TSP-5314 / TSP-5324 / TSP-5208
INSTALLATION AND PROGRAMMING MANUAL
V1.2
Revision Date: 26.12.2019
PARS SERIES
Intruder Alarm System
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
1 / 81
1. TABLE OF CONTENTS
1.
TABLE OF CONTENTS .................................................................................................................................... 1
2.
LIST OF FIGURES ............................................................................................................................................ 3
3.
IMPORTANT WARNINGS .............................................................................................................................. 4
4.
INTRODUCTION .............................................................................................................................................. 5
5.
SYSTEM FEATURES ....................................................................................................................................... 7
6.
INSTALLATION ............................................................................................................................................... 9
6.1
GENERAL................................................................................................................................................................ 9
6.2
PANEL CONNECTION DIAGRAM .................................................................................................................... 10
6.3
OUTDOOR SIREN CONNECTION .................................................................................................................... 14
6.4
DEDECTOR CONNECTION ................................................................................................................................ 14
6.4.1
Connection Without Resistor ............................................................................................................... 14
6.4.2
End of Line Resistant Connection ........................................................................................................ 15
6.4.3
Zone Doubling ............................................................................................................................................ 16
6.5
KEYPAD CONNECTION ...................................................................................................................................... 16
6.6
COMMUNICATION MODULE CONNECTIONS .............................................................................................. 17
6.6.1
Telephone Line Connection (For TSP-5314 Panel) ......................................................................... 17
6.6.2
TXM-5270 PSTN Module Connection ................................................................................................. 18
6.6.3
TXM-5272 GSM-GPRS Module Connection (for TSP-5314 and TSP-5208) ............................ 18
6.7
PGM CONNECTION ............................................................................................................................................. 19
6.8
POWER CONNECTION ...................................................................................................................................... 20
7.
PROGRAMRAMMING .................................................................................................................................. 21
7.1
INTRODUCTION ................................................................................................................................................... 21
7.2
ENTERING-EXITING INSTALLER PROGRAM AND MASTER PROGRAM .............................................. 22
7.3
BASIC SETTINGS ................................................................................................................................................ 22
7.3.1
Time/Date Settings ................................................................................................................................. 22
7.3.2
Entrance Delays ........................................................................................................................................ 23
7.3.3
Exit Delays .................................................................................................................................................. 23
7.3.4
CMS Account No ........................................................................................................................................ 24
7.3.5
CMS Phone Number ................................................................................................................................. 24
7.3.6
User Phone Numbers .............................................................................................................................. 25
7.3.7
User Codes .................................................................................................................................................. 25
7.4
PANEL SETTINGS ............................................................................................................................................... 26
7.4.1
General Settings ....................................................................................................................................... 26
7.4.2
Siren Settings ............................................................................................................................................ 28
7.4.3
Auto Arm/Disarm ..................................................................................................................................... 28
7.4.4
PGM Settings ............................................................................................................................................. 30
7.4.5
Timer Settings ........................................................................................................................................... 32
7.4.6
Remote Access .......................................................................................................................................... 33
7.4.7
Panel Info .................................................................................................................................................... 33
7.5
ZONE SETTINGS ................................................................................................................................................. 34
7.5.1
Connection Type ....................................................................................................................................... 34
7.5.2
Partition ....................................................................................................................................................... 35
7.5.3
Zon Type ...................................................................................................................................................... 36
7.5.4
Extra Settings ............................................................................................................................................ 37
7.5.5
Response Time .......................................................................................................................................... 38
7.5.6
Zone Names ............................................................................................................................................... 39
7.6
KEYPAD SETTINGS ............................................................................................................................................ 39
7.6.1
Keypad Option ........................................................................................................................................... 39
7.6.2
Keypad Partitions .................................................................................................................................... 40
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
2 / 81
7.6.3
Keypad Customize ................................................................................................................................... 40
7.7
USER SETTINGS ................................................................................................................................................. 42
7.7.1
Start Time ................................................................................................................................................... 42
7.7.2
Finish Time ................................................................................................................................................. 43
7.7.3
User Days .................................................................................................................................................... 43
7.7.4
User Partitions ......................................................................................................................................... 44
7.7.5
User Keypads ............................................................................................................................................ 44
7.7.6
User Limitations........................................................................................................................................ 45
7.8
COMMUNICATOR SETTINGS .......................................................................................................................... 46
7.8.1
General Options ........................................................................................................................................ 46
7.8.2
Raport Masks ............................................................................................................................................. 50
7.9
MODULES ............................................................................................................................................................ 52
7.8.3
Remote Module ......................................................................................................................................... 52
7.10 LEARN AND CHANGE THE KEYPAD ADDRESS ........................................................................................... 53
8.
PROGRAMMING TABLE .............................................................................................................................. 54
9.
RETURN TO FACTORY SETTINGS ............................................................................................................. 61
9.1
RETURN CODES TO FACTORY SETTINGS ..................................................................................................... 61
9.2
RESETTING PANEL SETTINGS TO FACTORY SETTINGS ........................................................................... 61
10.
TESTS .......................................................................................................................................................... 63
10.1
CMS CALL TEST .................................................................................................................................................. 63
10.2
USER CALL TEST ............................................................................................................................................ 63
10.3
SİREN TESTİ .................................................................................................................................................... 63
10.4
PGM TEST ........................................................................................................................................................ 64
10.5
PGM CONTROL ............................................................................................................................................... 64
11.
APPLICATION ........................................................................................................................................... 64
11.1
FIRE DETECTOR CONNECTION WITH PGM OUTPUT ............................................................................... 64
11.2
FIRE SIREN CONNECTION WITH PGM OUTPUT ........................................................................................ 65
11.3
PARTITION ........................................................................................................................................................... 65
11.4
HAREKETSİZLİKTE OTOMATİK ALARM KURMA ........................................................................................ 66
11.5
ARM / DISARM WITH CALENDER ................................................................................................................. 67
11.6
HOME – AWAY ARMING .................................................................................................................................. 67
12.
REPORTS ....................................................................................................................................................68
13.
KEYPAD USAGE ..........................................................................................................................................71
13.1
STATUS LED INDICATORS ............................................................................................................................... 72
13.2 FUNCTION KEYS................................................................................................................................................. 72
13.3 PARTITIONS AND ARROW KEYS.................................................................................................................... 72
13.4
KEYPAD ............................................................................................................................................................ 73
13.5 KEYPAD NOTIFICATIONS ................................................................................................................................. 73
13.5.1
KEYPAD SOUND NOTIFICATIONS .......................................................................................................... 73
13.5.2 KEYPAD LED NOTIFICATIONS ................................................................................................................ 73
14.
FAQs ............................................................................................................................................................ 74
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
3 / 81
2. LIST OF FIGURES
Figure 1: Installation .......................................................................................................................................................... 9
Figure 2: TSP-5314 Alarm Control Panel Connections ......................................................................................... 10
Figure 3: TSP-5324 Alarm Control Panel Connections .......................................................................................... 11
Figure 4: TSP-5208 Alarm Control Panel Connections ......................................................................................... 12
Figure 5: TSP-5208 Alarm Control Panel Connections .......................................................................................... 13
Figure 6: External Siren Connection ........................................................................................................................... 14
Figure 7: Detector Connections .................................................................................................................................... 14
Figure 8: Single EOL Connection with Tamper ......................................................................................................... 15
Figure 9: Single EOL Connection ................................................................................................................................... 15
Figure 10: Double EOL Connection ............................................................................................................................... 15
Figure 11: Double EOL Connection with Tamper ...................................................................................................... 15
Figure 12: Double Zone Connection With and Without Tamper Connection .................................................. 16
Figure 13: Keypad Connection ....................................................................................................................................... 17
Figure 14: Phone Line Connection ................................................................................................................................ 17
Figure 15: TSP-5324 and TSP-5208 Control Panel TXM-5270 Connection .................................................... 18
Figure 16: TSP-5314 and TSP-5208 Control Panel TXM-5272 Connection .................................................... 18
Figure 17: PGM ON – OFF Connection and Smoke Detector Connection .......................................................... 19
Figure 18: Main Connection ........................................................................................................................................... 20
Figure 19: Emergency Shortcut Keys .......................................................................................................................... 41
Figure 20: Remote Control Module Installation ..................................................................................................... 52
Figure 21: Reset Jumper .................................................................................................................................................. 62
Figure 22: PGM Connection for Smoke Detector .................................................................................................... 64
Figure 23: PGM Connection for Fire Siren ................................................................................................................. 65
Figure 24: TSK-5718 LED Keypad .................................................................................................................................. 71
Figure 25: TSK-5710 LCD Keypad .................................................................................................................................. 71
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
4 / 81
3. IMPORTANT WARNINGS
GENERAL :
Read these instructions carefully before operating the devices and keep it for future reference.
Observe all warnings and precautions specified in the instructions. Follow all operating instructions.
✓ Keep devices away from water and moisture.
✓ Mount this device to a solid surface to avoid damage to device or environment.
✓ Always use the device in its own box.
ENVIRONMENTAL CONDITIONS:
Do not operate the device in extremely hot or cold environments except under the following
conditions.
Temperature
: Between -20C ~ +70C
Humudity
: 0… %90rH
VENTILATION:
This device does not need ventilation.
POWER SUPPLY :
Only use the device with the voltage specified in these operating instructions. If you are not sure
about the supply voltage of the device, please contact your dealer or manufacturer.
GROUNDING AND POLING:
Make sure the grounding is connected properly before applying power. Make sure that the supply
voltage is correct.
POWER CABLE PROTECTION:
Protect the power cord from being crushed or broken.
POWER LINE :
Especially for external applications, supply a separate line from the power line of devices such as
lighting lamps or power circuits and keep them away from the line of other devices.
OVERLOAD :
To avoid the risk of electric shock or fire, do not connect device(s) that will draw extra current to
extension cords and sockets.
OBJECT AND LIQUID INPUT:
To avoid the risk of fire and electric shock, make sure that no liquid or other objects can enter the
control panel.
SERVICES :
Do not attempt to repair the appliance yourself, you may be exposed to electric shock if you open
the appliance door.
In the event of any malfunction, contact your dealer or authorized service. Technical intervention to
the device must be performed by qualified service personnel.
FAULT CONDITIONS REQUIRING SERVICE:
In the event of any malfunction or in the following cases, contact your authorized service or dealer.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
5 / 81
✓ When the power cord or plug is damaged
✓ When any liquid flows or any object falls into the device
✓ When exposed to water or rain
✓ If the device has been dropped or the housing has been damaged
✓ If the device has noticeable performance changes
✓ If the device does not operate normally according to the operating instructions, call for service
as improper operation may result in further malfunctions.
SPARE PART:
If the repair process will be done by replacing any parts; Make sure that the service technician uses
original or equivalent parts to avoid the risk of fire, electric shock, or other malfunction.
SECURITY CHECK:
Request service from your dealer to check that the device is operating in healthy, proper and safe
conditions.
TRANSPORTATION:
The device must be handled carefully so that it is not exposed to any external impact and does not
oppose the ingress of liquid. Malfunctions during improper handling are not covered by the
warranty.
HUMAN AND ENVIRONMENTAL HEALTH:
This device does not contain any chemical or biological substances that may harm human health.
WHAT YOU CAN DO ON YOURSELF:
Do not attempt to repair the appliance yourself, as you may be exposed to electric shock if you open
the device box. In the event of any malfunction, contact your dealer or authorized service. Technical
intervention to the device must be carried out by qualified service personnel. The device should be
cleaned with a dry cloth. Do not use any chemicals.
4. INTRODUCTION
Teknim Pars series alarm panels are user-friendly and capable of responding to many requests with
4+4 / 8+8 zone options and built-in PSTN / GSM-GPRS options. It’s offers easy of use for end users
and allows the installer to make easily commission the required features according to the user's
demand.
Easy Installation;
✓ Mount the Panel to wall with four holes, screws and dowels are in the box.
✓ Suitable for flush or surface mounting for easy cable entry.
✓ Function is written at each end of the terminal group. Connect all the cable of each devices
without mixing.
✓ Connect the telephone line.
✓ Plug the power supply socket.
Easy Maintenance;
✓ Current status, error-fault information is displayed, gives the necessary warnings instantly.
✓ Test functions allow you to test each component and hear the result audibly and visually.
✓ All events are stored in memory, can be easily viewed later.
✓ Uses a maintenance-free dry type battery.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
6 / 81
Easy Programming;
✓ The settings for each feature are grouped together. This makes your installation easier.
✓ The majority of the setting parameters must be multiple-choice.
✓ The panel can be commissioned by simply entering user passwords and phone numbers.
✓ All settings can be transferred from panel to computer or from computer to panel with PC
software and connection cable.
Easy Usage;
✓ Arm and Disarm by only Code.
✓ One-touch quick arm methods.
✓ Arm – Disarm by Keyfob.
✓ Arm – Disarm by Phone.
✓ Arm – Disarm by Key.
✓ Weekly programmable Arm – Disarm and Arm when no movement.
✓ Arm – Disarm by Mobile Application (TSP-5324 or with TXM-5272 Module)
Easy Automation;
✓ PGM outputs can be programmed weekly with associated timers.
✓ PGM outputs can be activated when there is movement in the associated zone or partition.
✓ PGM outputs can be enabled to be active when an alarm is set in the associated partition.
✓ PGM outputs can work like SRN in the associated partition.
✓ PGM outputs can be activated when fire is detected or reset fire detectors.
✓ PGM outputs can be remotely controlled by telephone.
✓ PGM outputs can be controlled by keypad.
✓ PGM outputs can be controlled by mobile application (TSP-5324 or With TXM-5272 Module)
Easy Management;
✓ Users codes canbe limit by date or entery-exit time.
✓ Users authorized partitions can be restricted.
✓ Keypads can be restricted for users.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
7 / 81
5. SYSTEM FEATURES
Inputs;
TSP-5314
TSP-5324
TSP-5208
Zone
4
4
8
Double Zone
Yes (8)
Yes (8)
Yes (8)
Zone Connection
NC-NO-Resistence Free
NC-NO-Resistence Free
NC-NO-Resistence Free
Keypad Zone
Var
Var
Var
Outputs;
TSP-5314
TSP-5324
TSP-5208
PGM Outputs
1 (NC-NO)
1 (NC-NO)
1 (NC-NO)
Siren Outputs
1
1
1
Siren Time
2-255 Sec
2-255 Sec
2-255 Sec
Electric – Mechanic;
TSP-5314
TSP-5324
TSP-5208
Power
230VAC 50Hz
230VAC 50Hz
230VAC 50Hz
Panel Fuse
125mA
125mA
125mA
Circuit Protection
Yes
Yes
Yes
Siren Out
500mA
500mA
500mA
AUX Out
750mA
750mA
750mA
PGM Out
500mA
500mA
500mA
Panel Voltage
12V
12V
12V
Output Current
1,5A
1,5A
1,5A
Dimentions
W: 260mm H: 300mm D:
39/95mm
G: 260mm Y: 300mm D:
39/95mm
G: 260mm Y: 300mm
D: 39/95mm
Weight
1690gr (Unpacked)
1980gr (Packed)
1690gr (Unpacked)
1980gr (Packed)
1690gr (Unpacked)
1980gr (Packed)
Keypad;
TSK-5710
TSK-5718
Keypad Support
4
4
Special Keys
Panic, Fire, Medical
Panic, Fire, Medical
LCD
Yes
No
LED
No
Yes
Keypad Backlit
Yes
Yes
LED Indicator
Yes
Yes
Event Memory
Yes
Yes
Chime
Yes
Yes
Dimensions
W: 171,5mm H: 120mm D: 20/36mm
W: 171,5mm H: 120mm D: 20/36mm
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
8 / 81
Usage Features;
✓ Passwords; 1x Master, 1x Engineering, 9x User, 1x Guest. All Four Digit
✓ 255 Event History (With Dates)
✓ 6 User Phone Number
✓ Two different ARC Support
✓ Two ARC number for Each ARC
✓ Manuel Bypass
✓ Configuration Software by PC
✓ 2 Weekly timer program
✓ Remotly controllable PGM by Mobile Application or Phone.
ARM and Disarm;
✓ Quick Arm,
✓ Partition Arm - Disarm,
✓ Home – Away Arming,
✓ Auto Arm - Disarm (Weekly Program) Arm When No Movement,
✓ Arm – Disarm by Key
✓ Arm – Disarm by Keyfob
✓ Arm – Disarm by Phone
✓ Arm – Disarm by Mobile Application (TSP-5324 or with TXM-5272 Module)
✓ Panic, Fire and Medical Alarm by Keypad
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
9 / 81
6. INSTALLATION
6.1
GENERAL
When you unpacked the control panel first time from the package you will find screw and EOL
Resistors inside which you can use for zone doubling.
After drilling holes in the wall with 8mm drill, the panel can be mounted on the concrete wall by
using screws. The panel box consists of two parts, the body and the lid. The four screws on the
cover can be removed with screwdriver.
Detectors, siren, keypad, telephone connections are made by using the appropriate cable. Make sure
all connections are correct before the mains connection. It is recommended to use LIYCY cable with
outer braided wire shield and foil and to connect the shields with a wire to the ground line at the
mains terminal.
It is also recommended to connect the shield on the keypad cable to the EGND (ground) on the panel
and keypad side. 3x0.75 mm² standard cable can be used for electrical mains connection.
Important: This device must be installed in a place free from dust and moisture. Suitable for indoor
installation.
WARNING: Do not energize the panel until the installation is completed and all connections are
correct.
Figure 1: Installation
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
10 / 81
6.2
PANEL CONNECTION DIAGRAM
Figure 2: TSP-5314 Alarm Control Panel Connections
Caution: Installation and electrical
connections of the panel must be
done
by
trained
personnel.
Unconscious
interventions
may
result
in
electrical
current
exposure and malfunctions of the
panel board.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
11 / 81
Figure 3: TSP-5324 Alarm Control Panel Connections
Caution: Installation and electrical
connections of the panel must be
done
by
trained
personnel.
Unconscious
interventions
may
result
in
electrical
current
exposure and malfunctions of the
panel board.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
12 / 81
Figure 4: TSP-5208 Alarm Control Panel Connections
Caution: Installation and electrical
connections of the panel must be
done
by
trained
personnel.
Unconscious
interventions
may
result
in
electrical
current
exposure and malfunctions of the
panel board.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
13 / 81
Figure 5: TSP-5208 Alarm Control Panel Connections
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
14 / 81
6.3
OUTDOOR SIREN CONNECTION
Sounder connection is made from 12V, SRN, GND terminals. 12V and GND are used to feed the siren.
This feed can be used for more than one siren. The siren trigger output of the panel is SRN.
Programmable as NO (Normally Open Contact) or NC (Normally Closed Contact).
Important: When two sirens are connected to the system, one of the sirens must be set to INT to
reduce the current drawn from the panel.
6.4 DEDECTOR CONNECTION
6.4.1 Connection Without Resistor
The terminals of the detectors are
basically relay contacts, and these
two terminals are connected to one
of the terminals Z1, Z2, ..., Zn. and
COM.
The detectors that require power are
supplied from the 12V + and -
terminals of the AUX terminal group.
Z1, Z2, ..., Zn zone inputs can be
programmed
as
input
activation
status NO or NC, end-of-line resistor
(single resistor, double resistor),
without resistor or double zone.
Figure 7 shows an example of connection of PIR detector, Smoke Detector, Gas Detector and
magnetic contact to the panel without end-of-line resistor connection type.
Figure 6: External Siren Connection
Figure 7: Detector Connections
VAS-740 Outdoor Siren
TSS-5790 Outdoor Siren
Detector Base
Detector Base
Smoke Detector
Gas Detector
Smoke Detector
Motion Detector
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
15 / 81
6.4.2 End of Line Resistant Connection
Using end-of-line resistance has advantages. When a single end-of-line resistor is used, a break in
the detector cable may be detected as sabotage by the panel. When a double end-of-line resistor is
used, both the detector cable break and the short circuit condition can be detected by the panel as
sabotage. Recommended to use double end-of-line resistor connection type.
The 2.7kΩ resistors from the panel packaging can be used for this purpose. These resistors must be
connected on the detector side. The connection of the resistors in the panel is incorrect because it
prevents the function from being performed. When more than one detector contact is connected in
series in the same Zone, end-of-line resistor connection cannot be made. Below are examples of
end-of-line resistance connections with and without tamper Connection.
Figure 9: Single EOL Connection
Figure 8: Single EOL Connection with Tamper
Figure 10: Double EOL Connection
Figure 11: Double EOL Connection with Tamper
Important: In order for the resistor connections to work properly, the resistors must be installed
on the detector side. Otherwise, the specified features will not work properly.
Motion Detector
Motion Detector
Motion Detector
Motion Detector
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
16 / 81
6.4.3 Zone Doubling
The number of zones can be increased with zone doubling. If 2KΩ and 3.9KΩ resistors are connected
to inputs Z1, Z2, ....., Zn as follows and programmed accordingly, zone doubling is performed at that
input. Thus, two zone connections are made, one being the connected input (Z1, Z2, ....., Zn) and the
other pair (Z9, Z10, ....., Z (n + 8)). The input reaction of all zones can be individually programmed as
NC or NO. Eamples of zone doubling is shown below. Zone doubling is not available when additional
zone modules are used. Below are examples of zone pairing with and without tamper.
PS: If a single end-of-line, double end-of-line resistor connection or zone doubling is made as
shown in the above figures, the system will alarm when the tamper is opened while the panel is
armed. If the panel is not armed, the system only warns of zone failure.
See section 7.5.1 Zone Connection Type for programming details.
6.5
KEYPAD CONNECTION
The keypad connection of the panel is made with 12V, A, B, GND terminals of keypad terminal group.
The 12V, A, B, GND terminals on the keypad should be connected to the same terminals on the panel
board. If there is a problem with the keypad connection, the keypad will warn you. It is
recommended to connect the shield on the keypad cable to the EGND on the panel and keypad sides.
4 keypads can be connected to TSP-5XXX panels. Keypad addresses must be given first when
connecting multiple keypads (To assign the keypad address, see section 7.10 Learning the Keypad
Address - Changing). In addition, the keypads must be activated in the program. (See section 7.6.1
Keypad Authorizations).
!!! WARNING: When connecting the keypad or replacing the keypad, make sure that the panel is
de-energized and terminals A, B do not come in contact with 12V. Otherwise, the panel may
malfunction.
Figure 12: Double Zone Connection With and Without Tamper Connection
Motion Detector
Motion Detector
Motion Detector
Motion Detector
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
17 / 81
IMPORTANT: The total length of the connecting cable between the keypad and the panel can be
up to 100 meters
Keypad Zone Connection;
6.6
COMMUNICATION MODULE CONNECTIONS
6.6.1 Telephone Line Connection (For TSP-5314 Panel)
The telephone line connection of the panel is made with LINE
terminal group. An internal or external line can be used in the
connection. If the line is disconnected, an error message is
displayed. Trouble and Memory lights flash on LED Keypad. The
Trouble light on the LCD Keypad turns on and the display shows
an error message. Error message disappears when panel
detects line. Also, a parallel device must not be connected to the
line at the LINE input. If there is a single telephone line and other
devices will use this line, the PTT line must be connected to the
LINE input and the line must be continued from PHONE output to
other devices (Telephone, Fax, POS machine, etc.).
PS: If the ADSL line is used, the telephone line connection of the panel must be made through the
phone line output of the SPLITTER device. Otherwise, the phone call feature of the panel may be
adversely affected.
Figure 13: Keypad Connection
Figure 14: Phone Line Connection
Phone Line
Figure 14: Keypad Zone Connection
MAG
GND
12V
A
B
GND
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
18 / 81
6.6.2 TXM-5270 PSTN Module Connection
The TXM-5270 PSTN Module is designed for the Alarm Panel to send information to users or the
Alarm Reciever Center over the telephone line. Can be used in TSP-5324 and TSP-5208 Alarm
Panels.
TXM-5270 The module is mounted to 4 screwing places in the space on the right side of the alarm
panel and the connection to the alarm panel board is made with the flat ribbon cable as in below
figure.
Ps: TSP-5314 PSTN line input is fixed on the alarm panel. Only TXM-5272 GSM / GPRS Module can be
added to this panel.
6.6.3 TXM-5272 GSM-GPRS Module Connection (for TSP-5314 and TSP-5208)
The TXM-5272 GSM-GPRS Module is designed for the Alarm Panel to send information to users or to
the Alarm Recieving Center via GSM or GPRS. Can be used in TSP-5314 and TSP-5208 Alarm Panels.
TXM-5272 The module is mounted to 4 screwing places in the space on the right side of the alarm
panel and the connection to the alarm panel board is made with the flat ribbon cable as in below
figure.
Ps: GSM / GPRS Module is fixed on TSP-5324 Alarm panel. Only TXM-5270 PSTN Module can be
added to this panel.
Figure 15: TSP-5324 and TSP-5208 Control Panel TXM-5270 Connection
Figure 16: TSP-5314 and TSP-5208 Control Panel TXM-5272 Connection
GSM
Antenna
GSM
Antenna
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
19 / 81
The TSP-5208 Alarm Panel can be connected to both TXM-5270 PSTN and TXM-5272 GSM / GPRS
Module simultaneously to back up communication. To do this, two modules should be mounted on
top of each other and cable connections should be made as shown above.
6.7
PGM CONNECTION
Teknim PARS series panels have 1 PGM output. This output can be used and programmed for a
variety of purposes, such as operating any device in the form of On - Off or resetting via the keypad
in case of smoke detectors connected to the system.
Attention should be paid to the current to be drawn from the PGM output, a relay with a contact
suitable for the load to be controlled should be used if the current does not exceed the maximum
PGM output current. (PGM 500mA, maks.)
Detailed information about programming can be found in 7.4.4 PGM Settings.
Figure 17: PGM ON – OFF Connection and Smoke Detector Connection
Detector Base
Smoke Detector
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
20 / 81
Figure 18: Main Connection
6.8 POWER CONNECTION
3x0,75 mm² standard cable can be used for main connection. Connection can be done in accordance
with the label on the mains terminal inside the panel.
Inside the panel there is 220V / 21V 25 V.A transformer. Cables from this transformer are plugged
into 24VAC socket. The LED on the board indicates that the panel is energized. 12V 7Ah battery can
be connected to the panel. The battery connection cables are mounted on the board. Red (+) and
Black (-) cables are connected to the battery by looking at the correct polarity colors. If there is no
mains connection during the first commissioning, if the system is to be operated on battery only, the
start button on the panel must be pressed for 3 seconds. When the system is powered by the
battery, the display and keypad lighting is reduced so that the panel consumes less energy.
Next to the mains connection terminal there is a glass fuse of 0.125A with handle in the housing. If
the fuse blows for any reason, it can be removed by pulling from the handle and replaced with a
new one.
PS: If the system is to be operated with
battery for the first time, press and hold the
Start button on the panel board for 3
seconds.
!!! IMPORTANT !!!
When the panel battery runs out and falls below 10.5V, the panel will be closed to protect itself and
the battery. Do not use batteries with a value below 10.5V on the load.
ACCORDING TO EN 60335-1 SAFETY RULES - HOME AND SIMILAR APPLICATIONS FOR ELECTRICAL
APPLIANCES grounding of the devices will increase EMC immunity and ensure better health in the
long run.
!!! Electrical accidents and problems with the general operation of the control panel may occur
after starting the device without connecting the ground. !!!
CAUTION: Make sure
that the grounding is
properly done
Battery
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
21 / 81
7. PROGRAMRAMMING
7.1
INTRODUCTION
Teknim PARS series panels have two programming sections.
“Installer Program” It provides access to the engineering settings of the system. Login with
engineering code.
“Master Program”
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
22 / 81
7.2
ENTERING-EXITING INSTALLER PROGRAM AND MASTER PROGRAM
To enter the engineering program, press [Fx] then [4], a long beep sounds and enter the engineer
password. The device enters the “Installer Program”. Program LED on LED Keypad, Ready light
flashes. LCD keypads display "INSTALLER MENU".
To enter the Installer Program;
Press [Fx] then Press [4] enter Installer Code (XXXX)
Factory Default of Installer Code is = 9999
To enter the master program, press [Fx] then [4], a long beep sounds and enter the master code. The
device enters the “Master Program”. Program LED on LED Keypad, Ready light flashes. LCD keypads
display "MASTER MENU".
To enter the Master Program;
Press [Fx] then Press [4] enter Master Code (XXXX)
Factory Default of Master Code is = 1234
To exit the program, hold down the X (Exit) key until a long beep sounds and the device returns to
normal. Program LED off.
PS: If no commands are sent to the panel within 3 minutes after programming, the panel
automatically exits the “Program” position and returns to normal.
7.3
BASIC SETTINGS
This is the section where the basic settings such as date - time, delay times and telephone numbers
are made.
7.3.1 Time/Date Settings
The Control Panel's Time and Date settings are made in this step, a panel without a time and date
setting turns on the Trouble LED and gives an error warning. Error settings are automatically
removed when these settings are made.
Setting the Time
• LED Keypad; [01] [01] → [HH: MM] → [√ OK]
• LCD Keypad; [Basic Settings √ OK] → [Time/Date Settings √ OK] → [HH: MM] → [√ OK]
eg. To set time 09:05 with LED Keypad; [01] [01] [09] [05] [√ OK]
Setting the Date
• LED Keypad; [01] [02] → [DD:MM:YY] → [√ OK]
• LCD Keypad; [Basic Settings √ OK] → [Time/Date Settings √ OK] → [DD:MM:YY] → [√ OK]
eg. To set date 10.11.2019 with LED Keypad; [01] [02] [10] [11] [19] [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
23 / 81
7.3.2 Entrance Delays
This is the delay time (second) for the user to disarm the system. Separate times can be defined for
each partition.
Entrance Delay for Partition A;
• LED Keypad; [02] [01] → [SS] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[1- Part Entrance Delay √ OK]→[SS]→[√ OK]
Entry Delay for Partition B;
• LED Keypad; [02] [02] → [SS] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[2- Part Entrance Delay √ OK]→[SS]→[√ OK]
Entry Delay for Partition C;
• LED Keypad; [02] [03] → [SS] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[3- Part Entrance Delay √ OK]→[SS]→[√ OK]
Entry Delay for Partition D;
• LED Keypad; [02] [04] → [SS] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[4- Part Entrance Delay √ OK]→[SS]→[√ OK]
eg. To set Entrance Delay for Partition A as 10sec. ; [02] [01] [10] [√ OK]
7.3.3 Exit Delays
This is the delay time (second) for the user to leave the place after arming the system. Separate
times can be defined for each partition.
Exit Delay for Partition A;
• LED Keypad; [03] [01] → [SS] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[1- Part Exit Delay √ OK]→[SS]→[√ OK]
Exit Delay for Partition B;
• LED Keypad; [03] [02] → [SS] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[2- Part Exit Delay √ OK]→[SS]→[√ OK]
Exit Delay for Partition C;
• LED Keypad; [03] [03] → [SS] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[3- Part Exit Delay √ OK]→[SS]→[√ OK]
Exit Delay for Partition D;
• LED Keypad; [03] [04] → [SS] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[4- Part Exit Delay √ OK]→[SS]→[√ OK]
Ör: To set Exit Delay for Partition A as 15sec. ; [03] [01] [15] [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
24 / 81
7.3.4 CMS Account No
If the system will send information to a Central Monitoring Station, the customer account number
specified by the CMS will set in this step. Two different CMS numbers can be assigned to the system.
Set 1st CMS Account NO
• LED Keypad; [04] [01] → [XXXX] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[CMS Accounts √ OK]→[1- CMS Account XXXX]→[√ OK]
Set 2nd CMS Account NO
• LED Keypad; [04] [02] → [XXXX] → [√ OK]
• LCD Keypad; [Basic Settings √ OK]→[CMS Accounts √ OK]→[2- CMS Account XXXX]→[√ OK]
eg. To set first CMS Account no as 1234; [04] [01] [1234] [√ OK]
Ps: IF CMS account number contains Hexadecimal code, (A, B, C, D, E, F) when entering account
number, press and hold;
[1] for A – [2] for B – [3] for C – [4] for D – [5] for E – [6] for F
7.3.5 CMS Phone Number
If the system will send information to a Central Monitoring Station, the CMS phone number will set
in this step. Two different CMS phone numbers can be assigned to the system as back up.
Set 1st CMS Phone Numer;
• LED Keypad; [05] [01] → [XXXXXXXXXXX] → [√ OK]
• LCD Keypad; [Basic Settings √ OK] → [CMS Phone √ OK] → [1. Phone No XXXXXXXXXXX] → [√ OK]
Set 2nd CMS Phone Numer;
• LED Keypad; [05] [02] → [XXXXXXXXXXX] → [√ OK]
• LCD Keypad; [Basic Settings √ OK] → [CMS Phone √ OK] → [2. Phone No XXXXXXXXXXX] → [√ OK]
Set 1st CMS Backup Phone Numer;
• LED Keypad; [05] [03] → [XXXXXXXXXXX] → [√ OK]
• LCD Keypad; [Basic Settings √ OK] → [CMS Phone √ OK] → [3. Phone No XXXXXXXXXXX] → [√ OK]
Set 2st CMS Backup Phone Numer;
• LED Keypad; [05] [04] → [XXXXXXXXXXX] → [√ OK]
• LCD Keypad; [Basic Settings √ OK] → [CMS Phone √ OK] → [4. Phone No XXXXXXXXXXX] → [√ OK]
eg. To set first CMS phone number as 02161234567; [05] [01] [02161234567] [√ OK]
PS: If the phone line provided from phone switchboard with specific number, you should enter
that number before entering the phone number and press long [0].
eg. [05] [01] [X] [0 Long] [02161234567] [√ OK]
PS2: To erase any CMS phone number, get to related address and press-hold [B] Key.
eg. [05] [01] [B Long] [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
25 / 81
7.3.6 User Phone Numbers
User phone numbers are entered in this step so that the alarm system can notify the end user. The
system can notify 6 phone numbers in total.
• LED Keypad;
1. User Phone Number: [06] [01] → [XXXXXXXXXXX] → [√ OK]
2. User Phone Number: [06] [02] → [XXXXXXXXXXX] → [√ OK]
3. User Phone Number: [06] [03] → [XXXXXXXXXXX] → [√ OK]
4. User Phone Number: [06] [04] → [XXXXXXXXXXX] → [√ OK]
5. User Phone Number: [06] [05] → [XXXXXXXXXXX] → [√ OK]
6. User Phone Number: [06] [06] → [XXXXXXXXXXX] → [√ OK]
• LCD Keypad;
[Basic Settings √ OK] → [User Phones √ OK] → [1- User No XXXXXXXXXXX] → [√ OK]
[Basic Settings √ OK] → [User Phones √ OK] → [2- User No XXXXXXXXXXX] → [√ OK]
[Basic Settings √ OK] → [User Phones √ OK] → [3- User No XXXXXXXXXXX] → [√ OK]
[Basic Settings √ OK] → [User Phones √ OK] → [4- User No XXXXXXXXXXX] → [√ OK]
[Basic Settings √ OK] → [User Phones √ OK] → [5- User No XXXXXXXXXXX] → [√ OK]
[Basic Settings √ OK] → [User Phones √ OK] → [6- User No XXXXXXXXXXX] → [√ OK]
eg. To set 1st user phone as 05321234567; [06] [01] [05321234567] [√ OK]
PS1: If the phone line provided from phone switchboard with specific number, you should enter
that number before entering the phone number and press long [0].
eg. [06] [01] [9] [0 uzun bas] [05321234567] [√ Tamam]
PS2: To erase any CMS phone number, get to related address and press-hold [B] Key.
eg. [06] [01] [B Long] [√ OK]
7.3.7 User Codes
By default no user code is defined in the control panel. In order to create a user code, you must
login with “Master Code” in “Master Menu”.
To Enter Master Menu;
• [Fx] → [4]
• Enter your Master Code (Factory Default: “1234”)
To create User Codes;
• LED Keypad;
1. User Code: [07] [01] → [XXXX] → [√ OK]
2. User Code: [07] [02] → [XXXX] → [√ OK]
3. User Code: [07] [03] → [XXXX] → [√ OK]
4. User Code: [07] [04] → [XXXX] → [√ OK]
5. User Code: [07] [05] → [XXXX] → [√ OK]
6. User Code: [07] [06] → [XXXX] → [√ OK]
7. User Code: [07] [07] → [XXXX] → [√ OK]
8. User Code: [07] [08] → [XXXX] → [√ OK]
9. User Code: [07] [09] → [XXXX] → [√ OK]
10. User Code: [07] [10] → [XXXX] → [√ OK]
11. Threat (Duress) Code: [07] [11] → [XXXX] → [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
26 / 81
• LCD Keypad;
[Basic Settings √ OK] → [User Codes √ OK] → [01-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [02-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [03-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [04-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [05-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [06-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [07-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [08-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [09-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [10-User Code XXXX] → [√ Ok]
[Basic Settings √ OK] → [User Codes √ OK] → [11-Threat (Duress) Code XXXX] → [√ Ok]
eg. To set 1st user code as 1111; [07] [1] [1111] [√ OK]
To set 2nd user code as 2222; [07] [2] [2222] [√ OK]
Master and Installer codes do not have an address. Master code factory default is “1234”, and
installer code factory default is “9999”. You can change these codes as follows.
• [√ Press and Hold] → [Enter Existing 4 Digit Code XXXX] → [New Code XXXX] → [Repeat New Code XXXX]
eg. To set Master code as 9876; [√ Hold] [1234] [9876] [9876]
To set Installer code as 4321; [√ Hold] [9999] [4321] [4321]
PS: The code changes for the LCD and LED Keypad are the same, and you do not need to press the
[√ OK] key at the end of the process.
PS 2: Threat Code only “Disarm” the system and send Alarm information to user phones and CMS
7.4
PANEL SETTINGS
This section contains the detailed settings of the control panel.
7.4.1 General Settings
General settings related to the panel.
Panel Options
Option
2.
3.
4.
5.
6.
Function
Quick Arm
Auto Siren Test
Arm – Disarm From
Different Keypad
Exit Delay
Extension
Double Hit
LED ON
ON
ON
ON
ON
ON
LED OFF
OFF
OFF
OFF
OFF
OFF
Quick Arm: When this option is active, you can use A – B – C – D keys to Quickly Arm the related
partition by press and hold the key.
Auto Siren Test: When this option is active, system gives warning with 2sec. siren sound when it’s
armed.
Arm – Disarm From Different Keypad: When this option is active, users can use the keypads that
are authorized in other partition. When it is off, the keypad cannot process any partition which is not
belong to.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
27 / 81
Exit Delay Extension: When this option is active; if any zone which programmed as input-output is
still active during exit delay, exit delay duration will automatically continue until the zone closed.
Double Hit: When this option is active, system gives alarm when the same zone gives 2x activation
during the cross zone time period which defined before. Double Hit function is only valid for the
zones which selected as cross zones.
• LED Keypad; [10] [01] → [2-3-4-5-6] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Panel Options 2-3-4-5-6] → [√ OK]
Output Polarization
PGM and SRN gives -12V. This option selecets if this outputs gives -12V when its activated or
passive.
Option
1.
4.
Function
PGM
SRN
LED ON
Active
Active
LED OFF
Passive
Passive
• LED Keypad; [10] [02] → [1-4] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Output Polar. 1-4] → [√ OK]
Default Settings Requests
You can choose the reset types in this section.
Option
1.
2.
Function
Reset Codes
Reset Panel Settings
LED ON
Active
Active
LED OFF
Passive
Passive
• LED Keypad; [10] [03] → [1-2] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Default Set. Req. 1-2] → [√ OK]
PS: You can only chose reset types in Installer Menu.
Reset Permission
You can give reset permission for each reset type.
Option
1.
2.
Function
Reset Codes Permission
Reset Panel Settings Permission
LED ON
Active
Active
LED OFF
Passive
Passive
• LED Keypad; [10] [04] → [1-2] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Reset Permission 1-2] → [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
28 / 81
Power Report Delay
In this section, you can set how many minutes after the power failure information will be notified to
the user and the CMS. A value can be entered between 0-60min.
• LED Keypad; [10] [05] → [DD] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Power Report Delay DD] → [√ OK]
Double Trigger Time
Double trigger time starts when one of the detectors with this feature is activated (to set this
feature to a detector see 7.5.4 Extra Settings). The first activation will not assign as an alarm. If
another zone which selected as cross zone or double trigger in the same partition activated in the
Double trigger time period, panel gives alarm and send the information to CMS or users.
If there will be no second activation after the first one, system gives “Cross Zone Fault”.
• LED Keypad; [10] [06] → [DD] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [General Settings √ OK] → [Double Trigger Time DD] → [√ OK]
7.4.2 Siren Settings
This is the section where the siren settings are made.
Siren Using Partitions
You can select which partitions are using siren.
• LED Keypad; [11] [01] → [1-2-3-4] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Siren Settings √ OK] → [Siren Settings Partitions A-B-C-D] → [√ OK]
Cut Off Time
You can select how many minute siren will work during alarm. Can be set between 2 – 255min.
• LED Keypad; [11] [02] → [DD] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Siren Settings √ OK] → [Cut Off Time DD] → [√ OK]
7.4.3 Auto Arm/Disarm
This is the section where the alarm system can be set up for any Partition to automatically arm and
disarm on certain days and times of the week.
Auto Arm Partitions
You can set which partitions will be Arm automatically.
• LED Keypad;
[12] [01] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[Auto Arm/Disarm √ OK]→[Auto Arm Partitions A-B-C-D]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
29 / 81
Auto Arm Days
You can set which days will be arm automatically.
• LED Keypad;
[12] [02] → [1234567] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[ Auto Arm/Disarm √ OK]→[ Auto Arm Days 1234567]→[√ OK]
PS: Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Auto Arm Time
You can set which time will be arm automatically.
• LED Keypad;
[12] [03] → [SS:DD] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[ Auto Arm/Disarm √ OK]→[ Auto Arm Time SS:DD]→ [√ OK]
Auto Disarm Partitions
You can set which partitions will be Disarm automatically.
• LED Keypad;
[12] [04] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[Auto Arm/Disarm √ OK]→[Auto Disarm Partitions A-B-C-D]→[√ OK]
Auto Disarm Days
You can set which days will be disarm automatically.
• LED Keypad;
[12] [05] → [1234567] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[ Auto Arm/Disarm √ OK]→[ Auto Disarm Days 1234567]→[√ OK]
PS: Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Auto Disarm Time
You can set which time will be disarm automatically.
• LED Keypad;
[12] [06] → [SS:DD] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[ Auto Arm/Disarm √ OK]→[ Auto Disarm Time SS:DD]→ [√ OK]
Inactivity Arm Partitions
You can set which partitions will be arm when there is no movement in it.
• LED Keypad;
[12] [07] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[ Auto Arm/Disarm √ OK]→[Inactivity Arm Partitions A-B-C-D]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
30 / 81
Inactivity Arm Delay
You can select the inactivity time in this section. System will be automatically armed if there will be
no movement in this time period. It can be set between 5 – 255min.
• LED Keypad;
[12] [08] → [DD] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[ Auto Arm/Disarm √ OK]→[ Inactivity Arm Delay DD]→ [√ OK]
7.4.4 PGM Settings
This section contains settings for using PGM. Each PGM has a usage type and a PGM parameter that
makes sense according to that usage type. In order for the PGM to function as required, both the
usage type and parameter must be set.
Use PGM 1 as
You can choose PGM types in this section.
No
Type
Parameter
Value
1
Manual
PGM can be use by manually. No need to set any value.
-
2
Zone Output
PGM activated when the selected zone is active. Values in the table are
entered in programming to determine which zone to activate.
To select multiple zones, the values
of the two zones are added.
eg. For Z3 and Z6, add both values
4+32= 36.
Zone
Value
Zone
Value
Z1
1
Z5
16
Z2
2
Z6
32
Z3
4
Z7
64
Z4
8
Z8
128
255
3
Partition Output
PGM activated when an alarm occurs in the
selected partition(s). To select the relevant
partition(s), the values in the table are added.
eg. For partition B and C, add and enter 2+4=6.
Partition
Value
A
1
B
2
C
4
D
8
15
4
ARM Status
PGM activated when the selected partition(s) is
armed. To select the relevant partition(s), the
values in the table are added.
eg. For partition B and C, add and enter 2+4=6.
Partition
Value
A
1
B
2
C
4
D
8
15
5
Firen Siren
PGM activated continuously when fire alarm occurs, no value is entered.
-
6
Fire Sensor
Power
When the fire detector supply is used via PGM, the reset time of the PGM
is entered with the password. Can be entered between 1-255 sec. You can
reset the fire detectors when it gives alarm by user codes.
10
7
Siren
PGM is used as a siren output for the selected
partition(s). To select the relevant partition(s), the
values in the table are added together and
entered.
eg. A ve C bölümleri için 1+4=5 değeri girilir.
Partition
Value
A
1
B
2
C
4
D
8
15
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
31 / 81
8
Trouble Output
PGM is active when selected
errors occur.
Fault
Value
Fault
Value
Mains
Fail
1
Phone
Line
Fail
8
Low
Battery
2
Zone
Fault
16
Time
Not Set
4
Battery
Fault
32
63
9
Access Control
Door lock open hold time can be entered in the range of 1-255 sec.
5
10
Timer Output
The PGM remains on for the specified time and then turns off. Can be
entered between 1-255 sec.
0
11
Random
PGM will open and close
randomly according to the
entered value.
Value
PGM ON
PGM OFF
0
1-255 sec.
1-255 sec.
1
1-255 min.
1-255 min.
2
1-63 sec.
1-255 sec.
3
1-63 min.
1-255 min.
0
12
Arm Indicator
When the alarm system is armed, PGM remains open for the entered
parameter value. Parameter can be entered between 0-255min.
0
13
Disarm Indicator
When the alarm system is disrmed, the PGM remains on until the entered
parameter value. Parameter can be entered between 0-255min.
0
14
Toggle RC Button
PGM activated by remote control. Parameter can be entered between 0-
255min.
0
15
Alarm Type
PGM is activated
according to the selected
alarm type.
Alarm Type
Value
Alarm Type
Value
Intruder
1
Duress
8
Panic
2
Tamper
16
Fire
4
Medical
32
63
• LED Keypad;
[13] [01] → [0-1-2-…-15] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[PGM Settings √ OK]→[User PGM 1 As {Select Value by (B) (C) Keys}]→[√ OK]
PGM Settings
PGM parameter varies according to the selected PGM type. The table above shows what this
parameter means and the setting options for each PGM type. If more than one option is selected, the
sum of the values corresponding to the options must be entered.
• LED Keypad;
[13] [02] → [XXX] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[PGM Settings √ OK]→[PGM Settings XXX]→[√ OK]
eg. If PGM is selected as Alarm type and is required to be active in Fire alarm and Medical alarm conditions;
The value specified for the fire alarm (4) and the value specified for the medical alarm (32) are added and the
value found (36) is entered. [13] [02] → [36] → [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
32 / 81
7.4.5 Timer Settings
In this section, you can program the PGM outputs are activated on the specified dates and times.
Timer 1 Settings
This setting determines whether the PGM is to be controlled with timer and whether the PGM output
is active or inactive at the specified time.
Option
1.
2.
Feature
PGM Use
PGM Active / Inactive
LED ON
Yes
Active
LED OFF
NO
Inactive
• LED Keypad; [14] [01] → [1-2] → [√ OK]
• LCD Keypad; [Panel Settings √ OK]→[Timer Settings √ OK]→[Timer 1 Settings 1-2] → [√ OK]
Timer 1 Days
This setting determines the days that PGM will be activated.
• LED Keypad; [14] [02] → [1234567] → [√ OK]
• LCD Keypad; [Panel Settings √ OK]→[Timer Settings √ OK] → [Timer 1 Days 1234567] → [√ OK]
PS: Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Timer 1 Time
This setting determines the time that PGM will be activated.
• LED Keypad; [14] [03] → [HH:MM] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Timer Settings √ OK] → [Timer 1 Time HH:MM] → [√ OK]
Timer 2 Settings
This setting determines whether the PGM is to be controlled with second timer and whether the
PGM output is active or inactive at the specified time.
Option
1.
2.
Feature
PGM Use
PGM Active / Inactive
LED ON
Yes
Active
LED OFF
NO
Inactive
• LED Keypad; [14] [04] → [1-2] → [√ OK]
• LCD Keypad; [Panel Settings √ OK]→[Timer Settings √ OK]→[Timer 2 Settings 1-2] → [√ OK]
Timer 2 Days
This setting determines the days that PGM will be activated.
• LED Keypad; [14] [05] → [1234567] → [√ OK]
• LCD Keypad; [Panel Settings √ OK]→[Timer Settings √ OK] → [Timer 2 Days 1234567] → [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
33 / 81
PS: Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Timer 2 Time
This setting determines the days that PGM will be activated.
• LED Keypad; [14] [06] → [HH:MM] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Timer Settings √ OK] → [Timer 2 Time HH:MM] → [√ OK]
7.4.6 Remote Access
This section contains settings for remote control of the alarm panel by phone and settings for usage
of the Cloud Communication.
Remote Control Settings
Use the option 1 to turn on or off remote alarm panel access by phone. And option 2 to open or close
the Cloud communication.
• LED Keypad; [15] [01] → [1-2] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Remote Access √ OK] → [Rem. Cont. Sett. 1-2] → [√ OK]
Ring Count
It determines ring numbers after control panel response by remote control with Phone.
• LED Keypad; [15] [02] → [X] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Remote Access √ OK] → [Ring Count Time X] → [√ OK]
7.4.7 Panel Info
This is where you can access basic information about the alarm panel. No settings can be made in
this section, only readable information.
Basic Informations are; Panel Type, Software Version, Hardware Version.
• LED Keypad;
[16] [01] → [Panel Type] → [√ OK]
[16] [02] → [SW Version] → [√ OK]
[16] [03] → [HW Version] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK] → [Panel Info √ Ok] → [Panel Type] → [√ OK]
[Panel Settings √ OK] → [Panel Info √ Ok] → [SW Version] → [√ OK]
[Panel Settings √ OK] → [Panel Info √ Ok] → [HW Version] → [√ OK]
Option
1.
2.
Feature
Access by Phone
Cloud Connection
LED ON
Yes
Active
LED OFF
NO
Passive
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
34 / 81
7.5
ZONE SETTINGS
This is the section where all settings related to zones are made.
7.5.1 Connection Type
The zone input must be set according to the connection type of the detector. The panel can be
adjusted according to the detector connections described in the installation section. Contact type
can be selected as NC (Normally Closed) or NO (Normally Open). Connection type can be selected
without resistance, single end resistance or double end resistance. Also unused zones can be turned
off in this section.
When double zone is activated for any zone from Zone 1 to Zone 8, the corresponding zone will be
activated. Which means if you activate double zone for Zone 1, the corresponding Zone 9 will be
activated. Below table, you can find the zone input settings;
Option
1.
2.
3.
4.
Feature
NC / NO
Single EOL Resistor
Double EOL Resistor
Zone Use / Not Use
LED ON
NC
Yes
Yes
In Use
LED OFF
NO
No
No
Not in Use
• LED Keypad;
Zone 1 - [20] [01] → [1-2-3-4] → [√ OK]
Zone 2 - [20] [02] → [1-2-3-4] → [√ OK]
Zone 3 - [20] [03] → [1-2-3-4] → [√ OK]
Zone 4 - [20] [04] → [1-2-3-4] → [√ OK]
Zone 5 - [20] [05] → [1-2-3-4] → [√ OK]
Zone 6 - [20] [06] → [1-2-3-4] → [√ OK]
Zone 7 - [20] [07] → [1-2-3-4] → [√ OK]
Zone 8 - [20] [08] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Zon Settings √ OK] → [Connection Type √ OK] → [1- Connection Type 1-2-3-4] → [√ OK]
[Zon Settings √ OK] → [Connection Type √ OK] → [2- Connection Type 1-2-3-4] → [√ OK]
[Zon Settings √ OK] → [Connection Type √ OK] → [3- Connection Type 1-2-3-4] → [√ OK]
[Zon Settings √ OK] → [Connection Type √ OK] → [4- Connection Type 1-2-3-4] → [√ OK]
[Zon Settings √ OK] → [Connection Type √ OK] → [5- Connection Type 1-2-3-4] → [√ OK]
[Zon Settings √ OK] → [Connection Type √ OK] → [6- Connection Type 1-2-3-4] → [√ OK]
[Zon Settings √ OK] → [Connection Type √ OK] → [7- Connection Type 1-2-3-4] → [√ OK]
[Zon Settings √ OK] → [Connection Type √ OK] → [8- Connection Type 1-2-3-4] → [√ OK]
PS 1: When a non-resistor connection is made, options 2 and 3 should be off.
PS 2: When zone doubling is made, both 2nd and 3rd options should be on.
PS 3: Zone doubling is not available on systems with additional zone cards.
Keypad Zone
Keypad zone connection is normally closed. If Keypad zone is to be used, this zone must be opened
in Connection Type settings.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
35 / 81
LCD Keypad;
[Zone Settings √ OK] →[ Connection Type √ OK] → [1- Keypad Connection Type 1-4] → [√ OK]
[Zone Settings √ OK] →[ Connection Type √ OK] → [2- Keypad Connection Type 1-4] → [√ OK]
[Zone Settings √ OK] →[ Connection Type √ OK] → [3- Keypad Connection Type 1-4] → [√ OK]
[Zone Settings √ OK] →[ Connection Type √ OK] → [4- Keypad Connection Type 1-4] → [√ OK]
PS 1: Keypad zone can also be used on LED Keypad, but programming of Keypad Zone cannot be
done with LED Keypad.
PS 2: When the Keypad Zone is activated, double zone feature for this zone is not available.
However, double zone of other zones can be used.
The keypad zones uses 29-30-31-32 zone numbers in the system. Keypad address determines the
connected zone number.
If the Keypad address is 01 then Keypad Zone number is 29
If the Keypad address is 02 then Keypad Zone number is 30
If the Keypad address is 03 then Keypad Zone number is 31
If the Keypad address is 04 then Keypad Zone number is 32.
To learn Keypad adress see the section 7.10 Learn and Change the Keypad Adress.
!!! Important !!!
It is recommended that the detector to be connected to the keypad zone does not require a 12V
supply such as a magnetic contact. If the detectors using external supply are connected and the 12V
supply requirement is met via the Keypad, the Keypad cable distance may need to be significantly
reduced. Otherwise, instability may occur in the operation of the keypad.
7.5.2 Partition
In this section, you can set each zones to assigned related partition. Each zone can be assigned to
only one partition. But you can add multiple zones to a single partition.
1. Option: Partition A , 2. Option: Partition B, 3. Option: Partition C, 4. Option: Partition D
• LED Keypad;
Zone 1 - [21] [01] → [1-2-3-4] → [√ OK]
Zone 2 - [21] [02] → [1-2-3-4] → [√ OK]
Zone 3 - [21] [03] → [1-2-3-4] → [√ OK]
Zone 4 - [21] [04] → [1-2-3-4] → [√ OK]
Zone 5 - [21] [05] → [1-2-3-4] → [√ OK]
Zone 6 - [21] [06] → [1-2-3-4] → [√ OK]
Zone 7 - [21] [07] → [1-2-3-4] → [√ OK]
Zone 8 - [21] [08] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Zone Settings √ OK] → [Partition √ OK] → [1- Zone Partition A-B-C-D] → [√ OK]
[Zone Settings √ OK] → [Partition √ OK] → [2- Zone Partition A-B-C-D] → [√ OK]
[Zone Settings √ OK] → [Partition √ OK] → [3- Zone Partition A-B-C-D] → [√ OK]
[Zone Settings √ OK] → [Partition √ OK] → [4- Zone Partition A-B-C-D] → [√ OK]
[Zone Settings √ OK] → [Partition √ OK] → [5- Zone Partition A-B-C-D] → [√ OK]
[Zone Settings √ OK] → [Partition √ OK] → [6- Zone Partition A-B-C-D] → [√ OK]
[Zone Settings √ OK] → [Partition √ OK] → [7- Zone Partition A-B-C-D] → [√ OK]
[Zone Settings √ OK] → [Partition √ OK] → [8- Zone Partition A-B-C-D] → [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
36 / 81
7.5.3 Zon Type
The zone type can be selected according to the type of zone and the location which detector
installed. The information which will be send to CMS will be defined in this section according to zone
type. Only one of these types can be selected for a zone.
Zone types are listed in the table below.
Option
Zone Type
Explanation
1
Door
This option is available for zones to which door-mounted magnetic
contacts are connected.
2
Window
This option is available for zones with window-mounted magnetic
contacts.
3
Interior
This option is available for zones with indoor sensors.
4
Exterior
This option is available for zones with outdoor sensors.
5
24 Hour
This type of selected zones are continuously active whether the system is
armed or not. Sends 24 Hour alarm information to CMS.
6
Fire
This type of selected zones are continuously active whether the system is
armed or not. Sends Fire Alarm information to CMS. Can be used the zones
which connected fire detector. Fire alarm can be silenced by entering code
on keypad.
7
Panic
Button
This type of selected zones are continuously active whether the system is
armed or not. Sends Panic alarm information to CMS. Can be use for Panic
buttons. Siren will not gives warning for this zone type.
8
Duress
This type of selected zones are continuously active whether the system is
armed or not. Sends Duress information to CMS. Siren will not gives
warning for this zone type.
9
Tamper
This type of selected zones are continuously active whether the system is
armed or not. Sends Tamper information to CMS. This zone type can be
used for tamper connections of the PIR, siren, panel etc.
10
Medical
This type of selected zones are continuously active whether the system is
armed or not. Sends Medical Alarm information to CMS. This zone type can
be selected when an emergency button is install to the system for the
person who need for care.
11
Custom
This type of selected zones are continuously active whether the system is
armed or not. Sends any information to CMS which user selected.
12
Keyswitch
System will be Armed if this zone goes NC and Disarmed if goes NO.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
37 / 81
• LED Keypad;
Zone 1 - [22] [01] → [XX] → [√ OK]
Zone 2 - [22] [02] → [XX] → [√ OK]
Zone 3 - [22] [03] → [XX] → [√ OK]
Zone 4 - [22] [04] → [XX] → [√ OK]
Zone 5 - [22] [05] → [XX] → [√ OK]
Zone 6 - [22] [06] → [XX] → [√ OK]
Zone 7 - [22] [07] → [XX] → [√ OK]
Zone 8 - [22] [08] → [XX] → [√ OK]
• LCD Keypad;
[Zone Settings √ OK] → [Zone Type √ OK] → [1- Zone Type] → [√ OK]
[Zone Settings √ OK] → [Zone Type √ OK] → [2- Zone Type] → [√ OK]
[Zone Settings √ OK] → [Zone Type √ OK] → [3- Zone Type] → [√ OK]
[Zone Settings √ OK] → [Zone Type √ OK] → [4- Zone Type] → [√ OK]
[Zone Settings √ OK] → [Zone Type √ OK] → [5- Zone Type] → [√ OK]
[Zone Settings √ OK] → [Zone Type √ OK] → [6- Zone Type] → [√ OK]
[Zone Settings √ OK] → [Zone Type √ OK] → [7- Zone Type] → [√ OK]
[Zone Settings √ OK] → [Zone Type √ OK] → [8- Zone Type] → [√ OK]
7.5.4 Extra Settings
This is the section where settings for zone behavior are made.
Option
1.
2.
3.
4.
5.
6.
7.
LED ON
Last Door
Zone ON
Follower
Zone ON
Entry – Exit
Zone ON
Silent
Zone ON
Bypass Not
Allowed
Include Home
Arming
Cross
Zone ON
LED OFF
Last Door
Zone OFF
Follower
Zone OFF
Entry – Exit
Zone OFF
Silent
Zone Off
Bypass
Allowed
Not Include
Home Arming
Cross
Zone OFF
Last Door Zone; When exit from the zone selected as the last door, alarm system will armed
immidiatly without waiting for exit delay ends. Last Door selected zone is automatically set as
Input-Output Zone.
Follower Zone; This zone follows the Input- Output zone. If Input- output zone activated before
followe zone, the follower zone gives entry – exit delay. But if the follower zone activated before
input – output zone, it gives alarm instantly.
Input - Output Zone; It gives entry delay if the system already armed and waiting for disarm or
gives exit delay if the system will be armed and leave the pleace.
Silent Zone; This zone will not trigger any sounder but it send alarm information to CMS.
Bypass Allowed – Not Allowed ; It allowes the bypass key if related zone can be bypass or not.
Include Home Arming; If this option is selected for any zone, when the system armed with “Stay”
mode, this zones will not work. This feature is used when the users arming the system while they
still inside the place.
Cross Zone; If two or more triggers are triggered during the cross-zone detection period, the panel
switches to alarms if the zones selected as Cross-Zone. If double hit selected, this activation trigger
should be triggered same detector during the cross zone period. But if double hit is not selected,
second trigger should triggered from cross zone in the same partition. If there will be no second
trigger in the time period of cross zone, panel gives Cross Zone Fault.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
38 / 81
LED Keypad;
Zone 1 - [23] [01] → [1-2-3-4-5-6-7] → [√ OK]
Zone 2 - [23] [02] → [1-2-3-4-5-6-7] → [√ OK]
Zone 3 - [23] [03] → [1-2-3-4-5-6-7] → [√ OK]
Zone 4 - [23] [04] → [1-2-3-4-5-6-7] → [√ OK]
Zone 5 - [23] [05] → [1-2-3-4-5-6-7] → [√ OK]
Zone 6 - [23] [06] → [1-2-3-4-5-6-7] → [√ OK]
Zone 7 - [23] [07] → [1-2-3-4-5-6-7] → [√ OK]
Zone 8 - [23] [08] → [1-2-3-4-5-6-7] → [√ OK]
• LCD Keypad;
[Zone Settings √ OK]→[Extra Settings √ OK]→[1- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[2- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[3- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[4- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[5- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[6- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[7- Zone Options 1-2-3-4-5-6-7]→[√ OK]
[Zone Settings √ OK]→[Extra Settings √ OK]→[8- Zone Options 1-2-3-4-5-6-7]→[√ OK]
PS: (1) Options 2 and 3 cannot be activated at the same time in one zone.
(2) Cross Zone feature only applies to zones selected as Door, Window, Internal and External. It
is not recommended to use cross zone feature in Entry-Exit and Follower Zones.
7.5.5 Response Time
The panel does not detect contact motion as an alarm for less than the given time. This value can be
set between 2-255. Each number defines 30 milisecond increase. For example if this value entered
15, the response time will be 15x30ms= 450 milisecond.
• LED Keypad;
Zone 1 - [24] [01] → [XX] → [√ OK]
Zone 2 - [24] [02] → [XX] → [√ OK]
Zone 3 - [24] [03] → [XX] → [√ OK]
Zone 4 - [24] [04] → [XX] → [√ OK]
Zone 5 - [24] [05] → [XX] → [√ OK]
Zone 6 - [24] [06] → [XX] → [√ OK]
Zone 7 - [24] [07] → [XX] → [√ OK]
Zone 8 - [24] [08] → [XX] → [√ OK]
• LCD Keypad;
[Zone Settings √ OK]→[Response Time √ OK]→[1- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[2- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[3- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[4- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[5- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[6- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[7- Zone Delay XX]→[√ OK]
[Zone Settings √ OK]→[Response Time √ OK]→[8- Zone Delay XX]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
39 / 81
7.5.6 Zone Names
It is the setting used to display the zone names as desired on the keypad display. This feature is only
available with LCD Keypad.
• LCD Keypad;
[Zone Settings √ OK]→[Zone Names √ OK]→[1- Zone Name]→[√ OK]
[Zone Settings √ OK]→[Zone Names √ OK]→[2- Zone Name]→[√ OK]
[Zone Settings √ OK]→[Zone Names √ OK]→[3- Zone Name]→[√ OK]
[Zone Settings √ OK]→[Zone Names √ OK]→[4- Zone Name]→[√ OK]
[Zone Settings √ OK]→[Zone Names √ OK]→[5- Zone Name]→[√ OK]
[Zone Settings √ OK]→[Zone Names √ OK]→[6- Zone Name]→[√ OK]
[Zone Settings √ OK]→[Zone Names √ OK]→[7- Zone Name]→[√ OK]
[Zone Settings √ OK]→[Zone Names √ OK]→[8- Zone Name]→[√ OK]
Numeric alphabet on keypad can be used to enter zone names. The numerical
alphabet on the keypad is as shown on the left (Figure 19). Left-right arrow
keys can be used to move between letters and up-down arrow keys can be
used to switch between zones. Press 0 twice to insert a space between words
or delete a letter.
7.6
KEYPAD SETTINGS
This is the section where all the Keypad settings are made. Pars series Alarm control panels suppors
4 keypad connection at the same time. All settings should be made for all 4 keypads separately. All
keypads should be giving addressed first. For addressing the keypads; see 7.10 Learn and Change
the Keypad Address.
7.6.1 Keypad Option
You can select whether the keypad is authorized to control the following features.
Option
1.
2.
3.
4.
5.
6.
7.
Feature
Keypad
Use
Quick Arm
ARM
Permission
Disarm
Permission
Programming
Access
Control
Keypad
Tamper
LED ON
Yes
Yes
Yes
Yes
Yes
Yes
Yes
LED OFF
No
No
No
No
No
No
No
PS: If keypad tamper activated, system gives Tamper Alarm when the communication is lost
between Keypad and Control Panel.
Figure 20: Numeric Keypad
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
40 / 81
LED Keypad;
Keypad 1 - [30] [01] → [1-2-3-4-5-6-7] → [√ OK]
Keypad 2 - [30] [02] → [1-2-3-4-5-6-7] → [√ OK]
Keypad 3 - [30] [03] → [1-2-3-4-5-6-7] → [√ OK]
Keypad 4 - [30] [04] → [1-2-3-4-5-6-7] → [√ OK]
• LCD Keypad;
[Keypad Settings √ OK]→[Keypad Options √ OK]→[1- Keypad Option 1-2-3-4-5-6-7]→[√ OK]
[Keypad Settings √ OK]→[Keypad Options √ OK]→[2- Keypad Option 1-2-3-4-5-6-7]→[√ OK]
[Keypad Settings √ OK]→[Keypad Options √ OK]→[3- Keypad Option 1-2-3-4-5-6-7]→[√ OK]
[Keypad Settings √ OK]→[Keypad Options √ OK]→[4- Keypad Option 1-2-3-4-5-6-7]→[√ OK]
7.6.2 Keypad Partitions
You can select authorized partitions for each Keypad. Each keypad can be authorized for multiple
partition.
• LED Keypad;
Keypad 1 - [31] [01] → [1-2-3-4] → [√ OK]
Keypad 2 - [31] [02] → [1-2-3-4] → [√ OK]
Keypad 3 - [31] [03] → [1-2-3-4] → [√ OK]
Keypad 4 - [31] [04] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Keypad Settings √ OK]→[Keypad Partitions √ OK]→[1- Keypad Authr. Partitions A-B-C-D]→[√ OK]
[Keypad Settings √ OK]→[Keypad Partitions √ OK]→[2- Keypad Authr. Partitions A-B-C-D]→[√ OK]
[Keypad Settings √ OK]→[Keypad Partitions √ OK]→[3- Keypad Authr. Partitions A-B-C-D]→[√ OK]
[Keypad Settings √ OK]→[Keypad Partitions √ OK]→[4- Keypad Authr. Partitions A-B-C-D]→[√ OK]
7.6.3 Keypad Customize
In this section you can make some settings such as Keypad warning, special keys, language options
and Keypad screen customizations.
Chime ON
An audible warning can be set on Keypad when defined zone triggered when the system is not
armed. This feature can be set when this zone is activated or de-activated.
To turn on the chime feature when the zone is active;
• LED Keypad;
Zon 1-8 - [32] [01] → [1-2-3-4-5-6-7-8] → [√ OK]
Zon 9-16 - [32] [02] → [1-2-3-4-5-6-7-8] → [√ OK]
Zon 17-24 - [32] [03] → [1-2-3-4-5-6-7-8] → [√ OK]
Zon 25-32 - [32] [04] → [1-2-3-4-5-6-7-8] → [√ OK]
• LCD Keypad;
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[1- Chime ON 1-8 Zones 1-2-3-4-5-6-7-8]→[√ OK]
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[2- Chime ON 9-16 Zones 1-2-3-4-5-6-7-8]→[√ OK]
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[3- Chime ON 17-24 Zones 1-2-3-4-5-6-7-8]→[√ OK]
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[4- Chime ON 25-32 Zones 1-2-3-4-5-6-7-8]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
41 / 81
To turn on the chime feature when the zone is de-active;
• LED Keypad;
Zon 1-8 - [32] [05] → [1-2-3-4-5-6-7-8] → [√ OK]
Zon 9-16 - [32] [06] → [1-2-3-4-5-6-7-8] → [√ OK]
Zon 17-24 - [32] [07] → [1-2-3-4-5-6-7-8] → [√ OK]
Zon 25-32 - [32] [08] → [1-2-3-4-5-6-7-8] → [√ OK]
• LCD Keypad;
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[1- Chime OFF 1-8 Zones 1-2-3-4-5-6-7-8]→[√ OK]
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[1- Chime OFF 9-16 Zones 1-2-3-4-5-6-7-8]→[√ OK]
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[1- Chime OFF 17-24 Zones 1-2-3-4-5-6-7-8]→[√ OK]
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[1- Chime OFF 25-32 Zones 1-2-3-4-5-6-7-8]→[√ OK]
Zone Light
Defines keypad lights when zones are activated.
• LED Keypad;
Zon 1-8 - [32] [09] → [1-2-3-4-5-6-7-8] → [√ OK]
Zon 9-16 - [32] [10] → [1-2-3-4-5-6-7-8] → [√ OK]
• LCD Keypad;
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[09- Lights 1-8 Zones]→[√ OK]
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[10- Lights 9-16 Zones]→[√ OK]
Emergency Keys
There are shortcut keys on the keypad that can be manually created
for Panic, Fire and Medical alarms (Figure 20). Press and hold these
keys to activate. In this section, you can select whether the
emergency shortcut keys on the keypad are active or not. Also you
can choose if Keypad installation tamper switch will be active or not.
Option
1.
2.
3.
4.
Feature
Panic
Fire
Medical
Keypad Tamper
LED ON
Yes
Yes
Yes
Yes
LED OFF
NO
NO
NO
NO
• LED Keypad;
[32] [11] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[11- EMG Buttons 1-2-3-4]→[√ OK]
Sound Option
You can set the following sound options on Keypad.
Option
1.
2.
3.
4.
5.
6.
Feature
Entry/Exit
Armed
Alarm
Fault
Keytone
Operate
LED ON
Yes
Yes
Yes
Yes
Yes
Yes
LED OFF
NO
NO
NO
NO
NO
NO
LED Keypad;
[32] [012] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Keypad Settings √ OK]→[ Keypad Customize √ OK]→[12- Sound Option 1-2-3-4-5-6]→[√ OK]
Figure 19: Emergency Shortcut Keys
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
42 / 81
Language (Only LCD Keypad)
You can change the language on LCD Keypad. Supported languages are English and Turkish.
• LCD Keypad;
[Keypad Settings √ OK]→[ Keypad Customize √ OK]→[13- Language]→[√ OK]
Logo Line 1 (Only LCD Keypad)
The information that will appear on the LCD Keypad screen when idle can be entered in this field.
LCD display can be set in two lines. Keypad numeric keys (Figure: 19) and arrow keys can be used to
enter letters.
• LCD Keypad;
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[15- Logo Line 1]→[√ OK]
Logo Line 2 (Only LCD Keypad)
The information that will appear on the LCD Keypad screen when idle can be entered in this field.
LCD display can be set in two lines. Keypad numeric keys (Figure: 19) and arrow keys can be used to
enter letters.
• LCD Keypad;
•
[Keypad Settings √ OK]→[Keypad Customize √ OK]→[16- Logo Line 2]→[√ OK]
7.7
USER SETTINGS
This is the section where the user codes are create or changed. These settings are only accessible in
the “Master Menu” and can only be entered with the Master User Code.
7.7.1 Start Time
You can set which user codes will be start active in a specific time. You can enter Hour (HH) and
minute (MM).
• LED Keypad;
1. User - [40] [01] → [HH:MM] → [√ OK]
2. User - [40] [02] → [HH:MM] → [√ OK]
3. User - [40] [03] → [HH:MM] → [√ OK]
4. User - [40] [04] → [HH:MM] → [√ OK]
5. User - [40] [05] → [HH:MM] → [√ OK]
6. User - [40] [06] → [HH:MM] → [√ OK]
7. User - [40] [07] → [HH:MM] → [√ OK]
8. User - [40] [08] → [HH:MM] → [√ OK]
9. User - [40] [09] → [HH:MM] → [√ OK]
10. User - [40] [10] → [HH:MM] → [√ OK]
• LCD Keypad;
[User Settings √ OK]→[Start Time √ OK]→[1- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[2- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[3- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[4- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[5- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[6- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[7- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[8- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[9- Start Time HH:MM]→[√ OK]
[User Settings √ OK]→[Start Time √ OK]→[10- Start Time HH:MM]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
43 / 81
7.7.2 Finish Time
You can set which user codes will be passive in a specific time. You can enter Hour (HH) and minute
(MM).
• LED Keypad;
1. User - [41] [01] → [HH:MM] → [√ OK]
2. User - [41] [02] → [HH:MM] → [√ OK]
3. User - [41] [03] → [HH:MM] → [√ OK]
4. User - [41] [04] → [HH:MM] → [√ OK]
5. User - [41] [05] → [HH:MM] → [√ OK]
6. User - [41] [06] → [HH:MM] → [√ OK]
7. User - [41] [07] → [HH:MM] → [√ OK]
8. User - [41] [08] → [HH:MM] → [√ OK]
9. User - [41] [09] → [HH:MM] → [√ OK]
10. User - [41] [10] → [HH:MM] → [√ OK]
• LCD Keypad;
[User Settings √ OK]→[Finish Time √ OK]→[1- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[2- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[3- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[4- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[5- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[6- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[7- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[8- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[9- Finish Time HH:MM]→[√ OK]
[User Settings √ OK]→[Finish Time √ OK]→[10- Finish Time HH:MM]→[√ OK]
7.7.3 User Days
You can set which user codes will be start active in a specific day.
1: Monday, 2: Tuesday, 3: Wednesday, 4: Thursday 5: Friday, 6: Saturday, 7: Sunday
• LED Keypad;
1. User - [42] [01] → [1-2-3-4-5-6-7] → [√ OK]
2. User - [42] [02] → [1-2-3-4-5-6-7] → [√ OK]
3. User - [42] [03] → [1-2-3-4-5-6-7] → [√ OK]
4. User - [42] [04] → [1-2-3-4-5-6-7] → [√ OK]
5. User - [42] [05] → [1-2-3-4-5-6-7] → [√ OK]
6. User - [42] [06] → [1-2-3-4-5-6-7] → [√ OK]
7. User - [42] [07] → [1-2-3-4-5-6-7] → [√ OK]
8. User - [42] [08] → [1-2-3-4-5-6-7] → [√ OK]
9. User - [42] [09] → [1-2-3-4-5-6-7] → [√ OK]
10. User - [42] [10] → [1-2-3-4-5-6-7] → [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
44 / 81
• LCD Keypad;
[User Settings √ OK]→[Days √ OK]→[1- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[2- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[3- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[4- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[5- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[6- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[7- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[8- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[9- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
[User Settings √ OK]→[Days √ OK]→[10- Authorized Days 1-2-3-4-5-6-7]→[√ OK]
7.7.4 User Partitions
You can set which user codes will be authorized in which partition(s).
1. Option: Partition A, 2. Option: Partition B, 3. Option: Partition C, 4. Option: Partition D
• LED Keypad;
1. User - [43] [01] → [1-2-3-4] → [√ OK]
2. User - [43] [02] → [1-2-3-4] → [√ OK]
3. User - [43] [03] → [1-2-3-4] → [√ OK]
4. User - [43] [04] → [1-2-3-4] → [√ OK]
5. User - [43] [05] → [1-2-3-4] → [√ OK]
6. User - [43] [06] → [1-2-3-4] → [√ OK]
7. User - [43] [07] → [1-2-3-4] → [√ OK]
8. User - [43] [08] → [1-2-3-4] → [√ OK]
9. User - [43] [09] → [1-2-3-4] → [√ OK]
10. User - [43] [10] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[User Settings √ OK]→[Partitions √ OK]→[1- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[2- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[3- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[4- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[5- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[6- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[7- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[8- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[9- Authorized Partitions A-B-C-D]→[√ OK]
[User Settings √ OK]→[Partitions √ OK]→[10- Authorized Partitions A-B-C-D]→[√ OK]
7.7.5 User Keypads
You can set which user codes will be authorized in which Keypads.
1. Option: 1. Keypad, 2. Option: 2. Keypad, 3. Option: 3. Keypad, 4. Option: 4. Keypad
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
45 / 81
• LED Keypad;
1. User - [44] [01] → [Authorized Keypad 1-2-3-4] → [√ OK]
2. User - [44] [02] → [Authorized Keypad 1-2-3-4] → [√ OK]
3. User - [44] [03] → [Authorized Keypad 1-2-3-4] → [√ OK]
4. User - [44] [04] → [Authorized Keypad 1-2-3-4] → [√ OK]
5. User - [44] [05] → [Authorized Keypad 1-2-3-4] → [√ OK]
6. User - [44] [06] → [Authorized Keypad 1-2-3-4] → [√ OK]
7. User - [44] [07] → [Authorized Keypad 1-2-3-4] → [√ OK]
8. User - [44] [08] → [Authorized Keypad 1-2-3-4] → [√ OK]
9. User - [44] [09] → [Authorized Keypad 1-2-3-4] → [√ OK]
10. User - [44] [10] → [Authorized Keypad 1-2-3-4] → [√ OK]
• LCD Keypad;
[User Settings √ OK]→[Keypads √ OK]→[1- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[2- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[3- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[4- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[5- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[6- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[7- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[8- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[9- Authorized Keypad 1-2-3-4]→[√ OK]
[User Settings √ OK]→[Keypads √ OK]→[10- Authorized Keypad 1-2-3-4]→[√ OK]
7.7.6 User Limitations
This is the section where user codes are restricted.
Option
1.
2.
3.
4.
5.
Feature
Arm Limit
Disarm Limit
One Time Code
One Day Code
Bypass Limit
LED ON
Yes
Yes
Yes
Yes
Yes
LED OFF
NO
NO
NO
NO
NO
• LED Keypad;
1. User - [45] [01] → [1-2-3-4-5] → [√ OK]
2. User - [45] [02] → [1-2-3-4-5] → [√ OK]
3. User - [45] [03] → [1-2-3-4-5] → [√ OK]
4. User - [45] [04] → [1-2-3-4-5] → [√ OK]
5. User - [45] [05] → [1-2-3-4-5] → [√ OK]
6. User - [45] [06] → [1-2-3-4-5] → [√ OK]
7. User - [45] [07] → [1-2-3-4-5] → [√ OK]
8. User - [45] [08] → [1-2-3-4-5] → [√ OK]
9. User - [45] [09] → [1-2-3-4-5] → [√ OK]
10. User - [45] [10] → [1-2-3-4-5] → [√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
46 / 81
• LCD Keypad;
[User Settings √ OK]→[Limitations √ OK]→[1- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[2- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[3- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[4- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[5- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[6- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[7- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[8- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[9- Limitations 1-2-3-4-5]→[√ OK]
[User Settings √ OK]→[Limitations √ OK]→[10- Limitations 1-2-3-4-5]→[√ OK]
PS: Options 3 and 4 are available only for the guest user (User 10).
7.8
COMMUNICATOR SETTINGS
This is the section where the general settings of the device related to call, SMS and Central
Monitoring Center are made.
7.8.1 General Options
General Settings
This is the section where CMS dialing, user dialing and telephone calls are made in general settings.
• LED Keypad;
[50] [01] → [1-2-3-4-5-6-7-8] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Options √ OK]→[General Settings 1-2-3-4-5-6-7-8]→[√ OK]
Dial Attempts
The number of times the call will be tried is determined. A value can be selected between 1 and 15.
• LED Keypad;
[50] [02] → [XX] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Dial Attempts XX]→[√ OK]
Test Interval
This is where you set how often the test signal is sent to the CMS.
Important: It is recommended to set this time to 24 Hours to avoid high invoice amounts when
using a PSTN telephone line.
Option
1.
2.
3.
4.
5.
6.
7.
8.
Feature
CMS
Call
User
Call
SMS
Calls Cancel
When
Disarm
Siren Warning
When Line Cut
Confirmation
from Phone
End Calls on
First
Confirmation
Silence
Alarm on
Confirmation
LED ON
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
LED OFF
NO
NO
NO
NO
NO
NO
NO
NO
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
47 / 81
LED Keypad;
[50] [04] → [XX] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Test Interval XX]→[√ OK]
First Test Time
The first test time to be sent to the CMS is entered in this section.
• LED Keypad;
[50] [05] → [HH:MM] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[First Test At HH:MM]→[√ OK]
Call Delay
This section specifies how many seconds to delay during between two-number dialing. Value can be
entered 1-30sec.
• LED Keypad;
[50] [06] → [XX] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Call Delay XX]→[√ OK]
CMS 1 Format
CMS format can be selected as Contact ID or SIA.
0: Contact ID – 1: SIA
• LED Keypad;
[50] [07] → [0-1] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[CMS 1 Format]→[√ OK]
CMS 2 Format
CMS format can be selected as Contact ID or SIA.
0: Contact ID – 1: SIA
• LED Keypad;
[50] [08] → [0-1] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[CMS 2 Format]→[√ OK]
Partition A CMS
Which CMS to send the reports for Partition A is selected in this section.
1: CMS 1 – 2: CMS 2
• LED Keypad;
[50] [09] → [1-2] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Partition A CMS 1-2]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
48 / 81
Partition B CMS
Which CMS to send the reports for Partition B is selected in this section.
1: CMS 1 – 2: CMS 2
• LED Keypad;
[50] [10] → [1-2] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Partition B CMS 1-2]→[√ OK]
Partition C CMS
Which CMS to send the reports for Partition B is selected in this section.
1: CMS 1 – 2: CMS 2
• LED Keypad;
[50] [11] → [1-2] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Partition C CMS 1-2]→[√ OK]
Partition D CMS
Which CMS to send the reports for Partition D is selected in this section.
1: CMS 1 – 2: CMS 2
• LED Keypad;
[50] [12] → [1-2] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Partition D CMS 1-2]→[√ OK]
Partition A Phones
Which user phone numbers to call for Part A is selected from this section. The system can call a
total of 6 user numbers.
• LED Keypad;
[50] [13] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Part. A Phones 1-2-3-4-5-6]→[√ OK]
Partition B Phones
Which user phone numbers to call for Part B is selected from this section. The system can call a
total of 6 user numbers.
• LED Keypad;
[50] [14] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Part. B Phones 1-2-3-4-5-6]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
49 / 81
Partition C Phones
Which user phone numbers to call for Part C is selected from this section. The system can call a
total of 6 user numbers.
• LED Keypad;
[50] [15] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Part. C Phones 1-2-3-4-5-6]→[√ OK]
Partition D Phones
Which user phone numbers to call for Part D is selected from this section. The system can call a
total of 6 user numbers.
• LED Keypad;
[50] [16] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Part. D Phones 1-2-3-4-5-6]→[√ OK]
Partition A SMS
Which user phone numbers to send SMS for Part A is selected from this section. The system can
send SMS total of 6 user numbers.
• LED Keypad;
[50] [17] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Part. A SMS 1-2-3-4-5-6]→[√ OK]
Partition B SMS
Which user phone numbers to send SMS for Part B is selected from this section. The system can
send SMS total of 6 user numbers.
• LED Keypad;
[50] [18] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Part. B SMS 1-2-3-4-5-6]→[√ OK]
Partition C SMS
Which user phone numbers to send SMS for Part C is selected from this section. The system can
send SMS total of 6 user numbers.
• LED Keypad;
[50] [19] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Part. C SMS 1-2-3-4-5-6]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
50 / 81
Partition D SMS
Which user phone numbers to send SMS for Part D is selected from this section. The system can
send SMS total of 6 user numbers.
• LED Keypad;
[50] [20] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[General Settings √ OK]→[Part. D SMS 1-2-3-4-5-6]→[√ OK]
PS: SMS can be used with panels with onboard GSM/GPRS Module or externally installed TXM-5272
GSM/GPRS Module.
Important: In order to send SMS, the SIM card inserted in the device must have SMS sending
enabled. To avoid surprise billing amounts, it is important that you define an SMS package that is
used according to your SMS preferences.
7.8.2 Raport Masks
It is the section where the communication ways of the system are selected. The following table
provides the necessary settings for all event types.
Option
1.
2.
3.
4.
5.
6.
Feature
CMS
Notification
Phone
Notification
CMS
Restores
Phone Restores
SMS Notification
SMS Restores
LED ON
ON
ON
ON
ON
ON
ON
LED OFF
OFF
OFF
OFF
OFF
OFF
OFF
The following settings can be made for a total of 32 different event types registered in the system.
You can find information on what these event types are and at which addresses they are registered
in the “Event Types and Addresses” table below.
• LED Keypad;
[51] [01] → [1-2-3-4-5-6] → [√ OK]
• LCD Keypad;
[Communicator √ OK]→[Report Masks √ Tamam]→[01- Intruder Alarm 1-2-3-4-5-6]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
51 / 81
Event Types and Addresses;
No
Event Type
Adress
Factory Default
1
Intruder Alarm
[51] [01]
1-2-3-5-6
2
Panic Alarm
[51] [02]
1-2-3-5-6
3
Fire Alarm
[51] [03]
1-2-3-5-6
4
Duress Alarm
[51] [04]
1-2-3-5-6
5
Tamper Alarm
[51] [05]
1-2-3-5-6
6
Medical Alarm
[51] [06]
1-2-3-5-6
7
Duress Disarm
[51] [07]
1-2-3-5-6
8
Cancel Alarm
[51] [08]
1-3-5-6
9
Zone Trouble
[51] [09]
1-3-5-6
10
Mains Failed
[51] [10]
1-3-5-6
11
Intruder Verify
[51] [11]
1-3-5-6
12
Cross Fault
[51] [12]
1-3-5-6
13
Low Battery
[51] [13]
1-3-5-6
14
Line Fail
[51] [14]
1-3-5-6
15
Battery Fail
[51] [15]
1-3-5-6
16
COM Fail
[51] [16]
1-3-5-6
17
Special ARM/Disarm
[51] [17]
1-3-5-6
18
Disarm
[51] [18]
1-3-5-6
19
Bypassed
[51] [19]
1-3-5-6
20
Programm Begin
[51] [20]
1-3-5-6
21
Programm End
[51] [21]
1-3-5-6
22
Periodic Report
[51] [22]
1-3-5-6
23
Panel Restart
[51] [23]
1-3-5-6
24
Manual Test
[51] [24]
1-3-5-6
25
Disarm By Phone
[51] [25]
1-3-5-6
26
Disarm By PC
[51] [26]
1-3-5-6
27
Remote Connection
[51] [27]
1-3-5-6
28
Line Intervention
[51] [28]
1-3-5-6
29
PGM Opened
[51] [29]
1-3-5-6
30
Custom Event
[51] [30]
1-3-5-6
31
24 Hour Alarm
[51] [31]
1-2-3-5-6
32
Factory Default
[51] [32]
1-3-5-6
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
52 / 81
7.9
MODULES
This is the section where additional Modules settings are made. These settings are only accessible
in the “Master Programming” and can only be entered with the Master User Code.
7.8.3 Remote Module
In addition to the keypad, remote control keyfob can be added to the system to perform the
operations such as arm-disarm and performing PGM control. In order to introduce a remote control
keyfob to the system, a remote control module must be connected to the system (TSC-5716). This
remote control receiver module can be install into the Keypad.
Add Remote
User code is required for adding remote keyfob. İlgili adıma gelindiğinde 4-digit code is entered for
which user is required to define a remote control keyfob and ve 4 buttons on the keyfob are pressed
simultaneously for 2 seconds. When the keypad sounds OK, 4 keys are pressed simultaneously for 2
seconds again.
• LED Keypad;
[60] [01] → [User Code XXXX] → [Press 4 Buttons]→ [Press 4 Buttons Again]→ [√ OK]
• LCD Keypad;
[Modules √ OK]→[Remote Module √ OK]→[Add Remote]→[User Code XXXX]→[Press 4 Buttons]→
[Press 4 Buttons Again]→[√ OK]
Important*: Before assigning a remote control keyfob to a user, that user's password must be
generated. If no password is generated, an error message “ID User Unavailable” is received.
Important**: Only one remote keyfob can be assigned to each user. If an attempt is made to re-
assign a remote keyfonb to a user who has already been assigned a remote keyfob, the system
warns “ID Remote Available”.
Erase Remote
This is the section where the user remote keyfob is deleted. The remote keyfob for each user
appears as “Available” or “Unavailable“. To delete the remote control, select “Unavailable” in the
related section.
LED Keypad;
[61] [01] → [Chose] → [√ OK]
• LCD Keypad;
[Modules √ OK]→[Remote Module √ OK]→[Erase Remote]→[Select Unavailable]→[√ OK]
PS: Selection is may done with right and left arrow keys (B-C).
Figure 20: Remote Control Module Installation
Remote Control Module (TSC-5715),
can be install inside of TSK-5710
LCD and TSK-5718 LED Keypads as
in figüre.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
53 / 81
7.10 LEARN AND CHANGE THE KEYPAD ADDRESS
The factory default for the keypad address is 1. If multiple keypads are used in the system, their
addresses must be different.
To change the keypad's address, the following operation is performed while the keypad in the
normal position.
[Press and Hold 4] → [Enter Keypad Address X] → [√ OK]
(Keypad address may given as 1, 2, 3 and 4)
To see the address of the keypad, the following operation is performed while the keypad in the
normal position.
LCD Keypad;
[Press and Hold 6] → [Master Code XXXX] → [4- Keypad Address] → [√ OK] Shown Keypad Address.
LED Keypad;
[Press and Hold 6] → [Master Code XXXX] → [Press 4] Shown Keypad Address.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
54 / 81
8. PROGRAMMING TABLE
This table shows all the functions and the factory settings that can be made on the panel.
Installer Menu with Installer Code – Factory Default: 9999
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
55 / 81
10 03
Default Settings Requests
1. Option: Reset Codes
2. Option: Reset Panel Settings
-
InP & MaP
10 04
Reset Permission
1. Option: Reset Codes Permission
2. Option: Reset Panel Settings Permission
1 - 2
InP
10 05
Power Report Delay
0~60 Minutes
15
InP
10 06
Double Trigger Time
0-255 Second
Ps: If you enter “0” Cross Zone Feature will be Off.
60
InP
11 – SIREN SETTINGS
11 01
Siren Using Partitions
1. Option: Partition A
2. Option: Partition B
3. Option: Partition C
4. Option: Partition D
A- B- C- D
InP
11 02
Cut-Off Time
2~255 Minutes
3
InP
12 – AUTO ARM/DISARM
12 01
Auto Arm Partition
1. Option: Partition A
2. Option: Partition B
3. Option: Partition C
4. Option: Partition D
Auto Arming is Disabled if All Options are Off
Disable
InP
12 02
Auto Arm Days
1. Option: Monday
2. Option: Tuesday
3. Option: Wednesday
4. Option: Thursday
5. Option: Friday
6. Option: Saturday
7. Option: Sunday
All Selected
InP & MaP
12 03
Auto Arm Time
HH: MM HH: Hour, MM: Minute
00:00
InP & MaP
12 04
Auto Disarm Partition
1. Option: Partition A
2. Option: Partition B
3. Option: Partition C
4. Option: Partition D
Auto Arming is Disabled if All Options are Off
Disable
InP & MaP
12 05
Auto Disarm Days
1. Option: Monday
2. Option: Tuesday
3. Option: Wednesday
4. Option: Thursday
5. Option: Friday
6. Option: Saturday
7. Option: Sunday
All Selected
InP & MaP
12 06
Auto Disarm Time
HH: MM HH: Hour, MM: Minute
00:00
InP & MaP
12 07
Inactivity Arm Partitions
1. Option: Partition A
2. Option: Partition B
3. Option: Partition C
4. Option: Partition D
Auto Arming is Disabled if All Options are Off
Disable
InP
12 08
Inactivity Arm Delay
5~255 Minutes
30 Minutes
InP
13 – PGM SETTINGS
13 01
Use PGM As…
0: Manually
1: Zone Output
2: Partition Output
3: ARM Status
4: Fire Siren
5: Fire Sensor Power
6: Siren
7: Trouble Output
8: Access Control
9: Timer Output
10: Random
11: ARM Indicator
12: Disarm Indicator
13: Toggle RC Button
14: Alarm Type
0
InP
13 02
PGM Settings
0~255 Minute
0
InP
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
56 / 81
14 – TIMER SETTINGS
14 01
Timer 1 Settings
1. Option: Use PGM Timer YES/NO
2. Option: PGM Active / Passive
-
InP & MaP
14 02
Timer 1 Days
1. Option: Monday
2. Option: Tuesday
3. Option: Wednesday
4. Option: Thursday
5. Option: Friday
6. Option: Saturday
7. Option: Sunday
All Selected
InP & MaP
14 03
Timer 1 Time
HH: MM HH: Hour, MM: Minute
00:00
InP & MaP
14 04
Timer 2 Settings
1. Option: Use PGM Timer YES/NO
2. Option: PGM Active / Passive
-
InP & MaP
14 05
Timer 2 Days
1. Option: Monday
2. Option: Tuesday
3. Option: Wednesday
4. Option: Thursday
5. Option: Friday
6. Option: Saturday
7. Option: Sunday
All Selected
InP & MaP
14 06
Timer 2 Time
HH: MM HH: Hour, MM: Minute
00:00
InP & MaP
15 – REMOTE ACCESS
15 01
Remote Control Settings
1. Option: Remote Access by Phone ON/OFF
2. Option: Cloud Communication ON/OFF
OFF
OFF
InP
15 02
Ring Count
1~20 Times
5 Times
InP
16 – PANEL INFO
16 01
Panel Type
Only Read
TSP-5xxx
InP
16 02
Software Version
Only Read
0
InP
16 03
Hardware Version
Only Read
0
InP
2 – ZONE SETTINGS
20 – CONNECTION TYPE
20 01
20 02
20 03
20 04
20 05
20 06
20 07
20 08
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
01-Keypad Zone 29
02-Keypad Zone 30
03-Keypad Zone 31
04-Keypad Zone 32
1. Opt.: NC/NO
2. Opt.: Singl EOL, Double Zone On/Off*
3. Opt.: Double EOL, Double Zone On/Off*
4. Opt.: Zone Use In Use/Not In Use
2 and 3 should be Off in Resistance-Free Connection.
2 and 3 should be On in Double Zone Connection.
Z9...Z(nx2) No Zone Activation Required.
Double Zone is Not Available with Additional Zone Card.
Keypad Zone settings can only be done via LCD Keypad.
When the Keypad Zone is activated, the zone numbers
according to the Keypad address are assigned as follows;
Keypad 1: Zone 29
Keypad 2: Zone 30
Keypad 3: Zone 31
Keypad 4: Zone 32
1 – 4
1
InP
21 – PARTITION
21 01
21 02
21 03
21 04
21 05
21 06
21 07
21 08
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
01-Keypad Zone 29
02-Keypad Zone 30
03-Keypad Zone 31
04-Keypad Zone 32
1. Option: Partition A
2. Option: Partition B
3. Option: Partition C
4. Option: Partition D
A
InP
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
57 / 81
22 – ZONE TYPE
22 01
22 02
22 03
22 04
22 05
22 06
22 07
22 08
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
01-Keypad Zone 29
02-Keypad Zone 30
03-Keypad Zone 31
04-Keypad Zone 32
1: Door
2: Window
3: Interior
4: Exterior
5: 24 Hour
6: Fire
7: Panic Button
8: Duress
9: Tamper
10: Medical
11: Custom
12: Keyswitch
Z1: 1
Z2: 3
Z3: 3
Z4: 3
Z5: 3
Z6: 3
Z7: 3
Z8: 3
KZ1: 3
KZ2: 3
KZ3: 3
KZ4: 3
InP
23 – EXTRA SETTINGS
23 01
23 02
23 03
23 04
23 05
23 06
23 07
23 08
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
01-Keypad Zone 29
02-Keypad Zone 30
03-Keypad Zone 31
04-Keypad Zone 32
1. Option: Last Door Zone Enable/Disable
2. Option: Follower Zone Enable/Disable
3. Option: Entry-Exit Zone Enable/Disable
4. Option: Silent Zone Enable/Disable
5. Option: Manual Bypass Enable/Disable
6. Option: Include Home Arming Enable/Disable
7. Option: Cross Zone Enable/Disable
Z1: 3
Z2: 2
Z3: -
Z4: -
Z5: -
Z6: -
Z7: -
Z8: -
KZ1: -
KZ2: -
KZ3: -
KZ4: -
InP
24 – RESPONSE TIME
24 01
24 02
24 03
24 04
24 05
24 06
24 07
24 08
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
01-Keypad Zone 29
02-Keypad Zone 30
03-Keypad Zone 31
04-Keypad Zone 32
2~255
Calculated in multiples of 30 milliseconds
Response Time: Value x 30ms
15
(450ms)
InP
25 – ZONE NAMES – (ONLE LCD KEYPAD)
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
Z9 – Z16
01-Keypad Zone 29
02-Keypad Zone 30
03-Keypad Zone 31
04-Keypad Zone 32
Numeric Input.
Right Left Arrow Keys Scroll.
Press “0” key twice for deleting letters.
Door
2. Zone
3. Zone
4. Zone
5. Zone
6. Zone
7. Zone
8. Zone
9.- 16. Zone
29. Zone
30. Zone
31. Zone
32. Zone
InP
3 – KEYPAD SETTINGS
30 – KEYPAD OPTIONS
30 01
30 02
30 03
30 04
1. Keypad
2. Keypad
3. Keypad
4. Keypad
1. Option: Use Keypad Enable/Disable
2. Option: Quick Arm Enable/Disable
3. Option: Arm Permission Enable/Disable
4. Option: Disarm Permission Enable/Disable
5. Option: Programming Enable/Disable
6. Option: Access Control Enable/Disable
7. Option: Keypad Tamper Enable/Disable
1.Keypad
1-2-3-4-5
Others
2-3-4
InP
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
58 / 81
31 – KEYPAD PARTITIONS
31 01
31 02
31 03
31 04
1. Keypad
2. Keypad
3. Keypad
4. Keypad
1. Option: Partition A
2. Option: Partition B
3. Option: Partition C
4. Option: Partition D
A- B- C- D
InP
32 – KEYPAD CUSTOMIZE
32 01
32 02
32 03
32 04
32 05
32 06
32 07
32 08
32 09
32 10
32 11
32 12
32 13
32 15
32 16
Chime when zone Active 1-8
Chime when zone Active 9-16
Chime when zone Active 17-24
Chime when zone Active 25-32
Chime when zone Passive 1-8
Chime when zone Passive 9-16
Chime when zone Passive 17-24
Chime when zone Passive 25-32
Light - Zone 1-8
Light - Zone 9-16
Emergancy Buttons
Sound Option
Language (Only LCD)
Logo Line 1 (Only LCD)
Logo Line 2 (Only LCD)
Choose the Zones to Chime When Zone Active
Choose the Zones to Chime When Zone Passive
Emergency Buttons
1. Option: Panic
2. Option: Fire
3. Option: Medical
4. Option: Keypad Tamper
Sound Options
1. Option: Entry/Exit
2. Option: Armed
3. Option: Alarm
4. Option: Fault
5. Option: Key Tone
6. Option: Operate
Language
Turkish - English (Only LCD Keypad)
Logo Line 1. and 2.
Company Information (Only LCD Keypad)
All Zones Are
ON
All Zones Are
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Turkish
InP & MaP
4 – USER SETTINGS
40 – START TIME
40 01
40 02
40 03
40 04
40 05
40 06
40 07
40 08
40 09
40 10
1. User
2. User
3. User
4. User
5. User
6. User
7. User
8. User
9. User
10. User
HH: MM HH: Hour, MM: Minute
00:00
MaP
41 – FINISH TIME
41 01
41 02
41 03
41 04
41 05
41 06
41 07
41 08
41 09
41 10
1. User
2. User
3. User
4. User
5. User
6. User
7. User
8. User
9. User
10. User
HH: MM HH: Hour, MM: Minute
23:59
MaP
42 – USER DAYS
42 01
42 02
42 03
42 04
42 05
42 06
42 07
42 08
42 09
42 10
1. User
2. User
3. User
4. User
5. User
6. User
7. User
8. User
9. User
10. User
1. Option: Monday
2. Option: Tuesday
3. Option: Wednesday
4. Option: Thursday
5. Option: Friday
6. Option: Saturday
7. Option: Sunday
All Days are
Selected
MaP
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
59 / 81
43 – USER PARTITIONS
43 01
43 02
43 03
43 04
43 05
43 06
43 07
43 08
43 09
43 10
1. User
2. User
3. User
4. User
5. User
6. User
7. User
8. User
9. User
10. User
1. Option: Partition A
2. Option: Partition B
3. Option: Partition C
4. Option: Partition D
A- B- C- D
MaP
44 – USER KEYPADS
44 01
44 02
44 03
44 04
44 05
44 06
44 07
44 08
44 09
44 10
1. User
2. User
3. User
4. User
5. User
6. User
7. User
8. User
9. User
10. User
1. Option: 1. Keypad
2. Option: 1. Keypad
3. Option: 1. Keypad
4. Option: 1. Keypad
1- 2- 3- 4
MaP
45 – USER LIMITATIONS
45 01
45 02
45 03
45 04
45 05
45 06
45 07
45 08
45 09
45 10
1. User
2. User
3. User
4. User
5. User
6. User
7. User
8. User
9. User
10. User
1. Option: Arm Limit Yes/No
2. Option: Disarm Limit Yes/No
3. Option: One Time Code Yes/No
4. Option: One Day Code Yes/No
5. Option: Bypass Limitation Yes/No
3 and 4 are valid only for the guest user.
-
-
-
-
-
-
-
-
-
4
MaP
5 – COMMUNICATOR
50 – GENERAL OPTIONS
50 01
General Settings
1. Option: CMS Call Yes/No*
2. Option: User Call Yes/No **
3. Option: SMS Yes/No
4. Option: Call Cancel When Disarm Yes/No
5. Option: Siren Warning When No Line Yes/No
6. Option: Confirmation from Phone Yes/No
7. End Calls on First Confirmation
Yes/No
8. Silence Alarm on Confirmation Yes/No
(*) CMS Call Automatically Opens When Any Phone Number Is
Entered.
(**) User Call Opens Automatically When Any Phone Number
Is Entere.
4
InP
50 02
Dial Attempts
1~15 Times
3
InP
50 04
Test Interval
1~48 Hour
24
InP
50 05
First Test At
HH: MM HH: Hour, MM: Minute
00:00
InP
50 06
Inter Call Delay
1~30 Secon
3
InP
50 07
50 08
CMS 1 Format
CMS 2 Format
0: Contact ID
1: SIA
0
InP
50 09
50 10
50 11
50 12
Partition A CMS
Partition B CMS
Partition C CMS
Partition D CMS
1. Option: Send Report to CMS 1
2. Option: Send Report to CMS 2
1
InP
50 13
50 14
50 15
50 16
Partition A Calls
Partition B Calls
Partition C Calls
Partition D Calls
1. Option: 1. User Phone
2. Option: 2. User Phone
3. Option: 3. User Phone
4. Option: 4. User Phone
5. Option: 5. User Phone
6. Option: 6. User Phone
All Selected
InP
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
60 / 81
50 17
50 18
50 19
50 20
Partition A SMS
Partition B SMS
Partition C SMS
Partition D SMS
1. Option: 1. User Phone
2. Option: 2. User Phone
3. Option: 3. User Phone
4. Option: 4. User Phone
5. Option: 5. User Phone
6. Option: 6. User Phone
All Selected
InP
51 – REPORT MASKS
51 01
51 02
51 03
51 04
51 05
51 06
51 07
51 08
51 09
51 10
51 11
51 12
51 13
51 14
51 15
51 16
51 17
51 18
51 19
51 20
51 21
51 22
51 23
51 24
51 25
51 26
51 27
51 28
51 29
51 30
51 31
51 32
1. Intruder Alarm
2. Panic Alarm
3. Fire Alarm
4. Duress Alarm
5. Tamper Alarm
6. Medical Alarm
7. Duress Disarm
8. Cancel Alarm
9. Zone Trouble
10. Mains Failed
11. Intruder Verify
12. Cross Fault
13. Low Battery
14. Line Fail
15. Battery Fail
16. Com Fail
17. Special Arm/Disarm
18. Alarm Arm/Disarm
19. Bypassed
20. Prog. Begin
21. Prog. End
22. Periodic Report
23. Panel Restart
24. Manual Test
25. Disarm By Phone
26. Disarm By PC
27. Remote Connection
28. Module Fault
29. PGM Opened
30. Custom Event
31. 24 Hour Alarm
32. Factory Default
1. Option: Event to CMS
2. Option: Event to Phone
3. Option: Restore to CMS
4. Option: Restore to Phone
5. Option: Event to SMS
6. Option: Restore to SMS
(*) Com Fault is only recorded in memory
(**) 33 64 are restores
1-2-3-5-6
1-2-3-5-6
1-2-3-5-6
1-2-3-5-6
1-2-3-5-6
1-2-3-5-6
1-2-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-3-5-6
1-2-3-5-6
1-3-5-6
InP
6 – MODULES
60 – ADD REMOTE MODULE
60 01
ADD Remote
1-
Enter User Code
2-
Press 4 Buttons Same Time
3-
Press 4 Buttons Same Time Again
-
MaP
61 – ERASE REMOTE MODULE
61 01
61 02
61 03
61 04
61 05
61 06
61 07
61 08
61 09
61 10
61 11
User 1 Remote Erase
User 2 Remote Erase
User 3 Remote Erase
User 4 Remote Erase
User 5 Remote Erase
User 6 Remote Erase
User 7 Remote Erase
User 8 Remote Erase
User 9 Remote Erase
User 10 Remote Erase
Master Remote Erase
Choose “Unavailable” to Erase Remote Keyfon by Arrow Keys.
-
MaP
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
61 / 81
9. RETURN TO FACTORY SETTINGS
All user codes and panel configuration settings can be reset to factory settings. These operations
can be selected in two types, such as resetting passwords to factory settings and resetting panel
settings to factory settings.
The reset process consists of two steps. Reset Permission and Reset Process.
Reset Permission: You can choose which reset types can be process. Reset Permission can be
selected only in “Installer Menu” which you can enter with “Installer Code”. You can only perform the
reset types which selected in this section.
Reset Process: Reset is performed by selecting the related option. The following table shows reset
types.
Option
1.
2.
Feature
Reset Password
Reset Configuration Settings
LED ON
Yes
Yes
LED OFF
No
No
9.1
RETURN CODES TO FACTORY SETTINGS
First, “Reset Codes” option must be selected in the Installer Menu. If this permission is not turned on,
reset cannot be performed.
To enable the Reset Codes permission;
• [Fx] [4] → [Installer Code XXXX]
• LED Keypad;
[10] [04]→[Press 1 to give permission to Reset Codes]→[√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[General Settings √ OK]→[Reset Permission - Press 1 for Reset Codes
Permission]→[√ OK]
To Reset all the Codes to Factory Settings;
• LED Keypad;
[10] [03] → [Press 1 to reset all codes] → [√ Tamam]
• LCD Keypad;
[Panel Settings √ OK]→[General Settings √ OK]→[Def. Set. Req. Press 1 to Reset all codes]→[√ OK]
9.2
RESETTING PANEL SETTINGS TO FACTORY SETTINGS
First, “Reset Panel Settings” option must be selected in the Installer Menu. If this permission is not
turned on, reset cannot be performed.
Before resetting the panel settings, “Reset Jumper” on the panel board must be short-circuited.
See Figure 22.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
62 / 81
To enable Panel Reset permission;
• [Fx] [4]→[Installer Code XXXX]
• LED Keypad;
[10] [04]→[ Press 2 to give permission to Reset Panel Settings]→[√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[General Settings √ OK]→[Reset Permission - Press 2 for Reset Panel Settings
Permission]→[√ OK]
Şifreleri Fabrika Ayarlarına Döndürmek İçin;
• LED Keypad;
[10] [03] → [Press 2 to reset all Panel Settings] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[General Settings √ OK]→[Def. Set. Req. Press 2 to Reset all Panel Settings]→[√ OK]
Important: The RST jumper
connection on the panel must be
short-circuited to restore the Panel
Settings to the Factory Settings.
Figure 21: Reset Jumper
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
63 / 81
10. TESTS
This is where you can test some system settings.
Press [Fx] and [8] key to enter test menu and enter your 4-digit code.
PS: You should enter Installer Code or Master code to enter Test menu. Other user codes will not
work to enter this menu.
10.1 CMS CALL TEST
To test Central Monitoring Station reports proceed following process.
• LED Keypad;
[Fx] [8] → [Code XXXX] → [1] [1] → [√ OK] (1. CMS Test)
[Fx] [8] → [Code XXXX] → [1] [2] → [√ OK] (2. CMS Test)
• LCD Keypad;
[Fx] [8] → [Code XXXX] → [1-CMS Test Call]→[√ OK]→[1] (1. CMS Test)
[Fx] [8] → [Code XXXX] → [2-CMS Test Call]→[√ OK]→[1] (2. CMS Test)
To exit test menu press [X] key.
10.2 USER CALL TEST
To test user calls proceed following process.
• LED Keypad;
[Fx] [8] → [Code XXXX] → [2] [1] → [√ OK] (1. User Call Test)
[Fx] [8] → [Code XXXX] → [2] [2] → [√ OK] (2. User Call Test)
• LCD Keypad;
[Fx] [8] → [Code XXXX] → [2- Prvt. Test Call]→[√ OK]→[1] (1. User Call Test)
[Fx] [8] → [Code XXXX] → [2- Prvt. Test Call]→[√ OK]→[2] (2. User Call Test)
To exit test menu press [X] key.
10.3 SİREN TESTİ
To test siren, proceed following process.
• LED Keypad;
[Fx] [8] → [Code XXXX] → [3] [1] → [√ OK] (1. Siren Test)
[Fx] [8] → [Code XXXX] → [3] [2] → [√ OK] (2. Siren Test)
• LCD Keypad;
[Fx] [8] → [Code XXXX] → [3- Siren Test]→[√ OK]→[1] (1. Siren Test)
[Fx] [8] → [Code XXXX] → [3- Siren Test]→[√ OK]→[2] (2. Siren Test)
To exit test menu press [X] key.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
64 / 81
10.4 PGM TEST
To test PGM, proceed following process.
• LED Keypad;
[Fx] [8] → [Code XXXX] → [4] [1] → [√ OK] (PGM Test)
• LCD Keypad;
[Fx] [8] → [Code XXXX] → [4- PGM Test]→[√ OK]→[1] (PGM Test)
To exit test menu press [X] key.
10.5 PGM CONTROL
For PGM Control proceed following precess.
• LED Keypad;
[Fx] [8] → [Code XXXX] → [5] [1] → [√ OK] (PGM Control)
• LCD Keypad;
[Fx] [8] → [Code XXXX] → [5- PGM Control]→[√ OK]→[1] (PGM Control)
To exit test menu press [X] key.
11. APPLICATION
Basic information about operating the system according to various scenarios and applications and
how to program them according to these scenarios will be explained under this title.
11.1 FIRE DETECTOR CONNECTION WITH PGM OUTPUT
It is possible to take precautions against fire risks by connecting smoke detector to alarm panel. Fire
detectors trigger the alarm system when they detect smoke or heat in the environment and turn on
the red LED warning lights to give a visual warning on the detector.
When the detector detects it needs to be reset and returned to normal. This is achieved by cut the
power of the detector and received back. To prevent this from being physically accessed and
removed from the base, the detector supply can be supplied via the PGM output. In this way, when a
fire alarm occurs in the system and user code is entered to cancel alarm, the detector's supply can
be interrupted for a certain time and the detector can be reset. For this type of operation, both the
connection method and programming should be done as follows:
When the + 12V input of the smoke detector is connected to the
AUX output, the -12V input must be connected to the PGM
output. When the PGM output is programmed as “Fire
Detector”, the PGM output gives -12V. The time of the PGM
output will interrupt the feed is set in the PGM Parameter
section.
Figure 22: PGM Connection for Smoke Detector
Smoke Detector
Detector Base
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
65 / 81
To set PGM Type as Fire Detector;
• LED Keypad;
[13] [01] → [5] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[PGM Settings √ OK]→[Use PGM as “Fire Sensor”]→[√ OK]
PGM Reset Time;
• LED Keypad;
[13] [02] → [X second] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[PGM Settings √ OK]→[PGM Setting X Second]→[√ OK]
11.2 FIRE SIREN CONNECTION WITH PGM OUTPUT
The alarm system is programmed to notify any alarm conditions with an external siren. If a fire
alarm occurs in the system, a different type of siren can be used to isolate the fire alarm from the
burglar alarm and this siren can only sound in case of a fire alarm.
The fire siren is connected to the PGM output as shown and
“Fire Siren” option is selected as PGM type from the program.
If the PGM type is set to “Fire Siren”, a parameter setting is not
required. This output is active as long as the system gives a
fire alarm.
To set PGM Type as Fire Siren;
• LED Keypad;
[13] [01] → [4] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[PGM Settings √ OK]→[ Use PGM as “Fire Siren”]→[√ OK]→[√ Tamam]
11.3 PARTITION
Pars series alarm panels can be used by creating a total of four (4) different partitions. Zones for
each partition can be specified and alarm notifications from each partition can be forwarded to the
related persons. In addition, four different keypads can be selected for four different partition and
users can be restricted in the corresponding partition.
In this way, for example; in a company with office, production, warehouse and finance departments,
the user can use the system according to which department has the authority arm and disarm. In
addition, different keypads can be installed in these partitions to arm and disarm in independent
time periods and alarm notifications from the related partitions can be directed to authorized
persons in those partitions.
Figure 23: PGM Connection for Fire Siren
Fire Siren
Sounder Base
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
66 / 81
First of all, it is necessary to assign the zones to the relevant partitions in order to define the
partition. If no zone is assigned, all zones are defined in partition A and the system is used with a
single partition.
To assigned the zones to a related partition see the section 7.5 Zone Settings - 7.5.2 Partition
Separate Entry-Exit time can be defined in each Partitions. In this way, different partitions can be
arm-disarm at different times.
To set different Entry-Exit times for partitions see the section 7.3 Basic Settings 7.3.2 Exit
Delays and 7.3.3 Exit Delays.
If more than one Keypad is to be used, settings should be made on which Keypad is authorized for
which partition. In this way, any partition with an unauthorized keypad can be prevented from
performing arming and disarming.
PS: A Keypad can be authorized for a single partition or can be authorized for multiple partitions.
To assigned Keypads to Partitions see the section 7.6 Keypad Settings 7.6.2 Keypad
Partitions.
By specifying which users are authorized in which partitions, specific users can be arm and disarm
the partitions their assigned only. This will prevent the unauthorized user from arm and disarm the
relevant partition.
To assigned users to partitions see the section 7.7 User Settings - 7.7.4 User Partitions.
For each partitions, AHM reports, user phone calls and SMS notifications can be forwarded to
different user numbers. In this way, users can receive alarm notifications only from the
departments they are authorized.
To set notifications according to partitions see the section 7.8 Communicator Settings - 7.8.1
General Settings.
11.4 HAREKETSİZLİKTE OTOMATİK ALARM KURMA
Sistemin kurulu olduğu mahalde, belirli bir süre boyunca herhangi bir hareket algılanmaz ise
sistemin otomatik olarak kurulması sağlanabilir. Bu sayede yüksek güvenlik gerektiren yerler için
alarm sisteminin kurulmasının unutulmuş olması gibi durumlarda sistem belirlenen bir süre içeride
herhangi bir hareket algılamaz ise sistemi otomatik olarak kurar.
Hangi bölümlerin hareketsizlik durumunda otomatik kurulacağı aşağıdaki gibi seçilir.
• LED Keypad;
[12] [07] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[Auto Arm/Disarm √ OK]→[Inactivity Arm A-B-C-D]→[√ OK]
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
67 / 81
How many minutes of inactivity occurs within the section is selected as follows. The value can be
set between 5 - 255 minutes.
• LED Keypad;
[12] [08] → [1-2-3-4] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK]→[Auto Arm/Disarm √ OK]→[Inact. Arm Delay MM]→ [√ OK]
11.5 ARM / DISARM WITH CALENDER
The system can be programmed to automatically arm and disarm on specified days and times..
You can set auto arm and disarm times for each partitions separately. To do this see the section; 7.4
Panel Settings 7.4.3 Auto Arm/Disarm.
11.6 HOME – AWAY ARMING
The alarm system can arm in two different modes. One of them is “Home Arming” and the other is
“Away Arming”.
When the system armed with Home Arming, the detectors which set as “Include Home Arming” will
be disabled automatically. For example, if you want to arm the system in the house at night, the
motion sensors in the space must be switched off in order to move freely inside. To do this, “Include
Home Arming” feature must be defined to these zones.
This zones will not trigger any alarm when the system is armed as Home Arming. For this reason, it
is important to have window and door magnetic contacts in the systems where this feature will be
used.
To assigned to a zone “Include Home Arming” feature;
• LED Keypad;
Zone 1 - [23] [01] → [6] → [√ OK]
• LCD Keypad;
[Zone Settings √ OK]→[Extra Settings √ OK]→[1- Zone Settings “Enable 6”]→[√ OK]
Include Home Arming feature can be defined for each zone as shown above.
PS: For Home Arming, use the shortcut key on the keypad. The disarming
process for Home Arming is the same as the standard disarming process.
Away Arming basically has the same function as the whole system arming.
You can use the shortcut key to arm whole system (Away Arming) as well.
Home
Away
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
68 / 81
12. REPORTS
Information about the current status of the alarm system can be found in this section. Trouble can
also be displayed in this menu. Following reports can be seen in this menu;
Armed Zones: Information about which zones are currently armed in the system.
• LED Keypad;
[Fx] [6] → [Master Code] → [Press 1]
Indicates the armed zones on the Keypad.
• LCD Keypad;
[Fx] [6] → [Master Code] → [1-Armed Zones]→ [√ OK]
Indicates the armed zones on the Keypad.
Last Alarm Zone: Information about the last zone which triggered alarm in the system.
• LED Keypad;
[Fx] [6] → [Master Code] → [Press 2]
Indicates the last alarmed zones on the Keypad.
• LCD Keypad;
[Fx] [6] → [Master Code] → [2-Last Alarm]→ [√ OK]
Indicates the last alarmed zones on the Keypad.
PGM Status: Information about which PGM is active currently.
• LED Keypad;
[Fx] [6] → [Master Code] → [Press 3]
Indicates the PGM Status on the Keypad.
• LCD Keypad;
[Fx] [6] → [Master Code] → [3-PGM Status]→ [√ OK]
Indicates the PGM Status on the Keypad.
Keypad Address: Information about the related Keypad Address.
• LED Keypad;
[Fx] [6] → [Master Code] → [Press 4]
Indicates the Keypad Address on the Keypad.
• LCD Keypad;
[Fx] [6] → [Master Code] → [4-Keypad Address]→ [√ OK]
Indicates the Keypad Address on the Keypad.
Bypassed Zones: Information about the zones which bypassed.
• LED Keypad;
[Fx] [6] → [Master Code] → [Press 5]
Indicates the bypassed zone(s) on the Keypad.
• LCD Keypad;
[Fx] [6] → [Master Code] → [5-Bypassed Zones]→ [√ OK]
Indicates the bypassed zone(s) on the Keypad.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
69 / 81
Troubles: Information about the current Troubles in the system.
• LED Keypad;
[Fx] [6] → [Master Code] → [Press 6]
Indicates the Troubles on the Keypad one by one. You can find the Trouble codes below.
• LCD Keypad;
[Fx] [6] → [Master Code] → [6-Troubles]→ [√ OK]
Indicates the Troubles on the Keypad one by one.
LED Trouble codes and related LED information are indicated on the keypad as follows;
0-1
Power Failure
1-0
Keypad Connection Fault
0-2
Low Battery
1-1
GSM/GPRS Module Fault
0-3
Wrong Time and Date
1-2
PSTN Module Fault
0-4
No PSTN Line
1-3
Ethernet Modul Fault
0-5
Zone Fault
1-4
SIM Card Fault
0-6
Battery Fault
1-5
GSM Communication Fault
0-7
Tamper
1-6
GPRS Communication Fault
PS 1: LED Keypad displays fault messages by illuminating zone numbers in sequence. For example, if
the PSTN Module Error occurred in the system, when entering the Reports - Troubles section, the
LED Keypad will display as follows;
[1] [2] will light up and then all LEDs will light up.
PS 2: If more than one fault is present, the LED Keypad displays all faults in sequence. All LEDs flash
simultaneously between each fault indication. For example, if both PSTN Module Error and SIM Card
Error are present in the system, when you enter the Reports - Troubles section, the LED Keypad will
display as follows;
[1] [2] will light up and then all LEDs will light up. Then [1] [4] will light up and then all LEDs
will light up.
GSM Signal: GSM signal level can be displayed on panels with GSM sim card. GSM signal shown as
percent “%” . Access to GSM signal level information is as follows and the value shown here can be
interpreted according to the following information.
• LED Keypad;
[Fx] [6] → [Master Code] → [Press 7]
Signal Level according to LED indicates;
1: Signal Level Between %1 - %12,5
1-2: Signal Level Between %12,5- %25
1-2-3: Signal Level Between %25 - %37,5
1-2-3-4: Signal Level Between %37,5 - %50
1-2-3-4-5: Signal Level Between %50 - %62,5
1-2-3-4-5-6: Signal Level Between %62,5 - %75
1-2-3-4-5-6-7: Signal Level Between %75 - %87,5
1-2-3-4-5-6-7-8: Signal Level Between %87,5 - %100
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
70 / 81
• LCD Keypad;
[Fx] [6] → [Master Code] → [7-GSM Signal Level]→ [√ OK]
GSM Signal Level indicates as Percent.
GSM signal level percentages can be interpreted according to the following table.
GSM Signal Level
Status
%0
No GSM Signal
%1-%20
GSM Signal is Weak
%20 - %70
GSM Signal is OK
%70 - %100
GSM Signal is Very Good
!!! Important !!!
If the GSM Signal is below 20%, the system's call, SMS sending, and GPRS connections may be
unstable. In this case, a longer antenna may be need to installed in the GSM module or the alarm
panel may need to be installed in a more suitable location.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
71 / 81
13. KEYPAD USAGE
This section describes the Keypad used for all functions of the alarm system and for panel
programming.
Teknim Pars serisies alarm systems supports totally 4 keypad connection. Information on how to
make the keypad connections can be found in section 6.5 Keypad Connection.
TSK-5718 LED KEYPAD
TSK-5710 LCD KEYPAD
Figure 24: TSK-5718 LED Keypad
Figure 25: TSK-5710 LCD Keypad
Status
Notification LED
Indicators
Status
Notification LED
Indicators
Partition and
Arrow Keys
Shortcut
Function Keys
Numeric Keys
and Ok-Cancel
Keys
2x16 LCD Screen
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
72 / 81
13.1 STATUS LED INDICATORS
Status LEDs provide information about the current status of the system. The explanations of the
status LED indicators are as follows;
Power: Indicates whether the Alarm Panel has power. If it is steady, it means there is main power, if
it is not, it means no main power.
Program: Indicator for entering alarm panel programming menu.
Bypass: Indicates that the system has a temporarily canceled zone(s).
Memory: Informs the system that an error or alarm condition has occurred and that the memory
needs to be checked.
Ready: Indicates that all zones are closed and the alarm system is ready to be installed.
Armed: Indicates that the system is armed.
Trouble: Indicates that the system has an error condition. What is the error can be seen in the
corresponding menu.
Fire: Indicates system has fire alarm warning.
13.2 FUNCTION KEYS
Away Arming: This key is used to arm the whole system with a shortcut without
entering a user code. Press and hold this key for 1sec to arm quickly.
Home Arming: This key is used to arm inside in the house to cancel predefined
detectors. Press and hold this key for 1sec to home arming.
Function: Used to run secondary tasks on numeric keys. For example, to enter the
Installer Program, you must press the number 4 after the FX key.
Bypass: Used to temporarily cancel any zone(s).
13.3 PARTITIONS AND ARROW KEYS
Use as Partition Keys: Alarm system can be divided into 4 different
partitions and each part can be arm and disarm separately. When this
type of partitioning is done, you can arm each partition with “Partition
Shortcut” buttons. You can press and hold the shortcut key of the
partition you want to arm (A, B, C, D) until you hear a beep, or you can
select multiple partition keys and end the process by entering user code
for arming or disarming.
Use as Direction Keys: You can use these keys in the form of directional
keys when the alarm panel is in programming mode or when navigating
through any menu.
Figure 29: Partition and
Arrow Keys
Away
Home
Function
Bypass
Figure 28: Function Keys
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
73 / 81
13.4 KEYPAD
Numeric Keys: Keys used to enter values in all keypad operations. Each
key has a secondary function. Also, when typing zone names on LCD
Keypad, defined letter groups are used on these keys.
Secondary Functions: Press and hold the key until the beep sounds to
operate the secondary functions defined on the keys.
1: Panic Alarm - 2: Fire Alarm - 3: Medical Alarm - 4: Enter Programming
5: Bypass - 6: Report Menu - 7: Chime - 8: Test - 9: Memory - 0: Reset
Confirmation key to confirm an operation for any menu or exit
key to discard and exit an operation.
.
13.5 KEYPAD NOTIFICATIONS
13.5.1 KEYPAD SOUND NOTIFICATIONS
When you enter any value into your system via the keypad, you will hear a beep, which means
confirmation or rejection.
Confirmation Sound: When any information is successfully entered or the system switches to a
new mode, the keypad emits two short "beeps", which means confirmation.
Rejection Sound: The keypad emits a long "beep" meaning rejection when incorrect information
is entered or the system switches to the previous mode.
13.5.2 KEYPAD LED NOTIFICATIONS
LED and LCD keypads have status notification lights to indicate the current status of the system.
What these notification lights mean is explained in section 13.1 Status LED Indicators.
LCD Keypad can also display all information about the system in writing.
Figure 30: Keypad
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
74 / 81
14. FAQs
FAQs
Question
Solution
KEYPAD
On TSK-5718 Keypad, 1-2-3-4-5-6-
7-8 and Trouble lights blink
simultaneously.
Check keypad connection and keypad address. The total
length of the keypad cable should not exceed 100 meters.
If you have connected more than one keypad to the
system, enter the Installer program from the number
Keypad number 1. Check the 2nd, 3rd and 4th keypad
addresses. In program at the 3002, 3003, 3004 address,
option 1 must be active. In this case, 2nd, 3rd and 4th
keypads will work.
I get “Connecting” Fault on
Keypad.
1: Make sure the keypad is properly connected.
2: Make sure that the keypad address is given and that
there are no other keypads on the same line with same
address.
3: Make sure the USB cable is not connected to the panel.
4: Make sure that the USB-PC connector is not connected.
How many keypad zones can I use
on the alarm panel?
There is 1 zone for each keypad. Keypad zones can be
used up to the number of keypads connected to the
system. Max. 4 keypad zones can be used. In order to
activate the keypad zone, the alarm terminals of the
detector must be connected to the mag and gnd terminals
on the keypad and the power must be supplied from Aux.
Zone names do not appear on
other keypads.
Zone information is stored on the keypad and must be set
for each keypad. You cannot view from other keypads or
PC.
Why the keypad zone does not
work.
Keypad zones are closed as a factory default. You must
activate them first.
How many keypads can I use in an
alarm panel?
You can use 4 keypads. LCD or LED keypad does not
matter, the last keypade termination jumper must be
installed and the cable length of keypads should not
exceed 100 mt.
COMMUNICATOR
User Calls and SMS does not work
when I change the Sim card on the
GSM-GPRS module.
When you replace the sim card, press and hold the button
on the module for 3s.
I bought the TSP-5208P alarm
panel but I want to switch to GSM
module what should I do?
You can use TXM-5272 to use GSM line in the system.
Although there is no SIM card in
the GSM-GPRS module, the signal
strength is visible.
If the GSM module does not have a simcard, it switches to
emergency mode, connects to the nearest base station
and accesses the signal level.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
75 / 81
COMMUNICATOR
User calls doesn not work.
After entering the Installation Program, enter the phone
numbers at 06 01 ~ 06.
Make sure option 2 is selected at address 50 01. When you
set 3 at address 50 02, the number of attempts will be set
to 3.
Reports cannot send Central
Monitoring Station.
After entering the Installation Program, enter the account
number at 04 01 for first CMS
Set CMS numbers at 05 01 and 05 03 for CMS 2
Make sure option 1 is selected at address 50 01.
I can’t remotely arm the control
panel by phone.
After entering the Installation Program, enable option 1 at
15 01. Set the ring count at 15 02.
When you call the control panel by phone after
confirmation sound dial *code# and after confirmation
dial *1# to arm system.
Control Panel does not send SMS
Make sure option 3 is turned on at address 50 01.
In case of alarm all registered
phones are dialed or the panel
calls the same number more than
once.
Edit the options “End Calls on Firs Confirmation” and “End
Calls By Pressing any Key” under the Communicator Menu
as your needs.
Alarm panel continuously calls by
phone.
Control panel calls the users as many time as you set
after alarm condition. After you answer your phone, press
* to stop calls. Alarmı çözmek ve sireni susturmak için ise
ek olarak *şifre# onay sesinden sonra *0# yapınız.
Can I turn off all SMS?
Yes, Communicator - General Settings – Turn off 3, you
will close all SMS.
Can I use a mobile application
when there is no internet package
on my SIM card?
If your SIM card does not have internet access, you cannot
use the mobile application. GSM; Allows calls and SMS
sending. GPRS; Provides an Internet (data) connection.
Sim card is connected but control
panel can’t make calls or send
messages to CMS.
Probably the SIM card pin code is not turned off. You
cannot operate until the pin code is removed.
Phone Calls and SMS are working
but I have a problem with Mobile
application not stable.
Check the GSM / GPRS signal level. This problem may
occur when the signal level is low. A better quality signal
is required for the GPRS connection
I cannot make CMS
communication with the
GSM/GPRS module.
i. The SIM card used may not have internet on by the
network service provider.
ii. GPRS communication may be turned off in the module
settings section (factory setting is on).
iii. Your CMS account number, port number, or IP address
may be incorrect.
iv. There may not be Teknim Receiver software in CMS
attempting to establish a connection.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
76 / 81
COMMUNICATOR
I cannot send SMS.
i. The SMS sending setting may be off. In the factory
settings, SMS sending is off and needs to be turned on
after entering the phone number.
ii. At the beginning of the number you want to send an
SMS "COUNTRY CODE 00" (for example, Turkey 0090)
must be entered. Some mobile operators cannot send
SMS without country code at the beginning.
Some events do not send SMS, do
not send message to CMS or make
calls.
Under the report masks menu, settings such as call, sms
or CMS notification can be selected and customized. Some
options are closes as a factory default.
When I call the panel by phone,
the panel does not respond.
At the ”Remote Access Settings” make sure option 1 is
turned on.
BATTERY
Control Panel does not operate
from battery only.
If the control panel will be operated only by battery
without mains connection, after the battery connection is
made, press and hold the Start button on the panel board
for 3 seconds. Otherwise, the battery will not turn on until
power is applied.
Battery charge light does not turn
off when power is göne.
The battery charge light will go out in 1 minute, if the
power goes out during the charging phase, it can detect in
1 minute.
How do we know that the panel
works?
If the status led on the panel flashes every 3 seconds, the
panel is running. Flashes at different times during arming
and disarming.
The charging light is on
continuously.
To maximize the life of your battery, a charged battery
operates in 56sec charge, 4sec discharge mode.
SOFTWARE
Which Code should I use to login
from PC Configuration Software?
If you are going to program Pars alarm systems via a PC,
you should get the PC configuration program first. When
connecting to the control panel with this software, you
can log in using the Installation Code of the panel. Factory
Default: 9999
When making a PC connection, I
get a disconnected error.
When connecting the PC to the panel, make sure that the
alarm is not armed.
How to change user codes with
configuration software?
For security reasons, the codes cannot be changed from
the configuration software.
CODES
While everything appears normal
on the panel, I get "Access Denied"
error when try to login to Installer
Program.
Make sure your code is correct. If your code is correct, you
may not be able to log in due to a previously occurring
alarm condition (Panic Alarm, Medical Alarm etc.). You
cannot log in unless the alarm restores.
I receive an “ERROR: WRONG
PASSWORD” warning when I try to
arm the system.
1: Make sure your code is entered correctly.
2: Make sure that the Fx key is not active, if the Fx key is
active, the ready light flashes.
How to delete user Codes?
User codes can be deleted by entering 0000 in the section
of user codes.
When the user code is deleted,
will the remote keyfob which
connected to the user code work?
When the user code is deleted, the remote control keyfob
is also automatically deleted.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
77 / 81
CODES
I forgot my master code, what
should I do??
Contact technical service.
Smoke detector is not reset by
user code after gives alarm,
although it is supplied from the
PGM output. Red light stays on, it
resets when I unplugged the
detector from base.
Make sure the smoke detector is connected correctly and
make sure that its parameters are correctly entered.
How many external sirens can be
connected to the alarm panel?
When using Teknim brand external siren, 2 sirens can be
connected. The second siren must have the internal siren
jumper connected.
Can I connect two different unit to
the same PGM?
No, there may not be a correct connection because the
parameters are different.
How many units can I connect to
the same PGM in one type?
For max limit, connection must be made by calculating the
max current to be drawn by the devices. For example, the
TSD-5135 smoke detector consumes 10 mA, therefore
Max. 10 pcs smoke detector can be connected.
How many detector can I connect
to control panel?
There is no max limit, the total current of the panel must
be calculated and the connection must be made
accordingly.
Can I define a remote keyfob
controller to two different
users??
No, you can’t define same keyfob to another user it gives
“!! Available” Warning.
DİĞER
How many remote keyfob can I
use in the system?
Maximum 11 keyfob can be used with user codes.
Fire detector is constantly gives
Alarm.
1: Be sure to make the appropriate connection by referring
to the user manual.
2: Make sure that the type of zone connected to the fire
detector is selected as “Fire”.
3: Make sure PGM usage type is selected as “Fire
detector“.
4: Make sure that the PGM parameter is entered for the
minimum reset time in seconds of the connected detector.
The system gives alarm when I
walk around in the house even
though I'm arming the system as
Stay Mode.
You have to define “Include Home Arming” to related zone.
Panel functions do not work
properly after firmware upgrade.
After firmware upgrade, the control panel settings return
to the factory defaults.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
78 / 81
MOBILE APPLICATION
I have installed Teknim Mobile
application, but the operation
fails or user not found error
appears in the barcode reading
section.
Another user may have registered this panel under their
account.
I can't Arm/Disarm via mobile
app.
i. The SIM card may not have internet on by the network
service provider.
ii. GPRS communication may be turned off in the module
settings section (factory setting is on!).
iii. Cloud communication may be turned off in the cloud
settings section (factory settings are off!).
iv. If any alarm condition exists, the GSM / GPRS module
may be making a call or sending an SMS. A 2G connection
is lost during a call or SMS sending. Try again when all
calls and SMS are finished.
v. There may be a open or improperly connected zone
while you try arming.
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
80 / 81