Document No. 129-604

July 13, 2010 QFA1000, QFA1001 Room Hygrostats Item Number 129-604, Rev. AA Page x of x Product Description These instructions explain how to install a QFA1000 or QFA1001 Room Hygrostat. Product Numbers QFA1000 Internal Setpoint QFA1001 External Setpoint Required Tools • 7 mm flat-blade screwdriver • Phillips head screwdriver • Two 6 × 32 screws • Electric drill Expected Installation Time 10 minutes Prerequisites The base has cable entries at the rear for mounting the room hygrostat on recessed conduit boxes. For wall mounting, appropriate holes at the top or bottom can be knocked out. Mounting Location The hygrostat should be mounted: • on an inner wall approximately 4.9 feet (1.5 m) above the floor, and at least 1.6 feet (0.5 m) from the closest adjoining wall. • where there is a natural circulation of room air (do not mount near drafts, in corners, behind curtains, too close to doors and windows, or on an outer wall). • away from sources of heat and refrigeration (radiators, computers, televisions, concealed heating pipes, hot or cold water pipes). • where it is not exposed to direct sunlight. SEN0576R1 Figure 1. Recommended Mounting Locations. Installation 1. Using a 7 mm flat-blade screwdriver, insert the blade into one of the slots on the side of the housing base. Pry the base away from the housing cover. 2. Do the same for the second slot, so that the cover loosens from the housing base. 3. Flip open the hygrostat cover. SEN0577R1 1 3 2 (~7 mm) (>5mm) >0.20 0.27 Figure 2. Opening the Unit. 4. Before mounting the hygrostat, run the cable through the back of the housing, and terminate the lead wires appropriately, based on how the unit is intended to operate (either switching on humidification or on de-humidification). See Figures 4 and 5.

Document No. 129-604

Installation Instructions July 13, 2010 5. Attach the base of the hygrostat to the wall using two 6 × 32 screws. (Screws are not provided.) Place the screws opposite each other in the housing, as appropriate, to achieve a solid mounting. (See Figure 3.) SEN0578R1 Figure 4. Humidification. Figure 3. Wiring Diagrams Figure 5. Dehumidification. SEN0579R1 3 2 1 Var. 2 Var. 1 Var. 2 max. Ø 0.39 (max. Ø 10 mm) max. Ø 0.27 (max. Ø 7 mm) Var. 1 Figure 6. QFA1001 Pictured. Page 2 of 3 Siemens Industry, Inc.

Document No. 129-604

Installation Instructions July 13, 2010 Setpoint Setting QFA1000: 1. Set the humidity setpoint to the desired setting. (See Figure 7.) 2. Replace cover. 3. Device will be activated when wiring is terminated to the controller. SEN0580R1 1 3 2 + – = 55 H% 1 2 3 = 80 H% = 90 H% Figure 7. QFA1000 Setpoint Setting. QFA1001: 1. Replace cover, aligning external setpoint knob to internal setpoint. 2. Adjust setpoint. SEN0581R1 Figure 8. QFA1001 Setpoint Setting. The installation is now complete. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. © 2010 Siemens Industry, Inc. Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A. Your feedback is important to us. If you have comments about this document, please send them to [email protected] Document No. 129-604 Printed in the USA Page 3 of 3

Other Thermostat Manuals