Siemens Building Technologie

74 319 0612 0 c M1329 2019-03-05 1/2 74 319 0612 0 C M1329 TRG2 TRG22 TRG2 AC 250 V / 10(2) A 2 1 4 2 1 4 y XK Dt [xD ] t[°C] 9I804 Sollwert Der Sollwert wird mittels der Skala von -5°C…50°C eingestellt. Setpoint The setpoint is adjusted with the operating scale between - 5°C…50°C. Consigne La consigne est définie avec la règle dans une plage -5°C…50°C. Setpoint Il setpoint può essere regolato con la scala di funzionamento da - 5°C…50°C. . Consigna La consigna puede ajustarse mediante la escala de -5C…50°C. Gewenste waarde De gewenste waarde kan worden ingesteld tussen -5°C…50°C. TRG22 AC 250 V / 10(2) A Sollwert / Schaltdifferenz / Schaltabstand Sollwert xK einstellbar mit Schraubenzieher von -5…50°C / Schaltdifferenz x0 fix auf 2K / Schaltabstand Δx einstellbar von 1…12K (Werkeinstellung: 1K). Setpoint / Switching differential / Switching distance Setpoint xK adjustable with screwdriver between -5…50°C / Switching differential x0 fixed at 2K / Switching distance Δx adjustable between 1…12K (factory setting: 1K). Consigne / différentiel / intervalle de commutation Consigne xK réglable par tournevis dans une plage -5…50°C / différentiel x0 fixe à 2K / intervalle de commutation Δx ré- glable de 1 à 12K (par défaut: 1K) Setpoint / Differenziale contatto / Distanza contatti Setpoint xK regolabile con un cacciavite da -5…50°C / Differenziale x0 contatto fisso a 2K / Distanza tra i contatti Δx regolabile da 1…12K (impostazione iniziale: 1K) Consigna / Diferencial de conmutación /Rango de conmutación La consigna xK es ajustable mediante un destornillador desde -5…50°C / el diferencial x0 de conmutación está fijo en 2K / el rango de conmutación Δx es ajustable desde 1…12K (consigna inicial: 1K) Gewenste waarde / schakeldifferentie / schakel-afstand Gewenste waarde xK instelbaar d.m.v. schroevendraaier van - 5…50°C / Schakeldifferentie x0 vast 2K / Schakel-afstand Δx instel- baar van 1…12K (fabrieksinstelling: 1K) Montageanleitung Raumthermostat TRG2 TRG22 Mounting instructions Room thermostat Instructions de montage Thermostat d’ambiance Istruzioni di montaggio Termostato ambiente Instrucciones de montaje Termostato de ambiente Montage-aanwijzing Ruimtethermostaat Δx

74 319 0612 0 c

Siemens Building Technologies TRG2 TRG22 Disposal Return decommissioned or defective thermostats to the manufacturer for disposal in a safe and environmentally appropriate manner. The capillary tube in these devices contains a small quantity of expansion fluid which should not be set free. Do not dismantle or otherwise damage thermostats and treat them as hazardous waste. The expansion fluid is labeled on the thermostat. Comply with all relevant national regulations governing the disposal of hazardous waste. Toluene H225: Highly flammable liquid and vapour H304: May be fatal if swallowed and enters airways H315: Causes skin irritations H336: May cause drowsiness or dizziness H361d: Suspected of damaging the unborn child H373: May cause damage to organs through prolonged or repeated exposure P301 + P330 + P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting P302 + P352: IF ON SKIN: Wash with plenty of soap and water P314: Get medical advice / attention if you feel unwell Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 – 724 24 24 www.siemens.com/buildingtechnologie © Siemens Switzerland Ltd, 1999 Technical specifications and availability subject to change without notice. TRG2 Schaltdifferenz Schaltdifferenz Δt einstellbar von 0.7…6K. Die Werkeinstellung beträgt 0.7K . Überprüfung der absoluten Schaltdifferenz über Sollwert-Skala. Durch drehen der Skala auf Umgebungstemperatur-Niveau können 2 Schaltpunkte ausgemacht werden, welche durch „Clicks“ gehört werden können. Die Differenz dieser zwei Punkte entspricht der Schaltdiffer- enz. Switching differential The switching differential Δt can be adjusted between 0.7…6K. The factory setting is 0.7K. The absolute switching differential can be verified via the setpoint scale. Rotating the scale at ambient environment temperature level allows for detecting 2 switching points by two audible “clicks”. The differential between these two points corresponds to the switch- ing differential. Diferencial de conmutación El diferencial de conmutación Δt se puede ajustar desde 0.7…6K. La consigna inicial es 0.7K. El diferencial de conmutación absoluto puede verificarse a través de la escala. Al girar la escala se detectan 2 puntos de consigna en torno al nivel de la temperatura real del entorno, que pueden oírse mediante dos ‘clicks’. El diferencial entre los dos puntos es equiva- lente al diferencial de conmutación. Differenziale contatto Il differenziale contatto Δt può essere regolato da 0.7…6K. L’impostazione iniziale è 0.7K . Il valore del differenziale può essere verificato attraverso la scala. Ruotando la scala attorno al livello di temperatura ambiente si rilevano i 2 punti d’inserzione che possono essere sentiti con due “click”. La differenza tra i due punti è l’equivalente con il differenziale contatto. Différentiel de commutation Différentiel Δt réglable de 0.7 à 6K. Réglage usine : 0.7K. Vérification du différentiel absolu avec la règle. En tournant la règle jusqu’au niveau de température ambiante, on fixe 2 points de commutation reconnaissables par un „clic“. La différence entre ces deux points constitue le différentiel de commutation. Schakeldifferentie Schakeldifferentie Δt instelbaar van 0.7…6K.De fabrieksinstelling is 0.7K. De absolu- te schakeldifferentie kan worden getest via de instelknop. Door het draaien van de instelknop rond de actuele ruimtetemperatuur kan men 2 schakelpunten detecteren, die door een „klik“ hoorbaar zijn. Het verschil tussen deze twee punten is de schakeldifferentie.

Other Thermostat Manuals