TFA AMBIENTE II Manual
Text of the manual
Radio controlled time with manual setting option
l
Weather Forecast with Sunny, Slightly Cloudy, Cloudy, Rainy and Cloud Burst.
l
433MHz RF receiving frequency.
l
Maximum three selectable RF channels with wireless Thermo Sensor.
(One Wireless Thermo Sensor Included)
l
Transmission range: 30 meters ( open area ).
l
Measuring range:
Indoor temperature : 0°C ~ +50°C
Humidity : 20% ~ 99%
Outdoor temperature : -20°C ~ +50°C
l
Temperature Alert function.
l
Max/Min Memory for Humidity, Indoor and Outdoor Temperature.
l
Moon Phase Display.
l
High Tide, Medium Tide and Low Tide Indication.
l
Low-battery indicator for Outdoor Remote Sensor.
l
Perpetual Calendar Up to Year 2069.
l
12/24Hour time display selectable.
l
Day of week in 8 Languages Selectable.
l
Wall Mount or Table Stand Selectable.
l
Battery:
Main Unit : DC 1.5 V AA size x 2 pcs
Thermo Sensor Unit : DC 1.5 V AA size x 2 pcs
Main Unit Appearance
Part A- LCD
A1: Weather Forecast A2: Barometer Pressure Trend
A3: Outdoor Temperature A4: Outdoor Temperature Trend.
A5: Indoor Temperature. A6: Indoor Humidity
A7: Moon Phase & Tide Indication. A8: Radio Controlled Time Display
Part B- Buttons
B1: “MODE/SET” button B2: “SNOOZE” button.
B3: ”ALARM ON/OFF” button B4: “MAX/MIN” button
B5: “ALERT” button B6: “WEATHER“ button
B7: “+(12/24)” button B8: “- (°C/°F)” button
B9: “HOLD
” button B10: ”CHANNEL” button
B11: “RESET” button
Part C- Structure
C1: Wall Mount Hole C2:.Battery Compartment
C3: Stand
Thermo Sensor Unit Appearance.
D1: Outdoor Temperature D2: Transmission Indication LED
D3: “°C/°F” button D4: Channel Selecting Switch
D5: “TX” button D6: Wall Mount Hole
D7: Battery Compartment
Set Up:
Insert batteries.
Use a pin to press the RESET (B11) button
Radio Controlled Clock:
l
The clock automatically starts scanning the RF 433MHz signal to register new
Thermo Sensor Unit after new batteries inserted. After registered new channels or
press “CHANNEL” button (B10) to stop scanning, the clock will then scan the
DCF time signal ( “
” flashes on the LCD ). Buttons will not function while
scanning for DCF or Thermo sensor’s signal unless they are well received or
stopped manually.
l
The clock automatically scans the time signal at 3.00 a.m. everyday to maintain
accurate timing. For failed reception, scanning stops ( “
” on the LCD
disappear ) and repeats again at 4.00 a.m. 5.00a.m. and 6.00a.m.
l
The clock manually scans the DCF time signal by holding “ -
” button (B8) for
3 seconds. For failed reception, scanning stops. ( “
” on the LCD disappear ).
l
Press “HOLD
” button (B9) to stop scanning when receiving DCF time signal.
“
” flashes indicate now is receiving DCF time signal
“
” turns on indicate signal received successfully
Manual Time Setting:
l
Hold “MODE/SET” button (B1) for 3 seconds to enter Clock/Calendar setting
Mode .
l
Press “+” (B7) or “-” (B8) buttons to adjust the setting and press “MODE/SET”
button (B1) to confirm each setting.
l
The setting sequence is shown as follow: Hour, Minutes, Second, Year,
Month/Day sequence, Month, Day, Time Zone, Day-of-week language.
8 languages can be selected in Day-of-week, they are: German, English, Russian,
Denmark, Dutch, Italian Spanish and French,. The languages and their selected
abbreviations for each day of the week are shown in the following table.
Language
Sunday
Monday Tuesday Wednesday Thursday Friday Saturday
German, GE
SO
MO
DI
MI
DO
FR
SA
English, EN
SU
MO
TU
WE
TH
FR
SA
Russian, RU
BC
NH
BT
CP
HT
NT
CY
Denmark, DA SO
MA
TI
ON
TO
FR
LO
Dutch, NE
ZO
MA
DI
WO
DO
VR
ZA
Italian, IT
DO
LU
MA
ME
GI
VE
SA
Spanish, ES
DO
LU
MA
MI
JU
VI
SA
French, FR
DI
LU
MA
ME
JE
VE
SA
l
The zone is used for the countries where can receive the DCF signal but the time
zone is different from the German time.
l
When the country time is faster than the German time for 1 hr, the zone should be
set to 1. Then the clock will automatically set 1 hour faster from the signal time
received.
l
The Time Setting Mode will automatically exit in 5 seconds without any
adjustment.
l
“DST” is shown on the LCD if it is in Daylight Saving Time mode
12/24 Hour Display mode:
Press “+(12/24)” button (B7) to select 12 or 24 hours mode.
Snooze Alarm Clock Function:
l
Press “MODE/SET” button (B1) to select to view :
Time Date/Month /Weekday Alarm Time (“
“ Shown on the LCD)
l
When viewing the Alarm Time, hold “MODE/SET” button (B1) for 3 seconds to
enter Alarm Time setting. Press “ +” (B7) or “-” (B8) buttons to adjust the alarm
time.
l
Press “ALARM ON/OFF” button (B3) to switch alarm on or off. If it is on,
“
” shown on the LCD.
l
When Alarming, press “SNOOZE / LIGHT” button (B2) to activate the snooze
alarm. Snoozes alarm snoozes for 5 minutes, then it alarms again.
l
Press any button to stop the snooze alarm.
Weather Forecast Function:
l
After Batteries inserted, or holding “WEATHER” button (B6) for 3 seconds,
weather icon Flash (LCD-A1). Enter the current weather pressing “ + “ (B7) or “-
“ (B8) buttons. Press “MODE/SET” (B1) button to confirm the setting. The
weather forecast may not be accurate if the current weather entered is not correct.
l
Totally 5 different weather in the weather forecast.
“
” means Sunny .
“
” means Slightly Cloudy.
“
” means Cloudy.
“
” means Rainy
“
” means Cloudburst.
l
If there is any inconsistency of weather forecast between Local Weather Station
and this unit, the Local Weather Station's forecast should prevail. We will not held
responsible for any trouble that may come up due to wrong forecasting from this
unit.
l
The trend pointer displayed on the LCD indicates the trend of the Barometric
pressure.
“
” indicates the barometric pressure trend is increasing.
“
” indicates the barometric pressure trend is steady.