Tyco Electronics D2950 Instruction Sheet
Text of the manual
25JUL019 Rev. A
D2950 FIELD INSTALLABLE SPRING CLAMP CONNECTOR
© 2019 TE Connectivity Ltd. family of companies.
All Rights Reserved.
| Indicates Change
1 of 8
LOC B
*Trademark. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.
LOC B
1. Introduction
This Instruction Sheet describes the handling method of the D2950 field installable spring clamp
connector (Receptacle Assembly and Header Assembly). Please refer to following Product Specification
for a detailed product performance.
D2950 FIELD INSTLLABLE SPRING CLAMP CONNECTOR Product Specification: 108-140221
2. Composition
Dynamic D2950 is composed of the Receptacle Assembly and the Header Assembly. The circuit symbol
is marked to the Assemblies. Connect cable correctly after symbol confirmation.
Refer to Fig1 for composition
2 of 8
Receptacle Assembly
Header Assembly
Fig. 1 Receptacle Assembly and Header Assembly
䐟
Header Contact
䐠
Retention Leg
䐡
Date Code
䐢
Circuit Mark
3 of 8
3. Instruction of cable connection and extraction
3-1 Cable Strip
䐟Use applicable size cable䠄Fig2䠅. And strip the cable to 8±0.5mm. (Fig3)
䐠If there is twist, bend or feazing. Please correct them. After correcting, check strip length. If there is
excessive deformation, do not use the cable.
䐡Check the cut surface of conductor and insulation are flat.
AWG
Area of conductor [mm2]
AWG22
0.32
AWG20
0.52
AWG18
0.82
AWG16
1.3
AWG14
2.1
※Insulation Diameter 3.8mm Max.
Fig. 2 Applicable Cable
Fig. 3 Strip Length
8±0.5
4 of 8
3-2 Instruction for cable connection (Fig.4)
䐟Set the hook of opener(2347681-1) to the opener hole.
䐠Set the hinge of opener(2347681-1) to the spring slot.
䐡Push the opener(2347681-1) until cable insertion hole opens to the required size.
Do not push strongly, there is possibility of damage to opener (2347681-1) and Receptacle
Assembly.
*About 30N is enough for AWG14 cable.
䐢Insert the cable to cable insertion hole. (Fig.4)
1) Cable insulation Diameter < 2.4mm
The cable should be inserted until aligning cable insulation and end of guiding taper straight line.
2) Cable insulation Diameter ≧ 2.4mm
The cable should be inserted until cable insulation contact the guiding taper.
Opener (2347681-1)
Set hook Set hinge Push opener
Open Cable Insertion Hole Insert cable
Fig.4 cable connection (Cont.)
Opener Hole
Hook
Hinge
Cable Insertion Hole
Spring Slot
5 of 8
Cable insulation Diameter < 2.4mm Cable insulation Diameter ≧ 2.4mm
Completed
Fig.4 cable connection (End)
3-3 Confirmation for cable connection (Fig.5)
Pull the cable softly and confirm that cable does not come off. (Do not pull strongly)
Fig.5 Confirmation
3-4 Cable extraction (Fig.6)
Push the opener until cable guide hole opens to the required size. Extract the cable.
Fig.6 Extract cable
Guiding Taper
Cable Insulation
6 of 8
4. Header Assembly
The Header Assembly is PCB mount Horizontal type.
4-1 Recommended PCB
Through hole type PCB is recommended. Refer to Drawing for layout and thickness.
4-2 Mount Header Assembly to PCB
Insert straight until the Header Assembly is fixed to PCB by retention leg. (Fig.7)
Confirm that there is no float and not tilt. (Fig.8)
Set to PCB Push straightly Completed
Fig.7 Mount to PCB
Fig.8 Bad example
PCB
Retention Leg
Float and Tilt
7 of 8
4-3 Flow solder mounting
This product is lead free correspondence. Please set to appropriate temperature profile.
Refer to Product Specification: 108-140221.
4-4 Soldering by hand work
This product is lead free correspondence. Please set to appropriate temperature.
Refer to Product Specification: 108-140221
5. Mating Receptacle Assembly and Header Assembly (Fig.9)
Insert Receptacle Assembly straightly to Header Assembly until click sound is heard.
*Do not touch the lock lever when inserting.
Insert straightly Completed
Fig.9 Mating
6. Unmating Receptacle Assembly and Header Assembly (Fig.10)
Unmate connector after lock lever is depressed completely.
If unmating connector without lock lever is depressed completely, there is possibility to damage
assemblies, cable and PCB.
Push lock lever completely Pull straightly
7. Others
Completed
Fig.10 Unmating
Lock lever
Lock lever
8 of 8
7. Others
7-1 When using in a place with a lot of vibration, fix the position 100 mm from the Receptacle Assembly.
(Fig.11)
7-2 Avoid mounting to which cable is pulled in excess.
7-3 Don’t use Opener for D3900 and 3950 (1981045-1).
There is possibility of damage the Receptacle Assembly.
Opener Part Number for Dynamic D2950: 2347681-1
Fig.11 Fix position of cable
100mm