Text of the manual

Regin product information

X9017 Option card, EIB • Makes logic, calculation and control functions possible for an EIB network Communication card for EIB and KNX networks, for internal mounting in an EXOflex house etc. • For applications where EP7408, EP8101 or EP8102 are installed • Suitable for controlling lighting etc. over EIB Option X9017 is a plug-in card for serial communication on the EIB bus. This interface has no galvanic isolation from the rest of the internal electronics. The option occupies Port 2 or Port 3 in EXOflex, and Port 3 in other controllers. The maximum cable length is 3 meters. It is important that the cable is placed away from power cables. See the EIB manual for more information. The figure below illustrates the connection of an EIB bus connector, BCU, to EP8101/EP8102. The DTR output on EP8101/EP8102 cannot be controlled from software but is internally connected to +12 V. revision 08 2007

Regin product information

2 The RS232 Port The designations below follow the RS232 standard’s DTE terminology. Connections Pin no Signal Function Direction Port 2 21 TxD2 Transmit data Out 22 RxD2 Receive data In 23 RTS2 Request to send Out 24 CTS2 Clear to send In 25 GND2 Signal Ground 26 SEL2 Select RS232 interface. The RS232 interface is selected via the hardware if you connect the signal SEL2 to GND2. Port 3 27 TxD3 Transmit Data Out 28 RxD3 Receive Data In 29 RTS3 Request To Send Out 30 CTS3 Clear To Send In 31 GND3 Signal Ground 32 SEL3 Select RS232 interface. The RS232 interface is selected via the hardware if you connect the signal SEL3 to GND3. 33 DTR3 Data Terminal Ready Out 34 DSR3 Data Set Ready In 35 DCD3 Data Carrier Detect In 36 RI3 Ring Indication In

Regin product information

3 Connection of EP7408 with the EIB option X9017 on Port 3. Pin no Signal Detailed function Group function 1 +C +24 V DC. Output for analog inputs AI and digital inputs DI. 2 EMI ground This terminal is connected internally to the PIFA’s frame and to internal protective circuits. It should be connected to the ground rail with a separate, heavy gauge. 3 AI1 Analog input 1, type Multisensor 4 AI2 Analog input 2, type Multisensor 5 AI3 Analog input 3, type Multisensor 6 AI4 Analog input 4, type Multisensor 7 AGnd Reference pole for AI1-AI4 8 SCR Connection for screen, AI1-AI4 9 AO1 Analog output 1, type Standard 10 AO2 Analog output 2, type Standard 11 AGnd Reference pole for AO1-AO2 for high-ohm loads. For low-ohm loads, use the 0 V terminal (20) as reference pole. 12 DTR Option X9017 13 Gnd Signal Ground 14 EMI ground This terminal is connected internally to the PIFA’s frame and to internal protective circuits. It should be connected to the ground rail with a separate, heavy gauge. 15 TxD Transmit Data (Out) 16 RxD Receive Data (In) 17 RTS Request To Send (Out) 18 CTS Clear To Send (In) 19 +24 V DC Inputs for +24 V DC power supply 20 0 V Power supply 0 V. The 0 V-connection is normally grounded at the supply source, so as to define the potential to earth reference and to compensate for disturbances and transients from I/O signals. 21 DI1 Digital input 1, type Standard 24 V DC 22 DI2 Digital input 2, type Standard 24 V DC 23 B3 EXOline connection, Port 3 Galvanically insulated from all other circuits. 24 A3 25 N3 The 0 V reference. This should be connected to the screen of the communication cable, which in turn should be grounded at one point at least. 26 E3 27 TxD3 See “The RS232 Port” on page 2. RS232 connection, Port 3 This connection is galvanically insulated from the internal circuits. GND3 is the signal zero. Use screened cable and earth it at one point. 28 RxD3 29 RTS3 30 CTS3 31 GND3 32 SEL3 33 DTR3 34 DSR3 35 DCD3 36 RI3

Regin product information

4 Connection of EP8101 with the EIB option X9017 on Port 3. Pin no Signal Detailed function Group function 1 EMI ground This terminal is connected internally to the PIFA’s frame and to internal protective circuits. It should be connected to the ground rail with a separate, heavy gauge. 2 nc 8 B EXOline connection, Port 2/3 Galvanically insulated from all other circuits. 9 A 10 N The 0 V reference. This should be connected to the screen of the communication cable, which in turn should be grounded at one point at least. 11 E 12 DTR Option X9017 13 Gnd Signal Ground 14 EMI ground This terminal is connected internally to the PIFA’s frame and to internal protective circuits. It should be connected to the ground rail with a separate, heavy gauge. 15 TxD Transmit Data (Out) 16 RxD Receive Data (In) 17 RTS Request To Send (Out) 18 CTS Clear To Send (In) 19 nc 20 nc 27 TxD See “The RS232 Port” on page 2. RS232 connection, Port 2/3 This connection is galvanically insulated from the internal circuits. GND is the signal zero. Use screened cable and earth it at one point. 28 RxD 29 RTS 30 CTS 31 GND 32 SEL 33 DTR3 34 DSR3 35 DCD3 36 RI3

Regin product information

Head Office Sweden Phone: +46 31 720 02 00 Web: www.regin.se Mail: [email protected] Sales Offices France: +33 14 171 46 46 Hong Kong: +852 24 07 02 81 Singapore: +65 67 47 82 33 Germany: +49 30 77 99 40 Product documentation Document Type EH11...41 / EH10...40 / ECX1 Instruction for EXOflex houses and the EXOflex processor ECX1 EXO System Manual 2005 Manual covering the EXO System Connection of EP8102 with the EIB option X9017 on Port 3. Pin no Signal Detailed function Group function 1 EMI ground This terminal is connected internally to the PIFA’s frame and to internal protective circuits. It should be connected to the ground rail with a separate, heavy gauge. 2 +12 V DC +12 V DC output 3 Gnd3 Signal Ground 4 B2 EXOline connection, Port 2 Galvanically insulated from all other circuits. 5 A2 6 N2 The 0 V reference. This should be connected to the screen of the communication cable, which in turn should be grounded at one point at least. 7 E2 8 B3 EXOline connection, Port 3 Galvanically insulated from all other circuits. 9 A3 10 N3 The 0 V reference. This should be connected to the screen of the communication cable, which in turn should be grounded at one point at least. 11 E3 12 DTR Option X9017 13 Gnd Signal Ground 14 EMI ground This terminal is connected internally to the PIFA’s frame and to internal protective circuits. It should be connected to the ground rail with a separate, heavy gauge. 15 TxD Transmit Data (Out) 16 RxD Receive Data (In) 17 RTS Request To Send (Out) 18 CTS Clear To Send (In) 19 +24 V DC Inputs for +24 V DC power supply 20 0 V Power supply 0 V. The 0 V-connection is normally grounded at the supply source, so as to define the potential to earth reference and to compensate for disturbances and transients from I/O signals. 21 TxD2 See “The RS232 Port” on page 2. RS232 connection, Port 2 This connection is galvanically insulated from the internal circuits. GND2 is the signal zero. Use screened cable and earth it at one point. 22 RxD2 23 RTS2 24 CTS2 25 GND2 26 SEL2 27 TxD3 See “The RS232 Port” on page 2. RS232 connection, Port 3 This connection is galvanically insulated from the internal circuits. GND3 is the signal zero. Use screened cable and earth it at one point. 28 RxD3 29 RTS3 30 CTS3 31 GND3 32 SEL3 33 DTR3 34 DSR3 35 DCD3 36 RI3