Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 1 of 1 EMC Test Report: CE03111004-A CE EMC TEST REPORT according to EN 301 489-1 V1.4.1 (2002-08) and EN 301 489-17 V1.2.1 (2002-08) Applicant TRENDware International, Inc. Address 3135 Kashiwa Street, Torrance, CA90505 U.S.A. Equipment Cable/DSL 802.11g 54Mbps Wireless Router Model No. TEW-431BRP Trade Name TRENDware Power Supply Type AC Adaptor: Model: MW48-1201000U, I/P: 230Vac/50Hz; O/P: 12Vdc, 800mA ‚ The test result refers exclusively to the test presented test model / sample. ‚ Without written approval of Exclusive Certification Corp. the test report shall not be reproduced except in full. ‚ This test report is only applicable to European Community.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 2 of 2 EMC Test Report: CE03111004-A Contents CERTIFICATE OF COMPLIANCE.......................................................................................................................4 1. Definition......................................................................................................................................................5 2. Test Distance...............................................................................................................................................6 2.1. Summary of Test Results ...........................................................................................................6 3. Test of Conducted Powerline.......................................................................................................................7 3.1. Test Procedures .........................................................................................................................7 3.2. Typical Test Setup Layout of Conducted Powerline...................................................................8 3.3. Conducted Emission Requirement ............................................................................................8 4. Test of Radiated Emission...........................................................................................................................9 4.1. Test Procedures .........................................................................................................................9 4.2. Typical Test Setup Layout of Radiated Emission.....................................................................10 4.3. Radiated Emission Requirement .............................................................................................10 5. Harmonics Test..........................................................................................................................................11 5.1. STANDARD..............................................................................................................................11 5.2. Test Procedure.........................................................................................................................11 6. Voltage Fluctuations Test...........................................................................................................................12 6.1. STANDARD..............................................................................................................................12 6.2. Test Procedure.........................................................................................................................12 7. Test setup (ESD) .......................................................................................................................................13 7.1. Test Setup for Tests Performed in Laboratory..........................................................................13 7.2. Test Procedure.........................................................................................................................14 8. Test Procedure (RS)..................................................................................................................................15 9. Test on Power Line (EFT)..........................................................................................................................16 9.1. Test on Communication Lines..................................................................................................16 9.2. Test Procedure.........................................................................................................................16 10. Test Procedure (Surge).....................................................................................................................17 11. Test Procedure (CS) .........................................................................................................................18 12. Testing Requirement and Procedure (DIP).......................................................................................19 12.1. Test Conditions.........................................................................................................................19 12.2. Operating Condition .................................................................................................................19 13. Notice for Class A Product................................................................................................................20 14. Declaration of Conformity and the CE Mark.....................................................................................20 15. Feature of Equipment under Test .....................................................................................................21 15.1. History of this test report ..........................................................................................................21 16. Test Configuration of Equipment under Test.....................................................................................22 16.1. Test Mode.................................................................................................................................22 16.2. Description of Test System.......................................................................................................22 17. Test Software ....................................................................................................................................23 18. General Information of Test ..............................................................................................................24 18.1. Description of Major Test Instruments......................................................................................25 19. Test Result of AC Powerline Conducted Emission ...........................................................................26 19.1. Test Mode 1 (CH 01b @ 11Mbps Bit-Rate)..............................................................................26 19.2. Photographs of Conducted Powerline Test Configuration .......................................................44 20. Test Result of Radiated Emission.....................................................................................................45 20.1. Test Mode 1 (TX / RX @ 11Mbps Bit – Rate) ..........................................................................45

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 3 of 3 EMC Test Report: CE03111004-A 20.2. Photographs of Radiated Emission Test Configuration ...........................................................47 21. Harmonics Test .................................................................................................................................48 22. Voltage Fluctuations Test..................................................................................................................49 22.1. TEST EQUIPMENT SETTINGS...............................................................................................49 22.2. Photographs of Harmonics test, Voltage Fluctuation and Flicker test .....................................50 23. Electrostatic Discharge Immunity Test (ESD)...................................................................................51 23.1. Test Severity Levels .................................................................................................................51 23.2. Test Result of Air Discharge/ Contact Discharge .....................................................................52 23.3. Photographs of Electrostatic Discharge Immunity Test ...........................................................53 24. Radio Frequency Electromagnetic Field Immunity Test (RS)...........................................................55 24.1. Test Severity Levels .................................................................................................................55 24.2. Photographs of Radio Frequency Electromagnetic Field Immunity Test.................................56 25. Electrical Fast Transient/Burst Immunity Test (EFT/BURST) ...........................................................57 25.1. Test Severity Levels .................................................................................................................57 25.2. Photographs of Electrical Fast Transient/BURST Immunity Test.............................................58 26. Surge Immunity Test .........................................................................................................................59 26.1. TEST LEVEL............................................................................................................................59 26.2. Photographs of Surge Immunity Test.......................................................................................60 27. Conducted Disturbances Induced by Radio-Frequency Field Immunity Test (CS) ................61 27.1. TEST LEVEL............................................................................................................................61 27.2. OPERATING CONDITION.......................................................................................................61 27.3. Photographs of CS Tests .........................................................................................................62 28. Voltage Dips and Voltage Interruptions Immunity Tests....................................................................63 28.1. TEST LEVEL............................................................................................................................63 28.2. Photographs of Voltage Dips and Voltage Interruptions Immunity Tests .................................64 29. List of Measuring Equipment Used...................................................................................................65 Appendix A. Photographs of EUT……………………………………..…..………… ……….….……..A1 ~ A4

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 4 of 4 EMC Test Report: CE03111004-A CERTIFICATE OF COMPLIANCE according to EN 301 489-1 V1.4.1 (2002-08) and EN 301 489-17 V1.2.1 (2002-08) Applicant TRENDware International, Inc. Address 3135 Kashiwa Street, Torrance, CA90505 U.S.A. Equipment Cable/DSL 802.11g 54Mbps Wireless Router Model No. TEW-431BRP I HEREBY CERTIFY THAT : The measurements shown in this test report were made in accordance with the procedures given in EUROPEAN COUNCIL DIRECTIVE 99/5/EC. The equipment was passed the test performed according to EN 301 489-1 V1.4.1 (2002-08) and EN 301 489-17 V1.2.1 (2002-08). The test was carried out on Nov. 28, 2003 at Electronics Testing Center, Taiwan.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 5 of 5 EMC Test Report: CE03111004-A 1. Definition Unintentional radiator: A device that intentionally generates and radio frequency energy for use within the device, or that sends radio frequency signals by conduction to associated equipment via connecting wiring, but which is not intended to emit RF energy by radiation or induction. Class A Digital Device: A digital device Which is marketed for use in commercial or business environment; exclusive of a device which is market for use by the general public, or which is intended to be used in the home. Class B Digital Device: A digital device which is marketed for use in a residential environment notwithstanding use in a commercial, business of industrial environment. Example of such devices that are marketed for the general public. Note: A manufacturer may also qualify a device intended to be marketed in a commercial, business, or industrial environment as a Class B digital device, and in fact is encouraged to do so, In the event that a particular type of device has been found to repeatedly cause harmful interference to radio communications, the Commission may classify such a digital device as a Class B Digital Device, Regardless of its intended use. Intentional radiator: A device that intentionally generates and emits radio frequency energy by radiation or induction.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 6 of 6 EMC Test Report: CE03111004-A 2. Test Distance a. The test distance of radiated emission test from antenna to EUT is 10 M. b. The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 M. 2.1. Summary of Test Results 19.1.1 Emission Tests Measurement Reference Clause(s) Test Reference standard Radiated emission 8.2 PASSED EN 55022/A1:2000 class B Conducted emission 8.3/8.4 PASSED EN 55022/A1:2000 class B Harmonic current emissions 8.5 N/A EN 61000-3-2:2000 Voltage fluctuations and flicker 8.6 PASSED EN 61000-3-3:1995 19.1.2 Immunity Tests Measurement Reference Clause(s) Test Reference standard Electrostatic discharge 9.3 PASSED EN 61000-4-2:1995/A1:1998 RF electro-magnetic Field (80-1000 MHz, 1400-2000 MHz.) 9.2 PASSED EN 61000-4-3:1996/A1:1998 Fast transients common mode 9.4 PASSED EN 61000-4-4:1995 Surge 9.8 PASSED EN 61000-4-5:1995 Radio frequency, common mode 9.5 PASSED EN 61000-4-6:1996 Voltage dips and interrupts 9.7 PASSED EN 61000-4-11:1994

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 7 of 7 EMC Test Report: CE03111004-A 3. Test of Conducted Powerline Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz and return leads of the EUT according to the methods defined in European Standard EN 301 489-17. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section 2.2. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions. 3.1. Test Procedures a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded conducting surface. b. Connect EUT to the power mains through a line impedance stabilization network (LISN). c. All the support units are connect to the other LISN. d. The LISN provides 50 ohm coupling impedance for the measuring instrument. e. The CISPR states that a 50 ohm , 50 microhenry LISN should be used. f. Both sides of AC line were checked for maximum conducted interference. g. The frequency range from 150 kHz to 30 MHz was searched h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 8 of 8 EMC Test Report: CE03111004-A 3.2. Typical Test Setup Layout of Conducted Powerline 3.3. Conducted Emission Requirement The equipment under test EUT)shall meet the limits in table 1and 3 or 2 and 4,as applicable, including the average limit and the quasi-peak limit when using,repectively, an average detector receiver and quasi-peak detector receiver and measured in accordance with the methods described in clause 9. Either the voltage limits or the current limits in table 3 or 4, as applicable, shall be met except for the measurement method of C.1.3 where both limits shall be met. If the average limit is met when using a qusai-peak decetor reciver, the EUT shall be deemeed to meet both limits and measurement with the average detector receiver is unnecessary. If the reading of the measuring receiver shows fluctuations close to the limit, the reading shall be observed for at least 15 s at each measurement frequency, the higher reading shall be recorded with the exception of any brief isolated hith reading which shall be ignored. Limits (dB µ V) Frequency range (MHz) Quasi Peak Average 0.15 to0.50 66 to 56* 56 to 46* 0.50 to5 56 46 5. to 30. 60 50 NOTE 1-The lower limits shall apply at the transition frequencies. NOTE 2-The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHZ to 0.50MHZ. 10cm 80cm EUT 80cm 40cm LISN 80cm 40cm LISN

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 9 of 9 EMC Test Report: CE03111004-A 4. Test of Radiated Emission Radiated emissions from 30 MHz to 1000 MHz were measured with a bandwidth of 120 kHz according to the methods defines in European Standard EN 301 489-17. The EUT was placed on a nonmetallic stand in the open-field site, 0.8 meter above the ground plane, as shown in section 3.2. The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions. 4.1. Test Procedures a. The EUT was placed on a rotatable table top 0.8 meter above ground. b. The EUT was set 10 meters from the interference receiving antenna which was mounted on the top of a variable height antenna tower. c. The table was rotated 360 degrees to determine the position of the highest radiation. d. The antenna is a half wave dipole and its height is varied between one meter and four meters above ground to find the maximum value of the field strength both horizontal polarization and vertical polarization of the antenna are set to make the measurement. e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the maximum reading. f. Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold Mode. g. If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB margin will be repeated one by one using the quasi-peak method and reported.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 10 of 10 EMC Test Report: CE03111004-A 4.2. Typical Test Setup Layout of Radiated Emission 4.3. Radiated Emission Requirement The EUT shall meet limits of tables as below when measured at the measuring distance R in accordance with the methods described in clause 10. If the reading on the measuring receiver shows fluctuations close to the limit, the reading shall be observed for at least 15 s at each isolated high reading, which shall be ignored. Limit for radiated disturbance of class B ITE at a measuring distance of 10 m Frequency (MHz) Quasi-peak limits dB (uV/m) 30 to 230 30 230 to 1000 37 Note 1- The lower limit shall apply at the transition frequency. 2- Additional provisions may be required for cases where interference occurs. Turn Table 0.8M Equipment under Test Ground Plane Receiver * Test distance Antenna

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 11 of 11 EMC Test Report: CE03111004-A 5. Harmonics Test 5.1. STANDARD z Product Standard : EN 61000-3-2:2000 5.2. Test Procedure As specified on clause 7 and figure Z1 of EN 61000-3-2:2000, the limits are not specified for equipment with a rated power of 75W or less. The EUT meets the above condition, so it conforms to EN 61000-3-2.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 12 of 12 EMC Test Report: CE03111004-A 6. Voltage Fluctuations Test 6.1. STANDARD z Product Standard : EN 61000-3-3:1995/A1:2001 6.2. Test Procedure The equipment shall be tested under the conditions of Clause 5. The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of ±8% is achieved during the whole assessment procedure.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 13 of 13 EMC Test Report: CE03111004-A 7. Test setup (ESD) HCP TABLE SIZE 1.6LX0.8WX0.5H m VCP: 0.5x0.5 m 470K ohm GRP 470K ohm 470K ohm 470K ohm 10cm 10cm EUT 1.6mx0.8m The test setup consists of the test generator, EUT and auxiliary instrumentation necessary to perform DIRECT and INDIRECT application of discharges to the EUT as applicable, in the follow manner : a. CONTACT DISCHARGE to the conductive surfaces and to coupling plane; b. AIR DISCHARGE at insulating surfaces. The preferred test method is that of type tests performed in laboratories and the only accepted method of demonstrating conformance with this standard. The EUT was arranged as closely as possible to arrangement in final installed conditions. 7.1. Test Setup for Tests Performed in Laboratory A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper or aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at least 0.65 mm thickness. In the ELECTRONICS TESTING CENTER., we provided 1 mm thickness aluminum ground reference plane or 1 mm thickness stainless steel ground reference plane. The minimum size of the ground reference plane is 1 m x 1 m, the exact size depending on the dimensions of the EUT. It was connected to the protective grounding system. The EUT was arranged and connected according to its functional requirements. A distance of 1m minimum was provided between the EUT and the wall of the lab. and any other metallic structure. In cases where this length exceeds the length necessary to apply the discharges to the selected points, the excess length shall, where possible, be placed non-inductively off the ground reference plane and shall not come closer than 0.2m to other conductive parts in the test setup. Where the EUT is installed on a metal table, the table was connected to the reference plane via a cable with a 470k ohm resister located at each end, to prevent a build-up of charge. The test setup was consist a wooden table, 0.8m high, standing on the ground reference plane. A HCP, 1.6 m x 0.8 m, was placed on the table. The EUT and cables was isolated from the HCP by an insulating support 0.5 mm thick. The VCP size, 0.5 m x 0.5 m.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 14 of 14 EMC Test Report: CE03111004-A 7.2. Test Procedure a. In the case of air discharge testing the climatic conditions shall be within the following ranges: - ambient temperature: 15 to 35 ; ℃ ℃ - relative humidity : 30% to 60%; - atmospheric pressure : 68 KPa (680 mbar) to 106 KPa (1060 mbar). b. Test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. c. The test voltage shall be increased from the minimum to the selected test severity level, in order to determine any threshold of failure. The final severity level should not exceed the product specification value in order to avoid damage to the equipment. d. The test shall be performed with both air discharge and contact discharge. On preselected points at least 10 single discharges (in the most sensitive polarity) shall be applied on air discharge. On preselected points at least 25 single discharges (in the most sensitive polarity) shall be applied on contact discharge. e. For the time interval between successive single discharges an initial value of one second is recommended. Longer intervals may be necessary to determine whether a system failure has occurred. f. In the case of contact discharges, the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. g. In the case of painted surface covering a conducting substrate, the following procedure shall be adopted : — If the coating is not declared to be an insulating coating by the equipment manufacturer, then the pointed tip of the generator shall penetrate the coating so as to make contact with the conducting substrate. — Coating declared as insulating by the manufacturer shall only be submitted to the air discharge. — The contact discharge test shall not be applied to such surfaces. h. In the case of air discharges, the round discharge tip of the discharge electrode shall be approached as fast as possible (without causing mechanical damage) to touch the EUT . After each discharge, the ESD generator (discharge electrode) shall be removed from the EUT. The generator is then retriggered for a new single discharge. This procedure shall be repeated until the discharges are completed. In the case of an air discharge test, the discharge switch, which is used for contact discharge, shall be closed.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 15 of 15 EMC Test Report: CE03111004-A 8. Test Procedure (RS) a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment is then connected to power and signal leads according to pertinent installation instructions. b. The antenna which is enabling the complete frequency range of 80-1000MHz; 1400-2000 MHz is placed 3m away from the equipment. The required field strength is determined by placing the field strength meter(s) on top of or directly alongside the equipment under test and monitoring the field strength meter via a remote field strength indicator outside the enclosure while adjusting the continuous-wave to the applicable antennae. c. The test is normally performed with the antenna facing the most sensitive side of the EUT. The polarization of the field generated by the biconical antenna necessitates testing each position twice, once with the antenna positioned vertically and again with the antenna positioned horizontally. The circular polarization of the field from the log-spiral antenna makes a change of position of the antenna unnecessary. d. At each of the above conditions, the frequency range is swept 80-1000 MHz; 1400-2000 MHz, pausing to adjust the R.F. signal level or to switch oscillators and antenna. The rate of sweep is in the order of 1.5*10-3 decades/s. The sensitive frequencies or frequencies of dominant interest may be discretely analyzed.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 16 of 16 EMC Test Report: CE03111004-A 9. Test on Power Line (EFT) a. The EFT/B-generator was located on the GRP.. The length from the EFT/B-generator to the EUT as not exceed 1 m. b. The EFT/B-generator provides the ability to apply the test voltage in a non-symmetrical condition to the power supply input terminals of the EUT.. 9.1. Test on Communication Lines a. The coupling clamp is composed of a clamp unit for housing the cable (length more than 3 m), and was placed on the GRP. b. The coupling clamp provides the ability of coupling the fast transient/bursts to the cable under test. 9.2. Test Procedure a. In order to minimize the effect of environmental parameters on test results, the climatic conditions when test is carrying out shall comply with the following requirements: — ambient temperature: 15 to 35 ; ℃ ℃ — relative humidity : 45% to 75%; — atmospheric pressure : 68 Kpa (680 mbar) to 106 Kpa (1060 mbar). b. In order to minimize the effect of environmental parameters on test results, the electromagnetic environment of the laboratory shall not influence the test results. c. The variety and diversity of equipment and systems to be tested make it difficult to establish general criteria for the evaluation of the effects of fast transients/bursts on equipment and systems. d. The test results may be classified on the basic of the operating conditions and the functional specification of the equipment under test, according to the following performance criteria : — Normal performance within the specification limits. — Temporary degradation or loss of function or performance which is self-recoverable. — Temporary degradation or loss of function or performance which requires operator intervention or system reset. — Degradation or loss of function which is not recoverable due to damage of equipment (components).

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 17 of 17 EMC Test Report: CE03111004-A 10. Test Procedure (Surge) a. Climatic conditions The climatic conditions shall comply with the following requirements : — ambient temperature : 15 to 35 ℃ ℃ — relative humidity : 10 % to 75 % — atmospheric pressure : 86 kPa to 106 kPa ( 860 mbar to 1060 mbar ) b. Electromagnetic conditions the electromagnetic environment of the laboratory shall not influence the test results. c. The test shall be performed according the test plan that shall specify the test set-up with — generator and other equipment utilized; — test level ( voltage/current ); — generator source impedance; — internal or external generator trigger; — number of tests : at least five positive and five negative at the selected points; — repetition rate : maximum 1/min. — inputs and outputs to be tested; — representative operating conditions of the EUT; — sequence of application of the surge to the circuit; — phase angle in the case of a.c. power supply; — actual installation conditions, for example : AC : neutral earthed, DC : ( + ) or ( - ) earthed to simulated the actual earthing conditions. d. If not otherwise specified the surges have to be applied synchronized to the voltage phase at the zero-crossing and the peak value of the a.c. voltage wave ( positive and negative ). e. The surges have to be applied line to line and line(s) and earth. When testing line to earth, the test voltage has to be applied successively between each of the lines and earth, if there is no other specification. f. The test procedure shall also consider the non-linear current-voltage characteristics of the equipment under test. Therefore the test voltage has to be increased by steps up to the test level specified in the product standard or test plan. g. All lower levels including the selected test level shall be satisfied. For testing the secondary protection, the output voltage of the generator shall be increased up to the worstcase voltage breakdown level ( let-through level ) of the primary protection. h. If the actual operating signal sources are not available, the may be simulated. Under no circumstances may the test level exceed the product specification. The test shall be carried out according the a test plan. i. To find all critical points of the duty cycle of the equipment, a sufficient number of positive and negative test pulses shall be applied. For acceptance test a previously unstressed equipment shall be used to the protection devices shall be replaced.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 18 of 18 EMC Test Report: CE03111004-A 11. Test Procedure (CS) a. The EUT shall be operated within its intended climatic conditions. The temperature and relative humidity should be recorded. b. This test method test can be performed without using a sell shielded enclosure. This is because the disturbance levels applied and the geometry of the setups are not likely to radiated a high amount of energy, especially at the lower frequencies. If under certain circumstances the radiated energy is too high, a shielded enclosure has to be used. c. The test shall be performed with the test generator connected to each of the coupling and decoupling devices in turn while the other non-excited RF-input ports of the coupling devices are terminated by a 50 ohm load resistor. d. The frequency range is swept from 150 KHz to 230 MHz, using the signal levels established during the setting process, and with the disturbance signal 80% amplitude modulated with a 1KHz sinewave, pausing to adjust the RF-signal level or to switch coupling devices as necessary. The rate of sweep shall no exceed 1.5 x 10-3 decades/s. Where the frequency is swept incrementally, the step size shall no exceed 1% of the start and thereafter 1% of the preceding frequency value. e. The dwell time at each frequency shall not be less than the time necessary for the EUT to be exercised, and able to respond. Sensitive frequencies e.g. clock frequency(ies) and harmonics or frequencies of dominant interest shall be analyzed separately. f. An alternative test procedure may be adopted, wherein the frequency range is swept incrementally, with a step size not exceeding 4% of the start ad thereafter 4% of the preceding frequency value. The test level should be at least twice the value of the specified test level. g. In cases of dispute, the test procedure using a step size not exceeding 1% of the start and thereafter 1% of preceding frequency value shall take precedence. h. Attempts should be made to fully exercise the EUT during testing, and to fully interrogate all exercise modes selected for susceptibility. i. The use of special exercising programs is recommended. j. Testing shall be performed according to a Test Plan, which shall be included in the test report. k. It may be necessary to carry out some investigatory testing in order to establish some aspects of the test plan.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 19 of 19 EMC Test Report: CE03111004-A 12. Testing Requirement and Procedure (DIP) The test was based on IEC 61000-4-11 (1994) 12.1. Test Conditions 1. Source voltage and frequency : 230V / 50Hz, Single phase. 2. Test of interval : 10 sec. 3. Level and duration : Sequency of 3 dips/interrupts. 4. Voltage rise (and fall) time : 1 ∼ 5 µs. 5. Test severity : Voltage dip and Interrupt reduction (%) Test Duration (ms) 30 500 60 100 100 10 100 80 100 5000 12.2. Operating Condition Full system

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 20 of 20 EMC Test Report: CE03111004-A 13. Notice for Class A Product This Notice is for class A product only. If the Equipment under Test is a class B product, this notice should be disregarded. Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits. Such equipment should not be restricted in its sale but the following warning shall be included in the instructions for use: Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 14. Declaration of Conformity and the CE Mark There are three possible procedures pertaining to the declaration of conformity: 14.1. Conformity Testing and Declaration of Conformity by the Manufacturer or His Authorized Representative Established within the Community or by an Importer. - Article 10 (1) of the EMC Directive, - § 3 (1) no. 2a of the EMC Act. 14.2. Declaration of Conformity Issued by the Manufacturer or His Authorized Representative Established within the Community or by an Importer Following Testing of the Product and Issued of an EC certificate of conformity by a competent body. - Article 10 (2) of the EMC Directive, - § 3 (1) no. 2b of the EMC Act. 14.3. Declaration of Conformity Issued by the Manufacturer or His Authorized Representative Established within the Community or by an Importer Following Testing and Certification of the Product by a Notified Body. - Article 10 (5) of the EMC Directive, - § 3 (1) no. 2b of the EMC Act (radio transmitting installations). 14.4. Specimen For The CE Marking Of Electrical / Electronical Equipment The components of the CE marking shall have substantially the same vertical dimension, which may not be less than 5 mm.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 21 of 21 EMC Test Report: CE03111004-A 15. Feature of Equipment under Test The Wireless Router incorporates many advanced features, carefully designed to provide sophisticated functions while being easy to use. 15.1. History of this test report The Model No. TEW-431BRP (Report No:CE03111004-A) is the same and it only differs from the outside cosmetic. The functions and specifications are the same.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 22 of 22 EMC Test Report: CE03111004-A 16. Test Configuration of Equipment under Test 16.1. Test Mode z The following test mode was performed for conduction test: z Frequency range investigated: conduction 150 KHz to 30 MHz, radiation 30 MHz to 1000MHz. 16.2. Description of Test System For Conducted Emission Test and Radiated Emission Test Product Manufacturer Model No. Serial No. I/O Cable Wireless Broadband Router TRENDware TEW-431BRP N/A Non-shielded, 1.2m Non-shielded, 2.5m Printer EPSON Stylus photo 700 N/A shielded, 1.2m Notebook PC Comoaq Presario 2800 N/A Non-shielded, 2.5m AC Power Cord Remark “*” means equipment under test.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 23 of 23 EMC Test Report: CE03111004-A 17. Test Software During testing, “Ping.exe” under WIN 2000 was executed to link with the remote workstation to receive and transmit data by UTP cable.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 24 of 24 EMC Test Report: CE03111004-A 18. General Information of Test Test Site : ELECTRONICS TESTING CENTER, Taiwan No. 34, Lin 5, Ding Fu Tdun, Linkou Hsiang, Taipei, Taiwan, R.O.C. Test Voltage : 230V/ 50Hz Test in Compliance with : EMI Test (conduction and radiation) : EN 301 489-1 V.1.4.1 (2002-08) EN 301 489-17 V.1.2.1 (2002-08) Harmonics Test : European Standard EN 61000-3-2. Voltage Fluctuations Test : European Standard EN 61000-3-3. EMS Test : European Standard EN 301 489-1 V.1.4.1 (2002-08). European Standard EN 301 489-17 V.1.2.1 (2002-08). ESD: EN 61000-4-2, RS: EN 61000-4-3, EFT: EN 61000-4-4, SURGE: EN 61000-4-5, CS: EN 61000-4-6, DIPS: EN 61000-4-11 Frequency Range Investigated : Radiated emission test: from 30 MHz to 1,000 MHz Radio frequency electromagnetic field immunity test: 80-1000 MHz, 1400-2000 MHz Test Distance : The test distance of radiated emission test from antenna to EUT is 10 M The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 M.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 25 of 25 EMC Test Report: CE03111004-A 18.1. Description of Major Test Instruments (For Conducted) Test Equipment Calibration Date Recommended Recal. Date Shielded Room\ Riken\--- N.C.R. N.C.R. EMI test receiver\R&S\ESCS30 Aug. 10, 2003 Aug. 09, 2004 L.I.S.N.\EMCO\ESH2-Z5 Sep. 22, 2003 Sep. 21, 2004 Monitor\IBM \E54 N.C.R. N.C.R. Printer\HP\LaserJet 1000 N.C.R. N.C.R. Computer\Acer\Veriton 7500g N.C.R. N.C.R. (For Radiation) Test Equipment Calibration Date Recommended Recal. Date Amplifier Receiver\HP\8447D Feb. 20, 2003 Feb. 19, 2004 Bilog Antenna\Chase\CBL6111C Oct. 29, 2003 Oct. 28, 2004 Pre -selector\HP\85685A Jan. 02, 2003 Jan. 01, 2004 Spectrum Analyzer\HP\8568B Jan. 02, 2003 Jan. 01, 2004 Quasi-Peak Adaptor\HP\85650A Jan. 02, 2003 Jan. 01, 2004

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 26 of 26 EMC Test Report: CE03111004-A 19. Test Result of AC Powerline Conducted Emission 19.1. Test Mode 1 (CH 01b @ 11Mbps Bit-Rate) ‚ Relative Humidity: 70 % ‚ Temperature: 24°C ‚ Test Date: Nov. 28, 2003 ‚ Power Supply System: AC Power: 230Vac 50Hz ‚ Test Set-up: Table-top Equipment ‚ All emissions not reported here are more than 10 dB below the prescribed limit. ■ The test was passed at the minimum margin that marked under gray area in the following table (802.11b) (MHz) N L1 N L1 (dB) N L1 N L1 0.322 41.8 51.7 --- --- 0.3 42.1 52 --- --- 59.7 49.7 -7.70 --- 0.408 42.2 39 --- --- 0.3 42.5 39.3 --- --- 57.7 47.7 -15.20 --- 0.443 44.2 45.2 --- --- 0.3 44.5 45.5 --- --- 57.7 47.0 -11.50 --- 0.785 31.6 46 --- --- 0.3 31.9 46.3 --- --- 56.0 46.0 -9.70 --- 0.84 29.8 33.5 --- --- 0.3 30.1 33.8 --- --- 56.0 46.0 -22.20 --- 0.895 28.4 31.4 --- --- 0.3 28.7 31.7 --- --- 56.0 46.0 -24.30 --- AVG. Limit (dBuV) Q.P Value AVG. Value Margins (dB) Q.P Factor Result (dBuV) Q.P Value AVG. Value Freq. Q.P Value Meter Reading (dBuV) AVG. Value Notes: 1. The EUT was placed 0.8m above reference ground plane. 2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value doesn’t need to be measured. 3. The expanded uncertainty of the conducted emission tests is 2.45 dB.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 27 of 27 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 28 of 28 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 29 of 29 EMC Test Report: CE03111004-A 19.1.1 Test Mode 2 (CH 07b @ 11Mbps Bit-Rate) ‚ Relative Humidity: 70 % ‚ Temperature: 24°C ‚ Test Date: Nov. 28, 2003 ‚ Power Supply System: AC Power: 230Vac 50Hz ‚ Test Set-up: Table-top Equipment ‚ All emissions not reported here are more than 10 dB below the prescribed limit. ■ The test was passed at the minimum margin that marked under gray area in the following table (MHz) N L1 N L1 (dB) N L1 N L1 0.17 56.6 54.1 25.5 23.4 0.2 56.8 54.3 25.7 23.6 65.0 55.0 -8.2 -29.3 0.259 48.5 38.9 21.4 19.9 0.2 48.7 39.1 21.6 20.1 61.5 51.5 -12.7 -29.8 0.459 44.9 46 19.2 22 0.3 45.2 45.3 19.5 22.3 56.7 46.7 -10.4 -24.4 0.855 28.2 33 14.2 10.8 0.3 28.5 33.3 14.5 11.1 56.0 46.0 -22.7 -31.5 1.281 28.7 32 14.7 14.2 0.4 29.1 32.4 15.1 14.6 56.0 46.0 -23.6 -30.9 1.754 19.8 32.1 9.4 10.7 0.5 20.3 32.6 9.9 11.2 56.0 46.0 -23.4 -34.8 AVG. Limit (dBuV) Q.P Value AVG. Value Margins (dB) Q.P Factor Result (dBuV) Q.P Value AVG. Value Freq. Q.P Value Meter Reading (dBuV) AVG. Value Notes: 1. The EUT was placed 0.8m above reference ground plane. 2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value doesn’t need to be measured. 3. The expanded uncertainty of the conducted emission tests is 2.45 dB.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 30 of 30 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 31 of 31 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 32 of 32 EMC Test Report: CE03111004-A 19.1.2 Test Mode 3 (CH 13b@ 11Mbps Bit-Rate) ‚ Relative Humidity: 70 % ‚ Temperature: 24°C ‚ Test Date: Nov. 28, 2003 ‚ Power Supply System: AC Power: 230Vac 50Hz ‚ Test Set-up: Table-top Equipment ‚ All emissions not reported here are more than 10 dB below the prescribed limit. ■ The test was passed at the minimum margin that marked under gray area in the following table (MHz) N L1 N L1 (dB) N L1 N L1 0.373 46 53.3 --- 22.6 0.3 46.3 53.6 --- 22.9 58.4 48.4 -4.9 -25.6 0.539 38.2 45.2 --- 21.8 0.3 38.5 45.5 --- 22.1 56.0 46.0 -10.5 -23.9 0.609 35.5 47.5 --- 17.7 0.3 35.8 47.8 --- 18 56.0 46.0 -8.2 -28 0.789 29.9 42.9 --- 21.3 0.3 30.2 43.2 --- 21.6 56.0 46.0 -12.8 -24.4 1.004 31.4 34.7 --- 11.7 0.3 31.7 35 --- 12 56.0 46.0 -21.0 -34 1.07 32.1 33.4 --- 10.9 0.3 32.4 33.7 --- 11.2 56.0 46.0 -22.3 -34.8 Freq. Q.P Value Meter Reading (dBuV) AVG. Value Factor Result (dBuV) Q.P Value AVG. Value AVG. Limit (dBuV) Q.P Value AVG. Value Margins (dB) Q.P Notes: 1. The EUT was placed 0.8m above reference ground plane. 2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value doesn’t need to be measured. 3. The expanded uncertainty of the conducted emission tests is 2.45 dB.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 33 of 33 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 34 of 34 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 35 of 35 EMC Test Report: CE03111004-A 19.1.3 Test Mode 4 (CH 01g@ 54Mbps Bit-Rate) ‚ Relative Humidity: 70 % ‚ Temperature: 24°C ‚ Test Date: Nov. 28, 2003 ‚ Power Supply System: AC Power: 230Vac 50Hz ‚ Test Set-up: Table-top Equipment ‚ All emissions not reported here are more than 10 dB below the prescribed limit. ■ The test was passed at the minimum margin that marked under gray area in the following table 802.11g (MHz) N L1 N L1 (dB) N L1 N L1 0.193 54.7 47.5 24.6 --- 0.2 54.9 47.7 24.8 --- 63.9 53.9 -9.0 -29.1 0.664 37.6 47.1 18.1 --- 0.3 37.9 47.4 18.4 --- 56.0 46.0 -8.6 -27.6 0.688 36.8 36.1 12.3 --- 0.3 37.1 36.4 12.6 --- 56.0 46.0 -18.9 -33.4 0.934 29.9 34.2 17.1 --- 0.3 30.2 34.5 17.4 --- 56.0 46.0 -21.5 -28.6 1.065 32.3 34.2 11.1 --- 0.3 32.6 34.5 11.4 --- 56.0 46.0 -21.5 -34.6 1.703 26.8 30.3 22.4 --- 0.4 27.2 30.7 22.8 --- 56.0 46.0 -25.3 -23.2 Freq. Q.P Value Meter Reading (dBuV) AVG. Value Factor Result (dBuV) Q.P Value AVG. Value AVG. Limit (dBuV) Q.P Value AVG. Value Margins (dB) Q.P Notes: 1. The EUT was placed 0.8m above reference ground plane. 2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value doesn’t need to be measured. 3. The expanded uncertainty of the conducted emission tests is 2.45 dB.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 36 of 36 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 37 of 37 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 38 of 38 EMC Test Report: CE03111004-A 19.1.4 Test Mode 5 (CH 07g @ 54Mbps Bit - Rate) ‚ Relative Humidity: 70 % ‚ Temperature: 24°C ‚ Test Date: Nov. 28, 2003 ‚ Power Supply System: AC Power: 230Vac 50Hz ‚ Test Set-up: Table-top Equipment ‚ All emissions not reported here are more than 10 dB below the prescribed limit. ■ The test was passed at the minimum margin that marked under gray area in the following table (MHz) N L1 N L1 (dB) N L1 N L1 0.209 53.3 55.6 22.6 25.1 0.2 53.5 55.8 22.8 25.3 63.3 53.3 -7.7 -28 0.412 46.7 43.7 18.1 16.1 0.3 47 44 18.4 16.4 57.6 47.6 -10.6 -29.2 0.47 44.7 38.8 19 14.5 0.3 45 39.1 19.3 14.8 56.5 46.5 -11.5 -27.2 0.988 31.4 47.4 13 17.6 0.3 31.7 47.7 13.3 18.9 56.0 46.0 -8.3 -28.1 1.043 32.1 36 11.2 12.3 0.3 32.4 36.3 11.5 12.6 56.0 46.0 -19.7 -33.4 1.141 30.7 38.8 15.1 12.3 0.3 31 39.1 15.4 12.6 56.0 46.0 -16.9 -30.6 AVG. Limit (dBuV) Q.P Value AVG. Value Margins (dB) Q.P Factor Result (dBuV) Q.P Value AVG. Value Freq. Q.P Value Meter Reading (dBuV) AVG. Value Notes: 1. The EUT was placed 0.8m above reference ground plane. 2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value doesn’t need to be measured. 3. The expanded uncertainty of the conducted emission tests is 2.45 dB.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 39 of 39 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 40 of 40 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 41 of 41 EMC Test Report: CE03111004-A 19.1.5 Test Mode 6 (CH 13g@ 54Mbps Bit - Rate) ‚ Relative Humidity: 70 % ‚ Temperature: 24°C ‚ Test Date: Nov. 28, 2003 ‚ Power Supply System: AC Power: 230Vac 50Hz ‚ Test Set-up: Table-top Equipment ‚ All emissions not reported here are more than 10 dB below the prescribed limit. ■ The test was passed at the minimum margin that marked under gray area in the following table (MHz) N L1 N L1 (dB) N L1 N L1 0.205 53.7 55.5 22.9 24.9 0.2 53.9 55.7 23.1 25.1 63.4 53.4 -7.7 -28.3 0.295 38.9 41.5 13.5 14.7 0.2 39.1 41.7 13.7 14.9 60.4 50.4 -18.6 -35.4 0.369 46.8 40.8 17 15.1 0.3 47.1 41.1 17.3 15.4 58.5 48.5 -11.4 -31.2 0.408 47.1 48.2 18.7 18 0.3 47.4 48.5 19 18.3 57.7 47.7 -9.2 -28.7 0.443 46 36 17.2 15.8 0.3 46.3 36.3 17.5 16.1 57.0 47.0 -10.7 -29.5 0.559 35.7 32.4 12.3 10.8 0.3 36 32.7 12.6 11.1 56.0 46.0 -20.0 -33.4 Freq. Q.P Value Meter Reading (dBuV) AVG. Value Factor Result (dBuV) Q.P Value AVG. Value AVG. Limit (dBuV) Q.P Value AVG. Value Margins (dB) Q.P Notes: 1. The EUT was placed 0.8m above reference ground plane. 2. The symbol of “---” means the Q.P. value is under the limit for AVG. so, the AVG. value doesn’t need to be measured. 3. The expanded uncertainty of the conducted emission tests is 2.45 dB.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 42 of 42 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 43 of 43 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 44 of 44 EMC Test Report: CE03111004-A 19.2. Photographs of Conducted Powerline Test Configuration z The photographs show the configuration that generates the maximum emission. FRONT VIEW REAR VIEW

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 45 of 45 EMC Test Report: CE03111004-A 20. Test Result of Radiated Emission 20.1. Test Mode 1 (TX / RX @ 11Mbps Bit – Rate) ‚ Relative Humidity: 70 % ‚ Temperature: 24°C ‚ Test Date: Nov. 28, 2003 ‚ Power Supply System: AC Power: 230Vac 50Hz ‚ Test Set-up: Table-top Equipment ‚ All emissions not reported here are more than 10 dB below the prescribed limit. ■ The test was passed at the minimum margin that marked under gray area in the following table (802.11b) Emission frequency CORR'd Factor Limit (10m) (MHz) HOR. VERT. (dB) HOR. VERT. (dBuV/m) 34.619 35.9 36.1 -11.4 24.5 24.7 30 -5.3 106.481 36.7 37.2 -12.9 23.8 24.3 30 -5.7 163.992 35.4 37.3 -13.5 21.9 23.8 30 -6.2 173.408 38.4 39 -13.8 24.6 25.2 30 -4.8 212.525 39 39.4 -13.3 25.7 26.1 30 -3.9 256.773 40 41.2 -9.5 30.5 31.7 37 -5.3 Meter Reading (dBuV) Results (dBuV/m) Margins (dB) Notes: 1. Measurement Distance: 10m 2. Height of table on which the EUT was placed: 0.8m 3. Height of Receiving Antenna: 1 - 4m 4. Remark “---“ means that the emissions level is too low to be measured. 5. The expanded uncertainty of the radiated emission tests is 3.53 dB.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 46 of 46 EMC Test Report: CE03111004-A 20.1.1 Test Mode 2 (TX / RX @ 54Mbps Bit - Rate) ‚ Relative Humidity: 70 % ‚ Temperature: 24°C ‚ Test Date: Nov. 28, 2003 ‚ Power Supply System: AC Power: 230Vac 50Hz ‚ Test Set-up: Table-top Equipment ‚ All emissions not reported here are more than 10 dB below the prescribed limit. ■ The test was passed at the minimum margin that marked under gray area in the following table (802.11g) Emission frequency CORR'd Factor Limit (10m) (MHz) HOR. VERT. (dB) HOR. VERT. (dBuV/m) 47.696 41.1 42.4 -17.7 23.4 24.7 30 -5.3 105.711 37.8 37.6 -13.1 24.7 24.5 30 -5.3 158.964 39.1 38.1 -13.3 25.8 24.8 30 -4.2 190.401 40.3 39.8 -13.9 26.4 25.9 30 -3.6 256.748 36.8 37.6 -9.5 27.3 28.1 37 -8.9 271.636 39.7 40.7 -10.3 29.4 30.4 37 -6.6 Meter Reading (dBuV) Results (dBuV/m) Margins (dB) Notes: 1. Measurement Distance: 10m 2. Height of table on which the EUT was placed: 0.8m 3. Height of Receiving Antenna: 1 - 4m 4. Remark “---“ means that the emissions level is too low to be measured. 5. The expanded uncertainty of the radiated emission tests is 3.53 dB.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 47 of 47 EMC Test Report: CE03111004-A 20.2. Photographs of Radiated Emission Test Configuration z The photographs show the configuration that generates the maximum emission. FRONT VIEW REAR VIEW

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 48 of 48 EMC Test Report: CE03111004-A 21. Harmonics Test Basic Standard : EN 61000-3-2:1995/A1/A2:1998/A14:2000 AC Power : 230Vac 50Hz Temperature : 25 ℃ Test Data : Nov. 28, 2003 Relative Humidity : 50 % RH Urms = 230.1V Freq = 49.984 Range: 0.25A Irms = 0.043A Ipk = 0.075A cf = 1.749 P = 6.393W Pap = 9.859VA pf = 0.648 THDi = 43.00% THDu = 0.10% Calss A Test-Time: 3min (100%) Test completed Result: PASSED Order Freq. (Hz) Imax (A) Limit (A) Order Freq. (Hz) Imax (A) Limit (A) 1 50 0.121 21 1050 0.0002 0.1071 2 100 0.0005 1.08 22 1100 0 0.0836 3 150 0.0133 2.3 23 1150 0.0003 0.0978 4 200 0.0002 0.43 24 1200 0 0.0767 5 250 0.0127 1.14 25 1250 0.0002 0.09 6 300 0.0001 0.3 26 1300 0 0.0708 7 350 0.0024 0.77 27 1350 0.0002 0.0833 8 400 0.0001 0.23 28 1400 0 0.0657 9 450 0.0015 0.4 29 1450 0.0002 0.0766 10 500 0 0.184 30 1500 0 0.0613 11 550 0.0016 0.33 31 1550 0.0001 0.0726 12 600 0 0.1533 32 1600 0 0.0575 13 650 0.0008 0.21 33 1650 0.0001 0.0682 14 700 0 0.1314 34 1700 0 0.0541 15 750 0.0005 0.15 35 1750 0.0001 0.0643 16 800 0 0.115 36 1800 0 0.0511 17 850 0.0005 0.1324 37 1850 0.0001 0.0608 18 900 0 0.1022 38 1900 0 0.0484 19 950 0.0003 0.1184 39 1950 0.0001 0.0577 20 1000 0 0.092 40 2000 0 0.046

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 49 of 49 EMC Test Report: CE03111004-A 22. Voltage Fluctuations Test z Basic Standard : EN 61000-3-3:1995/A1:1998 z FINAL TEST RESULT : PASS z Temperature : 25 ℃ z Test Data : Nov. 28, 2003 z Relative Humidity : 50 % RH Pst Plt Dc ( % ) Dmax ( % ) Dt ( % ) Reading 0.070 0.070 0.00 0.00 0.00 Limit 0.65 1.0 3.0 4.0 3.0 22.1. TEST EQUIPMENT SETTINGS z Line Voltage : 230 V z Test Duration : 00:10:00 minutes z Line Frequency : 50 Hz z Measurement Delay : 10.0 seconds z Pst Integration Periods : 1 z Pst Integration Time : 10 minutes

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 50 of 50 EMC Test Report: CE03111004-A 22.2. Photographs of Harmonics test, Voltage Fluctuation and Flicker test Harmonics test Flicker test

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 51 of 51 EMC Test Report: CE03111004-A 23. Electrostatic Discharge Immunity Test (ESD) Final Test Result : PASS Pass performance Criteria : TT/TR Required performance criteria : TT/TR Basic Standard : EN 61000-4-2:1995/A1:1998/A2:2000 Product Standard EN 301 489-17 Level : 3 for air discharge, 2 for contact discharge Test Voltage : ±2 / ±4 / ±8 KV for air discharge, ±2 / ±4 KV for contact discharge Temperature : 25 °C Relative Humidity : 60% Test Date : Nov. 28, 2003 Observation : Normal 23.1. Test Severity Levels Contact Discharge Air Discharge Level Test Voltage (KV) of Contact discharge Level Test Voltage (KV) of Air Discharge 1 ±2 1 ±2 2 ±4 2 ±4 3 ±6 3 ±8 4 ±8 4 ±15 X Specified X Specified Remark: “X” is an open level.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 52 of 52 EMC Test Report: CE03111004-A 23.2. Test Result of Air Discharge/ Contact Discharge Energy-Storage Capacitor: 150 pF Discharge Resistor : 330 Ω Contact Discharge Times: 10 times/each condition Air Discharge Times : 10 times/each condition \Discharge Mode Contact Discharge Air Discharge \ESD Voltage 2 KV 4 KV KV KV 2 KV 4 KV 8 KV KV \Points \Result \Polarity + - + - + - + - + - + - + - + - VCP N N N N --- --- --- --- --- --- --- --- --- --- --- --- HCP N N N N --- --- --- --- --- --- --- --- --- --- --- --- P1~P7 --- --- --- --- --- --- --- --- N N N N N N --- --- P8 N N N N --- --- --- --- --- --- --- --- --- --- --- --- Note: ”N” means the EUT function was correct during the test. ” --- “means the test could not be carrier out.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 53 of 53 EMC Test Report: CE03111004-A 23.3. Photographs of Electrostatic Discharge Immunity Test

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 54 of 54 EMC Test Report: CE03111004-A

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 55 of 55 EMC Test Report: CE03111004-A 24. Radio Frequency Electromagnetic Field Immunity Test (RS) Final Test Result : PASS Pass performance Criteria : CT/CR Required performance criteria : CT/CR Basic Standard : EN 61000-4-3:1996/A1:1998/A2:2000 Product Standard EN 301 489-17 Level : 2 Frequency Range : 80-1000 MHz; 1400-2000 MHz Field Strength : 3 V/m (Modulated 80% AM) Temperature : 26 °C Relative Humidity : 65 % Test Date : Nov. 28, 2003 Observation : Normal 24.1. Test Severity Levels Frequency Range (MHz) Test Axis Polarization of Device Test Result 80~1000 1400~2000 x- axis Vertical N 80~1000 1400~2000 y- axis Vertical N 80~1000 1400~2000 z- axis Vertical N Note: “ N ” means the EUT function was correct during the test.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 56 of 56 EMC Test Report: CE03111004-A 24.2. Photographs of Radio Frequency Electromagnetic Field Immunity Test

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 57 of 57 EMC Test Report: CE03111004-A 25. Electrical Fast Transient/Burst Immunity Test (EFT/BURST) Final Test Result : PASS Pass performance Criteria : CT/CR Required performance criteria : TT/TR Basic Standard : EN61000-4-4:1995/A1:200 Product Standard EN 301 489-17 Level : 2 Test Voltage : on Power Supply -- ±1.0 KV on I/O signal, data and control line -- ±0.5 KV Temperature : 25 °C Relative Humidity : 60 % Test Date : Nov. 28, 2003 Observation : Normal 25.1. Test Severity Levels 0.5 kV 1.0 kV \Voltage\Polarity \Test Point\Mode\Result + - + - L N N N N N N N N N Power Line L-N N N N N LAN Line N N --- --- Note: “N” means the EUT function was correct during the test. “---“means the test could not be carrier out.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 58 of 58 EMC Test Report: CE03111004-A 25.2. Photographs of Electrical Fast Transient/BURST Immunity Test

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 59 of 59 EMC Test Report: CE03111004-A 26. Surge Immunity Test FINAL TEST RESULT : PASS Pass performance Criteria : CT/CR Required performance criteria : TT/TR Basic Standard : EN 61000-4-5 :1995/A1:2000 Product Standard EN 301 489-17 Surge wave form (Tr/Th) : 1, 2/50(8/20)µs Level : on Signal ports And Telecommunication – N/A on Input AC Power Port -- 2 Test Voltage : on Signal ports And Telecommunication – N/A on Input AC Power Port -- ±1.0 KV Temperature : 25 °C Relative Humidity : 60 % Test Date : Nov. 28, 2003 Remark : “ N “ means the EUT function was correct during the test. Angle ; 0° ; 90° ; 180° ; 270° ; 360° Voltage ( KV ): 0.5 kV Test Location: L-N Test Result: PASS 26.1. TEST LEVEL \Phase \Voltage \Mode \Polarity \Result 0° 90° 180° 270° 360° + N N N N N 0.5 kV L-N - N N N N N Note: “N” means the EUT function was correct during the test.

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 60 of 60 EMC Test Report: CE03111004-A 26.2. Photographs of Surge Immunity Test

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 61 of 61 EMC Test Report: CE03111004-A 27. Conducted Disturbances Induced by Radio-Frequency Field Immunity Test (CS) Final Test Result : PASS Pass performance Criteria : CT/CR Required performance criteria : CT/CR Basic Standard : EN 61000-4-6 :1996/A1:2000 Product Standard EN 301 489-17 Level : 2 Test Voltage 3 V rms ( Modulated, 1KHz, 80%, AM ) Frequency Range 0.15 MHz to 80 MHz Dwell time 2.9 seconds Frequency step size 1 % Coupling mode CDN-M2 for AC power ports, Clamp for Signal Ports Temperature : 25 °C Relative Humidity : 50 % Test Date : Nov. 28, 2003 Observation : Normal 27.1. TEST LEVEL Frequency Range (MHz) Tested Line Test Result 0.15~80 Power Line N 0.15~80 LAN Line N Note: “N” means the EUT function was correct during the test. 27.2. OPERATING CONDITION Full system

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 62 of 62 EMC Test Report: CE03111004-A 27.3. Photographs of CS Tests Power Line LAN Line

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 63 of 63 EMC Test Report: CE03111004-A 28. Voltage Dips and Voltage Interruptions Immunity Tests Final Test Result : PASS Pass performance Criteria TT/TR for voltage interruption, CT/CR and TT/TR for voltage dips Required performance criteria TT/TR for voltage interruption, TT/TR for voltage dips Basic Standard : EN 61000-4-11:1994/A4:2000 Product Standard EN 301 489-17 Temperature : 25 °C Relative Humidity : 50 % Test Date : Nov. 28, 2003 28.1. TEST LEVEL TEST RECORD OF VOLTAGE INTERRUPTION/ DIPS Test mod Voltage dips Durations (period / ms) Interval(s) Times Phase Result Voltage interruptions 100% 5000 10 12 0°/180° B 60% 100 10 12 0°/180° N Voltage dips in %UT 30% 10 10 12 0°/180° N Note: “N” means the EUT function was correct during test. “B” means the EUT’s function was fail during the test, the EUT operate as intended without operator intervention. EMS Test Engineer: Kevin Lee

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 64 of 64 EMC Test Report: CE03111004-A 28.2. Photographs of Voltage Dips and Voltage Interruptions Immunity Tests

Exclusive Certification Corp. Tel:886-2-2792-3366 Fax:886-2-2792-1100

Issued date: Dec. 16, 2003 65 of 65 EMC Test Report: CE03111004-A 29. List of Measuring Equipment Used (EMS) Test Equipment Calibration Date Recommended Recal. Date EMC Emission Tester EMC-Partner Harnmonics-1000 Sep.06,2003 Sep.05,2004 EMC Immunity tester\EMC-Partener\TRANSIENT-1000 Oct.17,2003 Oct.16,2004 Metering Unit & Probe\EMCO\7122 Oct.30,2003 Oct.29,2004 SMGL Generator\Agilent\83640B Jun.23,2003 Jun.22,2004 Amplifier\ar\50S1G4AM1 Jun.23,2003 Jun,22,2004 Test System : FRANKONIA EMV-Mess-System GmbH\CIT-10 Feb.18,2003 Feb.17,2004 CDN : FRANKONIA EMV-Mess-System GmbH\CDN M2+M3 Jul.17,2003 Jul.16,2004 EM-Clamp : Schaffner\KEMZ801 Feb.09,2003 Feb.08,2004