DTS 600 Elite Installation Manual
Text of the manual
Base plate-mounting instructions
E-EEEE
DTS
SLIDING GATE MOTOR
INSTALLATION MANUAL
DTS 600 Elite with SL150 PCB
DTS SECURITY
P.O.BOX 3399
EDENVALE
1610
TELEPHONE 086 1000 387
Spartan +2711 392 5540 (H/O)
Pretoria +2712 361 5528
www.dtssecurity.co.za
1) Default settings & Error Codes and messages
2
2) Features
3
3) Gearbox mounting & Gate motor override
4
4) How set install the limit switch actuators
4
5) Power connection & Courtesy light connections
5
6) External connections
6
7) Programming (Calibrating the motor)
7
8) Motor direction setting
7
9) Auto close, Condo mode, PIRAC
Selectable motor direction change.
Auto close facility. (Infra-red beams must be fitted if auto close is activated).
Party mode. (Auto close override)
Condominium / Free exit loop facility.
P.I.R.A.C. (Passive Infra-Red Access Control) facility.
Slowdown (Ramp down) facility.
Tamper facility, Anti-hijack/Alarm facility.
On board Re
Gearbox mounting instructions
1. Fit gearbox over mounting bolts protruding from base plate.
2. Slide gate fully open and closed, insuring pinion gear has approximately 5mm clearance to gate at
all times.
3. Fasten gearbox down firmly to base plate using M10 washers and nuts.
How to override the gate motor for manual operation
1. Unlock and open the
High access power supply unit – 220V at motor. ( DTS600, 120VA has a 2 Amp fuse)
Connect 220V AC to LEN (Live/Earth/Neutral) connector on side of power supply unit.
Black lead from power supply unit gets connected to – ( neg.) HA PSU connection on PCB.
Red lead from power supply