Text of the manual

24-PORT RACK-MOUNTABLE GIGABIT SWITCH

Model: ASBRM244U1 WARRANTY nexxtsolutions.com/warranty YEAR 3 Ajuste_07_19_2017

Nexxt Solutions - 24 port gigabit switch

Nexxt Solutions - 24 port gigabit switch Copyright Statement Nexxt Solutions™ is a registered trademark. Other trademarks or brand names contained herein are the trademarks or registered brand names of their respective owners. Copyright of the whole product as integration, including its accessories and software, belongs to Nexxt Solutions Ltd. No individual or third party is allowed to copy, plagiarize, reproduce, or translate it into other languages, without express consent from Nexxt Solutions, Ltd. All of the photos and product specifications mentioned in this manual are used as reference only. Upgrades of software and hardware may occur, and should there be any changes, Nexxt Solutions shall not be responsible for notifying about any such modifications in advance. If you would like to know more about our products, please visit our website at www.NexxtSolutions.com. Table of content 1. Introduction 1.1 Switch features 1.2 Package content 1.3 Front and rear panel overview 1.4 LED indicator definitions 2. Installation 2.1 Preliminary steps 2.2 Installation procedures 2.3 Connection of the switch 3. Technical specifications

Nexxt Solutions - 24 port gigabit switch

Nexxt Solutions - 24 port gigabit switch 1. Introduction The Axis is a Gigabit unmanaged Ethernet Switch, specially designed for small to medium businesses that require high performance network connectivity along with advanced internet capabilities. It features UTP/STP RJ-45 ports with auto MDI/MDIX, which can operate at 10/100/1000Mbps. Gigabit ports can also be used as normal or uplink ports to connect a backbone network. Its standard 19-inch rack-mountable case along with its improved transmission rates make it the ideal choice for small and medium sized networks. 1.1 Switch features • Complies with IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE802.3x standards • Supports IEEE802.3x flow control for full-duplex mode, and backpressure flow control for half-duplex mode • Supports auto MDI/MDIX • Supports store-and-forward switching technology • Jumbo frame of 9Kbytes with 48Gbps backplane bandwidth • Advanced loop prevention algorithm • It comes with a 1U steel chassis for standard installation in a 19-inch rack • Integrated lightning protection • Fan-free, energy-saving design 1.2 Package content Upon opening the box, ensure that the following items are included: • 24-port switch • Power cable • Rack-mount bracket kit • Self-adhesive pads (for on-shelf installation) • User guide If any of the listed items are missing or damaged, please contact the reseller who you purchased the switch from for a replacement. 1.3 Front and rear panel overview The front panel features twenty-four 10/100/1000 Mbps UTP ports, with the correspon- ding number of lights to display the activity on each one, plus one indicator light for power. Mode select M1 Network cloning M2 Standard M3 Port trunking M1 Port isolation 24- Port Gigabit Ethernet Switch Axis2400R 23 (Uplink) 24 (Uplink) Front panel 1 3 2 4

Nexxt Solutions - 24 port gigabit switch

Nexxt Solutions - 24 port gigabit switch 1. RJ-45-ports 2. LED status indicators 3. Metal housing 4. Mode selection button On the rear panel, there is the AC power jack with the input range marked. 1. Protective ground screw 2. AC input Note: Please use the supplied power cord only. The use of any other cable may damage the unit and void the warranty. 1.4 LED description LED indicators provide information about the connection and Link/ACT status of the switch. They also facilitate activity monitoring and troubleshooting the performance of the network. The following chart shows the LED indicators of the switch along with an explanation of each indicator. 2. Installation 2.1 Preliminary steps Observe the safety instructions detailed below before connecting the device into your network • Select a location with adequate ventilation all around the unit. • Place the switch on a secure, stable and clean surface. • Allow at least 10cm clearance between the rear panel and the wall to dissipate hot air. • Never place heavy objects on top of the switch. • If you need to stack other devices on top of the switch, a minimum separation of 1.5 cm should be used. • Electrical power supplied should match the voltage specified. 2.2 Installation procedures The switch can be mounted in a rack or placed free-standing on a desktop. 2.2.1 Installation on a flat surface Attach the four self-adhesive rubber pads (supplied) in each corner on the bottom of the chassis Rear panel 100-240V~0.5A-5060Hz Power Receptacle: 100-240V Input LED panel The switch is powered on The switch is either turned off, the connection is loose or there might be a problem with the power cord or outlet The corresponding port is correctly connected The port is actively receiving or transmitting data packets The port is either disconnected or the switch is improperly connected to the remote device Network cloning mode Standard mode Port trunking mode Port isolation mode Solid Off Solid Blinking Off Solid Solid Solid Solid Power Link/Act M1 M2 M3 M4 LED indicator Description Status Mode select M1 Network cloning M2 Standard M3 Port trunking M1 Port isolation 24- Port Gigabit Ethernet Switch Axis2400R 23 (Uplink) 24 (Uplink) Attach the rubber pads to the bottom of the unit 1 2

Nexxt Solutions - 24 port gigabit switch

Nexxt Solutions - 24 port gigabit switch Installing the switch in standard 19-inch rack Rack-mount “L” bracket installation 2.2.2 Installation in a standard 19-inch rack To install the mounting brackets on the switch, follow the steps described below. • First, make sure the rack is properly secured, stable and strong enough to support the weight of the switch. • Attach the two mounting brackets on both sides of the switch using the supplied screws. • Place the unit into the rack, making sure the mounting holes on the device line up with the mounting holes on the rack. • Fasten the chassis in the rack with the screws. 2.3 Connection of the switch 1. Plug the switch into a nearby power outlet with the supplied power cord. 2. Then use ethernet cables to connect the switch to network devices, such as a PC with a NIC port. 3. Switch ports will automatically adjust to the characteristics (MDI-II/MDI-X, speed, duplex) of the device that is connected. The orange Link/Act LEDs for each port will flash when the link is available. Mode select M1 Network cloning M2 Standard M3 Port trunking M1 Port isolation 24- Port Gigabit Ethernet Switch Axis2400R 23 (Uplink) 24 (Uplink) Mode select M1 Network cloning M2 Standard M3 Port trunking M1 Port isolation 24- Port Gigabit Ethernet Switch Axis2400R 23 (Uplink) 24 (Uplink) Mode select M1 Network cloning M2 Standard M3 Port trunking M1 Port isolation 24- Port Gigabit Ethernet Switch Axis2400R 23 (Uplink) 24 (Uplink) Mode select M1 Network cloning M2 Standard M3 Port trunking M1 Port isolation 24- Port Gigabit Ethernet Switch Axis2400R 23 (Uplink) 24 (Uplink)

Nexxt Solutions - 24 port gigabit switch

Nexxt Solutions - 24 port gigabit switch Commonly-used method to access the ethernet With 24 UTP/STP ports available, multiple PCs, printers and other network devices with RJ45 ports can be connected simultaneously to this switch. 3. Operating modes This switch comes equipped with four preconfigured operating modes, selectable through the Mode select button found on the front panel. In order to cycle through modes, press and hold the Mode select button for 4 seconds. LED lights from M1/M2/M3/M4 will all blink once at the same time confirming you are now in the selection mode. Press the button once until obtaining the desired mode. The Mode select M1 Network cloning M2 Standard M3 Port trunking M1 Port isolation 24- Port Gigabit Ethernet Switch Axis2400R 23 (Uplink) 24 (Uplink) RJ45 RJ11 Cable/DSL Modem WAN LAN LAN LAN LAN Router Ethernet PC1 PC2 PC3 Server switch will automatically go out of selection mode after 5 seconds and lock in the selected mode. • M1 Networking clone – Closed flow control on all ports to resolve speed drops in 10/100/1000Mbps mixed networks. • M2 Standard – Open flow control on all ports. Full gigabit switch capabilities in order to be used as a central switch. This is the default setting. • M3 Port trunking – Ports 23 and 24 act as a link aggregation group (static convergence: source MAC + destination MAC). Increases uplink bandwidth and reduces uplink bottlenecks to prevent data congestion. • M4 Port isolation – Ports 1-22 become isolated from each other. Ports 23 and 24 are the convergence of the upper joint. This mode can isolate broadcast storms, prevent ARP and DHCP spoofing, enhance network transmission rate and security. This mode is mainly used for internet cafes, schools, businesses and public networks.

Nexxt Solutions - 24 port gigabit switch

Nexxt Solutions - 24 port gigabit switch 4. Technical specifications IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3x 24 x 10/100/1000Mbps Auto-MDI/MDI-X 10Mbps: 14880pps 100Mbps: 148800pps 1000Mbps: 1488000pps Power and status lights Rackmountable Star 48Gbps 9Kbytes 8000 Automatic update Loop prevention between nodes on the switch, among other connected switches, and loops among downlink devices of the switch Store-and-Forward CSMA/CD IEEE802.3x full duplex and half duplex back pressure 32°F-104°F -40°F -158°F Operating humidity: 10%-90% non-condensing Storage humidity: 5%-90% non-condensing Metal Gun metal 17.3x7x1.7in 4.2lb 100-240VAC Inductive lightning protection: 6kV FCC Three years Standards Ports and interface Forwarding speed LED indicators Format Topological structure Backplane bandwidth Jumbo frame MAC address table MAC address learning Advanced functions Transfer method Access control Flow control Operating temperature Storage temperature Relative humidity Housing Color Dimensions Weight Protection Power input Protection Certificates Warranty Hardware features NW223NXT72 MPN Performance features Software features Environment Physical appearance Additional information FCC statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasona- ble protection against harmful interference in a residential installation. This equipment gene- rates, uses and can radiate radio frequency energy and, if not installed and used in accor- dance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera- tion. The manufacturer is not responsible for any radio or TV interference caused by unau- thorized modifications to this equipment.