VARILITE ICON BACK SYSTEM Operation & User’s Manual
Read Online
Read the VARILITE ICON BACK SYSTEM Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
IMPORTANT PRODUCT INFORMATION
ICON™ BACK SYSTEM
WITH VARILOCK™ HARDWARE
USER MANUAL
Important Note for Dealers:
Please provide the User or
Caregiver with this manual.
Important Note for ICON
Back System Users and
Caregivers: Please keep this
manual for future reference.
If you do not understand
this instruction manual or
if you have any questions,
please contact VARILITE
Customer Service at
(800) 827-4548 or
(206) 505-9500.
®
Thoracic Support Instructions
page 10
Care and Maintenance
page 11
Warranty
page 12
Important Note for Suppliers: Please provide the User or Caregiver
with this manual.
Important Note for Icon Back System Users and Caregivers: Please
keep this manual for future reference.
If you do not understand this User Manual or if you have
any questions, please contact VARILITE Customer Service at
800.827.4548 or 206.505.9500.
This User Manual explains how to care for, maintain, and adjust
your Icon Back System.
Table of Contents
Installation and adjustment of your Icon Back
System should be performed only by an
authorized dealer or qualified therapist.
Failure to use the appropriate equipment for
restraint in a vehicle can result in serious injury
or death.
• Never use your Icon Back System if any
hardware is missing, malfunctioning, or broken.
Seek qualified assistance with any repairs or
adjustments.
• Never exceed the weight capacity of the back
support.
The maximum user weight for systems less
than 22 in. (55 cm) wide is 300 lbs (136 kg). The
maximum user weight for systems 22 in. (55 cm)
or greater is 400 lbs (181 kg).
WARNING
TO AVOID INJURY, read, understand and follow all instructions
and warnings in this manual before using your Icon Back System.
There are hazards associated with the use of wheelchairs and
adaptive equipment. If you misuse your wheelchair or your back
support you can be seriously injured.
• Never exceed the weight capacity of the wheelchair
as specified by the wheelchair manufacturer.
• Never perform weight training that causes you to
exceed the weight capacity of the wheelchair.
• Do not exceed the weight capacity of the
wheelchair during other activities of daily living.
• Never lift the wheelchair by the back support.
• Never use the back support without its cover, the
cover is made with flame retardant materials.
Using the back support without its cover increases
the risk of flammability.
• Never modify your Icon Back System or use it in a
way not described by these instructions.
WARNING
WARNING
Do not leave Slide Caps in the open position. Doing so may
allow the Slide Brackets to disengage from the Holsters,
causing the back support to accidentally fall out, which can
result in serious injury.
Icon Back Systems are designed to be compatible with most
wheelchairs, noting the following exceptions:
The system can be used only with wheelchairs with
cane diameters equal to 1 in. (25 mm) or less.
The system can be used only with wheelchairs with
round canes.
Wheelchairs are not required to have stabilizer bars,
provided the canes can maintain their position.
Only use wheelchairs with round canes equal to 1 in.
(25mm) or less in diameter.
Failure to use compatible equipment can result in
equipment breakage and serious injury.
This seating system has been dynamically tested and meets
requirements of ANSI WC20/Vol4 and conforms to ISO 16840-4 for the
safe use of seating devices for use in motor vehicles when used with
a wheelchair base that complies with performance requirements of
ANSI WC19 or ISO 7176-19.
A surrogate wheelchair base and Hybrid III Midsize Male ATD were
used in the frontal impact test.
Any postural support devices and belts that have not been
successfully tested in accordance with ANSI/RESNA WC18 or WC19
should not be relied upon as an occupant restraint in a vehicle.
Failure to use the appropriate equipment for restraint in a vehicle can
result in serious injury or death.
For additional information regarding the use of seating systems in
motor vehicles, refer to Safe Use in a Motor Vehicle provided with this
system and at www.varilite.com.
Use in a Motor Vehicle
For Icon Back System Tall and Icon Back System Deep:
WARNING
Removing the Icon Back System
1.
Depress buttons and slide the right and left Slide
Caps open, away from the Shell. (Fig. 1)
2.
Grab the top of the shell and lift up until the Slide
Bars clear the Holster.* (Fig. 2)
3.
Slide the right and left Slide Caps shut, towards
the Shell.
*Note: When Permanent Mount Screws are engaged the
Slide Brackets cannot be removed from the Holster.
Fig. 1
Fig. 2
Installing Icon Back System
1.
Depress buttons and slide the right and left Slide Caps
open, away from the Shell. (Fig. 3)
2.
Align the Slide Brackets above the track of the Holsters.
3.
Insert the Slide Brackets into the Holsters. (Fig. 4)
4.
Slide the right and left Slide Caps shut, towards the
Shell.
Fig. 3
Fig. 4
To inflate cushion, remove load from cushion.
2.
Open air valve by turning valve counterclockwise.
3.
When cushion is fully inflated, close air valve by turning
valve clockwise.
Adjusting Cushion
1.
To adjust the air level of the Icon Back System Cushion,
begin with the cushion fully inflated and the valve closed.
2.
Position wheelchair user securely in wheelchair.
3.
Turn the valve counterclockwise to open the valve and
release air.
4.
Close the valve when the air level that provides the
support needed for the user’s comfort and functionality is
reached.
Removing Cushion
1.
Pull the cushion up to detach the cover from the shell.
2.
Detach the Handle Flap from the Handle Patch on the
inside of the Shell and pull the Handle Flap through the
slot in the shell.
3.
Remove the back cushion from the attached flap on the
inside of the cover.
Thoracic Support Instructions
Your back system may include optional VARILITE PAL™ Swing-
Away thoracic supports.
To initiate swing, depress the silver button and swing the pad
bracket away from the user. (Fig. 5)
The bracket is locked into place when an auditory click is heard
and the button is fully extended. (Fig. 6)
Fig. 5
Fig. 6
• Wash pad covers in cold water. Air dry.
• Clean metal parts with soft cloth and isopropyl alcohol.
Do not use soap-based products.
• NEVER oil the hinge mechanism.
Operating Instructions: