The operating manual describes the operating principle, op-

erational and maintenance conditions pertaining to module As- tra-PSTN (hereinafter referred to as “module”) (Fig.1). The manufacturer reserves the right to introduce changes which update and retrofit the device without prior notice. All such changes will be described in an updated revision of the operating manual. 1 Function 1.1 The module operates as a part of “Astra”-type devices which can house it (Astra-812М or Astra-Z-812М control pa- nels, hereinafter referred to as “control panel”). 1.2 The module operates in the two-wire public switched tel- ephone network and sends voice, tone or digital messages (in Contact ID, SIA FSK format). Note – In Astra-Zitadel system, the module sends digital mes- sages only. 1.3 The module is intended for continuous 24h use. 2 Specifications Power supply voltage, V ............................................ 3.3 ± 0.1 Current consumption, mA, max .......................................... 100 Communication line ...................... standard two-wire telephone Overall dimensions, mm, max .............................. 65  28  11 Weight, kg, max .................................................................. 0.02 Operating Conditions Temperature range, оС ................................ from -10 up to +55 Relative air humidity, ................................. up to 93 at + 40 C no moisture condensation 3 Delivery Set Astra-PSTN module.......................................................... 1 pcs. Operating manual ........................................................... 1 copy. 4 Structure Structurally, the module is comprised of the printed circuit board with radio elements (Fig. 1). Fig. 1 5 Module Installation 5.1 If shipping conditions differ from operating conditions, unpack the detector and wait for at least 4 hours before instal- ling it. 5.2 Only personnel familiarized with the operating manual and cleared to operate electric equipment of up to 1000V are allowed to mount, service and operate the module. 5.3 Installation Procedure 1) Switch off the control panel power supply. 2) Open the control panel cover by unscrewing two screws from the front side of the base. 3) Remove the keyboard printed circuit board by unscrew- ing four mounting screws. 4) Remove the keyboard fixing plank by unscrewing two mounting screws. 5) Install the module; the module shall be positioned in ac- cordance with marks (triangles), printed on PCBs of the mod- ule and the control panel. 6) Pull the telephone wire though the telephone wire hole, providing for hidden wire layout. Wiring to the control panel terminals shall be carried out is accordance with item 7. Plugs Printed cir- cuit board Marking for correct positioning during the installation into the control panel Back view Base PCB PSTN module Telephone wire hole

*Available at www.controlex.eu

Rev. PSTN-v1_3_en 7) Place the keyboard fixing plank and the keyboard PCB back into their positions. WARNING! If the keyboard bus line got disconnected from the socket, reconnect it in strict accordance with markings, printed on the bus line and the socket. 8) Close the control panel cover by screwing two screws into the front side of the base. 6 Module Setting 6.1 Module Registration Module registration is required in the Astra-Zitadel system on- ly. It is not required to register the module in the Observer I system. The module is registered after the installation in accordance with guidelines given in the operating manual for the Astra- Zitadel system*. 6.2 Module Setting The module is set from the PC using a corresponding setting program Pconf* in accordance with guidelines given in the op- erating manual for the selected system. WARNING! 1) When entering a recipient’s number, do not forget to enter a special symbol – “W” - waiting for the ringing tone in the line – after “9” for local calls or “8” for international calls (e.g., 9W8W432789598). 2) If the recipient’s number has an extension number, enter a special symbol – “B” - waiting for silence in the line after the main number is dialed (e.g., 2789598B183). 3) The module might not work with some mini ATX or national (international) numbers. 7 Connecting the Module to the Telephone Line 7.1 The control panel PCB is equipped with screw terminals; they are used to connect the telephone line and fixed tele- phone equipment. It is not necessary to observe proper polari- ty when connecting to the terminals! Terminal functions are given in Table 1. Table 1 Terminal Function Terminals are used when the module is in- stalled in the Socket А slot of the control panel. In the Astra-Zitadel system: SA1 - to connect the telephone line; SA2 - to connect a telephone set (fax). In the Observer I system: SA1 - to connect a telephone set (fax); SA2 - to connect the telephone line Terminals are used when the module is in- stalled in the Socket B slot of the control panel and only in the Astra-Zitadel system. SB1 - to connect the telephone line 7.2 Enter the engineer menu of the control panel using the engineer’s password and include the module in data ex- change with the control panel. 8 Remote Control Using the Module Objects can be remotely controlled using the PSTN module in the Observer I system only. Remote control is carried out in accordance with guidelines given in the operating manual for the Observer I system*. 9 Labeling The label glued to the module PCB contains the bar code with the following information: - module name or abbreviated designation; - firmware version; - month and year of manufacture (last two digits). 10 EC Conformity Declarations This product is in conformity with the provisions of: LVD 73/23/EEC+93/68/EEC EMC 89/336/EEC EN 61000-6-3:2005 Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments. EN 50130-4:1995 + A1:1998 + A2:2003 + Corrig. 2003 Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems. EN 60950-1: 2001+A11:2004+Corrig.2004 Safety of informa- tion technology equipment. 11 Recycling The module does not pose any life or health risk to individuals or to the environment. Once its service life is complete, the module may be utilized with no special environment protection measures. 12 Manufacturer Warranties 12.1 The manufacturer warrants that the module will meet re- quirements of technical specifications if a user follows all ship- ping, storage, mounting and operating guidelines. 12.2 Guaranteed storage life – 5 years and 6 months from the manufacture date. 12.3 Guaranteed service life – 5 years from the commission- ing, but not more than 5 years and 6 months from the manu- facture date. 12.4 The manufacturer shall repair or replace a faulty module during the warranty period. 12.5 The warranty becomes void if: – the user does not follow guidelines of the operating manual; – the module is mechanically damaged; – the module is repaired by a party other than the Manufacturer. 12.6 The warranty covers the module only. All equipment manufactured by other parties and used with the module is covered by its respective warranty. The manufacturer shall not be responsible for personnel death, injury, and damage to equipment or other acciden- tal or deliberate losses based on user’s claims that the module failed to function properly. Sales: Controlex GmbH Warranty service and technical support: ТЕКО-TD Philosophenweg 31-33 47051 Duisburg, Germany Phone: +49 (0) 203 / 393 91 188 Fax: +49 (0) 203 / 393 91 189 GSM: +49 (0) 178 / 218 48 22 E-mail: [email protected] Web: www.controlex.eu Prospect Pobedy str. 19 420138 Kazan, Russia Phone: +7 (843) 261-55-75 Fax: +7 (843) 261-58-08 E-mail: [email protected] [email protected] Web: www.teko.biz Made in Russia

Other Control Unit Manuals