliminator, or a null modem. A 3708 DTE cable directly connects a 3708 to a host or an end-user device. 2. The IBM EIA 422A cables can only be used with an IBM 3101, an IBM 3151, an IBM 3161, an IBM 3162, an IBM 3163, an IBM 3164, or a compatible terminal. 3. Cable PN 6405397 contains surge-suppressing diodes. 4. Variable-length cable is available only in the USA and A/FE countries. See a marketing representative for the availability in your country. 5. The fixed-length cable PN 6405398 is available only in EMEA countries. See the marketing representative for the availability in your country. 6. To make your own cables, refer to Appendix D, "Cable Requirements." Chapter lO. Planning for Cables 10-1

Non-IBM Supplied Cables

Recommendations for cables not supplied by IBM are as follows: • Do not use 25-pin conductor cables under any circumstances. • Use cables with the conductors as described in Appendix D, "Cable Requirements. " Examples of 3708 Cable Connections This section provides examples for cable connections from SNA hosts to a 3708 and from ASCII hosts and end-user devices to a 3708. The examples show connections using modems, null modems, and modem eliminators. See the glossary for a definition of these terms. In these examples, the following meanings apply: F M Blank 10-2 3708 Planning and Installation Female Male Device dependent.

SNA Host to a 3708

This section describes the ways that the 3708 can connect to an SNA host. Remote: Using Modems 3708 F 1M SNA Host 3705 PN 6405390 3725 PN 6405391 4300lCA PN 6405392 4700 3708 DCE Cable M I F 17 F I M Host DCE Cable S/38 Modem Modem 3720 8100 S/36 3710 Notes: 1. The 3708 DeE cable length must not exceed 15 meters (50 feet). 2. The host may use special connectors. If you have this configuration, use the cables that are provided with the host. 3. Configure the 3708 SNA host definition option Line Type for leased connection (LINE TYPE = L). Chapter 10. Planning for Cables 10-3

Local: Using a Modem Eliminator or Null Modem

3708 FIM 8NA Host PN 6405390 3705 3725 PN 6405391 4300lCA PN 6405392 4700 3708 DCE Cable Modem Host DCE Cable 8/38 M I F Eliminator or F 1M Null Modem 3720 8100 8/36 3710 Notes: 1. The host may use special connectors. If you have this configuration, use the cables that are provided with the host. 2. Ensure that the connector genders are correct. 3. The wiring of the modem eliminator or null modem must match that of the 3708 OTE cable described in "Minimum Connections Required for SNA Host OTE Cables, Modem Eliminators, or Null Modems" on page 0-7. 4. If the modem eliminator redrives the signal, then each cable segment must not exceed 15 meters (50 feet). Otherwise, the combined cable length must not exceed 15 meters (50 feet). 5. Clocking is required, and may be provided by one of three different methods: Clocking from the 3708 The 3708 can provide clocking for all line speeds that the 3708 supports. If this method is chosen, then the modem eliminator or null modem must not provide clocking. Configure the 3708 SNA host definition option Line Speed for the desired speed, and configure the host for external clocking. Clocking from the host Some hosts can provide clocking for some line speeds that the 3708 supports. If this method is chosen, then the modem eliminator or null modem must not provide clocking. Configure the host for the desired clocking speed, and configure the 3708 SNA host definition option Line Speed for external clocking (option 00). Clocking from the modem eliminator or null modem Some modem eliminators or null modems can provide clocking for some line speeds that the 3708 supports. If this method is chosen, then set the modem eliminator or null modem for the desired speed, configure the host for external clocking, and configure the 3708 SNA host definition option Line Speed for external clocking (option 00). 6. Configure the 3708 SNA host definition option Line Type for a leased connection (LINE TYPE = D). 10-4 3708 Planning and Installation

Local: Direct Connection Using an EIA 232C DTE Cable (8100 Only)

PN 6405393 PN 6405394 SNA Host PN 6405395 3708 F 1 MI-l ---------------11 F I M 8100 I 3708 OTE Cable I Notes: 1. The cable length must not exceed 15 meters (50 feet). 2. The host has standard 25-pin D connectors. 3. Clocking should be provided from the 3708. Configure the 3708 SNA host definition option Line Speed for the desired speed and configure the 8100 for external clocking. 4. Configure the 3708 SNA host definition option Line Type for a direct connection (LINE TYPE = D). Chapter 10. Planning Jot Cables 10 ... 5

Local: Direct Connection Using a Host EIA 232C DTE Cable and a 3708 EIA 232C DCE

Cable 8NA Host 3705 PN 6405390 3725 PN 6405391 4300lCA F 1M 3708 DCE Cable I MJ F I Host DTE Cable 4700 3708 8/38 3720 8/36 3710 Notes: 1. The host DTE cable is sometimes called a direct-connect or direct-attach cable. 2. The combined cable length must not exceed 15 meters (50 feet). 3. The host may use special connectors. If you have this configuration, use the cables that are provided with the host. 4. Ensure that the connector genders are correct. 5. The host system must be configured to provide clocking. The 3708 must be configured for external clocking. (Choose 00 for the 3708 SNA host definition option Line Speed.) For the 3705, this particular configuration is not supported, except by RPQ number EHOI70. For the 3720, the NCP gen must have CLOCKING = EXTERNAL, ATTACH = DIRECT, and SPEED = (the desired line speed, 2400 bps or greater). The actual line speed is configured by the MOSS. A 3725 Internal Clock Card ("ICC Card") feature is required for this configuration. For the 3725, the NCP gen must have CLOCKING = EXTERNAL, ATTACH = DIRECT, and SPEED = (the desired line speed, 2400 bps or greater). The actual line speed is determined by jumpers on the 3725 LAB board. A 3725 Internal Clock Card ("ICC Card") feature is required for this configuration. 6. Configure the 3708 SNA host definition option Line Type for a direct connection (LINE TYPE = D). 10;.6 3708 Planning and Installation

Local: Direct Connection Using a Host EIA 232C DCE Cable and a 3708 EIA 232C DTE

Cable SNA Host 3705 3725 PN 6405393 4300lCA PN 6405394 4700 F 1M 3708 DTE Cable FJ M Host DCE Cable 5/38 3708 3720 8100 5/36 3710 Notes: 1. The combined cable length must not exceed 15 meters (50 feet). 2. The host may use special connectors. If you have this configuration, use the cables that are provided with the host. 3. Ensure that the connector genders are correct. 4. Clocking must be provided by the 3708 by configuring the 3708 SNA host definition option Line Speed with the desired speed (specifically, this parameter must not be 00). The host system should be configured for external clocking. For the 3705, 3720, or 3725, the NCP gen must have CLOCKlNG=EXTERNAL, ATTACH = MODEM, and SPEED = (the desired line speed). The actual line speed is determined by the clock rate of the 3708. A standard external modem cable should be connected to the communications controller. 5. Configure the 3708 host definition option Line Type for a direct connection (LINE TYPE = D). Chapter lO. Planning for Cables 10-7

ASCII Hosts and End-User Devices to a 3708

This section describes the ways that the 3708 can connect to ASCII hosts and end-user devices. Remote: Using Modems 3708 F 1M. PN·6405390 PN 6405391 PN 6405392 3708 DCE Cable MI F Modem /' Modem ASCII FI M Device Cable I ASCII Device Note: Check the gender and the pin configuration of the equipment's interface before ordering cables. Local: Using Modem Eliminators and Null Modems 3708 F 1M PN 6405390 PN 6405391 PN 6405392 3708 DCE Cable Notes: Modem MI F Eliminator or Null Modem ASCII Device Cable ASCII FI M I Device 1. Check the gender and the pin configuration of the equipment's interface before ordering cables. 2. The wiring of the modem eliminator or null modem must match that of a 3708 DTE cable. (See "Minimum Connections Required for Asynchronous ASCII DTE Cables, Modem Eliminators, or Null Modems" on page D-9.) 3. If the modem eliminator re.drives the signal then each cable segment must not exceed 15 meters (50 feet). Otherwise, the combined cable length must not exceed 15 meters (50 feet). 10·8 3708 Planning and Installation

Local: Direct Connection Using a 3708 EIA 232C DTE Cable (Male - Male and Male -

Female) PN 6405393 PN 6405394 PN 6405395 37081 F 1MI-I ______ 3_70_8_D_T_E_C_a_b_le _____ ~1 F I M I ~~~ I PN 6405421 PN 6405422 PN 6405423 37081 F 1MI-I ______ 3_70_8_D_T_E_C_a_b_le _____ ~1 MI F I ~~~~.I Note: Check the gender and the pin configuration of the equipment's interface before ordering cables. PN 6405393 PN 6405394 3708 F 1M 3708 DTE Cable F 1M ASCII Device Cable ASCII Device Notes: 1. The combined cable length must not exceed 15 meters (50 feet). 2. Check the gender and the pin configuration of the equipment's interface before ordering cables. Chapter 10. Planning for Cables 10-9

Local: Direct Connection Using a 3708 EIA 422A Cable

PN 6405396 PN 6405397 PN 6405398 3708 F I M, 3708 422 Cable Notes: 3101 3161 ,MI F 3162 3163 3164 1. The 3708 supports a direct connection using the EIA 422A interface to the following IBM terminals: • IBM 3101, Model 13 • IBM 3101, Model 23 • IBM 3151 Model 310/410 • IBM 3161, Model 12 • IBM 3162, Model 12/32 • IBM 3163, Model 12 • IBM 3164, Model 12. 2. The length of the cable must not exceed 122 meters (400 feet) unless surge suppressing diodes are installed, in which case the length can be up to 1219 meters (4,000 feet). 3. Because there is no standard for the EIA 422A pin connections,IBM does not supply a cable for non-IBM ASCII terminals. 4. The ends of the EIA 422A cable are not identical. The 3708 end of the cable (marked V.ll on the IBM manufactured cable) has 6 pins and the terminal end has 4 pins. 10-10 3708 Planning and Installation

3708 Connection to the IBM Cabling System

This diagram. shows the cable connections from the 3708 to an IBM cabling system. Multi-Function Attachment Cable (PN8310553) IBM Cablin S stem Wiring Closet r------, Terminal Notes: Wiring Rack 1. Terminal support includes: • IBM 3101, Model 13 • IBM 3101, Model 23 • IBM 3151 Model 310/4lO • IBM 3161, Model 12 • IBM 3162, Model 12/32 • IBM 3163, Model 12 • IBM 3164, Model 12 IBM 3708/Cabling System Attachment Cable SNA Host 2. The multi-function attachment cable (PN 83lO553) is approximately 2.4 meters (8 feet) in length and may be ordered through normal local area network (LAN) channels. 3. A description of the 3708/Cabling System Attachment cable is contained in Appendix D. Note: This cable is NOT available from the IBM Corporation. 4. The connection between the 3708 and SNA host may be accomplished with one of the host cabling configurations described in this book. 5. Maximum cable path to the 3708 from the terminal is 1220 meters (4000 feet). For more information on the IBM Cabling System, refer to IBM Cabling System Planning and Installation Guide, GA27-3361, and Using the IBM Cabling System with Communication Products, GA27-3620. Chapter 10. Planning for Cables 10-11

3708 Problems Related to Cables or Equipment

. An incorrectly wired cable or incorrectly operating eqUipment (modem, modem eliminator, host, or end-user device) that is connected directly to a 3708 port can prevent the 3708 from operating. This problem occurs if the cable or equipment applies a signal to one of the following port connector pins: 2,4, 12, 14, 18, 20, 21, 23, or 24. Example 1: ROLM DTI users must ensure that the DTI is configured correctly and that the DTI switch SI-1 is set to OPEN (No). Otherwise, the DTI applies a signal to pin 20 of the 3708, which may prevent the 3708 from turning on. Recommended switch setting for the ROLM DTI are as follows: Switch #1 (SI): Forced DTR On Carrier Detect and CTS Display Audible Signal Enabled Terminal/Computer" Option Originate Answer/Answer Off Hook Control Switch Slide Switch (S3): Modem/Terminal Option OPEN (No) Either OPEN or CLOSED Either OPEN or CLOSED OPEN (TERMINAL) CLOSED (ANSWER) OPEN TERMINAL Example 2: IBM 5841 users must set configuration switch 8 (Data Set Ready option) to OFF. Setting this switch to ON causes the modem to hold Data Set Ready high (active) at all times. If the 3708 port is switched, and Data Set Ready is active all the time, the 3708 does not enable the port. To avoid signals on pins 2, 4, 12, 14, 18, 20, 21, 23, or 24, it is recommended that 25-pin conductor cables not be used. Example 3: Some synchronous modems and modem sharing devices do not hold the TXD line at a MARK level after RTS is dropped. This prevents devices on the same multi-drop line from communicating with the host. The problem occurs when the line is configured for NRZI data encoding. The problem can be prevented by doing one of the following: • Configure the modem/modem sharing device to hold the TXD line at a MARK level when RTS is dropped • Configure the line for NRZ data encoding. 10-12 3708 Planning and Install/ltion

Chapter 11. Ordering the 3708

Order Forms This chapter provides ordering forms to help you order the 3708 and its accessories. The following table shows the items that are required for the 3708. All of these items can be ordered from your Marketing Representative. Description 3708 base, Model 001 (See note 1.) 3708 cartridge (See note 2.) 3708 cartridge with Central Site Configuration (See note 2.) 3708 manuals Planning and Installation Description Problem Determination End-User Reference Terminal Reference Cards, as needed Notes: Order System AAS (See note 4.) AAS AAS AAS AAS AAS AAS AAS 1. The following items are shipped with the 3708 base: • 4.3-meter (14 feet) power cord • EIA 232C wrap plug for diagnostic testing Order Number Machine type 3708 Feature number 3524 Feature number 3525 GA27-3766 GA27-3768 GA27-3767 GA27-3765 See note 3. • IBM 3708 Network Conversion Unit Setup, GA27-3611 • IBM 3708 Network Conversion Unit Problem Report, GA27-3638 • IBM 3708 Network Conversion Unit Address Registration Form. Quantity 2. A 3708 Cartridge Feature must be ordered with each 3708 base. If you do not specify Feature Code 3524 or 3525, your order for a 3708 base unit will not be processed. 3. Refer to Appendix M, "End-User-Device Reference Cards Order Form" for the order numbers of reference cards for end-user devices. 4. AAS is the Advanced Administrative System. Chapter 11. Ordering the 3708 11-1

The following table shows the cables that are additional or optional for the 3708.

See Chapter 10, "Planning for Cables" for information about selecting the appropriate cables. All of these items can be ordered from your Marketing Representative. Order Order Description System Number Quantity EIA 232C DCE male - male 3 meters (10 feet) MES PN 6405390 8 meters (25 feet) (See note 2) 15 meters (50 feet) MES PN 6405391 MES PN 6405392 EIA 232C DTE male - female 3 meters (10 feet) MES PN 6405393 8 meters (25 feet) MES PN 6405394 15 meters (50 feet) MES PN 6405395 EIA 232C DTE male - male 3 meters (10 feet) MES PN 6405421 8 meters (25 feet) MES PN 6405422 15 meters (50 feet) MES PN 6405423 EIA 422A DTE male - male ** Up to 122 meters (400 feet) MES Specify the length required. PN 6405396 PN 6405396 PN 6405396 PN 6405396 PN 6405396 EIA 422A DTE male - male ** Between MES 122 meters (400 feet) and 1219 meters (4000 feet) Specify the length required. PN 6405397 PN 6405397 PN 6405397 PN 6405397 PN 6405397 EIA 422A DTE male - male 38 meters (125 feet) * PN 6405398 * Only available in EMEA countries ** Only available in U.S.A. and A/FE countries 11-2 3708 Planning and Installation

1. Cables are shipped separately from the 3708. Allow 2 weeks for delivery.

See "Cable Descriptions" on page 10-1 for more information. 2. MES is the Miscellaneous Equipment Specifications. The following table shows the items that are additional or optional for the 3708. Order Order Order Description Contact System Number Quantity Optional base or power cord (1.8 meters or 6 feet) Marketing Representative AAS 9986 Spare 3708 cartridge without CSC Spare 3708 cartridge with CSC PC/HOST File Transfer and Terminal Emulator Program (See note 1.) Shelves (See note 2.) Rack or table Modems Telephone lines ASCII device manuals (See note 4.) Notes: Marketing MES PN 6405322 Representative PN 6405473 Marketing AAS PN 6476052 Representative OEM (See note 3.) OEM (See note 3.) Marketing AAS Machine type Representative Local telephone company OEM (See note 3.) 1. Refer to Chapter 9, "Planning for File Transfer" for more information. 2. The 3708 requires a shelf to be placed in the rack. 3. OEM is Original Equipment Manufacturer. 4. Refer to Appendix K, "Manuals for Default Protocol Conversion Displays" for more information. Chapter 11. Ordering the 3708 11-3

Installing the 3708

This part provides the following information on installing the 3708: Chapter 12. Installation Procedures Step I. Testing the 3708 Step 2. Setting Up the Control Terminal Step 3. Logging onto the Control Terminal Step 4. Entering the Configuration Data Step 5. Activating the Configuration Step 6. Ending the Control Terminal Session Step 7. Connecting the Cables Chapter 13. Configuration Proccdurco; Defining a Port for a SNA Host Port Number Options (Screen MIOO.I) Port ....... . Port Excluded SN A Host Definition (Screen C 122.1) Host-A Port Host-B Port Port Host Name Host Keyboard Source Field Host Printer Source Field SNA Host Definition (Screen ('122.2) SNA PU Network Name SNA PU Line Network Name Station Address NRZI Data Encoding Permanent RTS (Request to Send) Line Speed Line Type .. . ..... Transmit UNBIND or TERM-SELF for Session Security SDLC Inactivity Time Out Defining a Port for an ASCII Host Port Number Options (Screen M I 00.1 ) Port Port Excluded ASCII Host Definition (Screen CI22.1) Host-A Port Host-B Port Port Host Name Host Keyboard Source Field Host Printer Source Field Set Host Termination Sequence Host Termination Sequence (in ASCII) Line Speed Defining a Port for an End-User Device ... 3708 Port Logon Options (Screen MlOO.2) Port Excluded ..... . Logon Screens Excluded TerminalID 12-1 12-2 12-4 12-5 12-9 12-9 12-10 12-13 13-1 13-2 13-2 13-2 13-3 13-4 13-4 13-4 13-5 13-5 13-5 13-5 13-6 13-6 13-7 13-7 13-8 13-8 13-8 13-8 13-9 13-9 13-10 13-10 13-10 13-11 13-12 13-12 13-12 13-12 13-13 13-13 13·13 13-14 13-14 13-14 13-15 13-15 13-15 13-16 13-19 Installing the 3708

End-User Device Definition (Screen C123.1)

13-20 Port Number ... 13-20 Device Name ....... . . . . . . . . . . 13-20 Device Line Name ............. 13-20 SNA LV Network Name (Keyboard, Host A) 13-21 SNA LU Device Number (Keyboard, Host A) 13-21 SNA LU Network Name (Keyboard, Host B) 13-22 SNA LU Device Number (Keyboard, Host B) 13-22 SNA LV Network Name (Printer on Preassigned Host) 13-23 SNA LU Device Number (Printer on Preassigned Host) 13-23 Default SNA LV Device Number Assignments 13-24 End-User Device Definition (Screen C123.2) 13-25 Password ....... 13-25 Receive XON/XOFF 13-26 Password Retry Limit 13-26 Transmit XON/XOFF 13-27 Line Speed 13-27 Device Class 13-27 Line Type . 13-28 Operating Mode 13-28 Disconnect 13-28 Interface Type 13-29 Translate Option 13-29 Parity ...... 13-30 Receive Queue Size 13-30 3270 Model Emulation 13-31 Receive Queue Pacing Threshold 13-31 End-User Device Definition (Screen C123.3) 13-32 Bits/Character 13-32 Number of Stop Bits 13-33 Inactivity Time Out 13-33 Transmit Data Threshold 13-33 Auto On-Hook 13-33 Transmit Error Threshold 13-33 CDSTL (Connect Data Set To Line) 13-33 Receive Data Threshold 13-34 Send Answertone 13-34 Receive Error Threshold 13-34 Delay after Form Feed . 13-34 Delay after Carriage Return 13-34 Maximum Platen Length . 13-35 What To Do Next ......... 13-35 Protocol Enveloping Definition for an End-User Device (Screen C123.4) 13-36 Full Duplex Line 13-36 Full Duplex Control Unit 13-36 Ignore Parity ....... 13-37 Parity Error Substitution Character 13-37 EchopJex ............... 13-37 Attention Key Substitution Character 13-37 Delay After Receipt of CR 13-37 Recognize Terminal Attention 13-38 Allow Terminal Break 13-38 Delete Rubout Character 13-38 Line Quiet Time ..... 13-38 Recognize System Request Simulation 13-39 Text Time Out .............. 13-39 3708 Planning and Installation

Permanent Request To Send

13-39 Turnaround Characters ... 13-39 Send Read Prompt 13-40 Defining the Printer Authorization Matrix 13-41 Printer Authorization Matrix (Screen CI24.0) 13-41 Printer Port Address 13-41 Printer Mode ... 13-41 Print Class 13-42 Source Device List 13-42 Default Printer Page Length 13-42 Perform Formfeed After Local Copy 13-43 3708 May Transmit Formfeed (LU_l SCS) 13-43 Perform Formfeed at Begin Bracket (LU_I SCS) 13-43 Perform Newline at Begin Bracket (LU_3) 13-43 Chapter 14. Defining the General Definition 14-1 General Definition (Screen C 127.1) 14-1 Name 14-2 Version 14-2 Date 14-2 Time . 14-2 String 1 14-2 String 2 14-2 Non-Standard Operations 14-3 Chapter 15. User-Defined Terminal Tables 15-1 Standard and Enhanced Terminal Tables IS-I Creating a User-Defined Terminal Table IS-2 Looking at the Terminal Table Format IS-3 General Description Section IS-S Terminal ID ....... IS-S Flags . . . . . . IS-6 Cursor Addressing Class lS-8 Alternate Control Sequence Character 15-10 Intermediate Control Sequence Character 15-10 Keyboard Mapping Definition Section IS-II Special Considerations for the Keyboard Mapping Definition Section 15-12 Terminal Control Section .................. 15-13 Special Considerations for the Terminal Control Section 15-14 Customization Section ... IS-16 Changing an Existing Table IS-18 Example 1 ........ 15-18 Example 2 ........ IS-22 Modifying Extended Function Keys IS-26 Using Predefined Terminal Tables . IS-26 Chapter 16. Converting Between Standard and Enhanced UDTs 16-1 Converting Standard to Enhanced 16-3 Converting Enhanced to Standard 16-3 Chapter 17. Creating a User-Defined Translate Table 17-1 Looking at the Translate Table Format 17-1 Defining a New Translate Table ... . . . . . . . 17-2 Installing the 3708

Chapter 12. Installation Procedures

This chapter describes how to install the 3708. Notes: 1. Before installing the 3708 you must complete initial setup of the 3708. Refer to IBM 3708 Network Conversion Unit Setup (shipped with the 3708), complete the initial setup procedures, and then, refer to this book for information on how to configure and install the 3708 into the network. 2. You should complete the Address Registration Form that is shipped with the 3708. 3. Before installing the 3708, it is recommended that you acquire any known microcode fixes (MCFs) for your level of microcode. This can be accomplished by calling the service number (see "Calling for Service" on page 6-3) and requesting that all existing MCFs be installed. Installation consists of the following steps: • Step 1. Testing the 3708 • Step 2. Setting Up the Control Terminal • Step 3. Logging onto the Control Terminal • Step 4. Entering the Configuration Data • Step 5. Activating the Configuration • Step 6. Ending the Control Terminal Session • Step 7. Connecting the Cables. Chapter 12. Installation Procedures 12-1

Step 1. Testing the 3708

This procedure verifies that the 3708 is working correctly before the control terminal and other devices are connected. 1. Press the power switch to off (0) and disconnect any connected cables. 2. Plug the power cord into the back of the 3708, then plug the power cord into an electrical outlet. 12-2 3708 Planning and Installation

3. Press the 3708 cartridge, with the light on the left, firmly into the slot in the

base. Note: After the cartridge is plugged in, do not remove it unless you must do so to solve a problem. 4. Turn on the 3708. The 3708 automatically runs a self-diagnostic test. After approximately 10 seconds, the base Not Ready light and the cartridge light begin blinking alternately. This means that the 3708 is working correctly. (Refer to Chapter 2, "Using Symptoms to Solve a Problem" of IBM 3708 Network Conversion Unit Problem Determination for other light sequence meanings.) = o = Cartridge Light Base Not Ready Light Chapter .12. Installation Procedures 12-3

Step 2 .. Setting Up the Control Terminal

1; Turn off the 3708. 2. Connect the cable from the control terminal to one of the following 3708 ports. Note: The control terminal can be any one of the 3708 default terminals listed in the screen on page 12-6. • Direct connection: use port 7. The terminal must be set for the following: Interface EIA 232C Line Speed 9600 bps Parity Odd Bits per character 7 Stop bits 2 Note: See Chapter 10, "Planning for Cables" for information about the type of cables to use to connect the control terminal. • Remote connection: use port 3. The terminal must be set for the following: Interface Line Speed Parity Bits per character Stop bits Notes: EIA 232C 11 0 - 9600 bps Odd or even 7 2 a. Port 3 is configured for auto baud/auto parity. b. Make sure that the modem settings match the device settings. c. See Chapter 10, "Planning for Cables" for information about the type of cables to use to connect the control terminal. See Appendix I, "Terminal Switch Settings" for the required switch settings for the terminal. You can use other ports besides ports 3 and 7 for the control terminal connection. See Appendix A, "IBM-Supplied Configuration" for the initial port definitions. After configuring the 3708, you can reconfigure all 3708 ports including ports 3 and 7 to connect to any supported device. Note: Make sure that the terminal values for XON/XOFF pacing and line turnaround character agree with the IBM-supplied configuration. 3. Turn on the 3708. 4. Turn on the control terminal. 5. If you are using a modem, establish the connection to the 3708. 12-4 3708 Planning and Installation

Step 3. Logging onto the Control Terminal

1. If the control terminal is remotely connected to port 3, press the carriage return key to start the logon screens. If the control terminal is directly connected to port 7, the logon screens should start when the terminal is turned on. If the logon screens do not start, press the carriage return key. Notes: a. At any time during logon and before the first control terminal screen (MlOO.O) is displayed, you can disconnect the control terminal from the 3708 by typing #### and pressing the carriage return key. b. The 3708 EC number, RID number, and part number may differ from the following examples depending on your microcode level, particular machine, and port. c. During logon, the control terminal operates in protocol enveloping (line-by-line) mode. In this mode, use the period key, carriage return key, or a defined line turnaround character as the ENTER key. You also can use the backspace function if you want to correct typing errors. Other cursor-positioning keys are not operational for logon. The 3708 displays a port password screen as follows: ======IBM 3708===EC A58809======RID 3708-001 88-0000076========PORT 07====== Cl: Type port password To disconnect from the 3708, type n####.n ===> Chapter 12. Installation Procedures 12-5