E-Stop Instruction Sheet

Emergency Stop Switch • P/N ESTOP IMPORTANT NOTE: Read and understand the instructions before installing, operating, or maintaining this equipment. This product is designed to be a component of a customized control system. It is the responsibility of each customer to ensure the correct overall functionality of its systems and machines. SCI, its subsidiaries and affiliates are not in a position to guarantee all of the characteristics of a given system or product not designed by SCI. Operation Emergency Stop Switches are mounted and used in line with the input power controlling an SCI safety tester. Its intended function is to avert harm or to reduce existing hazards to persons, machinery, or work in progress. The E-Stop should be triggered when an immediate hazardous situation occurs that needs to be ended or averted quickly in order to prevent injury or damage. To trigger E-Stop press down on mushroom cap, tthis will immediately cut power to the connected tester. To release the E-Stop rotate the cap clockwise. This will immediately close the connection and provide power to the connected tester. WARNING: Device under test may still be charged after E-Stop has been enabled. Take appropriate measure’s to discharge any devices which may hold capacitive charge. Installation guide Step 1 - When choosing a mounting position, consider your input power source i.e. nearest wall outlet and electrical instrument location. Use pre-drilled holes to mount the E-Stop enclosure to desired location. See page 3 for enclosure spacing and measurements. © 2020 Ikonix USA • 28105 North Keith Drive, Lake Forest, IL 60045 USA Page 1 • ESTOP-INST V1.01 | 7.2020 Step 2 - Connect female end of E-Stop to the tester you wish to control. Step 3 - Connect male end of E-Stop to input power. Maintenance Routinely verify functionality of switches and control circuits. Check for damage to push-button and enclosure.

E-Stop Instruction Sheet

Emergency Stop Switch MODEL E-Stop Push Button Switch Product Specs Rated Insulation Voltage Max 600V Rated Thermal Current Max 10A Dielectric Strength 2500VAC (1min) Insulation Resistance Insulation Resistance 100MΩ General Environment 32° F - 104° F (0° - 40° C) Dimension 145mm(L) × 80mm(W) x 60mm(H) Weight 1Kg STANDARDS Enclosure IP65 rated Contact Switch EN 60947-5-5/A1:2005 EN 60947-5-1/A1:2009 ANSI/UL 508 Specifications/Drawings 56mm 145mm 5mm Screw Hole Size 134mm 100mm 56mm © 2020 Ikonix USA • 28105 North Keith Drive, Lake Forest, IL 60045 USA Page 2 • ESTOP-INST V1.01 | 7.2020

Other Switch Manuals