TRENDware TEW-431BRP Manual
Read Online
Read the TRENDware TEW-431BRP Manual online using the built-in PDF viewer.
Text of the manual
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
1 of 1
EMC Test Report: CE03111004-A
CE EMC TEST REPORT
according to
EN 301 489-1 V1.4.1 (2002-08) and
EN 301 489-17 V1.2.1 (2002-08)
Applicant
TRENDware International, Inc.
Address
3135 Kashiwa Street, Torrance, CA90505 U.S.A.
Equipment
Cable/DSL 802.11g 54Mbps Wireless Router
Model No.
TEW-431BRP
Trade Name
TRENDware
Power Supply Type
AC Adaptor: Model: MW48-1201000U,
I/P: 230Vac/50Hz; O/P: 12Vdc, 800mA
The test result refers exclusively to the test presented test model / sample.
Without written approval of Exclusive Certification Corp. the test report shall not be reproduced
except in full.
This test report is only applicable to European Community.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
2 of 2
EMC Test Report: CE03111004-A
Contents
CERTIFICATE OF COMPLIANCE.......................................................................................................................4
1.
Definition......................................................................................................................................................5
2.
Test Distance...............................................................................................................................................6
2.1.
Summary of Test Results ...........................................................................................................6
3.
Test of Conducted Powerline.......................................................................................................................7
3.1.
Test Procedures .........................................................................................................................7
3.2.
Typical Test Setup Layout of Conducted Powerline...................................................................8
3.3.
Conducted Emission Requirement ............................................................................................8
4.
Test of Radiated Emission...........................................................................................................................9
4.1.
Test Procedures .........................................................................................................................9
4.2.
Typical Test Setup Layout of Radiated Emission.....................................................................10
4.3.
Radiated Emission Requirement .............................................................................................10
5.
Harmonics Test..........................................................................................................................................11
5.1.
STANDARD..............................................................................................................................11
5.2.
Test Procedure.........................................................................................................................11
6.
Voltage Fluctuations Test...........................................................................................................................12
6.1.
STANDARD..............................................................................................................................12
6.2.
Test Procedure.........................................................................................................................12
7.
Test setup (ESD) .......................................................................................................................................13
7.1.
Test Setup for Tests Performed in Laboratory..........................................................................13
7.2.
Test Procedure.........................................................................................................................14
8.
Test Procedure (RS)..................................................................................................................................15
9.
Test on Power Line (EFT)..........................................................................................................................16
9.1.
Test on Communication Lines..................................................................................................16
9.2.
Test Procedure.........................................................................................................................16
10.
Test Procedure (Surge).....................................................................................................................17
11.
Test Procedure (CS) .........................................................................................................................18
12.
Testing Requirement and Procedure (DIP).......................................................................................19
12.1.
Test Conditions.........................................................................................................................19
12.2.
Operating Condition .................................................................................................................19
13.
Notice for Class A Product................................................................................................................20
14.
Declaration of Conformity and the CE Mark.....................................................................................20
15.
Feature of Equipment under Test .....................................................................................................21
15.1.
History of this test report ..........................................................................................................21
16.
Test Configuration of Equipment under Test.....................................................................................22
16.1.
Test Mode.................................................................................................................................22
16.2.
Description of Test System.......................................................................................................22
17.
Test Software ....................................................................................................................................23
18.
General Information of Test ..............................................................................................................24
18.1.
Description of Major Test Instruments......................................................................................25
19.
Test Result of AC Powerline Conducted Emission ...........................................................................26
19.1.
Test Mode 1 (CH 01b @ 11Mbps Bit-Rate)..............................................................................26
19.2.
Photographs of Conducted Powerline Test Configuration .......................................................44
20.
Test Result of Radiated Emission.....................................................................................................45
20.1.
Test Mode 1 (TX / RX @ 11Mbps Bit – Rate) ..........................................................................45
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
3 of 3
EMC Test Report: CE03111004-A
20.2.
Photographs of Radiated Emission Test Configuration ...........................................................47
21.
Harmonics Test .................................................................................................................................48
22.
Voltage Fluctuations Test..................................................................................................................49
22.1.
TEST EQUIPMENT SETTINGS...............................................................................................49
22.2.
Photographs of Harmonics test, Voltage Fluctuation and Flicker test .....................................50
23.
Electrostatic Discharge Immunity Test (ESD)...................................................................................51
23.1.
Test Severity Levels .................................................................................................................51
23.2.
Test Result of Air Discharge/ Contact Discharge .....................................................................52
23.3.
Photographs of Electrostatic Discharge Immunity Test ...........................................................53
24.
Radio Frequency Electromagnetic Field Immunity Test (RS)...........................................................55
24.1.
Test Severity Levels .................................................................................................................55
24.2.
Photographs of Radio Frequency Electromagnetic Field Immunity Test.................................56
25.
Electrical Fast Transient/Burst Immunity Test (EFT/BURST) ...........................................................57
25.1.
Test Severity Levels .................................................................................................................57
25.2.
Photographs of Electrical Fast Transient/BURST Immunity Test.............................................58
26.
Surge Immunity Test .........................................................................................................................59
26.1.
TEST LEVEL............................................................................................................................59
26.2.
Photographs of Surge Immunity Test.......................................................................................60
27.
Conducted Disturbances Induced by Radio-Frequency Field Immunity Test (CS) ................61
27.1.
TEST LEVEL............................................................................................................................61
27.2.
OPERATING CONDITION.......................................................................................................61
27.3.
Photographs of CS Tests .........................................................................................................62
28.
Voltage Dips and Voltage Interruptions Immunity Tests....................................................................63
28.1.
TEST LEVEL............................................................................................................................63
28.2.
Photographs of Voltage Dips and Voltage Interruptions Immunity Tests .................................64
29.
List of Measuring Equipment Used...................................................................................................65
Appendix A. Photographs of EUT……………………………………..…..………… ……….….……..A1 ~ A4
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
4 of 4
EMC Test Report: CE03111004-A
CERTIFICATE OF COMPLIANCE
according to
EN 301 489-1 V1.4.1 (2002-08) and
EN 301 489-17 V1.2.1 (2002-08)
Applicant
TRENDware International, Inc.
Address
3135 Kashiwa Street, Torrance, CA90505 U.S.A.
Equipment
Cable/DSL 802.11g 54Mbps Wireless Router
Model No.
TEW-431BRP
I HEREBY CERTIFY THAT :
The measurements shown in this test report were made in accordance with the procedures
given in EUROPEAN COUNCIL DIRECTIVE 99/5/EC. The equipment was passed the
test performed according to EN 301 489-1 V1.4.1 (2002-08) and EN 301 489-17 V1.2.1
(2002-08). The test was carried out on Nov. 28, 2003 at Electronics Testing Center, Taiwan.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
5 of 5
EMC Test Report: CE03111004-A
1. Definition
Unintentional radiator:
A device that intentionally generates and radio frequency energy for use within the device, or that sends
radio frequency signals by conduction to associated equipment via connecting wiring, but which is not
intended to emit RF energy by radiation or induction.
Class A Digital Device:
A digital device Which is marketed for use in commercial or business environment; exclusive of a device
which is market for use by the general public, or which is intended to be used in the home.
Class B Digital Device:
A digital device which is marketed for use in a residential environment notwithstanding use in a
commercial, business of industrial environment. Example of such devices that are marketed for the
general public.
Note:
A manufacturer may also qualify a device intended to be marketed in a commercial, business, or
industrial environment as a Class B digital device, and in fact is encouraged to do so, In the event that a
particular type of device has been found to repeatedly cause harmful interference to radio
communications, the Commission may classify such a digital device as a Class B Digital Device,
Regardless of its intended use.
Intentional radiator:
A device that intentionally generates and emits radio frequency energy by radiation or induction.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
6 of 6
EMC Test Report: CE03111004-A
2. Test Distance
a. The test distance of radiated emission test from antenna to EUT is 10 M.
b. The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 M.
2.1. Summary of Test Results
19.1.1 Emission Tests
Measurement
Reference Clause(s)
Test
Reference standard
Radiated emission
8.2
PASSED
EN 55022/A1:2000 class B
Conducted emission
8.3/8.4
PASSED
EN 55022/A1:2000 class B
Harmonic current
emissions
8.5
N/A
EN 61000-3-2:2000
Voltage fluctuations
and flicker
8.6
PASSED
EN 61000-3-3:1995
19.1.2 Immunity Tests
Measurement
Reference Clause(s)
Test
Reference standard
Electrostatic
discharge
9.3
PASSED
EN 61000-4-2:1995/A1:1998
RF electro-magnetic
Field (80-1000 MHz,
1400-2000 MHz.)
9.2
PASSED
EN 61000-4-3:1996/A1:1998
Fast transients
common mode
9.4
PASSED
EN 61000-4-4:1995
Surge
9.8
PASSED
EN 61000-4-5:1995
Radio frequency,
common mode
9.5
PASSED
EN 61000-4-6:1996
Voltage dips and
interrupts
9.7
PASSED
EN 61000-4-11:1994
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
7 of 7
EMC Test Report: CE03111004-A
3. Test of Conducted Powerline
Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz and return leads
of the EUT according to the methods defined in European Standard EN 301 489-17. The EUT was placed
on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section 2.2.
The interface cables and equipment positioning were varied within limits of reasonable applications to
determine the position producing maximum conducted emissions.
3.1. Test Procedures
a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from
the conducting wall of the shielding room and it was kept at least 0.8 meters from any other
grounded conducting surface.
b. Connect EUT to the power mains through a line impedance stabilization network (LISN).
c. All the support units are connect to the other LISN.
d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
e. The CISPR states that a 50 ohm , 50 microhenry LISN should be used.
f.
Both sides of AC line were checked for maximum conducted interference.
g. The frequency range from 150 kHz to 30 MHz was searched
h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold
Mode.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
8 of 8
EMC Test Report: CE03111004-A
3.2. Typical Test Setup Layout of Conducted Powerline
3.3. Conducted Emission Requirement
The equipment under test EUT)shall meet the limits in table 1and 3 or 2 and 4,as applicable,
including the average limit and the quasi-peak limit when using,repectively, an average detector
receiver and quasi-peak detector receiver and measured in accordance with the methods
described in clause 9. Either the voltage limits or the current limits in table 3 or 4, as applicable,
shall be met except for the measurement method of C.1.3 where both limits shall be met. If the
average limit is met when using a qusai-peak decetor reciver, the EUT shall be deemeed to meet
both limits and measurement with the average detector receiver is unnecessary.
If the reading of the measuring receiver shows fluctuations close to the limit, the reading shall be
observed for at least 15 s at each measurement frequency, the higher reading shall be recorded
with the exception of any brief isolated hith reading which shall be ignored.
Limits (dB µ V)
Frequency range
(MHz)
Quasi Peak
Average
0.15 to0.50
66 to 56*
56 to 46*
0.50 to5
56
46
5. to 30.
60
50
NOTE 1-The lower limits shall apply at the transition frequencies.
NOTE 2-The limit decreases linearly with the logarithm of the
frequency in the range 0.15 MHZ to 0.50MHZ.
10cm
80cm
EUT
80cm
40cm
LISN
80cm
40cm
LISN
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
9 of 9
EMC Test Report: CE03111004-A
4. Test of Radiated Emission
Radiated emissions from 30 MHz to 1000 MHz were measured with a bandwidth of 120 kHz according to
the methods defines in European Standard EN 301 489-17. The EUT was placed on a nonmetallic
stand in the open-field site, 0.8 meter above the ground plane, as shown in section 3.2. The interface
cables and equipment positions were varied within limits of reasonable applications to determine the
positions producing maximum radiated emissions.
4.1. Test Procedures
a.
The EUT was placed on a rotatable table top 0.8 meter above ground.
b.
The EUT was set 10 meters from the interference receiving antenna which was mounted on
the top of a variable height antenna tower.
c.
The table was rotated 360 degrees to determine the position of the highest radiation.
d.
The antenna is a half wave dipole and its height is varied between one meter and four meters
above ground to find the maximum value of the field strength both horizontal polarization and
vertical polarization of the antenna are set to make the measurement.
e.
For each suspected emission the EUT was arranged to its worst case and then tune the
antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the
maximum reading.
f.
Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum
Hold Mode.
g.
If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then
testing will be stopped and peak values of EUT will be reported, otherwise, the emissions
which do not have 3 dB margin will be repeated one by one using the quasi-peak method and
reported.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
10 of 10
EMC Test Report: CE03111004-A
4.2. Typical Test Setup Layout of Radiated Emission
4.3. Radiated Emission Requirement
The EUT shall meet limits of tables as below when measured at the measuring distance R in
accordance with the methods described in clause 10. If the reading on the measuring receiver
shows fluctuations close to the limit, the reading shall be observed for at least 15 s at each isolated
high reading, which shall be ignored.
Limit for radiated disturbance of class B ITE at a measuring distance of 10 m
Frequency
(MHz)
Quasi-peak limits
dB (uV/m)
30 to 230
30
230 to 1000
37
Note 1- The lower limit shall apply at the transition frequency.
2- Additional provisions may be required for cases where interference
occurs.
Turn Table
0.8M
Equipment under Test
Ground Plane
Receiver
* Test distance
Antenna
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
11 of 11
EMC Test Report: CE03111004-A
5. Harmonics Test
5.1. STANDARD
z
Product Standard
: EN 61000-3-2:2000
5.2. Test Procedure
As specified on clause 7 and figure Z1 of EN 61000-3-2:2000, the limits are not specified for
equipment with a rated power of 75W or less.
The EUT meets the above condition, so it conforms to EN 61000-3-2.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
12 of 12
EMC Test Report: CE03111004-A
6. Voltage Fluctuations Test
6.1. STANDARD
z
Product Standard
: EN 61000-3-3:1995/A1:2001
6.2. Test Procedure
The equipment shall be tested under the conditions of Clause 5.
The total impedance of the test circuit, excluding the appliance under test, but including the internal
impedance of the supply source, shall be equal to the reference impedance. The stability and
tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of ±8%
is achieved during the whole assessment procedure.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
13 of 13
EMC Test Report: CE03111004-A
7. Test setup (ESD)
HCP
TABLE SIZE
1.6LX0.8WX0.5H m
VCP: 0.5x0.5 m
470K ohm
GRP
470K ohm
470K ohm
470K ohm
10cm
10cm
EUT
1.6mx0.8m
The test setup consists of the test generator, EUT and auxiliary instrumentation necessary to
perform DIRECT and INDIRECT application of discharges to the EUT as applicable, in the follow
manner :
a. CONTACT DISCHARGE to the conductive surfaces and to coupling plane;
b. AIR DISCHARGE at insulating surfaces.
The preferred test method is that of type tests performed in laboratories and the only accepted
method of demonstrating conformance with this standard. The EUT was arranged as closely as
possible to arrangement in final installed conditions.
7.1. Test Setup for Tests Performed in Laboratory
A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper or
aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at least 0.65
mm thickness. In the ELECTRONICS TESTING CENTER., we provided 1 mm thickness aluminum
ground reference plane or 1 mm thickness stainless steel ground reference plane. The minimum size of
the ground reference plane is 1 m x 1 m, the exact size depending on the dimensions of the EUT. It was
connected to the protective grounding system.
The EUT was arranged and connected according to its functional requirements. A distance of 1m
minimum was provided between the EUT and the wall of the lab. and any other metallic structure. In
cases where this length exceeds the length necessary to apply the discharges to the selected points, the
excess length shall, where possible, be placed non-inductively off the ground reference plane and shall
not come closer than 0.2m to other conductive parts in the test setup.
Where the EUT is installed on a metal table, the table was connected to the reference plane via a cable
with a 470k ohm resister located at each end, to prevent a build-up of charge. The test setup was
consist a wooden table, 0.8m high, standing on the ground reference plane. A HCP, 1.6 m x 0.8 m, was
placed on the table. The EUT and cables was isolated from the HCP by an insulating support 0.5 mm
thick. The VCP size, 0.5 m x 0.5 m.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
14 of 14
EMC Test Report: CE03111004-A
7.2. Test Procedure
a. In the case of air discharge testing the climatic conditions shall be within the following ranges:
- ambient temperature: 15
to 35
;
℃
℃
- relative humidity : 30% to 60%;
- atmospheric pressure : 68 KPa (680 mbar) to 106 KPa (1060 mbar).
b. Test programs and software shall be chosen so as to exercise all normal modes of operation of the
EUT. The use of special exercising software is encouraged, but permitted only where it can be
shown that the EUT is being comprehensively exercised.
c. The test voltage shall be increased from the minimum to the selected test severity level, in order to
determine any threshold of failure. The final severity level should not exceed the product
specification value in order to avoid damage to the equipment.
d. The test shall be performed with both air discharge and contact discharge. On preselected points at
least 10 single discharges (in the most sensitive polarity) shall be applied on air discharge. On
preselected points at least 25 single discharges (in the most sensitive polarity) shall be applied on
contact discharge.
e. For the time interval between successive single discharges an initial value of one second is
recommended. Longer intervals may be necessary to determine whether a system failure has
occurred.
f. In the case of contact discharges, the tip of the discharge electrode shall touch the EUT before the
discharge switch is operated.
g. In the case of painted surface covering a conducting substrate, the following procedure shall be
adopted :
If the coating is not declared to be an insulating coating by the equipment manufacturer, then the
pointed tip of the generator shall penetrate the coating so as to make contact with the
conducting substrate.
Coating declared as insulating by the manufacturer shall only be submitted to the air discharge.
The contact discharge test shall not be applied to such surfaces.
h. In the case of air discharges, the round discharge tip of the discharge electrode shall be approached
as fast as possible (without causing mechanical damage) to touch the EUT . After each discharge, the
ESD generator (discharge electrode) shall be removed from the EUT. The generator is then
retriggered for a new single discharge. This procedure shall be repeated until the discharges are
completed. In the case of an air discharge test, the discharge switch, which is used for contact
discharge, shall be closed.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
15 of 15
EMC Test Report: CE03111004-A
8. Test Procedure (RS)
a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The
equipment is then connected to power and signal leads according to pertinent installation instructions.
b. The antenna which is enabling the complete frequency range of 80-1000MHz; 1400-2000 MHz is
placed 3m away from the equipment. The required field strength is determined by placing the field
strength meter(s) on top of or directly alongside the equipment under test and monitoring the field
strength meter via a remote field strength indicator outside the enclosure while adjusting the
continuous-wave to the applicable antennae.
c. The test is normally performed with the antenna facing the most sensitive side of the EUT. The
polarization of the field generated by the biconical antenna necessitates testing each position twice,
once with the antenna positioned vertically and again with the antenna positioned horizontally. The
circular polarization of the field from the log-spiral antenna makes a change of position of the antenna
unnecessary.
d. At each of the above conditions, the frequency range is swept 80-1000 MHz; 1400-2000 MHz,
pausing to adjust the R.F. signal level or to switch oscillators and antenna. The rate of sweep is in the
order of 1.5*10-3 decades/s. The sensitive frequencies or frequencies of dominant interest may be
discretely analyzed.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
16 of 16
EMC Test Report: CE03111004-A
9. Test on Power Line (EFT)
a. The EFT/B-generator was located on the GRP.. The length from the EFT/B-generator to the EUT as
not exceed 1 m.
b. The EFT/B-generator provides the ability to apply the test voltage in a non-symmetrical condition to
the power supply input terminals of the EUT..
9.1. Test on Communication Lines
a. The coupling clamp is composed of a clamp unit for housing the cable (length more than 3 m), and
was placed on the GRP.
b. The coupling clamp provides the ability of coupling the fast transient/bursts to the cable under test.
9.2. Test Procedure
a. In order to minimize the effect of environmental parameters on test results, the climatic
conditions when test is carrying out shall comply with the following requirements:
ambient temperature: 15
to 35
;
℃
℃
relative humidity : 45% to 75%;
atmospheric pressure : 68 Kpa (680 mbar) to 106 Kpa (1060 mbar).
b. In order to minimize the effect of environmental parameters on test results, the electromagnetic
environment of the laboratory shall not influence the test results.
c. The variety and diversity of equipment and systems to be tested make it difficult to establish
general criteria for the evaluation of the effects of fast transients/bursts on equipment and
systems.
d. The test results may be classified on the basic of the operating conditions and the functional
specification of the equipment under test, according to the following performance criteria :
Normal performance within the specification limits.
Temporary degradation or loss of function or performance which is self-recoverable.
Temporary degradation or loss of function or performance which requires operator
intervention or system reset.
Degradation or loss of function which is not recoverable due to damage of equipment
(components).
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
17 of 17
EMC Test Report: CE03111004-A
10. Test Procedure (Surge)
a.
Climatic conditions
The climatic conditions shall comply with the following requirements :
ambient temperature : 15
to 35
℃
℃
relative humidity : 10 % to 75 %
atmospheric pressure : 86 kPa to 106 kPa ( 860 mbar to 1060 mbar )
b.
Electromagnetic conditions
the electromagnetic environment of the laboratory shall not influence the test results.
c.
The test shall be performed according the test plan that shall specify the test set-up with
generator and other equipment utilized;
test level ( voltage/current );
generator source impedance;
internal or external generator trigger;
number of tests : at least five positive and five negative at the selected points;
repetition rate : maximum 1/min.
inputs and outputs to be tested;
representative operating conditions of the EUT;
sequence of application of the surge to the circuit;
phase angle in the case of a.c. power supply;
actual installation conditions, for example :
AC : neutral earthed,
DC : ( + ) or ( - ) earthed to simulated the actual earthing conditions.
d.
If not otherwise specified the surges have to be applied synchronized to the voltage phase at the
zero-crossing and the peak value of the a.c. voltage wave ( positive and negative ).
e.
The surges have to be applied line to line and line(s) and earth. When testing line to earth, the
test voltage has to be applied successively between each of the lines and earth, if there is no other
specification.
f.
The test procedure shall also consider the non-linear current-voltage characteristics of the
equipment under test. Therefore the test voltage has to be increased by steps up to the test level
specified in the product standard or test plan.
g.
All lower levels including the selected test level shall be satisfied. For testing the secondary
protection, the output voltage of the generator shall be increased up to the worstcase voltage
breakdown level ( let-through level ) of the primary protection.
h.
If the actual operating signal sources are not available, the may be simulated. Under no
circumstances may the test level exceed the product specification. The test shall be carried out
according the a test plan.
i.
To find all critical points of the duty cycle of the equipment, a sufficient number of positive and
negative test pulses shall be applied. For acceptance test a previously unstressed equipment
shall be used to the protection devices shall be replaced.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
18 of 18
EMC Test Report: CE03111004-A
11. Test Procedure (CS)
a.
The EUT shall be operated within its intended climatic conditions. The temperature and relative
humidity should be recorded.
b.
This test method test can be performed without using a sell shielded enclosure. This is because
the disturbance levels applied and the geometry of the setups are not likely to radiated a high
amount of energy, especially at the lower frequencies. If under certain circumstances the radiated
energy is too high, a shielded enclosure has to be used.
c.
The test shall be performed with the test generator connected to each of the coupling and
decoupling devices in turn while the other non-excited RF-input ports of the coupling devices are
terminated by a 50 ohm load resistor.
d.
The frequency range is swept from 150 KHz to 230 MHz, using the signal levels established during
the setting process, and with the disturbance signal 80% amplitude modulated with a 1KHz
sinewave, pausing to adjust the RF-signal level or to switch coupling devices as necessary. The
rate of sweep shall no exceed 1.5 x 10-3 decades/s. Where the frequency is swept incrementally,
the step size shall no exceed 1% of the start and thereafter 1% of the preceding frequency value.
e.
The dwell time at each frequency shall not be less than the time necessary for the EUT to be
exercised, and able to respond. Sensitive frequencies e.g. clock frequency(ies) and harmonics or
frequencies of dominant interest shall be analyzed separately.
f.
An alternative test procedure may be adopted, wherein the frequency range is swept incrementally,
with a step size not exceeding 4% of the start ad thereafter 4% of the preceding frequency value.
The test level should be at least twice the value of the specified test level.
g.
In cases of dispute, the test procedure using a step size not exceeding 1% of the start and
thereafter 1% of preceding frequency value shall take precedence.
h.
Attempts should be made to fully exercise the EUT during testing, and to fully interrogate all
exercise modes selected for susceptibility.
i.
The use of special exercising programs is recommended.
j.
Testing shall be performed according to a Test Plan, which shall be included in the test report.
k.
It may be necessary to carry out some investigatory testing in order to establish some aspects of
the test plan.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
19 of 19
EMC Test Report: CE03111004-A
12. Testing Requirement and Procedure (DIP)
The test was based on IEC 61000-4-11 (1994)
12.1. Test Conditions
1. Source voltage and frequency : 230V / 50Hz, Single phase.
2. Test of interval : 10 sec.
3. Level and duration : Sequency of 3 dips/interrupts.
4. Voltage rise (and fall) time : 1 ∼ 5 µs.
5. Test severity :
Voltage dip and
Interrupt reduction (%)
Test Duration
(ms)
30
500
60
100
100
10
100
80
100
5000
12.2. Operating Condition
Full system
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
20 of 20
EMC Test Report: CE03111004-A
13. Notice for Class A Product
This Notice is for class A product only. If the Equipment under Test is a class B product,
this notice should be disregarded.
Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B
ITE limits. Such equipment should not be restricted in its sale but the following warning shall be
included in the instructions for use:
Warning
This is a class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
14. Declaration of Conformity and the CE Mark
There are three possible procedures pertaining to the declaration of conformity:
14.1. Conformity Testing and Declaration of Conformity by the Manufacturer or His
Authorized Representative Established within the Community or by an Importer.
- Article 10 (1) of the EMC Directive, - § 3 (1) no. 2a of the EMC Act.
14.2. Declaration of Conformity Issued by the Manufacturer or His Authorized
Representative Established within the Community or by an Importer Following
Testing of the Product and Issued of an EC certificate of conformity by a
competent body.
- Article 10 (2) of the EMC Directive, - § 3 (1) no. 2b of the EMC Act.
14.3. Declaration of Conformity Issued by the Manufacturer or His Authorized
Representative Established within the Community or by an Importer Following
Testing and Certification of the Product by a Notified Body.
- Article 10 (5) of the EMC Directive,
- § 3 (1) no. 2b of the EMC Act (radio transmitting installations).
14.4. Specimen For The CE Marking Of Electrical / Electronical Equipment
The components of the CE marking shall have substantially the same vertical dimension, which
may not be less than 5 mm.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
21 of 21
EMC Test Report: CE03111004-A
15. Feature of Equipment under Test
The Wireless Router incorporates many advanced features, carefully designed to provide
sophisticated functions while being easy to use.
15.1. History of this test report
The Model No. TEW-431BRP (Report No:CE03111004-A) is the same and it only differs
from the outside cosmetic. The functions and specifications are the same.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
22 of 22
EMC Test Report: CE03111004-A
16. Test Configuration of Equipment under Test
16.1. Test Mode
z The following test mode was performed for conduction test:
z Frequency range investigated: conduction 150 KHz to 30 MHz, radiation 30 MHz to 1000MHz.
16.2. Description of Test System
For Conducted Emission Test and Radiated Emission Test
Product
Manufacturer
Model No.
Serial No.
I/O Cable
Wireless
Broadband Router
TRENDware TEW-431BRP N/A
Non-shielded, 1.2m
Non-shielded, 2.5m
Printer
EPSON
Stylus photo 700
N/A
shielded, 1.2m
Notebook PC
Comoaq
Presario 2800
N/A
Non-shielded, 2.5m
AC Power Cord
Remark “*” means equipment under test.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
23 of 23
EMC Test Report: CE03111004-A
17. Test Software
During testing, “Ping.exe” under WIN 2000 was executed to link with the remote workstation to receive
and transmit data by UTP cable.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
24 of 24
EMC Test Report: CE03111004-A
18. General Information of Test
Test Site
: ELECTRONICS TESTING CENTER, Taiwan
No. 34, Lin 5, Ding Fu Tdun, Linkou Hsiang, Taipei, Taiwan, R.O.C.
Test Voltage
: 230V/ 50Hz
Test in Compliance with
:
EMI Test (conduction and radiation) :
EN 301 489-1 V.1.4.1 (2002-08)
EN 301 489-17 V.1.2.1 (2002-08)
Harmonics Test :
European Standard EN 61000-3-2.
Voltage Fluctuations Test :
European Standard EN 61000-3-3.
EMS Test :
European Standard EN 301 489-1 V.1.4.1 (2002-08).
European Standard EN 301 489-17 V.1.2.1 (2002-08).
ESD: EN 61000-4-2,
RS: EN 61000-4-3,
EFT: EN 61000-4-4,
SURGE: EN 61000-4-5,
CS: EN 61000-4-6,
DIPS: EN 61000-4-11
Frequency Range
Investigated
:
Radiated emission test: from 30 MHz to 1,000 MHz
Radio frequency electromagnetic field immunity test: 80-1000 MHz,
1400-2000 MHz
Test Distance
:
The test distance of radiated emission test from antenna to EUT is
10 M
The test distance of radio frequency electromagnetic field immunity
test from antenna to EUT is 3 M.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
25 of 25
EMC Test Report: CE03111004-A
18.1. Description of Major Test Instruments
(For Conducted)
Test Equipment
Calibration Date
Recommended Recal. Date
Shielded Room\ Riken\---
N.C.R.
N.C.R.
EMI test receiver\R&S\ESCS30
Aug. 10, 2003
Aug. 09, 2004
L.I.S.N.\EMCO\ESH2-Z5
Sep. 22, 2003
Sep. 21, 2004
Monitor\IBM \E54
N.C.R.
N.C.R.
Printer\HP\LaserJet 1000
N.C.R.
N.C.R.
Computer\Acer\Veriton 7500g
N.C.R.
N.C.R.
(For Radiation)
Test Equipment
Calibration Date
Recommended Recal. Date
Amplifier Receiver\HP\8447D
Feb. 20, 2003
Feb. 19, 2004
Bilog Antenna\Chase\CBL6111C
Oct. 29, 2003
Oct. 28, 2004
Pre -selector\HP\85685A
Jan. 02, 2003
Jan. 01, 2004
Spectrum Analyzer\HP\8568B
Jan. 02, 2003
Jan. 01, 2004
Quasi-Peak Adaptor\HP\85650A
Jan. 02, 2003
Jan. 01, 2004
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
26 of 26
EMC Test Report: CE03111004-A
19. Test Result of AC Powerline Conducted Emission
19.1. Test Mode 1 (CH 01b @ 11Mbps Bit-Rate)
Relative Humidity: 70 %
Temperature: 24°C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
(802.11b)
(MHz)
N
L1
N
L1
(dB)
N
L1
N
L1
0.322
41.8
51.7
---
---
0.3
42.1
52
---
---
59.7
49.7
-7.70
---
0.408
42.2
39
---
---
0.3
42.5
39.3
---
---
57.7
47.7
-15.20
---
0.443
44.2
45.2
---
---
0.3
44.5
45.5
---
---
57.7
47.0
-11.50
---
0.785
31.6
46
---
---
0.3
31.9
46.3
---
---
56.0
46.0
-9.70
---
0.84
29.8
33.5
---
---
0.3
30.1
33.8
---
---
56.0
46.0
-22.20
---
0.895
28.4
31.4
---
---
0.3
28.7
31.7
---
---
56.0
46.0
-24.30
---
AVG.
Limit
(dBuV)
Q.P
Value
AVG.
Value
Margins (dB)
Q.P
Factor
Result (dBuV)
Q.P Value AVG. Value
Freq.
Q.P Value
Meter Reading
(dBuV)
AVG. Value
Notes:
1. The EUT was placed 0.8m above reference ground plane.
2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value
doesn’t need to be measured.
3. The expanded uncertainty of the conducted emission tests is 2.45 dB.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
27 of 27
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
28 of 28
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
29 of 29
EMC Test Report: CE03111004-A
19.1.1 Test Mode 2 (CH 07b @ 11Mbps Bit-Rate)
Relative Humidity: 70 %
Temperature: 24°C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
(MHz)
N
L1
N
L1
(dB)
N
L1
N
L1
0.17
56.6
54.1
25.5
23.4
0.2
56.8
54.3
25.7
23.6
65.0
55.0
-8.2
-29.3
0.259
48.5
38.9
21.4
19.9
0.2
48.7
39.1
21.6
20.1
61.5
51.5
-12.7
-29.8
0.459
44.9
46
19.2
22
0.3
45.2
45.3
19.5
22.3
56.7
46.7
-10.4
-24.4
0.855
28.2
33
14.2
10.8
0.3
28.5
33.3
14.5
11.1
56.0
46.0
-22.7
-31.5
1.281
28.7
32
14.7
14.2
0.4
29.1
32.4
15.1
14.6
56.0
46.0
-23.6
-30.9
1.754
19.8
32.1
9.4
10.7
0.5
20.3
32.6
9.9
11.2
56.0
46.0
-23.4
-34.8
AVG.
Limit
(dBuV)
Q.P
Value
AVG.
Value
Margins
(dB)
Q.P
Factor
Result (dBuV)
Q.P Value AVG. Value
Freq.
Q.P Value
Meter Reading
(dBuV)
AVG. Value
Notes:
1. The EUT was placed 0.8m above reference ground plane.
2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value
doesn’t need to be measured.
3. The expanded uncertainty of the conducted emission tests is 2.45 dB.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
30 of 30
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
31 of 31
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
32 of 32
EMC Test Report: CE03111004-A
19.1.2 Test Mode 3 (CH 13b@ 11Mbps Bit-Rate)
Relative Humidity: 70 %
Temperature: 24°C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
(MHz)
N
L1
N
L1
(dB)
N
L1
N
L1
0.373
46
53.3
---
22.6
0.3
46.3
53.6
---
22.9
58.4
48.4
-4.9
-25.6
0.539
38.2
45.2
---
21.8
0.3
38.5
45.5
---
22.1
56.0
46.0
-10.5
-23.9
0.609
35.5
47.5
---
17.7
0.3
35.8
47.8
---
18
56.0
46.0
-8.2
-28
0.789
29.9
42.9
---
21.3
0.3
30.2
43.2
---
21.6
56.0
46.0
-12.8
-24.4
1.004
31.4
34.7
---
11.7
0.3
31.7
35
---
12
56.0
46.0
-21.0
-34
1.07
32.1
33.4
---
10.9
0.3
32.4
33.7
---
11.2
56.0
46.0
-22.3
-34.8
Freq.
Q.P Value
Meter Reading
(dBuV)
AVG. Value
Factor
Result (dBuV)
Q.P Value AVG. Value
AVG.
Limit
(dBuV)
Q.P
Value
AVG.
Value
Margins (dB)
Q.P
Notes:
1. The EUT was placed 0.8m above reference ground plane.
2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value
doesn’t need to be measured.
3. The expanded uncertainty of the conducted emission tests is 2.45 dB.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
33 of 33
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
34 of 34
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
35 of 35
EMC Test Report: CE03111004-A
19.1.3 Test Mode 4 (CH 01g@ 54Mbps Bit-Rate)
Relative Humidity: 70 %
Temperature: 24°C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
802.11g
(MHz)
N
L1
N
L1
(dB)
N
L1
N
L1
0.193
54.7
47.5
24.6
---
0.2
54.9
47.7
24.8
---
63.9
53.9
-9.0
-29.1
0.664
37.6
47.1
18.1
---
0.3
37.9
47.4
18.4
---
56.0
46.0
-8.6
-27.6
0.688
36.8
36.1
12.3
---
0.3
37.1
36.4
12.6
---
56.0
46.0
-18.9
-33.4
0.934
29.9
34.2
17.1
---
0.3
30.2
34.5
17.4
---
56.0
46.0
-21.5
-28.6
1.065
32.3
34.2
11.1
---
0.3
32.6
34.5
11.4
---
56.0
46.0
-21.5
-34.6
1.703
26.8
30.3
22.4
---
0.4
27.2
30.7
22.8
---
56.0
46.0
-25.3
-23.2
Freq.
Q.P Value
Meter Reading
(dBuV)
AVG. Value
Factor
Result (dBuV)
Q.P Value AVG. Value
AVG.
Limit
(dBuV)
Q.P
Value
AVG.
Value
Margins (dB)
Q.P
Notes:
1. The EUT was placed 0.8m above reference ground plane.
2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value
doesn’t need to be measured.
3. The expanded uncertainty of the conducted emission tests is 2.45 dB.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
36 of 36
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
37 of 37
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
38 of 38
EMC Test Report: CE03111004-A
19.1.4 Test Mode 5 (CH 07g @ 54Mbps Bit - Rate)
Relative Humidity: 70 %
Temperature: 24°C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
(MHz)
N
L1
N
L1
(dB)
N
L1
N
L1
0.209
53.3
55.6
22.6
25.1
0.2
53.5
55.8
22.8
25.3
63.3
53.3
-7.7
-28
0.412
46.7
43.7
18.1
16.1
0.3
47
44
18.4
16.4
57.6
47.6
-10.6
-29.2
0.47
44.7
38.8
19
14.5
0.3
45
39.1
19.3
14.8
56.5
46.5
-11.5
-27.2
0.988
31.4
47.4
13
17.6
0.3
31.7
47.7
13.3
18.9
56.0
46.0
-8.3
-28.1
1.043
32.1
36
11.2
12.3
0.3
32.4
36.3
11.5
12.6
56.0
46.0
-19.7
-33.4
1.141
30.7
38.8
15.1
12.3
0.3
31
39.1
15.4
12.6
56.0
46.0
-16.9
-30.6
AVG.
Limit
(dBuV)
Q.P
Value
AVG.
Value
Margins (dB)
Q.P
Factor
Result (dBuV)
Q.P Value AVG. Value
Freq.
Q.P Value
Meter Reading
(dBuV)
AVG. Value
Notes:
1. The EUT was placed 0.8m above reference ground plane.
2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value
doesn’t need to be measured.
3. The expanded uncertainty of the conducted emission tests is 2.45 dB.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
39 of 39
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
40 of 40
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
41 of 41
EMC Test Report: CE03111004-A
19.1.5 Test Mode 6 (CH 13g@ 54Mbps Bit - Rate)
Relative Humidity: 70 %
Temperature: 24°C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
(MHz)
N
L1
N
L1
(dB)
N
L1
N
L1
0.205
53.7
55.5
22.9
24.9
0.2
53.9
55.7
23.1
25.1
63.4
53.4
-7.7
-28.3
0.295
38.9
41.5
13.5
14.7
0.2
39.1
41.7
13.7
14.9
60.4
50.4
-18.6
-35.4
0.369
46.8
40.8
17
15.1
0.3
47.1
41.1
17.3
15.4
58.5
48.5
-11.4
-31.2
0.408
47.1
48.2
18.7
18
0.3
47.4
48.5
19
18.3
57.7
47.7
-9.2
-28.7
0.443
46
36
17.2
15.8
0.3
46.3
36.3
17.5
16.1
57.0
47.0
-10.7
-29.5
0.559
35.7
32.4
12.3
10.8
0.3
36
32.7
12.6
11.1
56.0
46.0
-20.0
-33.4
Freq.
Q.P Value
Meter Reading
(dBuV)
AVG. Value
Factor
Result (dBuV)
Q.P Value AVG. Value
AVG.
Limit
(dBuV)
Q.P
Value
AVG.
Value
Margins (dB)
Q.P
Notes:
1. The EUT was placed 0.8m above reference ground plane.
2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value
doesn’t need to be measured.
3. The expanded uncertainty of the conducted emission tests is 2.45 dB.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
42 of 42
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
43 of 43
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
44 of 44
EMC Test Report: CE03111004-A
19.2. Photographs of Conducted Powerline Test Configuration
z
The photographs show the configuration that generates the maximum emission.
FRONT VIEW
REAR VIEW
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
45 of 45
EMC Test Report: CE03111004-A
20. Test Result of Radiated Emission
20.1. Test Mode 1 (TX / RX @ 11Mbps Bit – Rate)
Relative Humidity: 70 %
Temperature: 24°C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
(802.11b)
Emission
frequency
CORR'd
Factor
Limit
(10m)
(MHz)
HOR.
VERT.
(dB)
HOR.
VERT.
(dBuV/m)
34.619
35.9
36.1
-11.4
24.5
24.7
30
-5.3
106.481
36.7
37.2
-12.9
23.8
24.3
30
-5.7
163.992
35.4
37.3
-13.5
21.9
23.8
30
-6.2
173.408
38.4
39
-13.8
24.6
25.2
30
-4.8
212.525
39
39.4
-13.3
25.7
26.1
30
-3.9
256.773
40
41.2
-9.5
30.5
31.7
37
-5.3
Meter Reading
(dBuV)
Results
(dBuV/m)
Margins
(dB)
Notes:
1. Measurement Distance: 10m
2. Height of table on which the EUT was placed: 0.8m
3. Height of Receiving Antenna: 1 - 4m
4. Remark “---“ means that the emissions level is too low to be measured.
5. The expanded uncertainty of the radiated emission tests is 3.53 dB.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
46 of 46
EMC Test Report: CE03111004-A
20.1.1 Test Mode 2 (TX / RX @ 54Mbps Bit - Rate)
Relative Humidity: 70 %
Temperature: 24°C
Test Date: Nov. 28, 2003
Power Supply System: AC Power: 230Vac 50Hz
Test Set-up: Table-top Equipment
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
(802.11g)
Emission
frequency
CORR'd
Factor
Limit
(10m)
(MHz)
HOR.
VERT.
(dB)
HOR.
VERT.
(dBuV/m)
47.696
41.1
42.4
-17.7
23.4
24.7
30
-5.3
105.711
37.8
37.6
-13.1
24.7
24.5
30
-5.3
158.964
39.1
38.1
-13.3
25.8
24.8
30
-4.2
190.401
40.3
39.8
-13.9
26.4
25.9
30
-3.6
256.748
36.8
37.6
-9.5
27.3
28.1
37
-8.9
271.636
39.7
40.7
-10.3
29.4
30.4
37
-6.6
Meter Reading
(dBuV)
Results
(dBuV/m)
Margins
(dB)
Notes:
1. Measurement Distance: 10m
2. Height of table on which the EUT was placed: 0.8m
3. Height of Receiving Antenna: 1 - 4m
4. Remark “---“ means that the emissions level is too low to be measured.
5. The expanded uncertainty of the radiated emission tests is 3.53 dB.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
47 of 47
EMC Test Report: CE03111004-A
20.2. Photographs of Radiated Emission Test Configuration
z
The photographs show the configuration that generates the maximum emission.
FRONT VIEW
REAR VIEW
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
48 of 48
EMC Test Report: CE03111004-A
21. Harmonics Test
Basic Standard : EN 61000-3-2:1995/A1/A2:1998/A14:2000
AC Power : 230Vac 50Hz
Temperature : 25 ℃
Test Data : Nov. 28, 2003
Relative Humidity : 50 % RH
Urms = 230.1V Freq = 49.984 Range: 0.25A
Irms = 0.043A Ipk = 0.075A cf = 1.749
P = 6.393W Pap = 9.859VA pf = 0.648
THDi = 43.00% THDu = 0.10% Calss A
Test-Time: 3min (100%)
Test completed Result: PASSED
Order
Freq. (Hz)
Imax (A)
Limit (A)
Order
Freq. (Hz)
Imax (A)
Limit (A)
1
50
0.121
21
1050
0.0002
0.1071
2
100
0.0005
1.08
22
1100
0
0.0836
3
150
0.0133
2.3
23
1150
0.0003
0.0978
4
200
0.0002
0.43
24
1200
0
0.0767
5
250
0.0127
1.14
25
1250
0.0002
0.09
6
300
0.0001
0.3
26
1300
0
0.0708
7
350
0.0024
0.77
27
1350
0.0002
0.0833
8
400
0.0001
0.23
28
1400
0
0.0657
9
450
0.0015
0.4
29
1450
0.0002
0.0766
10
500
0
0.184
30
1500
0
0.0613
11
550
0.0016
0.33
31
1550
0.0001
0.0726
12
600
0
0.1533
32
1600
0
0.0575
13
650
0.0008
0.21
33
1650
0.0001
0.0682
14
700
0
0.1314
34
1700
0
0.0541
15
750
0.0005
0.15
35
1750
0.0001
0.0643
16
800
0
0.115
36
1800
0
0.0511
17
850
0.0005
0.1324
37
1850
0.0001
0.0608
18
900
0
0.1022
38
1900
0
0.0484
19
950
0.0003
0.1184
39
1950
0.0001
0.0577
20
1000
0
0.092
40
2000
0
0.046
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
49 of 49
EMC Test Report: CE03111004-A
22. Voltage Fluctuations Test
z
Basic Standard : EN 61000-3-3:1995/A1:1998
z
FINAL TEST RESULT : PASS
z
Temperature
: 25 ℃
z
Test Data : Nov. 28, 2003
z
Relative Humidity
: 50 % RH
Pst
Plt
Dc ( % )
Dmax ( % )
Dt ( % )
Reading
0.070
0.070
0.00
0.00
0.00
Limit
0.65
1.0
3.0
4.0
3.0
22.1. TEST EQUIPMENT SETTINGS
z
Line Voltage : 230 V
z
Test Duration : 00:10:00 minutes
z
Line Frequency : 50 Hz
z
Measurement Delay : 10.0 seconds
z
Pst Integration Periods : 1
z
Pst Integration Time : 10 minutes
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
50 of 50
EMC Test Report: CE03111004-A
22.2. Photographs of Harmonics test, Voltage Fluctuation and Flicker test
Harmonics test
Flicker test
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
51 of 51
EMC Test Report: CE03111004-A
23. Electrostatic Discharge Immunity Test (ESD)
Final Test Result
:
PASS
Pass performance Criteria
:
TT/TR
Required performance criteria :
TT/TR
Basic Standard
:
EN 61000-4-2:1995/A1:1998/A2:2000
Product Standard
EN 301 489-17
Level
:
3 for air discharge,
2 for contact discharge
Test Voltage
:
±2 / ±4 / ±8 KV for air discharge,
±2 / ±4 KV for contact discharge
Temperature
:
25 °C
Relative Humidity
:
60%
Test Date
:
Nov. 28, 2003
Observation
:
Normal
23.1. Test Severity Levels
Contact Discharge
Air Discharge
Level
Test Voltage (KV) of
Contact discharge
Level
Test Voltage (KV) of
Air Discharge
1
±2
1
±2
2
±4
2
±4
3
±6
3
±8
4
±8
4
±15
X
Specified
X
Specified
Remark: “X” is an open level.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
52 of 52
EMC Test Report: CE03111004-A
23.2. Test Result of Air Discharge/ Contact Discharge
Energy-Storage Capacitor: 150 pF
Discharge Resistor : 330 Ω
Contact Discharge Times: 10 times/each condition
Air Discharge Times : 10 times/each condition
\Discharge Mode
Contact Discharge
Air Discharge
\ESD Voltage
2 KV 4 KV KV KV 2 KV 4 KV 8 KV KV
\Points \Result \Polarity
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
VCP
N
N
N
N
---
---
---
---
---
---
---
---
---
---
---
---
HCP
N
N
N
N
---
---
---
---
---
---
---
---
---
---
---
---
P1~P7
---
---
---
---
---
---
---
---
N
N
N
N
N
N
---
---
P8
N
N
N
N
---
---
---
---
---
---
---
---
---
---
---
---
Note: ”N” means the EUT function was correct during the test.
” --- “means the test could not be carrier out.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
53 of 53
EMC Test Report: CE03111004-A
23.3. Photographs of Electrostatic Discharge Immunity Test
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
54 of 54
EMC Test Report: CE03111004-A
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
55 of 55
EMC Test Report: CE03111004-A
24. Radio Frequency Electromagnetic Field Immunity Test (RS)
Final Test Result
:
PASS
Pass performance Criteria
:
CT/CR
Required performance criteria :
CT/CR
Basic Standard
:
EN 61000-4-3:1996/A1:1998/A2:2000
Product Standard
EN 301 489-17
Level
:
2
Frequency Range
:
80-1000 MHz; 1400-2000 MHz
Field Strength
:
3 V/m (Modulated 80% AM)
Temperature
:
26 °C
Relative Humidity
:
65 %
Test Date
:
Nov. 28, 2003
Observation
:
Normal
24.1. Test Severity Levels
Frequency Range (MHz)
Test Axis
Polarization of Device
Test Result
80~1000
1400~2000
x- axis
Vertical
N
80~1000
1400~2000
y- axis
Vertical
N
80~1000
1400~2000
z- axis
Vertical
N
Note: “ N ” means the EUT function was correct during the test.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
56 of 56
EMC Test Report: CE03111004-A
24.2. Photographs of Radio Frequency Electromagnetic Field Immunity Test
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
57 of 57
EMC Test Report: CE03111004-A
25. Electrical Fast Transient/Burst Immunity Test (EFT/BURST)
Final Test Result
: PASS
Pass performance Criteria
: CT/CR
Required performance criteria : TT/TR
Basic Standard
: EN61000-4-4:1995/A1:200
Product Standard
EN 301 489-17
Level
:
2
Test Voltage
:
on Power Supply -- ±1.0 KV
on I/O signal, data and control line -- ±0.5 KV
Temperature
:
25 °C
Relative Humidity
:
60 %
Test Date
:
Nov. 28, 2003
Observation
:
Normal
25.1. Test Severity Levels
0.5 kV
1.0 kV
\Voltage\Polarity
\Test Point\Mode\Result
+
-
+
-
L
N
N
N
N
N
N
N
N
N
Power Line
L-N
N
N
N
N
LAN Line
N
N
---
---
Note: “N” means the EUT function was correct during the test.
“---“means the test could not be carrier out.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
58 of 58
EMC Test Report: CE03111004-A
25.2. Photographs of Electrical Fast Transient/BURST Immunity Test
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
59 of 59
EMC Test Report: CE03111004-A
26. Surge Immunity Test
FINAL TEST RESULT
:
PASS
Pass performance Criteria
:
CT/CR
Required performance criteria :
TT/TR
Basic Standard
:
EN 61000-4-5 :1995/A1:2000
Product Standard
EN 301 489-17
Surge wave form (Tr/Th)
:
1, 2/50(8/20)µs
Level
:
on Signal ports And Telecommunication – N/A
on Input AC Power Port -- 2
Test Voltage
:
on Signal ports And Telecommunication – N/A
on Input AC Power Port -- ±1.0 KV
Temperature
:
25 °C
Relative Humidity
:
60 %
Test Date
:
Nov. 28, 2003
Remark
:
“ N “ means the EUT function was correct during the test.
Angle
; 0° ; 90° ; 180° ; 270° ; 360°
Voltage ( KV ): 0.5 kV
Test Location: L-N
Test Result: PASS
26.1. TEST LEVEL
\Phase \Voltage \Mode \Polarity \Result
0°
90°
180°
270°
360°
+
N
N
N
N
N
0.5 kV
L-N
-
N
N
N
N
N
Note: “N” means the EUT function was correct during the test.
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
60 of 60
EMC Test Report: CE03111004-A
26.2. Photographs of Surge Immunity Test
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
61 of 61
EMC Test Report: CE03111004-A
27. Conducted Disturbances Induced by
Radio-Frequency Field Immunity Test (CS)
Final Test Result
:
PASS
Pass performance Criteria
:
CT/CR
Required performance criteria :
CT/CR
Basic Standard
:
EN 61000-4-6 :1996/A1:2000
Product Standard
EN 301 489-17
Level
:
2
Test Voltage
3 V rms ( Modulated, 1KHz, 80%, AM )
Frequency Range
0.15 MHz to 80 MHz
Dwell time
2.9 seconds
Frequency step size
1 %
Coupling mode
CDN-M2 for AC power ports, Clamp for Signal Ports
Temperature
:
25 °C
Relative Humidity
:
50 %
Test Date
:
Nov. 28, 2003
Observation
:
Normal
27.1. TEST LEVEL
Frequency Range (MHz)
Tested Line
Test Result
0.15~80
Power Line
N
0.15~80
LAN Line
N
Note: “N” means the EUT function was correct during the test.
27.2. OPERATING CONDITION
Full system
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
62 of 62
EMC Test Report: CE03111004-A
27.3. Photographs of CS Tests
Power Line
LAN Line
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
63 of 63
EMC Test Report: CE03111004-A
28. Voltage Dips and Voltage Interruptions Immunity Tests
Final Test Result
:
PASS
Pass performance Criteria
TT/TR for voltage interruption, CT/CR and TT/TR for voltage dips
Required performance criteria
TT/TR for voltage interruption, TT/TR for voltage dips
Basic Standard
:
EN 61000-4-11:1994/A4:2000
Product Standard
EN 301 489-17
Temperature
:
25 °C
Relative Humidity
:
50 %
Test Date
:
Nov. 28, 2003
28.1. TEST LEVEL
TEST RECORD OF VOLTAGE INTERRUPTION/ DIPS
Test mod
Voltage
dips
Durations
(period / ms)
Interval(s)
Times
Phase
Result
Voltage interruptions
100%
5000
10
12
0°/180°
B
60%
100
10
12
0°/180°
N
Voltage dips in %UT
30%
10
10
12
0°/180°
N
Note: “N” means the EUT function was correct during test.
“B” means the EUT’s function was fail during the test, the EUT operate as
intended without operator intervention.
EMS Test Engineer: Kevin Lee
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
64 of 64
EMC Test Report: CE03111004-A
28.2. Photographs of Voltage Dips and Voltage Interruptions Immunity Tests
Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100
Issued date: Dec. 16, 2003
65 of 65
EMC Test Report: CE03111004-A
29. List of Measuring Equipment Used
(EMS)
Test Equipment
Calibration Date
Recommended
Recal. Date
EMC Emission Tester EMC-Partner Harnmonics-1000
Sep.06,2003
Sep.05,2004
EMC Immunity tester\EMC-Partener\TRANSIENT-1000
Oct.17,2003
Oct.16,2004
Metering Unit & Probe\EMCO\7122
Oct.30,2003
Oct.29,2004
SMGL Generator\Agilent\83640B
Jun.23,2003
Jun.22,2004
Amplifier\ar\50S1G4AM1
Jun.23,2003
Jun,22,2004
Test System : FRANKONIA EMV-Mess-System GmbH\CIT-10
Feb.18,2003
Feb.17,2004
CDN : FRANKONIA EMV-Mess-System GmbH\CDN M2+M3
Jul.17,2003
Jul.16,2004
EM-Clamp : Schaffner\KEMZ801
Feb.09,2003
Feb.08,2004