ASP - 10 STAIRCASE TIMER

INSTRUCTION MANUAL Zakład Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. Łodzińska ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: [email protected] APPERANCE FEATURES DESCRIPTION یStaircase lighting control, یContinuous ON-time (t) adjustment of 10 seconds to 16 minutes, یSoft switch ON (0.8 s), یSlow switch OFF (15 s), یCounter-interlock and retriggering, یDevice triggering by means of the L wire, یApplicable together with single pole push buttons, illuminated, یTwo-conductor control system, یEasy applicable together with any existing electrical system, یSupplied in series with load. The ASP-10 staircase timer is de- signed for corridor and staircase lighting control. After the circuit triggering the timer keeps the light ON for the preset time and then switches it OFF. It has an adjustable ON-time (t) setting of 10 seconds to 16 mi- nutes. On-time may be adjusted by means of a potentiometer. The ASP-10 staircase timer may by applied as a time relay for de- layed switch-OFF. It is possible to mount the device under a push button, in a deep junction box of 60 mm diameter. TECHNICAL DATA ASP - 10 Power leads: L(black), brown - in series with the load Rated voltage: 230 V~ Rated voltage tolerance: -15 ÷ +10 % Rated frequency: 50 Hz Rated current: 10 mA Trigger conductor: IN (red) Load supply: brown ON-time (t) adjustment range: 10 s ÷ 16 min ON-time setting accuracy: ±3 % ON-time setting repeatability: ±5 % ON-time setting: continuous (potentiometer) Load supply indicator: red LED Permissible load: 30 ÷ 300 W Fuse technical specification: 5 x 20 mm, ultra-fast, 2 A / 250 V Control: triac Connection wires quantity: 3 Connection wire section: 1 mm2 Connection wire length: 10 cm Operating temperature: -20 ÷ +45 oC Operating position: optional Casing fastening: for 60 mm junction box Casing IP: IP40 Protection class: II Overvoltage category: II Pollution level: 2 Dimensions: 50 x 50 x 15 mm Weight: 25 g Standard conformity: PN-EN 60669-1; PN-EN 60669-2-1 PN-EN 61000-4-2,3,4,5,6,11 Load ON indicator ON-time setting Load supply lead Power lead (L) Fuse socket Trigger lead (IN) br o wn re d bl ac k The device should be connected to a single- phase system accordin- gly to current standards. The device connection swill be described in this manual. Only qualified electricians are allowed to connect, assembly and adjust the timer. It is ne- cessary to read this manual before the timer mounting. Do not disassembly the timer casing or you will lose any war- ranty rights and expose yourself to the electric shock hazard. Before mounting operation make sure of disconnecting the connection wires from the electric network. Use a cross-head screwdriver of 3.5 mm diameter to mount the devi- ce. The timer should be carried, stored and used in an appropriate way. Do not mount the timer in case of any device parts lack, damage or deformation. In case of malfunction please notify the manufacturer. CAUTION

The timer is ready to work just right

after its appropriate connecting. The light will be ON for the preset ON-time (t) after the timer is triggered by means of a single pole push button. When the preset time is over, the light will be OFF automatical- ly until the timer is triggered once again. The staircase timer may be connected either to three-conductor or four-conduc- tor wiring. Check carefully if the trigger and load circuits have been connected correctly. The timer is fitted with the soft start (0.8 s) and slow switch-OFF (15 s) functions. The switch-OFF-time has been elongated in order to inform the user that the ON-time is over and let him press the triggering push button again. This way the ON-time counting will start once more and the light will brighten up again. The timer is fitted with a counter-interlock cir- cuit. If the triggering push button is blo- cked, the circuit switches OFF the light after the ON-time (t) is over and interlo- cks the retriggering function which enab- les the light ON-time elongation in case of pressing the triggering button again while the light is still ON. 1. Disconnect the electric network by me- ans of an appropriate cut-off, current- limiting circuit-breaker or separator. 2. Check if there is no any voltage be- tween power leads by means of an appropriate gauge. 3. Place the ASP-10 device in a box and connect wires accordingly to electrical diagram. 4. Connect power supply circuit. 5. Adjust the light ON-time. CASING DIMENSIONS UNIT DIAGRAM TIME DIAGRAMS PRODUCT FAMILY ASP-10 is a member of the ASx staircase timer family. μC LOAD br ow n re d bl ac k br ow n re d bl ac k Device version: 01 – three - or four-conduc- tor wiring 02 – built-in counter-intelock- ing circuit 10 – dimmer function Casing type: M – single-module N – surface-mounted H – hermetic P – for junction box mounting Device symbol 24 V AC/DC version for ASM-02 availalbe ASx - xx (/24V)