Key Pages of Document
Communication System Manual
3WN6 Circuit-Breakers Version 1.0 (05/98) Copyright Siemens AG 1998. All rights reserved. 53 RELEASE N and P H and J/K D and E/F PLC input data from 3WN6 (cyclic) OCTET 9 Ready to close BIT 15 X X X Load shedding BIT 14 X X X Reserved BIT 13 X X X Phase number for main actual value BIT 12 X X X Phase number for main actual value BIT 11 X X X Group error signal 51) BIT 10 X X X Group warning signal 49) BIT 9 X X X Group fault signal 49) BIT 8 X X X OCTET 10 BIT 7 "Tripped" signal not acknowledged52) BIT 6 X X X Electrical closing lockout BIT 5 X X X BI ...
Communication System Manual
3WN6 Circuit-Breakers Version 1.0 (05/98) Copyright Siemens AG 1998. All rights reserved. 63 3.5.3 STEP 5 program The function and data blocks required for utilizing the full scope of communication are supplied on diskette. An example illustrates how these blocks are integrated in an existing S5 program and how they are adapted in line with local conditions. Attention: The following versions are required if the program is to function properly: • 3WN6 interface module: old hardware version (PROFIBUS outgoing circuit on base) 2, new hardware version (PROFIBUS o ...
Communication System Manual
3WN6 Circuit-Breakers Version 1.0 (05/98) Copyright Siemens AG 1998. All rights reserved. 59 3.5 Description of software block required for utilizing communication functions with SIMATIC S5 and S7 3.5.1 CPU and DP master types IM308C CP5431 itself CP342-5DP CP443-5DP IM467 941 ¨ ¨ 942 ¨ ¨ 943 ü ü 944 ü ü 945 ü ü 922 ¨ ¨ 928 ¨ ¨ 928B ü ü 946/947 ü ü 948 ¨ ¨ 313 ¨ 314 ¨ 315 ¨ 315-2DP ¨ ¨ 412 ¨ ¨ 413 ¨ ¨ 413-2DP ¨ ¨ ¨ 414 ¨ ¨ 414-2DP ¨ ¨ ¨ 416 ¨ ¨ 416-2DP ¨ ¨ ¨ ü Tested ¨ Planned, but assessment not yet finalized. Not pl ...
Communication System Manual
3WN6 Circuit-Breakers Copyright Siemens AG 1998. All rights reserved. Version1.0 (05/98) 28 Software: - 3.5" diskette with type/GSD file for the software connection of 3WN6 to PROFIBUS-DP (bus configuration). This diskette (no. 2b) is supplied with the interface. Step 6, page 34 outlines which file is to be used for which master. - Bus master software for communication control. In order to communicate with the SIMATIC S5/S7 as bus master, a standard software block (no. 5) is required (see page 59 for a description of this module): Order number: 3RK1800-0AA00- ...
Communication System Manual
3WN6 Circuit-Breakers Version 1.0 (05/98) Copyright Siemens AG 1998. All rights reserved. 71 3.5.3.6 Extract from program listing of supplied example 3.5.3.6.1 DB80 DB80 C:BS3WN6ST.S5D LAE=261 /514 3WN6 ASSIGNMENT TO MESSAGE GROUP 0 Sheet 1 0: KF = +00000; 1: KY = 000,000; 2: KF = +00500; 0:01 TEST UNIT+DELIVERY DATE 3: KY = 001,000; 4: KF = +00500; 0:02 IDENTIFIER NUMBER 5: KY = 002,000; ...
Communication System Manual
3WN6 Circuit-Breakers Copyright Siemens AG 1998. All rights reserved. Version1.0 (05/98) 46 T-Nr. RELEASE N and P H and J/K D and E/F Message address 1:8 Fault messages 32) 748, 1, 0 (Only with communication module with measurement functions (Z=F05)) The input of octet strings OS1 to OS4 is not required for the message address in this case. OS1:7 Underfrequency OS1:6 X Overfrequency OS1:5 X Reversal of direction of power flow OS1:4 X Overvoltage OS1:3 X Voltage phase imbalance OS1:2 X Undervoltage OS1:1 X Current phase imbalance (Fine settings 5 - 50 %) OS1:0 ...
Communication System Manual
3VF Circuit-Breakers Copyright Siemens AG 1998. All rights reserved. Version1.0 (05/98) 16 Legend for wiring diagrams a) and b) 1.) SIMOCODE-DP input: not connected (NC) 2.) SIMOCODE-DP input for indicating circuit-breaker state "OFF" 3.) SIMOCODE-DP input for indicating circuit-breaker state "ON" 4.) SIMOCODE-DP input for indicating circuit-breaker state "Tripped" 5.) SIMOCODE-DP output: internal 24 V voltage supply for inputs 6.) SIMOCODE-DP input for 230 V AC operating voltage for motorized operating mechanism. Note: If rated voltages < 230 V are required ...
Siemens 3VF Series user guide recommended for: TSP-XC, 3WX3641- JD00 Series, 3WN6, 3KF1 Series, Sentron LMD6 Series.
⚠️ Download Safety
The Circuit breakers Communications manual (114 pages) is completely safe to download (last scan date: 06/05/2026).
Related PDF Instructions for Siemens 3VF Series:
-
Siemens BB-55 Enclosure Installation instructions
BB-552 -
Siemens SIMATIC NET PS598-1 Power Supply Compact operating instructions
SIMATIC NET PS598-124 -
Siemens GGA Series Controller Mounting instructions
GGA Series8 -
Siemens 2011 Cordless Telephone Operating instructions manual
2011114 -
Siemens SIMATIC HMI IRD400 Monitor Operating instructions manual
SIMATIC HMI IRD40054 -
Siemens KD40NX73 Freezer User manual manual
KD40NX7392
Circuit breakers Equipment: Frequently Requested
-
Siemens SINAMICS S120 Power Supply
19.04.2026User instruction booklet for the Siemens SINAMICS S120 Power Supply. This guide explains the features and usage procedures, control functions, network setup.SINAMICS S120, 46 -
Puls DIMENSION PISA-B-8CL2-B4 Control Unit
19.11.2025Essential instructions for the Puls DIMENSION PISA-B-8CL2-B4 Control Unit. It describes step-by-step technical guidelines, warranty information, adjustment procedures, performance guidelines.DIMENSION PISA-B-8CL2-B4, 3 -
Eaton Ulusoy URING12-24-LLC-SF6 Circuit breakers
11.11.2025Manual for safe operation of the Eaton Ulusoy URING12-24-LLC-SF6 Circuit breakers. It includes maintenance procedures and installation, performance details, safety protocols, shutdown procedures.Ulusoy URING12-24-LLC-SF6, 26 -
Alpha XM2 Series Circuit breakers
07.03.2026Professional user manual for the Alpha XM2 Series Circuit breakers. This reference manual outlines hardware components, adjustment procedures, assembly reference, product handling.XM2 Series, 2 -
GE A Series Pro-Stock THQB Circuit breakers
29.01.2026User and installation guide for the GE A Series Pro-Stock THQB Circuit breakers. The manual covers procedures for error handling, installation support, safety protocols, firmware updates.A Series Pro-Stock THQB, 10 -
Eaton NZM1-XFIU Circuit breakers
05.03.2026Device setup guide for the Eaton NZM1-XFIU Circuit breakers. This reference manual outlines product handling, installation steps, replacement parts, interface navigation.NZM1-XFIU, 10
Have some Questions about Siemens 3VF Series Device?
Get valuable and actionable advices from other Siemens 3VF Series device users. Describe your problem or question, regarding the using of 3VF Series, in as much detail as possible, and other users will be able to answer you.