Ubiquiti GBE-LR Quick Start Manual
Text of the manual
Stabilizer Arms (Qty. 2)
Mounting Bracket
Screw
U-Clamp
Flat Washers (Qty. 2)
Lock Washers (Qty. 2)
Flange Nuts (Qty. 2)
Gigabit PoE (24V, 0.5A) with
Mounting Bracket
Power Cord
Package Contents
Installation Requirements
Clear line of sight between GigaBeam AP and station
GBE-LR Quick Start Guide
Vertical mounting orientation
Mounting point:
At least 1 m below the highest point on the structure
For tower installations, at least 3 m below the top of the tower
Outdoor, shielded Category 6 (or above) cabling and shielded RJ45 connectors are
required for all wired Ethernet connections.
Surge protection should be used for all outdoor installations. We recommend that you use
two Ethernet Surge Protectors, model ETH-SP-G2, one near the device and the other at the
entry point to the building. The ETH-SP-G2 will absorb power surges and safely discharge
them into the ground.
Note: For guidelines about grounding and lightning protection, follow your local
electrical regulatory codes.
Hardware Overview
GBE-LR Quick Start Guide
60 GHz LED
5 GHz LED
LAN LED
Power/Status LED
Lights steady blue when the 60 GHz link is ready.
Lights steady blue when the 5 GHz link is ready.
The LED will light steady blue when an active Ethernet connection is made to the Ethernet
port and øash when there is activity.
Flashing White
Bootup in progress.
White
Ready for use, not connected to Ubiquiti® Network
Management System (UNMS™). See “UNMS
GBE-LR Quick Start Guide
PoE IN Port
Reset Button
Management”.
Blue
Ready for use, connected to UNMS.
Steady Blue with Occasional
Flashing
Ready for use, unable to connect to UNMS, check
connection to UNMS server.
Quickly Flashing Blue
Used to locate a device in UNMS.
Alternating
Blue/White
Firmware upgrade in progress.
This Gigabit Ethernet port is used to connect the power and should be connected to the
LAN and DHCP server. Default IP address: 192.168.1.20.
To reset to factory defaults, press and hold the Reset button for more than 10 seconds
while the device is powered on. Alternatively, the device may be reset remotely via a Reset
button located on the bottom of the Gigabit PoE Adapter.
Installation
1.
2.
GBE-LR Quick Start Guide
Attach the stabilizer arms for added support.
(This is recommended for long-range installations.)
GBE-LR Quick Start Guide
Note: The GBE-LR can mount on either side of the pole. This section shows the
GBE-LR mounted on the left; the procedure for mounting on the right is similar.
OR
GBE-LR Quick Start Guide
Note: Rotate the Mounting Bracket clockwise until it locks into position.
6.
GBE-LR Quick Start Guide
WARNING: The switch port must comply with the power speciöcations listed in
“Speciöcations”.
OR
GBE-LR Quick Start Guide
The device is set to DHCP by default, so it will try to automatically obtain an IP address. If that
fails, it will use the default fallback IP address, 192.168.1.20. Proceed to the appropriate
section, DHCP or “Fallback IP Address”:
DHCP
Use one of the following methods:
Set up the DHCP server to provide a speciöc IP address to the device based on its MAC
address (on the label).
Let the device obtain an IP address and then check the DHCP server to see which IP
address was assigned.
1. Connect a computer to your network and conögure the Ethernet adapter on your
computer with a static IP address on the 192.168.1.x subnet.
2. Launch your web browser. In the address öeld, type: https://192.168.1.20
Then press enter (PC) or return (Mac).
3. Select your Country and Language. You must agree to the Terms of Use to use the product.
Click Continue.
GBE-LR Quick Start Guide
4. Enter a Username and Password, conörm the Password, and click Save.
5. Click the
icon.
6. Conögure the following settings:
a. For one device, enable Access Point mode. For the other device (the Station), keep
Access Point disabled.
b. Enter a name in the SSID öeld. This must be the same on both the AP and the Station.
c. In the WPA2 Preshared Key öeld, enter a combination of alphanumeric characters (0-9,
A-Z, or a-z).
Note: The key is an alphanumeric password between 8 and 63 characters long.
GBE-LR Quick Start Guide
7. Click Save Changes.
8. Conögure each device (AP and Station) with a unique IP address:
a. Click the
icon.
b. Review the Network settings to ensure that each device has a unique IP address. Each
can get its IP address via DHCP, or use a static IP address.
DHCP By default DHCP client is enabled; if there is a DHCP server on your network,
the device will receive its address via DHCP.
Static Select this option to disable the DHCP client and enter a static IP address.
c. Click Save Changes.
Fallback IP Address
1. Ensure that your computer (or other host machine) is connected to the same LAN as the
GigaBeam.
2. Conögure the Ethernet adapter on your host system with a static IP address on the
192.168.1.x subnet.
3. Launch your web browser. Type https://192.168.1.20 in the address öeld, and press enter
(PC) or return (Mac).
4. Select your Country and Language. You must agree to the Terms of Use to use the product.
Click Continue.
Note: If DHCP client fails, the device will use the fallback IP address:
192.168.1.20
GBE-LR Quick Start Guide
5. Enter a Username and Password, conörm the Password, and click Save.
6. Click the
icon.
7. Conögure the following settings:
a. For one device, enable Access Point mode. For the other device (the Station), keep
Access Point disabled.
b. Enter a name in the SSID öeld. This must be the same on both the AP and the Station.
c. In the WPA2 Preshared Key öeld, enter a combination of alphanumeric characters (0-9,
A-Z, or a-z).
Note: The key is an alphanumeric password between 8 and 63 characters long.
GBE-LR Quick Start Guide
8. Click Save Changes.
9. Conögure each device (AP and Station) with a unique IP address:
a. Click the
icon.
b. Review the Network settings to ensure that each device has a unique IP address. Each
can get its IP address via DHCP, or use a static IP address.
DHCP By default DHCP client is enabled; if there is a DHCP server on your network,
the device will receive its address via DHCP.
Static Select this option to disable the DHCP client and enter a static IP address.
c. Click Save Changes.
Repeat the instructions in the “Conöguration” section on the other GigaBeam.
UNMS Management
You can manage your device using UNMS, which lets you conögure, monitor, upgrade, and
back up your devices using a single application. Get started at www.unms.com
Alignment
Tips
To accurately align the radios for best performance, you MUST align only one end of the
link at a time.
You may need to use additional hardware to compensate for issues such as the improper
orientation of a mounting pole or signiöcant elevation differences between radios.
Establishing a Link
Adjust the aim of the AP and the Station to establish a link.
Note: If DHCP client fails, the device will use the fallback IP address:
192.168.1.20
GBE-LR Quick Start Guide
Note: The AP must be aimed örst at the Station because the Station does not
transmit any RF signal until it detects transmissions from the AP.
1. AP Visually aim the AP at the Station by loosening the Flange Nuts on the Mounting
Bracket to allow adjustments to the azimuth and the elevation.
Adjust the azimuth:
Adjust the elevation:
GBE-LR Quick Start Guide
Note: Do NOT make simultaneous adjustments on the AP and Station.
2. Station Visually aim the Station at the AP. To adjust the Station’s position, adjust the
azimuth and elevation as described in step 1.
3. Open the Conöguration Interface. Select Tools and then select Align Antenna.
4. Repeat steps 1-2 until you have achieved an optimal link and both the 60G and 5G LEDs
are solidly lit blue. This ensures the best possible data rate between the radios.
Note: Maximum signal strength can best be achieved by iteratively sweeping
through both azimuth and elevation.
5. Lock the alignment on both radios by tightening all the nuts.
6. Observe the signal level of each radio to ensure that the values remain constant while
tightening the nuts. If any value changes during the locking process, loosen the nuts,
önalize the alignment of each radio again, and retighten the nuts.
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer’s responsibility to
make sure the device is operated within local country regulatory requirements.
GBE-LR Quick Start Guide
The 5GHz Output Power öeld is provided to the professional installer to assist in meeting
regulatory requirements.
Speciöcations
GBE-LR
Dimensions
415 x 415 x 303 mm (16.34 x 16.34 x 11.93")
Weight
Without Mount
1.4 kg (3.09 lb)
With Mount
1.8 kg (3.97 lb)
Enclosure
Aluminum, UV-stabilized Polycarbonate
Antenna Gain
5 GHz
11 dBi
60 GHz
38 dBi
Networking Interface
(1) 10/100/1000 Mbps Ethernet Port
Max. Power Consumption
11W
Power Method
Passive PoE, Pins 4, 5+ and 7, 8-
Power Supply
24VDC, 0.5A Gigabit PoE Adapter (Included)
Voltage Range
+22 to +26VDC
LEDs
Power/Ethernet/5G/60G
Wind Loading
56 N @ 200 km/h (12.6 lbf @ 125 mph)
Wind Survivability
200 km/h (125 mph)
Mounting
Pole Mount (Included)
ESD/EMP Protection
± 24kV Contact/Air
GBE-LR Quick Start Guide
-40 to 60° C (-40 to 140° F)
Operating Humidity
5 to 95% Noncondensing
Certiöcations
FCC, IC, CE
Radio
Max. Conducted TX Power
5/60 GHz Combined
25 dBm
Channel Bandwidth
60 GHz
2160 MHz
5 GHz
20/40/80 MHz
Operating Frequency (MHz)
US/CA
U-NII-1
5150 - 5250
U-NII-2A
5250 - 5350
U-NII-2C
5470 - 5725
U-NII-3
5725 - 5850
57,000 - 66,000
Worldwide
5180 - 5875
57,000 - 66,000
Management Radio (MHz)
Worldwide
2412 - 2472
US/CA
2412 - 2462
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories speciöed by the manufacturer.
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of
electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the
manufacturer’s label. Connection to a different power source than those speciöed may result in
improper operation, damage to the equipment or pose a öre hazard if the limitations are not followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided only by a
qualiöed service technician.
3. This equipment is provided with a detachable power cord which has an integral safety ground wire
intended for connection to a grounded safety outlet.
GBE-LR Quick Start Guide
a. Do not substitute the power cord with one that is not the provided approved type. Never use an
adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certiöcation, modiöcation
or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualiöed electrician or the manufacturer if there are questions about the installation prior
to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate
short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where
applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC / CAN ICES-3(A)/NMB-3(A)
Changes or modiöcations not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules and ISED Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired
operation.
Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions suivantes :
1. l’appareil ne doit pas produire de brouillage;
2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operations of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This radio transmitter FCC ID: SWX-GBELR / IC: 6545A-GBELR has been approved by FCC / ISED Canada.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for
harmful interference to co-channel mobile satellite systems.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation
à l’intérieur aön de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles
utilisant les mêmes canaux.
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with radiation exposure limits set forth for an uncontrolled environment.
GBE-LR Quick Start Guide
This equipment should be installed and operated with minimum distance 110 cm between the
radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
AVIS IMPORTANT :
Déclaration sur l’exposition aux rayonnements :
Cet équipement est conforme aux limites prévues pour l’exposition aux rayonnements dans un
environnement non contrôlé.
Lors de l’installation et de la mise en fonctionnement de l’équipement, assurez-vous qu’il y ait une
distance minimale de 110 cm entre l’élément rayonnant et vous.
Cet émetteur ne doit être installé à proximité d’aucune autre antenne ni d’aucun autre émetteur, et ne
doit être utilisé conjointement à aucun autre de ces appareils.
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this
equipment may cause radio interference.
Brazil
Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e não pode
causar interferência em sistemas devidamente autorizados.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable
to it.
Country List
AT
BE
BG
CY
CZ
DE
DK
EE
EL
ES
FI
FR
HR
HU
IE
IT
LV
LT
LU
MT
NL
PL
PT
RO
SE
SI
SK
UK
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
Note: Fixed service or any restrictions for authorization of use shall follow local country
regulations.
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the 5150 - 5350 MHz
frequency range within all member states.
Note: All countries listed may operate at 30 dBm. BFWA member states may operate at 36 dBm.
GBE-LR Quick Start Guide
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states. Other
countries listed may use the 5.8 GHz frequency band.
WEEE Compliance Statement
Declaration of Conformity
Online Resources
© 2020 Ubiquiti Inc. All rights reserved.
GBE-LR Quick Start Guide