These instructions contain operating information and should be left with the unit.
ROOM DISTRIBUTION UNITS
Installation & Operation Manual
Edition 3.0
Installation in countries covered by EC Directives:
This product will meet the requirements of the Low Voltage Safety Directive 73 / 23 EEC and the
EMC Directive 89 / 336 EEC when installed in accordance with the instructions contained in this
manual. Failure to comply with these instructions may invalidate the manufacturer's warranty or any
certificate/declaration of conformance requested to be supplied with the unit.
GB
The range of “Room Distribution Units” (RDU’s) are designed to be mounted directly on top of a
“Vapac Steam Humidifier”. Essentially they consist of a stainless steel manifold, and a number of
axial fans contained in a metal box. The steam manifold distributes the steam evenly across the face
of the fans, which blow air over the plumes of steam, in order that the steam is absorbed quickly into
the conditioned space.
Prior to Installing the Vapac Unit & RDU.
•
Check that the unit and RDU installation complies with the minimum dimension requirements
shown in Figure 1 and Table 1 below.
Table 1.
RDU Output (kg/h)
Minimum Distance to Ceiling
0 – 5 kg/h
200 mm
5 – 10 kg/h
250 mm
10 – 30 kg/h
500 mm
30 – 45 kg/h
750 mm
Min. height (See Table 1)
Min. 300 mm
Min.
80 mm
Min. 1000 mm
Access
1000 - 1200
Recommended
Height
Figure 1
Installation – Mounting Instructions.
•
Unpack the RDU, ensuring that all parts/documents are removed prior to discarding the
packaging.
•
Remove the RDU cover by removing the six screws – 3 each side – and lifting the cover clear.
•
Place the RDU on top of the Vapac Unit, so that the steam outlet of the unt and the steam inlet
of the RDU are aligned.
•
Check the position of all other inlet / outlets from / to the unit / RDU, noting any blanking plugs /
knockouts, which need to be removed.
•
Remove the RDU from the unit – remove the blanking plugs / knockouts as necessary.
•
Re-place the RDU on the unit.
•
Secure the RDU in place uning the fixings supplied.
•
Connect the steam hose between the cylinder outlet and the RDU steam inlet, securing each
end with the hose clips provided.
•
Connect the condensate hose to the two condensate drain points of the steam heder, “Tee”
these together using one of the nylon – T’s provided – (see Fig. 2). The second nylon – T should
be used to connect the combined condensate drain into the feed line between the “tundish fill
cup” and the feed drain manifold – approximately 1/3 of the way up from the manifold – (see Fig.
2).
•
Connect the electrical supply to the fans, 230 V~ live from terminal 25, and 230 ~ neutral from
terminal 26. The earth should be connected between the RDU (earth stud) and Unit (earth rail).
•
Replace the RDU cover, and secure in place with the six screws removed earlier.
Figure 2
Head Cover 2
5
BZA954-6
BZA954-7
BZA954-6
BZA954-7
BZA954-6
BZA954-6
BZA954-8
BZA954-9
RDU Grill
6
BZB098-05
BZB098-01
BZB098-05
BZB098-01
BZB098-07
BZB098-03
BZB098-04
BZB098-09
Fan Support
7
BZB099-05
BZB099-01
BZB099-05
BZB099-01
BZB099-07
BZB099-03
BZB099-04
BZB099-09
Top Grill Locator
8
BZB096-05
BZB096-01
BZB096-05
BZB096-01
BZB096-07
BZB096-03
BZB096-04
BZB096-09
Back Cover
9
BZB095-05
BZB095-01
BZB095-05
BZB095-01
BZB095-07
BZB095-03
BZB095-04
BZB095-09
Top Cover
10
2 x 3010034
2 x 3010034
3 x 3010034
3 x 3010034
3 x 3010034
3 x 3010034
5 x 3010034
7 x 3010034 Fan Axial 4650Z PAPST
11
1200100V
1200100V
1200100V
1200100V
1200100V
1200100V
1200100V
1200100V
Trm Block BK2
12
1200430
1200430
1200430
1200430
1200430
1200430
1200430
1200430
Trm ADO Earth D4/6.P.ADO
13
1200431
1200431
1200431
1200431
1200431
1200431
1200431
1200431
Trm ADO Control D4/6.ADO
14
1200437
1200437
1200437
1200437
1200437
1200437
1200437
1200437
TRM Fuse Holder M4/8.SF
15
1200436
1200436
1200436
1200436
1200436
1200436
1200436
1200436
Trm End Section For 1200437
16
1200053V
1200053V
1200053V
1200053V
1200053V
1200053V
1200053V
1200053V
Trm End Brkt EWK (TS32)
17
8210003
8210003
8210003
8210003
8210003
8210003
8210003
8210003
Rail Contr Slotted TS35
Figure 3