TPI 665 Instruction Manual

Specifications

Brand: TPI
Category: Measuring Instruments
Model: 665 (Instruction Manual)
File Type: PDF
File Size: —
Pages: 16

Read Online

Read the TPI 665 Instruction Manual online using the built-in PDF viewer.

Text of the manual

Differential Input Logging

Manometer Instruction Manual www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

Thank you for purchasing TPI products. The 665 is easy

to use and is built to last. It is backed by a 3 year limit- ed warranty. Please remember to complete and return your product warranty registration card. 2. Product Description The slim design 665 is a hand-held, differential input manometer with data logging capability. Digital filter, min/max, one touch zero, and backlight display are just a few of the features of the 665. The 665 comes complete with the following accessories: Instruction Manual Battery TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations..................................................3 2. Product Description ..........................................3 B. SAFETY CONSIDERATIONS..........................................4 C. TECHNICAL DATA 1. Features and Benefits ........................................5 2. Specifications ....................................................6 D. CONTROLS & FUNCTIONSS..........................................7 . E. MAKING A MEASUREMENT ........................................9 F. SAVING DATA ......................................................10 G. LOADING SAVED DATA ..............................................10 H. MIN / MAX ............................................................10 I. PRINTING DATA ....................................................10 J. CHANGING DATE & TIME ..........................................11 K. LOGGING DATA .... .............................................12 L. PC COMMUNICATION ................................................16 M. MAINTENANCE ....................................................16 N. TROUBLE SHOOTING AND SERVICE ........................17 O. ACCESSORIES ....................................................18 2 3 www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

B. SAFETY CONSIDERATIONS

WARNING: Please follow manufacturers test procedures whenever possible. Do not attempt to measure unknown pressures. Damage to the instru- ment may result. GENERAL GUIDELINES ALWAYS • Ensure connections are secure prior to applying pres- sure. • Inspect hoses and fittings for cracks or bends prior to a pressure test. • Make sure the instrument battery is in good condition and there is no lo battery indication in the display. • Have someone check on you periodically if working alone. NEVER • Attempt to measure unknown high pressures. C. TECHNICAL DATA 1. Features and Benefits Display 5 digit dual line with backlight Units of Seven units of measure (bar, kPa, Measure PSI, mmHg, inHg, mmH2O, inH2O). Logging Record test data with time stamp and display with optional software. Data Store Save up to 16 readings. MAX/MIN Records Min/Max readings Auto Off Conserve batteries. www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

B. SAFETY CONSIDERATIONS

WARNING: Please follow manufacturers test procedures whenever possible. Do not attempt to measure unknown pressures. Damage to the instru- ment may result. GENERAL GUIDELINES ALWAYS • Ensure connections are secure prior to applying pres- sure. • Inspect hoses and fittings for cracks or bends prior to a pressure test. • Make sure the instrument battery is in good condition and there is no lo battery indication in the display. • Have someone check on you periodically if working alone. NEVER • Attempt to measure unknown high pressures. C. TECHNICAL DATA 1. Features and Benefits Display 5 digit dual line with backlight Units of Seven units of measure (bar, kPa, Measure PSI, mmHg, inHg, mmH2O, inH2O). Logging Record test data with time stamp and display with optional software. Data Store Save up to 16 readings. MAX/MIN Records Min/Max readings Auto Off Conserve batteries. www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

Measurement Range: ±101.5 psi (±7bar)

Display: 5 Digit Dual line LCD with backlight Input Type: Differential Resolution (max): 0.01 psi (0.001 bar) (0.1 inH2O) Accuracy: 0.2% Full scale Repeatability: 0.1% Full scale Mean Temperature Coefficient: 0.1% of reading per ºC Functions: One Touch Zero, Data Hold, Back-light, Unit Selection, Data Logging, Auto power Off, Min / Max Record, Resolution Selection Units of Measure: 7Units (bar, kPa, PSI, mmHg, inHg, mmH2O, inH2O) Data logging: 5000 Data, 1sec ~ 24 hour. Data Storage: 16 data points Communication: IR to USB Interface and PC Application soft- ware (optional p/n A665) Battery Type: AA(1.5V)*2 alkaline (MN1500, LR6) Battery Life: 600hour (Typical) Auto Power Off: 20 minutes (can be disabled) D. CONTROLS & FUNCTIONS Input Connectors (1/4” NPT) Keypad IR Ports for PC communica- tion using optional A665 docking station IR Port for printing using optional A740 print- er Display www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

Measurement Range: ±101.5 psi (±7bar)

Display: 5 Digit Dual line LCD with backlight Input Type: Differential Resolution (max): 0.01 psi (0.001 bar) (0.1 inH2O) Accuracy: 0.2% Full scale Repeatability: 0.1% Full scale Mean Temperature Coefficient: 0.1% of reading per ºC Functions: One Touch Zero, Data Hold, Back-light, Unit Selection, Data Logging, Auto power Off, Min / Max Record, Resolution Selection Units of Measure: 7Units (bar, kPa, PSI, mmHg, inHg, mmH2O, inH2O) Data logging: 5000 Data, 1sec ~ 24 hour. Data Storage: 16 data points Communication: IR to USB Interface and PC Application soft- ware (optional p/n A665) Battery Type: AA(1.5V)*2 alkaline (MN1500, LR6) Battery Life: 600hour (Typical) Auto Power Off: 20 minutes (can be disabled) D. CONTROLS & FUNCTIONS Input Connectors (1/4” NPT) Keypad IR Ports for PC communica- tion using optional A665 docking station IR Port for printing using optional A740 print- er Display www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

1. Turn the 665 by pressing the

2. Zero the 665 by pressing 3. Connect the device under test to the “+” port of the 665. If a differential measurement is being made, connect the other pressure source to the “-” port. Note: Any pressure connected to the “-” port will be subtracted from the “+” port and the result will be displayed. 4. Read the measurement in the display. 5. Remove pressure prior to diconnecting the lines from the inputs. During a measurement the following functions can be used. 9 8 D. CONTROLS & FUNCTIONS (Continued) Press to turn the 665 on. Press to activate the display backlight. Backlight powers off after 15 seconds. Press the SHIFT key first then this key to acti- vate the digital filter. Use to smooth fast chang- ing measurements. Press to activate “blue” functions (Load, Save, Min, Max). “EXP” will display when active. Press the SHIFT key first, then this key to turn the 665 off. Press to activate/deactivate the display hold. Press the SHIFT key first, then this key to print readings to the optional A740 printer. Press to select resolution and confirm menu selections. Press the SHIFT key first, then this key to turn deactivate/activate auto power off. Press to change the unit of measure. Press the SHIFT key first, then this key to zero the 665 prior to making a measurement. Press to activate shift mode (red key functions). Press to cycle through bottom display modes (percent of fullscale, current time, number of logged readings. Press the SHIFT key first, then this key to acti- vate EDIT mode. Press to display number of logs made. Press the SHIFT key first, then this key to acti- vate/deactivate log mode. E. Making a Measurement Activates the display backlight. Backlight powers off after 15 seconds. key. Press to change the unit of measure. Press to activate/deactivate the display hold. Press to select resolution. Press to cycle the bottom display through cur- rent time, ration in percent of reading compared to full scale, and number of logged data (NUM) Press the SHIFT key first then this key to acti- vate the digital filter. Use to smooth fast chang- ing measurements. There are many other features such as data storage and log- ging that can be used. Please see next sections. www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

1. Turn the 665 by pressing the

2. Zero the 665 by pressing 3. Connect the device under test to the “+” port of the 665. If a differential measurement is being made, connect the other pressure source to the “-” port. Note: Any pressure connected to the “-” port will be subtracted from the “+” port and the result will be displayed. 4. Read the measurement in the display. 5. Remove pressure prior to diconnecting the lines from the inputs. During a measurement the following functions can be used. 9 8 D. CONTROLS & FUNCTIONS (Continued) Press to turn the 665 on. Press to activate the display backlight. Backlight powers off after 15 seconds. Press the SHIFT key first then this key to acti- vate the digital filter. Use to smooth fast chang- ing measurements. Press to activate “blue” functions (Load, Save, Min, Max). “EXP” will display when active. Press the SHIFT key first, then this key to turn the 665 off. Press to activate/deactivate the display hold. Press the SHIFT key first, then this key to print readings to the optional A740 printer. Press to select resolution and confirm menu selections. Press the SHIFT key first, then this key to turn deactivate/activate auto power off. Press to change the unit of measure. Press the SHIFT key first, then this key to zero the 665 prior to making a measurement. Press to activate shift mode (red key functions). Press to cycle through bottom display modes (percent of fullscale, current time, number of logged readings. Press the SHIFT key first, then this key to acti- vate EDIT mode. Press to display number of logs made. Press the SHIFT key first, then this key to acti- vate/deactivate log mode. E. Making a Measurement Activates the display backlight. Backlight powers off after 15 seconds. key. Press to change the unit of measure. Press to activate/deactivate the display hold. Press to select resolution. Press to cycle the bottom display through cur- rent time, ration in percent of reading compared to full scale, and number of logged data (NUM) Press the SHIFT key first then this key to acti- vate the digital filter. Use to smooth fast chang- ing measurements. There are many other features such as data storage and log- ging that can be used. Please see next sections. www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

Press to print readings to the optional A740

printer. Press to save displayed readings. Data automat- ically saved in one of 16 locations. Press to display the minimum reading mea- sured. F. Saving Data During a measurement data can be saved for retrieval later. Follow these steps. Press to display the maximum reading mea- sured. Press to display saved data. The stored data will be shown in the main display and the storage location will be dispalyed on the bottom display. G. Loading Saved Data While “EXP” is displayed pressing the key will cycle the storage location up and pressing the key will cycle the storage location down. This data can be printed also. Please see section I. H. MIN / MAX I. Printing Data (requires A740 printer) The 665 will display a 10 second countdown giving you time to align the back holes approximately 4” away from the printer win- dow. “Out” will display and a 9 second countdown will proceed while printing takes place. Saved data can be printed also after loading data as outlined in section H. J. Changing the Date & Time 1. Activate “EDIT” mode by pressing 2. Press 3. Press and to cycle through month, day, and year. 4. Press and to change the month, day or year. 5. Once the date has been changed press 6. Press and “date” is displayed. and “date” is displayed. and “rtc” will be displayed. Press 7. The lower left display indicates hours, the lower right indi- cates minutes and the main display indicates seconds. 8. Press and to cycle through hours, minutes and seconds. 9. Press and to change the hours, minutes and seconds. 10. Exit “EDIT” mode by pressing www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

Press to print readings to the optional A740

printer. Press to save displayed readings. Data automat- ically saved in one of 16 locations. Press to display the minimum reading mea- sured. F. Saving Data During a measurement data can be saved for retrieval later. Follow these steps. Press to display the maximum reading mea- sured. Press to display saved data. The stored data will be shown in the main display and the storage location will be dispalyed on the bottom display. G. Loading Saved Data While “EXP” is displayed pressing the key will cycle the storage location up and pressing the key will cycle the storage location down. This data can be printed also. Please see section I. H. MIN / MAX I. Printing Data (requires A740 printer) The 665 will display a 10 second countdown giving you time to align the back holes approximately 4” away from the printer win- dow. “Out” will display and a 9 second countdown will proceed while printing takes place. Saved data can be printed also after loading data as outlined in section H. J. Changing the Date & Time 1. Activate “EDIT” mode by pressing 2. Press 3. Press and to cycle through month, day, and year. 4. Press and to change the month, day or year. 5. Once the date has been changed press 6. Press and “date” is displayed. and “date” is displayed. and “rtc” will be displayed. Press 7. The lower left display indicates hours, the lower right indi- cates minutes and the main display indicates seconds. 8. Press and to cycle through hours, minutes and seconds. 9. Press and to change the hours, minutes and seconds. 10. Exit “EDIT” mode by pressing www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

K. Logging Data

Setting Up Data Logging Interval 1. Activate “EDIT” mode by pressing 2. Press and “rtc” is displayed. 3. Press and “L-Int” is displayed. Press 4. The lower left display indicates hours, the lower right indi- cates minutes and the main display indicates seconds. 5. Press and to cycle through hours, minutes and seconds. 6. Press and to change the hours, minutes and seconds. 7. Exit logging interval mode by pressing This mode sets up the interval or time between each logged data point. The interval can be set from 1 second to 24 hours. The 665 can log a total of 5000 data points. NOTE: The option- al A665 docking station and software is required to view logged information. Logging can now be started and stopped manually or set to automatically start and stop. For automatic logging skip the steps below and see next page. Start and stop loggin by pressing To log manually exit edit mode by pressing K. Logging Data (continued) Setting Up Logging Start Time 1. The logging interval should already be set and the 665 should be displaying “L-Int”. If not, follow steps 1 through 7 on page 12 before proceeding. This mode sets up start time for automaitc logging. Logging can also be activated manually (See page 12). 2. Press and “L-St” is displayed. Press 3. The lower left display indicates hours, the lower right indi- cates minutes and the main display indicates seconds. 4. Press and to cycle through hours, minutes and seconds. 5. Press and to change the hours, minutes and seconds. 6. Exit logging interval mode by pressing The logging stop time must now be set. Please see page 14. www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

K. Logging Data

Setting Up Data Logging Interval 1. Activate “EDIT” mode by pressing 2. Press and “rtc” is displayed. 3. Press and “L-Int” is displayed. Press 4. The lower left display indicates hours, the lower right indi- cates minutes and the main display indicates seconds. 5. Press and to cycle through hours, minutes and seconds. 6. Press and to change the hours, minutes and seconds. 7. Exit logging interval mode by pressing This mode sets up the interval or time between each logged data point. The interval can be set from 1 second to 24 hours. The 665 can log a total of 5000 data points. NOTE: The option- al A665 docking station and software is required to view logged information. Logging can now be started and stopped manually or set to automatically start and stop. For automatic logging skip the steps below and see next page. Start and stop loggin by pressing To log manually exit edit mode by pressing K. Logging Data (continued) Setting Up Logging Start Time 1. The logging interval should already be set and the 665 should be displaying “L-Int”. If not, follow steps 1 through 7 on page 12 before proceeding. This mode sets up start time for automaitc logging. Logging can also be activated manually (See page 12). 2. Press and “L-St” is displayed. Press 3. The lower left display indicates hours, the lower right indi- cates minutes and the main display indicates seconds. 4. Press and to cycle through hours, minutes and seconds. 5. Press and to change the hours, minutes and seconds. 6. Exit logging interval mode by pressing The logging stop time must now be set. Please see page 14. www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

K. Logging Data (continued)

Setting Up Logging Start Time 1. The logging interval and start time should already be set and the 665 should be displaying “L-St”. If not, follow steps 1 through 7 on page 12 and steps 1 through 6 on page 13 before proceeding. This mode sets up stop time for automaitc logging. Logging can also be activated manually (See page 12). 2. Press and “L-Et” is displayed. Press 3. The lower left display indicates hours, the lower right indi- cates minutes and the main display indicates seconds. 4. Press and to cycle through hours, minutes and seconds. 5. Press and to change the hours, minutes and seconds. 6. Exit logging interval mode by pressing 7. To exit edit mode and return to normal operation press The LCD will display “REC” to remind you automatic logging is activated. “REC” will blink when log- ging is taking place. 8. Automatic logging can be deactivated. Please see page 15. K. Logging Data (continued) Deactivating Automatic Logging This mode turns off automatic logging. 1. Activate “EDIT” mode by pressing 2. Press six times until “L-res” is displayed. 3. Press and “L-rES” and “YES” is displayed. 4. Press or to cycle between NO (Cancel) and YES (Activate). 6. Once YES or NO is set press 7. Exit logging interval mode by pressing edit mode. to exit www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

K. Logging Data (continued)

Setting Up Logging Start Time 1. The logging interval and start time should already be set and the 665 should be displaying “L-St”. If not, follow steps 1 through 7 on page 12 and steps 1 through 6 on page 13 before proceeding. This mode sets up stop time for automaitc logging. Logging can also be activated manually (See page 12). 2. Press and “L-Et” is displayed. Press 3. The lower left display indicates hours, the lower right indi- cates minutes and the main display indicates seconds. 4. Press and to cycle through hours, minutes and seconds. 5. Press and to change the hours, minutes and seconds. 6. Exit logging interval mode by pressing 7. To exit edit mode and return to normal operation press The LCD will display “REC” to remind you automatic logging is activated. “REC” will blink when log- ging is taking place. 8. Automatic logging can be deactivated. Please see page 15. K. Logging Data (continued) Deactivating Automatic Logging This mode turns off automatic logging. 1. Activate “EDIT” mode by pressing 2. Press six times until “L-res” is displayed. 3. Press and “L-rES” and “YES” is displayed. 4. Press or to cycle between NO (Cancel) and YES (Activate). 6. Once YES or NO is set press 7. Exit logging interval mode by pressing edit mode. to exit www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

L. PC Communication

To communicate to a PC and view logged data the optional A665 docking station and software is required. Please refer to the instructions that come with the A665 for operating instructions. M. Maintenance Battery Replacement 1. Remove the protective rubber boot beginning at the bot- tom, 2. Using a screwdriver loosen the two screws located at the bottom of the 665. 3. Pull on the screws to remove the bottom cover/battery holder. 4. Remove the batteries and observing polarity replace them with fresh batteries. 5. Re-install the battery holder and tighten the screws. Cleaning Use a mild detergent and slightly damp cloth to clean the surfaces of the 665. N. Trouble Shooting & Service Problem Probable Causes Does not power up • Dead or defective battery “batt%” flashes in • Low battery indicator. Replace the lower display batteries Readings are high • Very weak battery that will not turn on the low battery indicator on the LCD OFL reads in the display • Indication of over pressure. Remove pressure source • If pressure source is removed and the 665 still displays “OL” the sensor is no longer working and the 665 needs service. To obtain service for your 665 please return it to: TPI / Attn: Service 9615 SW Allen Blvd Suite 104 Beaverton, OR 97005 www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

L. PC Communication

To communicate to a PC and view logged data the optional A665 docking station and software is required. Please refer to the instructions that come with the A665 for operating instructions. M. Maintenance Battery Replacement 1. Remove the protective rubber boot beginning at the bot- tom, 2. Using a screwdriver loosen the two screws located at the bottom of the 665. 3. Pull on the screws to remove the bottom cover/battery holder. 4. Remove the batteries and observing polarity replace them with fresh batteries. 5. Re-install the battery holder and tighten the screws. Cleaning Use a mild detergent and slightly damp cloth to clean the surfaces of the 665. N. Trouble Shooting & Service Problem Probable Causes Does not power up • Dead or defective battery “batt%” flashes in • Low battery indicator. Replace the lower display batteries Readings are high • Very weak battery that will not turn on the low battery indicator on the LCD OFL reads in the display • Indication of over pressure. Remove pressure source • If pressure source is removed and the 665 still displays “OL” the sensor is no longer working and the 665 needs service. To obtain service for your 665 please return it to: www.GlobalTestSupply.com Find Quality Products Online at: [email protected]