Keysight ixia BreakingPoint Storm Installation Manual
Read Online
Read the Keysight ixia BreakingPoint Storm Installation Manual online using the built-in PDF viewer.
Text of the manual
© Keysight Technologies 2005–2018
No part of this document may be
reproduced in any form or by any means
(including electronic storage and retrieval
or translation into a foreign language)
without prior agreement and written
consent from Keysight Technologies, Inc.
as governed by United States and
international copyright laws.
Warranty
The material contained in this document
is provided “as is,” and is subject to being
changed, without notice, in future
editions. Further, to the maximum extent
permitted by applicable law, Keysight
disclaims all warranties, either express or
implied, with regard to this manual and
any information contained herein,
including but not limited to the implied
warranties of merchantability and fitness
for a particular purpose. Keysight shall not
be liable for errors or for incidental or
consequential damages in connection
with the furnishing, use, or performance
of this document or of any information
contained herein. Should Keysight and the
user have a separate written agreement
with warranty terms covering the
material in this document that conflict
with these terms, the warranty terms in
the separate agreement shall control.
Technology Licenses
The hardware and/or software described
in this document are furnished under a
license and may be used or copied only in
accordance with the terms of such
license.
U.S. Government Rights
The Software is "commercial computer
software," as defined by Federal
Acquisition Regulation ("FAR") 2.101.
Pursuant to FAR 12.212 and 27.405-3 and
Department of Defense FAR Supplement
("DFARS") 227.7202, the U.S. government
acquires commercial computer software
under the same terms by which the
software is customarily provided to the
public. Accordingly, Keysight provides the
Software to U.S. government customers
under its standard commercial license,
which is embodied in its End User License
Agreement (EULA), a copy of which can
be found at
http://www.keysight.com/find/sweula or
https://support.ixiacom.com/support-
services/warranty-license-agreements.
The license set forth in the EULA
represents the exclusive authority by
which the U.S. government may use,
modify, distribute, or disclose the
Software. The EULA and the license set
forth therein, does not require or permit,
among other things, that Keysight: (1)
Furnish technical information related to
commercial computer software or
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish
to, or otherwise provide, the government
rights in excess of these rights
customarily provided to the public to use,
modify, reproduce, release, perform,
display, or disclose commercial computer
software or commercial computer
software documentation. No additional
government requirements beyond those
set forth in the EULA shall apply, except to
the extent that those terms, rights, or
licenses are explicitly required from all
providers of commercial computer
software pursuant to the FAR and the
DFARS and are set forth specifically in
writing elsewhere in the EULA. Keysight
shall be under no obligation to update,
revise or otherwise modify the Software.
With respect to any technical data as
defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS 227.7102,
the U.S. government acquires no greater
than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as
applicable in any technical data. 52.227-
14 (June 1987) or DFAR 252.227-7015 (b)
(2) (November 1995), as applicable in any
technical data.
Safety Information
A CAUTION notice denotes a hazardous
situation that, if not avoided, could result
in minor or moderate injury.
A WARNING notice denotes a hazardous
situation that, if not avoided, could result
in death or serious injury.
– ii –
26601 West Agoura Road
Calabasas, California 91302
+1 877 367 4942 – Toll-free North America
+1 818 871 1800 – Outside North America
+1.818.871.1805 – Fax
www.ixiacom.com/contact/info
Support
Global Support
+1 818 595 2599
[email protected]
APAC Support
+91 80 4939 6410
[email protected]
EMEA Support
+40 21 301 5699
[email protected]
Greater China Region
+400 898 0598
[email protected]
Hong Kong
+86 10 5732 3932
[email protected]
India Office
+91 80 4939 6410
[email protected]
Japan Head Office
+81 3 5326 1980
[email protected]
Korea Office
+82 2 3461 0095
[email protected]
Singapore Office
+656 494 8910
[email protected]
– iii –
Product Safety Information
v
Chapter 1 About This Guide
1
Chapter 2 Product Overview
3
Chapter 3 Getting Started
11
Chapter 4 Site and Safety Regulations
29
Chapter 5 Installation Guide
33
Chapter 6 System Configuration
39
Chapter 7 Accessing the Control Center
43
Chapter 8 Frequently Asked Questions
45
Appendix A Hardware Specifications
51
Appendix B Safety Instructions
55
INDEX
63
– iv –
Product Safety Information
Before installing the unit, read all product safety instructions contained in this document.
These instructions contain specific safety messages that will alert you to any hazards
associated with the installation and proper operations of the equipment. Failure to follow
those instructions can result in serious injury or death.
– v –
CHAPTER 1 About This Guide
This section explains the purpose, audience, and organization of this guide. It also defines conventions
used to present instructions and information throughout this guide and includes information on how to
get support for issues encountered while you use your BreakingPoint device.
Purpose
The purpose of this guide is to provide safety regulations, site requirements, and installation
instructions for BreakingPoint Storm.
Target Audience
The intended audience is users of all skill levels.
Organization
This guide is organized into the following sections:
l About This Guide
l Product Overview
l Getting Started
l Site and Safety Regulations
l Hardware Installation
l System Configuration
l Accessing the Control Center
l Frequently Asked Questions
l Appendix
l Index
Conventions
This guide uses the conventions listed in the following table:
Convention
Description
Example
Bolded text
Commands, keywords, or
buttons
Press the Enter key.
Courier New
font
User input
Type GET in the Method Request box.
– 1 –
Helpful suggestion or
reference to
additional information
Note: Racks must meet standard EIA-310-C
requirements.
Related Documentation
The following table lists all the documentation related to BreakingPoint Storm. You can access all
documentation through the Documentation area of Strike Center.
Documentation
Description
BreakingPoint Storm
Installation Guide
Provides installation instructions and information for BreakingPoint Storm.
BreakingPoint Storm
User Guide
Provides information on how to use the Control Center to set up,
customize, and run traffic through devices under test.
BreakingPoint Online
Help
Online documentation for all BreakingPoint products. Requires Internet
Explorer 10.0 or Firefox 18.0 for proper viewing.
Strike Center
Strike Center is an online portal for security and firmware updates as well as industry information. You
can use Strike Center to do the following:
l Obtain the latest firmware releases for BreakingPoint Storm.
l Download the most up-to-date ATI Updates (formerly known as StrikePacks), which includes the
latest strikes, test capabilities, and application protocols.
l Download PDFs of documentation.
l Find contact information for customer support, sales, and corporate facilities.
l Access blogs and technical articles related to vulnerabilities, exploits, and recent updates to any
BPS product.
Documentation Feedback
Please send any feedback or suggestions regarding this documentation to
[email protected].
Chapter 1 About This Guide
– 2 –
CHAPTER 2 Product Overview
This section covers the following:
l BreakingPoint Storm Overview
l Hardware Overview
l Control Center Overview
BreakingPoint Storm Overview
BreakingPoint Systems has developed a product that measures and hardens the resiliency of every
component of your critical infrastructure against potentially crippling attacks and peak application
traffic: the BreakingPoint Storm. It is a 4 RU rack-mountable, modular product that can accurately
recreate a live network environment.
BreakingPoint Storm consists of the chassis and the user interface called the Control Center. Both
components work together to create a comprehensive and user-friendly test solution for all network
devices. BreakingPoint Storm can concurrently simulate TCP sessions, application traffic, and live
security attacks, and ultimately, identify 'breaking points' in your network devices.
Hardware Overview
BreakingPoint Storm is comprised of five modules. The following image highlights these modules with
callouts:
Callout 1 refers to the removable fan tray that is vertically mounted on the right-side of the chassis.
– 3 –
Callout 2 and Callout 3 refer to the modules dedicated to high-speed data plane processors, or the
blades, for the computer. When you initially receive BreakingPoint Storm, these modules will not
contain any blades, so you will need to install the blade(s) into the chassis. For more information on
installing the blades, see Installing the Blade.
If you are using 10 Gb blades, you will have four fiber-optic data ports that support up to 10 Gbps. If
you are using 1 Gb blades, you will have eight copper data ports that support up to 1 Gbps. If you are
using 4-Port 1 GigE blades, you will have either four copper or four fiber-optic data ports that support
up to 1 Gbps. The fiber-optic connections and copper connections between the ports on your device
under test to the test ports on the chassis establish the transmitting and receiving interfaces for your
tests. For more information on connecting your device under test to BreakingPoint Storm, see
Connecting a Device Under Test to BreakingPoint Storm.
Depending on the number of blades purchased for BreakingPoint Storm, your chassis may have either
one or two blades. The number of tests that you can run concurrently depends on the number of
available ports that BreakingPoint Storm has. For example, a single-blade BreakingPoint Storm with
four available ports can only run four tests at a time. A two-blade chassis with 16 total available ports
can run 16 tests simultaneously. However, to run all 16 tests concurrently, you will need to assign
each available port to a different Active Group. For more information, see the BreakingPoint Storm User
Guide.
Callout 4 points to the computer controller, which holds the BPS management ports, target control
ports, and reset button. There is an eSATA port as well.
The computer controller will not be installed when you initially receive BreakingPoint Storm. For more
information on installing the computer controller, see Installing the Computer Controller.
The BPS management ports (serial and ethernet), located on the computer controller, allow you to
connect your computer to a network and access it through an IP address. The target control ports allow
you to automate testing for the device under test. The reset button restores your computer to the
default factory settings.
Callout 5 refers to the power tray, which contains the power supply for the computer.
Front-view
The following image illustrates the front of BreakingPoint Storm. Locate the corresponding callout in
the following table for more information about each component.
Chapter 2 Product Overview
– 4 –
Holds the fan tray for the computer.
2
Data Ports
Transmits and receives traffic to and from the DUT.
3
Target
Control
Serial Port
Used to manage and configure settings for the DUT.
4
Target
Control
Ethernet Port
Used to manage and configure settings for the DUT.
5
BPS
Management
Serial Port
Manages the BreakingPoint Storm configuration through a serial
connection.
6
BPS
Management
Ethernet Port
Manages the BreakingPoint Storm configuration through an ethernet
connection.
7
eSATA Port
Provides an eSATA connection for an external memory device.
8
Reset button
Restores the computer to factory settings. This process is irreversible and
all tests, imported data, and configurations are permanently removed from
the computer.
Chapter 2 Product Overview
– 5 –
The power inlet and power switch are located on the back of the chassis, as shown in the following
image. Additionally, there are BNC interfaces that you can use in future releases to link together
multiple chassis. As of the 1.3 Release, you can only use one chassis at time.
Callout
Component
Description
1
BNC
Interfaces
Interfaces that are used to connect multiple chassis together (for clock I/O
and trigger I/O).
2
Power
Switch
Power breaker switch for BreakingPoint Storm.
3
Power Inlet
Power inlet for BreakingPoint Storm.
Control Center Overview
The Control Center is a web-based user interface where you can create the testing environment, run
tests, and view reports. The Control Center is accessible through a Flash-enabled web browser, such as
Internet Explorer, Mozilla Firefox, Safari, and Opera. You must also have JavaScript turned on to view
the Control Center.
Note: Safari 6.0.2 on Mac OS 10.8.2 and Safari for Windows are not supported. Mac users with
OS 10.8.2 can use Firefox or Chrome as their browser.
Note: We recommend that users of Internet Explorer use IE 10. IE 9 and earlier versions are not
supported.
Enabling JavaScript
You must have JavaScript turned on to view the Control Center.
To turn on JavaScript for Internet Explorer, do the following:
Chapter 2 Product Overview
– 6 –
1. Open an Internet Explorer browser window.
2. Click Tools > Internet Options from the menu bar.
3. Click the Security tab.
4. Click Custom Level.
5. Scroll down to the Scripting section.
6. Find the category called Active Scripting.
7. Click Enable for this category.
8. Click Yes when the confirmation window appears.
9. Click OK to close the Internet Options window.
To turn on JavaScript for Mozilla Firefox, do the following:
1. Open a Mozilla Firefox browser window.
2. Click Tools > Options from the menu bar.
3. Click Content located at the top of the window.
4. Click Enable JavaScript.
5. Click OK to close the Options window.
To turn on JavaScript for Safari, do the following:
1. Open a Safari browser window.
2. Click Preferences from the Safari menu.
3. Click Security from the top of the window.
4. Click Enable JavaScript located under the Web Content section.
5. Close the Security window.
Accessing the Control Center
To access the Control Center, you must have a web browser with the following items turned on or
installed:
l Adobe Flash Player (version 11.6.602.171)
l Pop-ups
l JavaScript
Additionally, you must have the host address that has been set for the BPS Management Port and the
Control Center login information.
Note: The chassis must already be installed and configured before the Control Center can be
accessed.
Chapter 2 Product Overview
– 7 –
To access the Control Center, do the following:
1. Open a Web browser.
Note: After upgrading or reverting to any release of the BreakingPoint Firmware, clear
your cache and refresh your browser.
Note: The default address is http://10.10.10.10, however, the host address may have
changed during the initial configuration of the computer. Contact the System Administrator
for the current host address.
2. Type the host address for the BPS Management port in the Address bar.
3. Click Launch BreakingPoint Systems Control Center in the Start page.
Note: The first time you attempt to log on to the computer, your browser will require you
to verify a security exception to login. Follow the steps required by your browser to accept
and verify the security exception. After the security exception has been accepted and
verified, you will be allowed to continue with the login process. A new window opens and
shows the Control Center login page.
4. Type the login ID in the Username box.
5. Type the password in the Password box.
Note: Passwords are case sensitive.
6. Click Login.
Note: The computer allows three invalid logins. If you type invalid login information on
the fourth attempt, the login window will lock you out. Refresh the browser to unlock your
accounts.
Chapter 2 Product Overview
– 8 –
This section provides an overview of the navigational areas in the Control Center. The Control Center is
divided into two main areas: the menu bar and the navigational buttons. See the following image for a
tour of the interface:
Callout
Name
Description
1
Menu Bar
Provides point and click access to the main areas of the user interface.
2
Device
Status
Provides access to the Device Status area so that you can reserve ports
while no tests are running or the Real Time Statistics screen if there is a
running test.
3
Navigational
Buttons
Provides access to areas within the user interface.
Chapter 2 Product Overview
– 9 –
CHAPTER 3 Getting Started
Note: You can also reference the BreakingPoint User Guide for the most current information on
performing the tasks described in this topic.
This section covers the following:
l Getting Started Overview
l Task 1: Installing the BreakingPoint Device
l Task 2: Configuring the BreakingPoint Device
l Task 3: Establishing a BreakingPoint Session
l Task 4: Accessing the BreakingPoint Control Center
l Task 5: Creating a User Account
l Task 6: Setting the Time and Date
l Task 7: Creating a Device Under Test Profile
l Task 8: Creating a Network Neighborhood
l Task 9: Making Port Reservations
l Task 10: Creating a Test
Getting Started Overview
This section provides an overview of the tasks that you must complete to install and configure the
BreakingPoint device, as well as explain how to set up your test environment within the BreakingPoint
Control Center.
The following table lists the Getting Started tasks:
Task
Description
Task 1
Installing the BreakingPoint Device.
Task 2
Configuring the BreakingPoint Device.
Task 3
Establishing a BreakingPoint Session.
Task 4
Accessing the BreakingPoint Control Center.
Task 5
Creating user accounts.
– 11 –
Setting the time and date.
Task 7
Creating a DUT Profile.
Task 8
Creating a Network Neighborhood.
Task 9
Making Port Reservations.
Task 10
Creating a test.
Task 1: Installing the BreakingPoint Device
This section describes how to set up the BreakingPoint device.
To set up the BreakingPoint device, do the following:
1. Secure the chassis into an equipment rack.
Note: The chassis must be close enough to the device under test so that you can connect
cables from the appliance to the device under test.
2. Insert the computer controller into the module over the power tray.
3. Insert the blade(s) into the top two modules.
4. Power the computer.
5. Connect the device under test to the BreakingPoint device.
Task 2: Configuring the BreakingPoint Device
You will need to use either a telnet client or text console to configure the network settings for the
BreakingPoint device. The following sections provide instructions for configuration through a telnet
client or a text console.
Telnet
This section describes how to configure the host address, netmask, and gateway for the BreakingPoint
device by using either a telnet client or a text console.
Chapter 3 Getting Started
– 12 –
To configure the BreakingPoint device by using Telnet, do the following:
1. Open a telnet client (for example, PuTTy or AlphaCom).
2. Telnet to the following host address: 10.10.10.10.
3. Specify your terminal emulation preference (for example, ANSI or xterm) at the prompt and press
Enter.
4. Specify the following information for your BreakingPoint device in the Network Information box:
l DHCP Enable/Disable
Note: If DHCP is turned off, you can configure additional computer routes from the
Routes tab in the Administration area of the Control Center. If DHCP is turned on,
the Routes area will be unavailable.
l DHCP Hostname
l IP Address
l Netmask
l Gateway
5. Click Next.
6. Type the login ID for the user account at the prompt.
Note: The login ID must use alphanumeric characters and consist of 1-15 characters. The
first character of the login ID must be a letter. Login IDs cannot solely consist of numbers.
The login ID cannot be changed after it has been created.
7. Type the password for the user account at the prompt.
Note: The password can consist of up to 15 alphanumeric and special characters.
The computer disconnects while the new network settings are applied and your account is created.
Document the network IP address and user account information. You will need this information to
access and log on to the BreakingPoint Control Center. You may create additional accounts through the
Administration page in the BreakingPoint Control Center.
Text Console
This section describes how to configure the host address, netmask, and gateway for the BreakingPoint
device by using a text console.
To configure the BreakingPoint device by using a text console, do the following:
1. Open a terminal emulation client (for example, HyperTerminal).
2. Connect to the BPS management serial port by using the following settings:
l Baud Rate: 115200 bps
l Data Bits: 8
l Parity: None
l Stop Bits: 1
l Flow Control: None
Chapter 3 Getting Started
– 13 –
3. Specify the following information in the Network Information box:
l DHCP Enable/Disable
l DHCP Hostname
l IP Address
l Netmask
l Gateway
4. Click Next when you are done inputting your network settings.
5. Type the login ID that you want to use for the user account at the prompt.
6. Type the password for the user account at the prompt.
The computer disconnects while the new network settings are applied and your new account is created.
Document the network IP address and user account information. You will need this information to
access and log on to the BreakingPoint Control Center. You may create additional accounts through the
Administration page in the Ixia web app.
Task 3: Establishing a BreakingPoint Session
The Breaking Point (BPS) application has been integrated into Ixia’s web app. This integration enables
you to access the BreakingPoint Control Center from the Ixia web app user interface. You can also
configure certain BreakingPoint chassis properties through the Ixia web app user interface. You can
now create new user accounts and manage them through the Ixia web app user interface.
To establish a BreakingPoint session and operate in the BreakingPoint Control Center, you must first
log on to the Ixia web app.
Note: A session is an individual instance of a running test. You can run multiple sessions at one
time, and manage all your current sessions from a single window. You manage sessions on the
Sessions page, which appears after you log on.
To establish a BreakingPoint session, do the following:
1. Open a web browser.
2. In the URL box, type the IP address or hostname of the Ixia chassis where the Ixia web app
server components are installed, followed by the port number that the Ixia web app server is
listening on (the default is 8080), and then press Enter.
Example: 192.168.100.56:8080
The Login page appears.
3. In the Username box, type your user ID.
4. In the Password box, type your password.
5. If you want the browser to automatically fill in the Username and Password field for future logins,
select the Remember Me check box.
6. Click Login. The Sessions page appears.
7. Click the BreakingPoint New Session icon. The BreakingPoint Control Center appears.
Chapter 3 Getting Started
– 14 –
Task 4: Accessing the BreakingPoint Control Center
The BreakingPoint Control Center is a web-based user interface where you can create the testing
environment, run tests, and view reports. The BreakingPoint Control Center is accessible through an
Adobe Flash-enabled web browser, such as Internet Explorer, Mozilla Firefox, Safari, and Opera. You
must also have JavaScript turned on to view the BreakingPoint Control Center.
Note: Safari 6.0.2 on Mac OS 10.8.2 and Safari for Windows are not supported. Mac users with
OS 10.8.2 can use Firefox or Chrome as their browser.
Note: We recommend users of Internet Explorer to use IE 10. IE 9 and earlier versions are not
supported.
Viewing the BreakingPoint Control Center requires a web browser with the following items either turned
on or installed:
l Adobe Flash Player (version 11.6.602.171)
l Pop-ups
l JavaScript
Enabling JavaScript
You must have JavaScript turned on to view the BreakingPoint Control Center.
To turn on JavaScript for Internet Explorer, do the following:
1. Open an Internet Explorer browser window.
2. Click Tools > Internet Options from the BreakingPoint Control Center menu bar.
3. Click the Security tab.
4. Click Custom Level.
5. Scroll down to the Scripting section.
6. Find the category called Active Scripting.
7. Click Enable for this category.
8. Click Yes when the confirmation window appears.
9. Click OK to close the Internet Options window.
To turn on JavaScript for Mozilla Firefox, do the following:
1. Open a Mozilla Firefox browser window.
2. Click Tools > Options from the BreakingPoint Control Center menu bar.
3. Click Content located at the top of the window.
4. Click Enable JavaScript.
5. Click OK to close the Options window.
To turn on JavaScript for Mozilla Firefox 23, do the following:
1. In the address bar, type about:config and press Enter.
2. Click "I'll be careful, I promise".
Chapter 3 Getting Started
– 15 –
3. In the search bar, search for javascript.enabled.
4. Right click the result named javascript.enabled and click Toggle. JavaScript is now turned off.
To turn on JavaScript, repeat these steps.
To turn on JavaScript for Safari, do the following:
1. Open a Safari browser window.
2. Click Preferences from the Safari menu.
3. Click Security from the top of the window.
4. Click Enable JavaScript located under the Web Content section.
5. Close the Security window.
You must also have the host address that has been set for the BPS management port and the
BreakingPoint Control Center login information.
Note: The chassis must already be installed and configured before the BreakingPoint Control
Center can be accessed. For more information on installing and configuring your BreakingPoint
device, see your BreakingPoint device’s installation guide.
Browser Resources
If you have several browser windows open simultaneously, or if you have multiple instances of the
BreakingPoint Control Center open, this may cause lagging or delayed responses from the computer.
This is normal behavior for the BreakingPoint Control Center if multiple browser resources are being
used.
Note: We recommend clearing your cache and refreshing your browser after upgrading or
reverting to any release of BreakingPoint.
Navigational Overview
This section provides an overview of the navigational areas in the BreakingPoint Control Center. The
BreakingPoint Control Center is divided into two main areas: the BreakingPoint Control Center menu
bar and the navigational buttons. See the following image for a tour of the interface:
Chapter 3 Getting Started
– 16 –
The following table lists the elements of the BreakingPoint Control Center:
Callout
Name
Description
1
Menu Bar
Provides point and click access to the main areas of the user interface.
2
Device
Status Icon
Provides access to the Device Status area so that you can reserve ports
while no tests are running or the Real-Time Statistics screen if there is a
running test.
3
Navigational
Buttons
Provides access to areas within the user interface.
4
Firmware
Version
Information
Provides firmware version and update information.
Task 5: Creating a User Account
Only admin users can create user accounts or edit all the properties of a user account. If you are a non-
admin user, the only change you can make to your own account is to change your password.
To create or edit a user account, do the following:
Chapter 3 Getting Started
– 17 –
1. Log on with an admin account.
2. Click Administration > Users.
3. Click New User. The Create User Account window appears.
4. Configure the account. (See the following table for fields and parameter descriptions.)
5. Click OK to create the account.
The following table lists and describes the parameters of the Edit Account window:
Parameter
Description
Username
Name for the account.
Create
Password/Confirm
Password
Password for the user name.
Full Name
Name identifying the user.
Email
Email for the user account. If this user chooses to receive test results by email,
this is the email address that will be used.
Assigned to
Groups
Group that the user account will belong to:
l Admin: Administrators have authority over all user accounts.
l Regular Users: Standard users can change some aspects of their accounts
and run the applications that administrators have authorized for them.
Permissions to
Use
Applications that this user account will be allowed to run.
Task 6: Setting the Time and Date
To set the computer time and day, go to the System Settings tab of the Ixia Administration page.
The controls on this window set the time and date on the chassis. The computer time and date appears
in test results and system logs. The time and date are not set by default. You need to set it when you
install a new chassis.
Note: The time and date do not automatically adjust for Daylight Savings Time. You must
manually change the time to account for Daylight Savings Time.
To set the time and date, do the following:
1. Log on with an admin account.
2. Click Administration > System Settings.
3. Click System time and date.
4. Configure the time and date. (See the following table for parameters and descriptions.)
5. Click Apply to set the time and date.
The following table lists and describes the parameters of the System time and date window:
Chapter 3 Getting Started
– 18 –
Current time (hours:minutes) in 24-hour clock format.
Date
Today's date.
Time zone
Time zone where the chassis is located.
Task 7: Creating a Device Under Test Profile
This section describes how to create a DUT profile. A DUT profile defines the connection settings for the
device under test, such as the device’s connection type, connection parameters, link type, and global
commands. The BreakingPoint device uses these settings to connect to the device under test for
remote scripting. For more information on DUT Profiles, see the DUT Profiles section in the user guide.
Note: The BreakingPoint device provides a default DUT profile called BreakingPoint Default.
This DUT profile cannot be modified or deleted, however, it can be cloned and customized for
your device.
To create a DUT profile, do the following:
1. Click Control Center > Device Under Test from the BreakingPoint Control Center menu bar.
2. Select a profile from the Profile Name list to clone.
3. Click Clone the selected DUT.
4. Type a name for the DUT profile in the Name field and click OK.
Chapter 3 Getting Started
– 19 –
5. Click Device Selection and select a device type (optional).
Note: Each device type has its own set of global commands. Select the device type that
best fits your device.
6. Click Connection Type and select Telnet, SNMP, SSH, or Serial.
Note: If you select Serial, the DUT must be plugged into the chassis through the BPS
management serial port. If you select Telnet or SSH, the DUT must be plugged into the
chassis through the BPS management ethernet port.
7. Define the connection parameters for the DUT under the Connections Settings area. For more
information on connection parameters, see the Connection Parameters section in the user guide
for a list of valid parameter values.
8. Enable or disable any global commands from the Global Commands list.
Note: All cloned DUT profiles inherit the active global commands from its parent DUT
profile. For more information on commands, see the Commands section in the user guide.
9. Click Apply.
Task 8: Creating a Network Neighborhood
A Network Neighborhood consists of all the domains for each test interface. The domains consist of
subnets, which set the range of source and destination addresses for the test traffic sent or received by
the interface. For each test component, specify the domain that the component uses to obtain the
source and destination addressing for its traffic.
Each domain consists of a single subnet, or it can have multiple subnets depending on whether or not
the domain supports VLANs. All VLAN-enabled domains have more than one subnet. Any other type of
domain can only have one.
Note: The computer randomly selects VLAN IDs from the Network Neighborhood. Therefore,
some VLAN IDs may be used multiple times, whereas others may not be used at all.
This task is broken into four parts:
1. Creating a Network Neighborhood.
2. Adding a domain to the Network Neighborhood.
3. Defining the subnet for the domain.
4. Adding additional interfaces to the Network Neighborhood (for two-blade chassis).
Creating a Network Neighborhood
This section describes how to create a Network Neighborhood.
Chapter 3 Getting Started
– 20 –
To create a Network Neighborhood, do the following:
1. Click Control Center > Network Neighborhood from the BreakingPoint Control Center menu
bar.
2. Click Create a new network neighborhood (‘+’) located under the Network Neighborhoods
list.
3. Type a name for the Network Neighborhood in the Name box.
4. Click OK.
Note: Each interface has a default domain with a reconfigured subnet.
Defining a Subnet
This section describes how to add a subnet to a non-VLAN tagging subnet on a non-external interface.
For information on external device addressing or VLAN-enabled addressing, see the External Interface
Addressing or Defining a VLAN-Enabled Subnet section in the user guide.
Chapter 3 Getting Started
– 21 –
To define a non-VLAN subnet, do the following:
1. Click Control Center > Network Neighborhood from the BreakingPoint Control Center menu
bar.
2. Select a Network Neighborhood from the Network Neighborhoods list.
3. Select a test interface to modify by clicking the Interface tab.
4. Select a domain from the Domains list.
5. Click Show the create new subnet form (‘+’) located under the Subnets list. The Create
new subnet dialog box appears.
Note: If you are adding a subnet to an empty domain, you can skip this step. The Subnet
form will already be blank and ready for you to input addressing information.
6. Select IPv4 or IPv6 addressing.
7. Click VLAN Tagging and select a VLAN tag.
8. Select Use NAT for network address translation (if applicable).
9. Type an IP address in the Network IP Address box. To assign an IPv4 address, use the format
x.x.x.x, where x is a number between 0-255. To assign an IPv6 address, use the format x:x:x:x,
where x is a valid hexadecimal value.
10. Type a mask for the network address in the Netmask box. For IPv6 addressing, type the prefix in
the Prefix field.
11. Type a gateway address in the Gateway IP Address box. To assign an IPv4 address, use the
format x.x.x.x, where x is a number between 0-255. To assign an IPv6 address, use the format
x:x:x:x, where x is a valid hexadecimal value.
Chapter 3 Getting Started
– 22 –
12. Click Type.
13. Do one of the following:
l Click Host from the Type list to use one MAC address per host.
l Click Virtual Router from the Type list to use one MAC address for all hosts, and type an
IP address for the virtual router in the Router IP Address box.
Note: If an IPv6 router is present, the BreakingPoint device generates at least one global
address. You can discover the automatically generated IPv6 address through the
SSH/telnet/serial interface, by using the networkInfo command.
14. Type an ethernet address in the Ethernet Address box. Use the format xx:xx:xx:xx, where x is
a valid hexadecimal value.
15. Turn on or turn off the Use Address Range option.
16. Type a range of IP addresses by using the Minimum IP Address and Maximum IP Address
box. Use the format x.x.x.x, where x is a number between 0-255.
Note: If Use Address Range is turned off, you only need to type an IP address in the
Minimum IP Address box. The system only uses one IP address for the entire subnet.
17. Click Add Subnet.
18. Click Save Network.
Adding a Test Interface
By default, the computer provides you with four transmitting and receiving interfaces and one external
interface (for SSL testing). So, if you have a two blade chassis, you will need to add additional
interfaces to your Network Neighborhood.
Each test interface in the Network Neighborhood corresponds to a data port on the chassis. When you
add an interface to a Network Neigbhorhood, the computer automatically numbers the interface based
on the order in which it was added.
If you delete any of the interfaces, the computer automatically sequences the interfaces again. The
succeeding interfaces (following the deleted interface) will be renumbered to the preceding interface’s
value (for example, ‘6’ will become ‘5’).
Note: There can be up to eight test interfaces in a Network Neighborhood and one external
interface.
To add a test interface to a Network Neighborhood, do the following:
1. Click Control Center > Network Neighborhood from the BreakingPoint Control Center menu
bar.
2. Select a Network Neighborhood from the Network Neighborhoods list.
3. Click Add New Interface (‘+’).
Note: The interface contains one domain with the default subnet.
After you have added the interface to the Network Neighborhood, add subnets in the usual way. For
more information on defining subnets, see Defining a Subnet.
Chapter 3 Getting Started
– 23 –
Task 9: Making Port Reservations
The number of tests that you can run concurrently depends on the number of available ports that the
BreakingPoint device has. For example, a single-blade BreakingPoint device with four available ports
can only run four tests at a time. A two-blade chassis with sixteen total available ports can run sixteen
tests simultaneously. To run all sixteen tests concurrently, however, you will need to assign each
available port to a different Active Group.
To run tests on the BreakingPoint device, you must make port reservations. A port reservation occurs
when you click a port to reserve it under your account. No other users can run tests or system
processes on that port while it is reserved under your account.
When you click a port to reserve it, the computer will lock the port reservation under your account.
Locking a port reservation also reserves all other ports under your account as well, however, only the
ports with locked reservations can be used to run tests.
Note: To run two tests concurrently, each set of blades must be assigned to a different Active
Group. For more information on Active Groups, see the Active Groups section in the user guide.
There are three ways to reserve a blade:
l Reserving an unreserved blade.
l Force reserving a reserved blade.
l Simultaneously reserving or unreserving a blade.
Reserving an Unreserved Blade
Unreserved blades may be reserved simply by selecting the Active Group to which you would like to
assign the blade, and then clicking the port that you would like to reserve. This locks the port
reservation, as well as reserves all the ports on the blade under your account.
Note: A lock containing the Active Group appears on all the ports on the blade.
When reserving your ports, remember the order in which you reserve them. Whenever you reserve a
port, the computer automatically maps that port to an interface on the chassis. For example, if you
reserve ports 0 and 1, port 0 will map to interface 1 and port 1 will map to interface 2. You can use
these interfaces to run tests. If an interface is not mapped to a port, you cannot use that interface to
run tests.
If you want to remap the ports to different interfaces, click Port Mapping, located on the Device
Options screen, and manually remap the ports.
Note: You can map only reserved ports to interfaces.
To reserve ports on an unreserved blade, do the following:
1. Click Control Center > Device Status from the BreakingPoint Control Center menu bar.
2. Click Active Group.
3. Select the Active Group to which you would like to assign the ports.
4. Click the port(s) that you would like to reserve.
Chapter 3 Getting Started
– 24 –
Note: A lock appears over the reserved port. All other ports are tagged with a small blue icon,
denoting the port’s Active Group. These ports, even though they have not been manually
reserved by you, are reserved under your account.
Force Reserving a Blade
If another user has reserved the ports on a blade, you can force reserve all the ports on that blade by
clicking any of the ports. During a force reserve, the computer alerts you that the ports are reserved by
another user and asks if you want to force reserve all the ports on that blade. If you force reserve the
port at this point, the computer reserves all the ports on that blade under your account.
Note: You cannot force reserve ports if there is a test or computer process running on any of the
ports on the blade. This computer alerts you that there is a process running on that module.
You should check the port notes before you force reserve the port(s) because other system users may
not want you to remove their port reservations. If available, the port notes will appear as a yellow note
icon located next to the port.
As a best practice recommendation, you should add a port note to your reserved ports. For example,
you may want to note that you will be running tests on these ports everyday between 14:00 and 16:00.
This may prevent other users from removing your port reservations.
To force-reserve ports, do the following:
1. Click Control Center > Device Status from the BreakingPoint Control Center menu bar.
2. Click the port(s) that you would like to reserve.
Note: You can only force reserve ports that do not have tests or computer processes
running on them.
3. Click Yes when the dialog window appears, asking if you would like to force reserve all the ports
in the module.
Note: The port(s) that you clicked will show a locked icon, denoting that this port has
been reserved by you. All other ports are tagged with a blue note icon, showing the active
group to which the ports belong.
Simultaneously Reserving or Unreserving All Ports On A Blade
When you right-click a port, you can conveniently reserve or unreserve all ports on that slot without
having to individually select them.
To simultaneously reserve or unreserve all ports on a blade, do the following:
1. Click Control Center > Device Status from the BreakingPoint Control Center menu bar.
2. Click the Active Group that you would like to use from the list.
3. Right-click the slot that has the ports, which you would like to reserve or unreserve.
4. Click Reserve/Unreserve all ports on this slot.
Chapter 3 Getting Started
– 25 –
Task 10: Creating a Test
This section describes how to create a test from start to finish, which includes selecting the Network
Neighborhood and DUT profile, adding a test component, configuring the test component, and running
the test.
To create a test, do the following:
1. Click Test > New Test from the BreakingPoint Control Center menu bar.
2. Click Select the DUT/Network from the Test Quick Steps menu.
3. Select a DUT profile from the Device Under Test(s) list.
Note: Click Open device under test screen to modify the DUT profile. After you have
made your changes, click Return to go back to the DUT and Network Neighborhood
selection screen. For more information on DUT profiles, see Task 7: Creating a Device
Under Test Profile.
4. Select a Network Neighborhood from the Network Neighborhood(s) list.
Note: Click Open network neighborhood screen to modify the Network
Neighborhood. After you have made your changes, click Return to go back to the DUT
and Network Neighborhood selection screen. For more information on Network
Neighborhoods, see Task 8: Creating a Network Neighborhood.
5. Click Accept after you have made selections for the DUT profile and Network Neighborhood.
6. Click Add a test component from the Test Quick Steps menu.
Chapter 3 Getting Started
– 26 –
7. Select the test component that you want to add to the test.
8. Do any of the following:
l Click the Information tab.
n Type a new name for the test component in the Name box (optional).
n Type a new description for the test component in the Description box (optional).
n Select or clear the Active check box (optional).
n Select or clear the Include in Report check box (optional).
n Click Apply Changes when done.
l Click the Interfaces tab.
n Select the interface(s) that will act as the client. The interface(s) that you select must be
mapped to a port.
n Select the interface(s) that will act as the server. The interface(s) that you select must be
mapped to a port.
n Click Apply Changes when done.
l Click the Presets tab.
n Select a Component Preset.
n Click Apply Changes when done.
l Click the Parameters tab.
n Adjust any parameters for the test component.
n Edit the Evasion Profile settings (optional, for the security component only).
n Click Apply Changes when done.
9. Repeat the preceding three steps for each test component that you want to add to the test.
10. Click Define Test Criteria from the Test Quick Steps menu and create the pass and fail criteria
for the test. For more information on pass and fail criteria, see the Test Pass/Fail Criteria section
in the user guide.
11. Click Save As.
12. Type a name for the test in the Name box.
13. Click Save and Run from the Test Quick Steps menu to run the test.
Chapter 3 Getting Started
– 27 –
CHAPTER 4 Site and Safety Regulations
This section covers the following:
l Site Requirements
l Safety Recommendations
l Safety Regulations
Site Requirements
Site requirements must be met before any type of electrical equipment can be installed at your
location. Site requirements include the following:
l Rack Requirements
l Ventilation Requirements
l Environmental Requirements
l Power Requirements
l System Grounding Requirements
l Fiber-Optic Connection Requirements
Review the following site requirements before proceeding with the installation and configuration of
BreakingPoint Storm.
Rack Requirements
BreakingPoint Storm should be installed in a standard 19 inch EIA rack cabinet. We do not recommend
use of an equipment rack with side panels installed because of the horizontal airflow requirements of
BreakingPoint Storm.
If the weight of the equipment on the rack is not evenly distributed, there is a chance that the rack
may tip over. Therefore, the rack needs to be properly anchored to an unmovable support system to
prevent it from tipping over.
Load the rack from the bottom up, filling the lower racks with the heaviest components and the higher
racks with the lightest components. This stabilizes the rack by evenly distributing the weight of the
equipment on the rack.
The vertical spacing on the rack rails must meet the standard EIA-310C spacing requirements of 1 inch
(2.54 cm). For more information on EIA-310C regulations, see Safety Regulations.
– 29 –
BreakingPoint Storm contains a removable fan tray that pulls in cool air from the right side of the
chassis and exhausts hot air on the left. There must be at least three inches of clearance at all of the
ventilation openings to ensure that the chassis is properly ventilated.
Note: BreakingPoint Storm will not power up without the fan tray installed. If one or more fans
on the fan tray fail to operate at full speed, the computer will shut down and the fan tray must be
replaced. If this occurs, contact BreakingPoint Support for further assistance.
Environmental Requirements
BreakingPoint Storm must operate under the following environmental requirements:
l Operating environment: 15°C to 40°C (59°F to 104°F)
l Non-operating environment: -20°C to 70°C (-4°F to 158°F)
l Relative Humidity: 5 to 95%, non-condensing
l Altitude: No degradation up to 13,000 feet above sea level
Power Requirements
BreakingPoint Storm’s power requirements are 100-240 VAC, 4.5 A and 50/60 Hz. The maximum power
consumption is 1,200 W.
System Grounding Requirements
Electrostatic Discharge (ESD) can occur if electronic components are improperly handled. ESD can
cause intermittent or complete computer failure.
To prevent ESD from occurring, you should eliminate static generators (for example, plastic) and static
conductors (for example, metal) from all areas that house electronic equipment or highly charged
materials.
Note: Use proper ESD protection whenever handling any parts of BreakingPoint Storm.
Fiber-Optic Connection Requirements
The XFP optical transceivers and fiber-optic connections are classified as Class 1 lasers. This means
that exposure to the laser will not cause eye injury and are generally considered safe, however, we
recommend that you do not look directly into the connectors.
The XFP optical transceivers from the Accessories Kit come with protective dust covers. You should
install the protective dust covers over the transceivers to protect the optical data ports whenever they
are not in use. If you remove the dust covers later on, ensure to properly store them so that you can
easily find them again.
Note: Do not remove the XFP optical transceivers from the data ports. When these ports are not
in use, keep the protective dust covers in them.
Chapter 4 Site and Safety Regulations
– 30 –
This section covers the safety recommendations that you must read before installing or operating
BreakingPoint Storm. Keep in mind that any electronic equipment, like the chassis, can create a
dangerous environment for employees and surrounding equipment if it is installed improperly.
By following the safety recommendations outlined in this section, you can reduce the likelihood of
accidents and ensure the proper installation of BreakingPoint Storm.
Our recommended safety instructions for handling, operating, and maintaining BreakingPoint Storm are
listed as follows:
l Keep the area around the chassis clear and dust-free during and after the installation.
l Only trained and qualified personnel should handle or service BreakingPoint Storm.
l Wear safety glasses when working under any conditions that may be considered hazardous to
your eyes.
l Use proper electrostatic discharge (ESD) protection when handling the blades or the chassis.
l Only trained and qualified personnel, who have thoroughly reviewed the BreakingPoint Storm
Installation Guide, should install, perform maintenance, or request service for the chassis.
l Do not touch uninsulated wires or terminals unless all cables and connections have been
disconnected from the chassis.
l Do not remove the fan tray while BreakingPoint Storm is powered on. Power the computer off and
wait until the fans have stopped running before removing the fan tray from the computer.
l The chassis should be installed at least two feet above the ground.
Safety Regulations
The following table lists the safety regulations to which BreakingPoint Storm is compliant:
Regulation
Description
CE Mark
Certification
The CE mark certification indicates that a product meets the European Union’s (EU)
health, safety, and environmental requirements.
FCC Rules:
Part 15, Class
A
Part 15 of the FCC Rules stipulates that devices must not cause harmful interference
to any radio services, and it describes the technical specifications and
administration requirements for Part 15 devices. For more information on Part 15 of
the FCC Rules, visit the FCC’s website.
EIA-310-C
Requirements
These requirements define the industry specifications for standard 19-inch
equipment racks. The height is measured in units and each unit (U) on the rack is
1.75 inches.
UL-60950-1
This regulation describes the safety standards for low voltage information
technology equipment. This standard specifies requirements intended to reduce
risks of fire, electric shock, or injury to the operator or layman who may come into
contact with the equipment.
Chapter 4 Site and Safety Regulations
– 31 –
CHAPTER 5 Installation Guide
This section covers the following:
l Shipping Package Contents Overview
l Installation Overview
l Powering the Computer
Shipping Package Contents Overview
The shipping packages for BreakingPoint Storm contains the following items:
l BreakingPoint Storm Chassis Kit
n 1 – Fan tray
n 1 – Power tray
n 1 – AC input cable
n 4 – 10-32 x .75 pan screws
l System Controller Kit
n 2 – DB9M-DB9F serial cables
n 2 – CAT6 ethernet cables
n 1 – system controller
l 10 or 1 Gb Blade Kit(s)
n 4 – 10 Gb fiber-optical cable or 8 – ethernet cables
n 4 – XFP optical transceivers (10 Gb Blade Kit only)
n 1 – 10 or 1 Gb blade
Installation Overview
There are three parts to installing the chassis:
1. Mounting the chassis into an equipment rack.
2. Installing the system controller into the chassis.
3. Installing the blade(s) in the chassis.
Before you can install the system controller or the blade(s) into the chassis, we recommend that you
mount the chassis into an equipment rack first.
After you have mounted the chassis into a rack, you can install the blade(s) and the system controller.
There is no particular order in which you need to install the system controller or blade(s), however,
there are designated modules on the chassis that are either dedicated to the system controller or
blade.
– 33 –
The following image shows that the blades are installed in the top two modules, and the computer
controller is installed in the module above the power tray.
Mounting BreakingPoint Storm into an Equipment Rack
The following instructions describe how to mount BreakingPoint Storm into a standard 19-inch
equipment rack. If you require additional information for any other type of rack, see your rack vendor’s
documentation.
A rack unit (RU) is an industry-standard measurement for rack-mountable equipment. Each rack unit is
equal to 1.75 inches and is comprised of three mounting holes. If you look at the rack’s mounting rails,
you will notice small markers that indicate each rack unit. For BreakingPoint Storm, you will need 4 RU
of rackspace.
Typically, you will need to count mounting holes upward, from the first mounting hole in the range of
rack units needed to install the chassis.
Note: For safety purposes, we recommend that you mount BreakingPoint Storm into an
equipment rack before installing the computer controller or blade(s). Additionally, to avoid
injury or damaging the chassis, we recommend you to use three people to mount the chassis.
Guidelines to Keep in Mind
Before you mount the chassis to the equipment rack, ensure that the operating environment meets the
criteria listed in the Site and Safety Regulations section.
Generally, this includes the following:
l Mounting the chassis in an area where air can properly circulate (at least three inches of
clearance around all ventilation openings).
l Ensuring that the chassis has at least three feet of clearance in the rear so you can easily access
the computer’s power switch and inlet.
l Engaging the rack’s stabilizers to keep it stable before mounting the chassis to the rack.
l Placing the chassis in a dry and dust-free area.
Chapter 5 Installation Guide
– 34 –
l Loading the equipment rack from the bottom up.
l Ensuring that the operating environment is 15°C to 40°C (59°F to 104°F)
Required Tools and Mounting Steps
To mount BreakingPoint Storm, you will need the following tools:
l Phillips screwdriver
Use the following instructions to mount BreakingPoint Storm to the 19-inch equipment rack from the
front. This process requires at least three people.
To install BreakingPoint Storm to a 19-inch equipment rack, do the following:
1. Using two people, one on each side of the chassis, lift the chassis.
Note: With one hand, hold the bottom of the chassis, with the other, hold the back of the
chassis for complete support of the computer.
2. Raise the chassis to the desired height in the equipment rack.
Note: The chassis should be placed at least three feet above the ground to prevent dust
particles from collecting inside the chassis.
3. Insert the chassis between the rack rails.
4. Align the four mounting holes on the chassis to the four mounting holes on the equipment rack.
5. Secure the unit by using the 10-32 x .75 supplied rack screws through the holes on the chassis
and into the mounting rails on the equipment rack.
Chapter 5 Installation Guide
– 35 –
Note: This step must be done by the third person, while the two other people are holding
the chassis.
Installing the System Controller
Install the computer controller in the module above the power tray.
To install the computer controller, do the following:
1. Locate the card guide rails.
2. Place the computer controller onto the card guide rails.
3. Slide the card slowly into the module until the front panel of the computer controller is about 1
inch from the chassis.
Note: You may experience some resistance when you slide the system controller into
place, however, this is normal behavior.
4. Verify that the ejectors and thumb fasteners are aligned with the inner mounting rails on
BreakingPoint Storm.
5. Push the computer controller into place after you have verified that the ejectors and thumb
fasteners are properly aligned.
6. Push the ejectors so that they lock the computer controller into place.
7. Tighten the thumb fasteners by turning them in a clockwise direction.
Installing the Blade
Install the blade(s) in the top two modules. If you only have a one-blade computer, you may install the
blade into either of the two modules, however, we recommend that you install the blade in the module
directly above the computer controller.
To install the blade, do the following:
1. Locate the card guide rails.
2. Place the blade onto the card guide rails.
3. Slide the card slowly into the slot until the front panel of the blade is about one inch from the
chassis.
Note: You may experience some resistance when you slide the blade into place, however,
this is normal behavior.
4. Verify that the ejectors and thumb fasteners are aligned with the inner mounting rails on
BreakingPoint Storm.
5. Push the blade into place after you have verified that the ejectors and thumb fasteners are
properly aligned.
6. Push the ejectors so that they lock the blade into place.
7. Tighten the thumb fasteners by turning them in a clockwise direction.
8. Insert an XFP optical transceiver into each data port.
Chapter 5 Installation Guide
– 36 –
Note: Any unused optical transceiver must be covered with the rubber dust cover. This
will prevent the optical data port from damage and protect your eyes from the Class 1
lasers.
Powering the Computer
Before connecting any power cables to the chassis, verify the following:
l The chassis has been securely fastened into an equipment rack.
l There is an AC power disconnect installed for the equipment rack, and it is easily accessible.
l The main AC power disconnect for the rack is properly labeled.
l All of the installation steps have been followed and all site and safety requirements have been
met.
l All the power switches are in the off position.
After you have verified all of this information, you may proceed to the instructions for powering the
chassis.
To connect the power cables to the chassis, do the following:
1. Insert the female end of the supplied power cable into the power inlet, which is located on the
back of the chassis.
2. Insert the male end of the cable into an AC outlet.
3. Turn the power switch to Reset.
After you have turned on the power for the chassis, you can proceed to the initial configuration for the
computer. For more information, see Initial Configuration.
Note: Do not remove the fan tray while BreakingPoint Storm is powered on. Power the computer
off and wait until the fans have stopped running before removing the fan tray from the computer.
Connecting a Device Under Test to BreakingPoint Storm
After mounting and configuring BreakingPoint Storm, you can connect your device(s) under test to the
computer.
Note: The computer can be powered on when you connect the device under test to
BreakingPoint Storm.
To connect a device under test to the chassis, do the following:
1. Locate a free data port on the chassis.
2. Connect one end of a supplied fiber-optic cable to the data port.
3. Connect the other end of the fiber-optic cable to a port on the device under test.
4. Repeat the preceding three steps for any additional optical data port connections.
Chapter 5 Installation Guide
– 37 –
CHAPTER 6 System Configuration
This section covers the following:
l Initial Configuration
Initial Configuration
During an initial configuration, set up the IP address, netmask, and gateway for BreakingPoint Storm.
Additionally, during this process, create a user account that you can use to log on to the Control
Center.
Note: FireStorm ONE does not assign privilege levels to any accounts. Therefore, all accounts
have the same access rights.
Default Network Settings
On the initial boot-up of the computer, it will use the default network settings defined in the following
table:
Network Setting
Default Setting
Host Address
10.10.10.10
Netmask
255.255.255.0
Gateway
10.10.10.1
Computer Configuration
You can perform a computer configuration by using one of two methods:
l Telnet: Use telnet if connecting to the BPS management ethernet port.
l Text Console: Use a text console if connecting to the BPS management serial port.
Telnet
To configure BreakingPoint Storm through telnet, the appliance must be connected to your network
(that is, hub or router) through the BPS management ethernet port.
To configure the computer through telnet, do the following:
1. Open a telnet client or telnet capable CLI application (for example, PuTTy or AlphaCom).
2. Telnet to the following address: 10.10.10.10.
– 39 –
3. Specify your terminal emulation preference at the prompt (ANSI or xterm).
4. Press Enter.
5. Specify the following information in the Network Information box:
l DHCP Enable/Disable
Note: If DHCP is turned off, you can configure additional computer routes from the
Routes tab in the Administration area of the Control Center. If DHCP is turned on,
the Routes area will be unavailable.
l DHCP Hostname
l IP Address
l Netmask
l Gateway
6. Click Next.
7. Type the login name that you want to use for the first user account at the prompt.
8. Type the password for the user account.
9. Press Enter.
The computer disconnects while the new network settings are applied and the account is created.
Note: Document the host address and user account information configured for BreakingPoint
Storm. You will need this information to access and log on to the Control Center. After you have
logged on, you can create additional user accounts, if necessary, through the Administration
area of the Control Center.
Text Console
To configure BreakingPoint Storm through a text console, connect the appliance to a computer through
the BPS management serial port.
To configure the network settings through text console, do the following:
1. Open a terminal emulation client (for example, HyperTerminal or Minicom).
2. Connect to the BPS management serial port by using the following settings:
l Baud Rate: 115200 bps
l Data Bits: 8
l Parity: None
l Stop Bits: 1
l Flow Control: None
3. Specify the following information in the Network Information box:
l DHCP Enable/Disable
Note: If DHCP is turned off, you can configure additional computer routes from the
Routes tab in the Administration area of the Control Center. If DHCP is turned on,
the Routes area will be unavailable.
l DHCP Hostname
Chapter 6 System Configuration
– 40 –
l IP Address
l Netmask
l Gateway
4. Click Next when you are done inputting your network settings.
5. Type the login ID that you will use for the user account at the prompt.
6. Type the password for the user account at the prompt.
7. Press Enter.
The computer disconnects while the new network settings are applied and your new account is created.
Note: Document the host address and user account information configured for BreakingPoint
Storm. You will need this information to access and log on to the Control Center. After you have
logged on, you can create additional user accounts, if necessary, through the Administration
area of the Control Center.
Chapter 6 System Configuration
– 41 –
CHAPTER 7 Accessing the Control Center
This section covers the following:
l Accessing the Control Center
Accessing the Control Center
This section describes how to access the Control Center.
You can access the Control Center after you have configured BreakingPoint Storm. When you access
the Control Center, the first page that opens is the BreakingPoint Systems main page. From the main
page, you can download the TCL shell, access Strike Center, view the online Help, find BreakingPoint
Systems contact information, and open the Control Center user interface.
Note: To access the Control Center, you must have a web browser with Adobe Flash installed
and pop-ups turned on as well as the host address of the BPS management port.
Note: We recommend you clearing your cache and refreshing your browser after upgrading or
reverting to any release of FireStorm ONE.
To access the Control Center, do the following:
1. Open a Web browser.
Note: The browser must support Adobe Flash (version 11.6.602.171) and have JavaScript
turned on.
2. Type the host address for the BPS management port in the Address bar.
Note: The default address is http://10.10.10.10, however, if the host address was
changed during the initial configuration, use that address instead.
3. Click Start BreakingPoint Control Center located on the BreakingPoint Systems main page.
A new window appears and opens the Control Center login page.
4. Type the login ID in the Login ID box.
Note: Login IDs are case sensitive.
5. Type the password in the Password box.
– 43 –
6. Click Login.
Note: The computer allows three invalid logins. If you type invalid login information on
the fourth attempt, the login window will lock you out. Refresh the browser to unlock your
accounts.
Note: The e-mail address can use the following special characters: underscores, hyphens,
periods, and spaces.
7. Click Add User (‘+’).
Chapter 7 Accessing the Control Center
– 44 –
CHAPTER 8 Frequently Asked Questions
This section provides answers to some of the most frequently asked questions. If you have any
questions that you would like added to this section, send them to [email protected].
Account Questions
Question: I have had four invalid login attempts to the Control Center, and my account is now locked.
How do I unlock my account?
Answer: Close the Control Center window and open a new browser window.
Question: How do I reset my Control Center account password?
Answer: You can have another user log on to the Control Center to reset your password. You can log
on to the BPS management port to reset the password, or you can telnet to the computer's
management IP address to reset the password.
Question: How do I create a Strike Center account?
Answer: Go to Strike Center and click the Register link located under the Account Options area.
Type your customer ID and license key in the corresponding boxes, and click Validate. If you do not
have your customer ID or license key, please contact the BreakingPoint Systems support team at
[email protected] or call 1-818-595-2599.
The Create Account page appears, which allows you to create a new Strike Center account.
Question: I forgot my Strike Center password. How do I retrieve it?
Answer: Go to Strike Center and click the Register link located under the Account Options area.
You will need to have your customer ID and license key to log on. If you do not have this information,
please contact BreakingPoint Systems support team at [email protected] or call 1-818-595-
2599.
After you log on, locate your account and click the Reset link located next to it. The Password
Reset screen appears, which allows you to reset your account’s password.
Question: Does each user need a Strike Center account?
– 45 –
Answer: No. It is not necessary for each user to have a Strike Center account, however, if you have
multiple boxes, you may want to create an account for each box.
Addressing Questions
Question: How do I configure the computer to use one MAC address per host?
Answer: If you edit the Network Neighborhood selected for your test, you can select 'Host' as the type
for the domain. This will allot one MAC address per host. Selecting 'Virtual Router' uses one MAC
address total for all traffic from that subnet.
Question: Why would I want to use one MAC address for all hosts?
Answer: A device has limited memory dedicated to its ARP table. If it takes too long for the ARP table
to populate, the device may run out of buffer packets for that host and drop packets. So, you will want
to use the 'Virtual Router' option when using more addresses than the device’s ARP table is capable of
handling. Otherwise, entries are dropped before they need to be used.
Question: Can NAT be used across multiple test components?
Answer: No. Only one test component can use a domain that has NAT turned on. Any domain that has
NAT tuned on cannot be shared between test components.
Question: How many subnets can I add to a domain?
Answer: The number of subnets that can be added depends on the type of subnet you are defining.
Each domain can contain one non-VLAN subnet. Each additional subnet must have a VLAN ID assigned
to it. So, theoretically, the limit is 4,095, because you can assign VLAN IDs from 1-4,095.
Question: How do I assign one IP address per subnet?
Answer: If you edit the Network Neighborhood selected for your test, you can turn off the Use
Address Range option and type the single IP address that you want to use in the Minimum Range
field.
Question: What type of Network Address Translation (NAT) is supported?
Answer: Source NAT, also known as Traditional NAT, Outbound NAT, or Unidirectional NAT.
Question: Do you support Destination NAT?
Answer: No.
Chapter 8 Frequently Asked Questions
– 46 –
Question: Can I send and receive traffic on the same interface?
Answer: Yes. You can send and receive traffic on the same interface if you assign the interface a
domain that has VLAN-tagging turned on.
Bandwidth Questions
Question: How do I define the maximum throughput for each test interface?
Answer: The maximum throughput is defined by using the Data Rate parameters. This parameter is
defined per test component, and it is the upper-bound rate for each interface, which means that the
interface will never send more traffic than the value specified. For the session-based components, you
can define the scope of the data rate, which enables you to set the maximum data rate per interface, or
set the aggregate data rate for the entire test component.
Question: What is the maximum throughput for each interface?
Answer: The maximum throughput is determined by the link speed of the device connected to the
appliance. BreakingPoint Storm allows up to 10 Gbps on the 10 Gb blades and 1 Gbps on the 1 Gb
blades.
Question: How do I determine how much bandwidth each test component is using?
Answer: The computer has a test status verification feature that tells you whether or not the test
components have exceeded the maximum allowed bandwidth for each interface. For example, if you
capture 500 Mbps of traffic on Interface 1, the corresponding Recreate test estimates that the data rate
is 500 Mbps for both the transmitting and receiving interfaces. To set the data rate to be an aggregate
sum for the test component, set the Data Rate Scope parameter to Limit Aggregate Throughput.
Question: What is the maximum bandwidth usage for a test interface?
Answer: For test components that send bidirectional traffic, such as Session Sender, Application
Simulator, and Recreate, the value defined for Frame Rate Distribution sets the upper bound limits for
bandwidth usage per interface. However, the aggregate sum of the traffic sent by each interface
fluctuates between the data rate shared between both testing interfaces. For example, if you have a
Session Sender test that uses 500 Mbps, the test never sends more than 500 Mbps from an interface,
however, the sum of traffic sent by both interfaces fluctuates between 500 Mbps and 1000 Mbps.
System Questions
Question: What are the power requirements for BreakingPoint Storm?
Answer: The following are the power requirements for BreakingPoint Storm: 100-240 VAC, 4 A at 50-
60 Hz, and a maximum power consumption of 400 Watts.
Question: What is the manufacturer MAC address for the BPS Management port?
Chapter 8 Frequently Asked Questions
– 47 –
Question: Does the computer support ephemeral ports or application specification modifications that
are required to match the application data to the IP and TCP/UDP headers?
Answer: No. This functionality is currently not supported.
Question: What is the maximum current available for the DUT power receptacle?
Answer: 120 VAC or 8.3 A
Question: Can multiple users use the computer?
Answer: Yes. Multiple users can be logged on to the computer at the same time and multiple tests,
Tcl scripts, and packet captures can be run simultaneously.
Question: How do I restore factory settings?
Answer: There are two ways to restore factory settings: you can do it through the Control Center or
you can manually do it from the physical box.
To restore settings through the Control Center, navigate to the Administration page. Locate the area
labeled System Functions, and then click Factory Revert.
To restore factory settings from the box: First, power cycle the box. After the Status LED is green,
insert a pin-sized object into the Reset button. Continue to push the Reset button until the Status LED
turns red. The Status LED will then turn red and alternatively flash red and green. After this process is
done, the box will reboot. Configure FireStorm ONE after it finishes rebooting.
Question: What is the difference between a factory revert and a previous revert?
Answer: A factory revert rolls the computer back to the build that was initially installed on it (that is,
the factory build) and reverts it back to its factory state. Therefore, all settings, tests, and data stored
on the computer are removed. A previous revert rolls the computer back to the build that was
previously installed on your computer.
Question: What is the difference between a soft reboot and a restart?
Answer: A soft reboot will restart the software processes, whereas restart will power-cycle the box.
Question: When would I use thePreload for slower connections command on the Login page?
Chapter 8 Frequently Asked Questions
– 48 –
Answer: Use the Preload for slower connections command if your connection is slow. Pressing
this button prefetches the application assets and places them into the browser's cache. This reduces
the amount of time it takes for the application to load. When you clear your browser's cache, press the
Preload for slower connections button again on subsequent logins.
Question: How do I know when an OS update or ATI Update is available?
Answer: If you have automatic updates turned on, the computer alerts you that an update has been
downloaded after you log on to the Control Center. However, if you do not have automatic updates
turned on, you will need to check Strike Center periodically for new releases. On the Strike Center
main page, click the OS Updates link for system updates or click the ATI Updates link for ATI
updates.
Question: What ports do I need to be open to allow me to manage the computer?
Answer: You will need to have the following ports available: 80, 443, 8880, and 843.
Question: My computer status says 'System Not Operational.' What should I do?
Answer: There are two cases when this may occur: soon after a computer has been rebooted, or after
the computer has not been rebooted for an extended period of time. Typically, after you reboot your
computer, you should wait at least five minutes before running a test. If you try to run a test before this
time, the computer may show this error. To resolve this error in either case, click Control Center >
Administration from the menu bar, click Restart to reboot your computer, and wait at least five
minutes before using the computer.
Question: Where is the diagnostics file?
Answer: You can download the diagnostics file from the Start page. If you click Diagnostics, you
are prompted to save a ZIP file to your computer. The zip file contains the diagnostics files for the
computer.
Troubleshooting Questions
Question: What should I do if the fan stops running?
Answer: First, power off the computer. After the computer is completely off, remove the fan tray from
its module, and reseat the fan by reinserting it into the module again. After you have reseated the fan
tray, power the computer on. If this does not resolve your issue, contact BreakingPoint Support.
Question: When should I remove the power tray?
Answer: You can remove the power tray if you are experiencing problems with the power supply and
need to ship the power tray to BreakingPoint Systems.
Chapter 8 Frequently Asked Questions
– 49 –
Question: I just installed the latest OS update, however, I could not reconnect. What should I do?
Answer: Clear your cache and refresh the browser.
Question: Where can I download the latest software updates and ATI updates?
Answer: You can download all updates from the Ixia website at: https://support.ixiacom.com >
Software Downloads > BreakingPoint Software.
Question: How will I know that an update is available?
Answer: If you have automatic updates turned on, the computer alerts you that an update file has
been downloaded to your box. If you do not have automatic updates turned on, you will have to
periodically visit Strike Center to check for new releases.
Question: I have automatic updates turned on. Does this install the update for me?
Answer: No. Automatic updates only downloads the update file. You will need to log on to the Control
Center to install the update.
Question: How do I get a Strike Center account?
Answer: Contact our support team at [email protected] or call 1-818-595-2599.
Question: How are the OS update files named?
Answer: Update files use the format X-N.bps. The X refers to the oldest version that you can upgrade
from, and the N refers to the update file’s version.
Question: Will ATI updates update my existingStrike Lists with the latest Strikes?
Answer: All ATI updates populate Smart Strike Lists with current strikes. You must manually update
Standard Strike Lists after applying any ATI upgrade.
Chapter 8 Frequently Asked Questions
– 50 –
APPENDIX A Hardware Specifications
This section details the hardware and software specifications for BreakingPoint Storm.
Hardware Specifications
The following table details the hardware specifications for BreakingPoint Storm:
Hardware Component
Specification
Model
BreakingPoint Storm
Dimensions
Height: 7 inches (17.8 cm)
Width: 17.4 inches (44.2 cm)
Depth: 19.5 inches (49.8 cm)
Shipping Weight: 45 lbs (20.4 kg)
Rack Units: 4 RU
Dual Media Test Interfaces
4 - 10 Gigabit SX/LX fiber-optic ports
Target Control Ports
1 - 10/100/1000 ethernet interface
1 - DB9 serial interface
BPS Management Ports
1 - 10/100/1000 ethernet interface
1 - DB9 serial interface
Power Requirements
100-240 V, 50/60 Hz
Maximum power consumption: 1,200 Watts
Temperature Requirements
Operating: 15° C to 40° C (59° F to 104° F)
Non-operating: -20° C to 70° C (-4° F to 158° F)
Humidity Requirements
Humidity: 5% to 95% relative humidity, non-condensing
Altitude Requirements
No degradation up to 13,000 feet
Software Specifications
The following table details the software specifications for BreakingPoint Storm:
Software
Specification
– 51 –
Supported browsers: Adobe Flash (version 11.6.602.171) enabled browser (Internet
Explorer 10), Mozilla Firefox 18, Chrome, and Safari (Mac)
Not supported: Safari for Windows, and Safari 6.0.2 on Mac OS 10.8.2
Recommended minimum screen resolution: 1024 x 768
Minimum 2 Gb RAM
Telnet Client
Telnet client running VT100 emulation
Serial Client
Serial client running 115200/8/n/l/none
Light-Emitting Diodes
The light-emitting diodes (LEDs) status indicators are located on the front of BreakingPoint Storm. See
the following table for descriptions of each LED and what each LED color represents:
LED
Color
Status
Description
Link LED
Green
Operational
Link is present.
Active
LED
Blinking
Green
Operational
Link is present and traffic is on the bus.
User LED
N/A
N/A
For future release, this LED indicates the user who has
reserved the port.
Reserved
LED
N/A
N/A
For future release, this LED indicates the port group to
which the user belongs.
Status
LED
Amber
Boot-up
Computer is booting up.
Green
Operational
Computer is powered on and operating.
Power LED
Green
Powered
Computer is powered on.
Off
Not
powered
Computer is powered off.
Fan LED
Green
Operational
Fan is on.
Shipping Container Contents
The following table lists the contents of the shipping container:
Quantity
Item
1
BreakingPoint Storm
Appendix A Hardware Specifications
– 52 –
System Controller kit:
2 – DB9M-DB9F serial cables
2 – CAT6 ethernet cables
1 – system controller
1 or 2
10 Gb blade kit:
4 – 10 Gb fiber-optical cable
1 – Domestic AC input cable
4 – XFP optical transceivers
4 – 10-32 x .75 pan screws
1 – International AC input cable
1 – 10 Gb blade
1 – Power adapter cable
1 Gb blade kit:
8 – Ethernet cables
1 – Domestic AC input cable
4 – 10-32 x .75 pan screws
1 – International AC input cable
1 – 1 Gb blade
1 – Power adapter cable
CLI Commands
The following table lists the CLI commands available for the BPS Management port:
Command
Description
Sample Syntax
?
Print a list of commands
?
?
Print help for a command
? addUser
addUser
Add a user to the computer
addUser Joe Smith -
name Joe -
email [email protected]
exit
Exit the shell
exit
help
Print the list of commands with descriptions
help
help
Print help for a command
help addUser
networkInfo
Retrieve network setup information
networkInfo
passwd
Change the password for the account logged on to the
BPS Management port
passwd
Appendix A Hardware Specifications
– 53 –
Reboot the computer
reboot
removeUser
Delete a user account
removeUser Joe
updateNetwork
Configure a network interface
updateNetwork -dhcp
yes -
hostname
test.bpointsys.int -
ip 10.10.10.123 -
netmask 24 -
gw 10.10.10.1
updateNetwork
Switch ports on and off
updateNetwork -http_
off value
HTTP Off:
turns port 80
OFF
updateUser
Modify a user account
updateUser joe -name
Joseph
Smith -email
[email protected]
uptime
Display the computer’s uptime
uptime
userInfo
Query a user’s information
userInfo joe
version
Display the software version
version
Appendix A Hardware Specifications
– 54 –
APPENDIX B Safety Instructions
This appendix describes the various unit safety instructions in English and French.
SAFETY INSTRUCTIONS (English)
CAUTION: Safety Instructions
Use the following safety guidelines to help ensure your own personal safety and to help protect your
equipment and working environment from potential damage.
SAFETY: General Safety
CAUTION
The power supplies in your system may produce high voltages and energy hazards, which can cause
bodily harm. Only Ixia service technicians are authorized to remove the cover and access any of the
components inside the system.
CAUTION
To reduce the risk of electrical shock, a trained service technician must disconnect all power supply
cables before servicing the system.
Note: The installation of your equipment and rack kit in a rack cabinet has not been approved
by any safety agencies. It is your responsibility to ensure that the final combination of
equipment and rack complies with all applicable safety standards and local electric code
requirements. Ixia disclaims all liability and warranties in connection with such combinations.
Rack kits are intended to be installed in a rack by trained service technicians.
When setting up the equipment for use:
l Place the equipment on a hard, level surface.
l Leave 5.1 cm (2 in) minimum clearance on all vented sides of the equipment to permit the airflow
required for proper ventilation. Restricting airflow can damage the equipment.
l Ensure that nothing rests on your equipment’s cables and that the cables are not located where
they can be stepped on or tripped over.
l Keep your equipment away from radiators and heat sources.
l
Keep your equipment away from extremely hot or cold temperatures to ensure that it is used
within the specified operating range.
Do not stack equipment or place equipment so close together that it is subject to re-circulated or
preheated air.
Appendix B Safety Instructions
– 55 –
When operating your equipment:
CAUTION: Do not operate your equipment with the cover removed.
l Use this product only with approved / certified equipment. Operate this product only with
approved /certified redundant power supplies.
l Operate the equipment only from the type of external power source indicated on the electrical
ratings label. If you are not sure of the type of power source required, consult your service
provider or local power company.
l Use only approved power cable(s). If you have not been provided with a power cable for the
equipment or for any AC-powered option intended for the equipment, purchase a power cable that
is approved for use in your country. The power cable must be rated for the equipment and for the
voltage and current marked on the equipment’s electrical ratings label. The voltage and current
rating of the cable should be greater than the ratings marked on the equipment.
l Do not modify power cables or plugs. Consult a licensed electrician or your power company for
site modifications. Always follow your local/national wiring rules.
l To help prevent electric shock, plug the equipment’s power cable into properly grounded
electrical outlets. These cables are equipped with three-prong plugs to help ensure proper
grounding. Do not use adapter plugs or remove the grounding prong from a cable. If you must use
an extension cable, use a 3-wire cable with properly grounded plugs.
l Observe extension cable and power strip ratings. Ensure that the total ampere rating of all
equipment plugged into the extension cable or power strip does not exceed 80 percent of the
ampere ratings limit for the extension cable or power strip.
l If any of the following conditions occur, unplug the equipment from the electrical outlet and
replace the part or contact Ixia:
n The power cable, extension cable, or plug is damaged.
n An object has fallen into the equipment.
n The equipment has been exposed to water.
n The equipment has been dropped or damaged.
n The equipment does not operate correctly when you follow the operating instructions.
l Do not operate the equipment within a separate enclosure unless adequate intake and exhaust
ventilation are provided on the enclosure that adheres to the guidelines listed above.
l Do not restrict airflow into the equipment by blocking any vents or air intakes.
l Do not push any objects into the air vents or openings of your equipment. Doing so can cause fire
or electric shock by shorting out interior components.
CAUTION:
Only Ixia trained service technicians are authorized to replace the battery. Should the battery need to
be replaced, please contact Ixia to arrange for the replacement of the battery. Incorrectly installing or
using an incompatible battery may increase the risk of fire or explosion. Replace the battery only with
the same or equivalent type recommended by the manufacturer, carefully following installation
instructions. Dispose of used batteries properly.
Appendix B Safety Instructions
– 56 –
SAFETY: Battery Disposal
Your system uses a lithium coin-cell battery. These batteries are long-life batteries, and it is very
possible that you will never need to replace them. However, should you need to do so, please contact
Ixia to arrange for the replacement of the battery.
Do not dispose of the battery along with ordinary waste. Contact your local waste disposal agency for
the address of the nearest battery deposit site.
Handle batteries carefully. Do not disassemble, crush or puncture batteries. Do not short external
contacts, dispose of batteries in fire or water, or expose batteries to temperatures higher than 60
degrees Celsius (140 degrees Fahrenheit). Do not attempt to open or service batteries. Replace
batteries only with batteries designated for the equipment.
SAFETY: Risk of Electrical Shock
CAUTION:
Opening or removing the cover of this equipment may expose you to risk of electrical shock.
Components inside these compartments should be serviced only by an Ixia service technician.
Allow the equipment to cool before removing add-in modules. Add-in modules may become very warm
during normal operation. Use care when removing add-in modules after their continuous operation.
To help avoid the potential hazard of electric shock, do not connect or disconnect any cables or
perform maintenance or reconfiguration of your equipment during an electrical storm.
SAFETY: Equipment with Laser Devices
CAUTION:
Do not look directly into a fiber-optic transceiver or into the end of a fiber-optic cable. Fiber-optic
transceivers contain laser light sources that can damage your eyes.
This equipment may contain optical communications transceivers which have built-in laser devices. To
prevent any risk of exposure to laser radiation, do not disassemble or open any optical transceiver
assembly for any reason.
Protecting Against Electrostatic Discharge
CAUTION:
Appendix B Safety Instructions
– 57 –
Disconnect product from mains power source in accordance with product-specific safety information
located in this manual.
Electrostatic discharge (ESD) events can harm electronic components. Under certain conditions, ESD
may build up on your body or an object and then discharge into another object, such as your add-in
modules. To prevent ESD damage, you should discharge static electricity from your body before you
handling add-in modules.
You can protect against ESD and discharge static electricity from your body by touching a metal
grounded object before you interact with anything electronic. When connecting other devices to this
equipment, you should always ground both yourself and the other device before connecting it to this
equipment.
You can also take the following steps to prevent damage from electrostatic discharge:
l When unpacking a static-sensitive component from its shipping carton, do not remove the
component from the antistatic packing material until you are ready to install the component. Just
prior to unwrapping the antistatic package, be sure to discharge static electricity from your body.
l When transporting a sensitive component, first place it in an antistatic container or packaging.
l Handle all electrostatic sensitive components in a static-safe area. If possible, use antistatic floor
pads and work bench pads.
SAFETY INSTRUCTIONS (French)
AVERTISSEMENT: Instructions relatives à la sécurité
Veuillez suivre les directives de sécurité suivantes afin d’assurer votre sécurité personnelle et de
protéger votre équipement et votre environnement de travail contre les dommages potentiels.
SÉCURITÉ : Sécurité générale
AVERTISSEMENT:
les sources d’alimentation de votre système peuvent produire une tension élevée et des dangers
électriques qui peuvent causer des blessures corporelles. Seuls les techniciens de service d’Ixia sont
autorisés à retirer le couvercle et à accéder aux composants à l’intérieur du système.
AVERTISSEMENT:
Afin de réduire le risque de choc électrique, un technicien de service formé devra débrancher tous les
câbles d’alimentation avant d’effectuer l’entretien sur le système.
REMARQUE:
Appendix B Safety Instructions
– 58 –
’l’installation de votre équipement et de votre ensemble de bâti dans une armoire n’a été approuvée
par aucune agence de sécurité. Il vous incombe d’assurer que la combinaison finale d’équipements et
de bâtis soit conforme à toutes les normes de sécurité applicables et aux exigences du code local en
matière d’électricité. Ixia décline toute responsabilité et toutes les garanties relatives à de telles
combinaisons. Les ensembles de bâtis sont prévus pour être installés par un technicien de service
formé.
Lors de l’installation de l’équipement aux fins d’utilisation:
l Placer l’équipement sur une surface dure et à niveau.
l Laisser un espace d’au moins 5.1 cm (2 po) sur tous les côtés de l’équipement dotés de fentes
d’aération afin de permettre la circulation d’air nécessaire à une bonne ventilation. L’entrave à la
circulation d’air peut endommager l’équipement.
l S’assurer que rien ne se trouve sur les câbles de l’équipement et que les câbles ne se trouvent
pas dans un endroit où on pourrait marcher ou trébucher sur eux.
l Tenir l’équipement éloigné des radiateurs et autres sources de chaleur.
l Ne pas exposer l’équipement à des températures extrêmement chaudes ou froides afin d’assurer
qu’il soit utilisé dans la plage de fonctionnement spécifiée.
l Ne pas empiler l’équipement ni placer ses composants si près les uns des autres qu’ils risquent
d’être exposés à de l’air de recirculation ou préchauffé.
Lors de l’utilisation de votre équipement:
AVERTISSEMENT: ne pas utiliser votre équipement avec le couvercle retiré.
l Utiliser ce produit uniquement avec des équipements approuvés/certifiés. Faire fonctionner ce
produit uniquement avec des ’alimentations redondantes approuvées/certifiées.
l Faire fonctionner l’équipement uniquement avec le type d’alimentation externe indiqué sur
l’étiquette des caractéristiques électriques. ’En cas de doute quant au type d’alimentation requis,
consulter votre prestataire de services ou la compagnie d’électricité locale.
l Utiliser uniquement des câbles d’alimentation approuvés. Si on ne vous a pas fourni de câble
d’alimentation pour l’équipement ou pour toute autre option alimentée au CA prévue pour
l’équipement, acheter un câble d’alimentation approuvé pour utilisation dans votre pays. Le câble
d’alimentation doit être conforme aux caractéristiques nominales de l’équipement, ainsi qu’aux
valeurs nominales de tension et de courant indiquées sur l’étiquette des caractéristiques
électriques de l’équipement. Les valeurs nominales de tension et de courant du câble doivent
être supérieures à celles indiquées sur l’équipement.
l Ne pas modifier les câbles d’alimentation ou les fiches. Consulter un électricien agréé ou votre
compagnie d’électricité pour toute modification du site. Systématiquement respecter les règles
locales/ nationales en matière de câblage.
l Pour prévenir les chocs électriques, brancher les câble d’alimentation de l’équipement dans des
prises électriques mises à la terre correctement. Ces câbles sont dotés de fiches à trois branches
afin d’assurer une mise à la terre adéquate. Ne pas utiliser de fiches d’adaptation ni retirer la
broche de mise à la terre d’un câble. Si ’une rallonge doit absolument être utilisée, utiliser un
câble à trois fils doté de fiches de mise à la terre adéquates.
l Respecter les caractéristiques nominales ’de la rallonge et de la barrette d’alimentation.
Appendix B Safety Instructions
– 59 –
S’assurer que l’ampérage nominal total de tous les équipements branchés ’à la rallonge ou à la
barrette d’alimentation n’excède pas 80 pour cent de l’ampérage nominal maximal ’de la rallonge
ou de la barrette d’alimentation.
l Si l’une des situations suivantes se produit, débrancher l’équipement de la prise de courant et
remplacer la pièce ou contacter Ixia:
n Le câble d’alimentation, ’la rallonge ou la fiche est endommagé.
n Un objet est tombé dans l’équipement.
n L’équipement a été exposé à de l’eau.
n L’équipement est tombé ou a été endommagé.
n L’équipement ne fonctionne pas correctement quand vous suivez les consignes d’utilisation.
n Ne pas utiliser l’équipement dans une enceinte séparée à moins qu’une ventilation d’entrée
et de sortie d’air adéquate soit fournie sur cette enceinte en conformité avec les directives
indiquées ci-dessus.
n Ne pas ’’entraver l’arrivée d’air dans l’équipement en bloquant les fentes d’aération ou les
entrées d’air.
n Ne pas introduire d’objets dans les fentes ’d’aération ou ouvertures de votre équipement au
risque de causer un incendie ou un choc électrique à la suite d’un court-circuit des
composants internes.
AVERTISSEMENT:
seuls les techniciens de service formés d’Ixia sont autorisés à remplacer la pile. Si la pile doit être
remplacée, contacter Ixia pour prendre les dispositions nécessaires au remplacement de la pile.
L’installation incorrecte ou l’utilisation d’une pile incompatible peut augmenter le risque d’incendie ou
d’explosion. Remplacer la pile uniquement par un type de pile identique ou équivalent conformément
aux recommandations du fabricant et suivre les consignes d’installation à la lettre. Correctement
éliminer les piles usées.
SÉCURITÉ : Élimination des piles
Votre système utilise une pile bouton au lithium. Ces piles sont à longue durée et il est très
possible que vous n’ayez jamais à les remplacer. Toutefois, si jamais vous deviez le faire, veuillez
contacter Ixia pour prendre les dispositions nécessaires au remplacement de la pile.
Ne pas éliminer la pile avec les ordures ménagères. ’Contacter l’agence locale chargée de l’élimination
des déchets pour obtenir l’adresse du site de collecte de piles le plus proche.
Manipuler les piles avec précaution. Ne pas démonter, écraser ou percer les piles. Ne pas court-
circuiter les contacts externes, éliminer les piles dans le feu ou l’eau, ni exposer les piles à des
températures supérieures à 60 degrés Celsius (140 degrés Fahrenheit). Ne pas essayer d’ouvrir ou de
’réparer les piles. Remplacer les piles uniquement avec les piles désignées pour l’équipement.
SÉCURITÉ : Risque de choc électrique
Appendix B Safety Instructions
– 60 –
ouvrir ou retirer le couvercle de cet équipement peut vous exposer à un risque de choc électrique. Les
composants à l’intérieur de ces compartiments doivent être entretenus exclusivement par un
technicien de service Ixia.
l Laisser l’équipement refroidir avant de retirer les modules additionnels. Les modules additionnels
peuvent devenir très chauds lors du fonctionnement normal. Faire preuve de prudence lors du
retrait de modules additionnels après un fonctionnement continu.
l Pour éviter le risque potentiel de choc électrique, ne pas connecter ou déconnecter les câbles, ni
effectuer l’entretien ou la reconfiguration de votre système durant une tempête électrique.
SÉCURITÉ : Équipement doté de dispositifs laser
AVERTISSEMENT:
ne jamais regarder directement dans un émetteur-récepteur à fibres optiques ou dans l’extrémité d’un
câble à fibres optiques. Les émetteurs-récepteurs à fibres optiques contiennent des sources de lumière
laser qui peuvent endommager vos yeux.
Cet équipement peut contenir des émetteurs-récepteurs de communication par fibre optique qui
comportent des dispositifs laser intégrés. Pour prévenir tout risque d’exposition au rayonnement laser,
ne jamais démonter ou ouvrir un émetteur-récepteur à fibres optiques.
Protection contre les décharges électrostatiques
AVERTISSEMENT:
débrancher le produit de la source principale d’alimentation conformément aux informations de
sécurité spécifiques au produit fournies dans ce manuel.
Les décharges électrostatiques peuvent endommager les composants électroniques. Dans certaines
conditions, les décharges électrostatiques peuvent s’accumuler sur votre corps ou sur un objet, puis se
décharger dans un autre objet comme vos modules additionnels. Pour prévenir les dommages dus aux
décharges électrostatiques, vous devez décharger l’électricité statique de votre corps avant de
manipuler un module additionnel.
Vous pouvez assurer la protection contre les décharges électrostatiques et décharger l’électricité
statique de votre corps en touchant un objet en métal mis à la terre avant ’de toucher quoi que ce soit
d’électronique. Lors de la connexion d’autres dispositifs à cet équipement, vous devez toujours assurer
votre mise à la terre et celle de l’autre dispositif avant de le connecter à cet équipement.
Vous pouvez aussi suivre les étapes suivantes afin de prévenir les dommages causés par les
décharges électrostatiques:
Appendix B Safety Instructions
– 61 –
l Lors du retrait d’un composant sensible à l’électricité statique de son carton d’expédition, ne pas
retirer le composant de son matériau d’emballage antistatique ’avant d’être prêt à installer ce
composant. Juste avant de retirer l’emballage antistatique, ’veiller à décharger l’électricité
statique de votre corps.
l Lors du transport d’un composant sensible, le placer préalablement dans un contenant ou un
emballage antistatique.
l Manipuler tous les composants sensibles à ’l’électricité statique dans une zone à protection
antistatique. Si possible, utiliser des tapis antistatiques pour le sol et la surface de travail.
Appendix B Safety Instructions
– 62 –
Adobe Flash player 15
altitude 30
ATI updates 50
B
BNC interfaces 6
BPS management ethernet port 5
BreakingPoint Control Center 15
C
CE mark certification 31
class 1 lasers 30
clock I/O 6
connection type 20
Control Center 6
D
data ports 5
degradation 30
device selection 20
device status 9, 17
DHCP enable/disable 13
diagnostics files 49
DUT profile 19
E
EIA-310-C 31
EIA-310C 29
electrostatic discharge 30
equipment rack 12, 33
ethernet address 23
F
FCC rules 31
force reserve 25
G
gateway 12
gateway IP address 22
H
host 46
host address 12
humidity 30
I
initial configuration 39
J
JavaScript 6, 15
L
locked account 45
– 63 –
login ID 8, 43
M
MAC address 46
management COM port 13
maximum IP address 23
menu bar 9, 17
minimum IP address 23
N
NAT 46
navigational buttons 9, 17
netmask 12
network IP address 13
network neighborhood 20
network settings 12
non-operating environment 30
O
operating environment 30
optical transceivers 30
P
password 8, 43
port notes 25
port reservations 24
power cable 37
power inlet 6
power switch 6
preload for slower connections 48
R
reset password 45
router IP address 23
S
strike center account 50
strike center password 50
subnet 20
system fan tray 5
T
telnet 12
telnet client 13
terminal emulation client 13
test 26
test interface 20
text console 12
time and date 18
trigger I/O 6
U
UL-60950-1 31
use address range 23
V
virtual router 23, 46
X
XFP optical receivers 30
INDEX
– 64 –
Ixia, a Keysight Business
26601 West Agoura Road
Calabasas, California 91302
© Keysight Technologies, 2005–2018