The product is a video and power surge protector device designed according to the standard
of GB/T18802.21-2004/IEC61643-21:200. The device features multi-level protection、high
capacity for through-flow、low limiting voltage、quick reaction time、less insertion loss. It
adapts to overvoltage protection for security video signal and power, protecting the device
from the damage of induced overvoltage, switching overvoltage and static discharge. It’s
widely used in security monitoring system, environment monitoring system.
Please check the following item before installation. If it's missing, please contact the dealer
Surge Protector 1 set
User Manual 1 set
Installation Steps
1) Before inserting the protector into the system, please make sure the grounding grid
reach the specification;
2) please make sure the connection is stable;
3) Please make sure the grounding cable of the surge protector is as short as possible.
Installation
Board Diagram
Power and video Surge Protector
Notice:
1) Please make sure the connection is correct, otherwise it will cause the damage of the
surge protector.
2) Please make sure to check the plug if the consumption is increasing. you can re-connect
it or replace the surge protector
3) Please don't unpack the component personally.
Application
Features
Standard: GB/T18802.21-2004/IEC61643-21:2000;
Protection: Baseband composite video signal(Bandwidth more than 10MHz)、12~24 AC
DC power;
Features: Multifunction multilevel overvoltage protection, large max discharge current,
low limiting voltage, quick reacting time, low insertion loss;
Grounding Mode: Extension Line to ground;
Design: Clear Logo, recognizable, aluminum shell, delicate size, easy installation.
1
2
Video Input
Video Output
Power Input
Power Output
CCTV CAMERA
Coaxial Cable
Power Cable
Coaxial Cable
Power Cable
Surge Protector
Power
Monitor
Power LED
Notice
Please make sure the connection direction is correct.
PE
Grounding
Specification change will not be noticed
3
4
Problem Examination
Item
Description
Video
Working voltage(Un)
12V
Nominal discharge current(In)
3KA
Maximum discharge current(Imax)
5KA
Protection level(Up)
≤40V
Rate
30Mbps
Response time
1ns
Insertion loss
≤0.5dB
Connector
BNC male
Rated load current
DC500mA
Power
Working voltage(Un)
24V
Nominal discharge current(In)
5KA
Maximum discharge current(Imax)
10KA
Protection level (Up)
100V
Response time
25ns
Environmental
Working temperature
-40℃~85℃
Storage temperature
-40℃~75℃
Humidity (non-condensing)
0~95%
Mechanical
Weight
100g
Dimension (L×W×H)
100mm×60mm×38mm
Outer shell
Aluminum
Inspect surge protector
Using multimeter “Ω” measuring input and output wire line resistance is 0Ω;If ,resistance value is
too much ,please replace for a new one.
Using multimeter “ Ω ” measuring wire line resistance to ground wire(yellow green cable), over
400kΩ. If it resistance value is too low, such as 0Ω, please replace for a new one.