Slinex Tabo Operation & User’s Manual

Text of the manual

{ Design. Uniqueness. Innovations }

{ Design. Uniqueness. Innovations } User manual Technical support Thank you for choosing our equipment IP video outdoor station PoE function 720P (1 Mp)

Table of contents

1. Package...................................................................................................................................................................................... 3 2. Specifcation............................................................................................................................................................................. 3 3. Description................................................................................................................................................................................ 4 4. Installation................................................................................................................................................................................. 5 4.1 Schematic diagrams................................................................................................................................................ 5 4.2 Unit mount ................................................................................................................................................................. 7 5. Software setup......................................................................................................................................................................... 8 5.1. «Network» settings................................................................................................................................................. 9 5.2. «Panel» settings ....................................................................................................................................................... 9 5.3. «Access management» settings......................................................................................................................... 11 5.4. «Forward» settings.................................................................................................................................................. 13 5.5. «Advanced» settings.............................................................................................................................................. 13 5.6. «Security» settings.................................................................................................................................................. 14 5.7. «System» settings.................................................................................................................................................... 15 6. Limited warranty..................................................................................................................................................................... 16 Attention! As a result of continuous upgrades and functionality improvements, technical characteristics of the device can be changed without any preliminary declaration. This manual can contain some inaccuracy or misprint. The owner reserves the right to make corrections to the information described in the user manual and device package. The last revision of this manual is available on www.slinex.com Safety instructions Please read and keep that manual. The device installation process should be carried out by the qualifed specialists. Use the device from the –40 ˚C to +50 ˚C (–40 ˚F to 122 ˚F), always keep it within that temperature range. Installation surface should be free from vibration and impact infuence. Keep this device far from open sources of heat, such as radiators, heaters, and ovens. The device can be installed near other electronic equipment in case if the temperature of the environment does not exceed previously mentioned range. The device should be protected from the direct infuence of the natural phenomena, such as direct sunlight, rain or snow. Don’t use aggressive or abradant detergent for the device surface cleaning. Use soft wet cloth or tissues to remove strong dirt. Nature protection Don’t throw away the device with other industrial or nutritive trash if you see that symbol. Some regions have separation and recycling systems for the electronic equipment. Connect with local authorities to receive information about recycling of electronic equipment for your region. Rights and limitation of liability All rights reserved. Any part of that document can not be published in any form, translated into other languages or reproduced in any way including electronic or mechanical. Document recording and copying are strictly forbidden without owner permission. ! Tabo 1 REV. 1.0 2

Tabo video outdoor station – 1 pc.

Surface mount bracket – 1pc. Surface mount bracket with rain shield – 1 pc. Connection wires kit – 1 pkg. Wires cap – 1 pkg. Mounting screws – 1 pkg. User manual – 1 pc. 2. Specifcation 5 1 2 3 4 6 3. Description Wire connectors pinout 160 mm (6.30") 102 mm (4.01") 29 mm (1.14") Tabo 3 4 SENSOR 1/4” CMOS RESOLUTION 720p (1280x720), H.264 Main Profle HORIZONTAL VIEW ANGLE 100˚ LOCK RELAY CONTINUOUS CURRENT 10 A BACKLIGHT TYPE White LED’s - 6pcs. POWER DC 12 V or PoE (802.3af standard) WORKING MODE POWER CONSUMPTION 6.5 W MOUNTING TYPE Surface mount with fush area (25×60×40 mm) DIMENSIONS 102×160×46 mm (4.01×6.30×1.81") WORKING TEMPERATURE –40 ... +50 ˚C (–40... +122 ˚F) 7 NO COM NC +12V GND 485+ 485- DIN DS GND EXIT Lock relay output RS 485 interface Exit / Door sensor Power supply Wiegand 26 interface LAN connector PoE (802.3af) +12V GND D1 GND D0 39 mm (1.54")

Tabo outdoor station can be powered by12V power supply or by PoE (802.3af) through LAN connector.

Note: Total network cable length between devices must not exceed 80 meters for PoE connection (red) and 100 meters for ordinary connection ()without PoE. Diagram 2. Basic network connection 4. Installation 4.1 Schematic diagrams Diagram 1. Tabo mechanical lock connection Internet connection Tabo 5 6 Mechanical lock Lock power supply COM NO Magnetic lock Lock power supply NC COM Exit GND Open lock button Diagram 2. Tabo electromagnetic lock connection Power supply 12V, 2A +12V GND +12V GND Imani indoor monitor Tabo outdoor station Router with PoE WAN 1 2 3 4 CAT5 twisted pair cable CAT5 twisted pair cable with PoE

4.2 Unit mount

1) Take an appropriate bracket from the kit and place it 150-160 cm (4.9-5.2 ft.) from the foor line. 2) Mark and drill two halls and prepare space in the wall that should be used for wires setup. 3) Take two wall anchors from the kit and hammer them into the drilled halls. 4) Fix the bracket on the wall by the screws from the kit. 6) Connect all communication wires and fx the outdoor station on the mounting bracket by one screw from the bottom side. Tabo 7 8 Surface mount Rainshield mount 5. Software setup Door station default IP address is 192.168.1.90 or 192.168.1.91 Enter this IP adress into PC’s browser address line to enter web interface. Note that your PC must be in the same segment of local network (i.e. it has IP adress like 192.168.1.XXX where XXX is any number between 2 and 254, excluding 90). Enter to the web interface using next parameters (by default): Login: admin Password: 123456 Then press “SIGN IN” button: Below you can see web interface main screen: Here you can find current door station firmware version and network parameters, such as DHCP status, Gateway IP address, Door station IP address, DNS server, Subnet mask and MAC address.

5.1. «Network» settings

Press «Network» bookmark on the left side of the screen to enter network settings: DHCP – disable to enter IP address manually or enable to receive IP address automatically from network device (like router); IP – device IP address; Mask – device subnet mask; Gateway – network gateway; DNS – DNS serever IP address; NTP – enable or disable automatic date and time synchronization with NTP server; URL – NTP server address. 5.2. «Panel» settings Room settings Press «Panel» bookmark on the left side of the screen to enter panel settings: Mode– device mode can be only «Personal» for this outdoor station; Building – building number; Unit – unit number; Floor – floor number; Apartment – apartment number; Device number – if there are several outdoor panels then use different device number for each device (1-9). Full logical address of the outdoor station consists of 11 figures, for example: 10001020304 (100 - 1st device number, 01-building, 02-unit, 03-floor and 04-apartment number). SIP settings Enable/Disable – enable/disable SIP function; Proxy – proxy server name (default value – sip:pbx.slinex.com ); Realm – authentication host (default value – pbx.slinex.com); STUN IP – STUN server name (default value – stun.I.google.com); STUN port – STUN port number (default value – 19302); User – SIP account user name; Password – SIP account password;

Call and Device settings

Enabled – enable/disable consierge function; Number – consierge SIP number ; Call max time – calling time in seconds; Talk max time – talking time in seconds; Video quality – video resolution 320x240, 640x480 or 1280x720; RTP data profile – rtp stream data profile (default value – 102); Volume level – outdoor station volume from 1 to 6. 5.3. «Access management» settings Press «Access management» bookmark on the left side of the screen to enter access management settings. Access management Master card – master card number (if panel has wireless ID reader); Use master code – enable/disable master code; Master code – master code value. Locks management Lock open time – lock opening time in seconds; Lock open delay – delay before lock opening in seconds. Open lock Lock #1 OPEN LOCK – initiate lock #1 opening; Lock #1 OPEN LOCK – initiate lock #2 opening (if 2-lock extension unit is installed). Additional settings Floor number (elevator control) – specify floor number for elevator control; Monitor secure mode – enable/disable monitor secure mode.

5.4. «Forward» settings

Press «Forward» bookmark on the left side of the screen to enter forward settings. This bookmark contains call forward settings. Click «New forward» button to add forwarding rule. Apartment number – specify your door station number (consists of four figures, two figures floor and two figures number of apartment, for example 0301) from which forwarding will be applied. Forward number – specify monitor number to forward to. Here you have to enter “sip:[email protected]” where 01 is the floor 13 is apartment number and 192.168.15.100 is monitor IP adress. You can also add several numbers for call forwarding by pressing «Add» button. If the first number doesn’t answers during 20 seconds then the call forwards to the second one and so on. 5.5. «Advanced» settings Press «Advanced» bookmark on the left side of the screen to enter advanced settings. In this bookmark you can add up to 4 RTSP streams from IP cameras to view while calling. Switching between streams performed by pressing “1-5” button, where “1” is the door station camera stream and “2-5” are IP cameras streams. Click «ADD» button to add IP camera RTSP address. URL – IP camera RTSP stream address. For example: rtsp://admin:[email protected]:8554/ch01 5.6. «Security» settings Press «Security» bookmark on the left side of the screen to enter Security settings. Here you can change administrator or manager password. User name – select user name; Old – enter old password; New – enter new password; Confirm – confirm new password.

6. Limited warranty

Manufacturer guarantees product normal functioning during the warranty period if the user keeps all safety instructions described in that manual. Warranty period is 12 months from the moment of the product purchasing (warranty period could be extended up to 24 months or more, depending on the local regulations). Warranty period allows user to make guarantee repair in cases when normal functioning of the product was violated by the fault of manufacturer and the user haven’t ofend transporting, installation and working conditions. This limited warranty does not cover any damage to the product that results from improper installation, accident, abuse, misuse, natural disaster, insufcient or excessive electrical supply, abnormal mechanical or environmental conditions, or any unauthorized disassembly, repair or modifcation. Warranty void in such cases: • the product was damaged by the fault of the customer; • the product wasn’t properly installed according reccomendations from the manual; • the sticker on the backside of the product was broken; • the product was not used for its intended function. This limited warranty covers only repair, replacement, refund or credit for defective products, as provided above. Manufacturer is not liable for, and does not cover under warranty, any damages or losses of any kind whatsoever resulting from loss of, damage to, or corruption of, content or data or any costs associated with determining the source of system problems or removing, servicing or installing products. This warranty excludes third party software, connected equipment or stored data. Manufacturer is therefore not liable for any losses or damage attributable to third party software, connected equipment or stored data. In the event a product has been discontinued, manufacturer shall either repair the product, ofer to replace it with a comparable product or provide a refund at the lesser of the purchase price or the product’s current value. Repaired or replacement products will continue to be covered by this limited warranty for the remainder of the original warranty term. 5.7. «System» settings Press «System» bookmark on the left side of the screen to enter system settings. Restore settings – reset all door station settings to default values; Language – change door station language; Reboot – restart door station.

Other Intercom System Manuals