OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 3 INDEX 1 1 TECHNICAL SUMMARY ........................................................................................................ 5 1.1 BRIEF DESCRIPTION ............................................................................................................ 5 1.1.1 OVERVIEW ......................................................................................................................... 5 1.1.2 APPLICATIONS .................................................................................................................. 5 1.1.3 FEATURES AND BENEFITS ............................................................................................. 5 1.2 TYPICAL CONFIGURATION ................................................................................................ 6 1.3 TECHNICAL SPECIFICATIONS ........................................................................................... 7 1.4 FRONT PANEL ....................................................................................................................... 8 2 INSTALLATION AND OPERATION ..................................................................................... 9 2.1 INTRODUCTION .................................................................................................................... 9 2.2 INSTALLATION ..................................................................................................................... 9 2.2.1 WARNING AND PRECAUTIONS ..................................................................................... 9 2.2.2 OSD2155 DRAWINGS AND DIMENSIONS ................................................................... 10 2.2.3 POWER SUPPLY CONNECTIONS ................................................................................. 10 2.2.4 LOCATION ........................................................................................................................ 11 2.2.5 FIXED RJ45 COPPER PORT PIN ASSIGNMENTS ........................................................ 11 2.2.6 FITTING SFP CONNECTORS.......................................................................................... 11 2.2.7 LED INDICATORS ........................................................................................................... 12 2.2.8 CONTROLS ....................................................................................................................... 13 2.2.9 BASIC CONNECTIONS ................................................................................................... 14 2.3 LINK LOSS FORWARDING ................................................................................................ 15 3 MAINTENANCE...................................................................................................................... 18 3.1 INTRODUCTION .................................................................................................................. 18 3.2 EXTERNAL INSPECTION ................................................................................................... 18 3.3 ROUTINE MAINTENANCE ................................................................................................. 18 4 WARRANTY ............................................................................................................................ 19 4.1 WARRANTY PERIOD .......................................................................................................... 19 4.2 REPAIRS ................................................................................................................................ 19 4.2.1 WARRANTY REPAIRS .................................................................................................... 19 4.2.2 OUT-OF-WARRANTY REPAIRS .................................................................................... 19 4.2.3 SITE REPAIRS .................................................................................................................. 19 4.2.4 EXCLUSIONS ................................................................................................................... 19

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 4 FIGURE 1: OSD2155 TYPICAL CONFIGURATIONS ......................................................................... 6 FIGURE 2: OSD2155 CONNECTORS ................................................................................................... 8 FIGURE 3: DIMENSIONS .................................................................................................................... 10 FIGURE 5: POWER SUPPLY CONNECTIONS .................................................................................. 10 FIGURE 6: FIXED RJ45 ETHERNET CONNECTORS ....................................................................... 11 FIGURE 9: FITTING/REMOVING SFP CONNECTORS ................................................................... 11 FIGURE 7: LED INDICATORS ............................................................................................................ 12 FIGURE 8: OSD2155 3-WAY DIP SWITCH ....................................................................................... 13 FIGURE 10: BASIC CONNECTIONS .................................................................................................. 14 FIGURE 10: LINK LOSS FORWARDING FUNCTION ..................................................................... 15 FIGURE 11: COPPER CONNECTION LOSS ...................................................................................... 17 FIGURE 12: FIBER CONNECTION LOSS .......................................................................................... 17 TABLE 2: TECHNICAL SPECIFICATIONS ......................................................................................... 7 TABLE 3: POWER SUPPLY PINOUT ................................................................................................. 10 TABLE 4: LED FUNCTION ................................................................................................................. 12 TABLE 5: 4-WAY DIP SWITCH SETTINGS ...................................................................................... 13 TABLE 5: CONFIGURATION WITH LLF ENABLED ...................................................................... 16 TABLE 6: CONFIGURATION WITH LLF DISABLED ..................................................................... 16

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 5 1 TECHNICAL SUMMARY 1.1 BRIEF DESCRIPTION 1.1.1 OVERVIEW The OSD2155 is a 10/100/1000BaseT Ethernet Media Converter supporting Jumbo Frames. It has one RJ45 copper port and one SFP port which can be specified by the user for one or two fiber configuration. The unit will operate on either singlemode or multimode fiber by use of the appropriate optical device. A major benefit of the OSD2155 is its reliable operation over the -20°C to +75°C temperature range which allows it to be used in environments such as roadside cabinets, mine sites and factories. The OSD2155 module is intended for isolated use and requires an external power source. 1.1.2 APPLICATIONS ▲ Any network utilising a mix of copper and fiber ▲ Industrial IP communications ▲ Gigabit Ethernet networks 1.1.3 FEATURES AND BENEFITS ▲ Complies with IEEE802.3i/802.3u/802.3ab 10/100/1000Base-T, IEEE802.3z 1000Base-Lx/Sx standards. ▲ Supports network traffic of 100Mbps or 1000Mbps. ▲ Has one fixed 10/100/1000Base-T copper port and one SFP port which can be 10/100/1000BaseT, 100Base- Fx or 1000BaseLx/Sx/Zx. ▲ Auto MDI/MDIX. ▲ Can be used with either singlemode or multimode fiber over a variety of link budgets ▲ Supports 10KB jumbo frames. ▲ Available for operation over 1 or 2 fibers. ▲ Plugs into OSD’s standard OSD350 and OSD370 3RU 19” rack mounting card frames. ▲ Operates over the temperature range of -20 to +75°C. ▲ Advanced features like Link Loss Forwarding to detect the link status of link partners either on the fiber and/or copper port. ▲ Interoperates with all standard OSD and third parts GbE media converters and switches. ▲ SFP module sold separately.

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 6 1.2 TYPICAL CONFIGURATION Figure 1 below indicates the typical set-up for an OSD2155 system. FIGURE 1: OSD2155 TYPICAL CONFIGURATIONS

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 7 1.3 TECHNICAL SPECIFICATIONS TABLE 1: TECHNICAL SPECIFICATIONS SPECIFICATION PERFORMANCE Electrical Data Interface IEEE802.3i/802.3u/802.3ab 10/100/1000Base-T Ethernet Electrical Data Rate 10, 100, 1000Mbps with energy detect, auto negotiate, auto MDIX Jumbo Frame Support 10KB Optical Data Interface IEEE802.3z 1000Base-Lx/Sx or IEEE802.3u 100BaseFx Optical Data Rate 100Mbps or 1000Mbps Operating Mode Half or full duplex for 10/100 Full duplex for 1000 Flow control Electrical Data Connector RJ45 Controls Program 100 or 1000Mbps on fiber Link Loss Forwarding: On or Off Fault Detection: Fiber only or copper and fiber Optical Port Connector SFP SFP Options Short haul, long haul, single fiber operation, etc Please consult OSD datasheet #1021000XX or contact OSD Operating Temperature -20°C to +75°C Relative Humidity 0 to 95% non-condensing Power Requirements +11VDC to +13VDC supplied via the card frame backplane Dimensions (mm) 25W x 169D x 100H Weight 0.2kg Chassis Current Consumption (CCC) 0.25 Amp 102215502

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 8 1.4 FRONT PANEL The front panel consists of one fixed copper port for 10/100/1000Base-T, one SFP port, a 4-way DIP switch and a Mini USB port. The SFP device is sold separately giving the user choice to use either one or two fiber communications with various optical power outputs depending on the distance required. Each section will be described further throughout this manual. FIGURE 2: OSD2155 CONNECTORS Fixed RJ45 Copper Port SFP Port 4-Way DIP Switch Mini USB Connector

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 9 2 INSTALLATION AND OPERATION 2.1 INTRODUCTION This section outlines the methods required to install and operate the OSD2155 successfully. It should be studied carefully if damage to the equipment or poor results are to be avoided. This equipment has been fully tested prior to dispatch and is ready for immediate operation. However it is advisable to check for external transportation damage before operation. If damage is evident, return the unit with the packaging to your supplier immediately. 2.2 INSTALLATION 2.2.1 WARNING AND PRECAUTIONS ▲ ELECTROMAGNETIC COMPATIBILITY WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. ▲ OPTICAL OUTPUT OPERATION WARNING: Laser Safety: Class 1 Laser Product per IEC/EN 60825-1:2014 standard. Class 1 The OSD2155 is a Class 1 laser product when SFP fitted PRECAUTIONS ▲ All service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures during servicing of equipment ▲ Areas where laser products are installed should be restricted in access to trained service personnel only and appropriate warning signs posted in the work area. ▲ All laser apertures should be covered by protective covers when not connected to optical fibers. Never leave outputs uncovered. ▲ Laser equipment should be positioned above or below eye level where possible. Apertures should be positioned away from personnel. ▲ Protective eyewear should be worn in the vicinity of laser equipment.

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 10 2.2.2 OSD2155 DRAWINGS AND DIMENSIONS The standard OSD2155 is designed to be mounted and powered from either the OSD350 or OSD370 19” 3RU Chassis. FIGURE 3: DIMENSIONS 2.2.3 POWER SUPPLY CONNECTIONS The OSD2155 requires external DC power. The voltage range of the OSD2155 is +11VDC to +13VDC. Which is powered from the OSD370 or OSD350 chassis. DC power is connected via the DB9 connector. The OSD2155 should be fixed into the chassis using the captivated screws. The OSD2155 can be plugged in or out of the chassis with power on or off. TABLE 2: POWER SUPPLY PINOUT OSD370 or OSD350 Power Pin Specification Pin 3 +12VDC (±1V) – supplied by OSD921 Pin 6,7 0V FIGURE 4: POWER SUPPLY CONNECTIONS 25 169 100 5 1 6 9

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 11 2.2.4 LOCATION As with any electrical device, the OSD2155 together with the OSD370/OSD350 chassis should be placed where the unit will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site selected should meet the following requirements: • The ambient temperature should be between -20°C to 75°C (-4°F to 167°F). • The relative humidity should be less than 95 percent, non-condensing. • Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards. • Make sure that the switch receives adequate ventilation. Do not block or obstruct the ventilation holes on the chassis. 2.2.5 FIXED RJ45 COPPER PORT PIN ASSIGNMENTS Figure 5 shows the pin configuration for the fixed RJ45 copper port. FIGURE 5: FIXED RJ45 ETHERNET CONNECTORS 2.2.6 FITTING SFP CONNECTORS Care should be taken when inserting/removing the SFP connectors from the SFP port as SFP modules are Electrostatic (ES) sensitive and Electrostatic Discharge (ESD) precautions should be taken when installing. Ensure that the SFP is fully engaged and latched into position. Inserting SFP – Ensure that the SFP lever is in the locked position and insert into appropriate SFP port. Gently push the SFP until it locks into place. Remove plastic/rubber dust cap and fit appropriate fiber cable. Removing SFP – Remove fiber connector. Pull the SFP lever down to unlock SFP from housing. Using the lever, gently pull the SFP out. Fiber SFP FIGURE 6: FITTING/REMOVING SFP CONNECTORS 1: Bidirectional Data A+, DC+ 2: Bidirectional Data A-, DC+ 3: Bidirectional Data B+, DC- 4: Bidirectional Data C+, DC+ 5: Bidirectional Data C-, DC+ 6: Bidirectional Data B-, DC- 7: Bidirectional Data D+, DC- 8: Bidirectional Data D-, DC- LINK/ACT SPD 8 7 6 5 4 3 2 1 Fixed Copper Port Inserting SFP Removing SFP 1 2

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 12 2.2.7 LED INDICATORS FIGURE 7: LED INDICATORS TABLE 3: LED FUNCTION FUNCTION Indicator On LED Colour Off Blinking  Spd Copper Speed 1Gbps Green 10/100Mbps -  Lnk/Act Copper Link Activity Amber No Copper Link Activity  Power Power On Green Power Off -  Lnk/Act/Spd Fiber Speed 100Mbps Amber No Optical Link Activity 1Gbps Green    

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 13 2.2.8 CONTROLS The OSD2155 has a 4-way DIP switch to control a number of functions. Figure 8 outlines the function of each switch. For correct operation, set the required switch settings before powering the unit. The OSD2155 also has a reset switch located on the rear panel. Press this button momentarily to reset the unit. FIGURE 8: OSD2155 3-WAY DIP SWITCH TABLE 4: 4-WAY DIP SWITCH SETTINGS SWITCH NUMBER DESCRIPTION SWITCH POSITION FUNCTION 1 Function OFF User Mode* ON Programming Mode 2 Optical Port Speed OFF 1000BASE-X* ON 100BASE-X 3 LLF Enable/Disable OFF LLF Disable* ON LLF Enable 4 LLF Detection OFF Fiber and Copper* ON Fiber Only * Default settings. ON Position OFF Position 1 2 3 4

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 14 2.2.9 BASIC CONNECTIONS Figure 10 shows basic user connections to the OSD2155. FIGURE 9: BASIC CONNECTIONS Ethernet cable SFP Fiber cable

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 15 2.3 LINK LOSS FORWARDING Figure 10 is a flow chart of the OSD2155 Link Loss Forwarding (LLF) function and operation. FIGURE 10: LINK LOSS FORWARDING FUNCTION

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 16 The following tables outline the recommended switch settings for the OSD2155. Any changes in switch settings require power up to take effect. TABLE 5: CONFIGURATION WITH LLF ENABLED Configurations Case1 Case2 Case3 Case4 Switch Setting Configurations 1. LLF detects fiber & copper 2. LLF is enabled 3. Fiber port is 100BASE-X 1. LLF detects fiber & copper 2. LLF is enabled 3. Fiber port is 1000BASE-X 1. LLF detects fiber only 2. LLF is enabled 3. Fiber port is 100BASE-X 1. LLF detects fiber only 2. LLF is enabled 3. Fiber port is 1000BASE-X Fiber link loss Response Action Disable Tx of copper port Disable Tx of copper port Restore Sequence 1. Fix fault and reconnect 2. Wait for link to be reestablished 1. Fix fault and reconnect 2. Wait for link to be reestablished Copper link loss Response Action Disable Tx of fiber port NULL Restore Sequence 1.Fix fault and reconnect 2.Wait for link to be reestablished NULL TABLE 6: CONFIGURATION WITH LLF DISABLED Configurations Case1 Case2 Switch status Configurations of SIP switch 1. Invalid 2. LLF is disabled 3. Fiber port is 1000BASE-X 1. Invalid 2. LLF is disabled 3. Fiber port is 1000BASE-X 1. Invalid 2. LLF is disabled 3. Fiber port is 100BASE-X 1. Invalid 2. LLF is disabled 3. Fiber port is 100BASE-X Fiber link loss Response Action NULL NULL Restore Sequence NULL NULL Copper link loss Response Action NULL NULL Restore Sequence NULL NULL 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 17 Examples Figure 11 is an example of a copper connection loss. The OSD2155 will detect that there is no copper connection received and then disable the transmission to the fiber port. The 1000Base-X switch will thus be notified that there has been a copper link loss. FIGURE 11: COPPER CONNECTION LOSS Figure 12 is an example of a fiber connection loss. If the OSD2155 does not receive a valid optical signal from the switch, transmission to copper port will be disabled. FIGURE 12: FIBER CONNECTION LOSS OSD2155 1000Base-X Switch Switch or PC Fiber Copper Tx Rx Tx Tx Tx Rx Rx Rx OSD2155 1000Base-X Switch Switch or PC Fiber Copper Tx Rx Tx Tx Tx Rx Rx Rx

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 18 3 MAINTENANCE 3.1 INTRODUCTION The following section outlines the fault-finding procedure for the OSD2155 modems. Please take note of the following: ▲ Personnel without appropriate training should not attempt any maintenance except that outlined below. ▲ If further maintenance is attempted you are warned that every care should be taken to ensure that internal measurements made while the equipment is operational are taken carefully as some components within the unit are expensive and may be damaged by failure of any portion of their support circuitry. ▲ Some components within the unit are Electrostatic (ES) sensitive and Electrostatic Discharge (ESD) precautions should be taken when performing maintenance upon the unit. 3.2 EXTERNAL INSPECTION Visually check for the following: ▲ Check that the correct power source is connected to the power socket. ▲ Check that the Ethernet cables are connected to the modem correctly and that the PSE power requirements do not exceed the OSD2155 modems maximum PD power. ▲ Inspect the optical connectors (fiber SFP) for any contamination and clean using isopropyl alcohol and a lint free tissue if any contamination is detected. 3.3 ROUTINE MAINTENANCE ▲ There is no routine maintenance required with the OSD2155.

OPTICAL SYSTEMS DESIGN

DOC ID: 10117401 OSD2155 OPERATOR MANUAL PAGE 19 4 WARRANTY Thank you for purchasing equipment designed, manufactured and serviced by Optical Systems Design (OSD). OSD warrants that at the time of shipment, its products are free from defects in material and workmanship and conforms to specifications. Our Warranty conditions are outlined below: 4.1 WARRANTY PERIOD For warranty period, please call your local OSD distributor. 4.2 REPAIRS Optical Systems Design reserves the right to repair or replace faulty modules/units. Please obtain a “Return Material Authorisation” (RMA) form and number before returning goods. Goods must be returned in adequate packing material to Optical Systems Design, Warriewood or its nominated authorised representative, for all repairs. 4.2.1 WARRANTY REPAIRS Return shipments to OSD shall be at customer's expense and freight back to the customer will be at OSD expense. 4.2.2 OUT-OF-WARRANTY REPAIRS OSD reserves the right to repair or replace any faulty goods. Freight costs and insurance for both journeys are met by the user. All equipment repaired by OSD will have a 3-Month Warranty from the date of dispatch. 4.2.3 SITE REPAIRS By agreement site repairs may be undertaken for which out of pocket, hotel and travel expenses will be charged. 4.2.4 EXCLUSIONS This warranty does not apply to defects caused by unauthorized modifications, misuse, abuse or transport damage to the equipment. All modifications to OSD’s standard product will need written authorization and will be charged at normal repair rates. All modifications are to be carried out by OSD Technicians. Warranty is void if unauthorized removal and/or tampering with serial number and/or repair labels is evident.

Optical Systems Design Pty. Ltd.

7/1 Vuko Pl. Warriewood 2102 P.O. Box 891 Mona Vale N.S.W. Australia 2103 Telephone: +61 2 9913 8540 Facsimile: +61 2 9913 8735 Email: [email protected] Web Site: www.osd.com.au OPTIC L SYSTEMS DESIGN PTY LTD A.B.N. 83 003 020 504 Printed in Australia