Pulsar INTRE Manual
Text of the manual
Edition: 2 from 05.12.2013
Supercedes edition: 1 from 06.01.2013
1. General description. ................................................................................................................................ 3
2. Components arrangement....................................................................................................................... 3
3. Installation. ..........
operating in the ETHERNET network
•
compliance with the IEEE 802.3 standard
•
10/100BaseT physical layer
•
transmission speed 10/100Mbps (auto-sensing)
•
full-duplex or half-duplex operation (auto-sensing)
•
built-in web server for configuration
•
data encryption: DES, 3DES, AES
•
supports many popular protoc
Table 1. Description of the components.
Component No.
Description
[1]
LEDs – optical indication:
PWR – supply’s voltage
TX
– data transmission
RX
– receiving data
[2]
RST button
– reset the interface settings
[3]
INIT button
– initialization of the interface
[4]
RJ45 Ethernet Interface Socket (see Table 2)
[5]
RS485 hu
3.4 Installation of the interface.
1. Lead the cable of the RS485 bus through the cable gland and the appropriate hole in the enclosure and then
connect to the RS485 connector of the interface. The A+, B- cables should be connected the same way as the
rest of devices (A+ to A+, B- to B-) In case of shielded wires, the shield should be c