Keysight N432A Installation Manual
Read Online
Read the Keysight N432A Installation Manual online using the built-in PDF viewer.
Text of the manual
Keysight N432A Installation Guide
Notices
Copyright Notice
© Keysight Technologies 2010-2017
No part of this manual may be repro-
duced in any form or by any means
(including electronic storage and
retrieval or translation into a foreign
language) without prior agreement and
written consent from Keysight Technol-
ogies as governed by United States and
international copyright laws.
Manual Part Number
N432A-90000
Edition
Edition 5, December 1, 2017
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies
Bayan Lepas Free Industrial Zone,
11900 Penang, Malaysia
Technology Licenses
The hardware and/or software
described in this document are fur-
nished under a license and may be
used or copied only in accordance with
the terms of such license.
Declaration of Conformity
Declarations of Conformity for this
product and for other Keysight prod-
ucts may be downloaded from the
Web. Go to http://www.keysight.com/
go/conformity. You can then search by
product number to find the latest Dec-
laration of Conformity.
U.S. Government Rights
The Software is “commercial computer
software,” as defined by Federal Acqui-
sition Regulation (“FAR”) 2.101. Pursu-
ant to FAR 12.212 and 27.405-3 and
Department of Defense FAR Supple-
ment (“DFARS”) 227.7202, the U.S.
government acquires commercial com-
puter software under the same terms
by which the software is customarily
provided to the public. Accordingly,
Keysight provides the Software to U.S.
government customers under its stan-
dard commercial license, which is
embodied in its End User License
Agreement (EULA), a copy of which can
be found at http://www.keysight.com/
find/sweula. The license set forth in the
EULA represents the exclusive authority
by which the U.S. government may use,
modify, distribute, or disclose the Soft-
ware. The EULA and the license set
forth therein, does not require or per-
mit, among other things, that Keysight:
(1) Furnish technical information
related to commercial computer soft-
ware or commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish
to, or otherwise provide, the govern-
ment rights in excess of these rights
customarily provided to the public to
use, modify, reproduce, release, per-
form, display, or disclose commercial
computer software or commercial com-
puter software documentation. No
additional government requirements
beyond those set forth in the EULA
shall apply, except to the extent that
those terms, rights, or licenses are
explicitly required from all providers of
commercial computer software pursu-
ant to the FAR and the DFARS and are
set forth specifically in writing else-
where in the EULA. Keysight shall be
under no obligation to update, revise or
otherwise modify the Software. With
respect to any technical data as
defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS
227.7102, the U.S. government
acquires no greater than Limited Rights
as defined in FAR 27.401 or DFAR
227.7103-5 (c), as applicable in any
technical data.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING
CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO THE
MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT DIS-
CLAIMS ALL WARRANTIES, EITHER
EXPRESS OR IMPLIED, WITH REGARD
TO THIS MANUAL AND ANY INFORMA-
TION CONTAINED HEREIN, INCLUD-
ING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS
OR FOR INCIDENTAL OR CONSE-
QUENTIAL DAMAGES IN CONNECTION
WITH THE FURNISHING, USE, OR
PERFORMANCE OF THIS DOCUMENT
OR OF ANY INFORMATION CON-
TAINED HEREIN. SHOULD KEYSIGHT
AND THE USER HAVE A SEPARATE
WRITTEN AGREEMENT WITH WAR-
RANTY TERMS COVERING THE MATE-
RIAL IN THIS DOCUMENT THAT
CONFLICT WITH THESE TERMS, THE
WARRANTY TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.
Safety Information
CAUTION
A CAUTION notice denotes a hazard. It
calls attention to an operating proce-
dure, practice, or the like that, if not
correctly performed or adhered to,
could result in damage to the product
or loss of important data. Do not pro-
ceed beyond a CAUTION notice until
the indicated conditions are fully
understood and met.
WARNING
A WARNING notice denotes a hazard. It
calls attention to an operating proce-
dure, practice, or the like that, if not
correctly performed or adhered to,
could result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated conditions are
fully understood and met.
Keysight N432A Installation Guide
3
Certification
Keysight Technologies certifies that this product met its published specifications
at the time of shipment. Keysight further certifies that its calibration
measurements are traceable to the United States National Institute of Standard
and Technology (formerly National Bureau of Standards), to the extent allowed by
that organization’s calibration facility, and to the calibration facilities of other
International Standards Organization members.
General Warranty
The material contained in this document is provided “as is,” and is subject to
being changed, without notice, in future editions. Further, to the maximum extent
permitted by applicable law, Keysight disclaims all warranties, either express or
implied with regard to this manual and any information contained herein,
including but not limited to the implied warranties of merchantability and fitness
for a particular purpose. Keysight shall not be liable for errors or for incidental or
consequential damages in connection with the furnishing, use, or performance of
this document or any information contained herein. Should Keysight and the user
have a separate written agreement with warranty terms covering the material in
this document that conflict with these terms, the warranty terms in the separate
agreement shall control. Duration and conditions of warranty for this product may
be superseded when the product is integrated into (becomes a part of) other
Keysight products. During the warranty period, Keysight will, at its option, either
repair or replace products which prove to be defective. The warranty period begins
on the date of delivery or on the date of installation if installed by Keysight.
Warranty Service
For warranty service or repair, this product must be returned to a service facility
designated by Keysight. For products returned to Keysight for warranty service,
the Buyer shall prepay shipping charges to Keysight and Keysight shall pay
shipping charges to return the product to the Buyer. However, the Buyer shall pay
all shipping charges, duties, and taxes for products returned to Keysight from
another country.
Keysight N432A Installation Guide
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or
inadequate maintenance by the Buyer, Buyer-supplied products or interfacing,
unauthorized modification or misuse, operation outside of the environmental
specifications for the product, or improper site preparation or maintenance.
The design and implementation of any circuit on this product is the sole
responsibility of the Buyer. Keysight does not warrant the Buyer’s circuitry or
malfunctions of Keysight products that result from the Buyer’s circuitry. In
addition, Keysight does not warrant any damage that occurs as a result of the
Buyer’s circuit or any defects that result from Buyer-supplied products.
To the extent allowed by local law, Keysight makes no other warranty, expressed
or implied, whether written or oral with respect to this product and specifically
disclaims any implied warranty or condition of merchantability, fitness for a
particular purpose, or satisfactory quality.
Exclusive Remedies
To the extent allowed by local law, the remedies provided herein are the Buyer’s
sole and exclusive remedies. Keysight shall not be liable for any direct, indirect,
special, incidental, or consequential damages (including lost profit or data),
whether based on warranty, contract, tort, or any other legal theory.
Keysight N432A Installation Guide
5
Safety Symbols
The following symbols on the instrument and in the documentation indicate
precautions which must be taken to maintain safe operation of the instrument.
Direct current (DC)
Off (mains supply)
Alternating current (AC)
On (mains supply)
Both direct and alternating current
Caution, risk of electric shock
Three-phase alternating current
Caution, risk of danger (refer to this
manual for specific Warning or Caution
information)
Earth (ground) terminal
Caution, hot surface
Protective earth (ground) terminal
Out position of a bi-stable push control
Frame or chassis (ground) terminal
In position of a bi-stable push control
Equipotentiality
Equipment protected throughout by
double insulation or reinforced
insulation
This symbol indicates that a device, or
part of a device, may be susceptible to
electrostatic discharges (ESD) which
can result in damage to the product.
Observe ESD precautions given on the
product, or its user documentation,
when handling equipment bearing this
mark.
This symbol indicates the operating
switch for ‘Stand-by’ mode.
Note, this instrument is NOT isolated
from the mains when the switch is
pressed. To isolate the instrument, the
mains coupler (mains input cord)
should be removed from the power
supply.
Keysight N432A Installation Guide
Safety Considerations
Read the information below before using this instrument.
The following general safety precautions must be observed during all phases of
operation, service, and repair of this instrument. Failure to comply with these
precautions or with specific warnings elsewhere in this manual violates safety
standards for design, manufacture, and intended use of the instrument. Keysight
Technologies assumes no liability for the customer’s failure to comply with these
requirements.
General Safety Information
This is a Safety Class I instrument (provided with a protective earthing ground
incorporated in the power cord). The mains plug shall only be inserted in a socket
outlet provided with a protective earth contact. Any interruption of the protective
conductor inside or outside the instrument is likely to make the instrument
dangerous. Intentional interruption is prohibited.
all-guides.co
m
Keysight N432A Installation Guide
7
WARNING
– Do not operate the product in an explosive atmosphere or in the presence
of flammable gases or fumes.
– Do not use repaired fuses or short-circuited fuseholders. For continued
protection against fire, replace the line fuse(s) only with fuse(s) of the
same voltage and current rating and type.
– Do not perform procedures involving cover or shield removal unless you
are qualified to do so. Operating personnel must not remove equipment
covers or shields. Procedures involving the removal of covers and shields
are for use by service-trained personnel only.
– Do not service or adjust alone. Under certain conditions, dangerous
voltages may exist even with the equipment switched off. To avoid
electrical shock, service personnel must not attempt internal service or
adjustment unless another person capable of rendering first aid and
resuscitation, is present.
– Do not operate damaged equipment. Whenever it is possible that the
safety protection features built into this product have been impaired,
either through physical damage, excessive moisture, or any other reason,
REMOVE POWER and do not use the product until safe operation can be
verified by service-trained personnel. If necessary, return the product to
Keysight for service and repair to ensure the safety features are
maintained.
– Do not substitute parts or modify equipment. Because of the danger of
introducing additional hazards, do not install substitute parts or perform
any unauthorized modification to the product. Return the product to
Keysight for service and repair to ensure the safety features are
maintained.
Keysight N432A Installation Guide
Environmental Conditions
The N432A is designed for indoor use and in an area with low condensation. The
table below shows the general environmental requirements for this instrument.
Environmental condition
Requirement
Temperature
Operating condition
– 0 °C to 45 °C
Storage condition
– –40 °C to 70 °C
Humidity
Operating condition
– 15% to 95% RH at 40°C (non-condensing)
Storage condition
– Up to 90% RH at 65°C (non-condensing)
Altitude
Up to 4600 m (15000 ft.)
Keysight N432A Installation Guide
9
Ventilation and Cleaning
Ventilation requirements
To provide adequate ventilation, an air gap of approximately 75 mm (3 in.) should
be maintained around the vented sections of the N432A.
Cleaning
Use a soft, lint- free, slightly dampened cloth to wipe the front- panel and side
covers. Do not use detergent. Disassembly is not required or recommended for
cleaning.
WARNING
– An appliance coupler (mains input power cord) is a power disconnect
device. Do not position the instrument such that access to the coupler is
impaired.
– For continued protection against fire, replace the line fuse only with the
same type and line rating (250 V, T2.5 H, 20 mm slow blow fuse with high
breaking capacity). The use of other fuses or materials is prohibited.
– No operator serviceable parts inside. Refer servicing to qualified
personnel. To prevent electric shock, do not remove instrument covers.
– If this instrument is not used as specified, the built-in safety protection
features could be impaired. This instrument must be used in normal
conditions only (in which all means for protection are intact).
Keysight N432A Installation Guide
Compliance and Markings
Electromagnetic compatibility (EMC)
This product complies with the essential requirements of the following applicable
European (EC) Directives, and carries the CE marking in accordance to the Low
Voltage Directive (2006/95/EC) and EMC Directive (2004/108/EC).
The EMC test conforms to the IEC61326- 2- 1:2005/EN61326- 2- 1:2006 and
CISPR11:2003/EN55011:2007 (Group 1, Class A). To preserve the EMC
performance of this product, any cable that is worn out or damaged must be
replaced with the same type and specification.
This product also complies with the following EMC standards:
–
Canada: ICES/NMB- 001:2004
–
Australia/New Zealand: AS/NZS CISPR11:2004
Safety
This product conforms to the requirements of the following safety standards:
–
IEC 61010- 1:2001/EN 61010- 1:2001
–
Canada: CAN/CSA- C22.2 No. 61010- 1- 04
–
USA: ANSI/UL 61010- 1:2004
Keysight N432A Installation Guide
11
Sound emission
Herstellerbescheinigung
Diese Information steht im Zusammenhang mit den Anforderungen der
Maschinenlarminformationsverordnung vom 18 Januar 1991.
Sound Pressure LpA < 70 dB.
Am Arbeitsplatz.
Normaler Betrieb.
Nach DIN 45635 T. 19 (Typprufung).
Manufacturers declaration
This statement is provided to comply with the requirements of the German Sound
DIN 45635 T. 19 (Typprufung).
Sound Pressure LpA < 70 dB.
At operator position.
Normal operation.
According to ISO 7779 (Type Test).
all-guides.co
m
Keysight N432A Installation Guide
Responsibilities of the Customer
The customer shall provide:
–
access to the products during the specified periods of coverage to perform
maintenance
–
adequate working space around the products for servicing by Keysight
personnel.
–
access to and use of all information and facilities determined necessary by
Keysight to service and/or maintain the products. (Insofar as these items may
contain proprietary or classified information, the customer shall assume full
responsibility for safeguarding and protection from wrongful use.)
–
routine operator maintenance and cleaning as specified in the Keysight
Operating and Service Manuals.
–
consumables such as replacement fuses, and so on.
Keysight N432A Installation Guide
13
Regulatory Markings
The CE mark is a registered trademark
of the European Community. This CE
mark shows that the product complies
with all the relevant European Legal
Directives.
ICES/NMB-001 indicates that this ISM
device complies with the
Canadian ICES-001.
Cet appareil ISM est conforme a la
norme NMB-001 du Canada.
ISM GRP.1 Class A indicates that this
is an Industrial Scientific and Medical
Group 1 Class A product.
The CSA mark is a registered
trademark of the Canadian
Standards Association.
This symbol is a South Korean Class A
EMC Declaration. This is a Class A
instrument suitable for professional
use and in electromagnetic
environment outside of the home.
This symbol indicates the time period
during which no hazardous or toxic
substance elements are expected to
leak or deteriorate during normal use.
Forty years is the expected useful life
of the product.
The RCM mark is a registered
trademark of the Australian
Communications and Media Authority.
This instrument complies with the
WEEE Directive (2002/96/EC) marking
requirement. This affixed product label
indicates that you must not discard
this electrical or electronic product in
domestic household waste.
Keysight N432A Installation Guide
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/
96/EC
This instrument complies with the WEEE Directive (2002/96/EC) marking
requirement. This affixed product label indicates that you must not discard this
electrical or electronic product in domestic household waste.
Product category:
With reference to the equipment types in the WEEE directive Annex 1, this
instrument is classified as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center,
or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml
for more information.
Sales and Technical Support
To contact Keysight for sales and technical support, refer to the support links on
the following Keysight websites:
–
www.keysight.com/support/N432A
(product-specific information and support, software and
documentation updates)
–
www.keysight.com/find/assist
(worldwide contact information for repair and service)
Keysight N432A Installation Guide
15
Table of Contents
Certification
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
General Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Warranty Service
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Limitation of Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Exclusive Remedies
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety Symbols
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Safety Considerations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
General Safety Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Environmental Conditions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Ventilation and Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Ventilation requirements
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Compliance and Markings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Electromagnetic compatibility (EMC)
. . . . . . . . . . . . . . . . . . . . . . . .10
Safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Sound emission
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Responsibilities of the Customer
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Regulatory Markings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/
EC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Product category:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Sales and Technical Support
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1
Getting Started
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Initial inspection
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Documentation Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Keysight N432A Installation Guide
Conventions Used in This Guide
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Sensor Compatibility
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Adjusting the Carrying Handle
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Front Panel Outlook
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Rear Panel Connections
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Turning On the N432A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Connecting a Thermistor Sensor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Remote Interface Configurations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
USB
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
LAN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
GPIB
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Rack Mounting the N432A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Rack mounting information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Rack mounting a single N432A (using the Option 908 rack mount kit)
50
Rack mounting two N432As together (using the Option 909 rack mount
kit)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
2
Characteristics and Specifications
all-guides.co
m
Keysight N432A Installation Guide
17
List of Figures
Figure 1-1
Found New Hardware Wizard
. . . . . . . . . . . . . . . . . . .39
Figure 1-2
Enabling DHCP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Figure 1-3
LAN network restart pop-up
. . . . . . . . . . . . . . . . . . . .43
Figure 1-4
LAN network manual setup
. . . . . . . . . . . . . . . . . . . . .45
Figure 1-5
Changing the GPIB address
. . . . . . . . . . . . . . . . . . . . .48
Keysight N432A Thermistor Power Meter
Installation Guide
21
1
Getting Started
Introduction
22
Documentation Information
23
Overview
24
Conventions Used in This Guide
25
Sensor Compatibility
25
Adjusting the Carrying Handle
26
Front Panel Outlook
27
Rear Panel Connections
32
Turning On the N432A
33
Connecting a Thermistor Sensor
36
Remote Interface Configurations
38
Rack Mounting the N432A
49
Keysight N432A Installation Guide
Introduction
This guide provides you the information on how to:
–
physically check the N432A thermistor power meter.
–
adjust the carrying handle.
–
switch on the N432A and confirm that it passes the power-on self-test.
–
connect the N432A to a compatible Keysight thermistor sensor.
–
perform a zeroing routine on the thermistor sensor.
–
make connections to the rear panel.
–
use the Keysight IO Libraries Suite to configure the remote
programming interfaces.
–
attach the rack mount kits (supplied with Option 908 or Option 909).
Initial inspection
When you receive your N432A, inspect the unit for any obvious damage such as
broken terminals or cracks, dents, and scratches on the chassis that may occur
during shipment. If any damage is found, notify the nearest Keysight Sales Office
immediately.
Keep the original packaging in case the N432A has to be returned to Keysight in
future. If you return the N432A for service, attach a tag identifying the owner and
model number. Also include a brief description of the problem.
NOTE
Ensure that you have read and understood the preceding safety information
before you proceed.
Keysight N432A Installation Guide
23
Documentation Information
This guide is only part of the information provided. The documentation for the
N432A consists of:
–
the Installation Guide (this manual)
Provides the procedures on how to check your N432A, switch it on, and
connect it to a compatible Keysight thermistor sensor. This information is
presented in English and Japanese.
–
the User’s Guide
Describes how to operate your N432A from the front panel interface to make
measurements using a compatible Keysight thermistor sensor. You can locate
the User’s Guide on the supplied CD-ROM as a PDF file in English and
Japanese.
–
the Programming Guide
Explains how to operate your N432A over a remote interface. You can locate
the Programming Guide on the supplied CD-ROM as a PDF file in English only.
–
the Service Guide
Describes how to carry out performance verification tests and adjustments on
your N432A, as well as provides the disassembly and troubleshooting
information. You can locate the Service Guide on the supplied CD-ROM as a
PDF file in English only.
Printed guides are available by ordering the following options:
–
English-language user’s guide – Option ABA and Option 0BK (additional copy)
–
Japanese-language user’s guide – Option ABJ
NOTE
A printed Programming Guide is also provided with Option 0BK and ABJ, but in
English only. For Option ABA, the printed Programming Guide is available only by
ordering Option 0BF.
There is also a Connectivity Guide available on the Keysight IO Libraries Suite
CD-ROM as a PDF file. This guide helps you to configure your N432A over GPIB,
LAN, and USB remote interfaces.
all-guides.co
m
Keysight N432A Installation Guide
Overview
This guide is divided into the following categories:
–
adjusting the carrying handle
–
front panel outlook
–
rear panel outlook
–
turning on the N432A
–
connecting a thermistor sensor
–
remote interface configurations
–
rack mounting the N432A
–
general specifications
–
compliance and markings
–
regulatory information
–
responsibilities of the customer
For more detailed operating information, refer to the N432A Thermistor Power
Meter User’s Guide and Programming Guide.
Keysight N432A Installation Guide
25
Conventions Used in This Guide
The following conventions are used throughout this guide.
Sensor Compatibility
The N432A is compatible with the Keysight 478A and 8478B thermistor sensors.
The following table lists the frequency range and operating resistance for each of
these thermistor sensors:
This symbol and text represents a labeled key on the N432A front panel
This symbol and text represents a labeled softkey, and is used to indicate that you
should press the unmarked key beside the displayed text
Message
This text represents a displayed message
Parameter
This is used to represent a parameter, value, or title
Softkey
Thermistor sensor model
Frequency range (GHz)
Operating resistance (Ω)
478A
0.01 to 10
200
478A Option H63
0.0001 to 1
200
478A Option H75
0.001 to 1
200
478A Option H76
0.001 to 1
200
8478B
0.01 to 18
200
NOTE
For further information on the thermistor sensors, refer to their respective
manuals.
Keysight N432A Installation Guide
Adjusting the Carrying Handle
Adjust the carrying handle to carry the N432A or to view the display.
To remove the handle, refer to “Rack Mounting the N432A” on page 49.
The carrying handle can be locked into three different positions.
Pull the handle outwards, rotate it to the required position, and release it into
one of the three locks.
Keysight N432A Installation Guide
27
Front Panel Outlook
This section briefly describes the functions of the front panel keys and connectors.
The user’s guide provides more detailed information on how to use them.
These keys are located to the left of the display.
Key
Function
Press this key to preset the N432A to its default state
Press this key to control the N432A from the front panel when it is operating via the
remote interfaces (when Local Lock Out is disabled)
Press this key to select the upper or lower measurement window. The selected
window is highlighted by a blue line on the right of the window. Any measurement
setup you create is performed in the selected window.
Press this key to select a windowed, expanded, or full-screen display of a numeric
measurement
Press this key to switch the N432A between on and standby. When power is
supplied, the background LED turns red. Pressing the key switches on the N432A
and the background LED turns yellow. When the N432A is powered on, the startup
will take approximately 25 seconds.
Keysight N432A Installation Guide
These keys are located along the lower edge of the display.
Key
Function
Press this key to access general configuration menus, such as the remote interface
configuration. You can also access some measurement configuration menus. The
measurement screen remains visible.
Press this key to access the channel configuration menu. Channel parameters such
as voltage averaging and offsets are configured from this menu.
Press this key to access the triggering menu
Press this key to configure measurements for the selected measurement window,
such as display offsets and relative measurements
Press this key to access the measurement display menu. You can select the
displayed measurement resolution, unit, and display format.
Use this key together with
to configure measurement displays.
all-guides.co
m
Keysight N432A Installation Guide
29
These keys are associated with the menu labels and data entry. They are located
to the right of the display.
Key
Function
Press this key to return to the previous screen. This key also cancels pop-up
entries.
These unmarked keys are called ‘softkeys’ and are referred to by the text on the
display next to them.
For example, during a preset, you are given an option to confirm the command.
Press
to continue, that is, press the softkey beside the displayed word
Confirm.
The lowest of the unmarked softkeys is used when there is a two-page menu to be
displayed. For example, a 1 of 2 is displayed beside the key indicating the first page
of a two-page menu. Press the key to access the next page or the second page (a 2
of 2 is displayed).
Confirm
Keysight N432A Installation Guide
These keys and connectors are associated with the measurement channel and are
located on the right of the front panel.
Key
Function
The arrow keys are used for navigation around the parameter entry screens. The up
and down arrows are used for selecting values from a pop-up list. They are also
used to enter text such as table names.
Press this key to select a highlighted field to allow data entry, select a check box,
or confirm the entry of a pop-up list
Press this key to access the zeroing menu
Press this key to reset the MAX HOLD and MIN HOLD measurements
Press these keys to enter numeric values in the pop-up fields, for example, the
offset values. To complete the entry, use the softkey.
Keysight N432A Installation Guide
31
Connector
Function
The power reference is a 1 mW (0 dBm), 50 MHz signal available
from a 50 W type-N connector. It is used for calibrating a 478A or
8478B thermistor sensor and meter system.
The yellow LED beside the connector is lit when turned on.
Thermistor mount input connector for 1.5 m, 3 m, and 6.1 m cables
that connect to the 478A and 8478B thermistor sensors
Keysight N432A Installation Guide
Rear Panel Connections
The following connectors are available on the rear panel. To set up the remote
interfaces, refer to “Remote Interface Configurations” on page 38.
No.
Connection
1
Ground connector
2
Recorder output terminal 1
Recorder output connection is made via a BNC connector. This output produces a DC voltage
that corresponds to the power level of the channel input.
3
AC inlet
The N432A has an autoconfiguring power supply. This allows it to operate over a range of
voltages without manually being set to a certain voltage.
4
VRF and VCOMP output terminals
The VRF BNC terminal outputs the RF bridge voltage, while the VCOMP BNC terminal outputs the
compensation bridge voltage. Both the VRF and VCOMP outputs are used for calibrating the
N432A and for precision power measurements.
5
USB Mini-B port
Allows the N432A to be controlled remotely over the USB interface
6
LAN interface
Allows the N432A to be controlled remotely over the LAN interface
7
GPIB interface
Allows the N432A to be controlled remotely over the General Purpose Interface Bus (IEEE-488)
standard interface
5
6
4
7
2
1
3
Keysight N432A Installation Guide
33
Turning On the N432A
You can turn on the N432A without connecting a thermistor sensor or a thermistor
sensor cable.
NOTE
The N432A has an autoranging power supply. Ensure the supplied voltage is
within the range of 100 Vac to 240 Vac and 50 Hz to 60 Hz and 400 Hz.
1
Connect the power cord.
2
Check that the background LED is red.
all-guides.co
m
Keysight N432A Installation Guide
3
Turn on the N432A and confirm that the background LED is yellow.
4
The N432A will power up within ~25 seconds, and you should see the
following display:
5
The N432A is now ready for use.
NOTE
If the N432A has been stored in extremely cold conditions, beyond its normal
operating range, the display may require a few minutes to warm up and operate
normally.
Keysight N432A Installation Guide
35
What can go wrong?
Problem
Troubleshooting step
The red LED is not lit
– Check that power is supplied to the N432A
– Check the N432A fuses (refer to Step 6 below)
Self-test(s)fails
If there is any self-test failure, the N432A is defective. Contact the
nearest Keysight Service Center (refer to “Sales and Technical
Support” on page 14).
6
Check the in-line fuses.
In-line fuses
Keysight N432A Installation Guide
Connecting a Thermistor Sensor
478A and 8478B thermistor sensor models
Using a Keysight thermistor sensor cable, any Keysight 478A or 8478B thermistor
sensor can be connected to the N432A.
Follow the procedure below to connect a thermistor sensor to the N432A:
1
Connect one end of the thermistor sensor cable to the sensor.
2
Connect the other end of the cable to the channel A input connector.
3
Turn on the N432A.
Keysight N432A Installation Guide
37
4
A message will appear to inform you of the current bridge resistance value
and require you to select a new resistance value or reconfirm the current
resistance value. Use the softkeys to select the desired value.
5
You will then be prompted for confirmation to proceed with zeroing. Press
Confirm to proceed.
6
Another message will appear, prompting you to confirm whether the
thermistor sensor has been disconnected from the RF source. Press Confirm
once you have verified that there is no RF source connected.
7
Zeroing will start automatically. The Zeroing pop-up message will be
displayed during the zeroing process,
Keysight N432A Installation Guide
Remote Interface Configurations
The N432A can be remotely controlled via LAN, USB, and GPIB (IEEE-488)
programming interfaces. This section describes how to set up and configure these
interfaces.
Only one interface should be used at any one time.
To connect the N432A to your PC, configure and verify the connection, you can
use the Keysight IO Libraries Suite or an equivalent.
–
To install the Keysight IO Libraries Suite, follow the instructions in the Keysight
Automation-Ready CD with Keysight IO Libraries Suite provided with the
standard purchase of the N432A.
–
You can also access other information on Keysight IO Libraries at
www.keysight.com/find/iolib.
For more information on configuring the remote interface connectivity, refer to the
Keysight Technologies USB/LAN/GPIB Interfaces Connectivity Guide. If you have
installed the IO Libraries Suite, you can access the connectivity guide from the IO
Libraries Control icon. Alternatively, you can access the connectivity guide via the
Web at www.keysight.com/find/connectivity.
all-guides.co
m
Keysight N432A Installation Guide
39
USB
The USB interface requires no front panel configuration. The USB operation and
configuration is supported by the version of VISA and SICL IO libraries on your PC.
1
After the I/O software has been installed on your PC, connect the N432A to
your PC using the supplied Type A – Mini 5-pin USB cable.
2
The PC will confirm the hardware connection.
3
The Found New Hardware Wizard will automatically start and guide you
through the configuration of the N432A as a USB device. Click Next to install
the software automatically and accept all defaults to complete the installation.
Figure 1-1
Found New Hardware Wizard
NOTE
Before connecting the USB cable, ensure that the I/O software has been
installed on your PC.
Refer to “Remote Interface Configurations” on page 38 for the information on
Keysight IO Libraries software. If you have installed other I/O software, refer to
the documentation that accompanies the software.
Keysight N432A Installation Guide
4
You can use the Connection Expert in the IO Libraries Suite to check the
instrument identification.
5
Now, you can use various programming environments to control the N432A.
For an overview on programming the N432A via USB, refer to the connectivity
guide and the programming guide.
NOTE
If you have installed the Keysight IO Libraries software, you have also installed
low-level drivers. Therefore, you do not need to insert the CD when requested by
the Found New Hardware Wizard.
Keysight N432A Installation Guide
41
LAN
The N432A has three LAN operating modes:
–
Dynamic IP (Dynamic Host Configuration Protocol or DHCP)
–
Auto IP (Local PC Control or isolated (non-site) LAN)
–
Static IP (Manual mode)
Configuring the N432A
–
The IP address, subnet mask, and default gateway can be changed manually
or remotely.
–
The IP address, subnet mask, and default gateway values are stored in
non-volatile memory and are not part of the save/recall function.
Selecting the LAN network type
You can connect and configure your N432A for a site LAN or an isolated (non-site)
LAN.
–
A site LAN is defined as a local area network (LAN) in which PCs and
LAN-enabled instruments are connected to a site LAN (workgroup LAN,
intranet, or enterprise LAN) via optional routers, hubs, and/or switches.
–
An isolated (non-site) LAN is defined as a local area network (LAN) in which
PCs and LAN-enabled instruments are not connected to a site LAN.
Select the LAN network type you will use to connect the N432A to your PC. Then,
follow the procedure that corresponds to your selected LAN network type.
NOTE
The N432A uses the standard VXI-11 protocol for emulating GPIB over a TCP/IP
link.
Keysight N432A Installation Guide
Dynamic mode
In dynamic mode, the IP address, subnet mask, and default gateway values are
obtained from a DHCP server. When you use the DHCP operation, you cannot
configure the IP address, subnet mask, and default gateway values from the front
panel.
Using this dynamic mode does not require a detailed knowledge of your network
configuration.
1
Using a standard LAN patch cable, connect both the PC and the N432A to LAN
outlets.
2
Turn on the N432A.
3
Press
>
to access the Remote Interface display.
Ensure that DHCP is enabled (factory-default state).
To enable the DHCP operation, use the arrow and Select keys to highlight and
select DHCP.
Figure 1-2
Enabling DHCP
NOTE
If the DHCP server cannot be found on your network, the N432A will return to
the auto IP mode, then static mode.
Remote Interfaces
Keysight N432A Installation Guide
43
4
Press
if you need to configure any optional settings.
5
Press
.
A pop-up message will appear for 5 seconds as shown below. Monitor the
Status at the bottom of the display to determine when the server has assigned
an address.
Figure 1-3
LAN network restart pop-up
6
Press
, to return to a measurement screen.
7
If you intend to program over the LAN interface, make sure that you have
installed the I/O software on your PC.
8
Use the Connection Expert utility of the IO Libraries Suite to add the N432A
and verify the connection. When identifying the N432A, it is easiest to use the
IP address that you noted in step 5 above.
9
You can use various programming environments to control the N432A. For an
overview on programming the N432A via LAN, refer to the connectivity guide
and the programming guide.
NOTE
If your LAN does not support DHCP, refer to the connectivity guide.
Network DHCP
Restart Network
NOTE
If you have installed other I/O software, refer to the documentation that
accompanies the software.
all-guides.co
m
Keysight N432A Installation Guide
Auto IP mode
Use the following procedure if you require local PC control or you are working in
an isolated (non-site) LAN.
1
Connect the PC to the N432A.
2
Turn on the N432A.
3
Press
>
to access the Remote Interface display
(Figure 1-2). Ensure that AutoIP is selected.
4
Press
if you need to configure any optional settings.
5
Press
.
A pop-up message will appear for 5 seconds (Figure 1-3). Monitor the Status
at the bottom of the display to determine when the server has assigned an
address.
6
Press
to return to a measurement screen.
7
If you intend to program over the LAN interface, make sure that you have
installed the I/O software on your PC.
8
Use the Connection Expert utility of the IO Libraries Suite to add the N432A
and verify the connection.
9
You can use various programming environments to control the N432A. For an
overview on programming the N432A via LAN, refer to the connectivity guide
and the programming guide.
Remote Interfaces
Network AutoIP
Restart Network
NOTE
If you have installed other I/O software, refer to the documentation that
accompanies the software.
Keysight N432A Installation Guide
45
Static mode (configuring the LAN manually)
In static mode, you must set up the IP address, subnet mask, default gateway,
and DNS servers that are compatible with your network infrastructure. If they are
not set up correctly, the N432A will not be visible on your network.
1
Turn on the N432A.
2
Press
>
to access the Remote Interface display
(see Figure 1-2).
3
Press
to set the IP address and subnet mask. The default
gateway and DNS servers are optional settings.
To individually configure the settings, use the arrow keys, Select key, and
numeric keys to enter the required IP address, subnet mask, default gateway,
and DNS servers.
The values can range between 0.0.0.0 and 255.255.255.255.
Figure 1-4
LAN network manual setup
NOTE
If you configure an invalid IP address or an IP address that is used by another
device or host, an error message is generated. This error can be read by pressing
>
or sending the SYSTem:ERRor? query.
Error List
Remote Interfaces
Network Manual
Keysight N432A Installation Guide
4
Press
, to return to the Remote Interface display.
5
Press
.
A pop-up message will appear for 5 seconds (see Figure 1-3). Monitor the
Status at the bottom of the Remote Interface display to determine when the
server has assigned an address.
6
Press
, to return to a measurement screen.
7
If you intend to program over the LAN interface, make sure that you have
installed the I/O software on your PC.
8
Use the Connection Expert utility of the IO Libraries Suite to add the N432A
and verify the connection.
9
You can use various programming environments to control the N432A. For an
overview on programming the N432A via LAN, refer to the connectivity guide
or programming guide.
Configuring the LAN remotely
To automatically configure the LAN settings, enable the DHCP operation using
the SYSTem:COMMunicate:LAN:DHCP[:STATe] command.
To individually specify the settings, use the following commands:
–
SYSTem:COMMunicate:LAN:ADDRess
–
SYSTem:COMMunicate:LAN:SMASk
–
SYSTem:COMMunicate:LAN:DGATeway
–
SYSTem:COMMunicate:LAN:AIP[:STATe]
–
SYSTem:COMMunicate:LAN:RESTart
Restart Network
NOTE
If you have installed other I/O software, refer to the documentation that
accompanies the software.
Keysight N432A Installation Guide
47
GPIB
1
Install, or ensure that you have installed, the I/O software on your PC.
2
Follow your GPIB interface card vendor’s instructions for installing GPIB
hardware on your PC.
3
Connect a GPIB cable between your PC and the N432A.
4
Configure the installed GPIB card based on the vendor’s instructions.
5
Use the Connection Expert utility of the IO Libraries Suite to verify that the
N432A is displayed under the GPIB interface node.
6
You can use various programming environments to control the N432A. For
further information, refer to your GPIB card vendor’s guide.
Refer to the connectivity guide and the programming guide for an overview on
programming the N432A via GPIB.
Changing the GPIB address
The GPIB address is an integer between 0 and 30. The N432A is shipped with a
default address of 10. The GPIB address is stored in a non-volatile memory.
NOTE
If you have installed other I/O software, refer to the documentation that
accompanies the software.
NOTE
GPIB address 21 cannot be used as Keysight GPIB interface card default address
is 21. Other GPIB interface card may use a different integer as the default
address.
Keysight N432A Installation Guide
To change the GPIB address manually, proceed as follows:
1
Press
>
.
Figure 1-5
Changing the GPIB address
2
Use the arrow keys to highlight the GPIB Address entry field.
3
Press the Select key and use the numeric keys to enter the GPIB address in the
pop-up dialog.
4
Press Enter.
Changing the GPIB address remotely
You can set/query the GPIB address remotely using the following command:
SYSTem:COMMunicate:GPIB:ADDRess
Remote Interfaces
all-guides.co
m
Keysight N432A Installation Guide
49
Rack Mounting the N432A
Rack mounting information
Disconnect device requirements
During rack mounting, a disconnect device, for example, an IEC320 appliance
coupler, must be used. Consideration must be given to the following requirements
when installing the N432A in a rack:
–
An adequately rated switch (250 V, 10 A) or a circuit breaker (250 V,
5 A) shall be included in the rack.
–
It should be in close proximity to the N432A and within easy reach of the
operator.
–
It shall be marked as a disconnect device.
Ventilation requirements
When installing the N432A in a cabinet, the convection into and out of the N432A
must not be restricted. If the total power dissipated in the cabinet is greater than
800 W, then forced convection must be used.
Keysight N432A Installation Guide
Rack mounting a single N432A (using the Option 908 rack mount kit)
1
Remove the carrying handle.
2
Remove the front and rear rubber bumpers.
Keysight N432A Installation Guide
51
3
Fit the rack mount flanges.
(Parts available separately: 5063-9240)
4
Ready for installation.
Keysight N432A Installation Guide
Rack mounting two N432As together (using the Option 909 rack
mount kit)
1
Remove the carrying handle.
2
Remove the front and rear rubber bumpers.
Keysight N432A Installation Guide
53
3
The hardware below is required to link the N432As together.
4
Fit a small rack mount flange to the opposite sides of each N432A.
(Parts available separately: 5061-9694 and 5063-9212)
5
Fit two front linking plates to each N432A.
all-guides.co
m
Keysight N432A Installation Guide
6
Engage the linking plates at the front of the N432As.
7
Attach the rear linking brackets.
8
Ready for installation.
Keysight N432A Thermistor Power Meter
Installation Guide
55
2
Characteristics and
Specifications
For the characteristics and specifications of the N432A Thermistor Power Meter,
refer to the datasheet at
http://literature.cdn.keysight.com/litweb/pdf/5990-5740EN.pdf.
Characteristics and Specifications
56
Keysight N432A Installation Guide
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
This information is subject to change
without notice. Always refer to the
English version at the Keysight
website for the latest revision.
© Keysight Technologies 2010-2017
Edition 5, December 1, 2017
Printed in Malaysia
*N432A-90000*
N432A-90000
www.keysight.com