AdvisorOne Battery Installation Sheet
EN CNF ES PR
1. Battery
2. Battery Location
English: Installation Sheet
Description
The Advisor™One self-contained lifestyle management and security system detects situations and provides control and information
to home and small business owners (P/N AVO-1037).
This document provides instructions on replacing the rechargeable 7.2 VDC, 2800 mAh NIMH backup battery (P/N AVO-BAT28A)
for use with the AdvisorOne panel.
It is recommended that the backup battery be replaced every 3-5 years or as needed.
Preparation and Installation
Preparing to Install the Battery
WARNING: Use caution when installing or removing the 20JUN14power supply to an outlet with a metal cover.
1.
Depending on the situation, it may be necessary to contact the central monitoring station before starting the installation.
2.
If a power supply is present, remove the screw from the securement tab and unplug the power supply.
3.
Remove the screw securing the panel chassis. Open the panel by pressing down on the tabs and carefully swing the panel
chassis open.
CAUTION: Use static electricity precautions when handling electronic components.
2 / 3
AdvisorOne Battery Installation Sheet
4.
If a battery (A in Figures 1 and 2) is not installed, proceed to “Installing the Battery”. If a battery is currently installed, release
the battery strap (F in Figure 2). Disconnect the battery from the battery connector (D in Figures 1 and 2) by pressing down on
the wire end of the battery clip (E in Figure 1). Remove the existing battery.
Note: Do not dispose of the old battery until the new battery has been installed, tested and is functional. Once the new battery
is tested and is functional, dispose of the old battery in accordance with local regulations.
Installing the Battery
1.
Place the battery in the battery compartment with the wires (B in Figures 1 and 2) facing up as shown. Position the battery so
that the tape (C in Figures 1 and 2) is near the battery connector (D in Figure 2). Secure the battery in position with the battery
strap (F in Figure 2).
2.
Route the battery wires (B in Figures 1 and 2) to the battery connector (D in Figure 2) and place the excess cable in the open
area next to the battery. Do not connect the battery to the battery connector on the panel until step 4.
3. Supply power to the panel as noted in Table 1.
Table 1: Powering the Panel
Installation
Action
Note
US
Plug the power supply into the outlet and secure with the supplied screw.
Canada
Plug the power supply into the outlet.
Do not use the securement tab and screw.
All Other Installations
Follow regional requirements.
Note: Connect the battery within 15 seconds of providing power from the power supply to reduce the potential for a
low battery indication.
4.
Connect the battery to the battery connector on the panel (D in Figure 2). Note that the cable connector (E in Figure 1) locks in
place.
5.
Close the panel, making sure all tabs are engaged. Replace the screw securing the panel chassis.
6.
If the central monitoring station was notified, inform them that this operation is complete.
Upon initial installation, the battery may take up to 48 hours to be fully charged. If the battery is low, a Low Battery icon will be
present and trouble beeps will sound until the battery is sufficiently charged. After the initial charge, should the panel lose power
from the power supply and experience a low battery condition, the icon will appear and trouble beeps will sound unless silenced.
Battery Configuration and Programming
To confirm the battery is supplying power to the panel:
1.
Press the System Status icon .
2.
Verify the Battery icon is displayed in the System Status. If the Battery icon is not displayed, see the “Troubleshooting”
section.
Battery Configuration
At installation, the battery may not be fully charged. To check the battery status, press the System Status icon .
To test the battery:
1.
Press the Settings icon on the lower left of the main screen.
2.
Press CONFIGURATION to enter programming.
3.
Enter installer code or dealer code.
4.
From the Configuration & Programming screen press TEST.
5.
From the Test screen press BATTERY.
6.
To start the battery test, press START. The results will be displayed after the battery test is complete.
Programming
No programming is required.
AdvisorOne Battery Installation Sheet
3 / 3
Troubleshooting
The Battery Connector Will Not Plug into the Board Connector
•
Battery connection is keyed. Slide the clip on the battery connector over the catch (or lock) on the board connector.
•
Ensure there is a secure connection.
The Status Attention Icon Appears and the Panel Indicates a Battery Fault
•
Verify the battery is connected correctly.
•
Check the battery status as noted in the “Battery Configuration” section.
•
If a persistent low battery indication continues for about a week, this may indicate a bad battery. Replace the battery.
Specifications
Dimensions
1.4” wide x 1.3” high x 4.1” deep (35 mm x 32 mm x 105 mm)
Power rating
Rechargeable battery: 7.2 VDC, 2800 mAh NIMH
Storage temperature
14 to 86 ºF (-10 to 30ºC) 90 days shelf life
Operating temperature
32 to 122ºF (0 to 49ºC)
Compatibility
AdvisorOne panel
Contact Information
For general information, see www.interlogix.com. For customer/technical support, see www.interlogix.com/customer-support or call
+1 855 286 8889.
© 2014 United Technologies Corporation. Interlogix is part of UTC Building and Industrial Systems, a unit of United Technologies
Corporation. All rights reserved.
Limitation of Liability
To the maximum extent permitted by applicable law, in no event will Interlogix be liable for any lost profits or business opportunities,
loss of use, business interruption, loss of data, or any other indirect, special, incidental, or consequential damages under any theory
of liability, whether based in contract, tort, negligence, product liability, or otherwise. Because some jurisdictions do not allow the
exclusion or limitation of liability for consequential or incidental damages the preceding limitation may not apply to you. In any event
the total liability of Interlogix shall not exceed the purchase price of the product. The foregoing limitation will apply to the maximum
extent permitted by applicable law, regardless of whether Interlogix has been advised of the possibility of such damages and
regardless of whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions of the authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents, Interlogix
assumes no responsibility for errors or omissions.
Canadian French: Installation Sheet
Translation of the manual into Canadian French.
Spanish: Installation Sheet
Translation of the manual into Spanish.
Portuguese: Installation Sheet
Translation of the manual into Portuguese.