Wheatstone Evolution Series Technical Manual
Read Online
Read the Wheatstone Evolution Series Technical Manual online using the built-in PDF viewer.
Text of the manual
WHEATSTONE EVOLUTION SERIES
DIGITAL AUDIO NETWORK SYSTEM
600 Industrial Drive
New Bern, North Carolina 28562
tel 252-638-7000 / fax 252-637-1285
Wheatstone Evolution Series Digital Audio Network System - 2nd Edition
Wheatstone Evolution Series Digital Audio Network System - 2nd Edition
Wheatstone Evolution Series Digital Audio Network System - 2nd Edition
Wheatstone Evolution Series Digital Audio Network System - 2nd Edition
Wheatstone Evolution Series Digital Audio Network System - 2nd Edition
©2008 Wheatstone Corporation
page Contents – 1
E-Series Network / Apr 2007
C O N T E N T S
Wheatstone E-Series Digital
Audio Network System
Technical Manual
Table of Contents
Chapter 1 – General Information
Introduction ...................................................................................1-2
E-SAT E-Series Satellite Digital Network Router .......................1-3
E-Series Micro Satellite Digital Network Router.........................1-4
MCS-8 ....................................................................................................................... 1-4
MCS-8E .................................................................................................................... 1-5
Logic Connections ................................................................................................... 1-5a
Input Ports ......................................................................................................... 1-5a
Output Ports....................................................................................................... 1-5a
LOGIC Connector .............................................................................................. 1-5a
Internal Programming Options.................................................................................. 1-6
Switch Settings ................................................................................................... 1-6
S-16 E-WHEATNET- E-Series Audio Routing Switch Hub.........1-7
I/O Connections ........................................................................................................ 1-8
Audio Network ..................................................................................................... 1-8
AES Clock Sync................................................................................................... 1-8
Ethernet Interface ................................................................................................ 1-9
Typical Ethernet Cable ..................................................................................... 1-9
Typical Crossover Cable .................................................................................. 1-9
RJ-45 Connections Pinout Drawing ................................................................... 1-10
Front Panel LEDs .................................................................................................... 1-11
Internal Programming Options................................................................................. 1-11
Switch Settings Including Sample Rate ............................................................ 1-11
Jumper Settings ................................................................................................. 1-12
S-8 E-WHEATNET- E-Series Audio Routing Switch Hub..........1-13
I/O Connections ....................................................................................................... 1-14
Audio Network .................................................................................................... 1-14
AES Clock Sync.................................................................................................. 1-14
Ethernet Interface ............................................................................................... 1-15
RJ-45 Connections Pinout Drawing ................................................................... 1-16
Front Panel LEDs .................................................................................................... 1-17
Internal Programming Options................................................................................. 1-17
Switch Settings Including Sample Rate ............................................................ 1-17
Jumper Settings ................................................................................................. 1-18
E-Series Control Surfaces ...........................................................1-19
Ethernet-Based Controllers ........................................................1-20
Audio Connections ......................................................................1-22
Digital Audio Connections ....................................................................................... 1-2 2
Unbalanced Analog Connections ............................................................................ 1-22
Unbalanced Digital Connections (SPDIF) ............................................................... 1-22
Hand Crimp Tool Wiring Instructions ........................................1-24
E-Series Network / Nov 2008
!
All devices in the
system must be
set to the same
sample rate!
page Contents – 2
E-Series Network / Apr 2007
C O N T E N T S
Pin Extractor Instructions ...........................................................1-25
E-Series Digital Audio Netwok System Flow Diagram .............1-26
Chapter 2 – Hardware
Overview ........................................................................................2-3
Configuration Guidelines .............................................................2-3
Audio I/O Expansion ............................................................................................. 2-4
Digital Input Card (DI-NC4)
Overview ................................................................................................................... 2-5
AES Input Interface................................................................................................... 2-5
Hook-Ups .................................................................................................................. 2-6
DB Pinout Drawing ................................................................................................... 2-7
Analog Input Card (AI-NC4)
Overview ................................................................................................................... 2-8
Analog Input Interface .............................................................................................. 2-8
Internal Programming Options.................................................................................. 2-8
Hook-Ups .................................................................................................................. 2-9
Analog Audio Connections .................................................................................... 2-9
Mono Inputs ........................................................................................................ 2-9
DB Pinout Drawing .................................................................................................. 2-10
Digital Output Card (DO-NC4)
Overview .................................................................................................................. 2-11
AES Output Interface ............................................................................................... 2-11
AES Channel Status Implementation ...................................................................... 2-12
Internal Programming Options................................................................................. 2-12
Hook-Ups ................................................................................................................. 2-12
DB Pinout Drawing .................................................................................................. 2-13
Analog Output Card (AO-NC4)
Overview .................................................................................................................. 2-14
Analog Output Interface ........................................................................................... 2-14
Internal Programming Options................................................................................. 2-14
Hook-Ups ................................................................................................................. 2-15
Analog Audio Connections ................................................................................... 2-15
Mono Outputs .................................................................................................... 2-15
External Mono Summing ................................................................................... 2-16
DB Pinout Drawing .................................................................................................. 2-17
Logic I/O Card (LIO-NC4)
Overview .................................................................................................................. 2-18
Input Ports................................................................................................................ 2-18
Output Ports ............................................................................................................. 2-19
Typical Input/Output Circuit ..................................................................................... 2-19
Software Programming ............................................................................................ 2-20
Internal Programming Options................................................................................. 2-20
Dipswitch/Jumper Settings ...................................................................................... 2-20
Hook-Ups ................................................................................................................. 2-20
DB Pinout Drawing .................................................................................................. 2-22
Dual Audio Network Card (AT-NC2)
Overview .................................................................................................................. 2-23
Internal Programming Options................................................................................. 2-24
Switch Settings ........................................................................................................ 2-24
E-Series Network / Nov 2008
page Contents – 3
E-Series Network / Apr 2007
C O N T E N T S
Hook-Ups ................................................................................................................. 2-25
Typical CAT5 Cable .............................................................................................. 2-25
RJ-45 Pinout Drawing .............................................................................................. 2-26
Digital Signal Processor Card (DSP-NC)
Overview .................................................................................................................. 2-27
Internal Programming Options................................................................................. 2-27
Hook-Ups ................................................................................................................. 2-28
Typical CAT5 Cable .......................................................................................... 2-28
RJ-45 Pinout Drawing .............................................................................................. 2-29
Chapter 3 – XPoint Software Setup Guide
E-WHEATNET Ethernet/IP Address Quick Start.........................3-3
Ethernet Cabling ....................................................................................................... 3-3
Default IP Address .................................................................................................... 3-3
Changing your PC’s IP Address ............................................................................... 3-3
Changing the E-WHEATNET’s IP Address .............................................................. 3-4
Configuring IP Address in X-Point Software ............................................................ 3-4
Saving the System Configuration ............................................................................. 3-4
Getting Started ..............................................................................3-5
Basic System Requirements ........................................................3-5
GUI Log-In ......................................................................................3-6
Password .................................................................................................................. 3-6
Connecting E-WHEATNET and XPoint........................................3-6
IP Addressing ................................................................................3-7
System Configuration Menus ......................................................3-7
Tier Configuration ..................................................................................................... 3-8
E-WHEATNET Rack Configuration .......................................................................... 3-9
Surface Setup ........................................................................................................... 3-9
E-SAT Rack Configuration ...................................................................................... 3-10
Visibillity Settings ..................................................................................................... 3-11
VDip Settings ........................................................................................................... 3-12
Line Gain.................................................................................................................. 3-13
Microphone Gain ..................................................................................................... 3-13
Mix Minus Polarity.................................................................................................... 3-13
Password Modes ..................................................................................................... 3-13
Programmable Buttons ............................................................................................ 3-14
Connection Between the Config. GUI and E-WHEATNET ........3-15
Signal Definition ...........................................................................3-18
Configuring Logic I/O ..................................................................3-19
Overview .................................................................................................................. 3-19
Routable Logic ......................................................................................................... 3-19
Triggered Port Logic ................................................................................................ 3-19
Routable Logic Signal Definitions ............................................................................ 3-20
Defining Routable Logic Functions.......................................................................... 3-21
Viewing Defined Logic Signals ................................................................................ 3-21
Configured Triggered Port Logic ............................................................................. 3-22
E-Series Network / Jan 2008
page Contents – 4
E-Series Network / Apr 2007
C O N T E N T S
Signal Locking..............................................................................3-23
Salvo Definition ............................................................................3-24
Main Menu Summary ...................................................................3-25
File Menu ................................................................................................................. 3-25
User Menu ............................................................................................................... 3-25
Configure Menu ....................................................................................................... 3-25
View Menu ............................................................................................................... 3-26
Help Menu................................................................................................................ 3-26
Diagnostics Menu .................................................................................................... 3-26
Diagnostics Menu Examples ................................................................................... 3-27
Chapter 4 - I/O Schematic Drawings
4 Analog Inputs Network I/O Center (AINC-4)
Schematic ................................................................................................................. 4-2
Load Sheet................................................................................................................ 4-4
4 Analog Outputs Network I/O Center (AONC-4)
Schematic ................................................................................................................. 4-5
Load Sheet................................................................................................................ 4-7
4 Digital Inputs Network I/O Center (DINC-4)
Schematic ................................................................................................................. 4-8
Load Sheet............................................................................................................... 4-10
4 Digital Outputs Network I/O Center (DONC-4)
Schematic ................................................................................................................ 4-11
Load Sheet............................................................................................................... 4-12
Logic Interface Network I/O Center (LIONC-12)
Schematic ................................................................................................................ 4-13
Load Sheet............................................................................................................... 4-15
Dual Audio Transport Network I/O Center (ATNC-2)
Schematic ................................................................................................................ 4-16
Load Sheet............................................................................................................... 4-18
Digital Signal Processor Card (DSP-NC)
Load Sheet............................................................................................................... 4-19
SAT-E Mother Board (MBNC-1)
Schematic ................................................................................................................ 4-20
Load Sheet............................................................................................................... 4-21
S-16 Wheatnet-E Super Hub Main Card (IB-1)
Load Sheet............................................................................................................... 4-22
S-16 Wheatnet-E Super Hub LED Card (IBEL-1)
Load Sheet............................................................................................................... 4-23
S-8 Wheatnet-E Super Hub Main Card (IBA-1)
Load Sheet............................................................................................................... 4-24
Micro Satellite Main Card (MCS-8 & MCS-8E)
Load Sheet............................................................................................................... 4-25
E-Series Network / Jan 2008
page Contents – 5
E-Series Network / Apr 2007
C O N T E N T S
Glossary
Terminology.................................................................................. G-1
Appendices
Appendix 1
Configuring System IP Addresses ............................................. A-3
Overview ................................................................................................................... A-3
Editing Network Parameters ..................................................................................... A-3
Setting up FTP Site Profiles ................................................................................ A-3
Editing the Network Text Files............................................................................. A-4
Sample E-WHEATNET CPU Network File .......................................................... A-4
Surface Network Files ......................................................................................... A-4
Appendix 2
S-16 E-WHEATNET Replacement Parts List .............................. A-6
S-8 E-WHEATNET Replacement Parts List ................................ A-7
E-SAT Replacement Parts List.................................................... A-8
MCS-8 Replacement Parts List ................................................... A-9
MCS-8E Replacement Parts List ................................................ A-10
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 1
E-Series Network / Apr 2007
General Information
Chapter Contents
Introduction ................................................................................ 1-2
E-SAT E-Series Satellite Digital Network Router .................... 1-3
E-Series Micro Satellite Digital Network Router...................... 1-4
MCS-8 ..................................................................................................................... 1-4
MCS-8E .................................................................................................................. 1-5
Logic Connections ................................................................................................ 1-5a
Input Ports ...................................................................................................... 1-5a
Output Ports.................................................................................................... 1-5a
LOGIC Connector ........................................................................................... 1-5a
Internal Programming Options................................................................................ 1-6
Switch Settings ................................................................................................. 1-6
S-16 E-WHEATNET- E-Series Audio Routing Switch Hub...... 1-7
I/O Connections ...................................................................................................... 1-8
Audio Network ................................................................................................... 1-8
AES Clock Sync................................................................................................. 1-8
Ethernet Interface .............................................................................................. 1-9
Typical Ethernet Cable ................................................................................... 1-9
Typical Crossover Cable ................................................................................ 1-9
RJ-45 Connections Pinout Drawing ................................................................ 1-10
Front Panel LEDs ................................................................................................. 1-11
Internal Programming Options.............................................................................. 1-11
Switch Settings Including Sample Rate ......................................................... 1-11
Jumper Settings .............................................................................................. 1-12
S-8 E-WHEATNET- E-Series Audio Routing Switch Hub...... 1-13
I/O Connections .................................................................................................... 1-14
Audio Network ................................................................................................. 1-14
AES Clock Sync............................................................................................... 1-14
Ethernet Interface ............................................................................................ 1-15
RJ-45 Connections Pinout Drawing ................................................................ 1-16
Front Panel LEDs ................................................................................................. 1-17
Internal Programming Options.............................................................................. 1-17
Switch Settings Including Sample Rate ......................................................... 1-17
Jumper Settings .............................................................................................. 1-18
E-Series Control Surfaces ....................................................... 1-19
Ethernet-Based Controllers .................................................... 1-20
Audio Connections .................................................................. 1-22
Digital Audio Connections .................................................................................... 1-2 2
Unbalanced Analog Connections ......................................................................... 1-22
Unbalanced Digital Connections (SPDIF) ............................................................ 1-22
Hand Crimp Tool Wiring Instructions .................................... 1-24
Pin Extractor Instructions ....................................................... 1-25
E-Series Digital Audio Netwok System Flow Diagram ......... 1-26
E-Series Network / Nov 2008
!
All devices in the
system must be
set to the same
sample rate!
G E N E R A L I N F O R M A T I O N
page 1 – 2
E-Series Network / Apr 2007
General Information
Introduction
The Wheatstone Evolution Series (E-Series) Digital Audio Network System is
comprised of several components interconnected via CAT links to achieve a very
cost effective networked audio system. Each studio operates independently, yet can
share all sources and mixes through the S-16 (S-8) E-Series Wheatnet Switch—
without traffic limitations, or machine control delays.
Start your system with a simple AES router with analog and/or digital inputs and
outputs. From there you can add logic I/O cards and scheduling software to
interface to your automation system. You can create a custom system that includes
up to sixteen E-Series Satellite (E-SAT) cages and to up to twelve digital E-series
control surfaces linked to the S-16 (S-8) E-Series Wheatnet Switch. Cages can be
separated by distances up to 100m (328’) with many studios connected to your
central rack room, providing shared resources, yet still permitting independently
functioning satellite studios, each with its own combination of analog and digital
input and output cards and connector modules specifically selected to suit a large
variety of gear. We also provide a full complement of Ethernet protocol remote
router control panels, as well as a complete family of plug-in modules that interface
the routing system to existing Wheatstone digital and analog stand-alone consoles.
Optional
User-Supplied
Hardware
E-WHEATNET
E-SAT
E-Series Surface
User-Supplied
Monitor
E-Series Surface
MICROSATELLITE
E-SAT
E-SAT
G E N E R A L I N F O R M A T I O N
page 1 – 3
E-Series Network / Apr 2007
E-SAT - E-Series Satellite Digital Network Router
Stereo I/O may be
split into indepen-
dent mono signals.
Use crossover
wire CAT5 or bet-
ter for all AT and
DSP links.
The E-SAT is a rackmount unit occupying two 19” wide rack spaces
(total height 3 1/2”) with 16” depth.
The E-SAT accepts up to 16 discrete stereo analog or AES-3/SPDIF
digital audio sources, and 16 stereo analog or digital outputs. Integral, high
quality Sample Rate Converters (SRCs) on the digital inputs resolve
sample rates up to 96kHz. The E-SAT may be fitted with up to 4 input
cards, 4 output cards, and 2 logic cards. Hardware is described in the next
chapter.
All audio input, output, and logic connections are made via DB-25
PCB-mounted connectors located on the rear of chassis. The factory
supplied hand crimping tool is used for all DB-25 connections to and from
the router (see instruction on page 1-24). There are also RJ-45 connectors
for audio network and ethernet connections. Cage-to-cage network con-
nections are made by UTP CAT5 crossover cables terminated with RJ-45
connectors.
Assuming the E-SAT is correctly rackmounted, you may now energize
it by connecting the factory supplied power cord to the rackmount unit and
then plugging it into the AC mains.
Front panel LED indicators AC LINE and DC PWR should light up to
indicate the presence of their respective voltages.
The LINK1 and LINK2 LEDs indicate a good connection to the
E-WHEATNET and optional MCS-8 (MCS-8 with Engine) MICROSAT
or IOC.
Note: To de-energize the E-SAT, unplug its AC cord from the AC
mains.
!
!
G E N E R A L I N F O R M A T I O N
page 1 – 4
E-Series Network / Apr 2007
E-Series Micro Satellite Digital Network Router
MCS-8
The MCS-8 is a rackmount unit occupying one 19” wide rack space (total height
1 3/4”) with 16” depth.
The MCS-8 accepts up to 8 discrete stereo analog or AES-3/SPDIF digital audio
sources, and 8 stereo analog or digital outputs. Integral, high quality SRCs on the
digital inputs resolve sample rates up to 96kHz. The MCS-8 may be fitted with up to
2 input cards, and 2 output cards. It uses the same input/output card family as the
E-SAT and is pre-configured at the factory. Hardware is described in the next chapter.
All audio input and output connections are made via DB-25 PCB-mounted
connectors located on the rear of chassis. The factory supplied hand crimping tool is
used for all DB-25 connections to and from the router (see instruction on page 1-24).
There are also two RJ-45 connectors for audio network (“AT LINK” RJ-45—see
pages 1-8 and 1-10 for pinouts) and GPIO logic (LOGIC RJ-45) connections. See the
following section (page 1-5a) for logic details.
Cage-to-cage network connections can be made by UTP CAT5 crossover cables
terminated with RJ-45 connectors (see page 1-9 for pinouts).
Assuming the MCS-8 is correctly rackmounted, you may now energize it by
connecting the factory supplied power cord to the rackmount unit and then plugging
it into the AC mains.
Front panel LED indicators AC PWR and DC PWR should light up to indicate the
presence of their respective voltages.
The LINK1 LED indicates a good connection to the S-16 E-WHEATNET. Use
of the LINK2 LED is reserved.
Note: To de-energize the MCS-8, unplug its AC cord from the AC mains.
E-Series Network / Nov 2008
G E N E R A L I N F O R M A T I O N
page 1 – 5
E-Series Network / Apr 2007
MCS-8E
The MCS-8E is a rackmount unit occupying one 19” wide rack space (total
height 1 3/4”) with 16” depth.
The MCS-8E accepts up to 8 discrete stereo analog or AES-3/SPDIF digital
audio sources, and 4 stereo analog or digital outputs. Integral, high quality SRCs
on the digital inputs resolve sample rates up to 96kHz. The MCS-8E may be
fitted with up to 2 input cards, and one output card. It uses the same input/output
card family as the E-SAT and is pre-configured at the factory. Hardware is
described in the next chapter.
This unit also has a mix engine DSP that combines all of the console audio
signals as directed by a console’s faders, knobs, and switches to produce the
various Program, Aux Send, Mix Minus, and Monitor output mixes. The DSP
receives instructions from control surfaces in real time over a Mixer Transport
using the “MIXER LINK” RJ-45 connector on the rear panel (see pages 2-28
and 2-29 for pinouts).
All audio input and output connections are made via DB-25 PCB-mounted
connectors located on the rear of chassis. The factory supplied hand crimping
tool is used for all DB-25 connections to and from the router (see instruction on
page 1-24).
There are also two RJ-45 connectors for audio network (AT LINK RJ-45—
see pages 1-8 and 1-10 for pinouts) and GPIO logic connections. See the
following section (page 1-5a) for logic details.
E-Series Network / Nov 2008
G E N E R A L I N F O R M A T I O N
page 1 – 6
E-Series Network / Apr 2007
Logic Connections
Input Ports
If a logic port is configured as an input (see settings for SW7
and SW8), the logic common setting for that port (SW4 and
SW5) must be Common Plus. A simple closure between the
logic port pin and GROUND (pin 1) is then all that is required
to activate the input port.
Output Ports
If a logic port is configured as an output (see settings for
SW7 and SW8), then the logic common setting for that port
(SW4 and SW5) can be Common Plus or Common Ground, depending on the
application. The logic port is configured as a FET output, with one side of the
FET connected to the logic port pin and other side of the FET connected to
GROUND (Common Ground, for an active low output) or 5V through an
internal pullup resistor (Common Plus, for an active high output). Activating
the logic output port simply creates a closure between the logic port pin and
GROUND (Common Ground) or +5V (Common Plus).
“LOGIC” CONNECTOR
Pin 1 – GROUND
Pin 2 – LOGIC PORT 1
Pin 3 – LOGIC PORT 2
Pin 4 – LOGIC PORT 3
Pin 5 – LOGIC PORT 4
Pin 6 – LOGIC PORT 5
Pin 7 – LOGIC PORT 6
Pin 8 – +5V
page 1 – 5a
EXT
+5V
MCS-8
SIMPLE INPUT EXAMPLE
INPUT PORT
SWITCH
+5V
N/C
PORT
GND
E-Series Network / Nov 2008
G E N E R A L I N F O R M A T I O N
page 1 – 7
E-Series Network / Apr 2007
Internal Programming Options
All internal programming options are made via PCB mounted switches.
Switch Settings
SW1 - AT Reset
Momentarily pressing the switch resets the AT board LAN chip, while
pressing and holding the switch also resets the FPGA.
The recessed SW1 is accessible from the rear and is located next to the
“AT LINK” / “LOGIC” RJ-45 connectors.
SW2 - DSP Reset
Momentarily pressing the switch resets the DSP board LAN chip, while
pressing and holding the switch also resets the FPGA.
If loaded the recessed SW2 is accessible from the rear and is located next to the
“MIXER LINK” RJ-45 connector.
Dipswitch SW4, SW5 - Logic Common Plus / Common Ground
Dipswitch SW7, SW8 - Logic IN /OUT
The SW4 and SW5 switches are used in setting up logic in conjunction with
SW7 and SW8.
For Input Logic the corresponding switches should be set for Logic In and
Common Plus.
For Output Logic Active Low the corresponding switches should be set for
Logic Out and Common GND.
For Output Logic Active High (+5V) the corresponding switches should be set
for Logic Out and Common Plus.
For corresponding switches follow the 1 - 6 markings on the board.
Common Plus/Common Ground can be configured for each port individually.
Dipswitch SW6
Pos. 1 - Sample Rate Select - 48kHz when ON, 44.1kHz when OFF.
Pos. 2 - Remote Rack -
ON - this is a remote rack, therefore it is connected to another rack and is
designated as Rack 5 of the Tier in which the connected rack is located.
OFF - this is not a remote rack and will be configured as Rack 1.
Pos. 3 - Disables Remote Rack -
ON - a remote rack is not connected.
OFF - a remote rack is connected.
Pos. 4 - This switch is used in configuration and should be in the ON position.
SW9 and SW11 - Not Used
E-Series Network / Nov 2008
page 1 – 6
G E N E R A L I N F O R M A T I O N
page 1 – 7
E-Series Network / Apr 2007
S-16 E-WHEATNET - E-Series Audio Routing Switch
CAT5 Wiring Tip
S-16 E-WHEATNET is the high speed central network switch that
connects up to sixteen studios from the technical operations center. S-16
E-WHEATNET is capable of simultaneously switching 64 bi-directional
audio channels to 16 ports — that’s 2048 traffic channels.
This unit occupies one 19” wide rack unit (height 1 3/4”), and is 13”
deep.
Front panel LED indicators display system status, sample rate, and
external clock functions. No external PC is required for continuous
operation.
The sixteen rear mounted RJ-45 audio network ports easily integrate
multiple studio systems. Installation is simple: run one UTP CAT5
crossover cable to the E-WHEATNET from each of your studios or locally
mounted I/O centers.
Another wiring option is to run a UTP CAT5 straight connection from
the rack room to a small RJ-45 patch point block in each studio. The final
connection to each E-SAT rack or control surface can then be made using
an off the shelf crossover patch cable.
Power up Sequence — When first powering the system it is best to apply
Power up Sequence — When first powering the system it is best to apply
Power up Sequence — When first powering the system it is best to apply
Power up Sequence — When first powering the system it is best to apply
Power up Sequence — When first powering the system it is best to apply
power to the
power to the
power to the
power to the
power to the S-16
S-16
S-16
S-16
S-16 E-WHEATNET first, then E-SAT racks, and finally the
E-WHEATNET first, then E-SAT racks, and finally the
E-WHEATNET first, then E-SAT racks, and finally the
E-WHEATNET first, then E-SAT racks, and finally the
E-WHEATNET first, then E-SAT racks, and finally the
surface. You may cycle power on surfaces or E-SAT as required after the
surface. You may cycle power on surfaces or E-SAT as required after the
surface. You may cycle power on surfaces or E-SAT as required after the
surface. You may cycle power on surfaces or E-SAT as required after the
surface. You may cycle power on surfaces or E-SAT as required after the
S-16
S-16
S-16
S-16
S-16 E-WHEATNET is up and running.
E-WHEATNET is up and running.
E-WHEATNET is up and running.
E-WHEATNET is up and running.
E-WHEATNET is up and running.
E-Series Network / Jan 2008
!
G E N E R A L I N F O R M A T I O N
page 1 – 8
E-Series Network / Apr 2007
I/O Connections
All audio network, master clock, and Ethernet connections are made via
RJ-45 connectors mounted on the rear panel. The pinout drawings on page
1-10 summarize all wiring connections.
Audio Network
AT cards installed in E-SAT racks are connected to S-16 E-WHEATNET
via CAT5 crossover cables. For typical CAT5 cable pinouts, see page 1-9.
“1”-”16” CONNECTOR
Pin 1 – TX +
Pin 2 – TX -
Pin 3 – RX +
Pin 6 – RX -
AES Clock Sync
The S-16 E-WHEATNET Network system’s sample rate is normally
derived from its own internal crystal oscillator. The AES Clock sync
connector provides a means for synchronizing the Network system to an
external AES-11 master clock signal in the rare case that plant wide
synchronization is required. The fact that all digital inputs are fitted with
high quality sample rate converters obviates the need for external sync in
most cases.
“CLK” Connector
To sync your S-16 E-WHEATNET to an external AES Black clock
source use the AES Sync IN port available on the “CLK” RJ-45 connector:
Pin 1 – AES SYNC OUT HI
Pin 2 – AES SYNC OUT LO
Pin 3 – AES SYNC IN HI
Pin 6 – AES SYNC IN LO
Valid sample rates are 44.1kHz and 48kHz. EXT sync must match the
internal crystal setting. When sync is detected the front panel EXT LED will
light. Use only a high grade Digital Audio Reference Signal (DARS) per the
AES-11 specification.
AES Clock is a stan-
dard AES-3 output
without audio.
E-Series Network / Nov 2007
E-Series Network / Jan 2008
!
G E N E R A L I N F O R M A T I O N
page 1 – 9
E-Series Network / Apr 2007
Ethernet Interface
Connect the S-16 E-WHEATNET to your Ethernet LAN with a
straight (pin to pin) CAT5 cable. The LAN connection is for communicat-
ing with computers running Wheatstone software such as XPoint, PC-
XYC, and Event Computer. If you are connecting directly between the
computer and the S-16 E-WHEATNET with no network in between, use
a crossover cable. Typical straight and crossover CAT5 cable pinouts are
shown below.
“ETH” CONNECTOR
Pin 1 – TXD +
Pin 2 – TXD -
Pin 3 – RXD +
Pin 6 – RXD -
TYPICAL ETHERNET CABLE
TYPICAL CROSSOVER CABLE
1
2
3
4
TXD +
TXD -
RXD +
RXD -
PIN
1
2
3
4
PIN
RJ-45
Plug
RJ-45
Plug
White/Orange
5
6
7
8
N/C
N/C
5
6
7
8
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
N/C
N/C
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
1
2
3
4
TXD +
TXD -
RXD +
RXD -
PIN
1
2
3
4
PIN
RJ-45
Plug
RJ-45
Plug
White/Orange
5
6
7
8
N/C
N/C
5
6
7
8
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
N/C
N/C
RXD +
RXD -
TXD +
TXD -
N/C
N/C
N/C
N/C
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 10
E-Series Network / Apr 2007
1
2
3
4
5
6
7
8
TXD +
TXD -
RXD +
RXD -
"ETH"
RJ-45
Ethernet - RJ-45
RJ-45 Connections
1
2
3
4
5
6
7
8
TX +
TX -
RX +
RX -
"1"-"16"
RJ-45
Audio Network
1
2
3
4
5
6
7
8
AES SYNC OUT HI
AES SYNC OUT LO
AES SYNC IN HI
AES SYNC IN LO
"CLK"
RJ-45
AES Clock SYNC
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 11
E-Series Network / Apr 2007
Front Panel LEDs
On the left-lower part of the front panel there are five LEDs, that
function as follows.
EXT
The “EXT” LED lights up when an external AES reference clock
source is connected to the S-16 E-WHEATNET.
48K or 44.1K Sample Rate
Indicates the internally selected system sample rate, “48K” or “44.1K”.
Note that all S-16 E-WHEATNET devices must operate at the same
sample rate. Please consult the factory before changing sample rate.
On Line
The “ON LINE” LED lights when the S-16 E-WHEATNET CPU has
booted and is ready for use.
Error
In the unlikely event of an S-16 E-WHEATNET CPU failure the
“ERROR” LED will light up.
Internal Programming Options
All internal programming options are made via PCB mounted
dipswitches and jumpers.
Switch Settings
SW1 - CPU Reset
This momentary pushbutton switch allows the CPU to be reset without
powering down the system. Holding the button for two seconds will also
cause the FPGA program to be reloaded, first breaking all audio crosspoints.
Upon re-boot completion, the CPU will remake all system crosspoints.
The recessed SW1 is accessible from the rear and is located next to the
ETHERNET port.
E-Series Network / Jan 2008
!
All devices in the
system must be
set to the same
sample rate!
G E N E R A L I N F O R M A T I O N
page 1 – 12
E-Series Network / Apr 2007
DIPSW2
Pos.1 (labeled DIPSWØ on the circuit board) - 48/44.1 Sample Rate -
Off = 44.1K, On = 48K
Pos.2 - reserved - never ON
Pos.3 - reserved - never ON
Pos.4 - PRI/SEC select - OFF = Primary, ON = Redundant (not used)
Jumper Settings
J1 - CPU I/O PGRM
Momentary shorting will reload the CPU FPGA program.
J2 - PBRST
Factory Use Only
E-Series Network / Jan 2008
!
All devices in the
system must be
set to the same
sample rate!
G E N E R A L I N F O R M A T I O N
page 1 – 13
E-Series Network / Apr 2007
CAT5 Wiring Tip
S-8 E-WHEATNET - E-Series Audio Routing Switch
S-8 E-WHEATNET is the high speed central network switch that
connects up to eight studios from the technical operations center. E-
WHEATNET is capable of simultaneously switching 64 bi-directional
audio channels to 8 ports —that’s 1024 traffic channels.
This unit occupies one 19” wide rack unit (height 1 3/4”), and is 13”
deep.
Front panel LED indicators display system status, sample rate, and
external clock functions. No external PC is required for continuous opera-
tion.
The eight rear mounted RJ-45 audio network ports easily integrate
multiple studio systems. Installation is simple: run one UTP CAT5 cross-
over cable to the S-8 E-WHEATNET from each of your studios or locally
mounted I/O centers.
Another wiring option is to run a UTP CAT5 straight connection from
the rack room to a small RJ-45 patch point block in each studio. The final
connection to each E-SAT rack or control surface can then be made using
an off the shelf crossover patch cable.
Power up Sequence — When first powering the system it is best to apply
Power up Sequence — When first powering the system it is best to apply
Power up Sequence — When first powering the system it is best to apply
Power up Sequence — When first powering the system it is best to apply
Power up Sequence — When first powering the system it is best to apply
power to the S-8 E-WHEATNET first, then E-SAT racks, and finally the
power to the S-8 E-WHEATNET first, then E-SAT racks, and finally the
power to the S-8 E-WHEATNET first, then E-SAT racks, and finally the
power to the S-8 E-WHEATNET first, then E-SAT racks, and finally the
power to the S-8 E-WHEATNET first, then E-SAT racks, and finally the
surface. You may cycle power on surfaces or E-SAT as required after the
surface. You may cycle power on surfaces or E-SAT as required after the
surface. You may cycle power on surfaces or E-SAT as required after the
surface. You may cycle power on surfaces or E-SAT as required after the
surface. You may cycle power on surfaces or E-SAT as required after the
S-8 E-WHEATNET is up and running.
S-8 E-WHEATNET is up and running.
S-8 E-WHEATNET is up and running.
S-8 E-WHEATNET is up and running.
S-8 E-WHEATNET is up and running.
E-Series Network / Jan 2008
!
G E N E R A L I N F O R M A T I O N
page 1 – 15
E-Series Network / Apr 2007
AES Clock is a stan-
dard AES-3 output
without audio.
I/O Connections
All audio network, master clock, and Ethernet connections are made via
RJ-45 connectors mounted on the rear panel. The pinout drawings on page
1-16 summarize all wiring connections.
Audio Network
AT cards installed in E-SAT racks are connected to S-8 E-WHEATNET
via CAT5 crossover cables. For typical CAT5 cable pinouts, see page 1-9.
“1”-”8” CONNECTOR
Pin 1 – TX +
Pin 2 – TX -
Pin 3 – RX +
Pin 6 – RX -
AES Clock Sync
The S-8 E-WHEATNET Network system’s sample rate is normally
derived from its own internal crystal oscillator. The AES Clock sync
connector provides a means for synchronizing the Network system to an
external AES-11 master clock signal in the rare case that plant wide
synchronization is required. The fact that all digital inputs are fitted with
high quality sample rate converters obviates the need for external sync in
most cases.
“CLK” Connector
To sync your S-8 E-WHEATNET to an external AES Black clock
source use the AES Sync IN port available on the “CLK” RJ-45 connector:
Pin 1 – AES SYNC OUT HI
Pin 2 – AES SYNC OUT LO
Pin 3 – AES SYNC IN HI
Pin 6 – AES SYNC IN LO
Valid sample rates are 44.1kHz and 48kHz. EXT sync must match the
internal crystal setting. When sync is detected the front panel EXT LED will
light. Use only a high grade Digital Audio Reference Signal (DARS) per the
AES-11 specification.
E-Series Network / Jan 2008
!
page 1 – 14
G E N E R A L I N F O R M A T I O N
page 1 – 15
E-Series Network / Apr 2007
Ethernet Interface
Connect S-8 E-WHEATNET to your Ethernet LAN with a straight (pin to
pin) CAT5 cable. The LAN connection is for communicating with computers
running Wheatstone software such as XPoint, PC-XYC, and Event Computer.
If you are connecting directly between the computer and the S-8 E-WHEATNET
with no network in between, use a crossover cable. Typical straight and
crossover CAT5 cable pinouts are shown on page 1-9.
“ETH” CONNECTOR
Pin 1 – TXD +
Pin 2 – TXD -
Pin 3 – RXD +
Pin 6 – RXD -
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 16
E-Series Network / Apr 2007
1
2
3
4
5
6
7
8
TXD +
TXD -
RXD +
RXD -
"ETH"
RJ-45
Ethernet - RJ-45
RJ-45 Connections
1
2
3
4
5
6
7
8
TX +
TX -
RX +
RX -
"1"-"8"
RJ-45
Audio Network
1
2
3
4
5
6
7
8
AES SYNC OUT HI
AES SYNC OUT LO
AES SYNC IN HI
AES SYNC IN LO
"CLK"
RJ-45
AES Clock SYNC
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 17
E-Series Network / Apr 2007
Front Panel LEDs
On the right-lower part of the front panel there are five LEDs, that function
as follows.
EXT
The “EXT” LED lights up when an external AES reference clock source
is connected to the S-8 E-WHEATNET.
48K or 44.1K Sample Rate
Indicates the internally selected system sample rate, “48K” or “44.1K”.
Note that all S-8 E-WHEATNET devices must operate at the same sample
rate. Please consult the factory before changing sample rate.
On Line
The “ON LINE” LED lights when the S-8 E-WHEATNET CPU has
booted and is ready for use.
Error
In the unlikely event of a S-8 E-WHEATNET CPU failure the “ERROR”
LED will light up.
Internal Programming Options
All internal programming options are made via PCB mounted dipswitches
and jumpers.
Switch Settings
SW1 - CPU Reset
This momentary pushbutton switch allows the CPU to be reset without
powering down the system. Holding the button for two seconds will also cause
the FPGA program to be reloaded, first breaking all audio crosspoints. Upon
re-boot completion, the CPU will remake all system crosspoints.
The recessed SW1 is accessible from the rear and is located next to the
ETHERNET port.
E-Series Network / Jan 2008
!
All devices in the
system must be
set to the same
sample rate!
G E N E R A L I N F O R M A T I O N
page 1 – 18
E-Series Network / Apr 2007
DIPSW3
Pos.1 (labeled DIPSWØ on the circuit board) - 48/44.1 Sample Rate -
Off = 44.1K, On = 48K
Pos.2 - reserved - never ON
Pos.3 - reserved - never ON
Pos.4 - PRI/SEC select - OFF = Primary, ON = Redundant (not used)
Jumper Settings
J1 - CPU I/O PGRM
Momentary shorting will reload the CPU FPGA program.
J2 - PBRST
Factory Use Only
E-Series Network / Jan 2008
!
All devices in the
system must be
set to the same
sample rate!
G E N E R A L I N F O R M A T I O N
page 1 – 19
E-Series Network / Apr 2007
E-Series Control Surfaces
Designed to integrate flawlessly with the E-series Satellite digital
audio network router, the E-series control surfaces allow you to easily
create large- or small- platform-based systems that are exceptionally user-
friendly and flexible. They will handle your most demanding require-
ments, and be able to change with your varying needs as they arise. You
can select any combination of input signals in the entire E-Series system
and create a multitude of mixes from them. Onboard routing control allows
all these mixes to be directed to any destination in your facility. Powerful
built-in equalization and gain reduction circuits let you tame and sweeten
any signal you come across. An RJ-45 Audio Transport “MIXER”
connector on the rear of the control surface serves as the link between the
surface and the network system. Operation of the control surfaces is
covered in the specified separate Technical Manual.
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 20
E-Series Network / Apr 2007
Ethernet-Based Controllers
A family of Ethernet-based controllers provides an integrated way of switch-
ing Digital Audio Router sources to destinations connected to the console.
Rackmount and modular versions of the Ethernet based controllers are available.
Mount the Ethernet based controller modules into existing Audioarts’s stand-
alone analog or digital mixing consoles. Choose from eight or sixteen button
source selectors, dual source select panels, or single and dual X-Y panels.
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 21
E-Series Network / Apr 2007
All X-Y crosspoint controllers have similar functions. First, select a DESTINATION
(console fader, recorder, etc.) by turning the DESTINATION knob. By turning the
SOURCE knob, the available inputs are displayed in the 8-character display window and
the TAKE button lights. When the desired input source is scrolled into the display window,
pressing the TAKE button will execute the take command on the downstroke. The TAKE
button light goes off and the desired input source is selected. Note that if the TAKE button
is not pressed in a timeout period of 6-8 seconds, the display will revert to its previous setting.
Some controllers have PROGRAMMABLE buttons to program input sources. To
program the desired input source for a selected button, press the button and hold it for a few
seconds. The display window will displayed , and the desired input source will
be stored for this button.
When the SOURCE knob is scrolled to a programmed input source, the associated button
lights to indicate the correspondence between the source and button.
The Ethernet-Based Controllers connect to your LAN via standard UTP CAT5 “straight”
cables terminated with RJ-45 connectors.
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 22
E-Series Network / Apr 2007
Audio Connections
All audio connections to the E-SAT and MICROSAT are made through
multipin DB-25 connectors located on the rear of the chassis.
The factory supplied hand crimping tool is used for all DB-25 style
wiring connections (see instruction on the page 1-24).
Digital Audio Connections
CABLE - All AES/EBU input and output digital audio connections are
balanced and should be made using a high quality digital audio cable. Be
sure to select a digital audio cable with an integral drain wire of the same
wire gauge (AWG) as the twisted pair as this facilitates an easier and
consistent termination process. Typical AES/EBU digital audio cable has
a very low characteristic capacitance per ft (pF/ft), and a nominal imped-
ance of 110 ohm. High quality digital audio cable offers better signal
transmission performance versus typical analog audio cable, especially
over long cable runs. Check the cable manufacturer’s data sheet to be sure
the cable you plan to use will work in your application.
CONNECTORS - Typically, all AES/EBU connections are made with
the supplied DB-25 male mating connectors. These crimp style connectors
will accept wire gauge 22 - 28AWG.
Unbalanced Analog Connections
ANALOG INPUTS — Wire to the switcher input end with typical
shielded, two conductor cable (like Belden 9451), just as if you were
connecting a balanced source. At the unbalanced source machine’s output,
connect the + output to the HI input wire and connect the source machine
GND wire to LO; connect the shield at the balanced end only.
Note: Unbalanced analog sources typically have -10dBv (316mV RMS)
signal levels and will not match the E-SAT and MICROSAT nominal
operating level of +4dBu (1.23V RMS). We highly recommended that you
first externally balance any unbalanced sources you plan on connecting to
the E-SAT and MICROSAT. Many third party “match boxes” are commer-
cially available for this.
ANALOG OUTPUTS — Use an electronically balanced output circuit
which behaves exactly like the secondary of a high-quality transformer,
with no center tap—this output is both balanced and floating. For unbal-
anced operation, either the HI or LO side of the analog output must be
strapped to ground of the unbalanced input, with the output taken from the
other side. (Normally you would strap LO to ground, and use HI to feed
your unbalanced equipment input.) Leave the SH floating at the unbalanced
end.
Unbalanced Digital Connections (SPDIF)
SPDIF INPUTS - The SPDIF (Sony/Phillips Digital Interface) or
“consumer” digital audio interface is a two wire unbalanced signal typically
on a single RCA style connector. We highly recommend using a “balun” or
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 23
E-Series Network / Apr 2007
format converter when interfacing “consumer” grade source devices to the
E-SAT.
In cases where a consumer grade device must be interfaced and the
appropriate matching device is not available, try wiring the SPDIF center
conductor (HOT) to the HI input pin and SPDIF shell (ground) to the LO
input. Connect SH at the E-SAT or MICROSAT end only. Keep cable
lengths to a minimum.
SPDIF OUTPUTS - The E-SAT and MICROSAT digital outputs are
fixed, professional, AES-3 formatted outputs. SPDIF consumer format is
not supported. Use of an external format converter may be required to
connect the digital outputs to consumer gear.
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 24
E-Series Network / Apr 2007
HAND CRIMP TOOL WIRING INSTRUCTIONS
The supplied hand crimping tool (W/S#850067) is used for all I/O wiring con-
nections to and from the console. It is to be used with the supplied pin (figure 1)
intended for 22"-28" gauge wire.
1) Strip wire approximately 3/16" (insert in
proper wire stripper, rotate one half turn, and
pull insulation off wire).
2) Leaving wire aside for the moment, with
crimping tool fully open (engraved side toward
you) bring a terminal into position from the
unmarked side of the tool. Place the conductor
tabs (inner set as shown in figure 1) on the
"18-22" or "24-30" (depending on the wire) an-
vil (slightly curved surface) so that the circular
portion of the tabs rests in the curved surface
of the anvil and the two tabs face up into the
walls of the female jaw. The insulation tabs will
be flush with the top of the tool (figure 2).
3) Close tool very slightly, only to the point
of holding the terminal in position (figure 2).
4) Insert wire into terminal until wire insu-
lation is stopped by conductor tabs (figure 3).
CRIMP by squeezing handles until jaws are fully
closed (figure 4).
5) If there is an insertion error or if a circuit
change is needed, you'll need to use an extrac-
tor tool to remove terminals (see next page).
Note that metallized plastic hoods for each
connector are also supplied with the router.
(1) Pin crimp terminal
CONDUCTOR
TABS
INSULATION
TABS
INSULATION
STOPS HERE
(2) The terminal conductor tabs (pointing UP) are
placed in anvil 18-22; the terminal's insulation tabs
extend in front towards the camera.
(3) The stripped wire is placed into the terminal and
crimped. Note the wire's insulation must stop just
short of the conductor tabs (detail)
(4) Final step: jaws fully closed; the insulation tabs
have been crimped.
Insulation
stops here
E-Series Network / Jan 2008
G E N E R A L I N F O R M A T I O N
page 1 – 25
E-Series Network / Apr 2007
(5) Place extractor tip over pin terminal to be
removed.
If you accidentally insert a crimp terminal
pin into the wrong socket, you'll need to use
the supplied pin extractor tool (W/S#850069)
to remove terminal pin, and correct your mis-
take without having to sacrifice a connector.
Place extractor tip (red side) over terminal pin
to be removed (figure 5), and press it down-
wards motion until tip rests upon Housing.
Then pull out the terminal pin from Housing.
It should never be necessary to discard a con-
nector due to a wiring error.
PIN EXTRACTOR INSTRUCTIONS
E-Series Network / Jan 2008
page 2 – 1
E-Series Network / Apr 2007
H A R D W A R E
Hardware
Chapter Contents
Overview ........................................................................................2-3
Configuration Guidelines .............................................................2-3
Audio I/O Expansion ............................................................................................. 2-4
Digital Input Card (DI-NC4)
Overview ................................................................................................................... 2-5
AES Input Interface................................................................................................... 2-5
Hook-Ups .................................................................................................................. 2-6
DB Pinout Drawing ................................................................................................... 2-7
Analog Input Card (AI-NC4)
Overview ................................................................................................................... 2-8
Analog Input Interface .............................................................................................. 2-8
Internal Programming Options.................................................................................. 2-8
Hook-Ups .................................................................................................................. 2-9
Analog Audio Connections .................................................................................... 2-9
Mono Inputs ........................................................................................................ 2-9
DB Pinout Drawing .................................................................................................. 2-10
Digital Output Card (DO-NC4)
Overview .................................................................................................................. 2-11
AES Output Interface ............................................................................................... 2-11
AES Channel Status Implementation ...................................................................... 2-12
Internal Programming Options................................................................................. 2-12
Hook-Ups ................................................................................................................. 2-12
DB Pinout Drawing .................................................................................................. 2-13
Analog Output Card (AO-NC4)
Overview .................................................................................................................. 2-14
Analog Output Interface ........................................................................................... 2-14
Internal Programming Options................................................................................. 2-14
Hook-Ups ................................................................................................................. 2-15
Analog Audio Connections ................................................................................... 2-15
Mono Outputs .................................................................................................... 2-15
External Mono Summing ................................................................................... 2-16
DB Pinout Drawing .................................................................................................. 2-17
Logic I/O Card (LIO-NC4)
Overview .................................................................................................................. 2-18
Input Ports................................................................................................................ 2-18
Output Ports ............................................................................................................. 2-19
Typical Input/Output Circuit ..................................................................................... 2-19
Software Programming ............................................................................................ 2-20
Internal Programming Options................................................................................. 2-20
Dipswitch/Jumper Settings ...................................................................................... 2-20
Hook-Ups ................................................................................................................. 2-20
DB Pinout Drawing .................................................................................................. 2-22
page 2 – 2
E-Series Network / Apr 2007
H A R D W A R E
Dual Audio Network Card (AT-NC2)
Overview .................................................................................................................. 2-23
Internal Programming Options................................................................................. 2-24
Switch Settings ........................................................................................................ 2-24
Hook-Ups ................................................................................................................. 2-25
Typical CAT5 Cable .............................................................................................. 2-25
RJ-45 Pinout Drawing .............................................................................................. 2-26
Digital Signal Processor Card (DSP-NC)
Overview .................................................................................................................. 2-27
Internal Programming Options................................................................................. 2-27
Hook-Ups ................................................................................................................. 2-28
Typical CAT5 Cable .......................................................................................... 2-28
RJ-45 Pinout Drawing .............................................................................................. 2-29
page 2 – 3
E-Series Network / Apr 2007
H A R D W A R E
Hardware
Overview
E-Satellite
The E-SAT may be configured in a variety of I/O card complements
using various combinations of analog and digital audio input and output
daughter cards. All audio input, output, and logic connections are made via
multipin DB-25 connectors located on the cage rear and mounted on the
daughter cards. The daughter cards plug into the E-SAT’s backplane
connectors.
MCS-8 Microsatellite
The MCS-8 unit may be fitted with up to 2 input card, and 2 output cards.
It uses the same input/output card family as the E-SAT and is pre-
configured at the factory.
Configuration Guidelines
While the E-SAT router is pre-configured at
Wheatstone’s factory, future expansion of a system may
require some re-configuration of existing hardware to
accommodate new resources.
Slots are numbered from 1 to 12, left to right, as
viewed from the rear of the cage. Each slot is configured
to support one type of card. Slots 1 and 2 may only contain
universal GPI/GPO logic cards. Slots 3 through 6 may
only contain audio input cards (analog or digital) and
slots 7 through 10 may only contain audio output cards
(analog or digital). Slot 11 may only contain a Digital
Signal Processor Card, and slot 12 may only contain a
Dual Audio Network Card.
page 2 – 4
E-Series Network / Apr 2007
H A R D W A R E
There are 12 ports on each logic card. Each logic card port may be
configured as an input or output via an internal dipswitch selection.
Analog and digital input and output cards each handle four stereo inputs/
outputs. The E-SAT can support up to four input cards and four output
cards, and digital and analog can be freely mixed. However, the card
complement can not exceed 16 inputs or 16 outputs.
Audio I/O Expansion
The E-SAT supports a maximum of 16 stereo input channels and 16
stereo output channels.
• Power down by removing AC cord.
• Removing the rear panel with input/output card or blank rear panel
- Remove the 2 - #4-40 x 3/16” Phillips head screws and pull the panel out
carefully using the thumb nut.
• Installing an audio card - Care must be taken when plugging in the
expansion card’s 36 pin ribbon connector. Be sure to match the connector
sockets to the motherboard header pins. Failure to do so will damage the
expansion card, ribbon cable, and/or motherboard.
!
page 2 – 5
E-Series Network / Apr 2007
H A R D W A R E
Digital Input Card (DI-NC4)
Overview
The DI-NC4 digital audio input cards for the E-SAT and MICROSAT
accept up to 4 AES-3 formatted stereo sources (i.e. 8 mono channels). An
Audio Configuration form in the supplied XPoint software allows the user to
set attributes for the input channels including signal name, location, and Stereo/
Mono. These signal attributes are pre-configured at the factory for stereo
operation.
Note: While it is possible to split the 4 stereo AES inputs into 8 mono channels,
there are still only 4 physical wires, each containing the 2-channel AES
formatted data.
A dedicated sample rate converter for each input re-clocks the incoming
audio data and phase locks it to the system’s master sample rate clock. Source
sample rates up to 96 kHz are supported.
AES Input Interface
The balanced digital audio inputs on the DI-NC4 card are transformer
coupled. AES receivers strip off the received sample rate clock and audio data
for further processing by sample rate converters. The balanced interface
operates at a nominal peak-to-peak input voltage of 5V with an input imped-
ance of 110 Ohm and conforms to the AES-3 1992 electrical specification.
Note that Channel Status data is not forwarded.
While unbalanced SPDIF formatted input signals may be connected to the
HI and LO inputs of an AES input channel (leave the shield floating), it is
recommended that a BALUN or other external matching device be inserted to
convert the SPDIF impedance to 110 Ohm with a signal level of at least 1V p-
p.
page 2 – 6
E-Series Network / Apr 2007
H A R D W A R E
Hook-Ups
All user wiring to the DI-NC4 card takes place at the female DB-25 I/O
connector on the cage rear.
DB-25—Digital Audio Connections
These include four input sources. Pinout drawing on page 2-8 shows all
wiring connections at a glance.
Pin 24 – HI
Pin 12 – LO AES 1 In
Pin 25 – SH
Pin 10 – HI
Pin 23 – LO AES 2 In
Pin 11 – SH
Pin 21 – HI
Pin 9 – LO AES 3 In
Pin 22 – SH
Pin 7 – HI
Pin 20 – LO AES 4 In
Pin 8 – SH
page 2 – 7
E-Series Network / Apr 2007
H A R D W A R E
DI-NC4 Panel
Digital Input Connections
AES 1 IN HI
AES 2 IN LO
AES 3 IN HI
AES 4 IN LO
N/C
N/C
N/C
N/C
N/C
N/C
AUDIO GROUND
AES 1 IN LO
AES 2 IN SH
AES 2 IN HI
AES 3 IN LO
AES 4 IN SH
AES 4 IN HI
N/C
N/C
N/C
N/C
N/C
N/C
5
4
3
2
1
17
16
15
14
8
7
6
20
19
18
10
9
23
22
21
13
12
11
25
24
AES 1 IN SH
AES 3 IN SH
DB-25
Input Ports
DIGITAL
INPUT
page 2 – 8
E-Series Network / Apr 2007
H A R D W A R E
Analog Input Card (AI-NC4)
Overview
The Analog input card accepts up to 4 stereo analog audio sources (i.e. 8
mono channels). An Audio Configuration form in the supplied XPoint
software allows the user to set attributes for the input channel hardware,
including signal name, location, and Stereo/Mono. The 8 input channels may
be configured as mono signals (one channel) or stereo signals (two channels)
in any combination.
The balanced, line level analog input signals are buffered and converted
to the digital domain by 24bit A-D converters operating at the system’s master
sample rate. Embedded logic routes each channel of audio data into an
available time slot of the input card’s TDM bus. One TDM bus is allocated for
each input card.
Analog Input Interface
The balanced analog input stages are direct coupled, unity gain circuits and
operate at a nominal input level of +4dBu. The input impedance is 20kOhm.
A +4dBu input signal will result in a -20dBFS digital output level at any of the
selected AES outputs. The maximum analog input signal level is +24 dBu
providing 20 dB of headroom above the nominal input level.
Reference Notes:
0dBu = .7746 V RMS, +4dBu = 1.23V RMS
dBFS = dB Full Scale Digital
-20dBFS = +4dBu
Internal Programming Options
There are no internal programming options on the AI-NC4 card.
page 2 – 9
E-Series Network / Apr 2007
H A R D W A R E
Hook-Ups
All user wiring to the AI-NC4 card takes place at the female DB-25
connector on the cage rear.
DB-25—Analog Audio Connections
These include four (1-4) input sources. Pinout drawing on page 2-11
shows all wiring connections at a glance.
Pin 24 – HI
Pin 12 – LO
Channel 1 In LT
Pin 25 – SH
Pin 10 – HI
Pin 23 – LO
Channel 2 In RT
Pin 11 – SH
Pin 21 – HI
Pin 9 – LO
Channel 3 In LT
Pin 22 - SH
Pin 7 – HI
Pin 20 – LO
Channel 4 In RT
Pin 8 – SH
Pin 18 – HI
Pin 6 – LO
Channel 5 In LT
Pin 19 – SH
Pin 4 – HI
Pin 17 – LO
Channel 6 In RT
Pin 5 – SH
Pin 15 – HI
Pin 3 – LO
Channel 7 In LT
Pin 16 – SH
Pin 1 – HI
Pin 14 – LO
Channel 8 In RT
Pin 2 – SH
Mono Inputs
Mono analog sources can be wired in two ways. If you maintain the
default stereo configuration, strap the mono source across both the left
and right sides of the stereo input. But if you reconfigure the stereo input
for two channel mono operation (please see the “Audio Configuration”
section in the “XPoint Software Setup Guide”) you can then wire one
mono source to the “left” input and a second mono source to the “right”
input.
Stereo 1 In
Stereo 2 In
Stereo 3 In
Stereo 4 In
page 2 – 10
E-Series Network / Apr 2007
H A R D W A R E
CHANNEL 1 (STEREO 1 LT) IN HI
CHANNEL 2 (STEREO 1 RT) IN LO
CHANNEL 3 (STEREO 2 LT) IN HI
CHANNEL 4 (STEREO 2 RT) IN LO
CHANNEL 5 (STEREO 3 LT) IN SH
CHANNEL 5 (STEREO 3 LT) IN HI
CHANNEL 6 (STEREO 3 RT) IN LO
CHANNEL 7 (STEREO 4 LT) IN SH
CHANNEL 7 (STEREO 4 LT) IN HI
CHANNEL 8 (STEREO 4 RT) IN LO
AUDIO GROUND
CHANNEL 1 (STEREO 1 LT) IN LO
CHANNEL 2 (STEREO 1 RT) IN SH
CHANNEL 2 (STEREO 1 RT) IN HI
CHANNEL 3 (STEREO 2 LT) IN LO
CHANNEL 4 (STEREO 2 RT) IN SH
CHANNEL 4 (STEREO 2 RT) IN HI
CHANNEL 5 (STEREO 3 LT) IN LO
CHANNEL 6 (STEREO 3 RT) IN SH
CHANNEL 6 (STEREO 3 RT) IN HI
CHANNEL 7 (STEREO 4 LT) IN LO
CHANNEL 8 (STEREO 4 RT) IN SH
CHANNEL 8 (STEREO 4 RT) IN HI
5
4
3
2
1
17
16
15
14
8
7
6
20
19
18
10
9
23
22
21
13
12
11
25
24
CHANNEL 1 (STEREO 1 LT) IN SH
CHANNEL 3 (STEREO 2 LT) IN SH
DB-25
Input Ports
AI-NC4 Panel
Analog Input Connections
ANALOG
INPUT
page 2 – 11
E-Series Network / Apr 2007
H A R D W A R E
Digital Output Card (DO-NC4)
Overview
Each Digital Output card provides 4 physical AES-3 formatted outputs.
An Audio Configuration form in the supplied XPoint software allows the
user to set attributes for the output channels, including signal name,
location, and Stereo/Mono. The 4 AES outputs are configured in software
at the factory to be stereo destinations.
Each output card listens for connection commands from the
E-WHEATNET CPU, and then uses this information to connect the
appropriate sources to their selected output channels. The selected audio
data is fed to AES transmitters which format the 24 bit audio data according
to the AES-3 standard.
Note: While it is possible to split the 4 stereo AES outputs into 8 mono
channels, there are still only 4 physical wires, each containing the
2-channel AES formatted data.
AES Output Interface
The balanced digital audio outputs on the DO-NC4 card are transformer
coupled and exhibit a nominal output impedance of 110 Ohm. This
interface operates at a nominal output voltage of 5V p-p and conforms to
the AES-3 1992 electrical specification. The DO-NC4 output cards operate
at unity gain and transmit 24bit audio data word lengths at the system
sample rate, which can be set to 44.1 kHz or 48 kHz. Optionally, the E-
WHEATNET External AES Sync input may be used to slave the system to
a user provided 44.1 kHz or 48 kHz reference rate. Please refer to the E-
WHEATNET hardware section for details on external synchronization.
The digital output signal reference level is -20dBFS. A +4dBu analog
input signal yields a -20dBFS digital output signal. Channel Status
implementation complies with rules for “standard implementation” as
described in the AES-3 1992 specification.
page 2 – 12
E-Series Network / Apr 2007
H A R D W A R E
AES Channel Status Implementation
The following embedded channel status information is transmitted at
the AES digital outputs along with the audio data.
Note: Channel Status bits are identically set for channels 1 and 2.
Internal Programming Options
There are no internal programming options on the DO-NC4 card.
Hook-Ups
All user wiring from the DO-NC4 card takes place at the female DB-25
connector on the cage rear.
Digital Audio Connections
These include four outputs. Pinout drawing on page 2-13 shows all
wiring connections at a glance.
Pin 24 – HI
Pin 12 – LO AES 1 Out
Pin 25 – SH
Pin 10 – HI
Pin 23 – LO AES 2 Out
Pin 11 – SH
Pin 21 – HI
Pin 9 – LO AES 3 Out
Pin 22 – SH
Pin 7 – HI
Pin 20 – LO AES 4 Out
Pin 8 – SH
CHANNEL STATUS:
PROFESSIONAL
DATA USE:
AUDIO (normal mode)
EMPHASIS:
NO EMPHASIS
SOURCE Fs LOCK:
LOCKED
SAMPLE FREQUENCY:
44.1 kHz or 48 kHz
CHANNEL MODE:
STEREO
USER BITS MODE:
NONE
AUX BITS USE:
24 BIT - main audio
AUDIO WORD LENGTH: 24 BIT
REFERENCE SIGNAL:
NOT A REFERENCE SIGNAL
ORIGIN:
NOT INDICATED
DESTINATION:
NOT INDICATED
SAMPLE #:
Ø
TIME OF DAY:
ØØ : ØØ : ØØ
BLOCK CRC:
IS VALID
page 2 – 13
E-Series Network / Apr 2007
H A R D W A R E
DO-NC4 Panel
Digital Output Connections
AES 1 OUT HI
AES 2 OUT LO
AES 3 OUT HI
AES 4 OUT LO
N/C
N/C
N/C
N/C
N/C
N/C
AUDIO GROUND
AES 1 OUT LO
AES 2 OUT SH
AES 2 OUT HI
AES 3 OUT LO
AES 4 OUT SH
AES 4 OUT HI
N/C
N/C
N/C
N/C
N/C
N/C
5
4
3
2
1
17
16
15
14
8
7
6
20
19
18
10
9
23
22
21
13
12
11
25
24
AES 1 OUT SH
AES 3 OUT SH
DB-25
Output Ports
DIGITAL
OUTPUT
page 2 – 14
E-Series Network / Apr 2007
H A R D W A R E
Analog Output Card (AO-NC4)
Overview
Each Analog Output card provides 8 physical monaural output channels.
These output channels are configured in software to be 4 stereo pairs.
An Audio Configuration form in the supplied XPoint software allows the user
to set attributes for the output channels, including signal name, location, and
Stereo/Mono.
Each output card listens for connection commands from the CPU and then
uses this information to connect the appropriate sources to their selected
output channels. The selected audio data is fed to 24 bit, two-channel digital-
to-analog converters. The D-A converter outputs are buffered by integrated
differential output drivers.
Analog Output Interface
Each balanced unity gain output will drive loads of 600 Ohm or above and
behaves much like a transformer in that either side of the balanced output may
be grounded. The analog outputs are direct coupled with an output impedance
of 50 Ohm and a nominal output signal level of +4dBu for an analog input
signal of +4dBu (-20dBFs digital) .
Internal Programming Options
There are no internal programming options on the AO-NC4 card.
page 2 – 15
E-Series Network / Apr 2007
H A R D W A R E
Hook-Ups
All user wiring from the AO-NC4 card takes place at the female DB-25
connector on the cage rear.
Analog Audio Connections
These include four outputs. Pinout drawing on page 2-17 shows all
wiring connections at a glance.
Pin 24 – HI
Pin 12 – LO
Channel 1 Out LT
Pin 25 – SH
Pin 10 – HI
Pin 23 – LO
Channel 2 Out RT
Pin 11 – SH
Pin 21 – HI
Pin 9 – LO
Channel 3 Out LT
Pin 22 - SH
Pin 7 – HI
Pin 20 – LO
Channel 4 Out RT
Pin 8 – SH
Pin 18 – HI
Pin 6 – LO
Channel 5 Out LT
Pin 19 – SH
Pin 4 – HI
Pin 17 – LO
Channel 6 Out RT
Pin 5 – SH
Pin 15 – HI
Pin 3 – LO
Channel 7 Out LT
Pin 16 – SH
Pin 1 – HI
Pin 14 – LO
Channel 8 Out RT
Pin 2 – SH
Mono Outputs
There are two ways to adapt the E-SAT and MICROSAT for mono
operation. Externally sum a stereo output using 1kOhm resistors, or
reconfigure the output in software for mono operation. Please see the
“XPoint Audio Configuration” for details on configuring mono outputs.
Caution! If you route a stereo input to a software configured mono
output, only one output channel will be present.
Stereo 1 Out
Stereo 2 Out
Stereo 3 Out
Stereo 4 Out
page 2 – 16
E-Series Network / Apr 2007
H A R D W A R E
External Mono Summing
To sum an E-SAT or MICROSAT stereo analog output add a
1kOhm resistor in series with each leg of the balanced output. Add
resistors as close as possible to the mono input.
Example:
+
+
+
+
LT+
LT-
RT+
RT-
DB-25
AO-NC4 OUTPUT
+
EXTERNAL DEVICE
MONO INPUT
LT+
RT+
LT-
RT-
1K
1K
1K
1K
page 2 – 17
E-Series Network / Apr 2007
H A R D W A R E
AO-NC4 Panel
Analog Output Connections
CHANNEL 1 (STEREO 1 LT) OUT HI
CHANNEL 2 (STEREO 1 RT) OUT LO
CHANNEL 3 (STEREO 2 LT) OUT HI
CHANNEL 4 (STEREO 2 RT) OUT LO
CHANNEL 5 (STEREO 3 LT) OUT SH
CHANNEL 5 (STEREO 3 LT) OUT HI
CHANNEL 6 (STEREO 3 RT) OUT LO
CHANNEL 7 (STEREO 4 LT) OUT SH
CHANNEL 7 (STEREO 4 LT) OUT HI
CHANNEL 8 (STEREO 4 RT) OUT LO
AUDIO GROUND
CHANNEL 1 (STEREO 1 LT) OUT LO
CHANNEL 2 (STEREO 1 RT) OUT SH
CHANNEL 2 (STEREO 1 RT) OUT HI
CHANNEL 3 (STEREO 2 LT) OUT LO
CHANNEL 4 (STEREO 2 RT) OUT SH
CHANNEL 4 (STEREO 2 RT) OUT HI
CHANNEL 5 (STEREO 3 LT) OUT LO
CHANNEL 6 (STEREO 3 RT) OUT SH
CHANNEL 6 (STEREO 3 RT) OUT HI
CHANNEL 7 (STEREO 4 LT) OUT LO
CHANNEL 8 (STEREO 4 RT) OUT SH
CHANNEL 8 (STEREO 4 RT) OUT HI
5
4
3
2
1
17
16
15
14
8
7
6
20
19
18
10
9
23
22
21
13
12
11
25
24
CHANNEL 1 (STEREO 1 LT) OUT SH
CHANNEL 3 (STEREO 2 LT) OUT SH
DB-25
Output Ports
ANALOG
OUTPUT
page 2 – 18
E-Series Network / Apr 2007
H A R D W A R E
Logic Input/Output Card
(LIO-NC4)
Overview
The LIO-NC4 is a programmable hardware interface with a feature set
designed for broadcast studio control applications. Each Logic card provides
twelve ports that may be programmed as inputs or outputs using SW1 -SW3
dipswitches. The twelve independent, opto-isolated solid state relay inputs/
outputs may be programmed through the XPoint Logic Configuration form to
function as routable logic or triggered ports.
Routable logic allows the user to make logic signal crosspoints in the same
way audio crosspoints are made. For instance, a closure on logic input port 1
can be cross connected to logic output port 1. Later, the same closure on input
port 1 can be routed to logic output port 2, 3, or 4, etc. as required. The output
ports may be programmed to follow the input port state or to invert it. Defining
this behavior is useful when configuring the hardware for normally closed
applications. Input and output ports may be configured as logic I/O only or
may be “attached” to an audio signal. Routable logic signals may be included
as part of a Salvo.
Triggered ports allow the user to program a logic input to fire a predefined
Salvo or to make a temporary audio connection. Salvos make or break
multiple audio and/or logic crosspoints, while temporary audio connections
are useful for IFB or EAS applications. Note that triggered ports serve one,
predefined function and are not routable.
See “Configuring Logic I/O” in the Software Setup guide.
Input Ports
Each of the twelve LH1522AB solid state relay
input ports are configured as a floating photodiode,
with the + input going to the opto’s anode, and
the - input to opto’s cathode. A 475 ohm current
limiting resistor in series with each negative input
supports an external supply voltage range of +5Vdc
to +15Vdc. For external supply voltages between
+15Vdc and +24Vdc, install a current limiting resis-
tor of 220 ohms in series with each + input connec-
tion. Maximum forward photodiode current is 50mA.
When interfacing to a logic input port, we recommend the positive side be
connected to a fixed, positive dc voltage and the negative side switched to
ground to activate the logic input.
EXT
+5V - +15V
ROUTER
SIMPLE INPUT EXAMPLE
LIO IN
!
Default Setting
Card 1 is configured as
inputs. Card 2 is config-
ured as outputs.
page 2 – 19
E-Series Network / Apr 2007
H A R D W A R E
EXT DEVICE
LIO OUT
SIMPLE OUTPUT EXAMPLE
PLAY IN
GND
ROUTER
11
2
15
ON TALLY
OFF TALLY
5
12
24
25
11
+5V
25
12
24
11
5
15
2
ON TALLY
LED
OFF TALLY
LED
12
25
16
23
11
24
3
10
10
23
1
4
9
22
14
17
ON
OFF
COUGH
TB
12
25
11
24
10
23
9
22
16
4
3
17
1
23
14
+5V
EXT ON
DGND
+5V
EXT OFF
DGND
+5V
COUGH
DGND
+5V
TB
DGND
10
LIO IN
LIO OUT
LIO IN
LIO OUT
MMD #1
ROUTER
ANP-600
+
EXT V+
+
EXT V+
DIGITAL
+5V
DIGITAL
Output Ports
Each of the twelve LH1522AB solid state relay outputs
may be configured in software to function as normally open
or normally closed circuits when cross connected to an
input.
All outputs feature linear ac/dc operation, current limit-
ing, and a low on resistance, typically 10 Ohms.
Normal Operating Load Limits: 120mA, ±100V
Safety Note: The LIO-NC4 is NOT designed to safely
switch AC mains power.
page 2 – 20
E-Series Network / Apr 2007
H A R D W A R E
Software Programming
For details on programming the LIO-NC4, please refer to “Configuring Logic
I/O” in the XPoint Software Setup Guide later in this manual.
Internal Programming Options
All internal programming options are made via PCB mounted dipswitches
and jumpers.
Dipswitch / Jumper Settings
DIPSW1 -SW3 - Logic In/Out Settings
SW1 position 1 sets logic port 1 as logic input when ON or logic output when OFF.
SW1 position 2 sets logic port 2 as logic input when ON or logic output when OFF.
SW1 position 3 sets logic port 3 as logic input when ON or logic output when OFF.
SW1 position 4 sets logic port 4 as logic input when ON or logic output when OFF.
SW2 position 1 sets logic port 5 as logic input when ON or logic output when OFF.
SW2 position 2 sets logic port 6 as logic input when ON or logic output when OFF.
SW2 position 3 sets logic port 7 as logic input when ON or logic output when OFF.
SW2 position 4 sets logic port 8 as logic input when ON or logic output when OFF.
SW3 position 1 sets logic port 9 as logic input when ON or logic output when OFF.
SW3 position 2 sets logic port 10 as logic input when ON or logic output when OFF.
SW3 position 3 sets logic port 11 as logic input when ON or logic output when OFF.
SW3 position 4 sets logic port 12 as logic input when ON or logic output when OFF.
J3 - AGND to DGND - default is “CLOSED”
J3 connects Audio Ground to Digital Ground.
Hook-Ups
All user wiring from the LIO-NC4 card takes place at the female DB-25
connector on the cage rear.
Logic Connections
These include 12 input/output sources. Pinout drawing on page 2-22 shows
all wiring connections at a glance.
Pin 12 – Logic 1 In/Out +
Pin 25 – Logic 1 In/Out -
Pin 11 – Logic 2 In/Out +
Pin 24 – Logic 2 In/Out -
Pin 10 – Logic 3 In/Out +
Pin 23 – Logic 3 In/Out -
Pin 9 – Logic 4 In/Out +
Pin 22 – Logic 4 In/Out -
page 2 – 21
E-Series Network / Apr 2007
H A R D W A R E
Pin 8 – Logic 5 In/Out +
Pin 21 – Logic 5 In/Out -
Pin 7 – Logic 6 In/Out +
Pin 20 – Logic 6 In/Out -
Pin 6 – Logic 7 In/Out +
Pin 19 – Logic 7 In/Out -
Pin 5 – Logic 8 In/Out +
Pin 18 – Logic 8 In/Out -
Pin 4 – Logic 9 In/Out +
Pin 17 – Logic 9 In/Out -
Pin 3 – Logic 10 In/Out +
Pin 16 – Logic 10 In/Out -
Pin 2 – Logic 11 In/Out +
Pin 15 – Logic 11 In/Out -
Pin 1 – Logic 12 In/Out +
Pin 14 – Logic 12 In/Out -
page 2 – 22
E-Series Network / Apr 2007
H A R D W A R E
LIO-NC Panel
Logic Input / Output Connections
LOGIC 2 IN/OUT -
LOGIC 3 IN/OUT -
LOGIC 5 IN/OUT -
LOGIC 6 IN/OUT -
LOGIC 7 IN/OUT -
LOGIC 8 IN/OUT -
LOGIC 9 IN/OUT -
LOGIC 10 IN/OUT -
LOGIC 11 IN/OUT -
LOGIC 12 IN/OUT -
AUDIO GROUND
LOGIC 1 IN/OUT +
LOGIC 2 IN/OUT +
LOGIC 3 IN/OUT +
LOGIC 4 IN/OUT +
LOGIC 5 IN/OUT +
LOGIC 6 IN/OUT +
LOGIC 7 IN/OUT +
LOGIC 8 IN/OUT +
LOGIC 9 IN/OUT +
LOGIC 10 IN/OUT +
LOGIC 11 IN/OUT +
LOGIC 12 IN/OUT +
5
4
3
2
1
17
16
15
14
8
7
6
20
19
18
10
9
23
22
21
13
12
11
25
24
LOGIC 1 IN/OUT -
LOGIC 4 IN/OUT -
DB-25
Input/Output Ports
LOGIC
I / O
page 2 – 23
E-Series Network / Apr 2007
H A R D W A R E
Dual Audio Network Card
(AT-NC2)
Overview
The Dual Audio Network card provides the audio and logic link between
the central E-WHEATNET, the E-SAT, and optionally, a MICROSAT. All
Audio Transport (AT) connections are made using UTP CAT-5 wired as
crossover and terminated with RJ-45 connectors.
The 2 AT ports, LINK 1 and 2, are pre-configured in hardware and
software. LINK-1 always connects to the E-NET. LINK-2 always connects to
a MICROSAT.
Which specific E-NET port you connect LINK-1 to depends on the
configuration you have loaded. XPoint software is used to load “canned”
configurations that map the AT LINK-1 and 2 ports to specific E-NET ports.
The AT-NC2 provides a tremendous amount of flexibility and routing
power. Please note the following design aspects:
• The XPoint configuration you load determines how the system must be
wired.
• E-SAT cages always connect to the E-WHEATNET central switch.
page 2 – 24
E-Series Network / Apr 2007
H A R D W A R E
Internal Programming Options
All internal programming is done via PCB mounted switches.
Switch Settings
SW1 - Reset
Momentarily pressing the switch resets the LAN chip, while pressing and holding the switch
also resets the FPGA.
DIPSW2
Pos.1 (labeled DIPSWØ on the circuit board) - Sample Rate Select - 48kHz/44.1kHz
Selects the system’s sample rate frequency: 48kHz or 44.1kHz.
48kHz when switch is ON,
44.1kHz when switch is OFF.
Pos.2 - Not Used
Pos.3 - Disables Remote Rack
A Remote Rack is a rack connected via the LINK 2 connector.
ON - no Remote Rack,
OFF - Remote Rack connected.
Pos.4 - Normally ON
OFF - Resets cage when LINK 1 (to the E-WHEATNET) is disconnected.
Note!!
Sample Rate must match
on all E-Series Network
devices.
page 2 – 25
E-Series Network / Apr 2007
H A R D W A R E
Hook-Ups
All user wiring to and from the AT-NC2 card’s LINK1 and 2 RJ-45
connectors is made using UTP CAT5 cable wired as crossover. For typical
CAT5 cable pinouts see below.
LINK 1 and 2 RJ-45—CAT5 Audio Network Connectors
Pin 1 – TXD +
Pin 2 – TXD -
Pin 3 – RXD +
Pin 4 – N/C
Pin 5 – N/C
Pin 6 – RXD -
Pin 7 – N/C
Pin 8 – N/C
TYPICAL CROSSOVER CABLE
USED TO CONNECT THE LINK1 CONNECTOR TO THE E-NET AND THE LINK 2
CONNECTOR TO AN OPTIONAL MICROSAT.
1
2
3
4
TXD +
TXD -
RXD +
RXD -
PIN
1
2
3
4
PIN
RJ-45
Plug
RJ-45
Plug
White/Orange
5
6
7
8
N/C
N/C
5
6
7
8
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
N/C
N/C
RXD +
RXD -
TXD +
TXD -
N/C
N/C
N/C
N/C
page 2 – 26
E-Series Network / Apr 2007
H A R D W A R E
1
2
3
4
5
6
7
8
RXD +
RXD -
LINK 1 - RJ-45
TXD -
TXD +
1
2
3
4
5
6
7
8
RXD +
RXD -
LINK 2 - RJ-45
TXD -
TXD +
AT-NC Panel
Network Connections
AT
1
2
LINK
LINK
page 2 – 27
E-Series Network / Apr 2007
H A R D W A R E
Digital Signal Processor Card
(DSP-NC)
Overview
The DSP-NC card is the digital signal processing card used by the
E-SAT to mix and condition input signals. DSP cards in a given system are
physically identical. Their fuctionality is determined by input and mix
software which is loaded into each DSP card’s memory on surface
powerup. Wheatstone’s XPoint software is used to map each DSP card to
specific control surfaces and audio racks.
Each input fader has a dedicated DSP channel which is responsible for
gain, mode, phase, EQ, dynamics and metering. Likewise, each output
mix has a dedicated DSP channel responsible for summing, gain, mode,
metering and EQ/Dynamics on 5.1 Master mix outputs.
DSP cards receive instructions from control surfaces in real time over
a Mixer Transport using the “LINK” RJ-45 connector on the DSP-NC rear
panel. The mix engine DSP’s combine all of the console audio signals as
directed by a console’s faders, knobs, and switches to produce the various
Program, Aux Send, Mix Minus, and Monitor output mixes.
Internal Programming Options
There are no internal programming options on the DSP-NC card.
!
LINK is connected to the
E-Surface using a
crossover cable.
page 2 – 28
E-Series Network / Apr 2007
H A R D W A R E
Hook-Ups
All user wiring to and from the DSP-NC card’s LINK RJ-45 connector is
made using UTP CAT5 cable wired as crossover. For typical CAT5 cable
pinouts see below.
LINK—CAT5 Audio Network Connectors
Pin 1 – TXD +
Pin 2 – TXD -
Pin 3 – RXD +
Pin 4 – N/C
Pin 5 – N/C
Pin 6 – RXD -
Pin 7 – N/C
Pin 8 – N/C
TYPICAL CROSSOVER CABLE
USED TO CONNECT THE LINK CONNECTOR TO AN OPTIONAL CONTROL SURFACE.
1
2
3
4
TXD +
TXD -
RXD +
RXD -
PIN
1
2
3
4
PIN
RJ-45
Plug
RJ-45
Plug
White/Orange
5
6
7
8
N/C
N/C
5
6
7
8
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
N/C
N/C
RXD +
RXD -
TXD +
TXD -
N/C
N/C
N/C
N/C
page 2 – 29
E-Series Network / Apr 2007
H A R D W A R E
1
2
3
4
5
6
7
8
RXD +
RXD -
LINK - RJ-45
TXD -
TXD +
DSP-NC Panel
Network Connections
DSP
LINK
page 3 – 1
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
XPoint Software Setup Guide
Chapter Contents
E-WHEATNET Ethernet/IP Address Quick Start.........................3-3
Ethernet Cabling ....................................................................................................... 3-3
Default IP Address .................................................................................................... 3-3
Changing your PC’s IP Address ............................................................................... 3-3
Changing the E-WHEATNET’s IP Address .............................................................. 3-4
Configuring IP Address in X-Point Software ............................................................ 3-4
Saving the System Configuration ............................................................................. 3-4
Getting Started ..............................................................................3-5
Basic System Requirements ........................................................3-5
GUI Log-In ......................................................................................3-6
Password .................................................................................................................. 3-6
Connecting E-WHEATNET and XPoint........................................3-6
IP Addressing ................................................................................3-7
System Configuration Menus ......................................................3-7
Tier Configuration ..................................................................................................... 3-8
E-WHEATNET Rack Configuration .......................................................................... 3-9
Surface Setup ........................................................................................................... 3-9
E-SAT Rack Configuration ...................................................................................... 3-10
Visibillity Settings ..................................................................................................... 3-11
VDip Settings ........................................................................................................... 3-12
Line Gain.................................................................................................................. 3-13
Microphone Gain ..................................................................................................... 3-13
Mix Minus Polarity.................................................................................................... 3-13
Password Modes ..................................................................................................... 3-13
Programmable Buttons ............................................................................................ 3-14
Connection Between the Config. GUI and E-WHEATNET ........3-15
Signal Definition ...........................................................................3-18
Configuring Logic I/O ..................................................................3-19
Overview .................................................................................................................. 3-19
Routable Logic ......................................................................................................... 3-19
Triggered Port Logic ................................................................................................ 3-19
Routable Logic Signal Definitions ............................................................................ 3-20
Defining Routable Logic Functions.......................................................................... 3-21
Viewing Defined Logic Signals ................................................................................ 3-21
Configured Triggered Port Logic ............................................................................. 3-22
Signal Locking..............................................................................3-23
Salvo Definition ............................................................................3-24
page 3 – 2
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Main Menu Summary ...................................................................3-25
File Menu ................................................................................................................. 3-25
User Menu ............................................................................................................... 3-25
Configure Menu ....................................................................................................... 3-25
View Menu ............................................................................................................... 3-26
Help Menu................................................................................................................ 3-26
Diagnostics Menu .................................................................................................... 3-26
Diagnostics Menu Examples ................................................................................... 3-27
page 3 – 3
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Caution!
Configuring the Wheatstone E-Series Network hardware is a
relatively simple process. Improper configuration changes may
cause improper operation or disable previously operating func-
tions. If done properly, configuration changes can be made
while “on the air” without disruption; however it is always best
to restrict configuration changes to time periods when an error
could be tolerated. When in doubt, please contact Wheatstone
Technical Service to avoid any error in configuration changes.
E-WHEATNET Ethernet / IP
Address Quick Start
Ethernet Cabling
• Use a CAT 5 crossover Ethernet cable to connect a PC directly to the
E-WHEATNET, OR
• Use a standard CAT5 Ethernet cable to connect the E-WHEATNET to your network
hub.
Default IP Address
The E-WHEATNET IP Address is set to 192.168.1.160 at the factory. In order to
connect using the XPoint software, the PC must have a matching network prefix (i.e
192.168.1.xxx). If your PC's current IP address does not match you must choose one of the
following options:
• change the IP address of the PC running the XPoint software.
or
• change the IP address of the E-WHEATNET.
Changing your PC's IP Address
To set your PC's IP address you must access the TCP/IP Properties form for the network
adapter. The exact procedure depends on the specific version of Windows™ you are
running. Generally speaking:
• Navigate to the Settings • Control Panel • Network configuration form.
• Highlight the TCP/IP line item for your PC's ethernet adapter.
• Click the "Properties" button (the TCP/IP Properties form should open).
• Click "Specify an IP Address" (DHCP not supported).
• Enter an IP address in the range of 192.168.1.2 to
192.168.1.254 (excluding .160).
• Enter a Subnet Mask value of 255.255.255.0
When in doubt, check with your Windows ™ documentation or network administrator
for specific details on altering the network adapter's TCP/IP properties.
!
page 3 – 4
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Changing the E-WHEATNET's IP Address
Changing the IP address of devices in the system requires the editing of a text
file located on the E-WHEATNET’s system CPU. You will need a third party
FTP application to be able to FTP to the E-WHEATNET. We recommend the
freeware FTP client FTP Surfer by Whisper Technology. Google™ to “FTP
Surfer “ to download the client. Windows™ Internet Explorer™ allows FTP,
but in our experience it is not the best choice for this file maintenance
application.
To change the IP address scheme, carefully follow the instructions in the
Configuring System IP Addresses Appendix 1 at the back of this manual.
Configuring IP Address in XPoint Software
Next, start the XPoint application, log on as administrator (default
password=Admin), and navigate to the Configure•System menu item. The
following form will appear.
Important:
• If you changed the E-WHEATNET’s IP Address, enter the parameters you
entered in the xp_net.txt network text file.
If you are connected to the router, you should see a "Connecting to..."
message in the status bar at the bottom of the screen.
Saving the System Configuration
Once you connect for the first time be sure to save the configuration. Choose
the File• Save main menu option from the toolbar. When you make subsequent
changes (e.g. rename Sources or Destinations, add controllers, etc.) be sure to
save them.
Important Note!
This form tells the XPoint software
where the CPU is located on the
network. To modify the actual net-
work settings of the CPU card lo-
cated in the system’s Master Rack
- see Configuring System IP Ad-
dresses Appendix 1.
Important Note!
Before closing this form and sav-
ing your configuration make sure
the Tier ID spin box shows the
main system CPU Tier number,
usually 1.
page 3 – 5
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
XPoint Software Setup Guide
Getting Started
All Wheatstone Network System hardware is pre-configured at the
factory. This approach greatly speeds the installation process getting you
“online” faster. You may not need to make any software configuration
changes.
The XPoint software used to customize and configure the Wheatstone
Network System is supplied with your system on CD-ROM. It is a Win-
dows™ Graphical User Interface (GUI) program, intended to be straightfor-
ward in use. To install XPoint software be sure that the PC you wish to use is
Windows™ compliant, has a CD-ROM drive, and has an available ethernet
connection.
Also included on the CD-ROM is the DEFAULT configuration for your
specific system. It is very important that you copy this default folder to your
PC. This will ensure that when XPoint is started, the correct configuration
files for your system are loaded. The default configuration path for the
configuration is: C:\Program Files\Wheatstone\Xpoint\cfg\default.
Install the software on the PC by loading the X-Point CD into the drive tray
and then running the install wizard on the CD by double-clicking on
“Setup.exe”.
The following sections will guide the user through all phases of the
software configuration.
Basic System Requirements
Platform - PC, Operating system - Windows XP - Service Pack 2, Win
2000
Memory - 256MB, Hard Disk - 20 GB
Monitor -1024 x768
Network - 100BaseT NIC, optional 2nd NIC for Wheatstone Support
access
AE Network / Nov 2006
page 3 – 6
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
GUI Log-In
Once the XPoint software has been installed and started,
a “Log In” dialog box will be displayed on the screen.
Administrator - allows logged in user complete access to
hardware configuration, signal naming, I/O crosspoint switch-
ing, and destination locking.
While in Admin mode you can change the password that
is used to enter Admin mode. Select the User/Change Pass-
word... menu option to bring up the “Change Password”
dialog box. Enter a password between 4 and 10 characters
long in the “New Password:” text box, then re-enter the
password in the “Verify Password:” text box. Click “OK” to
change the password or “Cancel” to cancel the operation.
Custom users access may be created at the
factory—contact Wheatstone sales.
Password
The default password is “Admin” for Adminis-
trator.
Once logged in as Administrator the GUI at-
tempts to connect to the switch and uploads the
current configuration and crosspoint status onto the
PC. This may take 30 seconds or more. Check the
lower left hand corner of the screen for connection
status.
Connecting E-WHEATNET and XPoint
E-WHEATNET and the PC running the XPoint GUI must be con-
nected together in a stand alone LAN through an Ethernet switch. All other
devices in the E-WHEATNET system (e.g. control surfaces, XY control-
lers, automation interfaces, etc.) will also be connected through this LAN.
E-WHEATNET should be installed, powered-up, and verified to be
operating normally; you should see source and destination signal names
in any XY controllers, and the ERROR LED should not be lit. Connect a
straight CAT5 cable from the LAN switch to E-WHEATNET’s RJ-45
ETHERNET jack on the rear. Likewise, the GUI should be installed on the
desired PC and also connected to the LAN.
page 3 – 7
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
IP Addressing
All devices connected on the E-WHEATNET system LAN must have static
IP addresses and share the same network prefix /subnet mask. The default
network prefix is 192.168.1.xxx, and the default subnet mask is 255.255.255.0.
It is possible to change the IP addresses of your system by editing a simple
text file, XP_NET.txt, located on the E-WHEATNET CPU. An FTP client
application is used to gain access to the files stored on the CPU. Please see
Appendix 1 or contact Wheatstone Technical Support for details.
System Configuration Menus
From the user point of view, configuration of the Wheatstone E-Series
Network system is relatively simple, since the Configuration GUI does much
of the actual underlying configuration assignment work automatically. This
section will outline a general procedure for configuring an E-Series Network
system.
page 3 – 8
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Tier Configuration
Note that your system was pre-configured and this step is not necessary
unless you have changed the IP address of the E-WHEATNET.
Before you can connect to the system the Configuration GUI must be
setup with some information regarding the E-WHEATNET’s network
parameters. This is done by selecting the Configure / AdvXP Setup menu
option; the following Tier Configuration form appears.
The IP Address value for Tier ID1 must match the current settings of
the E-WHEATNET CPU in order to connect. Make sure Tier ID “1” is
showing before clicking the Apply button.
After clicking the Apply button the GUI software will be in the
“CONNECTING” state, as discussed in the next section. This completes
the Tier Configuration process.
Important Note!
This form tells the XPoint soft-
ware where the Host CPU is
located on the network. To
modify the actual network set-
tings of the Host CPU card lo-
cated in the system’s Master
Rack, see Configuring System
IP Addresses Appendix 1.
Note: When done, the Tier ID
spin box must show the Tier
number of the Tier that
houses the main system CPU
(usually Tier 1) or XPoint will
not be able to connect to the
system on startup.
page 3 – 9
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
E-WHEATNET Rack Configuration
Note that your E-WHEATNET was pre-configured and this step is not
necessary unless you are reconfiguring the system.
Start up the Configuration GUI and log in to the software as Administrator.
Select the Configure / AdvXP / Rack
Defs... menu option. The following form
appears.
There are the 2 banks (1-8 and 9-16)
of RJ-45 connectors each with eight
connectors
available
for
the
E-WHEATNET.
Surface Setup
Note that your system was pre-configured and
this step is not necessary unless you have changed
the IP address of a surface.
Control Surface configuration is done by select-
ing the Configure / Surface Setup menu option; the
Surface Setup form, shown on the right, appears.
For each Surface ID is used in the system you
can edit the Control Surface Name (up to 8 charac-
ters) and the IP Address.
!
Ports 17 through 48 are dis-
abled in E-WHEATNET
systems.
page 3 – 10
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
E-SAT Rack Configuration
Note that your E-SAT racks are configured at the factory, and you do not
have access to change configuration .
Select the Configure / AdvXP / Rack Defs... menu option, the following
form appears, and you will be able to view racks configuration.
Right-click on the appropriate slot in the E-SAT rack to view Input
Properties, Output Properties, Logic I/O Properties, or Card Properties
for DSP, depending on the slot you select.
page 3 – 11
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Visibility Settings
To view the control surface’s visibil-
ity settings select Configure / E6 / Visibil-
ity Settings menu option, which will
display the form on the right.
By scrolling up and down the “Con-
trol Surface Id” box, choose the appropri-
ate control surface by its unique number.
Then view or modify the settings for X
Controller (faders and switched meter)
and Studio (monitors) by clicking on the
appropriate tab. To modify settings (by
default all signals are visible) click the
Select Subset radio button.
Next highlight the desired source
signal(s) in the left column, then click on
the single right arrow box (>) found be-
tween the columns. In order to make all
signals visible click the double right ar-
row (>>) box found between the col-
umns. The left arrow buttons are to re-
move signal(s) from the visible list found
in the right column. Clicking the Apply
button will save the visibility options.
• Sort by... - User may choose to sort the
displayed signals according to Signal
ID, Signal Name, or Signal Location.
• Subsets - User may create subsets of
signals and apply the subset to indi-
vidual inputs (EQs), studios, etc.
• Apply Settings to All EQ’s - This button takes the selected set of Assigned
Source Signal and applies it to all of the selected control surface’s input
X Controllers.
• Refresh - It is possible for the visibility settings stored with XPoint to be out
of sync with the settings stored in the surface - this button causes the surface
settings to override the current settings as displayed in XPoint (but not the
settings stored with XPoint, unless you use the button and then save your
config).
page 3 – 12
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
VDip Settings
To view or modify the Virtual Dip Switch Settings select the Configure / VDip
Settings menu option, which will display the forms shown below. The content of the
forms will vary depending on the surface type. The Defaults tab (shown on the left
below) shows the default values for all signals unless specifically overridden. To
override settings for a signal press the “Per Signal” tab, dial up the desired Input Signal
ID, check the “Override Defaults” box, make your selections, and click the “OK”
button to save your changes.
• PFL/Cue Dropout - When a channel’s CUE button is pressed it will assign the
channel’s signal to the CUE bus. When “PFL/Cue Dropout” is checked it causes the
channel’s CUE function to be de-activated whenever the channel ON switch is
pressed.
• EFS - Will turn the channel OFF when the fader is moved all the way down and turn
the channel ON when the fader moves from the fully down position.
• Fader Cue - Will assign the signal to the Cue bus when the fader is moved all the way
down.
• UTL Pre Fader - When checked will cause the signal assigned to the UTL output to
be tapped before the fader. On the E-6 surface there is no UTL output - instead the
function applies to the PGM D output.
• UTL Pre On - When checked will cause the signal assigned to the UTL output to be
tapped before the channel ON/OFF switches. On the E-6 surface there is no UTL
output - instead the function applies to the PGM D output.
• Timer Restart - The digital timer can be programmed to automatically reset to zero
and begin counting up when the channel’s ON button is pressed. To enable this
function the “AUTO” button in the timer section has to be activated.
page 3 – 13
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
• Machine Start Pulsed - This check box has no effect.
• Remote Ready - Will control the channel’s OFF switch LED with a signal from an
external source machine instead of it being controlled directly by the surface.
• Studio Mutes - Input channels can be programmed to mute the studio or cue speakers
when the channel is ON. There are five studio mutes options. Checked boxes show
which speakers are muted.
• Studio Tallies - Turning the channel ON can activate a remote tally indicator. There are
four tally control lines.
• Bus Minus Pre Fader - sets the input signal sent to the Bus Minus system to be pre-fader.
If this box is unchecked it is post fader.
• Bus Minus Follow Channel On - Sets the input signal sent to the Bus Minus system to
follow the channel ON switch.
Line Gain
To view or modify the line input channel gain select
the Configure / Line Gain menu option, which will
display the form shown at the right.
Each control surface and input signal is identified via
the “Control Surface Id” and “Input Signal Id” spin edit
boxes. Define the line gain level and click the “OK”
button.
Click the Unity Gain button to set gain to 0.0dB.
Microphone Gain
To view or modify the mic input channel gain select
the Configure / Microphone Gain menu option, which
will display the form shown at the right.
Use this control in systems that have mic input cards
but do not have control surfaces with mic gain controls.
Mix Minus Polarity
To modify the mix-minus polarity select the Config-
ure / Mix Minus Polarity menu option, which will
display the form shown at the right.
• Negative - Preferred in Radio applications; requires
users to assign each fader to a MXM bus.
• Positive - Preferred in TV applications; users simply
press a single MXM switch to subtract the fader from
the MXM bus.
Password Modes
This menu item does not apply to E-Series surfaces. Password control of the E-Series
surface is done at the surface, see the surface manual for details.
page 3 – 14
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Programmable Buttons
The control surface’s programmable buttons can be used in different ways.
If you want a button to fire a
Salvo or make a temporary
crosspoint, select the Configure /
Spare Button LIOS menu, which will
display the form shown at the right.
To program a button to fire a Salvo,
check the box immediately to the
right of the Spare Button number,
then select a Salvo from the pulldown
list under Fire Salvo. The Salvo will
fire whenever the programmed but-
ton is pressed.
To cause the button to make a
temporary crosspoint, check the box
to the right of the word “or” on the
same line as the desired button num-
ber, then select the desired Source
and Destination Signals for the tem-
porary crosspoint. For example, let’s
say you program button 3 to tempo-
rarily connect a source named “OUT
1” to a destination named “IN 1”. As
long as you are holding button 3
down, OUT 1 will feed IN 1. If a
different signal was feeding IN 1 to
start, that connection will disappear while the button is pressed and reappear when
the button is released.
You can also control a physical logic output with a programmable button. When
the system is originally created, two signals will be auto-generated to enable
programmable button use: ExxSPAR1 is associated with buttons 1-6, and ExxSPAR2
is associated with buttons 7-12. If you look at the signal definitions of these signals,
you will find that function names are assigned to them. You can use default names,
or create your own. The key is to create a physical Logic Only destination (see page
3-20 for details), such as LOut1, and use the same function name for that destination
as you are using for programmable button that will control it. Assuming for the
moment you are working with button 1, the last step is to make a crosspoint on the
XPoint grid to connect ExxSPAR1 (remember, it deals with buttons 1-6) and your
Logic Only destination (in this case, LOut1). The combination of the crosspoint and
the matching function names causes the specified logic output port to respond to
button 1.
In a similar manner the LEDs that light up the programmable buttons can be
controlled by physical logic inputs. Once again you create a physical Logic Only
destination, map a source signal to the programmable button signal by function
name, and make the crosspoint connection in XPoint.
Note: The “xx” part of the signal name is usually the surface number in a multi surface system. These signals are located
in the horizontal Sources set of signals and are typically in the signal space above signal ID 1000 of the XPoint grid.
page 3 – 15
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Yellow
Status
Indicator
Status
Message
Connection Between the Configuration GUI and
E-WHEATNET
While in OFFLINE mode, the GUI does not communicate to the Host CPU in the
master rack. This is useful to work through initial hardware and signal definitions,
which may be downloaded later. The program starts in ONLINE mode but can be
switched to OFFLINE mode by selecting the View / Mode / Offline menu option.
In ONLINE mode a TCP connection to the Host CPU will be attempted, as
indicated by the status message and yellow status indicator shown below.
When the GUI successfully communicates with the E-WHEATNET CPU soft-
ware it will start receiving the configuration that the E-WHEATNET CPU has stored
in its nonvolatile memory. While downloading this configuration information the
yellow status indicator turns green and the status message changes from CONNECT-
ING to something similar to the following (varies with tier name and IP/address):
“Downloading Config From 192.168.1.160 [Tier 1]”.
page 3 – 16
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Once the configuration
has been downloaded the
GUI enters the ONLINE state
as shown to the left.
To disconnect from the
E-WHEATNET CPU and go
to OFFLINE mode, select
the View / Mode / Offline
menu option. The status in-
dicator on the screen will then
change as shown to the left.
Red
Status
Indicator
Status
Message
Green
Status
Indicator
Status
Message
page 3 – 17
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
To connect to the E-WHEATNET CPU while in OFFLINE mode, select the
View / Mode / Online menu option. The status indicator on the screen will then
change to CONNECTING as discussed above.
If the user makes any configuration or crosspoint changes in OFFLINE
mode and then goes to ONLINE mode, this message box pops-up:
Choose YES to save OFFLINE changes.
There are three tabs, View AdvXP Status / View Surface Status / View Log,
on the bottom of the Configuration GUI form to view rack configuration, status
of all active installed hardware, and card firmware revisions. A window like the
following will appear when you click on the View AdvXP Status tab.
page 3 – 18
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Signal Definition
Up to 512 separate source and destination signals may be defined via the
Configuration GUI (up to 2048 in multi-tier installations). To add or edit a
signal from the GUI’s main grid, right click on one of the Source or
Destination signals and select “Modify Signal Definition”. To define a signal
while in the Configure / AdvXP / Rack Defs form, click on an input card; press
the Signal Definitions button.
Each signal is automatically assigned a unique Signal ID number. For
each Signal ID number the following parameters can be configured:
• Signal Name: Enter the 8 Character name to be displayed on XY controllers
and the Xpoint GUI.
• Location: Enter an optional 8 Character description of the signal’s location.
• Audio Signal Type: Choose Source or Destination.
• Format: Choose Logic I/O Only, Mono, Stereo, or 5.1 Surround.
• Audio Signal Location Tab: Defines the signal’s physical location - Tier,
Rack, Slot, Circuits.
• Logic I/O Tab: Maps up to twelve routable logic port signals to the current
audio signal. Also used to define Logic I/O signals only. See the “Config-
uring Logic I/O ” section for details.
Most of these parameters are self explanatory. When defining the audio
signal location, remember that XPoint circuits are equivalent to a single audio
channel. Every audio card has four stereo channels (4x2 channels = 8
circuits).
Note that signals may be virtually mapped to locations that do not
currently have appropriate hardware. These “virtual” signals exist in soft-
ware, but may not be used until appropriate hardware is added to the defined
locations. This feature allows a set of default signal names to be provided
independent of hardware configuration.
page 3 – 19
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Configuring Logic I/O
Overview
The LIO-NCA adds 12 programmable logic functions, configured
individually as inputs or outputs, per card. The addition of logic I/O adds
a powerful level of complexity to your Wheatstone router and care must
be exercised during configuration to ensure the proper results. It is
important to understand that there are two primary ways to configure the
physical logic ports in software - routable logic or triggered ports. Which
type you choose depends on the particular application.
Routable Logic
Routable logic allows the user to make logic signal crosspoints in the
same way audio crosspoints are made. Routable logic may be configured
as independent “LIO Only” signals (e.g. switch inputs and solid state relay
outputs); or up to twelve logic input or output signals may be mapped, or
“piggybacked”, onto audio signals.
Independent “LIO Only” logic signals may be cross connected just like
audio signals. An external switch or relay closure wired to activate a logic
input may be routed to control device A, B, C, etc., as required. The
duration of the solid state relay output follows the duration of the input
signal, thus allowing for latched or momentary applications. LIO Only
Sources are typically cross connected to LIO Only Destinations, but
mapped logic signals may be cross connected to independent logic signals
as long as the assigned logic functions match.
Mapped logic signals enable the user to automatically route up to
twelve logic signals along with an audio source. When an audio source is
routed to a destination, all logic mapped to the source device is automati-
cally routed to the destination device. The mapped logic I/O configuration
greatly simplifies the management of control signals in a variety of
scenarios including multi-recorder control, backup automation switch-
over, and studio sharing applications.
Triggered Port Logic
Triggered port logic is a special class of logic I/O that uses a GPI or
simple switch closure to fire a predefined Salvo or to make a temporary
audio crosspoint. When a logic input port has been configured as a
triggered port, the corresponding output port is dedicated as a tally-back
function. Tally-back is provided as a means of confirming that the salvo
has fired or the temporary audio crosspoint has been made. Triggered port
logic is configured using the LIO Card Definitions form. Please see
Configuring Triggered Port Logic later in this section.
page 3 – 20
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Routable Logic Signal Definitions
There are two types of routable logic signals - Logic I/O Only or Mapped Logic I/O.
All routable logic signals must first be defined using the Signal Definitions form. To add
a new routable logic signal right click on a source or destination signal, then click Modify
Signal Definition to open the Signal Definitions form. The following form should appear.
Click on ether Logic I/O tab to view the logic parameters.
As with audio Sources and Destinations, each signal is automatically assigned a unique
Signal ID number. For each Signal ID number, the following parameters can be configured:
• Signal Name: Enter 8 Character name displayed on controllers and Xpoint GUI
• Location: Enter optional 8 Character description of signal’s location
• Audio Signal Type: Source or Destination will already be selected
• Format: Choose Logic I/O Only, Mono, Stereo or 5.1 Surround
• Audio Signal Location Tab: Defines the audio signal’s physical location - Tier, Rack,
Slot, Circuits (not used for Logic I/O Only signals)
• Logic I/O Tab: Maps up to twelve routable logic port signals to the current signal.
• Enabled -LIO#1 through #12, check to activate up to twelve LIO’s
• Tier, Rack & Card - identify physical location of logic card
• Port# - choose one of 12 available physical ports
• Direction - In or Out - selects input or output port type
• Invert - flips the normalled port state (i.e. N.O. to N.C.)
Example - To add a single logic input function to a Source signal:
• Click on the LIO#1 Enabled checkbox.
• Select the logic card’s physical location in a rack.
• Choose one of the twelve available logic ports on the card.
• Pick a direction; control outputs from a device connect to the logic card input ports, control
inputs to a device connect to logic card output ports. Important: the direction must
match the dipswitch setting for that logic port on the LIO-NCA card.
• Invert - leave unchecked unless you need to change a port’s normally open behavior.
• Function - Select a function name, e.g “Start”. Note that both the Source and Destination
signals must have the same function names enabled in order to complete the circuit.
Please see Defining Routable Logic Functions below for more information.
page 3 – 21
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Defining Routable Logic Functions
Mapped logic and Logic I/O Only signals rely on common function names as
a way of “knowing” which physical logic inputs need to control which physical
logic outputs. When you map logic signals to an audio signal or create “logic only”
signals using the Signal Definitions form, you must provide a unique logic
Function for each LIO# enabled. When you make a crosspoint between a source
and destination, the software checks the list of logic functions associated with the
source against the list of logic functions associated with the destination and cross
connects any logic signals with the same “Logic I/O Type” name.
Logic functions are created from the Logic I/O Types form. Up to 100 logic
functions may be defined. First, open the Signal Definitions form by right clicking
on a source or destination signal in the GUI’s main grid, then click on one of the
two Logic I/O tabs, then click on the “Define ” button in the lower right corner to
open the Logic I/O Types form shown at the right.
• ID - static value from 1 to 100 , cannot be changed. Use
the up /down arrows to scroll to the desired function
number.
• Name - Be sure to assign each function a unique name to
avoid potential confusion when mapping logic functions.
Names may be up to 8 characters long.
• Precedence - always set to “Controller” for logic card
applications. “Device” setting is reserved for future use.
• Disconnected Output State - Choose the desired state to
leave the output in when this function is disconnected.
Choices are OFF (open), ON (closed) or Current Value
(last known state). OFF is must often the correct
choice.
Viewing Defined Logic Signals
The “Logic IO Properties” form provides a way to
quickly determine which logic signals have been
assigned to a particular logic card and if any spare
logic ports are available.
Select the Configure / Rack Defs... menu option
to view a given rack. You may now query any logic
card by right clicking on its location. A form similar
to the one on the right will be displayed. The “Asso-
ciated With Xpoint” tab displays all mapped and
routable logic signals on the card. The “Directly
Triggered” tab displays all of the Triggered Port
assignments on the card.
page 3 – 22
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Configuring Triggered Port Logic
Triggered logic ports enable the firing of salvos or temporary audio
connections from a GPI or simple switch closure. When an input is configured
to be a triggered port, its corresponding output is automatically assigned to be
a Tally-back. Configuration of Triggered ports is done through the LIO Card
Definitions form.
To open the LIO Card Definitions form, log on as Administrator and
navigate to the Main Menu item Configure / Rack Defs. Select the Tier and
Rack location and left click on the logic card to be configured. The following
Card Definitions form should be
visible.
The “Location” section at the
top of the form indicates the physi-
cal location of the LIO-2001 logic
card. The “Triggered Port Assign-
ments” section allows the 12 logic
input/output ports to be configured.
Logic ports on this card which have
already been configured as routable
logic will appear to be grayed out.
The following form description
includes parameters that may be con-
figured:
• Input Port - indicates which physi-
cal port is being configured.
• Salvo check boxes - assigns input
port to fire a salvo.
• Salvo - use drop down list arrow to
select a Salvo to be fired.
• Temporary Connection check
boxes - assigns input port to tem-
porarily connect a source to a
destination (also temporarily disconnects the current source).
• In Signal - use the up/down scroll arrows to select the temporary source signal.
• Out Signal - use the up/down scroll arrows to select the affected destination.
• Port Sense (Edge) - choose “+” to trigger on a low-to-hi input transition,
choose “-” to trigger on a hi-to-low input transition.
• Output Port - indicates which physical port is used for Tally-back.
• Invert Feedback State checkbox - flips the normally open behavior of the
Tally-back output.
Once the Triggered Port Assignments have been defined, press the “Apply”
button to complete the configuration. The “ Logic I/O Only Signals ” button is
provided for convenience and opens the “Signal Definitions” form. This may
be useful to quickly un-assign mapped logic ports, making them available for
Triggered Port assignment.
page 3 – 23
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Signal Locking
To lock a signal, right click on the desired output channel on the crosspoint
grid and select “Lock Connection”.
That crosspoint output signal becomes locked as indicated by the red line
through the signal on the GUI display and shown on form below.
Note that you must be in ONLINE mode to lock a connection.
page 3 – 24
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Salvo Definition
Macro control of the E-WHEATNET is accomplished by creating and
firing Salvos. A Salvo is simply a group of cross connects, disconnects and “do
nothings” that occur when the selected Salvo is fired. Each Salvo has a unique
name and can be programmed to be visible to any XY controller.
To define a Salvo, use the Configuration GUI and enter Salvo Edit Mode by
selecting the View / Mode / Edit Salvos menu. The operator may then choose
to modify the grid connections in an existing Salvo, or use the Salvo toolbar
icons to rename an existing Salvo or to create a new one. By making and
breaking connections on the crosspoint grid, the operator builds up a Salvo
definition. The order in which Salvo actions are created determines the
“playback” order. It is important to disconnect a source routed to a destination
signal that has logic attached before routing the source to a new destination to
avoid illegal logic state conditions.
When completed, the operator leaves Salvo Edit Mode, at which point the
newly defined Salvos are available for use. If the application is connected to a
switch (ONLINE mode) the new Salvo definitions are automatically sent to the
switch. It is a good idea to save the newly created Salvos on the PC by choosing
File / Save... from the main menu.
Note that clicking on the Delete Salvo icon in the Salvo Toolbar will
initially delete all the connections defined in a Salvo; a subsequent click on this
button will delete the Salvo from the Salvo list. This is a useful way to clear out
an existing Salvo and then redefine the connections within that Salvo. To cancel
changes made to a Salvo select View / Mode / Cancel Salvo Edits from the main
menu.
An example of Salvo Edit mode is shown below.
Caution!
A yellow line through a con-
nection means the connec-
tion will be switched OFF
when the Salvo is fired.
<-Salvo Tool Bar
• Rename Salvo
• New Salvo
• Clear/Delete Salvo
Note: If the Salvo Tool
Bar is not visible, select
View / Tools / Salvo from
the main menu.
page 3 – 25
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Main Menu Summary
The following is a summary of all the available menu choices when logged into
XPoint as the Administrator.
File Menu
Open : Opens the Load Configuration form to load previously saved configuration
elements for off-line viewing/editing or download to Host CPU.
Save : Opens the Save Configuration form to save any or all changes.
Send Cfg To Switch : Initiates download of currently loaded configuration to the
Host CPU module. Use this to update the system hardware with config changes.
Send Cfg To E6 Surface : Initiates download of currently loaded configuration to
the control surface. Use this to update the system hardware with config changes. You
can select individual surfaces or update all surfaces at once.
Request Cfg From Switch : Request the current configuration from the router.
Request Cfg From E6 Surface : Request the current configuration from all control
surfaces of this type, or from individual surfaces.
Export Signals : Export signal names to a comma separated format suitable for
speadsheet input.
Exit : Exits the XPoint program.
User Menu
LogIn/LogOut : Opens the XPoint Log-in form if currently logged out, else logs
out if logged in.
Change Password : Allows the Administrator to change the Admin access level
Log-in password.
Configure Menu
AdvXP Setup : Configure tier names and IP Addresses.
Surface Setup : Configure surface, name, and IP Address.
AdvXP
Rack Defs : Define installed hardware parameters on a rack by rack basis.
Allows user to “see”, define and configure all installed cage hardware.
XY Controller Configuration : Used to define and configure hardware based
serial (not Ethernet) XY controllers present in the system. Access XYC Signal
Visibility editing here. Ethernet Controllers use a separate application for visibility.
E6
Visibility Settings : Define input and output signal visibility.
VDip Settings : Define muting, tally, and other surface behavior.
Line Gain : Make gain adjustments on line inputs.
page 3 – 26
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Microphone Gain : Make gain adjustments and enable/disable phantom power on
mic inputs.
Mix Minus Polarity : Set additive or subtractive mode.
Passwords : Not used with E-Series surfaces.
Spare Buttons LIOS : Used to assign programmable buttons to fire Salvos and to
make a temprorary crosspoint.
View Menu
Mode-OffLine : Select OFF-LINE to edit configuration. Be sure to Save configu-
ration prior to returning ON-LINE. This menu option is only available if you are
currently ON LINE.
Mode-Online : Initiates network connection to Host CPU, uploads Host configura-
tion once connected. View real time status of all crosspoints. This menu option is only
available if you are currently OFF LINE.
Mode-Edit Salvo : Create, define and edit Salvos in this mode. This menu option is
only available if you are not in Salvo Edit mode.
Mode-Leave Salvo Edit Mode : Exit Salvo Edit mode. This menu option is only
available if you are in Salvo Edit mode.
Mode-Cancel Salvo Edits : Cancels any edits made in Salvo Edit mode and exits
Salvo Edit mode. This menu option is only available if you are in Salvo Edit mode.
Tools-Inputs : Toggles visibility of the Input toolbar.
Tools-Salvo : Toggles visibility of the Salvo toolbar.
Tools-Outputs : Toggles visibility of the Output toolbar.
Tools-Signal Visibility : Toggles visibility of the Signal Visibility toolbar.
Zoom 1x-2x-3x : Zoom in and out of XPoint grid.
Help Menu
How To... : Opens help hints text file.
About : Shows XPoint software revision.
Diagnostics Menu
View TCP Connection Status : Opens a window displaying TCP/IP connection
status for the router and all surfaces.
View System Health Status: Lists all E-WHEATNET ports, shows partner E-SAT,
and CAT5 link status. Reveals intermittent or broken cabling and devices.
View UDP Log : Opens error logging permission. May be enabled/disabled.
Reset Switch : Initiates a Host CPU reboot. Use this function with caution!
System Integrity Check : Used to verify the AdvXP and surface configurations, and
signal mappings.
page 3 – 27
E-Series Network / Apr 2007
X P O I N T S O F T W A R E S E T U P G U I D E
Diagnostics Menu Examples
View TCP Connection Status Form:
View System Integrity Form:
page 4 – 1
E-Series Network / Apr 2007
S C H E M A T I C D R A W I N G S
I/O Schematic Drawings
Chapter Contents
4 Analog Inputs Network I/O Center (AINC-4)
Schematic ................................................................................................................. 4-2
Load Sheet................................................................................................................ 4-4
4 Analog Outputs Network I/O Center (AONC-4)
Schematic ................................................................................................................. 4-5
Load Sheet................................................................................................................ 4-7
4 Digital Inputs Network I/O Center (DINC-4)
Schematic ................................................................................................................. 4-8
Load Sheet............................................................................................................... 4-10
4 Digital Outputs Network I/O Center (DONC-4)
Schematic ................................................................................................................ 4-11
Load Sheet............................................................................................................... 4-12
Logic Interface Network I/O Center (LIONC-12)
Schematic ................................................................................................................ 4-13
Load Sheet............................................................................................................... 4-15
Dual Audio Transport Network I/O Center (ATNC-2)
Schematic ................................................................................................................ 4-16
Load Sheet............................................................................................................... 4-18
Digital Signal Processor Card (DSP-NC)
Load Sheet............................................................................................................... 4-19
SAT-E Mother Board (MBNC-1)
Schematic ................................................................................................................ 4-20
Load Sheet............................................................................................................... 4-21
S-16 Wheatnet-E Super Hub Main Card (IB-1)
Load Sheet............................................................................................................... 4-22
S-16 Wheatnet-E Super Hub LED Card (IBEL-1)
Load Sheet............................................................................................................... 4-23
S-8 Wheatnet-E Super Hub Main Card (IBA-1)
Load Sheet............................................................................................................... 4-24
Micro Satellite Main Card (MCS-8 & MCS-8E)
Load Sheet............................................................................................................... 4-25
1 OF 2
AINC-4
AINC-4 PCB
--
WWP/SA
E-Series Network / Apr 2007
page 4 - 2
SA
SA
- SA UR US - Sergey Averin -
APPROVALS
DATE
SIZE
REV
CONTRACT NO.
SCALE
SHEET
DRAWN
CHECKED
ISSUED
FSCM NO.
DWG. NO.
D
5
5
4
4
6
6
3
3
7
7
2
2
8
8
1
1
B
C
A
D
B
C
A
D
New Bern, NC 28562
600 Industrial Drive
CT1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
220pF
C39
GND
R49
150
XAI_MCLK
220pF
C111
GND
R63
150
XAI_SCLK
220pF
C66
GND
R61
150
J1
AGND
GND
LO
HI
GND
V+
V-
U1
3
2
1
8
4
OP275
33pF
C15
R6 4.99K
R1
4.99K
C2
33pF
GND
R5 10.0K
R4 10.0K
C1
0.001uF
GND
0.001uF
C14
GND
GND
C10 33pF
R7 4.99K
R2
4.99K
33pF
C4
GND
R8 10.0K
R3 10.0K
0.001uF
C5
GND
0.001uF
C17
GND
LO
HI
L3
L4
U1
7
6
5
OP275
L2
L1
LO
HI
GND
V+
V-
U6
OP275
4
8
1
2
3
33pF
C57
R46 4.99K
R29
4.99K
33pF
C35
GND
R45 10.0K
R44 10.0K
0.001uF
C34
GND
0.001uF
C56
GND
GND
33pF
C53
R47 4.99K
R30
4.99K
33pF
C37
GND
R48 10.0K
R31 10.0K
0.001uF
C38
GND
0.001uF
C59
GND
LO
HI
L7
L8
U6
OP275
5
6
7
L6
L5
C12
22uF
C11
22uF
22uF C55
22uF C54
LO
HI
GND
V+
V-
-2dBu
U11
3
2
1
8
4
OP275
33pF
C102
R65 4.99K
R58
4.99K
33pF
C82
GND
R64 10.0K
R62 10.0K
0.001uF
C81
GND
0.001uF
C101
GND
GND
33pF
C94
R66 4.99K
R59
4.99K
33pF
C84
GND
R67 10.0K
R60 10.0K
0.001uF
C85
GND
0.001uF
C104
GND
LO
HI
L11
L12
U11
7
6
5
OP275
L10
L9
LO
HI
GND
V+
V-
U17
OP275
4
8
1
2
3
33pF
C146
R114 4.99K
R100
4.99K
33pF
C133
GND
R113 10.0K
R104 10.0K
0.001uF
C132
GND
0.001uF
C145
GND
GND
33pF
C138
R115 4.99K
R101
4.99K
33pF
C135
GND
R116 10.0K
R102 10.0K
0.001uF
C136
GND
0.001uF
C148
GND
LO
HI
L15
L16
U17
OP275
5
6
7
L14
L13
22uF C96
22uF C95
22uF C140
22uF C139
-2dBu
-2dBu
-2dBu
-2dBu
-2dBu
-2dBu
-2dBu
DB1
DB2
DB3
DB4
DB5
DB6
DB7
DB8
DB9
DB10
DB11
DB12
DB14
DB15
DB16
DB17
DB18
DB19
DB20
DB21
DB22
DB23
DB24
DB25
DB13
CT2
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
V+
V-
GND
100uF
C137
100uF
C13
0.1uF
C3
0.1uF
C16
0.1uF
C36
0.1uF
C58
0.1uF
C83
0.1uF
C103
0.1uF
C134
0.1uF
C147
0.1uF
C105
0.1uF
C42
0.1uF
C107
0.1uF
C48
0.1uF
C106
0.1uF
C45
0.1uF
C108
0.1uF
C51
0.1uF
C64
100uF
C52
Q1
3
1
LT1117
2
GND
IN
OUT
0.1uF
C79
100uF
C109
GND
+3.3V
VCC
F3
1.0A
POLYSW
POLYSW
1.0A
F2
F1
0.3A
POLYSW
1uF
C65
1uF
C80
U12
19
1
11
12
13
14
15
16
17
18
9
8
7
6
5
4
3
2
74LCX245
B1
B2
B3
B4
B5
B6
B7
B0
A1
A2
A3
A4
A5
A6
A7
T/R
___
A0
OE
__
+3.3V
GND
0.1uF
C110
F4
POLYSW
1.0A
R103
4.99K
GND
LINE4RT_AI_HI
AGND
LINE4LT_AI_LO
LINE3RT_AI_HI
AGND
LINE3LT_AI_LO
LINE2RT_AI_HI
AGND
LINE2LT_AI_LO
LINE1RT_AI_HI
AGND
LINE1LT_AI_LO
LINE4RT_AI_LO
LINE4LT_AI_HI
AGND
LINE3RT_AI_LO
LINE3LT_AI_HI
AGND
LINE2RT_AI_LO
LINE2LT_AI_HI
AGND
LINE1RT_AI_LO
LINE1LT_AI_HI
AGND
AGND
LINE1LT_AI_HI
LINE1LT_AI_LO
LINE1RT_AI_HI
LINE1RT_AI_LO
LINE2RT_AI_HI
LINE2RT_AI_LO
LINE2LT_AI_LO
LINE2LT_AI_HI
LINE1LT
LINE1RT
LINE2LT
LINE2RT
LINE3LT_AI_HI
LINE3LT_AI_LO
LINE3RT_AI_HI
LINE3RT_AI_LO
LINE4RT_AI_HI
LINE4RT_AI_LO
LINE4LT_AI_LO
LINE4LT_AI_HI
LINE3LT
LINE3RT
LINE4LT
LINE4RT
ADI_SDATA1
ADI_SDATA2
ADI_SDATA3
ADI_SDATA4
+5VDin
V+in
V-in
AGND
GND
GND
GND
GND
GND
AGND
AI_SCLK
V-in
V+in
GND
GND
V+in
V-in
AI_MCLK
DI_SCLK
DI_MCLK
AI_SCLK
AI_MCLK
XAI_SCLK
XAI_MCLK
+5VAin
+5VAo
+5VDin
GND
GND
+5VDin
+5VAin
+5VAin
DB-25 CONNECTOR
LINE 2
LINE 1
LINE 4
LINE 3
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
New Bern, NC 28562
600 Industrial Drive
WWP/SA
AINC-4 PCB
W# 700847
2 OF 2
80S1001-2
AINC-4
9-7-05
page 4 - 3
E-Series Network / Apr 2007
SA
SA
- SA UR US - Sergey Averin -
APPROVALS
DATE
SIZE
REV
CONTRACT NO.
SCALE
SHEET
DRAWN
CHECKED
ISSUED
FSCM NO.
DWG. NO.
D
_
5
5
4
4
6
6
3
3
7
7
2
2
8
8
1
1
B
C
A
D
B
C
A
D
VA+_1
3V_1
0.001uF
C97
0.001uF
C40
GND
GND
.1uF
C60
.1uF
C86
-14dBu
-14dBu
10uF
C112
V+
V-
V+
V-
GND
GND
10uF
C26
GND
D10
BAT54
D9
BAT54
GND
BAT54
D2
BAT54
D1
GND
GND
GND
GND
0.1uF
C27
GND
GND
0.1uF
C113
R54
4.99K
0.001uF C124
0.001uF C114
0.001uF C19
0.001uF C41
R79
332
R80
51
R81
1.00K
R76
15
R68
1.00K
R77
15
R9
15
R10
15
R34
51
R69
51
R12
51
R11
1.00K
R13
1.00K
R33
332
U13
3
2
1
8
4
OP275
3
2
1
8
4
OP275
U2
U13
7
6
5
OP275
7
6
5
OP275
U2
-14dBu
-14dBu
0.1uF
C87
GND
GND
R106
1.00K
R105
1.00K
GND
0.1uF
C18
GND
GND
0.1uF
C125
GND
2.5V_1
VA+_1
0.1uF
C141
0.1uF
C68
GND
150uF
C67
Z2
1N4735
6.2V
+3.3V
R50 51
L17
150uF
C69
C6
150uF
D9
BAT54
D10
BAT54
BAT54
D2
BAT54
D1
VA+_1
3V_1
2.5V_1
2.5V_1
2.5V_1
2.5V_1
3V_1
3V_1
3V_1
VA+_2
3V_2
0.001uF
C98
0.001uF
C43
GND
GND
.1uF
C61
.1uF
C88
10uF
C115
V+
V-
V+
V-
GND
GND
10uF
C28
GND
D12
BAT54
D11
BAT54
GND
D4
BAT54
D3
BAT54
GND
GND
GND
GND
0.1uF
C29
GND
GND
0.1uF
C116
R55
4.99K
0.001uF C126
0.001uF C117
0.001uF C21
0.001uF C44
R85
332
R86
51
R87
1.00K
R82
15
R70
1.00K
R83
15
R14
15
R15
15
R37
51
R71
51
R17
51
R16
1.00K
R18
1.00K
R36
332
U14
3
2
1
8
4
OP275
U3
3
2
1
8
4
OP275
U14
7
6
5
OP275
U3
7
6
5
OP275
0.1uF
C89
GND
GND
R108
1.00K
R107
1.00K
GND
0.1uF
C20
GND
GND
0.1uF
C127
GND
2.5V_2
VA+_2
0.1uF
C142
0.1uF
C71
GND
150uF
C70
1N4735
6.2V
Z4
+3.3V
R51 51
L18
150uF
C72
C7
150uF
D11
BAT54
D12
BAT54
D4
BAT54
D3
BAT54
VA+_2
3V_2
2.5V_2
2.5V_2
2.5V_2
2.5V_2
3V_2
3V_2
3V_2
VA+_3
3V_3
0.001uF
C99
0.001uF
C46
GND
GND
.1uF
C62
.1uF
C90
10uF
C118
V+
V-
V+
V-
GND
GND
10uF
C30
GND
D14
BAT54
D13
BAT54
GND
D6
BAT54
D5
BAT54
GND
GND
GND
GND
0.1uF
C31
GND
GND
0.1uF
C119
R56
4.99K
0.001uF C128
0.001uF C120
0.001uF C23
0.001uF C47
R91
332
R92
51
R93
1.00K
R88
15
R72
1.00K
R89
15
R19
15
R20
15
R40
51
R73
51
R22
51
R21
1.00K
R23
1.00K
R39
332
U4
3
2
1
8
4
OP275
U15
7
6
5
OP275
U4
7
6
5
OP275
0.1uF
C91
GND
GND
R110
1.00K
R109
1.00K
GND
0.1uF
C22
GND
GND
0.1uF
C129
GND
2.5V_3
VA+_3
0.1uF
C143
0.1uF
C74
GND
150uF
C73
1N4735
6.2V
Z6
+3.3V
R52 51
L19
150uF
C75
C8
150uF
D13
BAT54
D14
BAT54
D6
BAT54
D5
BAT54
VA+_3
3V_3
2.5V_3
2.5V_3
2.5V_3
2.5V_3
3V_3
3V_3
3V_3
VA+_4
3V_4
0.001uF
C100
0.001uF
C49
GND
GND
.1uF
C63
.1uF
C92
10uF
C121
V+
V-
V+
V-
GND
GND
10uF
C32
GND
D16
BAT54
D15
BAT54
GND
D8
BAT54
D7
BAT54
GND
GND
GND
GND
0.1uF
C33
GND
GND
0.1uF
C122
R57
4.99K
0.001uF C130
0.001uF C123
0.001uF C25
0.001uF C50
R97
332
R98
51
R99
1.00K
R94
15
R74
1.00K
R95
15
R24
15
R25
15
R43
51
R75
51
R27
51
R26
1.00K
R28
1.00K
R42
332
U16
3
2
1
8
4
OP275
U5
3
2
1
8
4
OP275
U16
7
6
5
OP275
U5
7
6
5
OP275
0.1uF
C93
GND
GND
R112
1.00K
R111
1.00K
GND
0.1uF
C24
GND
GND
0.1uF
C131
GND
2.5V_4
VA+_4
0.1uF
C144
0.1uF
C77
GND
150uF
C76
Z8
1N4735
6.2V
+3.3V
R53 51
L20
150uF
C78
C9
150uF
D15
BAT54
D16
BAT54
D8
BAT54
D7
BAT54
VA+_4
3V_4
2.5V_4
2.5V_4
2.5V_4
2.5V_4
3V_4
3V_4
3V_4
U7
28
27
26
25
24
23
22
21
20
19
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
18
AK5383
RST
FSYNC
MCLK
SCLK
LRCK
GNDR
AINR-
____
AINR+
ZCAL
AINL-
AINL+
GNDL
SMODE2
SMODE1
DFS
TEST
HPFE
VCOMR
VREFR
VCOML
VREFL
CAL
SDATA
VD
DGND
VA
AGND
BGND
U8
28
27
26
25
24
23
22
21
20
19
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
18
AK5383
RST
FSYNC
MCLK
SCLK
LRCK
GNDR
AINR-
____
AINR+
ZCAL
AINL-
AINL+
GNDL
SMODE2
SMODE1
DFS
TEST
HPFE
VCOMR
VREFR
VCOML
VREFL
CAL
SDATA
VD
DGND
VA
AGND
BGND
U9
28
27
26
25
24
23
22
21
20
19
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
18
AK5383
RST
FSYNC
MCLK
SCLK
LRCK
GNDR
AINR-
____
AINR+
ZCAL
AINL-
AINL+
GNDL
SMODE2
SMODE1
DFS
TEST
HPFE
VCOMR
VREFR
VCOML
VREFL
CAL
SDATA
VD
DGND
VA
AGND
BGND
U10
28
27
26
25
24
23
22
21
20
19
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
18
AK5383
RST
FSYNC
MCLK
SCLK
LRCK
GNDR
AINR-
____
AINR+
ZCAL
AINL-
AINL+
GNDL
SMODE2
SMODE1
DFS
TEST
HPFE
VCOMR
VREFR
VCOML
VREFL
CAL
SDATA
VD
DGND
VA
AGND
BGND
R78 2.32K
R32 2.32K
R84 2.32K
R35 2.32K
R90 2.32K
R38 2.32K
R96 2.32K
R41 2.32K
VA+_2
VA+_1
VA+_3
VA+_4
-14dBu
-14dBu
-14dBu
-14dBu
-14dBu
-14dBu
-14dBu
-14dBu
-14dBu
-14dBu
-14dBu
-14dBu
U15
3
2
1
8
4
OP275
Z1
5.6V
1SMB5919
5.6V
1SMB5919
Z3
5.6V
1SMB5919
Z5
Z7
5.6V
1SMB5919
VA+_2
VA+_1
VA+_3
VA+_4
4
2
3
5
1
PQ05D
Q2
GND
IN
VC
OUT
P4
4
2
3
5
1
PQ05D
Q3
GND
IN
VC
OUT
P4
4
2
3
5
1
PQ05D
Q5
GND
IN
VC
OUT
P4
4
2
3
5
1
PQ05D
Q4
GND
IN
VC
OUT
P4
+5VAo
+5VAo
+5VAo
+5VAo
JP2
JP1
L21
JP4
JP3
L22
JP8
JP7
L24
JP6
JP5
L23
22uF
C149
22uF
C150
22uF
C151
22uF
C152
XAI_MCLK
XAI_SCLK
VREFR1
VREFL1
VCOMR1
VCOML1
ADI_SDATA1
XAI_MCLK
XAI_SCLK
VREFR2
VREFL2
VCOMR2
VCOML2
ADI_SDATA2
XAI_MCLK
XAI_SCLK
VREFR3
VREFL3
VCOMR3
VCOML3
ADI_SDATA3
XAI_MCLK
XAI_SCLK
VREFR4
VREFL4
VCOMR4
VCOML4
ADI_SDATA4
LINE1LT
LINE1RT
LINE2LT
LINE2RT
LINE3LT
LINE3RT
LINE4LT
LINE4RT
page 4 – 2
E-Series Network / Apr 2007
S C H E M A T I C D R A W I N G S
4 Analog Inputs Network I/O Center (AINC-4) - Load Sheet
page 4 – 4
1 OF 2
AONC-4
W# 700848
AONC-4A PCB
80S1002-1
WWP/SA
A
1-29-07
E-Series Network / Apr 2007
page 4 - 5
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
SA
SA
- SA UR US - Sergey Averin -
DATE
SIZE
REV
CONTRACT NO.
SCALE
SHEET
DRAWN
CHECKED
ISSUED
FSCM NO.
DWG. NO.
D
APPROVALS
D
A
C
B
D
A
C
B
New Bern, NC 28562
600 Industrial Drive
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
CT2
GND
R17
150
XAO_MCLK
GND
R18
150
XAO_SCLK
GND
R19
150
J1
AGND
GND
LO
HI
LO
HI
C83
68pF
GND
C69
68pF
GND
C13
68pF
GND
C1
68pF
GND
C58
68pF
GND
C47
68pF
GND
C32
68pF
GND
C23
68pF
GND
C81
68pF
GND
C67
68pF
GND
C15
68pF
GND
C3
68pF
GND
C57
68pF
GND
C46
68pF
GND
C33
68pF
GND
C24
68pF
GND
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
GND
SSM2142
1
2
3
4
5
6
7
8
U1
gnd
V+
V-
-2dBu
-2dBu
-2dBu
-2dBu
-2dBu
-2dBu
-2dBu
-2dBu
GND
SSM2142
8
7
6
5
4
3
2
1
U2
gnd
V+
V-
GND
SSM2142
8
7
6
5
4
3
2
1
U7
gnd
V+
V-
GND
SSM2142
8
7
6
5
4
3
2
1
U8
gnd
V+
V-
GND
SSM2142
U10
8
7
6
5
4
3
2
1
gnd
V+
V-
GND
SSM2142
U11
1
2
3
4
5
6
7
8
gnd
V+
V-
GND
SSM2142
U16
1
2
3
4
5
6
7
8
gnd
V+
V-
GND
SSM2142
U17
1
2
3
4
5
6
7
8
gnd
V+
V-
L5
L1
L6
L2
L9
L7
L10
L8
L13
L11
L14
L12
L17
L15
L18
L16
V+
V-
C84
0.1uF
C70
0.1uF
C4
0.1uF
C16
0.1uF
GND
C82
0.1uF
C68
0.1uF
C14
0.1uF
C2
0.1uF
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
CT1
C18
330pF
C25
330pF
C34
330pF
POLYSW
0.3A
F2
POLYSW
1.0A
F3
POLYSW
0.3A
F1
C21
0.1uF
C17
100uF
LT1117
3
1
2
Q1
OUT IN
GND
C30
0.1uF
C45
100uF
GND
+3.3V
VCC
C22
1uF
C31
1uF
DB1
DB2
DB3
DB4
DB5
DB6
DB7
DB8
DB9
DB10
DB11
DB12
DB14
DB15
DB16
DB17
DB18
DB19
DB20
DB21
DB22
DB23
DB24
DB25
DB13
74LCX245
U9
2
3
4
5
6
7
8
9
18
17
16
15
14
13
12
11
1
19
B1
B2
B3
B4
B5
B6
B7
B0
A1
A2
A3
A4
A5
A6
A7
T/R
___
A0
OE
__
+3.3V
GND
C56
0.1uF
R28
4.99K
GND
POLYSW
1.0A
F4
R16
4.99K
R4
4.99K
R15
100
GND
GND
GND
GND
+3.3V
+3.3V
+3.3V
+3.3V
R3
100
R5
4.99K
R6
100
GND
+3.3V
R14
4.99K
R13
100
GND
+3.3V
4.99K
R7
R2
4.99K
100
R8
R1
100
LINE4RT_AO_HI
AGND
LINE4LT_AO_LO
LINE3RT_AO_HI
AGND
LINE3LT_AO_LO
LINE2RT_AO_HI
AGND
LINE2LT_AO_LO
LINE1RT_AO_HI
AGND
LINE1LT_AO_LO
LINE4RT_AO_LO
LINE4LT_AO_HI
AGND
LINE3RT_AO_LO
LINE3LT_AO_HI
AGND
LINE2RT_AO_LO
LINE2LT_AO_HI
AGND
LINE1RT_AO_LO
LINE1LT_AO_HI
AGND
AGND
AGND
V-in
LINE1LT_AO_HI
LINE3LT_AO_HI
LINE1LT_AO_LO
LINE2LT_AO_HI
LINE4LT_AO_HI
LINE2LT_AO_LO
LINE1RT_AO_HI
LINE3RT_AO_HI
LINE1RT_AO_LO
LINE2RT_AO_HI
LINE4RT_AO_HI
LINE2RT_AO_LO
LINE3LT_AO_LO
LINE4LT_AO_LO
LINE3RT_AO_LO
LINE4RT_AO_LO
OUTPT4RT
OUTPT3RT
OUTPT4LT
OUTPT1LT
OUTPT1RT
OUTPT2LT
OUTPT2RT
OUTPT3LT
V+in
GND
GND
GND
GND
GND
GND
DO_SCLK
DO_MCLK
AGND
GND
V+in
V-in
ADO_SDATA1
ADO_SDATA2
ADO_SDATA3
ADO_SDATA4
AO_MCLK
AO_SCLK
V+in
V-in
+5VDin
DO_C
AO_SCLK
AO_MCLK
XAO_SCLK
XAO_MCLK
DO_CBL
+5VDin
GND
+5VAin
GND
+5VDin
+5VAin
+5VAin
+5VAo
DIF2
DIF1
DIF0
DEM0
DEM1
MUTE
LT
RT
RT
LT
LT
RT
LINE 4
LINE 3
LINE 1
LINE 2
RT
LT
DB-25 CONNECTOR
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
+4dBu BAL
New Bern, NC 28562
600 Industrial Drive
WWP/SA
2 OF 2
80S1002-2
AONC-4A PCB
W# 700848
AONC-4
A
1-29-07
E-Series Network / Apr 2007
page 4 - 6
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
SA
SA
- SA UR US - Sergey Averin -
DATE
SIZE
REV
CONTRACT NO.
SCALE
SHEET
DRAWN
CHECKED
ISSUED
FSCM NO.
DWG. NO.
D
APPROVALS
D
A
C
B
D
A
C
B
GND
GND
GND
C37
22uF
C19
0.1uF
GND
C79
0.1uF
GND
V+
V-
C62
0.1uF
C61
0.1uF
C60
0.1uF
C59
0.1uF
GND
GND
GND
GND
C42
22uF
C20
0.1uF
GND
C80
0.1uF
GND
V+
V-
C66
0.1uF
C65
0.1uF
C64
0.1uF
C63
0.1uF
GND
VA_12
VA_34
PQ05D
Q2
1
5
3
2
4
P4
OUT
VC
IN
GND
PQ05D
Q3
1
5
3
2
4
P4
OUT
VC
IN
GND
C86
1uF
C85
1uF
+5VAo
+5VAo
JP1
JP2
L19
JP3
JP4
L20
GND
GND
GND
GND
GND
GND
GND
AK4396
U3
2
18
17
22
23
24
20
21
16
19
15
1
4
8
28
27
26
25
9
11
10
7
6
5
3
14
13
12
AOUTL-
VREFH
VREFL
AOUTR+
ACKS/DZFR
TST2/CAD1
TST1/DZFL
P/S
VCOM
TTL
PD
___
AOUTR-
AOUTL+
BICK/DCLK
SDATA/DSDL
DEM0/CCLK
DEM1/CDTI
DFS0/CAD0
SMUTE/CSN
MCLK
DIF0/DCLK
DIF1/DSDL
DIF2/DSDR
LRCK/DSDR
AVSS
AVDD
DVSS
DVDD
VA_12
3V_12
GND
GND
GND
GND
GND
GND
GND
GND
V+
V-
C72
390pF
C49
390pF
R61
2.00K
R45
475
C71
390pF
C48
390pF
-2dBu
-2dBu
OP275
U12
7
6
5
OP275
U12
4
8
1
3
2
R53
5.76K
R54
5.76K
C87
3900pF
R62
2.00K
C88
3900pF
R46
475
C35
3900pF
C36
3900pF
R20
2.00K
R21
2.00K
R37
475
R29
5.76K
R30
5.76K
R38
475
R9
1.00K
3V_12
GND
C26 47uF
C5
47uF
C6 47uF
AK4396
U4
12
13
14
3
5
6
7
10
11
9
25
26
27
28
8
4
1
15
19
16
21
20
24
23
22
17
18
2
AOUTL-
VREFH
VREFL
AOUTR+
ACKS/DZFR
TST2/CAD1
TST1/DZFL
P/S
VCOM
TTL
PD
___
AOUTR-
AOUTL+
BICK/DCLK
SDATA/DSDL
DEM0/CCLK
DEM1/CDTI
DFS0/CAD0
SMUTE/CSN
MCLK
DIF0/DCLK
DIF1/DSDL
DIF2/DSDR
LRCK/DSDR
AVSS
AVDD
DVSS
DVDD
VA_12
3V_12
V+
V-
C74
390pF
C51
390pF
R63
2.00K
R47
475
C73
390pF
C50
390pF
-2dBu
-2dBu
OP275
U13
5
6
7
OP275
U13
2
3
1
8
4
R55
5.76K
R56
5.76K
C89
3900pF
R64
2.00K
C90
3900pF
R48
475
C38
3900pF
C39
3900pF
R22
2.00K
R23
2.00K
R39
475
R31
5.76K
R32
5.76K
R40
475
R10
1.00K
3V_12
C27 47uF
C7
47uF
C8 47uF
AK4396
U5
12
13
14
3
5
6
7
10
11
9
25
26
27
28
8
4
1
15
19
16
21
20
24
23
22
17
18
2
AOUTL-
VREFH
VREFL
AOUTR+
ACKS/DZFR
TST2/CAD1
TST1/DZFL
P/S
VCOM
TTL
PD
___
AOUTR-
AOUTL+
BICK/DCLK
SDATA/DSDL
DEM0/CCLK
DEM1/CDTI
DFS0/CAD0
SMUTE/CSN
MCLK
DIF0/DCLK
DIF1/DSDL
DIF2/DSDR
LRCK/DSDR
AVSS
AVDD
DVSS
DVDD
VA_34
3V_34
V+
V-
C76
390pF
C53
390pF
R65
2.00K
R49
475
C75
390pF
C52
390pF
-2dBu
-2dBu
OP275
U14
5
6
7
OP275
U14
2
3
1
8
4
R57
5.76K
R58
5.76K
C91
3900pF
R66
2.00K
C92
3900pF
R50
475
C40
3900pF
C41
3900pF
R24
2.00K
R25
2.00K
R41
475
R33
5.76K
R34
5.76K
R42
475
R11
1.00K
3V_34
C28 47uF
C9
47uF
C10 47uF
AK4396
U6
2
18
17
22
23
24
20
21
16
19
15
1
4
8
28
27
26
25
9
11
10
7
6
5
3
14
13
12
AOUTL-
VREFH
VREFL
AOUTR+
ACKS/DZFR
TST2/CAD1
TST1/DZFL
P/S
VCOM
TTL
PD
___
AOUTR-
AOUTL+
BICK/DCLK
SDATA/DSDL
DEM0/CCLK
DEM1/CDTI
DFS0/CAD0
SMUTE/CSN
MCLK
DIF0/DCLK
DIF1/DSDL
DIF2/DSDR
LRCK/DSDR
AVSS
AVDD
DVSS
DVDD
VA_34
3V_34
V+
V-
C78
390pF
C55
390pF
R67
2.00K
R51
475
C77
390pF
C54
390pF
-2dBu
-2dBu
OP275
U15
7
6
5
OP275
U15
4
8
1
3
2
R59
5.76K
R60
5.76K
C93
3900pF
R68
2.00K
C94
3900pF
R52
475
C43
3900pF
C44
3900pF
R26
2.00K
R27
2.00K
R43
475
R35
5.76K
R36
5.76K
R44
475
R12
1.00K
3V_34
C29 47uF
C11
47uF
C12 47uF
+3.3V
3V_12
L3
+3.3V
3V_34
L4
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
OUTPT1LT
OUTPT1RT
OUTPT2LT
OUTPT2RT
DIF2
DIF1
DIF0
DEM0
DEM1
MUTE
OUTPT3LT
OUTPT3RT
OUTPT4LT
OUTPT4RT
XAO_MCLK
XAO_SCLK
ADO_SDATA1
DIF2
DIF1
DIF0
DEM0
DEM1
MUTE
XAO_MCLK
XAO_SCLK
ADO_SDATA2
DIF2
DIF1
DIF0
DEM0
DEM1
MUTE
XAO_MCLK
XAO_SCLK
ADO_SDATA3
DIF2
DIF1
DIF0
DEM0
DEM1
MUTE
XAO_MCLK
XAO_SCLK
ADO_SDATA4
page 4 – 3
E-Series Network / Apr 2007
S C H E M A T I C D R A W I N G S
4 Analog Outputs Network I/O Center (AONC-4) - Load Sheet
page 4 – 7
1 OF 2
DINC-4
DINC-4A PCB
80S1003-1
E-Series Network / Apr 2007
page 4 - 8
B
C
A
D
B
C
A
D
APPROVALS
D
DWG. NO.
FSCM NO.
ISSUED
CHECKED
DRAWN
SHEET
SCALE
CONTRACT NO.
REV
SIZE
DATE
- SA UR US - Sergey Averin -
SA
SA
5
4
6
3
7
2
8
1
5
4
6
3
7
2
8
1
600 Industrial Drive
New Bern, NC 28562
XDI_MCLK
XDI_SCLK
C20
0.1uF
C9
100uF
Q1
2
1
3
LT1117
OUT
IN
GND
C26
0.1uF
C38
100uF
GND
+3.3V
CT1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
GND
R3
150
GND
R1
150
GND
R2
150
+3.3V
GND
+3.3V
R4
1.00K
U1
13
23
15
6
14
2
11
19
5
10
4
9
1
16
12
18
17
7
20
27
26
28
3
25
24
AD1896
MUTE_I
MCLK_I
WLNGTH_O_1
WLNGTH_O_0
SMODE_O_1
SMODE_O_0
SMODE_I_2
SMODE_I_1
BYPASS
SMODE_I_0
LRCLK_I
SCLK_I
SDATA_I
TDM_I
RESET
______
GRPDLYS
MMODE_I_2
MMODE_I_1
MMODE_I_0
MUTE_O
MCLK_O
LRCLK_O
SCLK_O
SDATA_O
VDD_IO
J1
AGND
GND
C8
330pF
C1
330pF
C2
330pF
GND
R10
220
R11
220
C11 0.1uF
6
4
1
3
T2
GND
GND
+3.3V
+3.3V
L1
U6
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
CS8416
____
TX
C
U
RCBL
96KHZ
AUDIO
NV/RERR
TXSEL0
TXSEL1
RXSEL0
RXSEL1
OLRCK
OSCLK
SDOUT
RMCK
OMCK
RST
VL
VD
VA
RXP3
RXP2
RXP1
RXP0
AGND
DGND
RXN
FILT
______
C22
0.1uF
GND
GND
GND
+3.3V
R36
3.32K
C28 .022uF
C34 0.001uF
GND
R69
4.99K
GND
R37
4.99K
GND
R51
4.99K
GND
C12
22uF
+3.3V
GND
+3.3V
R5
1.00K
U2
24
25
3
28
26
27
20
7
17
18
12
16
1
9
4
10
5
19
11
2
14
6
15
23
13
AD1896
MUTE_I
MCLK_I
WLNGTH_O_1
WLNGTH_O_0
SMODE_O_1
SMODE_O_0
SMODE_I_2
SMODE_I_1
BYPASS
SMODE_I_0
LRCLK_I
SCLK_I
SDATA_I
TDM_I
RESET
______
GRPDLYS
MMODE_I_2
MMODE_I_1
MMODE_I_0
MUTE_O
MCLK_O
LRCLK_O
SCLK_O
SDATA_O
VDD_IO
C21
1uF
C27
1uF
CT2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
F1
1.0A
POLYSW
VCC
DB2
DB5
DB7
DB8
DB9
DB10
DB11
DB12
DB16
DB19
DB20
DB21
DB22
DB23
DB24
DB25
DB13
U10
19
1
2
18
3
17
4
16
5
15
6
14
7
13
8
12
9
11
74LCX245
B1
B2
B3
B4
B5
B6
B7
B0
A1
A2
A3
A4
A5
A6
A7
T/R
___
A0
OE
__
+3.3V
GND
C39
0.1uF
R77
100
GND
R78
4.99K
+3.3V
+3.3V
R62
4.99K
GND
R49
4.99K
GND
R70
1.00K
+3.3V
R61
1.00K
R32
100
R12
40.2K
GND
R20
4.99K
+3.3V
R16
100
GND
R24
4.99K
+3.3V
R45
1.00K
+3.3V
GND
R8
220
R9
220
C10 0.1uF
T1
3
1
4
6
GND
GND
+3.3V
+3.3V
L2
U7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
CS8416
____
TX
C
U
RCBL
96KHZ
AUDIO
NV/RERR
TXSEL0
TXSEL1
RXSEL0
RXSEL1
OLRCK
OSCLK
SDOUT
RMCK
OMCK
RST
VL
VD
VA
RXP3
RXP2
RXP1
RXP0
AGND
DGND
RXN
FILT
______
C23
0.1uF
GND
GND
GND
+3.3V
R38
3.32K
C29 .022uF
C35 0.001uF
GND
R71
4.99K
GND
R39
4.99K
GND
R54
4.99K
GND
C13
22uF
R79
100
GND
R80
4.99K
+3.3V
+3.3V
R64
4.99K
GND
R52
4.99K
GND
R72
1.00K
+3.3V
R63
1.00K
R33
100
R13
40.2K
GND
R21
4.99K
+3.3V
R17
100
GND
R25
4.99K
+3.3V
R46
1.00K
+3.3V
GND
R44
4.99K
R50
1.00K
R53
1.00K
GND
+3.3V
U3
4
5
6
74ACT32
U3
7
14
1
2
3
74ACT32
AGND
AGND
LINE4_DI_HI
AGND
LINE3_DI_LO
LINE2_DI_HI
AGND
LINE1_DI_LO
AGND
AGND
LINE4_DI_LO
LINE3_DI_HI
AGND
LINE2_DI_LO
LINE1_DI_HI
AGND
AGND
ADI_SDATA1
XDI_MCLK
XDI_SCLK
LINE1_DI_HI
LINE1_DI_LO
ADI_SDATA2
XDI_MCLK
XDI_SCLK
AGND
GND
GND
GND
GND
GND
AGND
ADI_SDATA1
ADI_SDATA2
ADI_SDATA3
ADI_SDATA4
AI_SCLK
+5VDin
V-in
V+in
GND
GND
V+in
V-in
AI_MCLK
DI_SCLK
DI_MCLK
DI_SCLK
DI_MCLK
XDI_SCLK
XDI_MCLK
+5VDin
GND
GND
+5VDin
+5VAin
+5VAin
LINE2_DI_HI
LINE2_DI_LO
DB-25 CONNECTOR
2 OF 2
E-Series Network / Apr 2007
page 4 - 9
B
C
A
D
B
C
A
D
APPROVALS
D
DWG. NO.
FSCM NO.
ISSUED
CHECKED
DRAWN
SHEET
SCALE
CONTRACT NO.
REV
SIZE
DATE
- SA UR US - Sergey Averin -
SA
SA
5
4
6
3
7
2
8
1
5
4
6
3
7
2
8
1
600 Industrial Drive
New Bern, NC 28562
+3.3V
GND
+3.3V
1.00K
R7
13
23
15
6
14
2
11
19
5
10
4
9
1
16
12
18
17
7
20
27
26
28
3
25
24
U5
AD1896
MUTE_I
MCLK_I
WLNGTH_O_1
WLNGTH_O_0
SMODE_O_1
SMODE_O_0
SMODE_I_2
SMODE_I_1
BYPASS
SMODE_I_0
LRCLK_I
SCLK_I
SDATA_I
TDM_I
RESET
______
GRPDLYS
MMODE_I_2
MMODE_I_1
MMODE_I_0
MUTE_O
MCLK_O
LRCLK_O
SCLK_O
SDATA_O
VDD_IO
+3.3V
GND
+3.3V
1.00K
R6
24
25
3
28
26
27
20
7
17
18
12
16
1
9
4
10
5
19
11
2
14
6
15
23
13
U4
AD1896
MUTE_I
MCLK_I
WLNGTH_O_1
WLNGTH_O_0
SMODE_O_1
SMODE_O_0
SMODE_I_2
SMODE_I_1
BYPASS
SMODE_I_0
LRCLK_I
SCLK_I
SDATA_I
TDM_I
RESET
______
GRPDLYS
MMODE_I_2
MMODE_I_1
MMODE_I_0
MUTE_O
MCLK_O
LRCLK_O
SCLK_O
SDATA_O
VDD_IO
+3.3V
GND
0.1uF
C4
+3.3V
GND
0.1uF
C16
+3.3V
GND
0.1uF
C7
+3.3V
GND
0.1uF
C6
+3.3V
GND
0.1uF
C18
+3.3V
GND
0.1uF
C3
+3.3V
GND
0.1uF
C17
+3.3V
GND
0.1uF
C5
+3.3V
GND
0.1uF
C19
GND
220
R30
220
R31
0.1uF
C33
6
4
1
3
T4
GND
GND
+3.3V
+3.3V
L3
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
U8
CS8416
____
TX
C
U
RCBL
96KHZ
AUDIO
NV/RERR
TXSEL0
TXSEL1
RXSEL0
RXSEL1
OLRCK
OSCLK
SDOUT
RMCK
OMCK
RST
VL
VD
VA
RXP3
RXP2
RXP1
RXP0
AGND
DGND
RXN
FILT
______
0.1uF
C24
GND
GND
GND
+3.3V
3.32K R40
.022uF
C30
0.001uF
C36
GND
4.99K
R73
GND
4.99K
R41
GND
4.99K
R57
GND
22uF
C14
100
R81
GND
4.99K
R82
+3.3V
+3.3V
4.99K
R66
GND
4.99K
R55
GND
1.00K
R74
+3.3V
1.00K
R65
100
R34
40.2K
R14
GND
4.99K
R22
+3.3V
100
R18
GND
4.99K
R26
+3.3V
1.00K
R47
+3.3V
GND
220
R28
220
R29
0.1uF
C32
T3
6
4
1
3
GND
GND
+3.3V
+3.3V
L4
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
U9
CS8416
____
TX
C
U
RCBL
96KHZ
AUDIO
NV/RERR
TXSEL0
TXSEL1
RXSEL0
RXSEL1
OLRCK
OSCLK
SDOUT
RMCK
OMCK
RST
VL
VD
VA
RXP3
RXP2
RXP1
RXP0
AGND
DGND
RXN
FILT
______
0.1uF
C25
GND
GND
GND
+3.3V
3.32K R42
.022uF
C31
0.001uF
C37
GND
4.99K
R75
GND
4.99K
R43
GND
4.99K
R60
GND
22uF
C15
100
R83
GND
4.99K
R84
+3.3V
+3.3V
4.99K
R68
GND
4.99K
R58
GND
1.00K
R76
+3.3V
1.00K
R67
100
R35
40.2K
R15
GND
4.99K
R23
+3.3V
100
R19
GND
4.99K
R27
+3.3V
1.00K
R48
+3.3V
1.00K
R59
1.00K
R56
13
12
11
U3
74ACT32
8
9
10
U3
74ACT32
ADI_SDATA4
XDI_MCLK
XDI_SCLK
ADI_SDATA3
XDI_MCLK
XDI_SCLK
LINE3_DI_HI
LINE3_DI_LO
LINE4_DI_HI
LINE4_DI_LO
page 4 – 4
E-Series Network / Apr 2007
S C H E M A T I C D R A W I N G S
4 Digital Inputs Network I/O Center (DINC-4) - Load Sheet
page 4 – 10