TZ75 Roller shutter controller

-1- On/off knob LED indicator Note: This module must be"Included in the network" , and suitable forwhere it will be permanently installed. The proper operation of this node in the mesh network is dependent on it knowing it's location with respect to other nodes. You can not "test bench" configure this module, then install. The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push button directly connected to this Roller Controller. TM The in-wall Roller Shutter Controller is a transceiver which is a Z-Wave enabled TM device and is fully compatible with any Z-Wave enabled network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutters.This in-wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method, so it can be remote controlled not only fully up

or down, but also can be adjusted to ex. 30% or 50%. And when manual controlled by

push button, the controller also can memorize the position and send the new shutter position to its controller (ex. IP-Gateway). TM Adding to Z-Wave Network In the front casing, there is an on/off button with LED indicator which is used to stop motor stalling or carry out inclusion, exclusion, reset or association.When first power is applied, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and can not work with Z-Wave enabled devices. The table below lists an operation summary of basic Z-Wave functions. Please refer TM to the instructions for your Z-Wave certificated primary controller to access the setup function, and to include/exclude/associate devices. function Description LED Indication No node ID Add Remove The Z-Wave controller does not allocate a node ID to the switch. 1.Have Z-Wave controller entered inclusion mode. 2. Pressing On/Off button three times within 1.5 seconds will enter inclusion mode. 1. Have Z-Wave controller entered exclusion mode. 2. Pressing On/Off button three times within 1.5 seconds will enter exclusion mode. 1-second on,1-second off Press for on Release for off Press for on Release for off function Description LED Indication Reset Association Node ID has been excluded. 1. Pressing On/off button three times within 1.5 seconds will enter inclusion mode. 2. Within 5 second, press On/Off button again for 1 seconds until LED is off. 3. IDs are excluded. 1. Have Z-Wave controller entered associaton mode. Or Pressing On/Off button three times within 1.5 seconds will enter association mode 2. There is only one group for the switch (it can associate max five devices) LED twinkle once Press for on Release for off LED twinkle once Press for on Release for off Including a node ID allocated by Z-Wave controller means Add. Excluding a node ID allocated by Z-Wave controller means Remove. Failed or success in including/excluding the node ID can be viewed from the Z-Wave controller. Association: it can be associated by Z-Wave devices with association Use the"Reset" procedure only in the event that the network primary controller is missing or otherwise inoperable

The group identifier is "Group 1".

Association group info report command class Profile: General lifeline (Profile MSB=0,Profile LSB=1) Association group name report command class Group 1: lifeline LED Indication To distinguish what mode the TZ75 is in, view from the LED for identification.No matter up or down, close or open, Led will flash every two seconds while Motor activate. Under normal operation, when the TZ75 has not been allocated a node ID,the LED flashes on and off alternately at 1-second intervals. By pressing S1,S2 0r Include button, it will stop flashing temporary. However, after disconnect and reconnect the TZ75, the LED will flash on and off alternately at . When overload state occurs, the TZ75 is disabled of which LED flashes on and off alternately at 0.5 second intervals. Overload state can be cleared by disconnect and reconnect the TZ75 to the main power. Installation an operation 1. Put the in wall TZ75 into a wall box and connect the AC power wire L, N to TZ75 connector L, N. 2. Connect the wall switch to the TZ75 . 3. lt is important to carry out a shutter calibration process before you control the shutter to move. Press inclusion button over 3 seconds and release before the 6th second, the roller shutter controller will start the shutter calibration process. The process is composed of three continue stages. The shutter move to the BOTTOM in first stage, and move to the TOP in second stage, and move to the BOTTOM again in 1-second intervals third stage. Then TZ75 will know the total range of UP and DOWN. 4. During the shutter calibration process, any emergencies happen you can press and release the include button to stop the process. 5. If user found the direction is reverse, this may because the wrong connection of NO1 and NO2 to the motor, please change NO1 and NO2 connection and execute calibration process again. 6. To manually switch up and down of the shutter, simply press S1or S2 . 7. TZ75 built in meter function and can read the Watt, KWh, V(Voltage), I(Current) PF(Power Factor) of the load by using Z-Wave command class. 8. TZ75 have overload protection function, and can help to prevent short circuit caused by load. Configuration Parameter Function Size (Byte) Value Unit Default Description 1 2 3 4 2 2 2 720 6 1100 0 0x01- 0x7FFF 10-1100 0-10000 Watt Meter Report period KWH Meter Report period Threshold of Watt for load caution Threshold of KWH for load caution 5s 5*720s=3600s =1 hour 6*1min=1 hour 10min 1 Watt Kwh 2 0x01- 0x7FFF Z-Wave Configuration Watt Meter Report Period: If the setting is configured for 1 hour (set value =720), the TZ75 will report its instant -5- -4-

power consumption every 1 hour to the node of correspond Group. The maximum

interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Default value is 1 hour KWH Meter Report Period: If the setting is configured for 1 hour (set value =6), the TZ75 will report its Accu- mulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Default value=1 hour Threshold of Watt for Load Caution This is a warning when the wattage of load over the preset threshold value, If the setting value is 1100, when the load wattage over this value, TZ75 will send Watt Meter Report command to the node of correspond Group. Default value=1100W. Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay 1 or Relay2 over this value, TZ75 will send KWh Meter Report command to the node of correspond Group, minimum value is 1 KWh . Default value is 0 kWh . It means no warning when the KWH of load over the preset threshold value and not send KWH Meter Report. Z-Wave Supported Command Class COMMAND_CLASS SWITCH_BINARY COMMAND_CLASS BASIC COMMAND_GLASS MANUFACTURER SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS ASSOCIATION COMMAND_CLASS METER_V3 COMMAND_CLASS CONFIGURATION COMMAND_CLASS SWITGH_ MULTILEVEL_V3 Wrong connection of NO1 and NO2 to the motor Swap the NO1 NO2 connection The shutter move direction is reverse Symptom Cause of Failure Recommendation The TZ75 not working and LED off 1. The TZ75 is not connect to the Main power 2. The TZ75 break down 1. Check power connections 2. Don't open up the TZ75 and send it for repair. TZ75 LED light work fine But can not control 1. No association setting 2. Same frequency interference 1. Carry out association 2. Wait for a while to retry Operating Voltage Maximum Load 110 240VAC Resistive Load 1100W/600W(EU/US) max Minimum 40m in door ,70m outdoor line of sight 0 40℃ 868.4MHz(EU) 908.42MHz(US) 921.42MHz(AUS) ~ ℃~ Range Operating temperature Frequency Range Specifications are subject to change and improvement without notice. Specification Troubleshooting -7- -6-

Product size (mm)

L:Line voltage input NO1,NO2: motor connector N: Line neutral S: Connect to wall switch input Warning: 1. Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities. 2. Contact your local government for information regarding the collection systems available. 3. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. 4. When replacing old appliances with new one, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. , TZ75-V1.0-2017.4.29 L N S2 S1 L N N M NO1 NO2 COM -9- -8- 16.5 39 46.6