Ubiquiti GBE-LR Quick Start Manual

Text of the manual

Stabilizer Arms (Qty. 2)

Mounting Bracket Screw U-Clamp Flat Washers (Qty. 2) Lock Washers (Qty. 2) Flange Nuts (Qty. 2) Gigabit PoE (24V, 0.5A) with Mounting Bracket Power Cord Package Contents Installation Requirements Clear line of sight between GigaBeam AP and station GBE-LR Quick Start Guide

Vertical mounting orientation

Mounting point: At least 1 m below the highest point on the structure For tower installations, at least 3 m below the top of the tower Outdoor, shielded Category 6 (or above) cabling and shielded RJ45 connectors are required for all wired Ethernet connections. Surge protection should be used for all outdoor installations. We recommend that you use two Ethernet Surge Protectors, model ETH-SP-G2, one near the device and the other at the entry point to the building. The ETH-SP-G2 will absorb power surges and safely discharge them into the ground. Note: For guidelines about grounding and lightning protection, follow your local electrical regulatory codes. Hardware Overview GBE-LR Quick Start Guide

60 GHz LED

5 GHz LED LAN LED Power/Status LED Lights steady blue when the 60 GHz link is ready. Lights steady blue when the 5 GHz link is ready. The LED will light steady blue when an active Ethernet connection is made to the Ethernet port and øash when there is activity. Flashing White Bootup in progress. White Ready for use, not connected to Ubiquiti® Network Management System (UNMS™). See “UNMS GBE-LR Quick Start Guide

PoE IN Port

Reset Button Management”. Blue Ready for use, connected to UNMS. Steady Blue with Occasional Flashing Ready for use, unable to connect to UNMS, check connection to UNMS server. Quickly Flashing Blue Used to locate a device in UNMS. Alternating Blue/White Firmware upgrade in progress. This Gigabit Ethernet port is used to connect the power and should be connected to the LAN and DHCP server. Default IP address: 192.168.1.20. To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on. Alternatively, the device may be reset remotely via a Reset button located on the bottom of the Gigabit PoE Adapter. Installation 1. 2. GBE-LR Quick Start Guide

Attach the stabilizer arms for added support.

(This is recommended for long-range installations.) GBE-LR Quick Start Guide

Note: The GBE-LR can mount on either side of the pole. This section shows the

GBE-LR mounted on the left; the procedure for mounting on the right is similar. OR GBE-LR Quick Start Guide

Note: Rotate the Mounting Bracket clockwise until it locks into position.

6. GBE-LR Quick Start Guide

WARNING: The switch port must comply with the power speciöcations listed in

“Speciöcations”. OR GBE-LR Quick Start Guide

The device is set to DHCP by default, so it will try to automatically obtain an IP address. If that

fails, it will use the default fallback IP address, 192.168.1.20. Proceed to the appropriate section, DHCP or “Fallback IP Address”: DHCP Use one of the following methods: Set up the DHCP server to provide a speciöc IP address to the device based on its MAC address (on the label). Let the device obtain an IP address and then check the DHCP server to see which IP address was assigned. 1. Connect a computer to your network and conögure the Ethernet adapter on your computer with a static IP address on the 192.168.1.x subnet. 2. Launch your web browser. In the address öeld, type: https://192.168.1.20 Then press enter (PC) or return (Mac). 3. Select your Country and Language. You must agree to the Terms of Use to use the product. Click Continue. GBE-LR Quick Start Guide

4. Enter a Username and Password, conörm the Password, and click Save.

5. Click the icon. 6. Conögure the following settings: a. For one device, enable Access Point mode. For the other device (the Station), keep Access Point disabled. b. Enter a name in the SSID öeld. This must be the same on both the AP and the Station. c. In the WPA2 Preshared Key öeld, enter a combination of alphanumeric characters (0-9, A-Z, or a-z). Note: The key is an alphanumeric password between 8 and 63 characters long. GBE-LR Quick Start Guide

7. Click Save Changes.

8. Conögure each device (AP and Station) with a unique IP address: a. Click the icon. b. Review the Network settings to ensure that each device has a unique IP address. Each can get its IP address via DHCP, or use a static IP address. DHCP By default DHCP client is enabled; if there is a DHCP server on your network, the device will receive its address via DHCP. Static Select this option to disable the DHCP client and enter a static IP address. c. Click Save Changes. Fallback IP Address 1. Ensure that your computer (or other host machine) is connected to the same LAN as the GigaBeam. 2. Conögure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet. 3. Launch your web browser. Type https://192.168.1.20 in the address öeld, and press enter (PC) or return (Mac). 4. Select your Country and Language. You must agree to the Terms of Use to use the product. Click Continue. Note: If DHCP client fails, the device will use the fallback IP address: 192.168.1.20 GBE-LR Quick Start Guide

5. Enter a Username and Password, conörm the Password, and click Save.

6. Click the icon. 7. Conögure the following settings: a. For one device, enable Access Point mode. For the other device (the Station), keep Access Point disabled. b. Enter a name in the SSID öeld. This must be the same on both the AP and the Station. c. In the WPA2 Preshared Key öeld, enter a combination of alphanumeric characters (0-9, A-Z, or a-z). Note: The key is an alphanumeric password between 8 and 63 characters long. GBE-LR Quick Start Guide

8. Click Save Changes.

9. Conögure each device (AP and Station) with a unique IP address: a. Click the icon. b. Review the Network settings to ensure that each device has a unique IP address. Each can get its IP address via DHCP, or use a static IP address. DHCP By default DHCP client is enabled; if there is a DHCP server on your network, the device will receive its address via DHCP. Static Select this option to disable the DHCP client and enter a static IP address. c. Click Save Changes. Repeat the instructions in the “Conöguration” section on the other GigaBeam. UNMS Management You can manage your device using UNMS, which lets you conögure, monitor, upgrade, and back up your devices using a single application. Get started at www.unms.com Alignment Tips To accurately align the radios for best performance, you MUST align only one end of the link at a time. You may need to use additional hardware to compensate for issues such as the improper orientation of a mounting pole or signiöcant elevation differences between radios. Establishing a Link Adjust the aim of the AP and the Station to establish a link. Note: If DHCP client fails, the device will use the fallback IP address: 192.168.1.20 GBE-LR Quick Start Guide

Note: The AP must be aimed örst at the Station because the Station does not

transmit any RF signal until it detects transmissions from the AP. 1. AP Visually aim the AP at the Station by loosening the Flange Nuts on the Mounting Bracket to allow adjustments to the azimuth and the elevation. Adjust the azimuth: Adjust the elevation: GBE-LR Quick Start Guide

Note: Do NOT make simultaneous adjustments on the AP and Station.

2. Station Visually aim the Station at the AP. To adjust the Station’s position, adjust the azimuth and elevation as described in step 1. 3. Open the Conöguration Interface. Select Tools and then select Align Antenna. 4. Repeat steps 1-2 until you have achieved an optimal link and both the 60G and 5G LEDs are solidly lit blue. This ensures the best possible data rate between the radios. Note: Maximum signal strength can best be achieved by iteratively sweeping through both azimuth and elevation. 5. Lock the alignment on both radios by tightening all the nuts. 6. Observe the signal level of each radio to ensure that the values remain constant while tightening the nuts. If any value changes during the locking process, loosen the nuts, önalize the alignment of each radio again, and retighten the nuts. Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements. GBE-LR Quick Start Guide

The 5GHz Output Power öeld is provided to the professional installer to assist in meeting

regulatory requirements. Speciöcations GBE-LR Dimensions 415 x 415 x 303 mm (16.34 x 16.34 x 11.93") Weight Without Mount 1.4 kg (3.09 lb) With Mount 1.8 kg (3.97 lb) Enclosure Aluminum, UV-stabilized Polycarbonate Antenna Gain 5 GHz 11 dBi 60 GHz 38 dBi Networking Interface (1) 10/100/1000 Mbps Ethernet Port Max. Power Consumption 11W Power Method Passive PoE, Pins 4, 5+ and 7, 8- Power Supply 24VDC, 0.5A Gigabit PoE Adapter (Included) Voltage Range +22 to +26VDC LEDs Power/Ethernet/5G/60G Wind Loading 56 N @ 200 km/h (12.6 lbf @ 125 mph) Wind Survivability 200 km/h (125 mph) Mounting Pole Mount (Included) ESD/EMP Protection ± 24kV Contact/Air GBE-LR Quick Start Guide

-40 to 60° C (-40 to 140° F)

Operating Humidity 5 to 95% Noncondensing Certiöcations FCC, IC, CE Radio Max. Conducted TX Power 5/60 GHz Combined 25 dBm Channel Bandwidth 60 GHz 2160 MHz 5 GHz 20/40/80 MHz Operating Frequency (MHz) US/CA U-NII-1 5150 - 5250 U-NII-2A 5250 - 5350 U-NII-2C 5470 - 5725 U-NII-3 5725 - 5850 57,000 - 66,000 Worldwide 5180 - 5875 57,000 - 66,000 Management Radio (MHz) Worldwide 2412 - 2472 US/CA 2412 - 2462 Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories speciöed by the manufacturer. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Electrical Safety Information 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those speciöed may result in improper operation, damage to the equipment or pose a öre hazard if the limitations are not followed. 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualiöed service technician. 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. GBE-LR Quick Start Guide

a. Do not substitute the power cord with one that is not the provided approved type. Never use an

adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certiöcation, modiöcation or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a qualiöed electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. Limited Warranty ui.com/support/warranty The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions. Compliance FCC / CAN ICES-3(A)/NMB-3(A) Changes or modiöcations not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules and ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1. l’appareil ne doit pas produire de brouillage; 2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This radio transmitter FCC ID: SWX-GBELR / IC: 6545A-GBELR has been approved by FCC / ISED Canada. The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems. Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur aön de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux. IMPORTANT NOTE: Radiation Exposure Statement: This equipment complies with radiation exposure limits set forth for an uncontrolled environment. GBE-LR Quick Start Guide

This equipment should be installed and operated with minimum distance 110 cm between the

radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. AVIS IMPORTANT : Déclaration sur l’exposition aux rayonnements : Cet équipement est conforme aux limites prévues pour l’exposition aux rayonnements dans un environnement non contrôlé. Lors de l’installation et de la mise en fonctionnement de l’équipement, assurez-vous qu’il y ait une distance minimale de 110 cm entre l’élément rayonnant et vous. Cet émetteur ne doit être installé à proximité d’aucune autre antenne ni d’aucun autre émetteur, et ne doit être utilisé conjointement à aucun autre de ces appareils. Australia and New Zealand Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference. Brazil Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. Country List AT BE BG CY CZ DE DK EE EL ES FI FR HR HU IE IT LV LT LU MT NL PL PT RO SE SI SK UK BFWA (Broadband Fixed Wireless Access) members noted in blue Note: This device meets Max. TX power limit per ETSI regulations. Note: Fixed service or any restrictions for authorization of use shall follow local country regulations. The following apply to products that operate in the 5 GHz frequency range: Note: This device is restricted to indoor use only when operating in the 5150 - 5350 MHz frequency range within all member states. Note: All countries listed may operate at 30 dBm. BFWA member states may operate at 36 dBm. GBE-LR Quick Start Guide

Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states. Other

countries listed may use the 5.8 GHz frequency band. WEEE Compliance Statement Declaration of Conformity Online Resources © 2020 Ubiquiti Inc. All rights reserved. GBE-LR Quick Start Guide

Other Antenna Manuals