HunterDouglas Luxaflex PowerView Reference Manual
Read Online
Read the HunterDouglas Luxaflex PowerView Reference Manual online using the built-in PDF viewer.
Text of the manual
PowerView® IRB Roller Blind Reference-guide
Congratulations with the purchase of a Luxaflex® PowerView® Roller blind. This guide helps you get started with your
Roller blind powered by an integrated Li-ion battery.
1. Delivery condition
1.1. Pebble® or wand remote / Scene controller or Hub are purchased seperately
Pebble remote
Scene controller
Hub
MANUAL
Page 1 of 23
version: 1.0
1.2. End limits factory set
2. Special to the Integrated Rechargeable Battery motor
2.1 First Use
When you will first use your motorized blind with integrated battery we advise to always first charge your blind. However
when you receive your blind, it is in a so called hibernation status. To wake it up and make it functional you will need to
plug in and pull out a USB type C charging connector into the charging port of your blind. from this point the motor will
start up and become useable in a few seconds.
The top limit is set to the maximum roll-up
position
The bottom limit is set to the ordered
product height
MANUAL
Page 2 of 23
version: 1.0
When charging your blind, the blind/motor needs to be in an awake state. To wake up the blind please perform the
following:
1. Manual motor Button
2. USB Type-C Charging port
3. LED status indicator
MANUAL
Page 3 of 23
version: 1.0
2.3 LED behaviour and sequences
2.2.1
Insert and extract USB type C charging plug. (like described at 2.1
First use)
2.2.2
Re-insert the USB -Type C connector to start charging.
2.2.3
The motor LED indicator will start blinking RED, signaling the
charging process is activated.
2.2.4
When the LED turns green the integrated battery is fully charged.
constant
CHARGE at very low voltage level
MANUAL
Page 4 of 23
version: 1.0
3. Getting started
3.1 Pairing a remote
A PowerView® remote can control up to 6 individual groups of blinds (buttons 1 to 6 at the top of the remote). The
instructions below assign the blind to group 1.
blinking
CHARGE (normal)
constant
Fully Charged
flashing
CHARGE not allowed (temperature to high)
Alternately
CHARGE NTC ERROR (open/short circuit)
3.1
Locate the manual control button on your blind.
3.2
Press and hold the stop button for 6 seconds.
Keep pressing until the remote lights start
blinking
MANUAL
Page 5 of 23
version: 1.0
Press the group1 button.
IMPORTANT
Watch out to perform steps 2.4 and 2.5 within 3 seconds!
3.4
Press and hold the manual control button .
3.5
Press the open button.
The blind will jog 1x
3.6
Release the manual control button .
MANUAL
Page 6 of 23
version: 1.0
4 Operating the blind
4.1. Selecting a blind
3.7
Press and hold the stop button for 6 seconds.
The remote will exit programming mode
automatically after 20 seconds.
Keep pressing until the remote lights stop
blinking
Select 1 blind only
Select 2 or more blinds
MANUAL
Page 7 of 23
version: 1.0
4.2. Open / close a blind
Select all blinds
A. Select blind group
B. Press open button
MANUAL
Page 8 of 23
version: 1.0
4.3. Move a blind to a favourite position
C. Press close button
A. Select blind group
B. Press favourite button
MANUAL
Page 9 of 23
version: 1.0
5. Set a favourite position
5.1
Select the blind channel
5.2
Use the open , stop and close buttons to
move the blind to the desired favourite position. Use
the arrow up and arrow down buttons to fine-
tune.
5.3
Press and hold the stop button for 6 seconds.
DO NOT select a group on the remote!
Keep pressing until the remote lights start
blinking
IMPORTANT
Watch out to perform steps 4.4 and 4.5 within 3 seconds!
MANUAL
Page 10 of 23
version: 1.0
Press and hold the manual control button .
5.5
Press the favourite button.
The blind will jog 1x to acknowledge the
favourite position is set
5.6
Release the manual control button .
5.7
The favourite position is set!
MANUAL
Page 11 of 23
version: 1.0
6. Adjusting the end limits
6.1. New Top limit
6.1.1
Press and hold the manual control button .
6.1.2
Press the open button.
Make sure group1 on the remote is selected.
The blind will jog 1x
6.1.3
Release the manual control button .
The motor LED turns red to acknowledge the
motor is in program mode
MANUAL
Page 12 of 23
version: 1.0
Use the open , stop and close buttons to
move the blind to the new top position. Use the
arrow up and arrow down buttons to fine-tune.
6.1.5
Press and hold the stop button for 6 seconds.
DO NOT select a group on the remote!
Keep pressing until the remote lights start
blinking
IMPORTANT
Watch out to perform steps 5.1.6 and 5.1.7 within 3 seconds!
6.1.6
Press and hold the manual control button .
MANUAL
Page 13 of 23
version: 1.0
Press the open button.
The blind will jog 1x to acknowledge the new
limit is set
6.1.8
Release the manual control button .
The motor LED turns off
6.1.9
Press and hold the stop button for 6 seconds.
The remote will exit programming mode
automatically after 20 seconds.
Keep pressing until the remote lights stop
blinking
MANUAL
Page 14 of 23
version: 1.0
6.2. New Bottom limit
6.1.10
The new top limit is set!
6.2.1
Press and hold the manual control button .
6.2.2
Press the close button.
Make sure group1 on the remote is selected.
The blind will jog 1x
MANUAL
Page 15 of 23
version: 1.0
Release the manual control button .
The motor LED turns red to acknowledge the
motor is in program mode
6.2.4
Use the open , stop and close buttons to
move the blind to the new bottom position. Use the
arrow up and arrow down buttons to fine-tune.
6.2.5
Press and hold the stop button for 6 seconds.
DO NOT select a group on the remote!
Keep pressing until the remote lights start
blinking
IMPORTANT
Watch out to perform steps 5.2.6 and 5.2.7 within 3 seconds!
MANUAL
Page 16 of 23
version: 1.0
Press and hold the manual control button .
6.2.7
Press the close button.
The blind will move to the top limit to
acknowledge the new bottom limit is set
6.2.8
Release the manual control button .
The motor LED turns off
6.2.9
Press and hold the stop button for 6 seconds.
The remote will exit programming mode
automatically after 20 seconds.
Keep pressing until the remote lights stop
blinking
MANUAL
Page 17 of 23
version: 1.0
7. Additional actions
7.1. End limits reset (factory default)
This procedure will erase all limits stored in the volatile motor memory. It will not clear the Network ID and Group
assignments.
6.2.10
The new bottom limit is set!
Note
This procedure can be skipped for a fresh out of the box motor.
The motor will jog 2x when receiving any PowerView® command (e.g. Pressing the manual control button on the motor),
to confirm no limits are set.
MANUAL
Page 18 of 23
version: 1.0
Remove (battery) power from the motor by inserting
the USB-C connector into the motor head.
7.1.2
Press and hold the manual control button on the
motor.
MANUAL
Page 19 of 23
version: 1.0
7.2. Network reset
This procedure will erase all network data stored in the motor, including Network ID and Group assignments. It will not
clear the end limits. Completing a Network reset will prevent a PowerView® remote or App from operating the window
covering until it is reprogrammed.
7.1.3
Apply power to the motor by disconnecting the USB-C
connector while press and hold the manual control
button .
the motor LED turns orange after power is
applied
7.1.4
Hold the manual control button until the motor
jogs 1x.
The end limits have been cleared and the motor will
re-boot.
MANUAL
Page 20 of 23
version: 1.0
8. Motor control button LED
The motor control button LED gives an indication of the motor status. The LED can flash RED, ORANGE or GREEN. Below
is the overview of all possible combinations.
7.2.1
Press and hold the manual control button on the
motor for 12 seconds .
The blind will jog 1x at 6 seconds and a
second time at 12 seconds
7.2.2
Release the manual control button after the
second jog.
The Network ID and Group assignments have been
cleared.
Sequence
Explanation
After power up
Restart / Start up
Blind type: Roller Blind
MANUAL
Page 21 of 23
version: 1.0
Blind type: Twist® Roller Blind
After reset
End limits reset (factory default), see chapter
7.1
Network reset on manual control button
release, see chapter 7.2. Blind type: Roller
blind
Network reset on manual control button
release, see chapter 7.2. Blind type: Twist®
Roller Blind
Others
The maximum motor current has been
reached. E.g. The blind is stuck at an
obstacle.
(Continuous)
Steady red LED. The motor is in program
mode.
MANUAL
Page 22 of 23
version: 1.0
Hunter Douglas Europe B.V. and its affiliates (Hunter Douglas) reserve the right to make corrections, enhancements, improvements and other changes to
its products and services, and to discontinue any product or service. Buyers should obtain the latest relevant information before placing orders and
should verify that such information is current and complete. All products (also referred to herein as "components") are sold subject to Hunter Douglas’
terms and conditions of sale supplied at the time of order acknowledgment. Hunter Douglas warrants performance of its components to the
specifications applicable at the time of sale, in accordance with its standard warranty terms. Testing and other quality control techniques are used to the
extent Hunter Douglas deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each
component is not necessarily performed. Hunter Douglas assumes no liability for applications assistance or the design of Buyers' products. Buyers are
responsible for their products, applications and interfaces using Hunter Douglas components. To minimize the risks associated with Buyers' products
and applications, Buyers should provide adequate design and operating safeguards. Hunter Douglas does not warrant or represent that any license,
either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination,
machine, or process in which Hunter Douglas components or services are used. Information published by Hunter Douglas regarding third-party products
or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a
license from a third party under the patents or other intellectual property of the third party, or a license from Hunter Douglas under the patents or other
intellectual property of Hunter Douglas. Reproduction of Hunter Douglas information in Hunter Douglas data sheets is permissible only if reproduction is
without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Hunter Douglas is not responsible or liable for
any altered documentation. Information of third parties may be subject to additional restrictions. Resale of Hunter Douglas components or services with
statements different from or beyond the parameters stated by Hunter Douglas for that component or service voids all express and any implied
warranties for the associated Hunter Douglas component or service and is an unfair and deceptive business practice. Hunter Douglas is not responsible
or liable for any such statements. Buyers acknowledge and agree that they are solely responsible for compliance with all legal, regulatory and safety-
related requirements concerning its products, and any use of Hunter Douglas components in its applications, notwithstanding any applications-related
information or support that may be provided by Hunter Douglas. Buyers represent and agree that they have all the necessary expertise to create and
implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures
that might cause harm and take appropriate remedial actions. Buyers fully indemnify Hunter Douglas and its representatives against any damages
arising out of the use of any Hunter Douglas components in safety-critical applications.
MANUAL
Page 23 of 23
version: 1.0