Harmopool Whirlpool Bath Pump:

ZFPX5200 -ZFPX5210 - ZFPX5220

Table of content

Safety instructions ................................................................................................................... 3 General information ................................................................................................................ 3 Installation ............................................................................................................................... 4 Assembly .................................................................................................................................. 4 Electricity ................................................................................................................................. 4 Controls prior to first start-up ................................................................................................. 5 Start-up .................................................................................................................................... 5 Maintenance ............................................................................................................................ 5 FAQ .......................................................................................................................................... 6 Appendices .............................................................................................................................. 7

When installing and using this electrical equipment, basic safety precautions should always

be followed, including the following: ○ READ THE MANUAL AND FOLLOW THE INSTRUCTIONS ○ In order to reduce the risk of injuries, children are not allowed to use the device without strict supervision. ○ Risks of Electrical Shock . Connect only to grounding type receptacle protected by a ground fault circuit interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by GFCI. ○ Do not bury the cord . Locate cord to minimize damages caused by lawnmowers, hedge trimmers, and other equipment. ○ In order to prevent injuries due to the running parts, do not make the electric pump running before the pipeline has been connected. ○ To reduce the risk of electrical shock, replace damaged cords immediately. ○ To reduce the risk of electrical shock, do not use the extension cord to connect unit electric supply; provide a properly located outlet. ○ This pump can only be used for fix-installed bath tub, it is not suitable for swimming pool spa. ○ Do not install within an outer enclosure or beneath the skirt of a hot tub unless it has been marked. ○ This appliance is not intended to be used by young children or infirm persons unless they are being adequately supervised by a responsible person which can ensure their safety. ○ Young children are not allowed to play with the appliance. ○ FOR INDOOR USE ONLY. ○ KEEP THESE INSTRUCTIONS General information ○ These are single - stage centrifugal pumps designed to operate with compact hydro massage equipment. They are equipped with an emptying system to prevent the discharge of residual liquid in the stoppings. ○ V/Hz esp.: See pump name plate. ○ The units are designed to operate with clean water at a maximum water temperature of 50O Celsius. ○ Storage temperature: -10O C ~ +50OC. Relative Air Humidity: 95% Max. ○ Made from top quality materials: the pumps are subjected to strict hydraulic and electrical controls and are carefully verified. ○ Correct installation is ensured by following the instructions; Over loads may be produced in the motor when the instructions are not being followed. We decline responsibility for any damage caused by not following these instructions.

○ The pump should be located in an area with good ventilation. Dimensions and position

of the pump for supporting and fixing the pump within this space can be found on Figure 2. ○ Pump must be fixed by screws on the tub shelf, and fixed with silent block to lower the noise and liberation. Sticking and enlacing is forbidden. ○ The pump will be getting hot whilst operating , the minimum distance between the motor of the pump and the surrounding structure should not be less then 20mm to ensure the device will cool down. ○ The suction pipe of the pump should be as short as possible. ○ The rating label should be visible after installation. ○ Parts containing electricity, except parts supplied with an extra low voltage <12V, must be inaccessible to the person in the bath. ○ Class I appliances must be permanently connected to fixed wiring. Parts including electrical components, except remote control devices, must be located or fixed so that they cannot touch the water. Assembly ○ The maximum inlet water pressure is smaller or equal to 0.15MPa. ○ The suction pipes should have a diameter equal to or larger than the discharge pipes. This can avoid the heat loss and improve the efficiency. ○ The suction and discharge pipes should not rest on the pump. ○ Seal all the connectors and unions well. Avoid any dripping on the motor. This can unfailingly damage it. ○ Use the hose module which supplements along with the bathtub, the old hose module cannot be reused. Electricity ○ The electrical install action should have a multiple separation system with contact openings of at least 3mm. ○ For protection against possible electric shock this unit must be mounted to the base in accordance with the installation instructions. ○ The protection of the system should be based on a residual current device (RCD) with a rated tripping current not exceeding 30mA. The supply cable should comply with EMC standards. ○ Single-phase motors have built-in thermal protection. ○ The electric connection must be carried out by qualified staff following th "EN60335-2- 60" standard strictly. ○ Please ensure that the earth cable connection is correctly made. ○ Wires serving as equipotential bonding conductors must have a cross sectional area between 2.5 mm2 and 6 mm2 and must be equipped with the terminal suitable receptacle.

Controls prior to first start-up

1. Verify that the pump shaft turns freely. 2. Check whether the voltage and frequency are according to the name plate. 3. The Hydro massage assembly should be equipped with a system to prevent the pump from starting up if a minimum water level is not present. 4. Check the rotating direction of the motor. This should correspond with the direction indicated on the fan cover. 5. If the motor does not start up, try to locate the problem in the table of most common faults and their possible solutions (FAQ) that is provided on page 6. Start-up ○ Start the pump only when the suction and discharge pipes are connected to the corresponding inlets and outlets. ○ Apply voltage to the motor and suitably adjust the jets to obtain the desired flow. Maintenance The pumps do not require any special maintenance or programming. If the pump will be idle for a longer period of time , it is recommended to disassemble , clean and store it in a dry , well ventilated place. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person immediately to a hazard.

SYMPTOM POSSIBLE CAUSE

CHECK NO POWER -Incoming power to the pump? -Is circuit breaker on? PUMP DOES NOT TURN ON -Is GFCL operating properly? -Is the air switch plugged in? -Is the air switch hose connected to the AIR SWITCH DISCONNECTED pump? -Is the air switch hose connected to the actuator button on the tub deck? PUMP NOT PUMPING PROPERLY BLOCKAGE OR LEAK -Jets should be pointed away from the suction inlet so air is not forced into pump suction. -Is the in tub suction inlet blocked or covered? -Is there any debris in the pump housing? -Is there a leak in the piping or the Pump? LOW VOLTAGE -Is the proper voltage applied to the pump? -Is there an extension cord being used?

Figure 1: Installation with connection pipe, drain and minimum water level

Figure 2: Measurements and technical specifications Model Kracht (P1) A B C D E F L H H1 H2 kW HP ZFPX5200 0.25 0.35 100 152.5 80 164 32.5 89 317 183 168 63 ZFPX5210 0.37 0.50 ZFPX5220 0.55 0.75 112 152.5 90 175 43.5 86 350 205 178 74

Figuur 3: Performance curves

Model Zwembad BVBA internal code JA35 ZFPX5200 JA50 ZFPX5210 JA75 ZFPX5220