Inner Range 3000 Installation Manual

Specifications

Brand: Inner Range
Category: Security System
Model: 3000 (Installation Manual)
File Type: PDF
File Size: —
Pages: 20

Read Online

Read the Inner Range 3000 Installation Manual online using the built-in PDF viewer.

Text of the manual

Revision 4.02 June. 2000

1 Model 3OOO & ACCESS 4000 Control Module 995001 / 995002 INSTALLATION MANUAL SECURITY, ACCESS CONTROL & BUILDING AUTOMATION SYSTEM OVERVIEW The 3000/Access 4000 provides the next generation in Access Control, Security and Building Automation Systems. MODULAR DESIGN & EXPANDABILITY Modular hardware design provides the ability to adapt and expand a system to cater for virtually any configuration or application required - small or large. Large numbers of LCD Terminals, Input/Output Expanders and Access Control Modules can share a secure, monitored LAN system utilizing a fast, efficient communications format. Using the recommended cabling, modules on the LAN can be installed hundreds of metres from the Control Module. With the current range of modules available, this arrangement can provide over 2000 Zone inputs and over 2000 Auxiliaries on a single system. THE MODULES. The heart of the system is the Control Module. This unit stores all data, communicates with all other modules connected to the system LAN, and reports alarms and system activity to the Central Station via Dialer, Direct Line, GSM modem and other formats. To program and operate the system an Elite LCD Terminal or any of the PC based system management tools mentioned below are normally used. The LCD Terminal provides a 20 key backlit keypad, a backlit Liquid Crystal Display and connections for several Zone Inputs and Auxiliary outputs. Universal Zone Expanders are used to provide additional Inputs (16 or 32), Sirens and Auxiliary Outputs (8 to 32) in a system and can be installed remotely in suitable locations to greatly reduce the amount of cabling required to detectors and output devices. The Mini Expander Module provides low cost expansion when up to 8 Zones and Auxiliaries are required along with special event counting options (Event Counting available V3 or later). Door and Lift Access Modules are installed near the Door/s or in Lift Cars to provide Reader interfacing plus all the Inputs and outputs for complete monitoring and control of the Door/s and/or Lifts. The Analogue Module allows analogue values to be monitored and set points used for trigger control and/or report functions. SYSTEM MANAGEMENT. WDirect Upload/Download software is available for system Programming and Management, allowing the option of local or remote connection with operator password protection. Windows based system management software is also available incorporating dynamic graphics capabilities and sophisticated monitoring and report generation facilites. © 2000. Inner Range Pty. Ltd. Part No: 635001

MODEL 3000 / ACCESS 4000. CE Installation Notes.

2 Contents ELECTRICAL & MECHANICAL SPECIFICATIONS ...........................................................................................2 CONTROL MODULE PARTS LIST ........................................................................................................................3 INSTALLATION INSTRUCTIONS .........................................................................................................................4-5 WIRING DIAGRAMS ...............................................................................................................................................6-7 THE CONTROL MODULE PCB Link and Connector details.........................................................................................................................................8-9 Fault LED indications and LCD Terminal Error Messages .......................................................................................9 Control Module PCB layout .......................................................................................................................................10-11 LAN SYSTEM OVERVIEW .....................................................................................................................................12 Connecting Modules to the LAN ...............................................................................................................................12-13 System Earthing..........................................................................................................................................................12 Cable Types ................................................................................................................................................................14 System cabling configuration .....................................................................................................................................15 LAN Termination Details ...........................................................................................................................................15 Troubleshooting Flowchart ........................................................................................................................................16 & 17 LAN Voltage Testing .................................................................................................................................................18 SYSTEM OPTIONS. PIC Micro Options (U14) ......................................................................................................19 MENU FLOWCHART...............................................................................................................................................20 Electrical Specifications Power Supply Input: Transformer Input Voltage: 240V AC -10% / +10%. 50 Hertz. Transformer Output Voltage: 16.5V AC. 50 Hertz. Current Consumption: Maximum 500 milliAmps from 240V AC Source. Fuse Protection: Separate AC mains input fuse. 500 milliAmps. 8AG (25mm) PCB AC Input Voltage: 16 to 18V AC. 50 Hertz. Battery Capacity: 12V 6.5 AH. Sealed Lead Acid Battery. Battery Input Fuse: 5 Amperes. Power Supply Output: Current: Total combined current required by devices connected to LAN “POS” and “DET+” must not exceed 1.2 Amperes. Fuse Protection: Separate 2 Ampere fuses provided for: Siren1, Siren2, LAN Power & Detector Power. ALWAYS REPLACE FUSES WITH THE SAME FUSE TYPE AND VALUE! NOTE: See data supplied with detectors and output devices for actual current consumption of items connected to the module. Mechanical Specifications Dimensions: Length: 435 mm. Width: 320 mm. Depth: 112 mm. Weight: 9.5 kg. (Includes mains transformer, battery and cover)

Revision 4.02 June. 2000

3 Installing your Model 3000 / Access 4000 system. Control Module Parts List - Control Module PCB mounted on metal chassis in metal box. - Tamper switch bracket. - Telephone line cable. (Note: Non-standard configuration. Only suitable for use with this product) - Installation Kit containing: - 9 x plastic “D” bungs. Must be fitted to all unused cable entry cutouts in the cover. - 1 x Special AC Powercord entry “D” bung. - 6 x 8 Way plug-on screw terminals. - 8 x 2 Way plug-on screw terminals. - Tamper switch. - Tamper switch bracket. - Telecom Line cord. - 2 x 6.3mm Tamper switch connectors. - 2 x 4.8mm Battery terminal connectors. - 1 x 2 Amp M205 (20mm) Fuse. (Spare) - 20 x 2k2 End-of-line resistors. 16 x Zone Inputs, 4 x Spare. (red-red-black-brown-brown) - 20 x 6k8 End-of-line resistors. 16 x Zone Inputs, 4 x Spare. (blue-grey-black-brown-brown) - Spiral bound User Manual. - User’s Quick Reference Card. (4 page booklet) - Installation Manual. (This document) In countries where the Mains input cable is not pre-fitted, the following parts are also supplied: - 3 x Conductive Sleeves for AC Power cable termination. - 1 x Plastic Cable grommet. - Sufficient mounting screws to assemble all parts to housing.

MODEL 3000 / ACCESS 4000. CE Installation Notes.

4 Electrical AC Mains Power connection. In countries where the module is supplied without a mains power cord, a suitable mains power cord for connection to the 240V AC Mains supply must be installed by a suitably qualified electrician or technician. 1. Strip 30mm of the sheath from the end of the power cord. Trim 5mm from the ends of the Active and Neutral conductors so that the Earth conductor remains slightly longer. 2. Strip 5mm of insulation from each of the conductors and fit the conductive sleeves provided to the exposed ends of the conductors to protect the integrity of the wire strands. 3. Feed at least 150mm of the power cord through the AC mains cable entry hole from the rear (underside) of the chassis. 4. Terminate the power cord in the terminal and fuse block as illustrated in Diagram 1 below. (Note that the Active wire is always connected into the termination nearest to the fuse) 5. Determine the appropriate length of power cord between the terminal block and the cable entry hole. (Approx. 100mm) Working from the rear of the chassis, fit the plastic grommet (supplied) around the power cord and apply pressure to both sides of the grommet to clamp the cable. The grommet can now be inserted into the AC mains cable entry hole. 6. When fitting the cover, ensure that the special AC Powercord “D” bung is fitted to the cable entry cutout in the cover where the AC Powercord enters the enclosure. Standard “D” bungs must be fitted to all other unused cable entry cutouts. IMPORTANT NOTE: An AC Mains socket-outlet shall be installed near the equipment and shall be easily accessible for connection of the mains power cord. Mounting the Unit. See Diagram 2. 1. Installation environment should be maintained at a temperature of 0º to 40º Celsius and 15% to 85% Relative humidity (non- condensing) 2. CE Control Modules are supplied in metal enclosures which must be secured to a flat, vertical surface using fasteners through the four “keyhole” mounting holes in the chassis. 3. When mounting this product onto flammable surfaces, a fire protection backplate MUST BE INSTALLED. The mounting holes in the backplate align with the mounting holes in the chassis so no additional mounting hardware is required. Standard “D” Bungs must be fitted to all unused cable entry cutouts. This backplate is available from your distributor. Please quote part number 925010. 4. The tamper switch bracket must be positioned through one of the slots in either side of the chassis and under the base of the chassis, before the chassis is secured to the wall. Transformer input connection. Power Cord AC Mains cable entry hole & Plastic Grommet. Neutral Earth Active (Live) Fuse. 500mA 8AG (25mm) Diagram 1. 25mm INSTALLATION AND SAFETY INSTRUCTIONS Special “D” bung for AC Power cord entry.

Revision 4.02 June. 2000

5 Battery connections 16.5V AC Power connections to PCB. Transformer output terminal block. Tamper switch & bracket AC Mains Transformer Mounting Holes (x 4). Terminal block and fuse. AC Mains Input. 12V, 6.5AH Battery Fitting the Cover. In order to comply with regulations, all twelve (12) of the screws provided to fix the cover to the chassis must be tightly secured. Three screws are located on each of the long sides, and at each end of the top of the cover as illustrated in Diagram 3 opposite. Fire Protection Backplate option. (Side View) 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 Mounting Surface. Diagram 2. Diagram 3. UP 5. Orientation of the enclosure MUST be as per either of the illustrations in Diagram 2. Connecting Power to the PCB. See Diagram 2 below. 1. Measure and cut two appropriate lengths of insulated cable to connect between the AC mains transformer output terminal block (A) and the “AC” Input connections on the PCB (B). 2. Strip 5mm of insulation from both ends of the cables and terminate into the transformer output terminal block and then into the “AC” Input connections on the PCB. The cables may be routed underneath the chassis to avoid interference with other cables. Connecting the Battery to the PCB. See Diagram 2 below. 1. Measure and cut two appropriate lengths of insulated cable to connect between the “+B” and “-B” connections on the PCB (C) and the Battery terminals (D). 2. Strip 5mm of insulation from both ends of the cables and terminate one end into the “+B” and “-B” connections on the PCB. IMPORTANT NOTE: There are two terminals provided for each of the “+B” and “-B” connections. Ensure that each cable is connected to the correct terminal to avoid creating a short circuit across the Battery. 3. Terminate the other end of the cables into the 4.8mm Battery Terminal connectors supplied in the installation kit. The cables may be routed underneath the chassis to avoid interference with other cables. A B C D Top

MODEL 3000 / ACCESS 4000. CE Installation Notes.

6 604 Socket for 3000/4000 connection Exchange Line OR Leased Line 604 Cable from 3000/4000 (Supplied) 604 Socket to other equipment. DIALER LINE ONLY ZONE INPUT WIRING Typical Detection devices with Normally Closed Alarm contacts and Normally Closed OR Normally Open Tamper Contacts are wired as follows: Detection devices with Normally Open Alarm contacts are wired in exactly the same manner as above. When programming the Zone Input, however, the option to “Swap Seal and Alarm conditions” must be set to [Y]es. E01:Z01 X S R A N T . . Options -> n Y n n n n n n INPUT STATES: 2k2 = Sealed 9k (2k2 + 6k8) = Unsealed (or Alarm) Open Circuit = Tamper Short Circuit = Tamper Z1 Z2 Z3 2k2 6k8 Norm. Closed A larm Contact Norm . Closed Tam per Contact Norm. O pen Tam per Contact Wiring Diagrams Dialer Line Phone Line IN: Pins 2 & 6 Phone Line OUT: Pins 1 & 5 Direct Line For Direct Line formats (e.g. EarthNet), the Leased Line connects to Pins 2 & 6. e.g. TELECOMMUNICATIONS WIRING Mode 3 wiring diagram for Dialer reporting formats. (e.g. Contact ID, 4+2, IRfast, etc.) T11 or JP9 3000 / 4000 Control Module 1 2 3 4 1 2 5 6 1 2 3 4 1 2 3 4 5 6 5 6 1 2 5 6 3 4 T11 or JP9 3000 / 4000 Control Module 1 2 3 4 1 2 5 6 To Exchange Line OR Leased Line Connection to other equipment. DIALER LINE ONLY Other equipment such as a telephone, fax machine or answering machine may share the Dialer line connection. If so, the telecom connection must be wired as shown to ensure that the system has priority use of the line so that alarm reporting is not compromised. “604” Plug & socket wiring. (Australia Only) NOTE: Cable supplied is a non-standard configuration and is only suitable for use with this product.

Revision 4.02 June. 2000

7 SIREN WIRING Maximum of two 8 Ohm Siren speakers may be connected to each siren driver, wired in parallel. Norm. Closed Siren cover Tampers may be wired in series with the speaker cable. This method utilizes the siren speaker circuit monitoring. AUXILIARY WIRING Rules for Auxiliary wiring on any module in the 3000/Access 4000 system. - Auxiliaries 1 & 2 on the Control Module & Expander Modules can switch up to 500mA continuous and are suitable for inductive loads provided that a clamp diode is fitted across the load as shown below. - Max current on any other individual Auxiliary must be less than 200mA. - On any module with Plug pack; Auxiliaries + LAN current + Detectors must be less than 700mA, or an external power supply should be used. - The Positive of the device must be wired to the Positive connection nearest the Auxiliary. i.e. On the same module. - If an external power supply is used to power the device, a good common Negative connection MUST exist between the power supply and the module. - Clamp diode should be fitted across inductive loads. Cathode (bar) to +ve. Locks are activated via a relay. External power supply is used for lock power to prevent voltage spikes reaching the Concept equipment, provide longer battery backup & minimise the possibility of earth loops. N O T E : A uxiliary C urrent < 200m A per A uxiliary. +Ve connections to D E T + ve nearest the A ux. output N ote L E D orientation. 1k2 1.2 kΩ current lim it resistor. See notes. A X 2 A X1 S2 S1 + + R elay and L ock pow er C onnections M U ST be separated. C lam p D iode M U ST be fitted across L ock. C athode to + ve. o o POS NEG - + External Pwr Supply (Battery backed) LockLo ck Lock L ock. AX 2 A X 1 S2 S1 + + (N orm ally C lo sed) Siren cover tam per W h en w iring 2 sp eakers in parallel it is best to w ire the cover tam pers to zone inputs & pro gram for tam per pro cessing. (N orm ally C lo sed) Siren cover tam pers C A B LE: 1 4/0.2 M in im u m AX 2 A X 1 S2 S1 + +

MODEL 3000 / ACCESS 4000. CE Installation Notes.

8 LINKS. See pages 10 & 11 for location. LK1 Telecom Country Selection. Removed: Europe TBR21 Fitted: Australia / New Zealand. LK2 Memory chip (RAM) size select. 1-2 128k DS1245Y (32 Pin) or 512k DS1247Y (32 Pin) 2-3 32k DS1230Y (28 Pin) LK3 Installer Code Default. Disconnect AC and Battery from Control Module; Short LK3 Pins; Reconnect power, then remove the short. Installer code will be defaulted to “01”. LK4 RAM Initialize. (“Continue”). Used when required to rectify Memory problems. CAUTION! Will erase all programming if shorted to initialise memory. LK6 Microprocessor select. Factory use only. Removed (Normal): Standard Micro. Fitted: Micro Type 1 or 2. LK8 EPROM type selection. Factory use only. 1-2 Flash. 3-4 4 MBit EPROM. 5-6 2 MBit EPROM. See page 11 for diagrams. LK9 EPROM configuration. Factory use only. 1-2 Flash. 2-3 EPROM. LK10 LAN Termination. No Link. Unterminated. Link not fitted unless unit is first or last module on the LAN system. Link IN. Terminated. Link fitted when unit IS the first or last module on the LAN system. (See “LAN SYSTEM” details beginning on page 12 of this manual for more information) LK12 PSTN / Direct Line selection. LK13 Both links 1-2 PSTN (Dialler formats: IRfast, Contact ID, etc.) Both links 2-3 Direct Line (e.g. EarthNet) JP5 Regulated Power Supply Current Limit setting. Not Shorted 1.0 Amp. Normal setting for 6.5 to 7.0 AmpHour Battery. Shorted 3.0 Amp. Setting for 15 to 17 AmpHour Battery. TERMINALS. See pages 10 & 11 for location. T1-4 Zone Input connections. See Zone Input Wiring on page 6. T5 LAN connections. See “LAN SYSTEM” details beginning on page 12 for details. T6 Auxiliary outputs and Siren Outputs. See “SIREN WIRING” & “AUXILIARY WIRING” on page 7 for details. T7 Battery connection. T8 Detector Power. 12V Supply for Detectors and Auxiliary Devices. Total current sourced from “DET+” and “LAN POS” must not exceed 1.2 Amps. T9 16 to 18 V AC Input to PCB. (From Transformer Secondary winding) T10 Tamper Switch Input. Tamper switch supplied. No End-of-line resistors necessary. T11 Telecom connection Terminal block. Alternate connection for Dialer line or Direct line connection. Pins 2 & 4: Line In. Connection to Exchange line or Leased line. Pins 1 & 3: Line Out. Connection to other equipment sharing the Exchange line. See drawings on page 6.

Revision 4.02 June. 2000

9 CONTROL MODULE FAULT LEDs. See pages 10 & 11 for location. LED1 LED2 EXPLANATION / REMEDY ON OFF Ram Fault. RAM faulty, in backwards, out by one pin or LK2 not correct. Power off, fit correctly or replace. OFF ON Non-volatile RAM not initialised. Short LK4 to continue. (Erases all programming) ON ON Configuration Problem. Return options memory chip to Distributor. Fast Flash OFF Hardware Problem. (EEPROM) Return unit for service. OFF Fast Flash Wrong GAL for NVRAM size. (Illegal Memory size) Contact the Distributor. Fast Flash Fast Flash Wrong GAL for required options. (Illegal option/s) Contact the Distributor. Fast Flash ON Faulty Program chip. (EPROM) Return unit for service. ON Fast Flash Default of installer code not allowed. Contact Installer or return to Distributor for defaulting. Short LK4 or remove and reconnect power to the Control Module to continue with normal operation. Slow Flash OFF PIC not communicating. Return unit for service. OFF Slow Flash Incorrect Micro. Contact the Distributor. Slow Flash Slow Flash Secure Micro Version wrong. Contact the Distributor. Slow Flash ON Lock bits not set. Contact the Distributor. ON Slow Flash Configuration Version problem. Contact the Distributor. EXPANDER / READER MODULE FAULT LEDs RX TX EXPLANATION / REMEDY ON ON Module is un-addressed. OFF ON Module type unknown. Firmware upgrade required to Control Module. Flash ON Duplicate Module. This module number is already in use by a module of the same type. Flash Flash Module number selected is too big for Control Module RAM size. Select a lower Module number. ON OFF Too many modules on Network for Control Module RAM size. LCD TERMINAL ERROR MESSAGES MESSAGE EXPLANATION / REMEDY No Rx Terminal requesting address from Control Module, but no reply being received. Can’t Tx Terminal cannot send data because LAN is being held in “start” condition. Check for A/B reversed. Exists Module number selected already being used by another LCD Terminal. Choose another number. Too Big Module number selected is too big for Control Module RAM size. Select a lower Module number. Too Many Too many modules on Network for Control Module RAM size. HEADERS. See pages 10 & 11 for location. JP1 Port 0 connection. TEMPORARY connection of a PC for Upload/Download programming is allowed using the “Port 0 Interface cable” (993030). This Port shares the on-board modem with the Line interface and therefore MUST NOT be used as a permanent connection. JP2 UART Serial Port Board. A UART Board and appropriate cable/s must be fitted if Printer, PC, GSM modem, External modem or Securitel Interface etc. is being used. JP3 Auxiliary Expansion Port. For 8 Auxiliary Expansion board. P/N: 995055. JP4 Auxiliary LAN connection. An LCD Terminal can be connected to this Header if required for diagnostic purposes. A cable is available (P/N: 993028) with matching header socket and flying leads. JP6 Fibre Optic Port. For future applications. JP7 Not currently used. JP9 Telecom socket. See drawings on page 6.

MODEL 3000 / ACCESS 4000. CE Installation Notes.

10 THE CONTROL LK12 & LK13 PSTN (Dialer) Both 1-2. Direct Line Both 2-3. JP5 Regulated P.S. Current Limit. T1 to T4. Zone Inputs. See “ZONE INPUT WIRING” on p6 for details. JP9 Mode 3 Line Socket for connection to Telecom Line. (Cable supplied) JP1 Port 0. Temporary PC connection via Port 0 interface cable. LK8 EPROM Type selection. LK9 EPROM Configuration. LK1 Telecom Country selection. LED12 AC Supply present. LED17 On = Battery Charge relay On. (Battery supply above 12.7V) T11 Alternate Telecom Line connection. LED 2 to LED 6 Telecom/Port 0 Status LEDs. LED 2. On = Line Seize Relay Active. LED 3. On = Dial Indicator. LED 4. On = Ring Voltage Indicator. LED 5. On = Telecom/Port 0 Transmit Data. LED 6. On = Telecom/Port 0 Receive Data. JP2 Expansion Port UART Interface connection. T7 & T9 16V AC Input & Battery connections. IN 2 & 4 OUT 1 & 3

Revision 4.02 June. 2000

11 L MODULE PCB LED13 & LED14 (L1 & L2) FAULT LED DIAGNOSTICS See table on page 9. LK10 LAN Termination. F2, F3 & F5 Fuses for Siren 1, Siren 2 & Detector Power. 2 Amp. M205. LED15 & LED 16 (RX & TX) LAN Activity LEDs Rx =Receive Data Tx =Send Data T10 Cabinet Tamper input. T8 Detector Power connections. LK2 Memory chip (RAM) size select. 2-3 28 Pin (32k) 1-2 32 Pin (128k & 512k) JUMPER LINK ORIENTATION 1 • 1 • • 2 2 • 1 2 3 3 • • 4 3 • • • • 5 • • 6 LK3 Installer Code Default LK4 Initilize RAM (Continue). CAUTION. LK6 Microprocessor select. F4 LAN “POS” Fuse. 2Amp. M205. T6 Auxiliary outputs & Siren outputs. T5 LAN connections. JP6 Fibre Optic Port. For future applications. JP4 Auxiliary LAN connection. For temporary connection of LCD Terminal for diagnostic purposes. LED 11. On = 13V Supply present LED 10. On = 5V Supply present. U14. JP3 Auxiliary Output Expansion Port.

MODEL 3000 / ACCESS 4000. CE Installation Notes.

12 CONNECTING MODULES TO THE LAN. Refer to diagram opposite. - “A” & “B” signal connections are wired in parallel across the system using TWISTED PAIR cable. ¶ See “Cable Types” details on page 12. The “NEG” connection (0V reference) must also be wired to every module. · - An optional + 12 V connection (LAN +ve) may be used to provide power to modules that do not have their own on-board power supply. e.g. LCD Terminals. ¸ - The + 12 V connection (LAN +ve) used to power LCD Terminals, etc. can be derived from any module with it’s own on- board power supply (Control Module and Expander Modules), or from a separate external power supply. ¹ CAUTION ! Never connect the +ve (POS) of two power supply sources together. i.e. Control Module LAN POS, Expander Module LAN POS, or External Power Supply +ve. This is one of the reasons that “SPARE” wiring terminals are provided on most types of modules. - When wiring the LAN to modules that are powered from their own on-board power supply (e.g. Zone Expanders), use the “Spare” terminal (labelled “SPARE” or “SPR”) for the LAN +ve connection. º NOTE: LAN “POS” and “NEG” should not be used to power detectors, relays, etc. Always use “DET+” and “DET-” on the module to power these devices. - When wiring the LAN to modules that are powered from an external Power Supply (e.g. Reader Modules), use the “Spare” terminal (labelled “SPARE” or “SPR”) for the LAN +ve connection. » - A DC Voltmeter may be used to check that the LAN will operate reliably. See “LAN Voltage Testing” on Page 18. LAN SYSTEM OVERVIEW The 3000/Access 4000 LAN (Local Area Network) is a 3 or 4 wire network used to connect the modules in a system. Up to 250 modules can be connected on the LAN system, comprising up to 99 modules of any particular type. (Depending on Memory size & configuration) Using recommended cable types, modules on the LAN can be installed hundreds of metres from the Control Module. Data encryption ensures secure LAN communications at all times, while the programmable supervisory polling system continuously monitors the network to detect cable tamper, cable fault conditions, module off-line and module substitution. The data format used in the 3000/Access 4000 LAN has been developed to ensure fast, reliable communications regardless of the size of the system. For larger systems and complex sites, LAN Isolators can provide opto-isolation between sections of the LAN, eliminate potential earth loop problems, improve surge protection, provide signal level restoral for improved performance over longer cabling distances and offer a monitored “loop” LAN wiring option for a higher level of LAN integrity. SYSTEM EARTHING - The System Ground is connected to Mains Earth via the Power cord at the Control Module. The enclosure can be mounted on a grounded conductive surface, providing a secondary ground connection. - In some cases a Printer, PC, modem, etc. connected to the Control Module UART board may also provide a connection to earth via the peripheral device. If so, ensure that the peripheral device is powered from the same AC Mains circuit or the RS232 Serial connection is isolated. - The Intelligent 4 Door Access Module also has local Ground connected to Mains Earth via it’s Power cord, however, the System LAN connection (X1 “ISO LAN”) is isolated to eliminate Earth loops. Ensure that there are no other 0V or Ground connections between the Control Module and Intelligent 4 Door Access Modules. - While the metal chassis of Modules with on-board power supply such as Universal Expanders is connected to Mains Earth, the PCB circuitry is isolated from the chassis. Ensure that wiring, additional hardware or peripherals connected to these modules does NOT provide an Earth connection to the Module PCB. - Ensure that all other Modules (with no on-board Power supply) have NO local connection to Earth.

Revision 4.02 June. 2000

13 POS NEG A B SPR SPR TAM TAM CONTROL MODULE EXPANDER MODULE - LAN “+ve” wired to “SPR” (Spare). 1 or 2 DOOR ACCESS MODULE - Powered from LAN. EXPANDER MODULE - LAN +ve wired to “SPR” (Spare). - “POS” used as LAN +ve supply source. LAN B LAN A GND +VE X01 X02 X03/Z01 X04/Z02 TAMPER GND EXT PWR SPARE B A GND +VE POS NEG A B SPR SPR TAM TAM EXTERNAL POWER SUPPLY +12V -VE 1 or 2 DOOR ACCESS MODULE - Powered from external Power supply (LAN “+ve” connected to “SPARE”) ELITE LCD TERMINAL ¶ · ¸ ¹ º Connecting Modules to the LAN. » º ¹ POS NEG A B +VE GND A B SPARE EXT PWR GND TAMPR

MODEL 3000 / ACCESS 4000. CE Installation Notes.

14 CABLE TYPES - TWISTED PAIR Cable MUST be used to connect the LAN. Multi-strand wire is preferred for terminating into the screw terminal connectors. Two pair Telephone or LAN cable is suitable as it provides all 4 conductors required. One pair for “A” & “B”, and the other for “POS” & “NEG”. Unshielded cable is quite acceptable, however, in situations where electrical storms or high levels of electrical interference are a problem, shielded 2 pair cable may be used. Examples of suitable 2 pair cables: Unshielded. Figure 1. Shielded (All Multistrand) Figure 2. Olex TJC590AA002 Olex JEIP87AA002 Belden 8723 * † 3 Pair. Tycab TIC6105 † Tycab DPF4702 Tycab DQQ47025 * ‡ Multistrand (7/0.2). MM MegaTwistpatch ‡ MM B2002CS Garland MCP-2S * Indivually screened pairs. Category 5. Electra EAS7202P / 7302P Electra EAS16202P - If SHIELDED CABLE is used, DO NOT use the shield as a negative connection & do not allow the shield to make contact with Negative, Ground, or any other wiring or metalwork within the system. Shields should only be terminated to a Protective Earth at ONE END of the cable. ¶ See “System Earthing” below. If no suitable earth point is available at a module location, the shield can be looped back to the shield of the previous length of cable. · - LAN POWER CABLING. Separate heavy duty Figure 8 cable ( 24 / 0.20 recommended) should also be run for “POS” & “NEG” over longer distances if used for powering modules. e.g. LCD Terminals. Figure 3. LAN “POS” current required: Max. Cabling Length for LAN +ve (POS) & GND (NEG) Twisted pair Fig 8. 14 / 0.20 Fig 8. 24 / 0.20 60mA (e.g. 1 LCD Terminal) 200 metres 400m 640m 120mA (e.g. 2 LCD Terminals) 100 metres 200m 320m 180mA (e.g. 1 Reader Module - Reader pwr not incl) 62metres 130m 210m 250mA (e.g. 4 LCD Terminals) 50 metres 100m 160m 500mA (e.g. 8 LCD Terminals) 25 metres 50m 76m Remember to allow for any extra current required by Detectors, Auxiliaries, Readers, etc: NOTE: Lock strikes must not be powered from the LAN. Relay (1A contacts) approx. 25mA Small Proximity reader (~10cm read range) ~50 to 120mA Relay (5A contacts) approx. 45mA Standard Prox reader (~15cm read range) ~120 to 180mA PIR 15 to 25mA typical. Magnetic Swipe reader. ~15mA Figure 1. Twisted pair communications cable. Figure 2. Shielded, twisted pair communications cable Figure 3. Heavy duty Figure 8 cable. 24 / 0.20 Used for LAN +ve & GND on long cable runs. SURGE PROTECTION. - In multi-building installations and on longer cable runs, shielded cable may be used to provide added protection against voltage surges. - Each individual shield should be terminated to a Protective Earth point such as an earth stake, building earth (metal building framework) or water pipe. ¶ It is very important to ensure that the shield makes no contact with Negative, Ground or any other wiring within the system. - LAN Isolator/s can also be included in a Surge protection scheme to electrically isolate different sections of the LAN at the point where LAN cabling enters/exits each building, or on cable runs that are more exposed to voltage spikes or surges.

Revision 4.02 June. 2000

15 EXPANDER MODULE T CONTROL MODULE LCD TERMINAL LCD TERMINAL T READER MODULE 2000 metres max. 1500 metres max. · » » EXPANDER MODULE CONTROL MODULE T LCD TERMINAL LCD TERMINAL READER MODULE Total LAN cable in this section < 2000m (1955 m) ¸ º T T 400 m. 350 m. 500 m. 5 m. LCD TERMINAL 100 m. 300 m. LCD TERMINAL 300 m. ¹ » » ¹ LCD TERMINAL READER MODULE 500 m. 600 m. READER MODULE T 400 m. LAN2 LAN3 LAN1 LAN Isolator » EXPANDER MODULE T ¼ LCD TERMINAL READER MODULE T ¼ 600 m. 150 m. 500 m. Figure 4. Simple LAN configuration. Figure 5. Complex LAN configuration. ¶ ¸ SYSTEM CABLING CONFIGURATION Figure 4 & Figure 5. - Avoid installing the LAN cable with mains power cables & any other cables likely to cause interference wherever possible - No module is to be more than 1.5km (1500 metres) cable length from the Control Module OR from a LAN Isolator “LAN 2” or “LAN 3” Port. ¸ (LAN Isolator/s can be used to extend the maximum cabling distance) - TOTAL LAN CABLING in a system without LAN Isolators should not exceed 2000 metres, and/or 64 Modules. ¹ If the total amount of LAN cable will exceed 2000 metres, and/or there are more than 64 modules to be connected, LAN Isolator/s must be used to separate the LAN system into sections and maintain optimum LAN performance. i.e. Include one LAN Isolator for every 2000 metres of LAN cabling and/or for every 64 Modules connected. º LAN TERMINATION Figure 4 & Figure 5. - The LAN MUST be Terminated for optimum performance, by ensuring that the Termination Resistor (470 Ohm*) is “IN” on the first and last modules in the LAN network. Terminated modules are indicated with a “T” on the illustrations. » (Termination is put “IN” with a jumper link or a DIPswitch, depending on the module type) * See Note 1 on Page 15. - MULTIPLE CABLE RUNS. In systems where there are multiple cabling runs going out from the Control Module or LAN Isolator (i.e. “star” configuration), Termination is fitted on the modules at the end of the two longest runs. ¼ 1500m. from “LAN3” »

MODEL 3000 / ACCESS 4000. CE Installation Notes.

16 LAN TROUBLESHOOTING FLOWCHART BEFORE SYSTEM POWER UP (No Power connected to modules AND No batteries connected) A1. WHERE POSSIBLE, PHYSICALLY CHECK: -LAN A & B connections not reversed on any module. -No modules connected to earth. (via mounting bolts, ext. power supplies, input/output cabling, etc.) Note that the Control Module may be connected to earth via external equipment connections. i.e. Printer, PC, modem, etc. If so, this must be the only earth connection in the system. -Only two modules in the system are terminated. ⇓ A2. CHECK FOR SHORT CIRCUITS ON THE LAN (No Power connected AND No batteries connected) METER ON OHMS RANGE Check at the Control Module for short circuits between: -LAN A & B. -LAN A to +ve and -ve. -LAN B to +ve and -ve. Note:DC Resistance in the LAN cable (~0.18Ohms/metre) can mask short circuits that exist on longer cable runs. ⇓ A3. CHECK FOR CORRECT LAN TERMINATION (No Power connected AND No batteries connected) METER ON OHMS RANGE Measure between LAN A & LAN B on the Control Module: 170 to 300 Ohm.* OK. (System with up to 32 modules) 140 to 270 Ohm.* OK. (System with up to 64 modules) Lower value. More than two modules terminated or Short cct across LAN A & LAN B. Higher value. Less than two modules terminated or Open cct on LAN A &/or B wiring. * See Notes 1 & 2. ⇓ POWER UP SYSTEM & CONNECT BATTERIES A4. CHECK CONTROL MODULE OPERATION DC POWER CHECK. With Meter on DC Volts range, measure between LAN +VE & LAN -VE (GND) on the Control Module: 11V to 14V. OK. <11V. Too many devices being powered from the Control Module or Battery Flat. Check FAULT LEDs on Control Module: Both Off. OK. Proceed to step A5. Any other state. Refer to “Control Module Fault LEDs” table on Page 9. ⇓ A5. DETERMINE THE TYPE OF LAN PROBLEM A. SOME MODULES HAVE INTERMITTENT COMMUNICATIONS PROBLEM. Proceed to Step B1, “Intermittent LAN problems”. ⇒ B. SOME/ALL MODULES NOT COMMUNICATING AT ALL. Proceed to Step A6. ⇓ A6. IS THE LAN COMPLETELY DEAD ? YES. Proceed to Step C1, “LAN Dead”. ⇒ ⇒ NO. (Some Modules not communicating, others OK) Proceed to Step A7. ⇓ A7. CHECK STATUS OF PROBLEM MODULE/S DC POWER CHECK. Meter on DC Volts range. Check for 11 to 14 Volts between LAN +VE & LAN -VE (GND) on the problem module. See Note 3. Check FAULT LEDs (TX & RX LEDs) OR LCD Display on problem Module: Both LEDs Off OR Display has no “Module ...” messages. Proceed to step A8. Any other state. Refer to “Expander/Reader Module Fault LEDs” table or “LCD Terminal Error messages” table on Page 9. ⇓ A8. TEST LAN VOLTAGES AT PROBLEM MODULE/S Perform LAN Voltage Checks at the problem Module/s. Refer to the table “LAN Voltage Testing” on Page 16. ⇓ A9. SUBSTITUTE MODULE/S If the troubleshooting procedure fails to locate any power, wiring or termination problems, you may have an equipment fault. Replace the module/s suspected of causing the problem.

Revision 4.02 June. 2000

17 INTERMITTENT LAN PROBLEMS B1. WHICH MODULES ARE INTERMITTENT ? Using an LCD Terminal or Review Logging via Upload/ Download software, check Review Data for “Module Lost” and “Module Found” messages. Each message will also identify the Module type and number. Note the problem module/s. Proceed to Step B2. ⇓ B2. IS ANOTHER EVENT CAUSING THE MODULE TO BE LOST ? Look at the Review Messages immediately preceding the “Module Lost” messages for any event that repeatedly coincides with the loss of module/s, or if the loss of module/s occurs at, or around, the same time of day. Look for messages such as Door Un-lock/Lock, Siren On, Auxiliary On, etc., and note the times when the “Module Lost” messages occured. YES. Ancillary devices & external equipment (e.g. electrical machinery) can produce voltage spikes, electrical noise and excessive current drain. If the LAN, Power & Auxiliary circuits are not wired correctly or Earth loops exist, these devices can interfere with LAN communications. If such an event does coincide with loss of comms, reproduce the sequence of events to confirm the effect, then check any associated wiring circuits accordingly. NO. Proceed to Step A8 LAN DEAD ⇒ C1. TEST VOLTAGES AT CONTROL MODULE Perform LAN Voltage Checks at the Control Module. Refer to the table “LAN Voltage Testing” on Page 16. If this fails to locate the problem, proceed to Step C2. ⇓ C2. ISOLATE PROBLEM CABLING OR MODULE/S Disconnect all LAN wiring from Control Module. Reconnect one LCD Terminal and ensure that it communicates. (If it doesn’t, follow Steps A7 & A8) Reconnect the LAN one module at a time until a problem module, or section of cabling kills LAN communications when reconnected. With the problem area identified, proceed to Step A8. ⇓ 1. LAN TERMINATION CHECK Very early 3000 products (Australia & NZ only) had 120 Ohm Termination resistors which results in lower measurements (~70 to 140 Ohms). When expanding these systems, take termination OUT on the existing modules, and put termination IN on two of the new modules. Alternatively, take termination OUT on the existing modules and fit a 470 Ohm resistor between LAN A & B on those two modules instead. NOTE: This is only necessary if expanding the system, or if there are communication problems. If the system is operating reliably, no modification is necessary. 2. TERMINATION RESISTOR CHECK To determine if a module is fitted with a 120 Ohm or 470 Ohm Termination Resistor, ensure that TERM is “IN”, disconnect the module from the LAN, remove power, and measure across LAN A and B on the module with the meter on the OHMS range. 3. MODULE POWER TEST The Test Menu can be used to check LAN Power conditions. Logon to the LCD Terminal, then press , 4, 8. This activates the power test, and the results will be displayed on the LCD Terminal, and in the review memory. See “Concept 3000 Programmer’s manual” Rev 2.3 p154 for more information. NOTES: ⇒ ⇒ ⇒ ⇒ ⇒ ⇐ ⇐ ⇐ ⇐ ⇐ ⇐

MODEL 3000 / ACCESS 4000. CE Installation Notes.

18 LAN VOLTAGE TESTING NOTES: 1. These Voltage checks should be done with no (or minimal) communications traffic on the LAN. To ensure this: a) Check that poll times for all addressed modules in the system are set to the default 60 / 120 seconds or greater. b) Disconnect LAN A and LAN B from any unaddressed modules on the LAN, as these modules will be constantly attempting to send messages to the Control Module. c) Ensure that Terminals, Readers, etc. are not being used while performing tests. Before proceeding with Voltage tests, check the “RX” LED on the Control Module to confirm that there is minimal LAN activity. 2. To determine if a problem exists on the module under test, or elsewhere on the LAN, these voltage tests can be performed: a) With the module connected to the LAN. b) On the cable connections with the module disconnected from the LAN. t n io P ts e T E B O R P + t n io P ts e T E B O R P - D E T C E P X E T L U S E R / M E L B O R P Y D E M E R e v + N A L D N G r o e v - N A L C D V 4 1 ot V 1 1 . V 0 n e e w te b tc c tr o h s r o ,n oitc e n n o c e v + N A L tiu cric n e p O .e v - N A L d n a e v + N A L . V 1 1 < re w o p N A L e ht m o rf d ere w o p s elu d o m y n a m o o T .e cru o s ylp p u s e g atlo V e viss e c x e g nis u a c g nilb a c N A L f o )e g a u g r o ( htg n e L .elb a c e ht n o p o r d B N A L A N A L C D V m 0 0 4 ot 0 0 2 . V m 0 0 2 < . B & A N A L n e e w te b tc c tr o h S . N A L f o n oitc e s siht ni d eta ni m ret s elu d o m 2 n a ht er o M . V m 0 0 4 > .tiu cric n e p O B N A L r o/ & A N A L N A L f o n oitc e s siht ni d eta ni m ret s elu d o m 2 n a ht ss e L ) g n id a e r e vit a g e N ( V 0 < s n oitc e n n o c B N A L & A N A L . .d e sre v er A N A L D N G r o e v - N A L C D V 5.2 ot V m 0 0 2 . C D V 5.2 > / V m 0 0 2 < e n o n a ht er o m e v a h y a m m ets y S .s/p o ol htra e g nis u a c ,tnio p htra e n a ot d etc e n n o c elu d o m d etc e n n o c si m ets y s e ht ni elu d o m e n o n a ht er o m o n ta ht eru s n E htra e ot d etc e n n o c e b y a m elu d o m a ta ht re b m e m e R .htra e ot la n retx E ,retnir P , C P .g.e .g nilb a c s'ti r o e civ e d lare h pire p a aiv .cte ,e civ e d tu ptu O ,r otc ete D ,ylp p u s re w o p elpitlu m s e k a m n oitaru gifn o c m ets y s r o/ & s d o hte m n oitallats ni fI stnio p elb atiu s ta s/r otalo sI N A L llats ni ,elb a dio v a n u stnio p htra e s/n oitc e s d e htra e e ht etalo si ot m ets y s N A L e ht ni B N A L D N G r o e v - N A L C D V 5.2 ot V m 0 0 2 .e v o b a s A

Revision 4.02 June. 2000

19 Designed & manufactured in Australia. Disclaimer: 1. The manufacturer &/or it’s agents take no responsibility for any damage, financial loss or injury caused to any equipment, property or persons resulting from the correct or incorrect use of the system or it’s peripherals. The purchaser assumes all responsibility in the use of the system and it’s peripherals. 2. While every effort has been made to ensure the accuracy of this manual, the manufacturer assumes no responsibility or liability for any errors or omissions. Due to ongoing development, this manual is subject to change without notice. SYSTEM OPTIONS A special Options Micro chip is used to enable certain system options and upgrade options in the Control Module. The Chip is labelled U14 and is located between the Zone 9 to 16 Input connections and Links LK3 to LK6. See PCB layout on page 11. A range of standard Options Micro chips are available. These chips can be purchased and changed over by the installer at any time to provide additional features. The price of each Options Micro Chip Type will vary according to the feature/s that the chip will enable. NOTE: If the additional feature required is new and was not available in the version of firmware currently in the Control Module, then the Control Module firmware AND the Options Micro will need to be changed. When purchasing 128k or 512k Memory expansion for the Control Module, an Options Micro chip will also be supplied to enable the use of the additional memory. IMPORTANT NOTE: When purchasing Memory expansion you must specify which product is being upgraded. “3000” or “Access 4000”. The table below shows the current range of Options Micro chips available. This selection table may be expanded as further options become available. * Factory fitted option for Model 3000. (32k Memory) ^ Factory fitted option for Model Access 4000. (128k Memory) FEATURE OPTIONS MICRO TYPE AND DESCRIPTION 1* 2 3 4^ 5 Standard 3000 Standard 4000 32k 128k 512k 128k 512k Aircon. Control YES YES Door Interlocking YES YES ACCEPT YES YES YES YES YES High Level Lift I/F "Card only" Users YES YES GSM SMS YES YES YES YES YES Spare YES YES Lift Access Control YES YES 128k RAM YES YES 512k RAM YES YES