Elan IRS1 Manual 

Text of the manual

Advanced IR Filtering Technology

The IRS1 features Advanced IR Filtering Technology that reduces IRI, CFL, EMI, and ESI noise sources in addition to blocking plasma TV emissions. This means that the IRS1 can be used in areas that receive substantial ambient noise such as near plasma TVs or compact floures- cent lights. Note: The IRS1 will take a few seconds to adjust to a given noise source. During this time, the blue Activity LED will glow brightly and then fade out. If the interference disappears momentarily, then returns, the fade down process will repeat. Certain noise sources, however, (such as plasma screens) may result in low-level flickering even after the fade down. This is normal. Such signals have been filtered, allowing most equipment to be controlled. Extreme Ambient Noise In situations where the IRS1’s advanced IR filtering does NOT success- fully filter ambient noise (in very close proximity to a plasma TV, for example), an ELAN IRS7EP or IRS8EP Extreme Plasma IR Sensor should be used. Please see the IRS7EP and/or IRS8EP Instructions for addi- tional information. IRS1 Miniature Surface-Mount IR Sensor w/Plug Limited Warranty ELAN HOME SYSTEMS, L.L.C (ELAN) warrants this product to be free from defects in materials and workmanship for five (5) years from date of purchase. If within the warranty period purchaser discovers such item was not as warranted above and promptly notifies ELAN in writing, ELAN shall repair or replace the items at the company’s option. This warranty shall not apply (a) to equipment not manufactured by ELAN, (b) to equipment which shall have been installed by other than an authorized ELAN installer, (c) to installed equipment which is not installed to ELAN’s spec- ifications, (d) to equipment which shall have been repaired or altered by others than ELAN, (e) to equipment which shall have been subjected to negligence, accident, or damage by circumstances beyond ELAN’s control, including, but not limited to, lightning, flood, ,electrical surge, tornado, earthquake, or any other catastrophic events beyond ELAN’s control, or to improper operation, maintenance or storage, or to other than normal use of service. With respect to equipment sold by, but not manufactured by ELAN, the warranty obligations of ELAN shall in all respects conform and be limited to the warranty actually extended to ELAN by its supplier. The foregoing war- ranties do not cover reimbursement for labor, transportation, removal, installation, or other expenses which may be incurred in connection with repair or replacement. Except as may be expressly provided and authorized in writing by ELAN, ELAN shall not be sub- ject to any other obligations or liabilities whatsoever with respect to equipment manufactured by ELAN or services rendered by ELAN. THE FORGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESSED AND IMPLIED WARRANTIES EXCEPT WARRANTIES OF TITLE, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ©2005 ELAN Home Systems P/N 224256 X2 Introduction The IRS1 is a miniature ‘plasma-friendly’ IR sensor designed to be mounted on flat surfaces: furniture recesses, under shelves, etc. This sensor uses advanced IR filtering technology which allows it to work even in areas that receive normally harmful interference (near plasma TV’s, compact flourescent lights, etc.). The IRS1 features a 3.5mm Quad plug for easy connection to IR distribution blocks, multi-room con- trollers, etc. The IRS2 Miniature Surface-Mount IR Sensor w/ Bare Leads is also available if the Quad Plug is not required. Features • 3.5mm Quad Plug Accommodates STATUS, IR, +12VDC, & GND • ‘Plasma-Friendly’ Technology Helps Block Plasma TV Interference • IR Lens Rejects Visible Light Interference • Internal Crosshatch Shield Inhibits EMI/ESI Interference • STATUS Indicator: Green LED for System On/Off Indication • ACTIVITY Indicator: Blue LED Indicates IR Signal Activity Specifications: • Requires 12VDC power supply, termination block and IR emitters for IR operation. • Mounting: Attach to any flat surface using included adhesive strip. Apply adhesive strip to the back, top, or bottom surfaces of the IRS1. • Power: +12VDC @ 6mA • Carrier Frequency Acceptance Range: 28kHz to 90kHz • Control Range: Up to 35 feet, depending on remote strength and ambient noise conditions. • Control Angle: +/- 50 degrees off-axis • Room-to-Room Wire Recommendations: Cat-5 • Maximum recommended cable length: 1200 feet using Cat-5 • Dimensions: 2 9/16" (65mm) L x 9/16"(14mm) W x 1/2" (13mm) D Status LED (Green) Activity LED (Blue) Striped Side 4-Conductor 3.5mm Plug +12VDC IR OUT GND STATUS IR Lens IR Pickup Diode 8' Lead IRS1 Fig. 1 2428 Palumbo Dr. Lexington, KY 40509 (859) 269-7760 www.elanhomesystems.com 1 4 guides.com

Stand-Alone System Connections:

Note: For ELAN system connections, please refer to the appropriate ELAN Multi-Room Controller’s installation manual. A: Basic System Fig. 2 shows a basic IR distribution system using the ELAN IRD4 Amplified IR Connection Block, IRS1 IR Sensor, and IRE1 IR Emitters to control various source equipment. 1. Mount the IRS1 IR Sensor in a recessed cabinet area or under a shelf, using the adhesive strip supplied. 2. Plug the IRS1 and IR emitters into the ELAN IRD4 as shown. 3. Set the dipswitches on the IRD4 to LP ON and NET ON or OFF. 4. Plug in the power supply. 5. IR signals sent to the IRS1 will pass through the IRD4 and control the equipment. B: Multi-Room System Fig. 3 shows an example of multiple IRS1 IR Sensors in a stand-alone multi-room system. These control the various components in the equip- ment area. 1. Pull Cat-5 from each room (home runs) to the IRD4 terminator near the controlled components. Note: MAX DISTANCE of ALL Wire Runs is 1200 ft using Cat-5 cable. When using long lengths, the dipswitch on the IRD4 must be set to the NET ON position and a 500 Ohm resistor must be used. 2. Connect IR sensors in each room to the Cat-5 runs as shown, using the terminal strips supplied. 3. Connect the Cat-5 wires to the correct location on the IRD4 connec- tion terminals (+12VDC, IR, STATUS, and GND). 4. Install and plug the IRE1 Emitters into the IRD4. 5. Set the dipswitches to LP ON and NET ON. 6. Plug the local IRS1 IR Sensor into the IR SENSOR jack. 7. Plug in the PWR2 12VDC Power Supply. 8. IR signals sent to the IRS1s will pass through the IRD4 and control the equipment. Note: Refer to the ELAN IRD4 Instructions for power supply considerations and other important information. STATUS Brightness Fig. 3 also shows how an external resistor can be added to reduce the brightness of the Status LEDs on ELAN IR sensors. In this example, a PWR2 12VDC Power Supply is used as the voltage source to indicate ON/OFF status of an A/V Receiver. Choose a resistor value that achieves the brightness you desire (about 2.2k to 12k, 1/8W). Connect it in series with the STATUS lead on each IR sensor, as shown. To 120V AC (unswitched) PWR2 Power Supply Digital Music Server Satellite DVD IRS1 Miniature IR Sensor IRE2 Talk-Back Emitter Remote Control IRE2 Talk-Back Emitter IRE1 IR Emitter IRD4 Amplified IR Connection Block Fig. 2 To 120V AC (unswitched) PWR2 Power Supply A/V Receiver Satellite DVD IRD4 Amplified IR Connection Block IRS6 In-Wall IR Sensor IRS2 Surface-Mount IR Sensor IRS1 IR Sensor IRE1 Emitter IRE2 Talk-Back Emitter ROOM 1 ROOM 2 ROOM 3 PWR2 STATUS Supply To Switched AC Outlet IRE2D Dual Talk-Back Emitter To Additional Controlled Unit Rear View Add a Resistor at each IR sensor to reduce STATUS brightness, if desired. See text. Striped Side STATUS +12V GND IR OUT STATUS +12V GND IR OUT Connection Terminals Wh/Blue IR Blue STATUS Wh/Green +12 VDC Brown GROUND IRS2 Surface-Mount IR Sensor Connection Block Supplied w/ IRS2 Fig. 3 2 3

Other Kitchen Appliances Manuals