Text of the manual

This document was made for the M2M PRO4 MODEM® device and it contains all relevant

installation steps of the device. Document category: Installation Guide Document subject: M2M PRO4 MODEM® Author: WM Systems LLC Document version No.: REV 0.92 Number of pages: 34 Hardware version: BE008x Linux Kernel: 4.14.23 OpenWRT software version: 202002071 Document status: FINAL Last modified: 17 February, 2020 Approval date: 17 February, 2020

Table of contents

1. WIRING AND PREPARATION ........................................................................ 4 1.1 Description of interfaces ..................................................................................................... 4 1.2 Safety declaration .............................................................................................................. 4 1.3 Mounting, fixation .............................................................................................................. 8 1.4 Cabling, wiring ................................................................................................................... 9 1.5 Important notes ................................................................................................................. 12 1.6 Understanding the LED signals ............................................................................................ 13 2. INSTALLING THE MODEM ............................................................................ 14 2.1 The very first startup .......................................................................................................... 14 2.2 Normal startup ................................................................................................................... 14 2.3 Local access via USB .......................................................................................................... 17 2.4 Web user interface and Login ............................................................................................. 18 2.5 SSH access ........................................................................................................................ 20 2.6 Wireless access .................................................................................................................. 20 2.7 LED indication .................................................................................................................... 22 2.8 Power On / Supercap Charging mode .................................................................................. 24 2.9 Service features ................................................................................................................. 25 2.10 Alternative installation of the OpenWrt® system ................................................................. 26 3. MODEM CONFIGURATION (MAIN IMPORTANT SETTINGS) ............................ 29 4. SUPPORT..................................................................................................... 31 5. DEVICE DATA, CERTIFICATION ................................................................... 32 5.1 Datasheet of the device ...................................................................................................... 32 5.2 Wireless module certification ............................................................................................. 33 6. LEGAL NOTICE ............................................................................................ 34

1. Wiring and Preparation

1.1 Description of interfaces  1 – ~100 - 240V AC power input plug (4-pins terminal block), the pinout from left-to-right is the following: L, N, -, PE  2 – micro USB connector (PC connection - for configuration, alternative DC power input)  3 – SIM (2FF-type mini SIM card slot, push-insert SIM holder)  4 – RS485 port (isolated RS485, half-duplex data interface, RJ12 connector), for up to 31 meter connection  5 – Reset button (hole) – has multiple features, see Reset features chapter later  6 – ANTENA – Antenna connector for 4G LTE wireless network usage, SMA-M, 50 Ohm 1.2 Safety declaration The device must be used and operated according to the related user manual. The installation can be carrying out only by a responsible, instructed and skilled person by the service team, who has enough experience and knowledge about carrying out the wiring and installing a modem device. Its prohibited to touch or modify the wiring or the installation by the user. It is prohibited to open the device enclosure during its operation or under power connection. 2 3 4 6 5 L N PE 1

It is also prohibited to remove or modify the device PCB. The modem and it’s parts must not be

changed by other items or devices. Any modification and repairation is not allowed without the permission of the manufacturer. It all causes the loss of product warranty. Caution! Only a certified expert or the manufacturer is allowed to open the enclosure! By general the device is using AC mains. 100-240V AC, 50Hz, electric shock hazard inside the enclosure! DO NOT open the enclosure and DO NOT touch the PCB. (Consumption: Min. 2W / Average: 3-4W / Max: 10W The IP51 immunity protection will be effective only in case of under normal usage and operation conditions with unharmed hardware conditions by using the device in the provided enclosure/chassis. Deliberate damage or occing casualty of the device means the loss of product warranty. To ensure general safety, please follow the following guideline! ■ Keep the chassis area clear and dust-free during and after installation. ■ Keep tools and chassis components away from walk areas. ■ Do not wear loose clothing that could get caught in the chassis. Fasten your tie or scarf and roll up your sleeves. ■ Wear safety glasses when working under conditions that might be hazardous to your eyes. ■ Do not perform any action that creates a hazard to people or makes the equipment unsafe. Safety with Electricity Follow this guideline when working on equipment powered by electricity. ■ Read all the warnings in Safety Warnings. ■ Locate the emergency power-off switch for your installation location. If an electrical accident occurs, you can quickly turn off the power.

■ Disconnect all power before:

– Installing or removing a chassis – Working near power supplies ■ Look carefully for possible hazards in your work area, such as moist floors, ungrounded power extension cables, frayed power cords, and missing safety grounds. ■ Do not work alone if hazardous conditions exist. ■ Never assume that power is disconnected from a circuit. Always check. ■ Never open the enclosure of the modem’s internal power supply. ■ If an electrical accident occurs, proceed as follows: – Use caution; do not become a victim yourself. – Turn off power to the device. – If possible, send another person to get medical aid. Otherwise, assess the victim’s condition and then call for help. – Determine if the person needs rescue breathing or external cardiac compressions; then take appropriate action. Preventing Electrostatic Discharge Damage Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. It may occur if electronic printed circuit cards are improperly handled and may cause complete or intermittent failures. Always follow ESD prevention procedures when removing and replacing modules: ■ Ensure that the modem chassis is electrically connected to earth ground. ■ Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to channel unwanted ESD voltages safely to ground. To guard against ESD damage and shocks, the wrist strap and cord must operate effectively. ■ If no wrist strap is available, ground yourself by touching a metal part of the chassis. Caution: For the safety of your equipment, periodically check the resistance value of the antistatic strap. It should be between 1 and 10 megohms (Mohm).

IMPORTANT SAFETY INSTRUCTIONS

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. SAVE THESE INSTRUCTIONS Warning: Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. Statement 43 Warning: In order to comply with FCC radio frequency (RF) exposure limits, antennas should be located at a minimum of 7.9 inches (20 cm) or more from the body of all persons. Statement 332 Warning: Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001 Warning: Before performing any of the following procedures, ensure that power is removed from the DC circuit. Statement 1003 Warning: Read the installation instructions before you connect the system to its power source. Statement 1004 Warning: This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 20A. Statement 1005 Warning: This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017 Warning: The plug-socket combination must be accessible at all times, because it serves as the main disconnecting device. Statement 1019 Warning: This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024 Warning: This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028

Warning: Only trained and qualified personnel should be allowed to install, replace, or service

this equipment. Statement 1030 Warning: Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 Warning: To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of: Statement 1047 Warning: Installation of the equipment must comply with local and national electrical codes. Warning: To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 inches (7.6 cm). Statement 1076 Warning: Hot surface. Statement 1079 Caution: This metering modem can only be accessed by service personnel or by users who have been instructed about the reasons for the restrictions applied to the location. Access is through the use of a tool or lock and key, or other means of security, and is controlled by the authority responsible for the location. Caution: Be aware of the size and weight of the metering modem when mounting. Ensure that the mounting location has a stable flat surface and can safely support the weight of the device. 1.3 Mounting, fixation The device enclosure (unit) contains a DIN-Rail fixation due its case, which is to be intended to mount to DIN-35 rail or using a 3-point fixation by screws, or using the hook (in hanging position). You can also mount the enclosure to wall, place into server rack or similar fixation opportunity. The unit must be mounted inside a cabinet by the listed fixation points, in vertical orientation. Please note that close metal parts, the cabinet metal material and the industrial conditions as the usage of high rate power or other external gained radio frequency signals can cause radio signal disturbance and could cause weak wireless signal at reception or data transmitting or could cause less effective signal reception, weak wireless fidelity. In any of these, we recommend you to test the wireless signal reception and quality and if it is necessary use external, magnetic mount antenna which is leaded outside of the cabinet and placed onto the cabinet’s surface – to ensure enough reception.

Figure of bottom side of the unit enclosure

 A – Device housing case back plate  B – Hook for fixation to wall/mount  C – DIN-rail sleede for fixation  D – DIN-rail position holder (release/fixate)  E – Additional hooks for fixation to wall/mount 1.4 Cabling, wiring 1. Remove the plastic, transparent port protector part (No. 8) by releasing the two screws (No. 7) from the top of the enclosure and slide up the plastic part carefully from the protector’s rails (No. 9), then remove it from upside direction. Now you can free to connect wires and cables to the ports and interfaces. 2. Mount a 4G LTE antenna to the ANTENA titled (no. 6) SMA antenna connector. Twist the antenna to the connector until it is fastened. B A C D E E

You can use 4G LTE wireless

antenna with 3-6dB, 9dB or more gained versions. RG174 cable SMA antenna with magnetic mount can be used for external usage. The antenna must be placed and oriented that it should has a some clearance in any direction. 3. Insert and push an activated mini SIM card to the SIM titled card holder (No. 3), top SIM holder. Insert by following the hints of SIM card figure for the proper orientation. (The SIM chip-side will be face down and the cutted edge towards to inside and push until it sleeves). 4. You can use the micro USB (No. 2) connector with a microUSB-to-USB cable connection as USB LAN - instead for configuring or access the device. 5. You can use the micro USB port (No. 2) to power the modem by DC power (5V) instead of using the 100-240V AC power (as an alternative way for powering). 2 3 4 6 5 1 7 7 8 6 9 9

6. By default, the modem has an installed OpenWRT® operating system which is ready to use

and configure to your SIM card APN and for you usage requirements. 7. Plug the 100-240V AC power supply connector to the 100..240V AC interface (No. 1), then plug the power cable to the external electricity plug – according the orientation of the power connector and the pinout (from left-to-right: L, N, -, PE), where L=phase, N=neutric, PE=ground. Add a stable AC power to the device. Current / power consumption (AC power source) – mains input  Power supply / Voltage range: ~100-240V AC, 50 Hz  Current: 0.1A at ~100-240V AC Consumption: 3W - 10W The following cables are not part of the accessories of the delivered package Use the following hints and the recommendation to choose useful cable and type to prepare the necessary connection(s) according to your requirements. AC cable (optional): The power cord 70 cm type, OMYA 4 x 1 mm^2, voltage Insulation min. 500 V, maintaining colors and ends with the power supply enabling connection to a 240 V AC Function: ~100-240V AC power supply to the modem Pins must be wired for usage: L, N, -, PE (see schematic for pinout) RS485 cable: Type: 2 + 3x LgY 0.75 mm2 Connector type: RJ12 Function: / R485 connector to external IEC1107 or DLMS/COSEM protocol compatible utility meters In case of presence of ~5V DC (by using the USB interface for alternative power source) (No. 2 interface) to connect DC supply power for the device – instead of using the AC power input (No. 1. interface), the following declared current values are the valid. Current and power consumption (AC power source / mains)  Power supply / Voltage range: 5 VDC  Current: 800mA at 5V DC  Consumption: 3W - 10W W

microUSB-USB configuration cable:

Type: microUSB–to–USB cable Connector type: USB 2.0 micro Type-B connector Function: for configuration – connecting the device to a computer or provide alternative power source: DC power (5V DC) Schematic figure of wiring, interfaces, pinout 1.5 Important notes  The modem has 4G wireless transmission capabilities and 2G/3G fallback in case of the unavailability of the 4G network. In this case, the device will operating on the 3G or 2G network. When the 4G network will be available again, the device will switch back to the 4G network. This feature is configurable for the WAN interface of the device.  You have to use the LTE antenna for the sake of a stable wireless network operation. You can check the current signal reception and wireless availability in the OpenWRT® / LuCi® system’s Overview menu.  The available APN settings will be assured by the SIM card provider mobile operator or your mobile internet service provider. Ask them about APN, password, SIM PIN and further necessary information for the configuration.  When configuring the SIM #1 APN or PIN settings, after the saving, the modem will not restart its module automatically with the new settings. You need to restart the modem by the Restart WAN button in the OpenWrt® menu at Network / Interface settings.  The utility meter readout through the RS485 port is possible only by using and connecting IEC1107, DLMS compatible (IEC 62056-21, IEC 62056-31 supported) devices.  You have to configure the RS485 meter connection settings at the Network/IEC scheduler menu item.

1.6 Understanding the LED signals

The device has 16 LEDs to assign the modem’s current status, the communication, connection. These LEDs are located in four groups: - Operation status LEDs (Group A) o MOC – Power source connected / mains on o WL – The modem has started o LADOWANIE SUPERCONDENSATORA (in case of exhausted super-capacitor part which shows the process of the recharge – when the charge has been finished, the LED will be blank again) - Connectivity LEDs (Group B) o 4G-WAN – wireless network connection and access o USB connection (on the micro USB port) o BLAD – for sign possible failures, kernel-level events, stand-by mode - Cellular network signal strength indication LEDs (Group C) o signal 1 to signal 4: wireless signal reception (higher is better) - Data connections and activity LEDs (Group D) o RS485 TX - connection and activity (data transmitted) - on the RJ12 connector o RS485 RX - connection and activity (data received) - on the RJ12 connector o Pamiec – memory activity (data read, write in the non-volatile memory) The power indication group (group A) and signal level leds (group C) are is fixed, but the other 9 LEDs (group B and group D) are reconfigurable. D C A B

Installing the modem

2.1 The very first startup The modem has a super-capacitor part inside, which protect the device against possible shorter power outages. It can also provide RTC backup for the device, up to 2 days. Therefore, this supercap component can be charged and it can be exhausted after an outage or if you store the modem for months without connecting power source or using. Start the device by the adding the AC power (No. 1) or DC power (via USB port at No. 2) source and pushing the Reset button (No. 5) for 2 seconds by a sharp object (e.g. by a pen) – while the ON led will be also active (the PWR and ON leds are lighting by green colour) – then you can release the Reset button. Then the modem will start immediately and charging the supercapacitor (LADOWANIE SUPERKONDENSATORA led will be also active – by yellow colour). Next time you don’t need to push the Reset. You can stop it by removing the power source and start it by adding the power source. 2.2 Normal startup The modem has a pre-installed system (which contains the device firmware and the pre-configured OpenWrt® system). After adding the power source to the modem, you will just need to configure some necessary and unique settings for your SIM card, network access, and some other required connection parameters.

Start the modem by the following sequence.

1. Ensure that you have inserted an activated SIM card into SIM holder (No. 3) in the right position. The usage of SIM holder is obligatory for using the wireless communication. 2. Ensure that antenna is mounted to the SMA interfaces (No. 6). 3. After plugging the AC power source (No. 1), the modem begins to perform booting – the LED signals are always showing the current activity during the operation. The system start needs about 40-50 seconds while it will be ready for usage, network communication. 4. During the boot, the modem begins to operate, whereas its LED signals are showing the current activity during the operation. During the boot sequence: a.) The MOC (power) and WL (ON) leds are also active (lighing by green). b.) Then the first two connection LEDs are (untitled ont he following figure) ligthing for ~10 seconds during the firmware start. c.) Then the 4G-WAN, USB leds will be also flashing for 30 seconds during the boot process.

d.) At the end of the boot process, only the 4G-WAN, USB leds will be flashing for 5-10 seconds.

e.) When the connectivity LEDs are not blinking anymore the load of the system has been finished. f.) The SILA SIGNALU (SIGNAL LEVEL) low LED(s) are blinking which means the modem tries to connect to the wireless network. If it was configured properly (APN, password and SIM PIN is matching) and the network registration was also succesful, the 4G-WAN led will be lighting with the SIGNAL LEVEL leds will be also lighting (by signing the current wireless signal strength). This means that the modem is already connected to the cellular network and it has enough wireless signal reception for the usage and wireless data transmitting. g.) If you already connected the USB cable, the USB led will be active.

h.) The RS485 RX led (in case of meter data receive) or the RS485 TX led (in case of sending

data to the meter) will be active – which signs the data traffic, modemmeter activity. When the USB led is active during the load of the system, this signs that the device is already accessible on its USB interface – it is possible for you login at the LuCi® web user interface (or connect to the modem via SSH). 2.3 Local access via USB connection 1. Download, unpack and install the USBLAN driver for using the USB connection: https://www.m2mserver.com/m2m-downloads/USB_Ethernet_RNDIS_DRIVER.zip 2. After you’ve connected the USB to micro-USB cable, you can add the driver in the Windows® / Start / Control Panel / System / Device Manager. Find the Network Cards, extend it and you will found the „USB Ethernet / RNDIS Gadget”. Double click on the entry and choose the Driver tab, and the Refresh button, then browse the uncompressed file’s directory then Install the driver.) 3. Build a connection between the PC and the modem with a microUSB-to-USB cable. 4. Configure the USB-Ethernet interface IP address on your PC for the „USB Ethernet/RNDIS Gadget” and setup the next fixed ipv4 address: 192.168.10.10, subnet mask is: 255.255.255.0 – connect these settings. (You can ping the device through the USB connection on its IP address.) 5. The USBLAN interface IP address is 192.168.10.1 For connecting to the modem on web interface use the https://192.168.10.1 URL.

2.4 Web user interface and Login

1. The modem’s local web user interface (LuCi®) is reachable through the Ethernet or USB interface – on the default addresses. 2. Enter the default web user interface (LuCi®) of the modem. The USB web interface default URL is: https://192.168.10.1 3. Use the Mozilla® browser! In your browser window you will get a security risk message. Ignore the security message and choose the Advanced option here. 4. Then click on the Accept the Risk and Continue button to access the modem webpage. Attention! For accessing the web user interface we recommend to use the Mozilla Firefox® web browser. Other browsers cannot be used.

5. The OpenWRT® system’s LuCi® web interface has loaded into your browser. Now fill the

Username and Password fields and click on the Login button for the entry.  Username: root  Password: wmrpwdM2M

2.5 SSH access

The modem can be accessed through SSH connection, when it is available on its IP address – by a terminal utility (e.g. the putty tool). Putty is a free tool which can be downloaded from the following URL: https://www.chiark.greenend.org.uk/~sgtatham/putty/latest.html The modem can be accessed on SSH at the 192.168.10.1:22 (port nr. 22 - on USB interface). Allow to acccess the device, ignore the security breach message in your computer in the pop-up window. Choose Accept (Yes) at the Putty or other SSH terminal’s Security Alert of the RSA2 key of the modem to allow and trust the connection – by security reasons. SSH login data:  Login as: root  Password: wmrpwdM2M Now you are logged into the OpenWrt®’s Linux command line. The operating system uses the embedded Micro uCLinux, kernel 4.4 version, therefore you can use standard and compatible Linux commands – if you want. 2.6 Wireless access Before using the wireless access you need to setup the SIM card’s current APN properties at the OpenWrt® web interface. You have to configure these settings (SIM and APN) for connecting to the wireless network properly.

1. Choose the Network / Interfaces menu, WAN interface, Edit button.

2. Add the SIM #1 APN (APN setting of your SIM card)

3. If you have PIN code on the SIM card that you are using, add the right PIN here. (Ask your

Mobile Operator about the SIM info.) 4. If that is necessary to use username (SIM #1 PAP/CHAP username) or password (SIM #1 PAP/CHAP password) for the wireless network access, consult with your mobile provider and change the settings here, please. 5. Check that Protocol must be PPP-4G - if its not configured, choose this and push to the Switch protocol button and configure the APN, SIM settings. 6. In case of roaming change the Mobile country code (MCC) settings to the related country code please. 7. If you are attempting to use a dedicated cellular network, configure the MNC field (Mobile network code) please, according the needs. You will found the current valid and useable MCC / MNC settings on this official website: https://www.mcc-mnc.com/ 8. Click on the Save & Apply button to store the settings and configuring APN for the modem. 9. Soon the wireless module will be configured regarding the settings. Now the modem will try to connect and register the SIM card to the network. The availability of the mobile network is assigned by the 4G-WAN LED (lighing by green). 10. When it has sucessfully registered to the given APN, the 4G-WAN LED will lighting by green and the SILA SIGNALU (SIGNAL LEVEL) will be also signed according to the signal reception (it is lighing by green).

If the module with the SIM card was connected, the module is immediately generating data

traffic on the network where the Rx/Tx values will be continously growing/changing for the Interface status at the Interfaces / Interface Overview part for the WAN interface. This means that the wireless Internet connection (4g-wan) is already active. 2.7 LED indication The default LED signal indication is listed here. The B-D group of LEDs can be changed if you need in the OpenWrt® web interface. Description Colour Reconfigurable No light Flashing Continously light Group A MOC No / FIXED No power N/A AC Power supply OK WL No / FIXED The modem’s power supply removed N/A Power supplied / The device has been started LADOWANIE SUPERKONDENSATORA No / FIXED Supercap/Battery is fully charged (no need to charge) N/A Supercap/Battery is exhausted and it is currently charging Group B - Yes, Programmable Inactive No No - Yes, Programmable Inactive No No 4G-WAN Yes Inactive transmission channel on cellular network, module not/not properly configured - Active data transmission on the 4G LTE cellular network USB Yes No connection to the USB port Data flow, alternative DC Power Connection to the USB port, DC powered BLAD Yes No Error Error Group C SILA SIGNALU (,,,) Yes Cellular network signal strength 4 signal – Signal is above 97dBm (very good reception) 3 signal – Signal is above 85dBm (average reception) 2 signal – Signal is above 65dBm (poor reception) 1 signal – Signal is below 50dBm (weak reception) 0 signal – No signal (no reception)

RS485 data transmission

(transmit: TX) Outgoing data flow, data transmitting via the RS485 port No RS485 RX Yes, Programmable RS485 data reception (receive: RX) Incoming data flow, receiving data via the RS485 port No - Yes, Programmable Inactive No No Pamiec Yes, Programmable No activity at flash memory Data read from /write to the non- volatile memory No 2.8 Power On / Super-capacitor charging mode Normal operation (AC or DC power supply connected) The normal usage is assigned, when you are adding power supply to the 100..240V AC or 12..24V DC (USB) connector. The modem’s MOC (Power) LED will ligting by green and then the WL (ON) LED will also lighting by green colour when the system has started. There should be LED activity on the USB interface – if you are connected by USB cable with your PC. When the wireless network registration was successful and the modem is operating on the 4G network, the 4G-WAN LED should is also active (lighing by green). No Power supply / Power supply removed / Power line outage If the DC power supply was removed or in case of a detected electricity / power outage, after min. 5 seconds the modem will be disconnecting all interfaces, file systems and will be halted.

This plus operation time is possible due to the internal super-capacitor component – which

provides safe backup power for short time outages. During the shutdown process only the WL (ON) LED will be lighting by green, but the MOC (Power) LED will be blank. When the shutdown process has been finished, all LEDs will be inactive. Replug power input, connect power supply / Stabilizing the power In case of providing the power source (replugging the power supply) or stabilizing the outage of the power source, the modem will getting enough power again and automatically starting. During these the MOC (Power) and WL (ON) LEDs will be active (ligthing by green). Because the supercapacitor was used previously, it needs to be charged - therefore the LADOWANIE SUPERKONDENSATORA led will be also active during the charging process (ligthing by yellow).

2.9 Service features

The modem has various service features which can be controlled manually - just for the case – which can be initiated by pushing the Reset button (no. 5). By any reason, if you need to stop or start the device immediately or you cannot login into the system, you can start or stop it manually here. It is useful when the modem was misconfigured or the installation process failed, IP address or the password was loosen. Here we’ve listed all Service features of the Reset button which can be selected by manually. Push RESET Legend LED / signal 2 sec START the modem (when it was stopped before, AND the device has power source) the WL (ON) led will lighting (green) 6 sec Power off / STOP the device (if it was operating) all LEDs will inactive, only the MOC (Power) led is active (green) 4 sec SERVICE MODE MENU of the modem (if the device is operating) – the menu is active for 1 minute the BLAD led will lighting by red, while the service mode is active The modem Service menu has 4 modes (the menu is active for 1 minute only, while you can be select a mode from the menu by pushing the Reset button until 1sec). The following modes can be selected from the menu, here: - MENU ITEM 0 (no short push) – reboot - MENU ITEM 1 (1x short push) – restoring the default configuration - MENU ITEM 2 (2x short push) – restoring the factory configuration - MENU ITEM 3 (3x short push) – exit from menu

Then after the selection, the choosed menu item number is flashed by the BLAD led (e.g. flashing

twice in case of selecting the MENU ITEM 2). Then you need to confirm the choosen menu item for executing by a longer 6sec Reset push. Some examples: a.) RESTART the modem: - The modem must be operating - Push the RESET button for 4sec (entering the service mode) – BLAD led is lighting (red) - Push the RESET button again for 6sec (selected: mode 0 (restart) and confirm your selection) - The modem will restarts itself immediately b.) Restoring the DEFAULT configuration to the modem: - The modem must be operating - Push the RESET button for 4sec (entering the service mode) – BLAD led is lighting (red) - Push the RESET button again once for 1sec (selected: mode 1 (restoring default config)) - BLAD led (red) is flashing once per second - Push the RESET button again for 6sec (confirm your selection) - The modem will delete the current configuration and restoring the default configuration and restarting itself with loaded default configuration – if the default config doesn’t exists, it is restoring the factory config. c.) Restoring the FACTORY configuration to the modem: - The modem must be operating - Push the RESET button for 4sec (entering the service mode) – BLAD led is lighting (red) - Push the RESET button again twice for 1sec with a short pause (selected mode: 2 (restoring factory config)) - BLAD led (red) is flashing twice per second - Push the RESET button again for 6sec (confirm your selection) - The modem will delete the current configuration and restoring the factory configuration and restarting itself with the original configuration.

2.10 Alternative installation of the OpenWrt® system

By default, we deliver the Pro4 Modem device with the pre- installed OpenWrt® system. But, if it is necessary, the device can be reinstalled from a connected USB stick, through an OTG cable (micro-USB to USB-A). The device firmware must be written to a USB drive/stick by the Win32 Disk Imager tool. The software can be downloaded from its website: https://sourceforge.net/projects/win32diskimager/ Download the device firmware - uSD installer version - from our website and unpack the file (uncompress the file which now has.img extension): https://www.m2mserver.com/m2m-downloads/Pro4_PGE-Modem-NKM_uSD_Installer.202002071.zip Start the Win32 Disk Imager tool and browse the unzipped IMG (image) file on your computer, select the USB device’s drive name (be careful at selection because all content will be stored from the selected drive!) and push the Write button. The image file will be stored on the USB stick. Connect the USB stick to a the cable to the modem device and power on the modem. The modem will install the device from the USB stick – which will be signed by the device’s led signals. After the installation it will reboot. Remove the OTG cable and the USB stick and connect the normal micro-USB to USB cable to your PC and the modem, and configure the modem.

3. Modem configuration (main important settings)

Important! The modem has been uploaded by a pre-configured system. Check the configuration, and if the settings are not match with your expectations, please change the configuration settings and save them. The modem will be automatically apply your settings. When you have logged in, at the startup screen (Status/Overview) the web interface can be seen with all relevant information and the current status of the modem. The M2M Software version should be 202002071 or newer. If it has an older version, then refresh the firmware, please. (Check the User Manual for further steps).

You have to configure the 4G connection and APN/password (for SIM).

SIM/APN settings: In the OpenWrt menu, choose the Network / Interfaces menu, WAN interface, Edit button. 1. Ask your Mobile Operator about the SIM card information. 2. Add the SIM #1 APN settings according the SIM card info – ask with your mobile provider. 3. Check and add the PIN settings and username, password settings if you have to use them on the current cellular network (if your SIM card using these). 4. Store the wireless network settings by the Save & Apply button. 5. Soon the wireless module will be configured regarding the settings. If the module with the SIM card is operating network traffic Rx/Tx values will be continously growing/changing at Interface status: Interfaces / Interface Overview part, wher WAN interface means the public wireless Internet connection (as lte-wan) – which assigns the physical 4G module. Important! In case of network outage, the wireless and wired data and interface connections, sessions will be reconnected as the power source estabilished and the network is reachable. IP settings: 1. By default the device IP address is static, the default IP address is: 192.168.10.1. 2. If you want to switch the USB-LAN interface (usb0) at network settings - at the EDIT part - to dynamic (at Protocol field), then the modem will waiting for an IP address on the network. 3. If you want to use the local DHCP server – to allow to add IP addresses by the modem for the connecting external networking devices – then the right setting is the Static Address, and the IP address should be also changed, and you have to uncheck the DHCP disabled optionfor the USB-LAN interface to allow the DHCP server. 4. In case of using DHCP server, you can define the IP range (Start, Limit) and you can define IPv4 netmask for your network. 5. When changing the Protocol field, you will need to push the button. Save your settings by the Save & Apply button. Then the bridged USB-LAN interface IP address will be changed according your request due to the new settings. 6. Further detailed settings can be found in the User Manual document.

4.1 Contact support

If you have any questions concerning the usage of the device, contact us at the following contact: E-mail: [email protected] Phone: +36 20 3331111 Online product support can be required here at our website: https://www.m2mserver.com/en/support/ For the proper identification of your device, use modem sticker and its information, which contains important information for the call center. Due to the support questions, the product identifier is important for resolve your problem. Please, when you are attempting to tell us an incident, please send us the IMEI and SN (serial number) information from the product warranty sticker (located on the front face of the product housing). The documentation and software release for this product can be accessed via the following link: https://www.m2mserver.com/en/products/m2m-pro4-modem/ 4.2 GNU/Linux license and open source code The modem operating system and OpenWrt®/Luci open source code is available on our website at the product site. The modem’s software is under GNU/Linux licensing. Product URL: https://www.m2mserver.com/en/products/m2m-pro4-modem/ There at the Downloads tab at the middle on the modem website, at the Source Code part you will found the source code of the modem software and GNU/Linux license notice.

6. Device data and certification

5.1 Datasheet of the device Power Voltage / Current • Dual Power / Mains: AC power supply from 100..240V AC, 50 Hz, 600mA current / alternative 5V DC mains (via USB powered conn.) Consumption • Average: 3-4W • Max.: 10W System Performance • T2 Dual-Core Cortex-A7 ARM 700MHz processor / 128MB memory / non-volatile memory for data storage Wireless LTE module Module Type / Release • Telit LE910C1-EU • LTE FDD Cat.1 3GPP release 9 compliant Bands / Frequency (MHz) • GSM/GPRS: B3(1800), B8(900) • UMTS: B1(2100), B3(1800), B8(900) • LTE: B1(2100), B3(1800), B7(2600), B8(900), B20(800), B28A(700) Speed (DL/UL) • LTE Cat.1: 10/5 Mbps • HSPA+ Cat.20/Cat.6: 42/5.7 Mbps Interface / Antenna • The wireless module is assembled on the motherboard • SMA 50 Ohm antenna connector Interfaces SIM card • SIM card slot: 2FF type mini SIM card - internal protection against spontaneous falling out RS485 port • Isolated RS-485 data interface (RJ12, half duplex, 300 - 19 200bps) for 1 to 31 protocol compatible utility meters (IEC1107 or DLMS/COSEM) microUSB port • microUSB connection (for alternative DC power source, local configuration) User interface OS / Services • OpenWrt® embedded device operating system, WebGUI (LuCi®) interface • Meter protocols: IEC1107, DLMS/COSEM (IEC 62056-21, IEC 62056-31) • Network protocols: TCP, ser2net, FTP, NTP time sync, SSHv2 access • Server connection: FTP service (automatic data upload through WAN connection) Security • Diagnostic and monitoring of operation parameters • Modem event logging • Safe and local storage of data in the non-volatile memory • Super-capacitor protection against power outage, RTC backup up to max. 2 days Remote Access / Remote Configuration • Configuration: web user interface (configuration, firmware replacement) via local or remote TCP connection • Remote access and CLI: SSHv2 (remote configuration software replacement, monitoring) • Management: TR-069 protocol (for remote management and configuration, firmware updates Environment Operation/Storage temperature • from -35'C to +55'C, at 0 to 95 rel. humidity • from -40'C to +80'C, at 0 to 95 rel. humidity Construction Enclosure • IP51 plastic housing, sealable terminal cover, DIN-rail mounting supported • 16 status LEDs Dimensions/Weight • 150 x 150 x 58 mm / 310 gramms (with terminal cover) • 150 x 130 x 58 mm / 270 gramms (without terminal cover)

6. Legal notice

©2020. WM Systems LLC. The content of this documentation (all information, pictures, tests, descriptions, guides, logos) is under copyright protection. Copying, using, distributing and publishing is only permitted with the consent of WM Systems LLC., with clear indication of the source. The pictures in the user guide are only for illustration purposes. WM Systems LLC. does not take care the responsibility for any mistakes in the information contained in the user guide. The published information in this document is subject to change without notice. All data contained in the user guide is for information purposes only. For further information, please, contact our colleagues. Warning Any errors occurring during the program update process may result in failure of the device.