Vapac RDU Installation & Operation Manual

Specifications

Brand: Vapac
Category: Fan
Model: RDU (Installation & Operation Manual)
File Type: PDF
File Size: —
Pages: 4

Read Online

Read the Vapac RDU Installation & Operation Manual online using the built-in PDF viewer.

Text of the manual

These instructions contain operating information and should be left with the unit.

ROOM DISTRIBUTION UNITS Installation & Operation Manual Edition 3.0 Installation in countries covered by EC Directives: This product will meet the requirements of the Low Voltage Safety Directive 73 / 23 EEC and the EMC Directive 89 / 336 EEC when installed in accordance with the instructions contained in this manual. Failure to comply with these instructions may invalidate the manufacturer's warranty or any certificate/declaration of conformance requested to be supplied with the unit. GB

The range of “Room Distribution Units” (RDU’s) are designed to be mounted directly on top of a

“Vapac Steam Humidifier”. Essentially they consist of a stainless steel manifold, and a number of axial fans contained in a metal box. The steam manifold distributes the steam evenly across the face of the fans, which blow air over the plumes of steam, in order that the steam is absorbed quickly into the conditioned space. Prior to Installing the Vapac Unit & RDU. • Check that the unit and RDU installation complies with the minimum dimension requirements shown in Figure 1 and Table 1 below. Table 1. RDU Output (kg/h) Minimum Distance to Ceiling 0 – 5 kg/h 200 mm 5 – 10 kg/h 250 mm 10 – 30 kg/h 500 mm 30 – 45 kg/h 750 mm Min. height (See Table 1) Min. 300 mm Min. 80 mm Min. 1000 mm Access 1000 - 1200 Recommended Height Figure 1

Installation – Mounting Instructions.

• Unpack the RDU, ensuring that all parts/documents are removed prior to discarding the packaging. • Remove the RDU cover by removing the six screws – 3 each side – and lifting the cover clear. • Place the RDU on top of the Vapac Unit, so that the steam outlet of the unt and the steam inlet of the RDU are aligned. • Check the position of all other inlet / outlets from / to the unit / RDU, noting any blanking plugs / knockouts, which need to be removed. • Remove the RDU from the unit – remove the blanking plugs / knockouts as necessary. • Re-place the RDU on the unit. • Secure the RDU in place uning the fixings supplied. • Connect the steam hose between the cylinder outlet and the RDU steam inlet, securing each end with the hose clips provided. • Connect the condensate hose to the two condensate drain points of the steam heder, “Tee” these together using one of the nylon – T’s provided – (see Fig. 2). The second nylon – T should be used to connect the combined condensate drain into the feed line between the “tundish fill cup” and the feed drain manifold – approximately 1/3 of the way up from the manifold – (see Fig. 2). • Connect the electrical supply to the fans, 230 V~ live from terminal 25, and 230 ~ neutral from terminal 26. The earth should be connected between the RDU (earth stud) and Unit (earth rail). • Replace the RDU cover, and secure in place with the six screws removed earlier. Figure 2

Head Cover 2

5 BZA954-6 BZA954-7 BZA954-6 BZA954-7 BZA954-6 BZA954-6 BZA954-8 BZA954-9 RDU Grill 6 BZB098-05 BZB098-01 BZB098-05 BZB098-01 BZB098-07 BZB098-03 BZB098-04 BZB098-09 Fan Support 7 BZB099-05 BZB099-01 BZB099-05 BZB099-01 BZB099-07 BZB099-03 BZB099-04 BZB099-09 Top Grill Locator 8 BZB096-05 BZB096-01 BZB096-05 BZB096-01 BZB096-07 BZB096-03 BZB096-04 BZB096-09 Back Cover 9 BZB095-05 BZB095-01 BZB095-05 BZB095-01 BZB095-07 BZB095-03 BZB095-04 BZB095-09 Top Cover 10 2 x 3010034 2 x 3010034 3 x 3010034 3 x 3010034 3 x 3010034 3 x 3010034 5 x 3010034 7 x 3010034 Fan Axial 4650Z PAPST 11 1200100V 1200100V 1200100V 1200100V 1200100V 1200100V 1200100V 1200100V Trm Block BK2 12 1200430 1200430 1200430 1200430 1200430 1200430 1200430 1200430 Trm ADO Earth D4/6.P.ADO 13 1200431 1200431 1200431 1200431 1200431 1200431 1200431 1200431 Trm ADO Control D4/6.ADO 14 1200437 1200437 1200437 1200437 1200437 1200437 1200437 1200437 TRM Fuse Holder M4/8.SF 15 1200436 1200436 1200436 1200436 1200436 1200436 1200436 1200436 Trm End Section For 1200437 16 1200053V 1200053V 1200053V 1200053V 1200053V 1200053V 1200053V 1200053V Trm End Brkt EWK (TS32) 17 8210003 8210003 8210003 8210003 8210003 8210003 8210003 8210003 Rail Contr Slotted TS35 Figure 3