Tektronix TCA-292MM Instructions

Specifications

Brand: Tektronix
Category: Adapter
Model: TCA-292MM (Instructions)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Tektronix TCA-292MM Instructions online using the built-in PDF viewer.

Text of the manual

To avoid potential hazards, use this product only

as specified. To avoid fire or personal injury Connect and disconnect properly. Connect the adapter to the host instrument before connecting the 2.92 mm or SMA device to the device-undertest. Disconnect the device input and ground from the device-under-test before disconnecting the 2.92 mm or SMA device from the adapter and host instrument. Ground the product. This product is indirectly grounded through the grounding conductor of the host instrument power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded. Observe all terminal ratings. To avoid fire or shock hazard, observe all ratings and markings on the host instrument. Consult the host instrument documentation for further ratings information before making connections to the host instrument. Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal. Do not operate without covers. Do not operate this product with covers or panels removed. Do not operate with suspected failures. If you suspect there is damage to this product, have it inspected by qualified service personnel. Do not operate in wet/damp conditions. Do not operate in an explosive atmosphere. Keep product surfaces clean and dry. Safety symbols on the product Product Description The TekConnect-292MM adapter allows you to connect 2.92 mm and SMA-terminated devices to Tektronix instruments with the TekConnect interface. The adapter preserves maximum signal integrity and eliminates the need for additional external adapters, which can degrade voltage standing wave ratio (VSWR). Figure 1: TCA-292MM Adapter Using the Adapter The adapter connects directly to the TekConnect interface on the host instrument. Installing the Adapter 1. Insert the adapter into the TekConnect interface on the host instrument until the adapter locks in place. 2. Finger-tighten the screw to secure the adapter to the instrument. 3. Connect a 2.92 mm or SMA cable to the adapter. 4. Connect the other end of the 2.92 mm or SMA cable to the device under test. Removing the Adapter 1. Disconnect the 2.92 mm or SMA cable from the device under test. 2. Disconnect the 2.92 mm or SMA cable from the adapter. 3. Unscrew the screw that holds the adapter in place. 4. Press the button on top of the adapter to release the lock and remove the adapter from the host instrument. (See Figure 2.) NOTE. It may be necessary to remove the adapter before installing the host instrument cover. Figure 2: Removing the adapter from the host instrument CAUTION. Electrostatic discharge (ESD) can damage the instrument input. Use antistatic precautions when using this adapter. Specifications Maximum Input Voltage. The lesser of 30 VRMS or the maximum input voltage rating for the TekConnect host instrument. VSWR. Refer to the TekConnect host instrument for the overall system VSWR. Propagation Delay. 142 ps ±4 ps. Additional Information For additional information on using the TekConnect adapters, refer to the documentation for the host instrument. Warranty Information For warranty information, go to www.tektronix.com, click Support, and then select Look Up Tektronix Warranty. Contacting Tektronix Tektronix, Inc. 14200 SW Karl Braun Drive PO Box 500 Beaverton, OR 97077 USA For product information, sales, service, and technical support: In North America, call 1–800–833–9200. Worldwide, visit www.tektronix.com to find contacts in your area. *P071206401* 071-2064-01

Other Adapter Manuals