Viavi MTS 2000 Quick Card
Text of the manual
T-BERD®/MTS-2000 Test Set
E4100-series OTDR SMART TEST ASSISTANT
This quick card describes how to connect to a fiber under test, configure SMART TEST OTDR settings,
run tests, and analyze results with a VIAVI T-BERD/MTS-2000 and 4100-series OTDR module.
Equipment Requirements:
• T-BERD/MTS-2000 equipped with the following:
o Fiber Optics Software Release V18.50 or
greater
o E4100 Series OTDR Module
• Fiber optic cleaning and inspection tools
• Launch Cable (minimum 20-meter Fiber optic
patch cable) with connectors matching the OTDR
port and Fiber Under Test
• Optical Coupler to connect Launch Cable to Fiber
Under Test
Figure 1: Equipment Requirements
The following information is required to complete the
test:
• Type of Fiber (Multimode or Single Mode)
• Type of Connectors (SC UPC, SC APC, LC UPC, etc.)
• Distance unit (feet, meters, miles, kilometers)
Fiber Inspection Guidelines:
• Use the VIAVI P5000i or FiberChek Probe
microscope to inspect both sides of every
connection being used (OTDR Port, Launch Cable,
bulkhead connectors, patch cords, etc.)
• Focus the fiber on the screen. If dirty, clean the
connector.
• If it appears clean, run inspection test.
• If it fails, clean the fiber and re-run inspection
test. Repeat until it passes.
Figure 2: Inspect Before You Connect (IBYC)
Connect Launch Cable to OTDR port:
1. Inspect the OTDR port on top of the test set.
2. Inspect the fiber end face of Launch Cable.
3. Connect Launch Cable to the OTDR port.
Launch and Configure Smart Test:
1. Press the Power button
to start the test
set.
2. Press the Home button
to display the
Home view with the SMART TEST icon.
3. Tap the SMART TEST icon until it is yellow and
highlighted
.
4. Select a configuration file:
• Select the EXPRESS configuration file to
setup the T-BERD for 5 second acquisitions
to quickly confirm loss and distance.
• Select the CERTIFICATION configuration file
to setup for 20 second acquisitions to
confirm loss and distance AND analyze all
events (slices, connectors, etc.)
• Tap
to select a user configuration file
stored in the /disk/fiber/config folder.
5. Tap
to view the SMART TEST Setup
screen.
6. Laser: Tap the desired wavelength(s) to test.
Select 2 wavelengths to detect bends.
7. Distance Unit: Tap the desired unit of
measure for the launch cable.
8. Launch Cable:
a. Tap YES if you are using a Launch Cable.
b. Tap the
icon to enter or measure the
Launch Cable length.
c. If the launch cable length is known, tap
to
clear existing text, enter new value on the
keypad and tap
to return.
d. To measure the launch cable length, tap
Measure and tap Confirm. The measured value
will auto-populate when measurement is
finished.
Note: The Launch Cable should not be connected
to the Fiber Under Test during measurement.
9. Alarms: Choose User for Viavi recommended
Pass/Fail limits.
10. Distance Unit: If you wish to use a different
unit of measure for the test results, change
the unit of measure to the desired value.
Figure 3: Home screen
Figure 4: SMART TEST Configuration File
Figure 5: SMART TEST Setup
Figure 6: Launch Cable Setup
Connect to Fiber Under Test (FUT):
The Launch Cable may be connected to the FUT
via an optical patch panel (OPP) or an optical
coupler:
1. If the interface to the FUT is a patch cord,
connect the patch cord to an optical coupler with
the same connector type.
2. Inspect the FUT connected to the coupler or
OPP.
3. Inspect the other fiber end face of the Launch
Cable.
4. Connect the Launch Cable to the coupler or OPP.
Run Test:
1. Tap
to start the test. After auto-
configuration, the OTDR will perform a
connection check to ensure that the connection
is Good. If the Connection is Bad, disconnect the
launch cable, repeat steps 1 through 3 on page 1,
and repeat steps 1 through 4 above on page 3,
ensuring all fiber end faces are clean.
2. The T-BERD/MTS will perform acquisitions at the
configured wavelengths. Overall test results
(Pass or Fail) will be displayed in a pop-up
window. Tap the window to close it.
3. Results can be viewed in 2 formats.
Tap the
softkey to toggle views.
Figure 7: Connecting the Launch Cable to the FUT with a coupler
Figure 8: Connecting the Launch Cable to an OPP
Figure 9: Connection Check
• SmartLink view: The FUT is displayed as a
series of icons representing each event
(connector, splice, bend, etc.). The center of
the display (Link Table) shows summary
results for the entire span. Acquisitions for
which all events are acceptable are marked
with a green check
. Acquisitions with
events that exceed pass/fail thresholds for
loss or reflectance are marked with a red
.
The lower display (Alarms) shows each event
that exceeds thresholds. Softkeys can be used
to alter the display:
•
Tap any icon in the upper display to
show detailed results for the event.
•
Detailed results are shown for all
events.
Figure 10: SmartLink View
Contact Us +1 844 GO VIAVI
(+1 844 468 4284)
To reach the VIAVI office nearest you,
visit viavisolutions.com/contacts.
© 2020 VIAVI Solutions Inc.
Product specifications and descriptions in this
document are subject to change without notice.
• Trace view: Results for each wavelength are
shown in different colors in the top of the
display. Each event is listed in the lower
display. Any events that violate pass/fail
thresholds for loss or reflectance are RED.
Use the right and left arrow keys
to
toggle between results for each wavelength.
Tap the Zoom soft key
to enable the
following zoom controls:
•
Toggle between automatic zoom and
full trace view
•
Expand and contract the trace.
Figure 11: Trace View
4. Tap the Save softkey
to view File
Recording Information.
5. Enter Fiber Id, Fiber Number, Locations, and Job
ID as follows:
• Tap field to open keyboard
• Tap
to clear existing text.
• Enter desired value.
• Tap
icon to return.
Note: The Job ID field identifies the Job ID and
creates a folder to save the result by the same
name. The default save location is JOB folder
under disk.
6. Tap
to save the trace in .sor format. Tap
to save the trace in .sor and .pdf format.
One file is saved per wavelength.
Figure 12: Recording Information
7. The T-BERD/MTS will return to the OTDR results
screen.
8. Tap the Assistant soft key
to return to the
SMART TEST Setup menu.
9. Repeat all steps on pages 3 and 4 for all Fibers
under test.
Figure 13: SMART TEST Setup